1
22A ANALYTICAL CHEMISTRY THE NEW pnwERMAi TYPiS Π6 and ΊΛΟ FO RLOADSUPTOlKV*| REDESIGNED ^ ^ S FOR IMPROVED PERFORMANCE POWERSTAT variable transformers Types 116 and 216 have been redesigned. It wasn't a mere "face-lifting" operation, although a streamlined appearance has resulted. It has incorporated many of your worthwhile suggestions and the latest technical knowledge of variable transformer design and manufacture. All improvements have been made within the old standard mounting dimensions to conform to your existing panel layouts, assuring easy replacement if desired. JUST A FEW OF THE IMPROVEMENTS New fusing arrangement employed on cord-plug models. Twist-lock holder on side of terminal box gives easy access and simple replacement · New diecast aluminum terminal box on cord-plug models adds strength and longer service. On all models, the new, extra heavy and rugged terminal board of phenolic plastic prevents breakage. Solder-screw terminals arranged for better spacing for quicker, easier and more posi- tive connections. Barriers between terminals reduce short-circuit ha- zards · Heavy-duty "ON-OFF" switch on cord-plug models is in a more convenient position to eliminate interference with input cord and out- put receptacle · Coil and core design provides excellent regulation, high efficiency and conservative rating for both 50 and 60 cycle duty · Polarity identification provided on cord-plug models for requirements involving ground loads. Ratings of Types 116 and 216 remain the same. Type 116 operates from a 115V., 50/60 cycle, 1 phase source to deliver 0-135V., 7.5 amps. Type 216 has an output of 0-270V., 3.0 amps from 230V., 50/60 cycle, 1 phase. As in the past, the current rating is the current available over the entire range of output voltage. There's no need to refer to a graph to determine the allowable current at a specified value of output voltage. Write today for complete details on these completely redesigned POWERSTAT Types 116 and 216. 8010 MEADOW STREET, BRISTOL, CONNECTICUT TYPE 116U For back-of-panel mounting, incor- poration in existing equipment. TYPE 116-2 A ganged assembly for open- delta, three phase or series, single phase connection. TYPE MT116 A motor-driven unit for push- button remote-control operation. THE SUPERIOR ELECTRIC co. BRISTOL, C 0NNECTICUT POWERSTAT VARIABLE TRANSFORMERS . VOLTBOX AC POWER SUPPLIES · STABILISE VOLTAGE REGULATORS

Transcript of THE SUPERIOR ELECTRIC CO.

Page 1: THE SUPERIOR ELECTRIC CO.

22A A N A L Y T I C A L C H E M I S T R Y

THE NEW

pnwERMAi TYPiS Π 6 and ΊΛΟ

F O R L O A D S U P T O l K V * |

REDESIGNED ^ ^ S FOR IMPROVED PERFORMANCE P O W E R S T A T variable transformers Types 116 and 216 have been redesigned. I t wasn' t a mere "face-lifting" operation, al though a streamlined appearance has resulted. I t has incorporated many of your wor thwhi le suggestions and the latest technical knowledge of variable transformer design and manufacture. All improvements have been made wi th in the old standard mount ing dimensions to conform to your existing panel layouts, assuring easy replacement if desired.

JUST A FEW OF THE IMPROVEMENTS

N e w fusing arrangement employed on cord-plug models. Twist-lock holder on side of terminal box gives easy access and simple replacement · N e w diecast a luminum terminal box on cord-plug models adds strength and longer service. On all models, the new, extra heavy and rugged terminal board of phenolic plastic prevents breakage. Solder-screw terminals arranged for better spacing for quicker, easier and more posi­tive connections. Barriers between terminals reduce short-circuit ha­zards · Heavy-duty "ON-OFF" switch on cord-plug models is in a more convenient position to eliminate interference wi th input cord and out­p u t receptacle · Coil and core design provides excellent regulation, h igh efficiency and conservative ra t ing for both 50 and 60 cycle duty · Polarity identification provided on cord-plug models for requirements involving ground loads.

Ratings of Types 116 and 216 remain the same. Type 116 operates from a 115V., 50/60 cycle, 1 phase source to deliver 0-135V., 7.5 amps. Type 216 has an output of 0-270V., 3.0 amps from 230V., 50/60 cycle, 1 phase. As in the past, the current ra t ing is the current available over the entire range of output voltage. There 's no need to refer to a graph to determine the allowable current at a specified value of ou tput voltage.

W r i t e today for complete details on these completely redesigned P O W E R S T A T Types 116 and 216.

8010 MEADOW STREET, BRISTOL, CONNECTICUT

TYPE 116U

For back-of-panel mounting, incor­p o r a t i o n in e x i s t i n g e q u i p m e n t .

TYPE 116-2

A ganged assembly for open-delta, three phase or series, single phase connection.

TYPE MT116

A m o t o r - d r i v e n unit for p u s h ­b u t t o n remote -con t ro l o p e r a t i o n . THE SUPERIOR ELECTRIC co.

BRISTOL, C 0NNECTICUT

POWERSTAT VARIABLE TRANSFORMERS . VOLTBOX A C POWER SUPPLIES · STABILISE VOLTAGE REGULATORS