Multi-turn actuators SA 07.1 - AUMA for valve automation VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.60...

2
Multi-turn actuator Motor Type Speed rpm Torque max. Nm Type Power P N (kW) Speed rpm Nominal current 1) I N (A) Current 2) approx. Imax. (A) Starting current I A (A) cos ϕ SA 07.1 4.8 VD00 63-4/30A 0.025 1,680 0.9 0.9 2.2 0.50 6.7 30 VD00 63-4/30A 0.025 1,680 0.9 0.9 2.2 0.50 9.6 VD00 63-4/30 0.045 1,680 0.9 1.1 2.2 0.50 13 VD00 63-4/30 0.045 1,680 0.9 1.1 2.2 0.50 19 VD00 63-2/30 0.09 3,360 1.3 1.3 4.2 0.60 26 VD00 63-2/30 0.09 3,360 1.3 1.3 4.2 0.60 38 AD00 63-4/50 0.18 1,680 2.0 2.4 5.3 0.50 54 AD00 63-4/50 0.18 1,680 2.0 2.6 5.3 0.50 75 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73 108 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73 150 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73 216 25 AD00 63-2/60 0.37 3,360 2.2 2.9 9.6 0.73 SA 07.5 4.8 VD00 63-4/30B 0.046 1,680 0.9 1.8 2.2 0.50 6.7 60 VD00 63-4/30B 0.046 1,680 0.9 1.8 2.2 0.50 9.6 VD00 63-4/45 0.09 1,680 1.3 1.3 3.5 0.49 13 VD00 63-4/45 0.09 1,680 1.3 1.3 3.5 0.49 19 VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.60 26 VD00 63-2/45 0.18 3,360 1.5 2.2 6.6 0.60 38 AD00 63-4/80 0.37 1,680 3.7 4.6 10 0.58 54 AD00 63-4/80 0.37 1,680 3.7 6.1 10 0.58 75 AD00 63-2/80 0.75 3,360 3.7 5.0 20 0.80 108 AD00 63-2/80 0.75 3,360 3.7 5.7 20 0.80 150 AD00 63-2/80 0.75 3,360 3.7 5.7 20 0.80 216 50 AD00 63-2/80 0.75 3,360 3.7 7.0 20 0.80 SA 10.1 4.8 VD00 71-4/35A 0.09 1,680 1.1 1.3 4.4 0.60 6.7 120 VD00 71-4/33A 0.09 1,680 1.1 1.3 4.4 0.60 9.6 VD00 71-4/35 0.18 1,680 2.2 2.4 6.6 0.49 13 VD00 71-4/35 0.18 1,680 2.2 2.6 6.6 0.49 19 VD00 71-2/35 0.37 3,360 3.1 3.7 9.9 0.67 26 VD00 71-2/35 0.37 3,360 3.1 4.2 9.9 0.67 38 AD00 71-4/80 0.75 1,680 5.5 6.6 19 0.64 54 AD00 71-4/80 0.75 1,680 5.5 7.0 19 0.64 75 AD00 71-2/80 1.5 3,360 8.8 11 35 0.70 108 AD00 71-2/80 1.5 3,360 8.8 13 35 0.70 150 AD00 71-2/80 1.5 3,360 8.8 12 35 0.70 216 100 AD00 71-2/80 1.5 3,360 8.8 15 35 0.70 SA 14.1 4.8 VD00 90-8/40 0.18 840 3.9 4.4 9.9 0.45 56.7 250 VD00 90-8/40 0.18 840 3.9 4.4 9.9 0.45 9.6 VD00 90-4/40 0.37 1,680 2.4 3.7 11 0.74 13 VD00 90-4/40 0.37 1,680 2.4 3.9 11 0.74 19 VD00 90-2/40 0.75 3,360 4.2 7.7 20 0.81 26 VD00 90-2/40 0.75 3,360 4.2 8.3 20 0.81 38 AD00 90-4/75 1.5 1,680 7.9 12 35 0.80 54 AD00 90-4/75 1.5 1,680 7.9 13 35 0.80 75 AD00 90-2/85 3.0 3,360 17 22 83 0.83 108 AD00 90-2/85 3.0 3,360 17 24 83 0.83 150 AD00 90-2/85 3.0 3,360 17 31 83 0.83 216 200 AD00 90-2/85 3.0 3,360 17 31 83 0.83 SA 14.5 4.8 VD00 90-8/60 0.37 840 5.5 6.6 13 0.45 6.7 500 VD00 90-8/60 0.37 840 5.5 6.6 13 0.45 9.6 VD00 90-4/50 0.75 1,680 5.0 7.9 20 0.70 13 VD00 90-4/50 0.75 1,680 5.0 8.6 20 0.70 19 VD00 90-2/50 1.5 3,360 9.4 13 39 0.72 26 VD00 90-2/50 1.5 3,360 9.4 15 39 0.72 38 AD00 90-4/130 3.0 1,680 15 22 83 0.80 54 AD00 90-4/130 3.0 1,680 15 24 83 0.80 75 AD00 90-2/130 4.0 3,360 22 35 127 0.78 108 AD00 90-2/130 4.0 3,360 22 37 127 0.78 150 AD00 90-2/130 4.0 3,360 22 48 127 0.78 216 400 AD00 90-2/130 4.0 3,360 22 48 127 0.78 SA 16.1 4.8 AD00 90-8/85 0.75 840 8.8 11 18 0.50 6.7 AD00 90-8/85 0.75 840 8.8 11 18 0.50 9.6 1,000 AD00 90-4/75 1.5 1,680 7.9 14 35 0.80 13 AD00 90-4/75 1.5 1,680 7.9 16 35 0.80 19 AD00 90-2/85 3.0 3,360 17 24 83 0.83 26 AD00 90-2/85 3.0 3,360 17 26 83 0.83 38 AD00 112-4/110 5.5 1,680 29 42 132 0.77 54 AD00 112-4/110 5.5 1,680 29 48 132 0.77 75 AD00 112-2/140 7.5 3,360 39 66 263 0.78 108 AD00 112-2/140 7.5 3,360 39 72 263 0.78 150 800 AD00 112-2/140 7.5 3,360 39 77 263 0.78 216 AD00 112-2/140 7.5 3,360 39 99 263 0.78 1) Current at running torque according to “Technical data SA 07.1 – SA 48.1” 2) Current at max. torque. We recommend to select switching devices according to these values. Y005.354/002/en Electrical data Multi-turn actuators for open-close duty with 3-phase AC motors Short-time duty S2 - 15 min, 208 V/60 Hz SA 07.1 – SA 25.1 Issue 1.11 We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. 1/2

