Perkin-Elmer Corporation

1
Perkin-Elmer extends the whole field of Thermal Analysis with the new DSC-2 Differential Scanning Calorimeter. Model DSC-2 Basic Unit 3 IR.O- I ·*Φ (••Ρ) ' ·*. —* Perkin-Elmer now announces the Model DSC-2, a Differential Scan- ning Calorimeter so technically ad- vanced that it establishes a totally new standard of performance in quantitative thermal analysis. It's based on the same patented oper- ating principles* as our innovative Model DSC-1B but redesigned in every way to satisfy the needs of the most demanding thermal analyst. The Model DSC-2 provides the ultimate in data quality and in- cludes at least "order-of-magni- tude" improvements in every important operating parameter and feature. Widest Temperature Range available in quantitative thermal analysis, 100°Kto 1000°K (-175°C to 725°C) with automated digital programmer including temperature limits precisely settable at 0.1° intervals. Higher Baseline Quality. Essenti- ally straight and repeatable base- lines under all practical operating conditions. Difficult specific heat measurements now routine over the whole temperature range. Unprecedented Sensitivity. To 0.1 millical/sec full scale (0.01 mill ical/sec/inch) providing greater range of selection of sample size, scanning rate and sensitivity for maximum resolution with noise-free baselines. Practically Instantaneous Tem- perature Response for rapid scan- ning and isothermal equilibrium. Already an exclusive capability of Perkin-Elmer systems but further enhanced with a novel automatic circuit that cancels program tran- sients and thermal lags. Precisely Linear Temperature Calibrations, for example, maxi- mum deviation from perfect linear- ity from 50°C to 725°C is less than 1.0°C simplifying precise tempera- ture determination and insuring the accuracy and constancy of scan- ning rates over wide ranges. Many other features and speci- fications reflect the care, thought and uncompromising engineering that have gone into the Model DSC-2. These, together with Perkin-Elmer's patented direct calorimetric readout system, make the Model DSC-2 the only choice for the thermal analyst who needs the best there is. See the Model DSC-2 at the Pitts- burgh Conference, or write for full details to Perkin-Elmer Corpora- tion, Instrument Division, 702 Main Avenue, Norwalk, Conn. 06856. Model DSC-2 for sub-ambient work PERKIN-ELMER " NO. 3263484 CIRCLE 158 ON READER SERVICE CARD 76 A · ANALYTICAL CHEMISTRY, VOL. 44, NO. 3, MARCH 1972

Transcript of Perkin-Elmer Corporation

Page 1: Perkin-Elmer Corporation

Perkin-Elmer extends the whole field of Thermal Analysis with the new DSC-2 Differential Scanning Calorimeter.

Model DSC-2 Basic Unit

3 IR.O-

I ·*Φ

(••Ρ) ' ·*. —*

Perkin-Elmer now announces the Model DSC-2, a Differential Scan­ning Calorimeter so technical ly ad­vanced that it establishes a totally new standard of performance in quantitative thermal analysis. It's based on the same patented oper­at ing pr inciples* as our innovative Model DSC-1B but redesigned in every way to satisfy the needs of t h e m o s t d e m a n d i n g t h e r m a l analyst. The Model DSC-2 provides the ult imate in data quality and in­cludes at least "order-of-magni-t u d e " i m p r o v e m e n t s in e v e r y important operating parameter and feature. • W i d e s t T e m p e r a t u r e R a n g e avai lab le in quant i ta t ive thermal analysis, 100°Kto 1000°K ( - 1 7 5 ° C to 725°C) with automated digital programmer including temperature limits precisely settable at 0.1° intervals. • Higher Baseline Quality. Essenti­ally straight and repeatable base­lines under all practical operating

condit ions. Difficult specif ic heat measurements now routine over the whole temperature range. • Unprecedented Sensitivity. To 0.1 mi l l ica l /sec full scale (0.01 m i l l i c a l / s e c / i n c h ) p r o v i d i n g g r e a t e r r a n g e o f s e l e c t i o n o f sample size, scann ing rate and sensitivity for maximum resolution with noise-free baselines. • Practically Instantaneous Tem­perature Response for rapid scan­ning and isothermal equi l ibr ium. Already an exclusive capabil i ty of Perkin-Elmer systems but further enhanced with a novel automatic circui t that cancels program t ran­sients and thermal lags. • Precisely Linear Temperature Calibrations, for example, maxi­mum deviation from perfect linear­ity from 50°C to 725°C is less than 1.0°C simplifying precise tempera­ture determination and insuring the accuracy and constancy of scan­ning rates over wide ranges.

Many other features and speci­

f icat ions reflect the care, thought and uncompromising engineering that have gone into the Model D S C - 2 . T h e s e , t o g e t h e r w i t h P e r k i n - E l m e r ' s pa ten ted d i r ec t calorimetr ic readout system, make the Model DSC-2 the only choice for the thermal analyst who needs the best there is.

See the Model DSC-2 at the Pitts­burgh Conference, or write for full details to Perkin-Elmer Corpora­t ion, Instrument Division, 702 Main Avenue, Norwalk, Conn. 06856.

Model DSC-2 for sub-ambient work

PERKIN-ELMER " NO. 3263484

CIRCLE 158 O N READER SERVICE CARD

76 A · ANALYTICAL CHEMISTRY, VOL. 44, NO. 3, MARCH 1972