Gray Line NEMA JM/JP Pump Series - Techtop Canada line nema jm-jp... · Power) per NEMA MG 1 part...

Post on 23-Apr-2018

241 views 7 download

Transcript of Gray Line NEMA JM/JP Pump Series - Techtop Canada line nema jm-jp... · Power) per NEMA MG 1 part...

www.techtopcanada.comwww.techtopcanada.com

General Purpose 3Φ

Metric 3Φ

Farm D

uty 1ΦD

efinite Purpose 3ΦA

ccessoriesParts

Reference

Energy VerifiedOnly

C US224693

Operating Parameters• Continuous (S1) duty

• Ambient temperatures up to 40oC

• Installation up to 1000 MASL (3300ft)

Ingress ProtectionThe standard degree of enclosure protection is IP55 (in-

creased IP protection is available). Both drive end and

non-drive end are fitted with double lip oil seals, including

a rubber shaft slinger on the drive end. Conduit box lid is

sealed with a fitted rubber gasket including nipple seals be-

tween conduit box and stator body. DE/NDE endbell fitted

with sintered brass one-way drain.

Insulation and Inverter Rating• Class F Insulation

• Designed to Class B temperature rise

• Vacuum Impregnated

• Inverter Rated 20:1 Variable Torque (1.0 S.F on VFD

Power) per NEMA MG 1 part 31

ConnectionUp to and Including 215JM/JP Frame:

• 9-Lead 230V parallel-wye / 460V series-wye connection

• 3-Lead 575V wye connection

254JM/JP Frame and Larger:

• 12-Lead 230V parallel-delta / 460V delta connection

• 6-Lead 460V or 575V single voltage delta connection

Gray Line NEMA JM/JP Pump Series1 - 50HP, EPAct Rated, Three Phase (TEFC)

Basic Specifications Power Ratings from 1 to 50HP

Three Phase, 2 and 4 Pole, 60Hz (Useable at 50Hz)

230/460V & 575V 60Hz

Totally Enclosed Fan Cooled (TEFC)

Definite Purpose Product OverviewThree phase, enhanced performance closed coupled pump motors. Cast aluminum 215JM/JP and below, cast iron 254JM/JP and above, EPAct rated. Features a multi-mount arrangement incor-porating bolt on feet and flange mount configura-tion. 2 and 4 pole, 1 to 50HP.

Standard Features• Removable feet F1, F2, F0 field convertible

• 1.25 Service Factor with with 60Hz operation

• 24 month warranty

• Conduit Box is 90o rotatable

• CSA Certified for Class I, Division II, Groups A, B, C

and D / Class I, Zone 2, Groups IIC, IIB, IIA

• Anti-microbial (tropicalization) on stator winding

• Regreasable bearings 254JM/JP frame and larger

• Shear stabalized polyurea grease

• 1045 steel shaft

• Surface finish:

• Alkyd enamel RAL7024 - Graphite Gray

• Black oxide surface treatment for increased cor-

rosion resistance (aluminum models only)

• Stainless steel nameplate

• Corrosion resistant hardware

• Ultra high strength, reusable lifting straps included

wth motors 254JM/JP frame and larger

Cast Aluminum: 143JM/JP to 215JM/JPCast Iron: 254JM/JP to 326JM/JP

CC096A

RA

T E D 2 0 : 1 VT

INVERTER

R

A T E D I P 5

5

W

ATER PROOF

JP FramesARRIVING NOVEMBER 2014

Please call for details

www.techtopcanada.comwww.techtopcanada.com

Gen

eral

Pur

pose

Met

ric 3Φ

Farm

Dut

y 1Φ

Def

inite

Pur

pose

Acc

esso

ries

Part

sR

efer

ence

www.techtopcanada.com

HP Model MFG NumberSync.RPM

NEMAFrame

Full Load Current In (A) Full Load Weight(lbs.)

“C” Dim.Inches JM/JP

ListPrice 230V 460V 575V Eff. (%)

