FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V /...

36
14 / Up to 5 collectors Up to 10 collectors Empty mass Kg 46 Working pressure bar 6 Collector pipe diameter mm 18 Amount of collector liquid l 2,1 Absorption % 95 Emission % 5 Aperture surface m 2 2,26 Absorbent surface m 2 2,24 Specific thermic capacity kJ/K 15,32 η 0 0,81* k 1 W/m 2 K 3,13* k 2 W/m 2 K 2 0,016* T stagnation °C 198 * data refers to the aperture area KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V CODE 3020058 FLAT SOLAR COLLECTOR Solar collector for forced circulation PERFORMANCES • Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems; • The blue selective surface treatment forgives very high performances with the 95% absorbtion and only 5% reflection; • The collectors’ increased surface gives the possibilty to produce even more domestic hot water; • The laser welding technology guarantees a very smooth absorbing surface, maximizing the exploitation of the solar energy; • The back and lateral insulation, with very low conductivity (only 0.035 W/mK), ensures higher efficiency; • Thanks to the high transparent glazed covering, with an internal microprismatic treatment, the reflections are reduced;

Transcript of FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V /...

Page 1: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

14 /

Up to 10 collectors Up to 5 collectors

Up to 10 collectors Up to 5 collectors

Up to 10 collectors Up to 5 collectors

Empty mass Kg 46

Working pressure bar 6

Collector pipe diameter mm 18

Amount of collector liquid l 2,1

Absorption % 95

Emission % 5

Aperture surface m2 2,26

Absorbent surface m2 2,24

Specific thermic capacity kJ/K 15,32

η0

0,81*

k1 W/m2K 3,13*

k2 W/m2K2 0,016*

T stagnation °C 198

* data refers to the aperture area

KAIROS XP 2.5-1V / 2.5-1H

TECHNICAL DATA KAIROS XP 2.5-1V

CODE 3020058

FLAT SOLAR COLLECTOR

Solar collector for forced circulation

PERFORMANCES

• Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems;

• The blue selective surface treatment forgives very high performances with the 95% absorbtion and only 5% reflection;

• The collectors’ increased surface gives the possibilty to produce even more domestic hot water;

• The laser welding technology guarantees a very smooth absorbing surface, maximizing the exploitation of the solar energy;

• The back and lateral insulation, with very low conductivity (only 0.035 W/mK), ensures higher efficiency;

• Thanks to the high transparent glazed covering, with an internal microprismatic treatment, the reflections are reduced;

Page 2: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 15

(Tcollector liquid average

-Tenvironment

)/G K/(W/m2)

G = 1000 W/m2

Ppeak=1.832 W

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

1,0

0,9

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,0

Solar collector efficiency curve

Eff

icie

ncy

1010

1128

2241

61

98Up to 10 collectors Up to 5 collectors

1010

1128

2241

61

98Up to 10 collectors Up to 5 collectors

Empty mass Kg 46

Working pressure bar 6

Collector pipe diameter mm 18

Amount of collector liquid l 2,5

Absorption % 95

Emission % 5

Aperture surface m2 2,26

Absorbent surface m2 2,23

Specific thermic capacity kJ/K 17,98

η0

0,81*

k1 W/m2K 3,02*

k2 W/m2K2 0,017*

T stagnation °C 193

* data refers to the aperture area

TECHNICAL DATA KAIROS XP 2.5-1H

CODE 3020057

FLAT SOLAR COLLECTOR

QUALITY

• Kairos Thermo HF is made up with the best material available: the copper hydraulic circuit and the anodized aluminium chassis guarantee high reliabilty, corrosion proof and very long life cycle;

• The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading;

• The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process;

• With the solar key mark and the test report according EN 12975-2, the compliance with the international standard is certified;

DESIGN AND TECHNOLOGY

• Kairos XP 2.5-1 offers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape;

• The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit;

• Kairos XP 2.5-1 is availbel in two versions that allow vertical and horizontal installation;

• Additional accessories allow the built-in installation;

Page 3: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

16 /

Tcollector liquid average

-Troom

/G K/(W/m2)

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

1,0

0,9

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,0

Solar collector efficiency curve

Eff

icie

ncy

Empty weight kg 35

Working pressure bar 6

Collector pipe diameter mm 18

Amount of collector liquid l 1,0

Absorption % 95

Emission % 5

Aperture surface m² 1,82

Absorbent surface m² 1,74

Specific heat capacity kJ/K 13

η0 0,74*

k1 W/m²K 3,43*

k2 W/m²K² 0,008*

stagnation T °C 182,3

* data referring to the aperture area

KAIROS CF 2.0

FLAT SOLAR COLLECTOR

• Absorber with highly selective treatment to titanium oxides (95% absorption 5% emission)

• Hail-proof anti-reflective glass

• Hydraulic circuit with copper pipes

• Harp geometry and continuous ultrasound welding

• Designed and sized for functioning in systems with forced circulation

• Can be inclined between 30° and 60°

• Test report according to en 12975

TECHNICAL DATA KAIROS CF 2.0

CODE 3020055

Solar collector for forced circulation

Page 4: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 17

(Tcollector liquid average

-Tenvironment

)/G K/(W/m2)

G = 1000 W/m2

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

1,0

0,9

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,0

Solar collector efficiency curve

Eff

icie

ncy

Ppeak=1.740 W

Rule of composition of the line with temperature probe:a row of n manifolds consists of a solar collector Kairos VT 20 B and n-1 solar collectors Kairos VT 20 E.

1840 mm

1910

mm

140 mm

Up to 6 collectors

Up to 3 collectors

Empty mass kg 68

Working pressure bar 6

Amount of collector liquid lt 5.7

Absorption % 92

Emission % 8

Aperture surface m2 2,12

Absorbent surface m2 2,01

η0 0.82*

k1 W/m2K 2.82*

k2 W/m2K2 0.0047*

T stagnation °C 206,1

* data refers to the aperture area

TECHNICAL DATA SOLAR COLLECTORKAIROS VT 20

KAIROS VT 20 B KAIROS VT 20 E

CODE 3023497 3021022

KAIROS VT 20

VACUUM TUBE SOLAR COLLECTOR

• Aluminium blue selective and adjusta-ble absorber with concentric tube

• Very high transparency borosilicate vaccum single glass

• Structure with insulated technopolymer

• Connections with idler screw nut

• Integrated solar probe hole

• Vertical, horizontal, ground and sloped roof installation

Solar collector for forced circulation

Page 5: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

18 /

COMPOSITION OF THE ROWS OF SOLAR COLLECTORS

KAIROS CF 2.0 1 2 3 4 5 6

Description Code TT TR TT TR TT TR TT TR TT TR TT TR

Hydraulic fittings kit for 1 collector forced circ.CF 3024017 1 1 1 1 1 1 1 1 1 1 1 1

Hydraulic fittings kit for CF extension 3024018 1 1 2 2 3 3 4 4 5 5

Roof frame for 1 collector forced circulation CF 3024014 1 1 1

Roof frame for 2 collectors forced circulation CF 3024015 1 1 1

Extension roof frame for 2 collectors forcedcirculation CF

3024016 1 1 2 2

Horizontal bar CF 2.0 3024249 1 2 3 4 5 6

Triangle 3024103 2 2 3 4 5 6

TT

TT

TT

IN IN²

TO

TR

TR

TROO

Efficient products for the satisfaction of the user,easiness and flexibility of installation to help the installer: this perfect cou-pling characterizes our solar collectors and is one of the reason why Ariston’s solar products are choosen every year from millions of customer around the world.

The collectors of Ariston solar range can be installed on the ground or flat roof, on sloped roof and in-roof (Kairos XP 2.5-1 V only).

For any of the above mentioned installation possibility, the following tables are designed to help the installer and the end user choosing the correct installation and hydraulic accessories for any kind of solar collector.

