Pre-clinical in vivo imaging
P R O D U C T N O T E
Key Features:
•Highresolution(4.5μmvoxelsize)
•Highspeed(8secondscans)
•Lowdoseimagingforlongitudinalstudies
•Co-registrationofmolecularopticalsignals withanatomicalmicroCTdata
•Twophysicalmagnificationsforarangeof resolutions and doses
•Two-phaserespiratoryandcardiacgating
•Mouse/rat/rabbitimagingcapabilities
TheQuantumGXisthemostadvancedmicroCTimaging systemforpreclinicalresearch,offeringindustryleadingresolutioncombinedwithhigh
speedimagingcapabilityatanX-raydoselowenoughtoenabletruelongitudinalimagingofanimals.TheQuantumGXistheonlymultispeciesmicroCTsystemwiththecapabilitytoimageentiremice,ratsandrabbits.
Thishighresolution,highspeedintegratedplatformenablesresearchers togainabetterunderstandingofdiseaseinabroadrangeofapplicationsincardiovascular,respiratory,bone,lungandbrainimagingresearch.
Gainmoreinsightintothemolecular,functionalandanatomicalreadouts oftheexperimentalmodelbycoregisteringof3DopticaldatafromPerkinElmer'sIVIS®andFMT®platformswiththeQuantumGXmicroCTsystem forabetterunderstandingofdiseaseanditsprogression.
High PerformanceHigh Speed High Resolution microCT
Quantum GX

2
High Resolution Imaging at a 4.5 μm Voxel Size
TheQuantumGXoffersthehighestresolutionamongall themicroCTscannersforin vivoimaging.Thewidefieldofview(FOV)scanningat36mmand72mmallowsforhighresolutionimagingofmice,ratsandrabbits.Thesystemhasthreemodes:highresolution,highspeedandstandardmodes.Asanexample,inthehighresolutionmode,a4.5μmvoxelsizeresolutioncanbeattainedata36x36mmFOV,whilea 9μmvoxelsizeresolutioncanbeattainedat72x72mmFOV.
AnadvancedboneanalysissoftwarepackageisavailableasacompaniontotheQuantumGXthatofferssuperiorvisualizationtoolsforbonesegmentation,BMDmeasurementsandbonemorphologyassessment(trabecularandcorticalparameters)in auser-friendlyworkflow. Figure 1. Top: High resolution microCT image of mouse femur (4.5 micron voxel, 8k
x 8k pixels) Bottom: Heart and vasculature imaging with contrast agent, Cortical bone and bone segmentation images.
Figure 3. Top: High Speed Imaging: 8 second scan of mouse lung region and whole mouse scan in 24 seconds. Bottom: Low dose: Longitudinal imaging tibial osteolytic lesions casued by human breast cancer cell line MDA-MB-231.
High Speed/Low Dose Imaging
TheQuantumGXisthefastestmicroCTsystemwithindustryleadingscantimesof8secondsinthehighspeedmode. Withareconstructiontimeof15seconds,a3Dimagecan beacquiredandreconstructedwiththeGXin23seconds.
WiththeQuantumGX,followandcharacterizediseaseprogressionthroughouttheentirestudyusingmicroCTateveryimagingpoint.Usingthe8secondscantimethatisdesigned tosimultaneouslygivelowdoseandgoodimagequality,researcherscanbeconfidentthattheirbiologicalmodelwillremainrelevantthroughoutthespanoftheexperiment.Fastimagingandsmoothworkflowsalsoenablethethroughputrequiredtoscancohortsofanimalsquicklyanddrawsoundconclusionsfromexperimentaldata.
Superior Workflow for High Resolution Scans
TheQuantumGXimagingsystemfeaturesanadvancedworkflowforcreatinghighresolutionimagesfromtheoriginalwholeimagescan.Awholebodyscanisfirsttakenandthenregionsofinterests(ROIs)aredefinedtoreconstructahighresolutionimage.Sincethereisnoneedtorescantheanimal,thethroughputishigherandradiationexposureissignificantlyreduced.ThelargerfieldofviewscanoffersflexibilitytoselectanROIfordetailatalaterstage.SubvolumereconstructionswithvariousresolutionsettingscanbeperformedatanytimeusinganFOVdefinedbytheuser.
Figure 2. A 4.5 micron post reconstruction (bottom image) from initial image (top) which was taken in high resolution mode (FOV 36, 72 micron pixel size).
Day 7 Day 14 Day 21 Day 24

