02Y(St)C(St)H 2.6/7 · PDF file · 2010-11-0302Y(St)C(St)H 2.6/7.3AF ... Minimum...
Transcript of 02Y(St)C(St)H 2.6/7 · PDF file · 2010-11-0302Y(St)C(St)H 2.6/7.3AF ... Minimum...
hf36e.doc05.08.2009page 1 of 2
02Y(St)C(St)H 2.6/7.3AF
www.drakact.com I www.draka.com [email protected]
ApplicationThe radio-frequency cables described in this chapter are used in transmitter and receiver installations in radio communications as well as inthe entire field of commercial radio-frequency technology and electronics.
StandardsDIN 47264, EN50117-1, IEC 61196-1
Flame resistanceacc.to. IEC 60332-3-24
Construction
Inner conductor copper wire, bare, diameter 2.61 ± 0.02 mm
Insulation Foam-PE, diameter 7.3 ± 0.05
outsideConductor Al-PET-Al-foil + copper braid, tinned, 96% optical coverage + Al-PET-Al-foil
Sheath FRNC, flame retardant, non corrosive copolymer, diameter 10.3 ± 0.2
Farbe black, RAL 9005
Mechanical properties
Minimum bending radius without load 5 x outer diameter
with load 10 x outer diameter
Temperature during operation -30° C to + 70° C
during installation -15° C to + 55° C
Corrosivity IEC 60754-2
Electrical properties at 20°C
DC resistance Inner conductor 3.2 Ω/l,
Outer conductor 3.9 Ω/km
Mutual capacitance 80 pF/m
Velocity ratio 80 %
Characteristic impedance 200 MHz 50 Ω ± 2 Ω
Transfer impedance 10 MHz ≤ 4 mΩ/m
100 MHz ≤ 2 mΩ/m
Operating voltage 1.2 kVrms
Test voltage Inner/Outer conductor 3.0 kVrms
Screening factor 100-1000 MHz 100 dB
Insulation resistance ≥ 10 GΩ*km
Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1
hf36e.doc05.08.2009page 2 of 2
02Y(St)C(St)H 2.6/7.3AF
www.drakact.com I www.draka.com [email protected]
Electrical data at 20°C
Frequency(MHz)
Attenuation(dB/100m)
Max. power rating(Watts)(ambient temperature 40°C andmax. inner conductortemperature 100°C)
Return loss(dB)several peaks are allowed
nominal maximum
1 0.4 17325 Frequency (MHz)
10 1.3 5480 50-450 26
100 4.2 1705 450-1000 23
200 6.0 1205
800 12.3 580
1000 13.7 520
1600 17.8 311
2000 19.9 348
3000 24.9 258
Technical data
Product
code
Designation Type Brand
name
Outer
diameter
Weight Standard
delivery
length
Drum size Gross weight Copper
content
Tensile
force
mm kg/km m *PWD kg N
1002798 02Y(St)C(St)H2.6/7.3
AF-FRNC
2.6/7.3AF
Low loss10.3 166.2 1000
760/360/42
0180 108.6 540
*PWD (Plywood drum)