Example of ground installation Example of sloped roof installation Example of in-roof installation (only Kairos XP 2.5 V)

Page 6: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 19

KAIROS XP 2.5-1V

1 2 3 4 5 6 7 8 9 10

Description Code TT TR IN TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN²

KAIROS XP 2.5-1 V 3020046 1 1 1 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 10 6 6 6 12 7 7 7 14 8 8 8 16 9 9 9 18 10 10 10 20

Hydraulic connection set 1 collector

3024093 1 1 1 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2

Hydraulic connection set 1 collector ext.

3024094 1 1 1 2 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 10 6 6 6 12 7 7 7 14 8 8 8 16 9 9 9 18

Horizontal Bars 3024104 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10

Triangle 3024103 2 2 3 4 5 6 7 8 9 10

Inox Fixing Straps* 3024112 2 3 4 5 6 7 8 9 10 11

In-roof kit(1 collector)

3721434 1

In-roof kit(2 collectors)

3721428 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

In-roof kit(additional collector)

3721429 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8

2nd row in-roof kit(2 collectors)

3721430 1 1 1 1 1 1 1 1 1

2nd row in-roof kit(additional collector)

3721431 1 2 3 4 5 6 7 8

TT

TT

IN IN²

TR

TR

KAIROS XP 2.5-1H 1 2 3 4 5 6 7 8 9 10

Description Code TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR

KAIROS XP 2.5-1 H 3020047 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10

Connection set 1 coll 3024093 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Connect set 1 additional coll XP 3024094 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9

Horizontal bars (XP 2.5-1 H) 3024106 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10

Triangle (XP 2.5-1 H) 3024105 2 3 4 5 6 7 8 9 10 11

Inox fixing straps* (pair) 3024112 2 3 4 5 6 7 8 9 10 11

TT

TT

IN IN²

TR

TR

* special fixing frame for sloped roof for xp collector

Description Code

Bent tile fixing brackets (pair) 3024113

Flat tile fixing brackets (pair) 3024114

Slate tile fixing brackets (pair) 3024083

Undulating roof fixing screws (pair) 3024115

Wooden roof fixing screws (pair) 3024116

Page 7: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

20 /

MINIMUM EXTERNAL TEMPERATURE / PERCENTAGE

KAIROSVT 20

1 2 3 4 5 6

Description Code TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR

Hydraulic kit for KAIROS VT extension 12043886 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5

Horizontal bar 3024250 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6

KAIROS VT roof bracket kit 3024147 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 5 6 6 6

Triangle 3024251 1 2 3 4 5 6

Safety bracket 3024254 1 2 3 4 5 6

-3°/10% -7°/20% -14°/30% -23°/40% -32°/50%

water glycol water glycol water glycol water glycol water glycol MIXTURE CONTENT

Nat

ura

l C

ircula

tion k

it l 150/1 18 2 15 5 15 5 - - - - 20

l 200/1 22.5 2.5 20 5 17.5 7.5 - - - - 25

l 200/2 22.5 2.5 20 5 17.5 7.5 - - - - 25

l 300/2 22.5 2.5 20 5 17.5 7.5 - - - - 25

Fo

rce

dC

ircula

tion k

it

l 200/2 CF1 12 1 10.5 2.5 9 4 8 5 6.5 6.5 13

l 200/2 CF2 8 1 7 2 6.5 2.5 5.5 3.5 4.5 4.5 9

l 300/2 CF1 16 2 14.5 3.5 12.5 5.5 11 7 9 9 18

l 300/2 CF2 16 2 14.5 3.5 12.5 5.5 11 7 9 9 18

l 400/3 CF2 20.5 2.5 18.5 4.5 16 7 14 9 11.5 11.5 23

l 500/4 CF2 25 3 22.5 5.5 19.5 8.5 17 11 14 14 28

Sup

ple

me

nta

ry C

F

kit co

nne

ctio

ns

18 - 5 m_pipe + 1 + 0 + 1 + 0 + 1 + 1 + 1 + 1 + 1 + 1 + 1

18 -10 m_pipe + 2 + 0 + 1.5 + 0.5 + 1.5 + 1 + 1 + 1 + 1 + 1 + 2

18 -20 m_pipe + 3.5 + 0.5 + 3 + 1 + 3 + 1 + 2.5 + 1.5 + 2 + 2 + 4

18 -30 m_pipe + 5.5 + 0.5 + 5 + 1 + 4 + 2 + 3.5 + 2.5 + 3 + 3 + 6

22 - 5 m_pipe + 2 + 0 + 1.5 + 0.5 + 1.5 + 0.5 + 1 + 1 + 1 + 1 + 2

22 -10 m_pipe + 2.5 + 0.5 + 2.5 + 0.5 + 2 + 1 + 2 + 1 + 1.5 + 1.5 + 3

22 -20 m_pipe + 5.5 + 0.5 + 5 + 1 + 4 + 2 + 3.5 + 2.5 + 3 + 3 + 6

22 -30 m_pipe + 8 + 1 + 7 + 2 + 6 + 3 + 5.5 + 3.5 + 4.5 + 4.5 + 9

TT

TT

TT

IN

TO

TR

TR

TROO

Page 8: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 21

ACCESSORIESAND COMPONENTS

Page 9: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

22 /

Solar system management accessories and devices Code

Sensys, modulating system manager (wired)- Remote control of all boiler functions through the BUS Bridgenet protocol - User-Friendly Setting/Configuration of system parameters- thermoregulation- Display of solar system working (if connected) - Display of energy reports (kWh), solar energy production, CO2 savings, storaged DHW- Modulating sensor for detecting of the room temperature- User-friendly daily and weekly scheduling of central heating - User-friendly daily and weekly scheduling of domestic hot water (only in case of only-heating boiler coupled to a tank)

3318585IT-EN-FR-ES-PT

3318613TK-RUS-GR-HR-

SRB

3318615PL-CZ-HU-RO

Solar Manager IZYControl unit equipped with liquid crystal display that can show and manage up to 10 types of solar plants. Four sensor inputs Pt1000, three relay outputs and two PWM to control variable speed circulators.The controller display the temperatures measured by the probes, diagnostic on-screen function testsystem, and anti-freeze function. Free Vbus and BACnet compatibility.Compatible with PRO datalogger DL2, DL3 DATALOGGER PRO INTERFACE LAN-SOLAR MANAGER PRO, PRO MODULE ALARM PROTECTION THE SURGE. Dimensions: 110 x 166 x 47 mm

3024340

Additional DHW solar probeCylinder probe with diameter of 6 mm Pt1000 Class B DIN with 1 metre of blue cable suitable formeasuring cylinder temperatures; range -50°C/+110°C. Compatible with Elios 25.

3024274

Additional collector solar probeCylinder probe with diameter of 6 mm Pt1000 Class B DIN with 1 metre of grey cable suitable formeasuring collector temperatures; range -50°C/+200°C. Compatible with Elios 25. Copper well andprobe-holder clamp included.

3024273

Digital thermostatDevice with input for probe and output for the actuation of a high voltage load at 250 V like a divertervalve with 2 or 3 wires. The three digit display allows to view the temperatures and the setting of thefunctioning parameters.Supplied cylindrical probe with diameter of 6 mm Ptc1000 with 1.5 metres of cable.Dimensions: 79 x 115 x 42 mm.

800232

Electrical resistance Flanged resistance kit for 1.5 kW single-phase natural circulation systems and 220 V power supply.Includes flange, magnesium anode, thermostat and small cap. Suitable for Kairos Thermo Direct (allversions) and Kairos Thermo HF (all versions).

107069

Enamelled electrical resistanceFlanged resistance kit for 2 kW single-phase natural circulation systems and 220 V power supply.Includes flange, magnesium anode, thermostat and small cap. Suitable for Kairos Thermo Direct (allversions) and Kairos Thermo HF (all versions).

