Power Control Box PRO EN - padcon.com › de › produkte-reader › power...Compatibility of...

2
to implement the requirements of utilities Active power reduction & reactive power compensation, cos(φ) Mains feed-in management depending on utilities requirements Continuous real time value measuring at the feed in point Web interface for control and configuration of the plant control from afar Individual adaptation as required by the customer Power plant controller Power Control Box PRO _ + P Q cosφ AI DI

Transcript of Power Control Box PRO EN - padcon.com › de › produkte-reader › power...Compatibility of...

  • to implement the requirements of utilities

    Active power reduction & reactive power compensation, cos(φ)

    Mains feed-in management depending on utilities requirements

    Continuous real time value measuring at the feed in point

    Web interface for control and confi guration of the plant control from afar

    Individual adaptation as required by the customer

    Power plant controller

    Power Control Box PRO

    _+ P Q

    cosφ

    AIDI

  • Plant controllerPower Control Box PRO

    PADCON GmbHSteigweg 24 / Gebäude 4497318 KitzingenGermany

    Tel.: +49 (0) 9321 2680 - 200Fax: +49 (0) 9321 2680 - 9200E-Mail: [email protected]: www.padcon.de

    IP 65

    General dataSupply voltage 100 - 240 VAC / 47 - 63 Hz, 24VDC (optional)Power consumption < 100 WNumber of inverters 50 stations if controlled with 1 HzCompatibility of inverters SMA, GE, PowerOne, KACO, ABB, others possible upon requestActual value acquisition Power factor cosφ, active power P, reactive power Q, apparent power S, voltage U, current I

    (to be provided by power meter via MODBUS TCP or analog signals)HousingInstallation Outdoor / IndoorUV resistance Yes Material SteelColour scheme GreyMounting WallDimensions & WeightHousing (width/height/depth) 1200/600/250mmWeight Approx. 85kgInput parametersDigital inputs 16/32 DI, 24VAnalog inputs 8 AI, resolution 16 bit, range typ. -10..+10V, -20..+20mA (optional)Active power reduction Max. 6/12 digital inputs (standard), analog setpoint value (optional), IEC 60870-5-101 (optional)Reactive power control Max. 6/12 digital inputs (standard), analog setpoint value (optional), IEC 60870-5-101 (optional)Reactive power control modes Power factor, reactive power, Voltage, characteristic curves (Q(U), cosPhi(U), cosPhi(P))Further digital input parameters EMERGENCY STOP (only message), QU protection (rapid shut down of the inverters)Output parametersDigital outputs 32 DO, 24 VFeedback to network operator 3 modes: Receipt confirmation, control signals transmitted to inverter, setpoint value reached

    (separate for active and reactive power)Feedback of reactive power Max. 6/12 digital outputsFeedback of active power Max. 6/12 digital outputsControlControl of the inverters Direct by Modbus or by bus coupler with analog outputSoftware functionsMonitoring Integration in Padcon monitoring systemConfiguration Setting of all parameters via front panel and configuration files of solar parkGraphic display Control and actual value of crucial variables of the last 1000s, sending daily curves by emailAlerting In the case of a fault, by emailDocumentation Notification in the case of connection errors and network operator company commands by email Watchdog-Timer Self-monitoring of the control program by integrated hardware and automatic reset in tcase of a faultStandardsCE ConformProtection class and ambient conditionsProtection class in accordance with EN60529 IP 65 (dependent on the housing used)Permissible ambient temperature -10°C to +40°CRel. humidity non-condensing 15% to 90%Altitude above sea level (NN) Max. 1000mAdditional propertiesConnection to system communication Optionally by CAT 6 network cable or fibre optic cableAccessories Supplement for the PADCON Sensor Box: Bus coupler and release relayOptional Master Slave operation With main feeder redundancyBase assembly concrete/earth On request