3
Discharge Time- Constants •Basis : EDMS 90327 (Voltage Withstand levels) & EDMS 1011223 (Quench Back) •Dipoles have an inductance of 154 * 0.1 H per sector •Dipoles have 2 times 3 resistors of 0.225 in parallel MP3 15.July 09, KHM 4 Configuratio ns are possible.
-
Upload
damian-snow -
Category
Documents
-
view
29 -
download
0
description
Discharge Time-Constants. Basis : EDMS 90327 (Voltage Withstand levels) & EDMS 1011223 (Quench Back) Dipoles have an inductance of 154 * 0.1 H per sector Dipoles have 2 times 3 resistors of 0.225 in parallel. 4 Configurations are possible. Dipoles. Dump Overheating. - PowerPoint PPT Presentation
Transcript of Discharge Time-Constants
MP3 15.July 09, KHM
Discharge Time-Constants
•Basis : EDMS 90327 (Voltage Withstand levels) & EDMS 1011223 (Quench Back)
•Dipoles have an inductance of 154 * 0.1 H per sector•Dipoles have 2 times 3 resistors of 0.225 in parallel
4 Configurations are possible.
MP3 15.July 09, KHM
τ
1900 Volt Limit
1500 Volt Limit (Switch)
Operational Limit
Dump Overheating
Quench Detection LimitVoltage/Dipole
Dipoles
MP3 15.July 09, KHM
Quadrupoles
τ
Quench Protection Limit is off scale
Operational Limit & Switch Limit (can be modified) Ultimate Limit (ELQA)
Inductance: 51*5.6 mH, Rdump: 9.2 mΩ + RaddNo overheating of existing resistors, Switch limit & operational =200 V, ELQA: 240 VQPS to be modified