3024272

Safety groupPre-assembled group including safety valve, automatic air release valve and manometer

12053830

heating return probe S4 3024175

Solar Accessories

Page 10: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 23

Hydraulic devices and accessories Code

Digital Solar Pump GroupPumping station for forced circulation plants, equipped with a safety, regulation and rinse unit, digital pressure and temperature sensors,electronic control board provided with a collector probe and two tank probes. Hydraulic connections in 18 mm or in 3/4” flat seal version. Dimensions: 275 x 480 mm.flow - return axles distance 125 mm.NB: system interface SENSYS to be ordered separately

3318905

Solar pump group 25-70Pumping station for forced circulation systems, equipped with safety unit, regulation and rinse unit.Hydraulic connections in 3/4” flat seal version.To be coupled to the solar pump unit 25-70 (AR) for management of systems with several cylindersor with several sets of collectors.Dimensions: 250 x 375 mm.

3024256

Solar pump unit 25-145Pumping station for large forced circulation systems, equipped with safety unit. Hydraulic connectionsin 3/4” flat seal version. Flexible tube and quick-coupling fitting for expansion vessel.

3024258

Thermostatic mixerBronze mixing valve designed for solar application able to supply constant temperature in a widerange of regulations with reaction times at extremely low thermal transients.Equipped with scald-proof mechanism, protection against calcification and corrosion.Dimensions: 115 x 74 mm.

3024085

GAL EVO motorized mixing valve (plus wires) 3024176

Motorized diverter valveDiverter valve for DHW integration management. 230 V power supply. Temperature of the fluid+1°C/+95°C, maximum functioning differential pressure 4 bar.3/4” male threaded connections.Dimensions: 94 x 130 x 68 mm.

3087085

Motorized three-way valvediverter motorized valve to use exclusively with Macc tank.Suitable with heating and domestic hot water. Includes wires.

3024076

GAL EVO motorized diverter valve 3024177

Fresh water stationDHW production module. Minimum flow rate 2,5 l/min.Maximum DHW flow rate 32 l/min. Adjustable temperature from 36 to 65 °C. Dimensions 700x400x295 mm

3024152

Recirculation kit FWS 3024161

Hydraulic kit COMBI 3024174

Page 11: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

24 /

Solar AccessoriesCode

18 lt solar expansion vessel 25 lt solar expansion vessel 35 lt solar expansion vessel 50 lt solar expansion vessel 80 lt solar expansion vessel150 lt solar expansion vessel 200 lt solar expansion vesselSuitable for use in closed heating systems with solar energy as per DIN 4757 and EN 12977. The vessel is equip-ped with a special membrane for solar systems, certified according to the DIN 4807-3 Standard, which separates the air side from the side containing the solar liquid. The fixing brackets allow stable and safe installation. Maximum pressure equal to 10 bar, System use temperature within -10°C/+99°C.

3024318302431930243203024321302432230243233024324

Generic solar plate heat exchanger 16kW Generic solar plate heat exchanger 32kW Generic solar plate heat exchanger 48kWBrazed steel plate heat exchanger, suitable for use with domestic hot water and heating. Operational pressure 5 bar, maximum operational temperatures 60/45 °Crespectively with exchange surfaces (m2)* / number of plates / acceptable volumetric flow rate (l/h) equal to 0.4 / 18 / 720; 0.8 / 34 / 1440; 1.2 / 48 / 2500

Solar heat exchanger for swimming pools 20kW Solar heat exchanger for swimming pools 40kW Solar heat exchanger for swimming pools 70kW*Titanium shell and tube heat exchanger, suitable for heating water in swimming pools. Operational pressure 2 bar. Primary/secondary operational flow rates (m3) respectively of 0.9/10; 1.7/15; 3/20.

302403630240373024038

302403930240403024041

Collector side hydraulic adaptation kitContains hydraulic fitting elements for smooth copper pipe measuring 16-18 and 22 mm and for connection with 3/4” flat seal.

Pump unit side hydraulic adaptation kit. Contains hydraulic fitting elements for smooth copper pipe measuring 16-18 and 22 mm and for connection with 3/4” flat seal.

Automatic air vent valve

3024070

3024071

3024158

Stainless steel roof passage pipes. Contains two flexible stainless steel pipes measuring 22 mm with isolation measuring 1 m. Connections for smooth copper pipe measuring 16-18 and 22 mm.

Twin pre-isolated pipes Kit containing 10 m of corrugated stainless steel dual piping with 16 mm diameter and preisolated. Collector probe cable is incorporated. A bronze fitting kit is supplied for connection to the collectors and the pumping station.

3024234

3024069

1/2” hydraulic safety unit3/4” hydraulic safety unit1” hydraulic safety unit1” siphon

877084877085885516877086

Instruments for filling and maintenance of the solar system Code

Pure anti-freeze liquid (5 lt) Non-toxic, odourless and hygroscopic propylene glycol. The corrosion inhibitors contained in the propylene glycol protect the metals normally used in solar installations. Can be mixed with water in all proportions between 25% and 75%.

800215

Anti-freeze liquid manual loading pump Bronze piston pump for connection to the solar system during the filling phase and pressurisation.

800235

Page 12: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 25

COLLECTIVE SOLAR SYSTEMS

Page 13: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

26 /

Solar system with 2 tanks,probes and a 1 three way valve

Solar system with 2 tanks,of which one is stratified

Solar system with 2 tanks,valve control and heat exchange

Solar system with 2 tanks andest/ovest collectors

Solar system with 3 tanks,valve control and priority logic

Solar system with 1 tank,1 swiming pool, collectors, 1 external heat exchanger, 1 three way valve

Solar system with 3 tanks,pump control and priority logic

Solar system with 2 tanks,1 external heat exchanger and pump control

General system diagrams

Page 14: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 27

SOLAR MANAGER PRO

• Menu simplified and quick to set-up

• 7 main schemes and + 20 variants

• 8 sensor inputs and 5 relay outputs

• 2 PWM or 0/10V signal to drive up to 2 modulating pumps

• Up to 2 extension modules via VBus® con-nectable (21 sensors and 15 relays in total)

• Irradiation based function to exploit solar energy

• Possibility to set up by remote or by SD card

• Measure and report of solar energy expoi-tation

• Compatible with ADEME Fond Chaleur (GRS) protocol

• Complete accessories range for basic and evolved functions

TECHNICAL DATA SOLAR MANAGER PRO

Inputs 8

Outputs 4 semiconductor relays, 1 potential-free relay, 2 PWM outputs

Power supply 230

Protection type 20

Ambient temperature 0 ÷ 40

Dimensions 198 x 170 x 43

170

43

198

2015

CODE 3024252

Page 15: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

28 /

Solar Manager PRO AccessoriesAccessories to manage the solar system Code

DATALOGGER DL3 PROWith the DL3 Pro you can easily and conveniently log system data of up to 6 controllers get a comprehensive overview of all controllers connected with the large full graphic display. Transfer data with an SD memory card, or use the LAN interface to view and process data on your PC.

3024276

DATALOGGER DL2 PROThis module enables the acquisition and storage of large amounts of data (such as measuring and balance values of the solar system) over a long period of time. System access is possible with just a few clicks via VBus.net For transmission of the data stored in the internal memory of the DL2 to a PC, an SD card can be used.

3024277

I/O EXTENSION MODULE 6-5 PROThe extension Module provides 5 additional relays and 6 additional sensor inputs. Up to 3 extension modules can be connected to the Solar Manager Pro via VBus®. The Extension Modules themselves do not require any adjustments, they are simply connected and assigned to the controller. The inputs and outputs of the registered modules will then be available for all functions of the controller.

3024279

IRRADIATION SENSOR PROThe solar cell is used for measuring the irradiation intensity. The short-circuit current rises with increasing irradiation intensity. The sensor can also be used for additional functions. The connecting cable can be extended to 100 m.

3024278

RPD SENSOR PROMeasure the temperature and the relative pressure with a single measuring element and then transmit the measured values directly. They can be optimally used for leakage and overpressure monitoring. Can be used in aggressive media as well as in domestic water and thus are ideal for the application in solar thermal and heating systems.