Transcript of Multi-turn actuators SA 07.1 - AUMA for valve automation VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.60...

Page 1: Multi-turn actuators SA 07.1 - AUMA for valve automation VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.60 ... (AUMA NORM), these have to be connected to the external control circuit (see terminal

Multi-turn actuator MotorType Speed

rpm

Torque

max. NmType Power

PN (kW)Speed

rpm

Nominalcurrent1)

IN (A)

Current2)

approx. Imax.(A)

StartingcurrentIA (A)

cos ϕ

SA 07.1

4.8 VD00 63-4/30A 0.025 1,680 0.9 0.9 2.2 0.506.7

30

VD00 63-4/30A 0.025 1,680 0.9 0.9 2.2 0.509.6 VD00 63-4/30 0.045 1,680 0.9 1.1 2.2 0.50

13 VD00 63-4/30 0.045 1,680 0.9 1.1 2.2 0.5019 VD00 63-2/30 0.09 3,360 1.3 1.3 4.2 0.6026 VD00 63-2/30 0.09 3,360 1.3 1.3 4.2 0.6038 AD00 63-4/50 0.18 1,680 2.0 2.4 5.3 0.5054 AD00 63-4/50 0.18 1,680 2.0 2.6 5.3 0.5075 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73

108 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73150 AD00 63-2/60 0.37 3,360 2.2 2.6 9.6 0.73216 25 AD00 63-2/60 0.37 3,360 2.2 2.9 9.6 0.73

