  • CLAMP-ON METER MEDIDOR DE TENAZA 500

    E N G L I S H User Manual

    MODEL 500CLAMP METER

    VA

    OFF

    HOLD

    COM

    H

    CAT II600V

    600V CAT II300V CAT III 400A

    AUTO VAH

    E S PA O L Manual de Instrucciones

  • Statement of Compliance

    Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.

    We guarantee that at the time of shipping your instrument has met its published specifications.

    An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.

    The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com.

    Serial #: ______________________________

    Catalog #: 2117.54

    Model #: 500

    Please fill in the appropriate date as indicated:

    Date Received: _________________________

    Date Calibration Due: ____________________

    Chauvin Arnoux, Inc.d.b.a AEMC Instrumentswww.aemc.com

  • Table of Contents

    1. INTRODUCTION ....................................................21.1 International Electrical Symbols .................................31.2 Receiving Your Shipment ...........................................31.3 Ordering Information ..................................................3

    2. PRODUCT FEATURES ...........................................42.1 Model 500 Control Features ......................................42.2 LCD Display ...............................................................52.3 Hold Button ................................................................5

    2.3.1 Data Hold ......................................................52.3.2 Disable Auto-off Function ..............................5

    3. SPECIFICATIONS ..................................................63.1 ElectricalSpecifications .............................................63.2 MechanicalSpecifications ..........................................73.3 SafetySpecifications ..................................................7

    4. OPERATION ..........................................................84.1 AC Current Measurement ..........................................84.2 AC Volt Measurement ................................................94.3 Resistance Measurement ........................................104.4 Continuity Test .......................................................... 11

    5. MAINTENANCE ...................................................125.1 Warning ....................................................................125.2 Cleaning ...................................................................125.3 Battery Replacement ...............................................13

    Repair, Calibration and Technical Assistance .................................14Warranty Information ..................................................................15

    ENGLISH ....................................................................................1ESPAOL .................................................................................. 17

  • 2 Clamp-on Meter Model 500

    CHAPTER 1

    INTRODUCTION

    Warning Read theusermanualbeforeoperatingand followall

    safety information. Onlyusethemeterasspecifiedinthisusermanual. Neverusethismeteronacircuitwithvoltagesgreater

    than 600Vrms @ 50/60Hz. Nevermeasure current while the test leads are con-

    nected to the input jacks. Donotoperatethemeterifthebodyortestsleadslook

    damaged. Checktherotaryrangeswitchandmakesureitisatthe

    correct position before each measurement. Donotperformresistanceandcontinuitytestonalive

    circuit. Useextremecautionwhenmeasuringlivesystemswith

    voltage greater than 60VDC or 30VAC. Useextremecarewhenworkingaroundbusbarsand

    bare conductors. Donotusethemeterinoverrange/overloadconditions

    (OL). Foraccuratereadings,changethebatterywhenthe

    symbol appears.

  • Clamp-on Meter Model 500 3

    1.1 International Electrical Symbols

    Thissymbolsignifiesthattheinstrumentisprotectedbydoubleorreinforcedinsulation.Useonlyspecifiedreplacementpartswhenservicingtheinstrument.

    This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed,bodilyinjury,installation/sampleandproductdamagemay result.

    Riskofelectricshock.Thevoltageat thepartsmarkedwiththis symbol may be dangerous.

    1.2 Receiving Your ShipmentUponreceivingyourshipment,makesurethatthecontentsareconsis-tentwiththepackinglist.Notifyyourdistributorofanymissingitems.If the equipment appears to be damaged, file a claim immediatelywith thecarrierandnotifyyourdistributoratonce,givingadetaileddescription of any damage. Save the damaged packing container to substantiate your claim.

    1.3 Ordering InformationClamp-on Meter Model 500 ........................................ Cat. #2117.54Includes meter, test leads, two 1.5V AAA batteries, user manual and soft carrying case.

  • 4 Clamp-on Meter Model 500

    CHAPTER 2

    PRODUCT FEATURES

    2.1 Model 500 Control Features

    MODEL 500CLAMP METER

    V

    A

    OFF

    HOLD

    COM

    H

    CAT II600V

    600V CAT II300V CAT III

    400A

    AUTO VAH

    IEC 1010

    600V CAT II

    POLLUTION DEGREE 2

    SIZE AAA 1.5V X 2

    WARNING

    TO AVOID ELECTRICAL

    SHOCK REMOVE ALL

    INPUTS BEFORE

    OPENING THE CASE

    PLEASE READ

    MANUAL FOR SAFETY

    1

    2

    4

    5

    6 8

    7

    3

    9

    1. Jawassembly(.98",25mm)

    2. Safety barrier anti-slip guard

    3. Leverforjawopening/closing

    4. Rotaryrangeselectorswitch

    5. LCD display

    6. COM (Black) input terminal jack

    7. Data hold button

    8. Positive (Red) input terminal jack

    9. Battery compartment cover

  • Clamp-on Meter Model 500 5

    2.2 LCD Display

    Lowbattery AC Input AUTO Auto Ranging Data Hold

    Continuitywithbeeper Ohm function selected V Voltage function selected A Current function selected

