Nano Cable G652D - DATAWARE - We connect worlds :: Home€¦ · 1 of 3 . Nano Cable G652D . Fibre...
Click here to load reader
Transcript of Nano Cable G652D - DATAWARE - We connect worlds :: Home€¦ · 1 of 3 . Nano Cable G652D . Fibre...
1 of 3
Nano Cable G652D
Fibre Cables
Product Summary • Nano TB: Tight buffered Nano-cable • Fibre Type: G652D single mode, G651D multi mode (62.5μm or 50μm) • Inner Layer: Resin • Outside Sheath: Low friction plastic • Fibre Count: 2, 4, 6, 8, 12
Photo/Drawing
1. Optical Fibre 2.Resin 3.Fibre Filler 4.Low Friction Sheath 5.Groove
Technical Specifications
Cable Properties
2 Fibres 4 Fibres 6 Fibres 8 Fibres 12 Fibres Outer Diameter (mm) 1.15±0.05 1.15±0.05 1.35±0.05 1.50±0.05 1.65±0.05 Weight (g/m) 1.0 1.0 1.6 1.8 2.0 Min Bend diameter(mm) 50 50 60 80 80 Unit Colour Green Green Green Green Green
2 of 3
Optical Parameters (Fibre Unit):
Parameters SM G652D MM 62.5/125 0.50dB/km max @1310nm
0.35dB/km max @1550nm 3.5dB/km max @850nm 1.5dB/km max @1300nm
Fibre Colour Code
No. 1 2 3 4 5 6 7 8 9 10 11 12 Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
2 Fibres:1~2 colours, 4 Fibres:1~4 colours, 6 Fibres:1~6 colours, 8 Fibres:1~8 colours, 12 Fibres:1~12 colours
Test Protocol
Mechanical Test:
Test Standard Parameters Criteria Tension performance IEC 60794-1-2-E1 Load is 1×W
Fibre Strain ≤0.4% at MAX Additional Attenuation ≤0.05dB Fibre Strain ≤0.05%, after test
Bend IEC 60794-1-2-E11A Diam. 40mm×3turns, 5 cycles at 20°C
Additional Attenuation ≤0.05dB, after test
Crush IEC 60794-1-2-E3 100 N, 60s Additional Attenuation ≤0.05dB, after test
Note: 1. Tests according to IEC 60794 Edition 1.0, 2008-10 2. All optical testing proceeded at 1550 nm
Environmental Test:
Test Standard Parameters Criteria
Temperature cycling
IEC 60794-1-2-F1
+20°C, -40°C, +60°C, (3 cycles)
Absolute Attenuation ≤0.5dB/km, during test Absolute Attenuation ≤0.1dB/km, after test
Water Soak IEC 60794-5 1000 hours in water, 18°C~22°C
(Test after temp cycle) ≤0.07dB/km Change compared to start value
Damp Heat Cycle IEC 60068-2-38 25°C, 65°C, 25°C, 65 °C, 2 5 °C, -10 °C, 25°C
Absolute Attenuation ≤0.5dB/km, during test Absolute Attenuation ≤0.1dB/km, after test
Note : 1. Tests according to IEC 60794 Edition 1.0, 2008-10 2. All optical testing proceeded at 1550 nm
3 of 3
Blowing Test 2 Fibres 4 Fibres 6 Fibres 8 Fibres 12 Fibres Test Equipment ERICSSON/F, B3FT/ FBT-1.1 Standard Duct 5/3.5 mm Typical Blowing Length ≥ 1000 m ≥ 1000 m ≥ 1000 m ≥ 1000 m ≥ 800 m
Ordering Information:
Packing: Rotated in the pan
Delivery Lengths: Standard delivery lengths are 1000m, 2000m, 3000m, with a tolerance of 0~+0.5%.
Part Number
30-1002-137-0 Nanocable 2-core, G652D 30-1004-136-0 Nanocable 4-core, G652D 30-1006-138-0 Nanocable 6-core, G652D 30-1008-140-0 Nanocable 8-core, G652D 30-10012-139-0 Nanocable 12-core, G652D