3024282

VFD SENSOR PRO SMALL The digital sensor measure the temperature and the flow rate with a single measuring Can be used in aggressive media as well as in domestic water and thus are ideal for measuring the flow rate and the heat quantity in solar thermal and heating systems. VFD Pro Small has an operative flow range 1-12l / 25-80°C MaxT 100°C (120°C short).

3024280

VFD SENSOR PRO BIG The digital sensor measure the temperature and the flow rate with a single measuring Can be used in aggressive media as well as in domestic water and thus are ideal for measuring the flow rate and the heat quantity in solar thermal and heating systems. VFD Pro big has an operative flow range 2-40l/ 25-80°C MaxT 100°C (120°C short).

3024281

SOLAR MANAGER PROBE - COLLECTORProbe for collectors, related to PRO electronics

3024273

SOLAR MANAGER PROBE - CYLINDERSProbe for cylinders, related to PRO electronics

3024274

SOLAR MANAGER PROBE - CUFF TUBEProbe for PRO electronics, to be applied on the pipes

3024275

OVERVOLTAGE PROTECTIONThe device should be used in order to protect the susceptible temperature sensors in or at the collector against induced overvoltages. In the case of local thunderstorms, voltage peaks which could destroy the sensor can be induced in the sensor cable. The protector diodes in the Overvoltage protection limit these overvoltages to a value harmless to the sensor. The best way to protect the sensor is to install this connecting box close to the sensor.

3024284

LAN INTERFACE - SOLAR MANAGER PROIt is designed for the direct connection of the controller to a PC or router. It enables easy access to the controller via the local network of the owner. Thus, controller access, system parametrisation and data read-out can be effected from every workstation of the network.

3024283

ALARM MODULE PROIt is to be connected to the VBus® of the controller and issues an optical signal via the red LED if a failure has occurred. It has a potential-free relay output, which can e.g. be connected to a building management system (BMS) to issue a general warning in the case of a system failure.

3024292

Page 16: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 29

0 200 400 600 800 1000 1200

14,013,012,011,010,09,08,07,06,05,04,03,02,01,00,0

137,2

127,4

117,6

107,8

98

88,2

78,4

68,6

58,8

48

39,2

29,4

19,6

9,8

0

Re

sid

ua

l lo

ss [

kp

a]

Re

sid

ua

l lo

ss [

m.c

.a.]

Capacity [m³/h]

Wilo Yonos PARA ST 15/7 PWM

Pump Group Pro 20-70

PUMP GROUP PRO 20-70

53 100

205

334 150

60

386

332

732

0

TECHNICAL DATA PUMP GROUP PRO 20 - 70

Max. admissible pressure PN 10Max. operating temperature 120 °CMax. short-time temperature 160 °C, < 15 minutesMax. propylene glycol content 50%Pressure relief valve 6 barsPressure gauge 0 - 6 barsCheck valves 2x200 mm wcValves and fittings BrassGaskets EPDMCheck valves BrassInsulation 0,041 W/(m K)

2015

• Compact size

• External PPS casing

• High efficiency pumps

CODE 3024256

For the whole accessory list see page 54

Page 17: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

30 /

0 250 500 750 1000 1250 1500 1750 2000 2250 2500

15,014,013,012,011,010,09,08,07,06,05,04,03,02,01,00,0

147,0137,2127,4117,6107,898,088,278,468,658,849,039,229,419,69,80,0

Re

sid

ua

l lo

ss [

kp

a]

Re

sid

ua

l lo

ss [

m.c

.a.]

Capacity [m³/h]

Grundfos Solar PML 25-145

Pump Group Pro 25-145

336 158

63205

436

416 47

4

12

53 100

TECHNICAL DATA PUMP GROUP PRO 25-145

Max. admissible pressure PN 10Max. operating temperature 120 °CMax. short-time temperature 160 °C, < 15 minutesMax. propylene glycol content 50%Pressure relief valve 6 barsPressure gauge 0 - 6 barsCheck valves 2x200 mm wcValves and fittings BrassGaskets EPDMCheck valves BrassInsulation 0,041 W/(m K)

PUMP GROUP PRO 25-145

2015

For the whole accessory list see page 54

• Compact size

• External PPS casing

• High efficiency pumps

CODE 3024258

Page 18: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 31

167

99

171 220

674 298602

500

271

98

120

829

795

TECHNICAL DATA SOLAR STATION PRO

Maximum pressure primary side bar 6Maximum pressure secondary side bar 10Maximum temperature primary side °C 120Maximum temperature secondary side °C 95Number of plates exchanger 60Sensors installed 3 x Pt1000Sensors in the packaging 2 x Pt1000

2015

SOLAR STATION PRO

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2 2,401

23456789

101112131415

0,09,8

19,629,439,249,058,868,678,488,298,0107,8117,6127,4137,2147,0

Grundfos Solar PML 25-145

Grundfos UPML 25-105 N

Solar Station Pro - prim.Solar Station Pro - sec.

Pre

va

len

za r

esi

du

a [

kp

a]

Pre

va

len

za r

esi

du

a [

m.c

.a.]

Portata [m³/h]

For the whole accessory list see page 54

• Compact size

• External PPS casing

• High performing Plate exchanger

• High efficiency pumps on Solar and secon-dary circuits

• DHW compliancy

• Solar Manager Pro embedded

CODE 3024261

Page 19: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

32 /

120

110

100

90

80

70

60

50

40

30

20

10

0

280

260

240

220

200

180

160

140

120

100

80

60

40

20

0

Po

we

r [k

W]

Tap

ca

pa

city

[l/

min

]

Water temperature at the tap: 45°CWater temperature at production: 60°CCold water temperature: 10°C

90 °C80 °C

70 °C

65 °C

FWS PRO MIDI

STORAGETANKTEMPERATURE

FWS PRO MIDI

B

500

A

795

167

95

120271321

108564265

52

172 777 201

670

12227

14054

287

670

1254

297

1 1/2” G947

50 1 1/

2” G

90 1“ G1“

G

9611379

115064 63

TECHNICAL DATA FWS PRO MIDI

SINGLE INSTALLATION SCHEME CASCADE INSTALLATION SCHEME

Maximum pressure primary side bar 6Maximum pressure secondary side bar 10Maximum temperature °C 95Number of plates exchanger 40

2015

For the whole accessory list see page 54

• External PPS casing

• High performing Plate exchanger

• Instantaneous DHW production reduce bacteria risks

• ACS and DM174 compliancy

• Controller embedded

CODE 3024263

Page 20: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 33

120

110

100

90

80

70

60

50

40

30

20

10

0

280

260

240

220

200

180

160

140

120

100

80

60

40

20

0

Po

we

r [k

W]

Tap

ca

pa

city

[l/

min

]

Water temperature at the tap: 45°CWater temperature at production: 60°CCold water temperature: 10°C

90 °C80 °C

70 °C

65 °C

FWS PRO MAXI

STORAGETANKTEMPERATURE

FWS PRO MAXI

B

500

A

795

167

95

120271321

108564265

52

172 777 201

670

12227

14054

287

670

1254

297

1 1/2” G947

50 1 1/

2” G

90 1“ G1“

G

9611379

115064 63

TECHNICAL DATA FWS PRO MAXI

SINGLE INSTALLATION SCHEME CASCADE INSTALLATION SCHEME

Maximum pressure primary side bar 6Maximum pressure secondary side bar 10Maximum temperature °C 95Number of plates exchanger 60

2015

For the whole accessory list see page 54

• External PPS casing

• High performing Plate exchanger

• Instantaneous DHW production reduce bacteria risks

• ACS and DM174 compliancy

• Controller embedded

CODE 3024264

Page 21: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

34 /

Devices and accessories for solar collectors Code

CIRCULATION KIT FWS PRO MIDI-MAXI 3024265

CASCADE KIT FWS PRO MIDI 3024268

CASCADE KIT FWS PRO MAXI 3024269

CIRCULATION KIT FWS PRO MIDI CASCADE 3024270

CIRCULATION KIT FWS PRO MAXI CASCADE 3024271

3-WAY VALVE PRO - DN 20Destratification valve to install SOLAR STATION PRO

3024262

3-WAY VALVE PRO - DN 25Destratification valve to install single FWS PRO MIDI

3024266

3-WAY VALVE PRO - DN 32 Destratification valve to install single FWS PRO MAXI

3024267

3-WAY VALVE PRO - DN 40 Destratification valve to install FWS PRO MIDI in cascade

3024325

RPR SENSOR PRO - PRESSURE SENSOR 3024326

Solar Accessories

Page 22: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 35

Devices and accessories to manage solar system Code

SOLAR MANAGER IZYUnit equipped with liquid crystal display that can display and manage up to 10 types of solar plant. Four sensor inputs Pt1000, three relay outputs and two PWM outputs to control variable speed circulators. Supplied three probes, two for cylinder and one for the collector. The controller has display the temperatures measured by the probes, diagnostic on-screen function test system, and anti-freeze function. Free Vbus and BACnet compatibility.Compatible with PRO datalogger DL2, DL3 DATALOGGER PRO INTERFACELAN-SOLAR MANAGER PRO, and PRO MODULE ALARM PROTECTION THE SURGE. Dimensions: 110 x 166 x 47 mm.

