X-EGN, X-GHP, X-GN: GX Fasteners - Hilti - Latvija€¦ · X-EGN, X-GHP, X-GN: GX Fasteners General...
Transcript of X-EGN, X-GHP, X-GN: GX Fasteners - Hilti - Latvija€¦ · X-EGN, X-GHP, X-GN: GX Fasteners General...
03 / 2017 139
X-EGN, X-GHP, X-GN
D
X-EGN, X-GHP, X-GN: GX Fasteners
General information
Material specifications
Carbon steel shank: X-EGN HRC 58 X-GHP HRC 58 X-GN HRC 53.5
Zinc coating: 2–13 μm
Recommended fastening tools
GX 120, GX 120-ME GX 100, GX 100 ESee X-EGN, X-GHP, X-GN fastener program in the next pages and Tools and equipment chapter for more details.
Approvals
ICC-ESR 1752 (USA): X-GN 20/27/32, X-EGN 14, X-GHP 16/18/20/24IBMB X-GHP, X-GNNote: technical data presented in these approvals and design guidelines reflect specific local conditions and may differ from those published in this handbook.
Dimensions
X-EGN 14
Examples
o 6.
8
15.8
14
o 3
1.8
X-GHP 16/18/20/24
o 6.
8
L
o 3
1.8 Ls
X-GN 20/27/32
o 6.
8
o 3
1.9 Ls
L
X-GN 39
o 5
40.9
39
o 2.6
1.9
Product data
Applications
Drywall tracks to concrete and steel
Electrical applications Temporary tacking of compos-ite deck to steel beams
X-EGN, X-GHP, X-GN
140 03 / 2017
D
Recommended loads
Load data
Nrec Vrec
Concrete Nrec [kN] Vrec [kN] hET [mm]
0.4 0.4 ≥ 27
0.3 0.3 ≥ 22
0.2 0.2 ≥ 18
0.1 0.1 ≥ 14
Steel Nrec = Vrec = 0.4 kN
Design conditions:
• Minimum 5 fastenings per fastened unit• All visible failures must be replaced
Conditions:
• The intended use of the fastenings is to secure the deck position and to ensure a safe working platform during the erection state only. The fasteners serve as temporary fixation until the shear connectors of the composite beams are attached.• At each permanent composite deck support, it is recommended to drive at least one fastener per trough.• Every deck panel must be fixed at least with two fasteners at every permanent support.• Single layer sheet with a maximum thickness of 1.25 mm.• Sheeting grade up to S450 acc. to EN 10346.• Minimum base material thickness: 6 mm.• Minimum steel grade: S235 acc. to EN 10025-2.
Recommended loads of X-EGN 14 MX for temporary tacking of composite decks
Tension Nrec [kN] Shear Nrec [kN]
0.4 0.4
03 / 2017 141
X-EGN, X-GHP, X-GN
D
Thickness of base material
Application requirements
70
hmin
dnom
t II
Concrete Steel
Thickness of fastened material
hmin = 60 mm (dnom = 3.0 mm)
tll ≥ 4 mm
Wooden track: tl ≤ 24 mmMetal track: tl ≤ 2 mm
Spacing and edge distances (mm)
8040
40
804080
Spacing along track (as per U.S. Gypsum Handbook)
All track ends (cut-outs for doors),secure with 2 nails
70100160-800
2280
Distance to edge of concrete / sandlime masonry
Fastener spacings on wood:
Corrosion information The intended use only comprises fastenings which are not directly exposed to external weather conditions or moist atmospheres. For further detailed information on corrosion see relevant chapter in Direct Fastening Principles and Technique section.
≥15
≥ 4.5 dnom
X-EGN, X-GHP, X-GN
142 03 / 2017
D
Fastener selection
Fastener selection and system recommendation
Fastening to concrete / sandlime masonry Application Base material
X-GN 39 MX Wooden track (tI ≤ 24 mm) Concrete/sandlime masonry
X-GN 27MX Metal track Concrete/sandlime masonry
X-GN 20 MX Metal track Concrete/sandlime masonry
X-GHP_MX Metal track Concrete/sandlime masonry
Fastening to steel Application Base material
X-EGN 14 Metal track Steel
increasing strength
Steel strength Rm [N/mm2]
Stee
l thi
ckne
ss t I
I [m
m]
360468
1012141618202224
>26
500 600 700450400 550 650 750
S355Jxx
S275Jxx
S235Jxx
Base Material Ultimate Strength [N/mm2]
Bas
e M
ater
ial T
hick
ness
[ mm
]
6
8
10
12
14
16
18
20
22
24
>26
360 380 400 420 440 460 480 500 520 540 560 580 600 620 640
S235S275
S355
Steel For temporary tacking of composite decks
Application limits
X-EGN 14 Design conditions:
• Single layer sheet with a maximum thickness of 1.25 mm.• Sheeting grade up to S450 acc. to EN 10346.• Minimum base material thickness: 6 mm• Minimum steel grade: S235 acc. to EN 10025-2
03 / 2017 143
X-EGN, X-GHP, X-GN
D
Fastening inspection
Fastening quality assurance
hNVStI
hCS
tI
hNVStI
X-GN/GHP: hNVS = 2–5 mm X-GN 39: hCS = 2–3 mm X-EGN 14: hNVS = 4–7 mm
Fastener program
Item no. Ls [mm] L [mm] dnom [mm]
X-EGN 14 MX 340231 14 15.8 3.0
X-GHP 16 MX 2071471 16 17.8 3.0
X-GHP 18 MX 340228 18 19.8 3.0
X-GHP 20 MX 285724 20 21.8 3.0
X-GHP 24 MX 438945 24 25.8 3.0
X-GN 20 MX 340232 19 20.9 3.0
X-GN 27 MX 340230 27 28.9 3.0
X-GN 32 MX 340233 32 33.9 3.0
X-GN 39 MX 340234 39 40.9 2.6
Tool and gas canDesignation
GX 120 / GX 120 ME with gas can GC 20, GC 21 and GC 22
GX 100 / GX 100 E with gas can GC 11 and GC 12 (for USA)
Fastening to concrete / sandlime masonry Fastening to steel
D
144 03 / 2017