Emax2 electronic protection trip units

download Emax2 electronic protection trip units

of 52

  • date post

    07-Jul-2015
  • Category

    Technology

  • view

    107
  • download

    0

Embed Size (px)

description

διακοπτές ισχύος με ηλεκτρονικές ρυθμήσεις

Transcript of Emax2 electronic protection trip units

  • 1. ABB Emax 2

2. ABB | Emax 2 3 Ekip Dip 4 Ekip Touch 8 Ekip Hi-Touch 18 Ekip G Touch 22 Ekip G Hi-Touch 26 Ekip Power Controller 30 36 44 3. 2 3 1 4 5 6 1SDC200446F001 4 Emax 2 | ABB Ekip Dip Ekip Dip Emax 2, . L, S, I G LED . 1. LED (watchdog) 2. LED L, S, I G 3. (dip switches) Ekip Dip : Ekip Dip LI Ekip Dip LSI Ekip Dip LSIG 4. (dip switches) . 5. (test) 6. 4. I3 I2 t2 I t I t I t I I1 t1 50% 150% 100% 200% L S I I3 I4 t4 I2 t2 t I t I t I t I t I I I1 t1 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I t I I1 t1 I7 t7 t I 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I I7 t7 t I 50% 150% 100% 200% L S I steady state start-up I4 t4 t t I t I I7 t7 t I hot curve cold curve L S t I ABB | Emax 2 5 (L - ANSI 49): t = k/l2 . 25 (I1 ) 8 (t1 ) pre-alarm 90% . (S - ANSI 51 & 50TD): (t = k) (t = k/l2 ). 15 8 . (dip switches) OFF. (thermal memory): L S. , , . Ekip Connect , . (l - ANSI 50): . 15 (dip switches) OFF. (G - ANSI 51N & 50NTD): (t = k) (t = k/l2 ). (dip switches) OFF. : 50%, 100% 200% . L, S I. Ekip Dip reset (lockout device ANSI 86). 5. 6 Emax 2 | ABB Ekip Dip (1% 0,2 .. 1,2 x In ) IEC 61557-12. Ekip Multimeter Ekip Control Panel . , Ekip Dip . : , , 30 , 200 (.: / , pre-alarms, ..) : , , (firmware version) Ekip Multimeter ( Emax 2), Ekip Control Panel Ekip Connect smartphone, tablet PC ( Ekip T&P Ekip Bluetooth ). Emax 2 ( , , ) . , LED . , Ekip Dip ( ) / ( ANSI BF). , (OT - overtemprature), ( ). Ekip (thresholds) . 5 LED ( ) : K ( LED) pre-alarm Ekip Dip 6. ABB | Emax 2 7 (module) Ekip Bluetooth PC/laptop, smartphone tablet Ekip Connect. (, , ..) , alarm . (test) : Ekip TT Ekip T&P (report) iTest Ekip Dip , , . (module) Ekip Supply (24-48 VDC, 110-240 VDC 110-240 VAC) : G 100 A 0,2 In Ekip Multimeter Ekip Control Panel Ekip Dip / . Ekip 24-48 VDC 110-240 VAC/DC 21,5 - 53 VDC 105-265 VAC/DC ( modules) 10 W max. 10 W max. Inrush current 10 A 5 ms 10 A 5 ms 7. 1 2 3 4 5 7 6 1SDC200466F001 8 Emax 2 | ABB Ekip Touch Ekip Touch , . . . Ekip Touch : Ekip Touch LI Ekip Touch LSI Ekip Touch LSIG 1. 2. LED (watchdog) 3. LED pre-alarm 4. LED alarm 5. 6. (test) . 7. 8. 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I t I I1 t1 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I t I I1 t1 I7 t7 t I U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 t I t I t t I t I I7 t7 t I hot curve cold curve L S t I ABB | Emax 2 9 (L - ANSI 49): : 1. t = k/l2 2. IDMT (Inverse Definite Minimum Times) IEC 60255-3 . (SI - Standard Inverse), (VI - Very Inverse) (EI - Extremely Inverse) 3. t = k/l4 1 A E1.2 In =1000 A . pre-alarm 90% ( L=off). (S - ANSI 51 & 50TD): (t = k) (t = k/l2 ) (thermal memory): L S. , . Ekip Connect , . (l - ANSI 50): ( ). (MCR): I, () . I. . (G - ANSI 51N & 50TD): (t = k) (t = k/l2 ). pre-alarm 90% . Ekip Touch . , reset (lockout device ANSI 86). 9. 