3024340

SOLAR MANAGER PROBE - COLLECTORProbe for solar collector, to be added on PRO electronics

3024273

SOLAR MANAGER PROBE - CYLINDERSProbe for cylinders, to be added on PRO electronics

3024274

SOLAR MANAGER PROBE - CUFF FOR PIPEProbe for PRO electronics to be added on pipes

3024275

SOLAR MANAGER CONTROL CARDCard for the complete management of a solar thermal system with forced circulation.Installation parameters completely configurable through system interfaceSENSYS (not supplied). It includes three temperature sensors NTC 10KB = 3977 (2 probes kettle and a solar collector sensor). It has an outputVoltage 230V - max 120 W for managing solar circulator and a voltage output230 V - max 10 W for managing motorized diverter valve.

3024173

DIGITAL THERMOSTATDevice equipped with a probe input and an output for the implementation of a loadthe high voltage to 250 V as a diverter valve in 2 or 3 wires. The three-digit displayIt allows the display of the temperature and the setting of parametersoperation. Supplied with a cylindrical probe of 6 mm diameter with Ptc10001.5 meter cable. Dimensions: 79 x 115 x 42 mm.

800232

Electrical solar kit - natural circulationFlanged resistance kit for natural circulation systems from 1.5 kW single-phase andpower supply of 220 V. Includes flange, magnesium anode, termostasto and cap.

107069

Security group R1/2ZAssembly product including safety valve, automatic air vent valve andgauge.

12053830

EXTENSION PUMP PRO 25-145 3024259

PIPES KIT EXTENSION PUMP PRO 25 3024260

Page 23: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

36 /

Hydraulics devices and accessories Code

Heating return sensor S4 3024175

Thermostatic mixerMixing valve brass designed for solar application able to provide constant temperature in a wide range of adjustment with reaction times at extremely low thermal transient.Equipped with anti-scald mechanism, protection against calcification and corrosion. Dimensions: 115 x 74 mm.

3024085

Motorized diverter valveDiverter valve for health management integration.230 V power Fluid temperature + 1 ° C / + 95 ° C, maximum differential pressure of 4 bar operation.Threaded male 3/4 “.Dimensions: 94 x 130 x 68 mm.

3087085

Motorized three-way valve for easyDescription: motorized diverter valve vie for exclusive use with Form kettle Macc. Suitable for use with technical water and sanitary water.cabling included

3024076

Motorized diverter valve GAL EVODiverter valve with spring return for installation on the primary circuitKairos system Combi

3024177

FWSForm instantaneous hot water. Flow Activation 2.5 l / min.Maximum flow health 32 l / min. Set of adjustable temperature between 36 and 65 ° C.Dimensions 700 x 400 x 295 mmNB: system interface SENSYS be ordered separately.

3024152

Recirculation kit FWS 3024161

Recirculation kit COMBI 3024174

Solar Accessories

Page 24: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 37

Hydraulics devices and accessories Code

EXPANSION TANKS SOLARExpansion sola vesselr / healthcare 16 lt for MaccSolar expansion vessel 18 ltSolar expansion vessel 25 ltSolar expansion vessel 35 ltSolar expansion vessel 50 ltSolar expansion vessel 80 ltSolar expansion vessel 150 ltSolar expansion vessel 200 lt

30241833024318302431930243203024321302432230243233024324

Generic solar plate heat exchanger 16kWGeneric solar plate heat exchanger 32kWGeneric solar plate heat exchanger 48kWHeat exchanger steel plate brazed, suitable for usewith hot water and heating.5 bar operating pressure, maximum operating temperature 60/45 ° Crespectively with exchange surfaces(m2) * / number plates / volumetric flow permissible(l / h) of 0.4 / 18/720; 0.8 / 34/1440; 1.2 / 48/2500

302403630240373024038

Solar heat exchanger for swimming pools 20kWSolar heat exchanger for swimming pools 40kWSolar heat exchanger for swimming pools 70kW* Shell and tube heat exchanger in titanium,suitable for heating swimming pool water.Operating pressure 2 bar. operating ranges(m3) primary / secondary respectively of 0.9 / 10; 1.7 / 15; 3/20.

302403930240403024041

Adaptation kit hydraulic manifold sideIt contains hydraulic fitting elements for smooth copper pipefrom 16 to 18 and 22 mm and for connection with flat 3/4 “.

3024070

Adaptation kit hydraulic pump unit sideIt contains hydraulic fitting elements for smooth copper pipefrom 16 to 18 and 22 mm and for connection with flat 3/4 “.

3024071

Steel roof passage pipesIt contains two flexible stainless steel tubes from 22 mm insulated 1m long.Connections for smooth copper pipe from 16 to 18 and 22 mm.

3087014

Pre-insulated pipes twinsKit containing 10 m of corrugated stainless steel tube twin 16 mmin diameter and insulated. Collector sensor cable is built.A kit of brass fitting for connectioncollectors and the pumping station.

3024069

Safety hydraulic group 3/4 “ 877085

Siphon 1” 877086

Page 25: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

38 /

Tools for filling and maintenance of the solar system Code

Pure antifreeze liquid (5 lt)Propylene glycol non-toxic, odorless and hygroscopic. Corrosion inhibitorscontained in the propylene glycol protect the metals normally used insolar installations. Miscible with water in all proportions between 25% and 75%.

800215

Manual charge pump antifreezePiston pumps brass for connection to the solar plant during the phasefilling and pressurizing.

800235

GROUP OF FILLING THE SOLAR POWEREDFilling of the solar powered device that reducesup to 80% faster start-up of the system. Compact and transportablean indispensable tool for those who frequently install solar systems.Prevalence 40 m, tank capacity 20 liters. Dimensions 390 x 430 x 600 mm

3024091

Mounting template THERMO HF 150-1 and 200-1 on the ground 3024194

Mounting template THERMO HF 300-2 ground 3024195

Carrying handles kettles THERMO HF 3024198

SOLAR CASECase containing all the tools specific to the pre-installation inspection,the first startup of the solar system and its maintenanceordinary and extraordinary.The case is composed of:• A digital pH meter complete with screwdriver and solution (pH 7 @ 25 °C) forcalibration• A refractometer full manual screwdriver, plastic dropper and cloth for cleaningof the prism• A digital thermometer with 2 probe Tc-K• Two temperature probes Tc-K Clamp• A pressure gauge 0 .. 4.5 bar• A clinobussola• A pack of maps for the measurement of pH

3024090

Solar Accessories

Page 26: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 39

CYLINDERS

Page 27: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

40 /

10

2

4

9

1

7

8

3

15

G

F

B

ED

C

A

13

12

11 L

K

J

14

45°

10

2

4

9

1

7

8

3

15

G

F

B

ED

C

A

13

12

11 L

K

J

14

45°

1. Domestic hot water outlet 1”M2. Domestic cold water inlert 1” F3. Coil return 1”F4. Coil outlet flow 1”F7. Side flange ø110 mm8. Connection for heating element 1” 1/29. Upper magnesium anode10. Upper probe sheath11. Side magnesium anode12. Side probe sheath13. Side access door14. Upper access door15. Recirculation