SA 07.5

4.8 VD00 63-4/30B 0.046 1,680 0.9 1.8 2.2 0.506.7

60

VD00 63-4/30B 0.046 1,680 0.9 1.8 2.2 0.509.6 VD00 63-4/45 0.09 1,680 1.3 1.3 3.5 0.49

13 VD00 63-4/45 0.09 1,680 1.3 1.3 3.5 0.4919 VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.6026 VD00 63-2/45 0.18 3,360 1.5 2.2 6.6 0.6038 AD00 63-4/80 0.37 1,680 3.7 4.6 10 0.5854 AD00 63-4/80 0.37 1,680 3.7 6.1 10 0.5875 AD00 63-2/80 0.75 3,360 3.7 5.0 20 0.80

108 AD00 63-2/80 0.75 3,360 3.7 5.7 20 0.80150 AD00 63-2/80 0.75 3,360 3.7 5.7 20 0.80216 50 AD00 63-2/80 0.75 3,360 3.7 7.0 20 0.80

SA 10.1

4.8 VD00 71-4/35A 0.09 1,680 1.1 1.3 4.4 0.606.7

120

VD00 71-4/33A 0.09 1,680 1.1 1.3 4.4 0.609.6 VD00 71-4/35 0.18 1,680 2.2 2.4 6.6 0.49

13 VD00 71-4/35 0.18 1,680 2.2 2.6 6.6 0.4919 VD00 71-2/35 0.37 3,360 3.1 3.7 9.9 0.6726 VD00 71-2/35 0.37 3,360 3.1 4.2 9.9 0.6738 AD00 71-4/80 0.75 1,680 5.5 6.6 19 0.6454 AD00 71-4/80 0.75 1,680 5.5 7.0 19 0.6475 AD00 71-2/80 1.5 3,360 8.8 11 35 0.70

108 AD00 71-2/80 1.5 3,360 8.8 13 35 0.70150 AD00 71-2/80 1.5 3,360 8.8 12 35 0.70216 100 AD00 71-2/80 1.5 3,360 8.8 15 35 0.70

SA 14.1

4.8 VD00 90-8/40 0.18 840 3.9 4.4 9.9 0.4556.7

250

VD00 90-8/40 0.18 840 3.9 4.4 9.9 0.459.6 VD00 90-4/40 0.37 1,680 2.4 3.7 11 0.74

13 VD00 90-4/40 0.37 1,680 2.4 3.9 11 0.7419 VD00 90-2/40 0.75 3,360 4.2 7.7 20 0.8126 VD00 90-2/40 0.75 3,360 4.2 8.3 20 0.8138 AD00 90-4/75 1.5 1,680 7.9 12 35 0.8054 AD00 90-4/75 1.5 1,680 7.9 13 35 0.8075 AD00 90-2/85 3.0 3,360 17 22 83 0.83

108 AD00 90-2/85 3.0 3,360 17 24 83 0.83150 AD00 90-2/85 3.0 3,360 17 31 83 0.83216 200 AD00 90-2/85 3.0 3,360 17 31 83 0.83

SA 14.5

4.8 VD00 90-8/60 0.37 840 5.5 6.6 13 0.456.7

500

VD00 90-8/60 0.37 840 5.5 6.6 13 0.459.6 VD00 90-4/50 0.75 1,680 5.0 7.9 20 0.70

13 VD00 90-4/50 0.75 1,680 5.0 8.6 20 0.7019 VD00 90-2/50 1.5 3,360 9.4 13 39 0.7226 VD00 90-2/50 1.5 3,360 9.4 15 39 0.7238 AD00 90-4/130 3.0 1,680 15 22 83 0.8054 AD00 90-4/130 3.0 1,680 15 24 83 0.8075 AD00 90-2/130 4.0 3,360 22 35 127 0.78

108 AD00 90-2/130 4.0 3,360 22 37 127 0.78150 AD00 90-2/130 4.0 3,360 22 48 127 0.78216 400 AD00 90-2/130 4.0 3,360 22 48 127 0.78

