Inductance Reaktansi No x mm2 Ω/km Ω/km mH/km Ω/km Air A 3 X 35 0.524 0.668 0.395 0.79203 190 3 X 50 0.387 0.494 0.379 0.05878 226 3 X 70 0.268 0.342 0.357 0.03833 280 3 X 95 0.193 0.247 0.341 0.02644 338 3 X 120 0.153 0.196 0.328 0.02018 387 3 X 150 0.124 0.159 0.318 0.01587 437 3 X 185 0.0991 0.128 0.308 0.01237 497 3 X 240 0.0754 0.098 0.296 0.0091 580 3 X 300 0.0601 0.079 0.287 0.00711 655 Keterangan simulator: Disimulasikan fungsi SUTM dengan: = 0,2104 ohm/fasa/km R = 2,1042 ohm/fasa R = 4,2084 ohm/fasa = 1,0047 mH/fasa/km L = 10.047 mH/fasa L = 20,094 mH/fasa Disimulasikan fungsi SKTM dengan : = 0,12546875 ohm/fasa/km = 0.125 ohm/fasa/km R = 0,53125 ohm/fasa R = 1,0625 ohm/fasa Num. of Cores and Nominal Cross Section Conductor DC Resistance at 20⁰C Conductor AC Resistance at 20⁰C Max. Current Ca at 30 Ø Saluran Udara Tegangan Menengah (SUTM) - Panjang saluran 20 Km - Penghantar AAAC (All Alumunium Alloy Conductor) 150 mm2 - - Ø Saluran Kabel Tegangan Menengah (SKTM) - Panjang saluran 8,5 km - Salah satu jenis kabel tanah XLPE yaitu kabel NA2XSEFGbY 3 x 240 mm2 -

description

DATA KABEL

Transcript of Data Kabel a3c,Na2xsefgby, Dan n2xseby

Page 1: Data Kabel a3c,Na2xsefgby, Dan n2xseby

Inductance Reaktansi

No x mm2 Ω/km Ω/km mH/km Ω/km Air A3 X 35 0.524 0.668 0.395 0.79203 1903 X 50 0.387 0.494 0.379 0.05878 2263 X 70 0.268 0.342 0.357 0.03833 2803 X 95 0.193 0.247 0.341 0.02644 3383 X 120 0.153 0.196 0.328 0.02018 3873 X 150 0.124 0.159 0.318 0.01587 4373 X 185 0.0991 0.128 0.308 0.01237 4973 X 240 0.0754 0.098 0.296 0.0091 5803 X 300 0.0601 0.079 0.287 0.00711 655

Keterangan simulator:

Disimulasikan fungsi SUTM dengan:

= 0,2104 ohm/fasa/kmR = 2,1042 ohm/fasaR = 4,2084 ohm/fasa

= 1,0047 mH/fasa/kmL = 10.047 mH/fasaL = 20,094 mH/fasa

Disimulasikan fungsi SKTM dengan :

= 0,12546875 ohm/fasa/km= 0.125 ohm/fasa/km

R = 0,53125 ohm/fasaR = 1,0625 ohm/fasa

Num. of Cores and Nominal Cross Section

Conductor DC Resistance at

20⁰C

Conductor AC Resistance at

20⁰C

Max. Current Carrying Capacity at 30 C⁰

Ø Saluran Udara Tegangan Menengah (SUTM)

- Panjang saluran 20 Km- Penghantar AAAC (All Alumunium Alloy Conductor) 150 mm2- R(AC)

- L

Ø Saluran Kabel Tegangan Menengah (SKTM)

- Panjang saluran 8,5 km- Salah satu jenis kabel tanah XLPE yaitu kabel NA2XSEFGbY 3 x 240 mm2- R(AC)

Page 2: Data Kabel a3c,Na2xsefgby, Dan n2xseby

= 0.302 mH/fasa/kmL = 1,2835 mH/fasa/kmL = 2,567 mH/fasa

= 0,307 µF/fasa/kmC = 2,6095 µF/fasaPemasangan C dibagi dua di tiap fasa sehingga,c = 1,30475 MF/fasa

- L

- C

Page 3: Data Kabel a3c,Na2xsefgby, Dan n2xseby

shor circuit current at 1 sec

conductor screen

Pipe A max max mm kg/km174 5.01 1.03 56.5 4.322205 7.15 1.03 59 4.883250 10.01 1.03 63 5.836298 13.59 1.37 66.5 6.905338 17.16 1.37 70 7.907378 21.45 1.37 74 9.096426 26.46 1.37 77.5 10.488488 34.32 1.37 84.5 13.454545 42.9 1.37 89.5 15.722