For the whole accessory list see page 48

BC1S

200 / 300 / 450

• Boiler protection with exclusive titanium-based enamel treatment at 850˚C

• Single-coil, folded-down for uni-form heating of tank

• Equipped for recirculation

• Upper flange with integrated anode and sensor sheath

• 110 mm front inspection flange

• Magnesium anode

• Adjustable support feet

• 3 kw electrical kit (for 200 and 300 litre models) or 1,5 kw availa-ble on request

• Ring nut for electrical kit insertion

Capacity l 200 295 434

Coil exchange surface m2 1 1,3 1,6

Max absorbed power kW 31 36 43

Warming time min 28 36 46

DHW Production

ΔT=30°C l/h 762 885 1057

ΔT=45°C l/h 592 688 822

Pressure loss trought coil mbar 9,0 10,4 13,0

Max working pressure bar 10 10 10

Heat dispersion kWh/24h 1,74 2,11 2,79

Cooling costant wh/l k j 0,18 0,14 0,13

Max working temperature °C 90 90 90

Net weight kg 101 135 151

OVERALL DIMENSIONS

A mm 600 600 714

B mm 1312 1834 1744

C mm 1272 1794 1704

D mm 248 248 270

E mm 434 663 646

F mm 338 338 360

G mm - - 1003

J mm 500 500 630

K mm 324 324 354

L mm 730 959 964

TECHNICAL DATA BC1S 200 BC1S 300 BC1S 450

Floor-standing indirect cylinder with coil

CODE 3060440 3060441 3060442

Page 28: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 41

For the whole accessory list see page 48

6

7

1

10

9

8

2

4

5

3

15

G

C

E

B

D

F

A

13

12

11 L

K

J

14

45°

6

7

1

10

9

8

2

4

5

3

15

G

C

E

B

D

F

A

13

12

11 L

K

J

14

45°

1. Domestic hot water outlet 1”M2. Domestic cold water inlert 1” F3. Lower Coil return 1”F4. Lower Coil outlet flow 1”F5. Upper coil return 1”F6. Upper coil outlet flow 1”F7. Side flange ø110 mm8. Connection for heating element 1” 1/2 “(not for 200 l)”9. Upper magnesium anode10. Upper probe sheath11. Side Magnesium Anode12. Side probe sheath13. Side access door14. Upper access door15. Recirculation

BC2S

200 / 300 / 450

• Boiler protection with exclusive titanium-based enamel treatment at 850˚C

• Double coil with high surface to couple with fossil or renewable energies

• Equipped for recirculation

• Upper flange with integrated anode and sensor sheath

• 110 mm front inspection flange

• Magnesium anode

• Adjustable support feet

• 3 kw electrical integration kit (for 200 and 300 litre models) or 6 kw available on request

• Ring nut for electrical kit insertion (for 300 and 450 litre model)

TECHNICAL DATA BC2S 200 BC2S 300 BC2S 450

Capacity l 200 295 434

Coil Upper Lower Upper Lower Upper Lower

Coil exchange surface m² 0,8 1 0,8 1,3 1 1,6

Max absorbed power kW 27,3 31,0 27,3 36,0 30,8 43,0

DHW Production

ΔT=30°C l/h 671 762 671 885 757 1057

ΔT=45°C l/h 497 667 497 688 589 925

Pressure loss trought coil mbar 1,0 9 1,3 10,4 1,6 13,0

Max working pressure bar 10 10 10

Heat dispersion kWh/24h 1,74 2,11 2,79

Cooling costant wh/l k j 0,18 0,13 0,1

Max working temperature °C 90 90 90

Net weight kg 101 135 151

OVERALL DIMENSIONS

A mm 600 600 714

B mm 1312 1834 1744

C mm 1272 1794 1704

D mm 248 248 270

E mm 434 663 646

F mm 338 338 360

G mm 595 998 1003

H mm 770 1167 1089

I mm 270 270 282

J mm 500 500 630

K mm 324 324 354

L mm 730 959 964

Floor-standing indirect cylinder with double coil

CODE 3060448 3060449 3060450

Page 29: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

42 /

AB

CD

E

F

G

I

J

K

L

M

O

P

N

1

2

4

3

4

4

5

6

6

6

7

8

8

H

9

AB

CD

E

F

G

I

J

K

L

M

O

P

N

1

2

4

3

4

4

5

6

6

6

7

8

8

H

9

800-1000-1500 2000-2500-30001. Cold water inlet G2” F G2” F2. Hot water outlet G 2”F G 2”F3. Recirculation G 1” F G 1 ½ ” F4. Sanitary circuit return G 2”F G 2”F5. Draining fitting connection G 1 ¼ ”F G 1 ¼ ”F6. Well G ½ ”F G ½ ”F7. Flange ø 400 ø 4008. Magnesium anode G 1 ¼ ” F G 1 ¼ ” F9. Upper fitting connection G 1 ¼ ”F G 1 ¼ ”F

MAXIS CDZ

800 / 1000 / 1500 / 2000 / 2500 / 3000

• Steel boiler with exclusive titanium-based enamel treatment

• Magnesium anti-corrosion anode

• Recirculation

• Inspection flange

• Integrated probe-housing sheath

• Flexible removable insulation

• Active anode available as accessory

• 400 mm inspection flange

• Available heating element up to 15 kW

Capacity l 764 884 1493 2015 2436 2857

Max. working pressure bar 7 7 7 7 7 7

Max. cylinder working pressure °C 95 95 95 95 95 95

Cylinder’s thermal dispersions kWh/24h 4,59 4,96 6,51 7,75 8,56 9,30

Mempty mass kg 216 237 360 417 550 617

OVERALL DIMENSIONS

A mm 420 420 490 570 540 540

B mm 520 520 590 670 640 640

C mm 965 1160 1140 1125 1220 1370

D mm 1065 1260 1240 1225 1320 1470

E mm 1460 1710 1780 1610 1870 2220

F mm 1560 1910 1880 1710 1970 2320

G mm 800 830 905 975 960 960

H mm 1265 1050 1065 1125 1150 1150

I mm 1600 1650 1550 1800 2150

J mm 1945 2195 2335 2245 2465 2815

K mm 295 295 365 435 400 400

L mm 835 835 945 1025 1105 1105

M mm 1665 1915 1985 1820 2080 2430

N mm 790 790 1000 1200 1250 1250

O mm 990 990 1200 1400 1450 1450

P mm 1010 1010 1220 1420 1470 1470

TECHNICAL DATA MAXIS CDZ 800

MAXISCDZ 1000

MAXISCDZ 1500

MAXISCDZ 2000

MAXISCDZ 2500

MAXISCDZ 3000

Floor-standing vertical cylinder with high capacity forthe storage of domestic hot water

For the whole accessory list see page 48

CODE 3060464 3060465 3060466 3060467 3060468 3060469

Page 30: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 43

800 / 1000

AB

CDE

FG

H

I

LJ

K

O P

Q

1

2

10

63

11

8

4

9

5

7

12

6

AB

CDE

FG

H

I

LJ

K

O P

Q

1

2

10

63

11

8

4

9

5

7

12

6

Capacity l 721 860Max. working pressure(EN 12897-2006)

bar 7 7

Max. working cylinder temperature °C 95 95Solar coil surface m2 2,5 3,0Solar coil capacity l 14,2 18Max. working coil temperature °C 110 110Coil power at 900 l/h(according to EN12897/EN15332)

kW 23,8 / 22 30,9 / 39,5

Coil load losses at 900 l/h mbar 21 33Max. coil working pressure bar 10 10Cylinder’s thermal dispersions kWh/24h 5,71 6,05Empty mass kg 201 272