1 JMA0004[ ] TFA143T1U4B 1800 143JM or JP 3.16 1.58 1.26 82.5 28.0 15.2/18.3 $367

1.5JMA0012[ ] TFA143T1.5U2B 3600 143JM or JP 4.24 2.12 1.69 82.5 25.0 15.2/18.3 $378

JMA0014[ ] TFA145T1.5U4B 1800 145JM or JP 4.56 2.28 1.82 84.0 34.5 16.2/19.3 $431

2JMA0022[ ] TFA145T2U2B 3600 145JM or JP 5.42 2.71 2.17 84.5 29.5 16.2/19.3 $435

JMA0024[ ] TFA145T2U4B 1800 145JM or JP 5.98 2.99 2.39 84.0 39.5 16.2/19.3 $456

3

JMA0032[ ]S TFA145T3U2B 3600 145JM or JP 7.78 3.89 3.11 85.5 38.0 16.2/19.3 $630

JMA0032[ ] TFA182T3U2B 3600 182JM or JP 7.70 3.85 3.08 85.5 50.0 17.3/20.4 $659

JMA0034[ ] TFA182T3U4B 1800 182JM or JP 8.08 4.04 3.24 87.5 62.0 17.3/20.4 $658

5JMA0052[ ] TFA184T5U2B 3600 184JM or JP 11.8 5.90 4.72 87.5 62.0 18.3/21.4 $719

JMA0054[ ] TFA184T5U4B 1800 184JM or JP 12.6 6.32 5.05 87.5 73.5 18.3/21.4 $742

7.5

JMA0072[ ]S TFA184T7.5U2B 3600 184JM or JP 17.3 8.66 6.93 88.5 76.0 18.3/21.4 $1,026

JMA0072[ ] TFA213T7.5U2B 3600 213JM or JP 17.0 8.50 6.85 88.5 95.0 19.9/23.8 $968

JMA0074[ ] TFA213T7.5U4B 1800 213JM or JP 18.4 9.18 7.35 89.5 113.0 19.9/23.8 $1,032

10JMA0102[ ] TFA215T10U2B 3600 215JM or JP 22.8 11.4 9.15 89.5 115.0 21.4/25.3 $1,081

JMA0104[ ] TFA215T10U4B 1800 215JM or JP 24.4 12.2 9.78 89.5 131.0 21.4/25.3 $1,197

15

JMA0152[ ] TFA215T15U2B 3600 215JM or JP 33.2 16.6 13.3 90.2 135.0 21.4/25.3 $1,744

JMC0152[ ] TFC254T15U2B 3600 254JM or JP 35.2 17.6 14.08 90.2 278.0 25.8/28.17 $1,731

JMC0154[ ] TFC254T15U4B 1800 254JM or JP 37.2 18.6 14.88 91.0 280.0 25.8/28.17 $1,684

20JMC0202[ ] TFC256T20U2B 3600 256JM or JP 46.4 23.2 18.56 90.2 295.0 27.53/29.9 $1,984

JMC0204[ ] TFC256T20U4B 1800 256JM or JP 47.0 23.5 18.80 91.0 315.0 27.53/29.9 $1,914

25

JMC0252[ ]S TFC256T25U2B 3600 256JM or JP 57.8 28.9 23.12 91.0 331.0 27.53/29.9 $2,272

JMC0252[ ] TFC284TS25U2B 3600 284JM or JP 57.8 28.9 23.12 91.0 353.0 28.13/31.0 $2,317

JMC0254[ ] TFC284T25U4B 1800 284JM or JP 59.2 29.6 23.68 92.4 406.0 28.13/31.0 $2,321

30JMC0302[ ] TFC286TS30U2B 3600 286JM or JP 69.0 34.5 27.60 91.0 419.0 29.63/32.5 $2,688

JMC0304[ ] TFC286T30U4B 1800 286JM or JP 71.0 35.5 28.43 92.4 404.0 29.63/32.5 $2,674

40

JMC0402[ ]S TFC286TS40U2B 3600 286JM or JP 93.0 46.5 37.19 91.7 442.0 29.63/32.5 $3,497

JMC0402[ ] TFC324TS40U2B 3600 324JM or JP 93.0 46.5 37.19 91.7 523.0 31.34/32.97 $3,491

JMC0404[ ] TFC324T40U4B 1800 324JM or JP 94.2 47.1 37.69 93.0 584.0 31.34/32.97 $3,485

50JMC0502[ ] TFC326TS50U2B 3600 326JM or JP 117.0 58.5 46.81 92.4 551.0 32.84/34.47 $3,964

JMC0504[ ] TFC326T50U4B 1800 326JM or JP 118.4 59.2 47.35 93.0 606.0 32.84/34.47 $3,959

143JM/JP - 326JM/JP Frame Foot-Mount NEMA JM/JP Gray Line

Gray Line NEMA JM/JP Pump Series1 - 50HP, EPAct Rated, Three Phase (TEFC)

Purchasing Data

Replace ‘JM’ with ‘JP’ for JP type shaft

Replace [ ] with D for 230/460V, or F for 575V

www.techtopcanada.com

General Purpose 3Φ

Metric 3Φ

Farm D

uty 1ΦD

efinite Purpose 3ΦA

ccessoriesParts

Reference

C

2F*2F

BA AHEQ

ET

EMEL ES

T1

T2

BB

AK

BFAB

2EE

D

P O

A

AJ

B

AB

O

D

2EE

A

AJ45°

BF2F

H

B

P

BAETAH

C

SR

d1

EM

T1

AKAA

BB

EQ

EL

U

ES

Gray Line NEMA JM/JP Pump Series1 - 50HP, EPAct Rated, Three Phase (TEFC)