3
Figure 5. Two-phase gating technique on the Quantum GX offers reconstructions with less motion artifacts.
FPO
Inspiration
Expiration
Two-Phase Cardiac and Respiratory Gating
ForaccuratemicroCTreconstructionincardiacandrespiratorygatedapplications,itisextremelyimportanttominimizethemotionfromthediaphragmandheart.TheQuantumGX’sadvancedandsimpleintrinsicretrospectivetwo-phasegatingtechniquesareideallysuitedforcardiacandlungfunctionmeasurements.Bysimplydrawingaregionofinterestoverthediaphragmand/orapexoftheheart,theoptionalsoftwarethenreprocessesthedata,usingonlytheviewsfromtheselectedsliceintherespiratoryorcardiaccycle,reducingmotionartifactsin the reconstruction.
Figure 4. Optical co-registration of luciferase labeled MDA-MB-231 metastases with microCT.
Optical Co-registration for Multimodality Imaging
PerkinElmerhasrevolutionizedpreclinical3DopticalimagingwiththeIVISandFMTplatforms.TheQuantumGXmakesmicroCTimagingaseasyasopticalimagingontheIVISandallowsresearcherstoco-registerfunctionalopticalsignalswithanatomicalmicroCTdata.Throughputanduserworkflowhavebeensimplifiedtoseamlesslyco-registeranatomicalandfunctionaldataateverystepofalongitudinalstudy.
Multispecies Imaging
TheQuantumGXfeaturesisatruemultispeciesmicroCTsystemwithaboresizelargeenoughtofitentiremice,ratsandevenrabbits.TheboresizeintheQuantumGXis163mm andwithavailablemouse,ratandrabbitbeds,animalsupto5kgcanbeeasilyimaged.Anentiremousecanbeimagedinonescan.Aratcanbeimagedintwosetsofscansandaguineapigcanbeimagedinthreesetsofscans.
FPO
Mouse
Rat
Figure 6. The Quantum GX is an ideal multispecies imaging system. The system can image entire mice, rats, guinea pigs and even rabbits.
GuineaPig

4
Quantum GX High Performance microCT for Preclinical Applications
InjuredNormal
RatwithMIA-inducedosteoarthritisintheknee.Theimageontheleftshowsadiseasedjointcomparedtothenormaljoint on the right
OsteoarthritisNormal
NormalOsteoarthritis
Osteoarthritis Lung Injury
Contrast Agent Enhanced Imaging
Heartandpulmonaryvasculature Livervasculatureimaging 4T1tumorvasculature Lungsegmentation
Additional Applications• Bone research • Bonemorphology(trabecularandcorticalbone)
assessment,BMDmeasurements
• Cardiovascular disease • Myocardialviability,calciumscoring,ventricular
functionandmetabolism,infarcthealing
• Pulmonary disease • Lungairwaystructureandwholelunginacute
injurymodels
•Volume,densityandFRC(functionalresidual capacity)measurements
• Metabolic disease • Differentiationofvisceralandsubcutaneousfat

5
Optional Accessories
Other Accessories
•AdvancedmicroCTanalysissoftware
•Cardiac/respiratorygatingsoftware
•3Dmultimodalitymodule
•Adapterarms(Spectrum,FMT)
•Rabbitbed
MouseImagingShuttle
IVISSyringeInjectionSystemXGI-8AnesthesiaSystem
Quantum GX Technical Specifications
CTimage
Fieldofview 72mm(max)
Resolution(pixelsize) 4.5μm(min)
Numberofpixels512×512×512- 8000×8000
X-raytube
Maximumtubevoltage 90kV
Maximumtubecurrent 200 μA
Maximumoutput 8 W
DetectorType Flat panel detector
FrameRate 60fps(max)
CTgantryBoreSize 163mm(max)
Scanablerange 240mm(max)
Scantimes
HighSpeed: 8sec Standard: 18sec,2min HighResolution: 4min, 14min,57min
ImagereconstructionMin.15sec@512×512pixels×512view
SoftwareAcquisition and visualizationpackage
Dimensions(HxWxD) 1450x980x930mm
Weight 450 kg
XWS-260Workbench

For more information, please visit www.perkinelmer.com/invivo
For research use only. Not for use in diagnostic procedures.
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs
Copyright ©2015, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 012164_01 PKI
PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602www.perkinelmer.com