Version GMM phasecut compact Signaleingänge lt. … ·  · 2016-05-03M7 3~ M Θ M4 3~ M Θ M8...

1
GMM phasecut compact 1 0 7 6 8 9 3 4 1 2 5 Mounting location GMM phasecut compact Page: Approved: Higher-level function Checked: + = Previous Page: 17.02.2014 Date Name Name Date Controls 2014.02.25, Musterplan phascut compact Next Page: Güntner GmbH & Co. KG Hans-Güntner-Str. 2 - 6 D-82256 Fürstenfeldbruck Model Range: Model Type: Created Version Total Pages: 1 jwohlman Einspeisung Power Supply GMM phasecut compact 100/1.1 GMM phasecut compact 240/4.1 Version GMM phasecut compact M1 3~ M Θ 3~ M Θ M5 3~ M Θ M2 3~ M Θ M6 3~ M Θ M3 3~ M Θ M7 3~ M Θ M4 3~ M Θ M8 OUT1 Schwellwert / Bypass Betrieb Threshold / Run Bypass In Betrieb Run Keine Warnung No Warning Kein Fehler No Error S1 - Freigabe / Release S2 - Nachtbegrenzung / Night Limit S3 - Sollwertumschaltung / Setting 2 Sig- +Ub B1 bu bn Signaleingänge lt. Betriebsanleitung Signal input according to manual B2 Drucksensor Pressure Transmitter 4-20 mA *Sensor Option Rückmeldung Drehzahl Feedback motor speed 0 - 10V / 0-100% OUT2 OUT3 OUT4 TB1 TB2 TB3 TB4 TB5 GMM phasecut compact 100/2.1 Gruppe 1 / Group 1 Gruppe 2 / Group 2 Gruppe 3 / Group 3 Gruppe 4 / Group 4 Einspeisung / Mains ON OFF Erdung am Gerät Grounding on Device TERM 1) 1) 1) 1) 1) 1) 1) 1) 1) Bei ungenutzten Abgängen sind die Thermokontaktanschlüsse zu brücken. / If no motor is connected, the thermal contacts clamps have to be bridged. Temperatursensor Temperature sensor KTY81-210 externe Ansteuerung External Control Value 0-10V/0-100% Sig- +Ub bu bn Drucktransmitter (4-20mA) oder Temperatursensor (KTY81-210), im Setup einstellbar. Preasure-Transmitter (4-20mA) or Temperature Sensor (KTY81-210), selectable by setup. B2 oder / or Temperatursensor Temperature Sensor KTY81-210 Drucksensor Pressure Transmitter 4-20 mA bn wh B2 *Sensor Option N1 41 42 44 31 32 34 21 22 24 UV W PE TB1 TB2 TK1A TK1B PE1 U1 V1 W1 U V W PE TB1 TB2 TK5A TK5B PE5 U5 V5 W5 U V W PE TB1 TB2 TK2A TK2B PE2 U2 V2 W2 U V W PE TB1 TB2 TK6A TK6B PE6 U6 V6 W6 U V W PE TB1 TB2 TK3A TK3B PE3 U3 V3 W3 UV W PE TB1 TB2 TK7A TK7B PE7 U7 V7 W7 U V W PE TB1 TB2 TK4A TK4B PE4 U4 V4 W4 UV W PE TB1 TB2 TK8A TK8B PE8 U8 V8 W8 PE PE L3 L2 L1 +24V1 +24V2 GND1 GND2 GND3 11 12 14 NC OUT1 0-10V AO1 GND4 OUT2 0-10V AO2 GND5 24V3 Release DI1 Night Limit DI2 Setting 2 DI3 24V4 S1 S2 S3 24V5 GND6 IN 4-20mA AI1 IN 4-20mA / KTY81-210 AI2 KTY81-210 AI3 IN 0-10V AI4 bn wh B3 B4 24V6 24V7 24V8 GND7 CAN High CH CAN Low CL A1 WM1 5 4 1 2 3 GN/YE WM5 5 4 1 2 3 GN/YE WM2 5 4 1 2 3 GN/YE WM6 5 4 1 2 3 GN/YE WM3 5 4 1 2 3 GN/YE WM7 5 4 1 2 GN/YE WM4 5 4 1 2 3 GN/YE WM8 5 4 1 2 3 GN/YE W1 1 2 3 GN/YE . PE PE DEVICE GND S - + S GND L1 L2 L3 PE

Transcript of Version GMM phasecut compact Signaleingänge lt. … ·  · 2016-05-03M7 3~ M Θ M4 3~ M Θ M8...

