Arreiners/geos474-574/GT19 K-Ar and Ar-Ar 1.pdf40. Ca (n,n. α) 36. Ar • especially important for...

Post on 24-Mar-2021

4 views 0 download

Transcript of Arreiners/geos474-574/GT19 K-Ar and Ar-Ar 1.pdf40. Ca (n,n. α) 36. Ar • especially important for...

40Ar* = 40Artot - 36Ar (40Ar/36Ar)air- [38Ar (40Ar/38Ar)spk]

(40Ar/36Ar)air = 298.7 ± 0.1(used to be 295.5)

Swindle et al., 1995

40Ar/39Ar

main advantages:1. measurement of P and D in same aliquot2. get domain/zonation information

3919K(n,p)39

18Ar

or

3919K + 10n → 39

18Ar + 11H

neutrons have to be "fast"...(high E, >~0.1 MeV)

Φ (ε) = flux density of neutrons of energy εσ (ε) = capture cross-section of neutrons of energy ε∆ t = duration of irradiation

[=] (nV)/(cm2s)[=] barns

where ts is age of standard

so, for an unknown...

measured on standard

40K (n,p) 40Ar40Ca (n,nα) 36Ar42Ca (n,α) 39Ar

can minimize to some degree by positioning in reactor......but in reality need to make corrections.

40K (n,p) 40Ar

irradiate a sample with high K and no Ar (e.g., K2SO4 or K-doped glass), then measure 40Ar in it. Then correction

(40Ar/39Ar)K = (40Ar/39Ar)m - (36Ar/39Ar)m (40Ar/36Ar)air

or

(40Ar/39Ar)K = (40Ar/39Ar)m - (36Ar/39Ar)m x 298.6

as measured in the K-doped glass

40Ca (n,nα) 36Ar

• especially important for samples with high Ca/K, like hornblende, plagioclase

• critical because 36Ar is used for atmospheric contamination• related reaction also makes 37Ar

40Ca (n,nα) 36Ar40Ca (n,α) 37Ar

So, just irradiate CaF2, and measure

(36Ar/37Ar)Ca = (36Ar/37Ar)m - (40Ar/37Ar)m (36Ar/40Ar)air

or

(36Ar/37Ar)Ca = (36Ar/37Ar)m - (40Ar/37Ar)m x 1/298.6

as measured in the CaF2

but be careful, because 37Ar has t1/2 ~ 35 days!

42Ca (n,α) 39Ar

in Ca salt, both 39Ar and 37Ar are produced from Ca, so (39Ar/37Ar)Ca is a direct measurement on the Ca-salt

40Ar*/39ArK = (40Ar/39Ar)m - 298(36Ar/39Ar)m+298(36Ar/37Ar)Ca(37Ar/39Ar)m

1-(39Ar/37Ar)Ca(37Ar/39Ar)m

-[40Ar/39Ar]K

• atmospheric correction• 36Ar from 40Ca during irradiation• 39Ar from 42Ca during irradiation• 40Ar from 40K during irradiation

also• need to adjust all values for mass discrimination effects• need to recognize that extraterrestrial samples have different atmospheric

compositions (and cosmogenic ones)

other reactions to worry about

1) 35Cl (n,γ) 36Cl → 36Ar t1/2 = 300,000 a2) 37Cl (n,γ) 38Cl → 38Ar t1/2 = 37.3 min

1) If you have high Cl/Ar samples (e.g., hornblende) and wait ~ a year before analyzing them, this can be a few percent problem

2) Will mostly have decayed by time of analysis, so a) can get Cl content of sample (or step) from 38Ar... (often correlated with excess 40Ar)b) can correct for 36Ar from 36Cl (from 35Cl)

Kelley and Wartho, 2000

McDougall & Harrison, 1999

1) Simple, closed-system behavior

plateaux: no single definition, but typically >4-5 steps that agree within 95% confidence and represent >50% of gas released

1) Conventional isochrondispersion of points along line is due to not just different P/D, but also mixing with trapped component and radiogenic Ar

drawbacks to conventional isochron: 1) 36Ar is measured with lowest precision (only 0.337% of Ar, typically)2) "open-ended" (steps with lots of radiogenic 40Ar plot way out and dominate regression, precluding precise determination of trapped component

Inverse isochron

(40Ar*/39Ar)=(1/J)*(elt-1)

Deviations from line can result from 40Ar* loss (e.g., slow cooling or reheating) and/or multiple trapped components.

2. Excess Ar and the Trapped Component

Non-ideal spectrumTrapped component has higher 40Ar/36Ar than atmosphere

2. Excess Ar and the Trapped Component

Being smart about the trapped component MAY allow you insight into complex step-heating spectra

Pattern of step-heating spectrum can identify and mitigate excess 40Ar(sometimes)

1) 35Cl (n,γ) 36Cl → 36Ar t1/2 = 300,000 a2) 37Cl (n,γ) 38Cl → 38Ar t1/2 = 37.3 min

Excess 40Ar and anomalous Cl are often correlated.

3. Open-system complex behavior

Ar can move around in samples prior to to analysis

If this happens via thermally-activated volume diffusion, we can make sense of it.

small anomalously high peak in terrestrial craters 450-480 Ma (Schmitz et al., 2001)

The Ordovician L-chondrite event

most L-chondrites have high-T cooling ages of 465-500 Ma;

peak: 470 ± 6 Ma (Korochantseva et al., 2006)

Swindle, 2014

Ordovician L-chondrite event: The stratigraphic record

Schmitz et al. (2019)

Ordovician L-chondrite event: The fossil meteorite and ET spinel record

Schmitz et al. (2013; 2015)

Ordovician L-chondrite event: Cosmogenic 21Ne in fossil meteorites

Schmitz et al., 2015

Schmitz et al., 2008

Ordovician L-chondrite event: The fossil meteorite and ET spinel record

estimated flux increase ~10-200x