FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm...

5
FAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a. Medium: Air, oxygen, neutral gases (10 % ... 95 % humidity, non condensing), 40 μm filtered Operation: Direct acting 2-way and 3-way valves, normally closed and normally opened Operating pressure: 0 ... 10 bar (0 ... 145 psi) Details on page 2 Flow: 5 … 32 l/min at 2 bar (29 psi) at +20 °C (+68°F) Mounting: Manifold Orifice: 0,6 .... 2 mm Response time: 10 ... 15 ms Response time measured according to ISO 12238 Life expectancy: ≥100 Mio. cycles for 1 W valves Weight: 10,5 g (0.023 lbs) Ambient/media temperature: -10 ... +50 °C (+14 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2 °C (+35°F). Electrical details Technical features Following options on request Materials: Body: PPS Seat seals: FPM, NBR, EPDM Internal parts: Stainless steel, PAA Pulse width modulation (PWM) control A PWM can be used to control the valve and should be set as follows: Definition Value to be applied Hit voltage Voltage used for he valve to commute Valve nominal voltage Holding voltage Voltage applied to he valve after commutation Set duty cycle to guarantee specified holding voltage. 50% of nominal voltage can be used if no value specified. Hit time Maximum time required to ensure full valve commutation 40 ms at T > 20 °C *1) PWM frequency 20 ... 30 kHz *1) Please contact us for application outside of those conditions. > 2/2, 3/2; Manifold mounting > Compact Design > Long life – 100 million cycles > Low power consumption Voltage: 24 V d.c. Rating: 100 % E.D. Voltage tolerance ± 10% Power consumption: 1[W] (3/0,3 W)* Electrical insulation 1000 V a.c. Protection class IP 51 Insulation class F (155°C) * with optional PWM control Operating pressure (vacuum) Medium temperature Ambient temperature Response time Power consumption Materials Coils Protection class Degreased for oxygen use Manual override Embedded electronics options Integrated pulse width modulation (PWM) Enhanced opening time repeatability Larger input voltage tolerances Improved boosting by plunger movement detection Improved boosting by plunger movement detection wi h power adaptation Faster valve closing Current control for improved performances over temperature range Reverse polarity protection Led signalization

Transcript of FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm...

Page 1: FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued

FAS 10 mm PICOSOL Direct acting solenoid valve

4/15en 5.2.030.01

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a.

Medium:Air, oxygen, neutral gases(10 % ... 95 % humidity, noncondensing), 40 μm filteredOperation:Direct acting 2-way and 3-wayvalves, normally closed and normally openedOperating pressure:0 ... 10 bar (0 ... 145 psi) Details on page 2

Flow:5 … 32 l/min at 2 bar (29 psi)at +20 °C (+68°F)Mounting:ManifoldOrifice:0,6 .... 2 mmResponse time:10 ... 15 msResponse time measuredaccording to ISO 12238

Life expectancy:≥100 Mio. cycles for 1 W valvesWeight:10,5 g (0.023 lbs)Ambient/media temperature:-10 ... +50 °C (+14 ... +122°F)Air supply must be dry enoughto avoid ice formation attemperatures below +2 °C (+35°F).

Electrical details

Technical features

Following options on request

Materials:Body: PPSSeat seals: FPM, NBR, EPDMInternal parts: Stainless steel, PAA

Pulse width modulation (PWM) controlA PWM can be used to control the valve and should be set as follows:

Definition Value to be applied

Hit voltage Voltage used for he valve to commute Valve nominal voltage

Holding voltage Voltage applied to he valve after commutation Set duty cycle to guarantee specified holding voltage. 50% of nominal voltage can be used if no value specified.

Hit time Maximum time required to ensure full valve commutation 40 ms at T > 20 °C *1)

PWM frequency 20 ... 30 kHz

*1) Please contact us for application outside of those conditions.

> 2/2, 3/2; Manifold mounting

> Compact Design

> Long life – 100 million cycles

> Low power consumption

Voltage: 24 V d.c.

Rating: 100 % E.D.

Voltage tolerance ± 10%

Power consumption: 1[W] (3/0,3 W)*

Electrical insulation 1000 V a.c.

Protection class IP 51

Insulation class F (155°C)

* with optional PWM control

Operating pressure (vacuum)

Medium temperature

Ambient temperature

Response time

Power consumption

Materials

Coils

Protection class

Degreased for oxygen use

Manual override

Embedded electronics optionsIntegrated pulse width modulation (PWM)

Enhanced opening time repeatability

Larger input voltage tolerances

Improved boosting by plunger movement detection

Improved boosting by plunger movement detection wi h power adaptationFaster valve closing

Current control for improved performances over temperature rangeReverse polarity protection

Led signalization

Page 2: FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued

FAS 10 mm PICOSOL Direct acting solenoid valve

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a.en 5.2.030.02

4/15

Technical data - standard models

Accessories Electrical connectionMounting plate with barbed fittings for 3 mm ØID tubing (up to 2 bar)

Page 4

Mounting manifold with M3 threads — 1 position

Page 4

Mounting manifold with M5 threads — 1 ... 8 positions

Page 5

S111.1772 S110.1277 Available on request

Electrical connector Molex 50-57-9402 with 300 mm flying leads

Page 5

S110.1032

Symbol Operation Orifice

(mm)

Operating pres-sure(bar) (psi)

kv*1) (l/min)

Power consumption (W) *2)

Voltage

(V d.c.)

