High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at...

6
Pre-clinical in vivo imaging PRODUCT NOTE Key Features: • High resolution (4.5 μm voxel size) • High speed (8 second scans) • Low dose imaging for longitudinal studies • Co-registration of molecular optical signals with anatomical microCT data • Two physical magnifications for a range of resolutions and doses • Two-phase respiratory and cardiac gating • Mouse/rat/rabbit imaging capabilities The Quantum GX is the most advanced microCT imaging system for preclinical research, offering industry leading resolution combined with high speed imaging capability at an X-ray dose low enough to enable true longitudinal imaging of animals. The Quantum GX is the only multispecies microCT system with the capability to image entire mice, rats and rabbits. This high resolution, high speed integrated platform enables researchers to gain a better understanding of disease in a broad range of applications in cardiovascular, respiratory, bone, lung and brain imaging research. Gain more insight into the molecular, functional and anatomical readouts of the experimental model by coregistering of 3D optical data from PerkinElmer's IVIS ® and FMT ® platforms with the Quantum GX microCT system for a better understanding of disease and its progression. High Performance High Speed High Resolution microCT Quantum GX

Transcript of High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at...

Page 1: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

Pre-clinical in vivo imaging

P R O D U C T N O T E

Key Features:

•Highresolution(4.5μmvoxelsize)

•Highspeed(8secondscans)

•Lowdoseimagingforlongitudinalstudies

•Co-registrationofmolecularopticalsignals withanatomicalmicroCTdata

•Twophysicalmagnificationsforarangeof resolutions and doses

•Two-phaserespiratoryandcardiacgating

•Mouse/rat/rabbitimagingcapabilities

TheQuantumGXisthemostadvancedmicroCTimaging systemforpreclinicalresearch,offeringindustryleadingresolutioncombinedwithhigh

speedimagingcapabilityatanX-raydoselowenoughtoenabletruelongitudinalimagingofanimals.TheQuantumGXistheonlymultispeciesmicroCTsystemwiththecapabilitytoimageentiremice,ratsandrabbits.

Thishighresolution,highspeedintegratedplatformenablesresearchers togainabetterunderstandingofdiseaseinabroadrangeofapplicationsincardiovascular,respiratory,bone,lungandbrainimagingresearch.

Gainmoreinsightintothemolecular,functionalandanatomicalreadouts oftheexperimentalmodelbycoregisteringof3DopticaldatafromPerkinElmer'sIVIS®andFMT®platformswiththeQuantumGXmicroCTsystem forabetterunderstandingofdiseaseanditsprogression.

High PerformanceHigh Speed High Resolution microCT

Quantum GX

Page 2: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

2

High Resolution Imaging at a 4.5 μm Voxel Size

TheQuantumGXoffersthehighestresolutionamongall themicroCTscannersforin vivoimaging.Thewidefieldofview(FOV)scanningat36mmand72mmallowsforhighresolutionimagingofmice,ratsandrabbits.Thesystemhasthreemodes:highresolution,highspeedandstandardmodes.Asanexample,inthehighresolutionmode,a4.5μmvoxelsizeresolutioncanbeattainedata36x36mmFOV,whilea 9μmvoxelsizeresolutioncanbeattainedat72x72mmFOV.

AnadvancedboneanalysissoftwarepackageisavailableasacompaniontotheQuantumGXthatofferssuperiorvisualizationtoolsforbonesegmentation,BMDmeasurementsandbonemorphologyassessment(trabecularandcorticalparameters)in auser-friendlyworkflow. Figure 1. Top: High resolution microCT image of mouse femur (4.5 micron voxel, 8k

x 8k pixels) Bottom: Heart and vasculature imaging with contrast agent, Cortical bone and bone segmentation images.

Figure 3. Top: High Speed Imaging: 8 second scan of mouse lung region and whole mouse scan in 24 seconds. Bottom: Low dose: Longitudinal imaging tibial osteolytic lesions casued by human breast cancer cell line MDA-MB-231.

High Speed/Low Dose Imaging

TheQuantumGXisthefastestmicroCTsystemwithindustryleadingscantimesof8secondsinthehighspeedmode. Withareconstructiontimeof15seconds,a3Dimagecan beacquiredandreconstructedwiththeGXin23seconds.

WiththeQuantumGX,followandcharacterizediseaseprogressionthroughouttheentirestudyusingmicroCTateveryimagingpoint.Usingthe8secondscantimethatisdesigned tosimultaneouslygivelowdoseandgoodimagequality,researcherscanbeconfidentthattheirbiologicalmodelwillremainrelevantthroughoutthespanoftheexperiment.Fastimagingandsmoothworkflowsalsoenablethethroughputrequiredtoscancohortsofanimalsquicklyanddrawsoundconclusionsfromexperimentaldata.

Superior Workflow for High Resolution Scans

TheQuantumGXimagingsystemfeaturesanadvancedworkflowforcreatinghighresolutionimagesfromtheoriginalwholeimagescan.Awholebodyscanisfirsttakenandthenregionsofinterests(ROIs)aredefinedtoreconstructahighresolutionimage.Sincethereisnoneedtorescantheanimal,thethroughputishigherandradiationexposureissignificantlyreduced.ThelargerfieldofviewscanoffersflexibilitytoselectanROIfordetailatalaterstage.SubvolumereconstructionswithvariousresolutionsettingscanbeperformedatanytimeusinganFOVdefinedbytheuser.