NEMAFrame

Foot Mounting General NEMA C-Flange

E 2E 2F 2F* H BA A B D O P AA AB AJ AK BB BF

143JM/JP2.75 5.5

4.0-- 0.34

*0.5 2.25 7.05.1

3.5 7.0 6.93 1-NPT3/4” 5.5 5.875 4.5 0.16 4*3/8-16UNC

145JM/JP 5.0 6.1

182JM/JP3.75 7.5

4.5-- 0.59

*0.43 2.75 9.05.8

4.5 8.85 8.65 1-NPT3/4” 6.6 7.25 8.5 0.25 4*1/2-13UNC

184JM/JP 5.5 6.8

213JM/JP4.25 8.5

5.5-- 0.59

*0.43 3.5 10.17.1

5.25 10.4 10.3 1-NPT1” 7.3 7.25 8.5 0.25 4*1/2-13UNC

215JM/JP 7.0 8.6

254JM/JP5 10.0 8.25

--0.53 4.25 12.36

10.356.25 12.44 12.36 1-NPT

1-1/4” 10.0 7.25 8.5 0.27 4*1/2-13UNC256JM/JP 10.0 12.05

284JM/JP5.5 11.0 9.5

--0.53 4.75 13.8

12.27.0 13.9 13.78 1-NPT

1-1/2” 10.83 9.0 10.5 0.27 4*5/8-11UNC286JM/JP 11.0 13.7

324JM/JP6.25 12.5 10.5

--0.66 5.25 15.4

13.08.0 15.9 15.71 1-NPT

2” 13.0 11.0 12.5 0.27 4*5/8-11UNC326JM/JP 12.0 14.5

Figure 1 - Cast Aluminum JM/JP Model Figure 2 - Cast Iron JM/JP Model

Dimensions are in inches

Dimensional Drawings

NEMAFrame

Shaft End - Type JM Shaft End - Type JP

Lengths Diameters Keyway Threaded Hole JM Lengths Diameters Keyway Threaded Hole JP

AH EQ ET U EM EL S R ES d1 (UNC) T1 T2 C AH EQ ET U EM EL S R ES d1 (UNC) T1 T2 C

143JM/JP4.25 0.625 2.875 0.874 1.0 1.156 0.187 0.771 1.65 3/8-16 0.75 1.1

15.27.312 1.563 5.937 0.874 1.0 1.156 0.187 0.771 1.65 3/8-16 0.75 1.1

18.3

145JM/JP 16.2 19.3

182JM/JP4.25 0.625 2.875 0.874 1.0 1.25 0.187 0.771 1.65 3/8-16 0.75 1.1

17.37.312 1.563 5.937 0.874 1.0 1.25 0.187 0.771 1.65 3/8-16 0.75 1.1

20.4

184JM/JP 18.3 21.4

213JM/JP4.25 0.625 2.875 0.874 1.0 1.25 0.187 0.771 1.65 3/8-16 0.75 1.1

19.98.125 2.375 5.875 1.249 1.375 1.75 0.252 1.112 2.53 3/8-16 0.75 1.1

23.8

215JM/JP 21.4 25.3

254JM/JP5.25 0.625 3.0 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

25.88.125 2.375 5.875 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

28.17

256JM/JP 27.53 29.9

284JM/JP5.25 0.625 3.0 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

28.138.125 2.375 5.875 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

31.0

286JM/JP 29.63 32.5

324JM/JP5.25 0.625 3.0 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

31.348.125 2.375 5.875 1.249 1.375 1.75 0.252 1.112 2.53 1/2-13 1.0 1.5

32.97

326JM/JP 32.84 34.47

Dimensions are in inches

AB

O

D

2EE

A

AJ45°

BF2F

H

B

P

BAETAH

C

SR

d1

EM

T1

AK

AA

BB

EQ

EL

U

ES

AB

O

D

2EE

A

AJ45°

BF2F

H

B

P

BAETAH

C

SR

d1

EM

T1

AK

AA

BB

EQ

EL

U

ES

www.techtopcanada.comwww.techtopcanada.com

Gen

eral

Pur

pose

Met

ric 3Φ

Farm

Dut

y 1Φ

Def

inite

Pur

pose

Acc

esso

ries

Part

sR

efer

ence

Full Load Data Full Load Current In (A) Bearings

HPSync.Speed

NEMAFrame

RPM(r/min)

Efficiency(%)

PF(Cosθ) 230V 460V 575V

KVACode

Weight(lbs.)

