4
Revision #12 May 2016 Billy Wolf Page 1 of 4 Berkeley Street Theatre Downstairs Specifications: Contact Information: 26 Berkeley Street, Toronto, Ontario, Canada M5A 2W3 Admin Office: 416-367-8243 Box Office: 416-368-3110 Fax: 416-367-1768 Seating Capacity: Total: 244 Orchestra level: 197 Balcony level: 47 The Downstairs Theatre is wheelchair accessible* Seating is lower House Right. Occupancy restrictions: In accordance with the Office of the Fire Marshall, the maximum allowable persons in the ‘main floor’ area, including production company personnel (cast and crew) is 224 . The maximum allowable for the ‘2 nd level’ area is 60 . Dressing Rooms: 2 - available Capacity of 4-5 persons per dressing room Green Room available Shared area with the Upstairs Theatre Unions: Stage: I.A.T.S.E. Local 58 see overview and agreement *All technical positions must be IA 58 crew non-departmental. Stage Dimensions: (See Floor Plan/Section for specifications) Stage Floor: ¼” Hardboard on ½” tentest and then 2 sheets ¾” plywood sub-floor. Entrances: Audience Entrance: Back Lobby Performance Entrance: SL Fire Exits: SR leading to Front Lobby (Box Office) Main Auditorium - Entrance at rear of theatre StageLeft Through Backstage area out to Berkeley St. Loading Doors: Berkeley Street (south of Front St.) Dimensions: 10’ wide by 12’ high (Approx.) Safety requirements: Steel-toe shoes and long pants must be worn by all persons present in the theatre during load-in/ set-up/ technical work calls/ scenic painting/ painting. Hard Hats are required by all persons present in the theatre up to and including the Lighting Focus call. The use of Personal Protective Equipment (PPE), where applicable, shall be enforced. PPE is the responsibility of the Renter and/or their worker(s) Fire Regulations: Exit signs must be illuminated and visible to all members of the general public at all times. Fire Pull stations must be unobstructed and visible, or their location clearly indicated via signage and accessible to the stage crew, cast, and general public at all times. An unobstructed path to all Emergency exits must be maintained at all times. A clear path must be maintained between the first row of the audience and the stage. No scenery or equipment shall protrude beyond the edge of the stage which would interfere with the front row walkway. Venue: Set Installation: - Scenery may be fastened to the floor via screws or Lag bolts not larger than ¼” diameter. - The walls are brick construction. No scenery shall be attached to the building walls. Renter info: * A site visit is recommended (but not required) to any persons new to this venue * One site visit per group is permitted and one production meeting at least 3 weeks before load in. Electronic and Print versions of the venue ground plan and section drawings are available from the Canadian Stage Assistant PM. The Lighting Designer must supply 2 copies of the Lighting Plot to the Technician. The renting Company must supply all colour gel/ gobos/ expendables such as tape/screws/ black wrap/glue etc The Renting Company shall ensure the Theatre is returned to its neutral state or as outlined in the signed agreement. Parking: There is no Parking available in the Canadian Stage parking lot.

Transcript of Berkeley Street Theatre Downstairs - Canadian Stage … Spec... · Berkeley Street Theatre...

Revision #12 May 2016 Billy Wolf Page 1 of 4

Berkeley Street Theatre Downstairs

Specifications:

Contact Information: 26 Berkeley Street, Toronto, Ontario, Canada M5A 2W3 Admin Office: 416-367-8243

Box Office: 416-368-3110 Fax: 416-367-1768 Seating Capacity: Total: 244

Orchestra level: 197 Balcony level: 47

The Downstairs Theatre is wheelchair accessible* Seating is lower House Right. Occupancy restrictions: In accordance with the Office of the Fire Marshall, the maximum allowable persons in the ‘main

floor’ area, including production company personnel (cast and crew) is 224. The maximum allowable for the ‘2

nd level’ area is 60.

Dressing Rooms: 2 - available Capacity of 4-5 persons per dressing room Green Room available – Shared area with the Upstairs Theatre Unions: Stage: I.A.T.S.E. Local 58 – see overview and agreement *All technical positions must be IA 58 crew non-departmental. Stage Dimensions: (See Floor Plan/Section for specifications) Stage Floor: ¼” Hardboard on ½” tentest and then 2 sheets ¾” plywood sub-floor. Entrances: Audience Entrance: Back Lobby Performance Entrance: SL Fire Exits:

SR – leading to Front Lobby (Box Office) Main Auditorium - Entrance at rear of theatre StageLeft – Through Backstage area out to Berkeley St. Loading Doors: Berkeley Street (south of Front St.)

Dimensions: 10’ wide by 12’ high (Approx.) Safety requirements: Steel-toe shoes and long pants must be worn by all persons present in the theatre during load-in/ set-up/

technical work calls/ scenic painting/ painting. Hard Hats are required by all persons present in the theatre up to and including the Lighting Focus call. The use of Personal Protective Equipment (PPE), where applicable, shall be enforced. PPE is the responsibility of the Renter and/or their worker(s)

Fire Regulations: Exit signs must be illuminated and visible to all members of the general public at all times. Fire Pull stations must be unobstructed and visible, or their location clearly indicated via signage and

accessible to the stage crew, cast, and general public at all times. An unobstructed path to all Emergency exits must be maintained at all times. A clear path must be maintained between the first row of the audience and the stage. No scenery or

equipment shall protrude beyond the edge of the stage which would interfere with the front row walkway. Venue: Set Installation:

- Scenery may be fastened to the floor via screws or Lag bolts not larger than ¼” diameter. - The walls are brick construction. No scenery shall be attached to the building walls.