OVERALL DIMENSIONS

A mm 295 295B mm 460 440C mm 660 730D mm 760 830E mm 910 1030F mm 1560 1810G mm 1665 1915H mm 475 495I mm 1000 1135J mm 1540 1790K mm 1945 2195L mm 1360 1685M mm - -N mm - -O mm 790 790P mm 990 990Q mm 1005 1005

1. Cold water inlet G2” F2. Hot water outlet G 2”F3. Recirculation G 1” F4. Sanitary circuit return G 1 ½ “ F5. Draining fitting connection G 1 ¼ ”F6. Well G ½” F7. Flange ø 1108. Magnesium anode G 1 ¼ ” F9. Thermometer10. Primary ciurcuit flow G 1 ½ “ F11. Primary ciurcuit return G 1 ½ “ F12. Upper fitting connection G 1 ½ “ F

MAXIS CD1 F

• Steel boiler with exclusive titanium-based enamel treatment

• Magnesium anti-corrosion anode

• Recirculation

• Inspection flange

• Two integrated probe-housing sheaths

• Available heating element kit

• Integrated thermometer

• Pre-assembled flexible removable insulation

• Active anode available as accessory

• Available heating element up to 6 kW

TECHNICAL DATA MAXIS CD1 800F MAXIS CD1 1000F

Floor-standing vertical single-coil cylinder for theproduction of domestic hot water. Integrable with forcedcirculation solar system or high power heating system

For the whole accessory list see page 48

CODE 3060485 3060486

Page 31: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

44 /

AB

CDE

FG

H

I

J

K

L

N

MO P

Q

1

2

8

8

8

4

5

12

9

7

1

11

10

6

6

AB

CDE

FG

H

I

J

K

L

N

MO P

Q

1

2

8

8

8

4

5

12

9

7

1

11

10

6

6

1. Cold water inlet G2” F2. Hot water outlet G 2”F3. Recirculation G 1 ½ ” F4. Heating element G 1 ½ “ F5. Draining fitting connection G 1 ¼ ”F6. Well G ½” F7. Flange ø 4008. Magnesium anode G 1 ¼ ” F9. Thermometer10. Primary ciurcuit flow G 1 ½ “ F11. Primary ciurcuit return G 1 ½ “ F12. Upper fitting connection G 1 ¼ “ F

MAXIS CD1

• Steel boiler with exclusive titanium-based enamel treatment

• Magnesium anti-corrosion anode

• Recirculation

• Inspection flange

• Integrated probe-housing sheath

• Available heating element kit

• Integrated thermometer

• Flexible removable insulation

• Active anode available as accessory

• 400 mm inspection flange

• Available heating element up to 15 kw on the lateral flange, and up to 6 kW on the cap connection

TECHNICAL DATA MAXISCD1 800

MAXISCD1 1000

MAXISCD1 1500

MAXISCD1 2000

MAXISCD1 2500

Capacity l 721 860 1458 1896 2399Max. working pressure(EN 12897-2006)

bar 7 7 7 7 7

Max. working cylinder temperature °C 95 95 95 95 95Solar coil surface m2 2,5 3 4,5 5,4 6Solar coil capacity l 14,2 18 26,6 32,6 36,6Max. working coil temperature °C 110 110 110 110 110Coil power at 900 l/h(according to EN12897/EN15332)

kW 22/23,8 30,9/39,5 30,9 / 39,5 39,9 / 57,5 46,1 / 65,3

Coil load losses at 900 l/h mbar 21 33 33 44 48Max. coil working pressure bar 10 10 10 10 10Cylinder’s thermal dispersions kWh/24h 5,55 5,91 7,45 8,25 9,04Empty mass kg 246 272 420 487 630

OVERALL DIMENSIONSA mm 295 295 365 435 400B mm 415 425 495 560 555C mm 795 865 980 1060 1065D mm 895 965 1080 1160 1165E mm 1195 1315 1435 1460 1535F mm 1560 1810 1880 1710 1970G mm 1665 1915 1985 1820 2080H mm 800 830 905 975 960I mm 1260 1395 1505 1525 1660J mm 1540 1790 1875 1695 1955K mm 1945 2195 2335 2245 2465L mm 900 930 1005 1075 1060M mm a a 1590N mm 1500 1765 1750 1650 1920O mm 790 790 1000 1200 1250P mm 990 990 1200 1400 1450Q mm 1010 1010 1220 1420 1470

Floor-standing vertical single-coil cylinder for theproduction of domestic hot water. Integrable with forced circulation solar system or high power heating system

800 / 1000 / 1000 / 1500 / 2000 / 2500

For the whole accessory list see page 48

CODE 3060475 3060476 3060477 3060478 3060479

Page 32: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 45

AB

CDEFGH

IJ

K

LM

O

Q

N

R S P

T

1

11

6

10

13

3

126

2

14

5

7

4

6

9

8

8

6

AB

CDEFGH

IJ

K

LM

O

Q

N

R S P

T

1

11

6

10

13

3

126

2

14

5

7

4

6

9

8

8

6

TECHNICAL DATA MAXISCD2 800F

MAXISCD2 1000F

MAXISCD2 1500F

MAXISCD2 2000F

MAXISCD2 2500F

Capacity l 706 846 1441 1883 2378Max. working pressure (EN 12897-2006) bar 7 7 7 7 7

Max. working cylinder temperature °C 95 95 95 95 95Solar coil surface m2 2,4 2,5 4,2 4,5 6,0Solar coil capacity l 14,2 14,5 24,6 27,1 36,6Solar coil power at 900 l/h* kW 24,6 / 45,3 30,1 / 62,1 37,2 / 70,9 39,9 / 57,5 51,2 / 72,4Coil load losses at 900 l/h mbar 23 23 67 45 50Max. working coil pressure bar 10 10 10 10 10Solar coil surface m2 2,4 2,5 2,5 3 3,5Upper coil capacity l 14,2 14,5 14,5 18,1 21,2Upper coil power at 900 l/h kW 18 / 23,5 34,7 / 60,3 34,7 / 60,3 35,2 / 65,2 36 / 70,1Upper coil load losses at 900 l/h mbar 15 22 22 23 28Max. working coil pressure bar 10 10 10 10 10Max. working coil temperature °C 110 110 110 110 110Cylinder’s thermal dispersions kWh/24h 4,44 4,91 6,61 7,03 8,17Empty mass kg 236 257 410 477 635* (according to EN 12897/EN15332)

OVERALL DIMENSIONSA mm 295 295 365 435 400B mm 460 460 520 560 555C mm 760 760 995 925 1030D mm 910 910 1230 1110 1270E mm 1050 1115 1380 1265 1475F mm 1290 1360 1555 1415 1645G mm 1350 1465 1650 1520 1755H mm 1500 1565 1785 1645 1895I mm 1560 1810 1880 1710 1970J mm 1665 1915 1985 1820 2080K mm 475 475 570 690 645L mm 1165 1325M mm 980 1015 1305 1215 1405N mm 1250 1215 1415 1450O mm 1560 1685 1865 1700 1955P mm 1540 1790 1875 1700 1955Q mm 1945 2195 2335 2245 2465R mm 790 790 1000 1200 1250S mm 990 990 1200 1400 1450T mm 1005 1005 1215 1415 1465

MAXIS CD2 F

• Steel boiler with exclusive titanium-based enamel treatment

• Magnesium anti-corrosion anode

• Recirculation

• Inspection flange

• Integrated probe-housing sheath

• Available heating element kit

• Integrated thermometer

• Flexible removable insulation

• Large solar surface exchanger and integration for the maximum efficiency

• Coil and back sanitary connections for easy installation

• Available 6 kW heating element

800 - 1000 - 1500 2000 - 25001. Cold water inlet G2” F G2” F2. Hot water outlet G 2”F G 2”F3. Recirculation G 1” F G 1 ½ ” F4. Heating element G 1 ½ “ F G 1 ½ “ F5. Draining fitting connection G 1 ¼ ”F G 1 ¼ ”F6. Well G ½ ”F G ½ ”F7. Flange ø 110 ø 1108. Magnesium anode G 1 ¼ ” F G 1 ¼ ” F9. Thermometer 10. Lower coil flow G 1 ½ “ F G 1 ½ “ F11. Lower coil return G 1 ½ “ F G 1 ½ “ F12. Upper coil flow G 1 ½ “ F G 1 ½ “ F13. Upper coil return G 1 ½ “ F G 1 ½ “ F14. Upper fitting connection G 1 ¼ ”F G 1 ¼ ”F