DE NDE“C” Dim.

Inches JM/JP

1 1800 143JM or JP 1730 82.5 0.72 3.16 1.58 1.26 K 28.0 6206ZZ 6205ZZ 15.2/18.3

1.53600 143JM or JP 3490 82.5 0.79 4.24 2.12 1.69 K 25.0 6206ZZ 6205ZZ 15.2/18.3

1800 145JM or JP 1730 84.0 0.72 4.56 2.28 1.82 K 34.5 6206ZZ 6205ZZ 16.2/19.3

23600 145JM or JP 3500 84.5 0.82 5.42 2.71 2.17 L 29.5 6206ZZ 6205ZZ 16.2/19.3

1800 145JM or JP 1730 84.0 0.75 5.98 2.99 2.39 K 39.5 6206ZZ 6205ZZ 16.2/19.3

3

3600 145JM or JP 3490 85.5 0.83 7.78 3.89 3.11 L 50.0 6206ZZ 6205ZZ 16.2/19.3

3600 182JM or JP 3520 85.5 0.84 7.70 3.85 3.08 M 50.0 6207ZZ 6206ZZ 17.3/20.4

1800 182JM or JP 1750 87.5 0.78 8.08 4.04 3.24 L 62.0 6207ZZ 6206ZZ 17.3/20.4

53600 184JM or JP 3510 87.5 0.90 11.8 5.90 4.72 L 62.0 6207ZZ 6206ZZ 18.3/21.4

1800 184JM or JP 1740 87.5 0.84 12.6 6.32 5.05 K 73.5 6207ZZ 6206ZZ 18.3/21.4

7.5

3600 184JM or JP 3500 88.5 0.90 17.3 8.66 6.93 K 95.0 6207ZZ 6206ZZ 18.3/21.4

3600 213JM or JP 3510 88.5 0.91 17.0 8.50 6.85 K 95.0 6308ZZ 6208ZZ 19.9/23.8

1800 213JM or JP 1750 89.5 0.84 18.4 9.18 7.35 K 113.0 6308ZZ 6208ZZ 19.9/23.8

103600 215JM or JP 3520 89.5 0.92 22.8 11.4 9.15 L 115.0 6308ZZ 6208ZZ 21.4/25.3

1800 215JM or JP 1750 89.5 0.86 24.4 12.2 9.78 L 131.0 6308ZZ 6208ZZ 21.4/25.3

15

3600 215JM or JP 3520 90.2 0.92 33.2 16.6 13.3 L 135.0 6308ZZ 6208ZZ 21.4/25.3

3600 254JM or JP 3540 90.2 0.89 35.2 17.6 14.08 G 278.0 6309 C3 25.8/28.17

1800 254JM or JP 1760 91.0 0.83 37.2 18.6 14.88 G 280.0 6309 C3 25.8/28.17

203600 256JM or JP 3530 90.2 0.90 46.4 23.2 18.56 F 295.0 6309 C3 27.53/29.9

1800 256JM or JP 1760 91.0 0.84 47.0 23.5 18.80 G 315.0 6309 C3 27.53/29.9

25

3600 256JM or JP 3550 91.0 0.90 57.8 28.9 23.12 F 353.0 6309 C3 27.53/29.9

3600 284JM or JP 3550 91.0 0.90 57.8 28.9 23.12 F 353.0 6311 C3 28.13/31.0

1800 284JM or JP 1770 92.4 0.86 59.2 29.6 23.68 G 406.0 6311 C3 28.13/31.0

303600 286JM or JP 3550 91.0 0.90 69.0 34.5 27.60 F 419.0 6311 C3 29.63/32.5

1800 286JM or JP 1770 92.4 0.86 71.0 35.5 28.43 F 404.0 6311 C3 29.63/32.5

40

3600 286JM or JP 3560 91.7 0.90 93.0 46.5 37.19 G 523.0 6311 C3 29.63/32.5

3600 324JM or JP 3560 91.7 0.90 93.0 46.5 37.19 G 523.0 6312 C3 31.34/32.97

1800 324JM or JP 1770 93.0 0.87 94.2 47.1 37.69 E 584.0 6312 C3 31.34/32.97

503600 326JM or JP 3560 92.4 0.90 117.0 58.5 46.81 F 551.0 6312 C3 32.84/34.47

1800 326JM or JP 1770 93.0 0.87 118.4 59.2 47.35 E 606.0 6312 C3 32.84/34.47

High Efficiency 60Hz Performance Data