02Y(St)C(St)H 2.6/7 · PDF file · 2010-11-0302Y(St)C(St)H 2.6/7.3AF ... Minimum...

2
hf36e.doc 05.08.2009 page 1 of 2 02Y(St)C(St)H 2.6/7.3AF www.drakact.com I www.draka.com [email protected] Application The radio-frequency cables described in this chapter are used in transmitter and receiver installations in radio communications as well as in the entire field of commercial radio-frequency technology and electronics. Standards DIN 47264, EN50117-1, IEC 61196-1 Flame resistance acc.to. IEC 60332-3-24 Construction Inner conductor copper wire, bare, diameter 2.61 ± 0.02 mm Insulation Foam-PE, diameter 7.3 ± 0.05 outsideConductor Al-PET-Al-foil + copper braid, tinned, 96% optical coverage + Al-PET-Al-foil Sheath FRNC, flame retardant, non corrosive copolymer, diameter 10.3 ± 0.2 Farbe black, RAL 9005 Mechanical properties Minimum bending radius without load 5 x outer diameter with load 10 x outer diameter Temperature during operation -30° C to + 70° C during installation -15° C to + 55° C Corrosivity IEC 60754-2 Electrical properties at 20°C DC resistance Inner conductor 3.2 Ω/l, Outer conductor 3.9 Ω/km Mutual capacitance 80 pF/m Velocity ratio 80 % Characteristic impedance 200 MHz 50 ±2 Transfer impedance 10 MHz ≤ 4 mΩ/m 100 MHz ≤ 2 mΩ/m Operating voltage 1.2 kVrms Test voltage Inner/Outer conductor 3.0 kVrms Screening factor 100-1000 MHz 100 dB Insulation resistance ≥ 10 GΩ*km Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1

Transcript of 02Y(St)C(St)H 2.6/7 · PDF file · 2010-11-0302Y(St)C(St)H 2.6/7.3AF ... Minimum...

hf36e.doc05.08.2009page 1 of 2

02Y(St)C(St)H 2.6/7.3AF

www.drakact.com I www.draka.com [email protected]

ApplicationThe radio-frequency cables described in this chapter are used in transmitter and receiver installations in radio communications as well as inthe entire field of commercial radio-frequency technology and electronics.

StandardsDIN 47264, EN50117-1, IEC 61196-1

Flame resistanceacc.to. IEC 60332-3-24

Construction

Inner conductor copper wire, bare, diameter 2.61 ± 0.02 mm

Insulation Foam-PE, diameter 7.3 ± 0.05

outsideConductor Al-PET-Al-foil + copper braid, tinned, 96% optical coverage + Al-PET-Al-foil

Sheath FRNC, flame retardant, non corrosive copolymer, diameter 10.3 ± 0.2

Farbe black, RAL 9005

Mechanical properties

Minimum bending radius without load 5 x outer diameter

with load 10 x outer diameter

Temperature during operation -30° C to + 70° C

during installation -15° C to + 55° C

Corrosivity IEC 60754-2

Electrical properties at 20°C

DC resistance Inner conductor 3.2 Ω/l,

Outer conductor 3.9 Ω/km

Mutual capacitance 80 pF/m

Velocity ratio 80 %

Characteristic impedance 200 MHz 50 Ω ± 2 Ω

Transfer impedance 10 MHz ≤ 4 mΩ/m

100 MHz ≤ 2 mΩ/m

Operating voltage 1.2 kVrms

Test voltage Inner/Outer conductor 3.0 kVrms

Screening factor 100-1000 MHz 100 dB

Insulation resistance ≥ 10 GΩ*km

Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1

hf36e.doc05.08.2009page 2 of 2

02Y(St)C(St)H 2.6/7.3AF

www.drakact.com I www.draka.com [email protected]

Electrical data at 20°C

Frequency(MHz)

Attenuation(dB/100m)

Max. power rating(Watts)(ambient temperature 40°C andmax. inner conductortemperature 100°C)

Return loss(dB)several peaks are allowed

nominal maximum

1 0.4 17325 Frequency (MHz)

10 1.3 5480 50-450 26

100 4.2 1705 450-1000 23

200 6.0 1205

800 12.3 580

1000 13.7 520

1600 17.8 311

2000 19.9 348

3000 24.9 258

Technical data

Product

code

Designation Type Brand

name

Outer

diameter

Weight Standard

delivery

length

Drum size Gross weight Copper

content

Tensile

force

mm kg/km m *PWD kg N

1002798 02Y(St)C(St)H2.6/7.3

AF-FRNC

2.6/7.3AF

Low loss10.3 166.2 1000

760/360/42

0180 108.6 540

*PWD (Plywood drum)