Floor-standing vertical double-coil cylinder for theproduction of domestic hot water. Integrable with forced circulation solar system or high power heating system

800 / 1000 / 1500 / 2000 / 2500

For the whole accessory list see page 48

CODE 3060487 3060488 3060489 3060490 3060491

Page 33: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

46 /

10

9

8

76

5

43

AB

CDEFG

HIL

MN

o

P

Q

R

1

213

14

15

1211

10

9

8

76

5

43

AB

CDEFG

HIL

MN

o

P

Q

R

1

213

14

15

1211

1. Air valve G 1” F2. Boiler flow G 1”F3. Well G ½” F4. Heating flow G 1”F5. Heating element G 1 ½ “ F6. Well G ½” F7. Return boiler G 1”F8. Well G ½” F9. Heating return G 1”F10. M6 bolt for connection of digital solar pump group11. Solar flow G ¾” F12. Solar return G ¾” F13. DHW production module return G ¾” F14. M8 bolt for connection of DHW production group15. DHW production module flow G ¾” F

MAXIS CK1

BUFFER CYLINDER FOR PRIMARY CIRCUIT WATER WITH COIL 400 / 600 / 800 / 1000

• Black steel cylinder

• Parallel connections for the solar coil, arrangement for easy con-nection to the digital solar pump group-internal pipes and arrange-ment for easy installation on dhw module

• Possibility of integration with elec-trical resistance and connession for air release system

• Designed for integration with Fresh Water Station and Solar Pump Group

TECHNICAL DATA MAXISCK1 400

MAXISCK1 800

MAXISCK1 600

MAXISCK1 1000

Capacity l 374 559 724 830

Max. working pressure bar 3 3 3 3

Max. working cylinder temperature °C 95 95 95 95

Solar coil surface m2 1,5 2,1 2,8 3,4

Solar coil capacity l 9,3 13 17,5 21

Max. working coil temperature °C 110 110 110 110

Coil power at 900 l/h kW 24/ 16,2 28,4/ 50,7 28,6/ 24,8 32,4/ 57,7

(according to EN12897/EN15332)

Coil load losses at 900 l/h mbar 21 25 32 32

Max. working coil pressure bar 10 10 10 10

Cylinder’s thermal dispersions kWh/24h 1,75 2,20 2,51 2,71

Empty mass kg 92 113 155 176

OVERALL DIMENSIONS

A mm 235 230 260 260

B mm 415 405 500 500

C mm 630 760 775 900

D mm 700 815 855 980

E mm 785 900 950 1075

F mm 880 1000 1060 1185

G mm 1060 1400 1315 1550

H mm 1150 1550 1405 1640

I mm 1240 1645 1495 1730

L mm 1550 1865 1725 1975

M mm 380 380 380 380

N mm 1180 1180 1180 1180

O mm 180 180 180 180

P mm 1630 1945 1805 2055

Q mm 800 850 990 990

R mm 600 650 790 790

Buffer cylinder for primary circuit water with coil

For the whole accessory list see page 48

CODE 3060460 3060461 3060462 3060463

Page 34: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 47

A

B

C

D

E

G

F

1

1

1

1

1

1

1

1

3

3

3

3

2

A

B

C

D

E

G

F

1

1

1

1

1

1

1

1

3

3

3

3

2

1. Primary ciurcuit connection G 2” F2. Air release valve G 2” F3. Probe well G ½ “

MAXIS CKZ

BUFFER CYLINDER FOR PRIMARY CIRCUIT WATER, WITHOUT COIL 1500 / 2000 / 2500 / 3000

• Black steel cylinder

• 82” connections to manage high power and high capacity sources

• Ideal to match with plate heat exchangers to storage primary cir-cuit water from solar and other sources

• Direct connection with the boiler thanks to 6 bar working pressure

• 8 probe holders (4 immersed and 4 contact probe holders)

TECHNICAL DATA MAXISCKZ 1500

MAXISCKZ 2000

MAXISCKZ 2500

MAXISCKZ 3000

Capacity l 1473 1971 2363 2667

Max. working pressure bar 6 6 6 6

Max. working cylinder temperature °C 95 95 95 95

Cylinder’s thermal dispersions kWh/24h 6,52 7,77 8,21 8,75

Empty mass kg 224 256 297 324

OVERALL DIMENSIONS

A mm 372 335 390 390

B mm 817 885 860 950

C mm 1342 1441 1365 1510

D mm 1750 1990 1820 2070

E mm 2150 2408 2265 2515

F mm 1000 1100 1250 1250

G mm 1200 1300 1450 1450

Buffer cylinder for primary circuit water, without coil

For the whole accessory list see page 48

CODE 3060456 3060457 3060458 3060459

Page 35: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

48 /

Electrical kits CodeBC1SBC2S

CDZCD1FCD1

CD2FCK1

Electrical kit 3 kWIncludes: heating element, flange 110 mm, wiring and rod thermostat 935118

•(only for 200

and 300 liters)

Electrical kit three-phase 6 kWIncludes: heating element, flange 110 mm, wiring and bubl thermostat mono and three-phase

935119 •

Electrical kit 1,5 kWIncludes: 1” 1/2 screw-on heating element and thermostat.EPR: IP 21 for installation on single-phase side flange

935393 •(no BC2S 200)

•(only 800

1000)•

Electrical kit 2,5 kWIncludes: 1” 1/2 screw-on heating element and thermostat.EPR: IP 21 for installation on single-phase side flange

935394 •(no BC2S 200)

• •

Electrical kit 6 kWIncludes: 1” 1/2 screw-on heating element and thermostat.EPR: IP 21 for installation on three-phase side flange

3078066 • •

Electrical kit 9 kWIncludes heating element on 400 mm flange and thermostat. 3078058 • •

(only CD1)

Electrical kit 15 kWIncludes heating element on 400 mm flange and thermostat. 3078059 • •

(only CD1)

Small active anode Kit 3078061•

(8001000)

Medium active anode Kit 3078062 •(1500)

•(800)

Large active anode Kit 3078063 •(2000)

•(10001500)

Extra Large active anode Kit 3078064•

(25003000)

•(20002500)

Safety group

Hydraulic safety group 1” 885516 •

Hydraulic safety group R1/2Z 12053830 •

Cylinder Accessories

Page 36: FLAT SOLAR COLLECTOR KAIROS XP 2.5-1V / 2.5-1Hfastsolutions.ae/uploads/products/PDF/Ariston_Forced... · 2017. 1. 12. · KAIROS XP 2.5-1V / 2.5-1H TECHNICAL DATA KAIROS XP 2.5-1V

/ 49

HAIL-PROOFHail-resistant thick glass

MADE IN ITALYMade in Italy

SOLAR KEYMARKCompliant with European qualitycertification for solar systems

ENERGY EFFICIENTBetter exploitation of energy and renewable sources, enhanced performance

PERFORMANCE PLUSEnhanced performance thanks to the high quality materialselection to increase heat absorption and limit heat dispersion

SYSTEM MANAGEMENTManage all Ariston products connected in system thanks to BusBridgeNet® technology

MADE IN EUROPEMade in Europe

SOLAR INTEGRATIONIt can be connected in system with Aristonsolar-sourced products

EASY INSPECTIONLarge inspection flange for an easier access to the internal components of the products

HOW TO READ THE SYMBOLS

The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning,to quickly and easily identify performance levels, understand the different ranges and evaluate purchasing criteria.In short, users can familiarise themselves with each machine without becoming confused or wasting time, in line with the Ariston philosophy of always offering the customer - and the professional technician - a service which is clear and easy to use.