Figure 2. A 4.5 micron post reconstruction (bottom image) from initial image (top) which was taken in high resolution mode (FOV 36, 72 micron pixel size).

Day 7 Day 14 Day 21 Day 24

Page 3: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

3

Figure 5. Two-phase gating technique on the Quantum GX offers reconstructions with less motion artifacts.

FPO

Inspiration

Expiration

Two-Phase Cardiac and Respiratory Gating

ForaccuratemicroCTreconstructionincardiacandrespiratorygatedapplications,itisextremelyimportanttominimizethemotionfromthediaphragmandheart.TheQuantumGX’sadvancedandsimpleintrinsicretrospectivetwo-phasegatingtechniquesareideallysuitedforcardiacandlungfunctionmeasurements.Bysimplydrawingaregionofinterestoverthediaphragmand/orapexoftheheart,theoptionalsoftwarethenreprocessesthedata,usingonlytheviewsfromtheselectedsliceintherespiratoryorcardiaccycle,reducingmotionartifactsin the reconstruction.

Figure 4. Optical co-registration of luciferase labeled MDA-MB-231 metastases with microCT.

Optical Co-registration for Multimodality Imaging

PerkinElmerhasrevolutionizedpreclinical3DopticalimagingwiththeIVISandFMTplatforms.TheQuantumGXmakesmicroCTimagingaseasyasopticalimagingontheIVISandallowsresearcherstoco-registerfunctionalopticalsignalswithanatomicalmicroCTdata.Throughputanduserworkflowhavebeensimplifiedtoseamlesslyco-registeranatomicalandfunctionaldataateverystepofalongitudinalstudy.

Multispecies Imaging

TheQuantumGXfeaturesisatruemultispeciesmicroCTsystemwithaboresizelargeenoughtofitentiremice,ratsandevenrabbits.TheboresizeintheQuantumGXis163mm andwithavailablemouse,ratandrabbitbeds,animalsupto5kgcanbeeasilyimaged.Anentiremousecanbeimagedinonescan.Aratcanbeimagedintwosetsofscansandaguineapigcanbeimagedinthreesetsofscans.

FPO

Mouse

Rat

Figure 6. The Quantum GX is an ideal multispecies imaging system. The system can image entire mice, rats, guinea pigs and even rabbits.

GuineaPig

Page 4: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

4

Quantum GX High Performance microCT for Preclinical Applications

InjuredNormal

RatwithMIA-inducedosteoarthritisintheknee.Theimageontheleftshowsadiseasedjointcomparedtothenormaljoint on the right

OsteoarthritisNormal

NormalOsteoarthritis

Osteoarthritis Lung Injury

Contrast Agent Enhanced Imaging

Heartandpulmonaryvasculature Livervasculatureimaging 4T1tumorvasculature Lungsegmentation

Additional Applications• Bone research • Bonemorphology(trabecularandcorticalbone)

assessment,BMDmeasurements

• Cardiovascular disease • Myocardialviability,calciumscoring,ventricular

functionandmetabolism,infarcthealing

• Pulmonary disease • Lungairwaystructureandwholelunginacute

injurymodels

•Volume,densityandFRC(functionalresidual capacity)measurements

• Metabolic disease • Differentiationofvisceralandsubcutaneousfat

Page 5: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

5

Optional Accessories

Other Accessories

•AdvancedmicroCTanalysissoftware

•Cardiac/respiratorygatingsoftware

•3Dmultimodalitymodule

•Adapterarms(Spectrum,FMT)

•Rabbitbed

MouseImagingShuttle

IVISSyringeInjectionSystemXGI-8AnesthesiaSystem

Quantum GX Technical Specifications

CTimage

Fieldofview 72mm(max)

Resolution(pixelsize) 4.5μm(min)

Numberofpixels512×512×512- 8000×8000

X-raytube

Maximumtubevoltage 90kV

Maximumtubecurrent 200 μA

Maximumoutput 8 W

DetectorType Flat panel detector

FrameRate 60fps(max)

CTgantryBoreSize 163mm(max)

Scanablerange 240mm(max)

Scantimes

HighSpeed: 8sec Standard: 18sec,2min HighResolution: 4min, 14min,57min

ImagereconstructionMin.15sec@512×512pixels×512view

SoftwareAcquisition and visualizationpackage

Dimensions(HxWxD) 1450x980x930mm

Weight 450 kg

XWS-260Workbench

Page 6: High Performance High Speed High Resolution microCT · 2016. 2. 15. · High Resolution Imaging at a 4.5 μm Voxel Size The Quantum GX offers the highest resolution among all the

For more information, please visit www.perkinelmer.com/invivo

For research use only. Not for use in diagnostic procedures.

For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs

Copyright ©2015, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 012164_01 PKI

PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602www.perkinelmer.com