Manual override *3)

Seal mate-rial

Drawing

no.

Model

3

2

1012 2/2 NO (3/2 mounting pattern)

0,6 0 ... 10 0 ... 145 0,12 1 24 With FPM 2 11-221PI060H1+1111+AYV

1,1 0 ... 4 0 ... 58 0,3 1 24 With FPM 2 11-221PI011H1+1111+AYR

2

1

2

1

0

10

2

12 2/2 NC (3/2 mounting pattern)

0,6 0 ... 8 0 ... 116 0,12 1 24 With FPM 2 11-211PI060H1+1111+AYV

0,8 2 ... 8 29 ... 116 0,19 1 24 With FPM 2 11-211PI01-H1+1111+AYV

1,1 0,5 ... 2,1 7.2 ... 30 0,3 1 24 With FPM 2 11-211PI011H1+1111+AYV

2

1

1012

2/2 NC

0,8 0 ... 8 0 ... 116 0,2 1 24 Without FPM 1 11-211P601-H1+1311+AYV

1,2 0 ... 4 0 ... 58 0,39 1 24 Without FPM 1 11-211P602-H1+1311+AYR

1,6 0 ... 8 0 ... 116 0,54 4/0,4 24 Without FPM 1 11-211P603-H1+6311+AXA

2

1012

3

2

1 3

3/2 NC

0,6 0 ... 8 0 ... 116 0,12 1 24 With FPM 2 11-311PI060H1+1111+AYV

0,8 2 ... 8 29 ... 116 0,19 1 24 With FPM 2 11-311PI01-H1+1111+AYV

1,1 2 ... 8 29 ... 116 0,37 3/0,3 24 With FPM 2 11-311PI011H1+6111+AZR

1,3 2 ... 6,5 29 ... 94 0,44 3/0,3 24 With FPM 2 11-311PI013H1+6111+AZR3

2 1012

12

1 3

3

2 10

1 3

3/2 NO

0,8 0 ... 6 0 ... 87 0,19 1 24 With FPM 2 11-321PI01-H1+1111+AYV2

3

112

1012

1 3

3

2

1 3

3/2 UNI

0,8 0 ... 2 0 ... 29 0,18 1 24 With FPM 2 11-331PI01-H1+1111+AYV

*1) Cv = 0,07 kv *2) Power consumption: “boosting power during ca. 50 ms”/ “holding power” *3) Push only

Page 3: FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a.

FAS 10 mm PICOSOL Direct acting solenoid valve

en 5.2.030.034/15

Dimensions

1

Dimensions shown in mmProjection/First angle

2

10

12,4

22,73,5

23

6,4

2,54

A

A

M2 1,

9

3,9

8,5

2,6

4,5

18,5

3 6,2

2

7

32

1

2

2

4

A

4

M1,

6

0,2

1,6

0,8

2,7

2,7

2,4

A

321

2

10

12,4

22,73,5

23

6,4

2,54

18,5

3

2

32

6,8

6,2

4

1 Manual override, push only 2 Sealing area 3 The recommended mounting screw tightening torque is 0,15 Nm. 4 Connector mates with Molex 50-57-9402

All solenoids are supplied with mounting screws and gasket.

Page 4: FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued

FAS 10 mm PICOSOL Direct acting solenoid valve

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a.en 5.2.030.04

4/15

Mounting manifold Model: on request

Mounting plate with barbed fittings for 3 mm ØID tubing (up to 2 bar) Model: S111.1772

Mounting manifold Model: S110.1277

Dimensions shown in mmProjection/First angle

5 Mounting thread M3 x 4,5 deep

1

5,5

5,5

20

12

M5

M5

M5

5

13

5

2 9

26,

5

10,5

A

A

5,5 19,57,5

3

2,6 7 10

,5

6,5

1

2

3

15

10

ø3,

6

ø1,

814,5

R3

1 Mounting thread M2 x 5 deep

10,5 ±0,1

3

6

10,5

15

5

8

M5 M5

M5

4,5

14

20

(N-1) x 10,5

10,5 ±0,16

(N-1) x 10,5

3

X

Y

5

Valve station X Y

2 16,5 22,5

3 27 33

4 37,5 43,5

5 48 54

6 58,5 64,5

7 69 75

8 79,5 85,5

Page 5: FAS 10 mm PICOSOL Direct acting solenoid valvecdn.norgren.com/pdf/en_5_2_030_PICOSOL.pdfFAS 10 mm PICOSOL Direct acting solenoid valve 4/15 en 5.2.030.01 Our policy is one of continued

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5017d) © 2015 Fluid Automation Systems s.a.

FAS 10 mm PICOSOL Direct acting solenoid valve

en 5.2.030.054/15

Dimensions shown in mmProjection/First angle

These products are intended for use in air, oxygen and neutral gas systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features«.

Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult IMI FAS.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.

Electrical connector Model: S110.1032

155

5,5

2,54

Warning