Page 1: Version GMM phasecut compact Signaleingänge lt. … ·  · 2016-05-03M7 3~ M Θ M4 3~ M Θ M8 OUT1 ... Pressure Transmitter 4-20 mA *Sensor Option Rückmeldung Drehzahl ... Setting

GMM phasecut compact

10 76 8 93 4

1

2 5

Mounting location

GMM phasecut compact

Page:

Approved: Higher-level function

Checked:

+

=

Previous Page:

17.02.2014

Date Name NameDate

Controls

2014.02.25, Musterplan phascut compact Next Page:

Güntner GmbH & Co. KGHans-Güntner-Str. 2 - 6D-82256 Fürstenfeldbruck

Model Range: Model Type: Created

Version Total Pages: 1jwohlman

EinspeisungPower Supply

GMM phasecut compact 100/1.1

GMM phasecut compact 240/4.1

Version GMM phasecut compact

M1

3~M

Θ

3~M

Θ

M5

3~M

Θ

M2

3~M

Θ

M6

3~M

Θ

M3

3~M

Θ

M7

3~M

Θ

M4

3~M

Θ

M8

OUT1

Schwellwert /Bypass BetriebThreshold / Run Bypass

In BetriebRun

Keine WarnungNo Warning

Kein FehlerNo Error

S1 - Freigabe / ReleaseS2 - Nachtbegrenzung / Night LimitS3 - Sollwertumschaltung / Setting 2

Sig-+Ub

B1

bubn

Signaleingänge lt. BetriebsanleitungSignal input according to manual

B2

DrucksensorPressure Transmitter

4-20 mA

*SensorOption

Rückmeldung DrehzahlFeedback motor speed

0 - 10V / 0-100%

OUT2 OUT3 OUT4

TB1 TB2 TB3 TB4 TB5

GMM phasecut compact 100/2.1

Gruppe 1 / Group 1 Gruppe 2 / Group 2 Gruppe 3 / Group 3 Gruppe 4 / Group 4 Einspeisung / Mains

ON

OFF

Erdung am Gerät

Grounding on Device

TERM

1) 1) 1) 1) 1) 1) 1) 1)

1) Bei ungenutzten Abgängen sind die Thermokontaktanschlüsse zu brücken. / If no motor is connected, the thermal contacts clamps have to be bridged.

TemperatursensorTemperature sensor

KTY81-210

externe AnsteuerungExternal Control Value

0-10V/0-100%

Sig- +Ub

bu bn

Drucktransmitter (4-20mA) oderTemperatursensor (KTY81-210),im Setup einstellbar. Preasure-Transmitter (4-20mA) or Temperature Sensor (KTY81-210), selectable by setup.

B2

oder / or

TemperatursensorTemperature Sensor

KTY81-210

DrucksensorPressure Transmitter

4-20 mA

bnwh

B2

*Sensor Option

N1

41

42

44

31

32

34

21

22

24

U V WPE

TB1 TB2

TK1A

TK1B

PE1

U1

V1

W1

U V WPE

TB1 TB2

TK5A

TK5B

PE5

U5

V5

W5

U V WPE

TB1 TB2

TK2A

TK2B

PE2

U2

V2

W2

U V WPE

TB1 TB2

TK6A

TK6B

PE6

U6

V6

W6

U V WPE

TB1 TB2

TK3A

TK3B

PE3

U3

V3

W3

U V WPE

TB1 TB2TK7A

TK7B

PE7

U7

V7

W7

U V WPE

TB1 TB2

TK4A

TK4B

PE4

U4

V4

W4

U V WPE

TB1 TB2

TK8A

TK8B

PE8

U8

V8

W8

PE

PE

L3

L2

L1

+24V1

+24V2

GND1

GND2

GND3

11

12

14

NC

OUT1 0-10V

AO1

GND4

OUT2 0-10V

AO2

GND5

24V3

Release

DI1

Night Limit

DI2

Setting 2

DI3

24V4

S1 S2 S3

24V5

GND6

IN 4-20mA

AI1

IN 4-20mA / KTY81-210

AI2

KTY81-210

AI3

IN 0-10V

AI4

bnwh

B3 B4

24V6

24V7

24V8

GND7

CAN High

CH

CAN Low

CL

A1

WM1 54 1 2 3GN/YE

WM5 54 1 2 3GN/YE

WM2 54 1 2 3GN/YE

WM6 54 1 2 3GN/YE

WM3 54 1 2 3GN/YE

WM7 54 1 2GN/YE

WM4 54 1 2 3GN/YE

WM8 54 1 2 3GN/YE

W1 1 2 3 GN/YE

.

PE

PE

DEVICE

GNDS

- +

S GND

L1 L2 L3 PE