SA 16.1

4.8 AD00 90-8/85 0.75 840 8.8 11 18 0.506.7 AD00 90-8/85 0.75 840 8.8 11 18 0.509.6

1,000

AD00 90-4/75 1.5 1,680 7.9 14 35 0.8013 AD00 90-4/75 1.5 1,680 7.9 16 35 0.8019 AD00 90-2/85 3.0 3,360 17 24 83 0.8326 AD00 90-2/85 3.0 3,360 17 26 83 0.8338 AD00 112-4/110 5.5 1,680 29 42 132 0.7754 AD00 112-4/110 5.5 1,680 29 48 132 0.7775 AD00 112-2/140 7.5 3,360 39 66 263 0.78

108 AD00 112-2/140 7.5 3,360 39 72 263 0.78150 800

AD00 112-2/140 7.5 3,360 39 77 263 0.78216 AD00 112-2/140 7.5 3,360 39 99 263 0.78

1) Current at running torque according to “Technical data SA 07.1 – SA 48.1”2) Current at max. torque. We recommend to select switching devices according to these values.

Y005.354/002/en

Electrical data Multi-turn actuators for open-close dutywith 3-phase AC motorsShort-time duty S2 - 15 min, 208 V/60 Hz

SA 07.1 – SA 25.1

Issue 1.11

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

1/2

Page 2: Multi-turn actuators SA 07.1 - AUMA for valve automation VD00 63-2/45 0.18 3,360 1.5 2.0 6.6 0.60 ... (AUMA NORM), these have to be connected to the external control circuit (see terminal

Multi-turn actuator MotorType Speed

rpm

Torque

max. NmType Power

PN (kW)Speed

rpm

Nominalcurrent1)

IN (A)

Current2)

approx. Imax.(A)

StartingcurrentIA (A)

cos ϕ

SA 25.1

4.8

2,000

AD00 90-8/130 1.1 840 15 20 37 0.486.7 AD00 90-8/130 1.1 840 15 22 37 0.489.6 AD00 90-4/130 3.0 1,680 15 24 83 0.80

13 AD00 90-4/130 3.0 1,680 15 26 83 0.8019 AD00 90-2/130 4.0 3,360 22 35 127 0.7826 AD00 90-2/130 4.0 3,360 22 44 127 0.7838 AD00 132-4/140 7.5 1,680 48 88 263 0.6554 AD00 132-4/140 7.5 1,680 48 105 263 0.6575 AD00 132-2/180 15 3,360 66 132 417 0.90

108 AD00 132-2/180 15 3,360 66 153 417 0.90

Motor data is approximate. Due to usual manufacturing tolerances, there may be deviations from the values given.The permissible fluctuation of the nominal voltage is ± 10 %. If the voltage drops below, there is a reduction of the nominal outputtorque.To protect against overheating, thermoswitches or PTC thermistors are embedded in the motor windings. For actuatorswithout integral controls (AUMA NORM), these have to be connected to the external control circuit (see terminal plan).If thermoswitches or PTC thermistors are not connected, this voids our warranty for the motor.

Rating of the thermoswitches:

For further details refer to “Technical data Multi-turn actuators for open-close duty with 3-phase AC motors SA 07.1 – SA 48.1”.

1) Current at running torque according to “Technical data SA 07.1 – SA 48.1”2) Current at max. torque. We recommend to select switching devices according to these values.

Y005.354/002/en

Electrical data Multi-turn actuators for open-close dutywith 3-phase AC motorsShort-time duty S2 - 15 min, 208 V/60 Hz

SA 07.1 – SA 25.1

We reserve the right to alter data according to improvements made.We reserve the right to alter data according to improvements made.We reserve the right to alter data according to improvements made.

Issue 1.11

2/2

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Issue 1.11

AC DC

250 V, 50 – 60 Hz 60 V 1.0 A

cos ϕ = 1 2.5 A 42 V 1.2 A

cos ϕ = 0.6 1.6 A 24 V 1.5 A