    2.3 Hold Button

    2.3.1 Data Hold

    Thelastreadingmaybeheldonthedisplaybypressingthe HOLD button. The symbolwillbedisplayed.

    Whenthedataisnolongerneeded,releasetheholdfunc-tion by pressing the HOLD button again.

    2.3.2 Disable Auto-off Function

    TurnrotaryswitchtotheOFFposition

    Pressandholddownthe button,thenpowerthemeterON by selecting a range.

    Upon the next power ON, the auto-off function will bereactivated.

    AUTO VAH

  • 6 Clamp-on Meter Model 500

    CHAPTER 3

    SPECIFICATIONS

    Reference Conditions: 23C 5C, 45 to 75% RH, 3V supply, conductor centered, earths magnetic field, no external magnetic or electrical field, sine wave 50/60Hz. Accuracy isexpressedas[%ofreading(R)counts(cts)].

    3.1 Electrical Specifications

    AC AmperesRange Resolution Accuracy Overload

    400A 0.1A50 to 60Hz: 2% of R 5cts

    60 to 500Hz: 2.8% of R 5cts600Arms

    AC Volts (Auto-ranging)

    Range Measurement Res. Accuracy Overload InputImpedance

    400V 0.5 to 399.9V 0.1V 50 to 60Hz:1.0% of R 5cts

    60 to 500Hz:1.5% of R 5cts

    600Vrms 1M600V 400 to 600V 1V

    Resistance - Ohms ()Range Measurement Res. Accuracy Test Voltage Overload

    400 0.3 to 399.9 0.1 1.9% of R 3cts 1.5VDC 600Vrms

    Continuity ( )Range Beeper Test Voltage Overload

    < 35 1.5VDC 600Vrms

  • Clamp-on Meter Model 500 7

    3.2 Mechanical Specifications

    Digital Display:3digitsLCDdisplay,4000-count(maxreading3999)

    Over Load: isdisplayedwheninputsignalexceedsrangeSample Rate: 2 samples/secPower Supply:Two1.5VAAA(LR03)alkalinebatteriesLow Battery Indication: The symbolisdisplayedwhenbatteryisbelowtherequiredvoltageBattery Life:300hoursapproxAuto Power Off:ThemeterwillpoweritselfOFFifthereisnopushbuttonorrotaryswitchoperationfor30minutesJaw Opening Size:1.1"(28mm)Dimensions: 7.60x1.97x1.1"(193x50x28mm)Weight:8.11oz(230g)withbatteriesAltitude: 2000 metersOperating Temperature:32 to 104F (0 to 40C),

  • 8 Clamp-on Meter Model 500

    CHAPTER 4

    OPERATION

    4.1 AC Current Measurement

    Turntherotaryrangeswitchtothe range. Pressthelevertoopenthejaws. Clampthejawsaroundtheconductortobemeasured. Immediately unclamp the meter from the conductor under test if

    overload" "isdisplayed. If reading is unstable and is hard to read, push the HOLD button

    and read the measurement.

    WARNING: Remove test leads before measuring current.

    V

    A

    OFF

    CAT II

    600V

    !

    CO

    M

    INS

    TR

    UM

    EN

    TS MODEL 500

    CLAMP M

    ETER

    HO

    LD

    H

    600V

    CAT II

    300V

    CAT III

    400A

    AU

    TO

    V

    A

    CAT II600V

    OFF

    !COM

    W

    INSTRUMENTS

    MODEL 500CLAMP METER

    HOLDH

    600V CAT II300V CAT III

    400A

    OK NO

    (twoconductorsfrom different phases)

  • Clamp-on Meter Model 500 9

    4.2 AC Volt Measurement

    Turntherotaryrangeswitchtothe range. Inserttheredtestleadtothered"+"inputjackandtheblacklead

    totheblack"COM"inputjack. Bringthetestprobetipsintocontactwiththetestpoints. Immediatelyremovethetestprobesfromthecircuitundertestif

    overload" "isdisplayed. Ifreadingisunstableandhardtoread,pusht