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I t I I1 t1 I7 t7 t I 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 I2 t2 t I t I t I t I t I t I I1 t1 I7 t7 t I 50% 150% 100% 200% L S I I3 steady state start-up I4 t4 t I t t I t I I7 t7 t I 50% 150% 100% 200% L S I I3 I4 t4 I2 t2 t I t I t I t I t I I I1 t1 10 Emax 2 | ABB Zone1Zone2Zone3 Ekip Touch (G ext - ANSI 51G & 50 GTD): (t = k) (t = k/l2 ). pre-alarm 90% . / . : 50%, 100% 200% . L, S I. : S, I G , (inrush currents) (, , ..). 100 ms 30 s . (IU ANSI 46): (t = k), . (zone selectivity) S G (ANSI 68): . , . "" . . , , ( ), . . (t = k). : 4 Ekip Touch L . Emax 2 Ekip Signalling. Power Controller: () Ekip Measuring (module). 10. U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 1SDC200467F001 ABB | Emax 2 11 (UV - ANSI 27): (t = k). (). (OV - ANSI 59): (t = k). () (UF - ANSI 81L): (t = k). (). (OF - ANSI 81H): (t = k). (). Ekip Measuring Pro Ekip Touch Ekip Measuring Pro. , Ekip Touch , . 11. L1 L2 L3 N LOAD PE U, f, M RP U14 f t f V1 f13 t13 U1 U2 U3 mean t12 OF voltage unbalance V3 V2 senso ciclico t12 U8 t8 U14 t f t f t V t V V1 U9 t8 f13 t13 U1 U2 U3 mean Extremely Inverse Very Inverse Standard Inverse t I 8 UV OV f12 t12 UF OF voltage unbalance V3 V2 senso ciclico t9 t12 12 Emax 2 | ABB Ekip Touch (VU ANSI 47): (t = k). . (Rc ANSI 64 & 50 NTD): (t = k). Ekip Touch. . G Gext. (RP - ANSI 32R): . Ekip ouch . . Synchrocheck (SC - ANSI 25): Emax 2. Ekip Touch . : 1. Ulive 2. U 3. f 4. 5. tsyn 6. (dead busbar): 1. Ulive 2. Udead 3. , , . (ANSI 47): , (alarm). (ANSI 78): (threshold), Ekip Touch . 12. 1SDC200468F0011SDC200469F001 1SDC200470F001 ABB | Emax 2 13 Ekip Touch RMS (L1, L2, L3) (N) 1% 0,2...1,2xIn IEC 61557-12. 0,03...16xIn In . Ekip Touch 0-125%. , 0-125% x In . Ekip Touch . pre-alarm, , . . . , 100 A. Ekip Measuring Ekip Measuring Pro ( Emax 2), : : -, - ( 0,5%) : , , ( 2%) : , , ( 2%) ( 0,2%) Ekip Touch (trend) . , / . 24 (smartphone, tablet ..). Data logger Ekip Touch Data Logger trip alarm. PC Ekip Connect. 13. 1SDC200471F001 14 Emax 2 | ABB Ekip Touch, : (, , ) , iTest, . Emax 2, Ekip Touch : , , 30 , 200 (.: / , pre-alarms, ..) : , , (firmware version) Ekip Touch Ekip Connect smartphone, tablet PC ( Ekip T&P Ekip Bluetooth ). Emax 2 ( , , ) . , LED . , Ekip Dip ( ) / ( ANSI BF). , (OT - overtemperature), ( ). : LED -20 C +70 C alarm Ekip Touch 14. 1SDC200472F0011SDC200473F001 ABB | Emax 2 15 Ekip Touch, . , . , , , , . home iTest . '''' '''' , (password). 0001 . LED: - LED pre-alarm ( ) - LED alarm (, ) LED , . 15. 16 Emax 2 | ABB (modules) Emax 2 : IEC 61850 Modbus TCP Modbus RS-485 Profibus Profinet DeviceNet EtherNet/IP Emax 2 (, alarm, ..) . , Ekip Com Actuator - . (test) : Ekip TT Ekip T&P (report) iTest Ekip Touch 16. ABB | Emax 2 17 Ekip Touch , . . . (module) Ekip Supply : Ekip Signalling Ekip Com Ekip Multimeter Ekip Control Panel G 100 A 0,2 In Ekip 24-48 VDC 110-240 VAC/DC 21,5-53 VDC 105-265 VAC/DC ( ) 10 W max. 10 W max. Inrush current 10 A 5 ms 10 A 5 ms 17. 1 8 2 3 4 5 7 6 1SDC200470F001 1SDC200474F001 18 Emax 2 | ABB Ekip Hi-Touch Ekip Hi-Touch ABB Emax 2. Hi-Touch , (Network analyzer) . Ekip Hi-Touch Ekip To