Renter info: * A site visit is recommended (but not required) to any persons new to this venue * One site visit per group is

permitted and one production meeting at least 3 weeks before load in. Electronic and Print versions of the venue ground plan and section drawings are available from the

Canadian Stage Assistant PM. The Lighting Designer must supply 2 copies of the Lighting Plot to the Technician. The renting Company must supply all colour gel/ gobos/ expendables such as tape/screws/ black wrap/glue

etc The Renting Company shall ensure the Theatre is returned to its neutral state or as outlined in the signed agreement.

Parking: There is no Parking available in the Canadian Stage parking lot.

Revision #12 May 2016 Billy Wolf Page 2 of 4

Lighting

Booth Location:

Centre rear of House (Above the Balcony) Control System:

ETC Express 250 Dimming:

ETC Sensor 144 Dimmers - (1.8kW with one available 6kW) - 3 Dimmers reserved for the House Lights

Luminaries Inventory:

Ellipsoidals

75x – ETC S4 575w Fixtures

S4 lens tubes for S4 Fixtures

25x 36° 44x 26° 10x 50° 6x 19°

2x - ETC S4 575w Zoom Fixtures (25-50° range)

Fresnels 14x 6” 750w 4x Altman 8” 1kw 2x S4 Parnels 575w Cyc Lights 6x Ampro 3-Cell 1k

LX Hanging Limitations/ Restrictions

FOH #3 24 lamp max.

*Note: Luminaires are not permitted in the grid above the catwalks.

Revision #12 May 2016 Billy Wolf Page 3 of 4

Audio

Booth Location:

Centre Rear of House (Above the Balcony) In-House mixing position located at far House Right of balcony (5 seats removed) Playback:

Q-Lab2 on Apple Mac Mini

- Main Mac Mini - Processor: 2 GHz Intel Core 2 Duo - Memory: 4GB 1067 MHz DDR3 - Graphics: NVIDIA GeForce 9400 256 MB - Software: OS X 10.8.5 (12F45)

- Back up Mac Mini - Processor: 2.26 GHZ Intel Core 2 Duo - Memory: 2GB 1067 MHz DDr3 - Graphics: NVIDIA GeForce 9400 256 MB - Software: OS X 10.8.5 (12F45)

M-Audio Profire Lightbridge Firewire to ADAT interface Console

Soundcraft SI Speakers:

Balcony Fills

2x Apogee AE3- Single-Amped 2way, 8Ω, 300 watts continuous, 1200 watts peak

Orchestra Fills @ +9’

2x Apogee AE3- Single-Amped 2way, 8Ω, 300 watts continuous, 1200 watts peak

Centre cluster @ +16’ (suspended from catwalk)

2x Apogee AE5- Bi-Amped, 8Ω LF: 300 W continuous, 1200 W peak HF: 150 W continuous, 600 W peak

SUB

2x JBL 4648- 15" low frequency loud speaker (subs) SL/R (located under the seating)

Other

2x Fostex 6301B- Powered, 4ohms, 10watts Processors and Amps:

1x Apogee P-500 processor (for AE5s) 3x Apogee P3 processor (for AE3s) 2x Bryston 4B- 250w per channel 8Ω (low frequency speakers) (SUBS) 2x QSC mx1500a- 350w per channel 8Ω 2x QSC USA900- 270w per channel 8Ω 1x QSC USA400- 125w per channel 8Ω (centre cluster)

Pre-amp Equip:

2x D.I. Boxes – ART Active X-Direct

Revision #12 May 2016 Billy Wolf Page 4 of 4

Microphones:

1x Shure SM58 (Installed as Voice of God mic in SM Booth) Equalization:

Console EQ Communications:

ClearCom Stations:

5 x Headsets and Belt Packs

Soft Goods

Black Legs

(Quantity x Width x Height)

6 12’-0” 22’-0” 1 6’-7” 14’-6” 1 6’-4” 14’-0” 1 6’-0’ 19’-0” 1 13’-0” 23’-3” 1 6’-4” 21’-6” 1 6’-7” 19’-0” 1 11’-9” 22’-3” 1 1’-0” 27’-10” 1 1’-6” 24’-5” 2 3’-0” 25’-0” 2 4’-0” 29’-0” 1 2’-0” 24’-7” 1 8’-0” 16’-0” (not velour) 1 4’-0” 16’-0” (not velour)

Black Borders

(Quantity x Width x Height)

1 50’-0” 2’-6” 1 45’-0” 5’-8” 1 45’-0” 2’-0” 1 50’-0” 6’-0” (Currently Pinned-up Arched Border) 1 59’-6” 4’-0” 1 56’-0” 9’-0”

Black Drapes

(Quantity x Width x Height)

1 50’-0” 24’-9 ½” (stage width blackout) 1 27’-0’ 22’-5” 1 26’-0” 23’-0” 1 19’-0” 21’-7” 1 16’-0” 22’-4”

Legs - other

(Quantity x Width x Height)

2 8’-4” 13’-10” (BLUE) 1 6’-0” 13’-10” (BLUE)

Cyclorama & Scrims

(Quantity x Width x Height)

1 44’-0” x 24’-0” Fabric cyclorama (*available for an additional fee)