TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45...

6
DSP SERIES FOR FIRE PUMP D1S SERIES FOR 2 POLES www.dessunpower.com ECOL MOTOR MODEL D1S 280M-2 TECHNICAL DATA SHEET General Data Electrical Data Frame size 280 Output 90 kW Housing material Casting iron Frequency 50 Hz Install model According to the standard Voltage (±5%) 400 V Δ @ 50Hz Type of feet Removable feet (Standard) Fixed feet (Optional) 690 V Y @ 50Hz Net weight 572 kg 480 V Δ @ 60Hz Insulation class F (Standard) 828 V Y @ 60Hz H (Optional) Rotation speed 2930 RPM @ 50Hz Protection degree IP 55 (Standard) 3516 RPM @ 60Hz IP 56 (Optional) Rated current 155.2 A (In) @ Δ 50Hz Thermal protection Without (Standard) 89.6 A (In) @ Y 50Hz Customizable (Optional) Starting current 7.5 ×In Service duty S1 Rated torque 293.34 Nm (Mn) Vibration level A Starting torque 2 ×Mn Balance Half-key balanced Breakdown torque 2.3 ×Mn Cable glands 2 - M50× 1.5 IE1 Cooling IC 411 Efficiency 93 @ 100% load Painting color RAL 7024 (Standard) 92.8 @ 75% load Customizable (Optional) 90.9 @ 50% load Regulations IEC / DIN / ISO / VDE / EN Power factor cosφ 0.9 @ 100% load Standard IEC 60034 Mechanical Data Environmental conditions Bearings brand C&U (Standard) Ambient temperature From -20°C to +40°C Customizable (Optional) Maximum altitute 1000 m above sea level Bearings type 6319 C3 (DE) 6319 C3 (NDE) Lifetime of bearings - hours Allowed radial load 6750 N Allowed axial load 57700 N Grease type polyurea-based grease Lubrication interval of NDE bearing 3500 h Lubrication interval of DE bearing 3500 h Moment of inertia 0.795390 Kg*m² Noise level 94 dB(A)

Transcript of TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45...

Page 1: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency

DSP SERIES FOR FIRE PUMP

D1S SERIES FOR 2 POLES

www.dessunpower.com

ECOL MOTOR

MODEL D1S 280M-2

TECHNICAL DATA SHEET

General Data Electrical Data

Frame size 280 Output 90 kW

Housing material Casting iron Frequency 50 Hz

Install model According to the standard

Voltage (±5%)

400 V Δ @ 50Hz

Type of feet

Removable feet

(Standard) Fixed feet

(Optional)

690 V Y @ 50Hz

Net weight 572 kg 480 V Δ @ 60Hz

Insulation class F (Standard) 828 V Y @ 60Hz

H (Optional) Rotation speed 2930 RPM @ 50Hz

Protection degree IP 55 (Standard) 3516 RPM @ 60Hz

IP 56 (Optional) Rated current 155.2 A (In) @ Δ 50Hz

Thermal protection Without (Standard) 89.6 A (In) @ Y 50Hz

Customizable (Optional) Starting current 7.5 ×In

Service duty S1 Rated torque 293.34 Nm (Mn)

Vibration level A Starting torque 2 ×Mn

Balance Half-key balanced Breakdown torque 2.3 ×Mn

Cable glands 2 - M50× 1.5 IE1

Cooling IC 411 Efficiency

93 @ 100% load

Painting color RAL 7024 (Standard) 92.8 @ 75% load

Customizable (Optional) 90.9 @ 50% load

Regulations

IEC / DIN / ISO / VDE /

EN Power factor cosφ

0.9 @ 100% load

Standard IEC 60034

Mechanical Data

Environmental conditions Bearings brand C&U (Standard)

Ambient temperature From -20°C to +40°C Customizable (Optional)

Maximum altitute 1000 m above sea level Bearings type 6319 C3 (DE)

6319 C3 (NDE)

Lifetime of bearings - hours

Allowed radial load 6750 N

Allowed axial load 57700 N

Grease type polyurea-based grease

Lubrication interval of NDE bearing 3500 h

Lubrication interval of DE bearing 3500 h

Moment of inertia 0.795390 Kg*m²

Noise level 94 dB(A)

Page 2: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency
Page 3: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency

Pump Performance Curve

0

30

60

90

120Po

wer

- kW Power

0

15

30

45

60

75

90

105

120

135

150

0

10

20

30

40

50

60

70

80

90

100

Hea

d - m

Effic

ienc

y - %

306 mm

Efficiency

Minimum Continuous Safe Flow (MCSF)

0

3

6

0 20 40 60 80 100 120 140 160 180 200 220 240 260

NPS

Hr -

m

Flow - m3/h

NPSHr

Customer :Customer enquiry :Project : DefaultQuote number : 312657 Item number : 001Quantity : 1Date last saved : 09 Oct 2020 11:56 AM

Pump Size/ Stages : CPHM 80/32/ 1Speed, rated : 2970 rpmBased on curve number : HD13723KA0 Rev 0Viscosity : 1.00 cStCq/Ch/Ce/Cn [HI2010] : 1.00 / 1.00 / 1.00 / 1.00Minimum recommended driverrating

: 90.00 kW / 121 hp

Performance testing standard : ISO 9906 / ANSI-HI 14.6 Gr 2B

Flow, rated : 140.0 m3/hDifferential Head : 120.0 mFluid density rated : 0.998 kg/dm3Efficiency : 67.92 %Power, rated : 67.27 kWNPSH required : 3.04 mLiquid Type/ Application : Water

Notes: 1. Performance at shut off condition is approximate. 2. Rated impeller diameter is approximate. 3. Only duty point is guaranteed as per testing standard.

Page 4: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency
Page 5: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency
Page 6: TECHNICAL DATA SHEET · 2021. 3. 15. · Pump Performance Curve 0 30 60 90 120 kW Power 0 15 30 45 60 75 90 105 120 135 150 0 10 20 30 40 50 60 70 80 90 100 m % 306 mm Efficiency