Semi-Rigid Cables - Partner Electronic · PDF fileSemi-Rigid Cables (cont’d) 2098 West...
Transcript of Semi-Rigid Cables - Partner Electronic · PDF fileSemi-Rigid Cables (cont’d) 2098 West...
2098 West Main Street, Stroudsburg, PA 18360Tel: 1-877-MegaPhase / 570-424-8400
Fax: 1-877-MegaFax / 570-424-6031Email: [email protected] / Web: www.megaphase.com
Excellence in RF Interconnects
Electrical Data
Maximum Frequency:SR034, SR047 & SR086: 50 GHzSR141: 34 GHzSR250: 18 GHz
Impedence: 50 Ω nominal
Propagation Velocity: 69% nominal
Time Delay: 1.47 ns/ft (4.82 ns/m)
Shielding Effectiveness:-110 dB minimum (cable only)
Dielectric Withstanding Voltage:SR034 & SR047: 2.0 kV at 60 HzSR086 & SR141: 5.0 kV at 60 HzSR250: 7.5 kV at 60 Hz
Capacitance: 29 pF/ft (95.1 pF/m)
Cable Construction
Inner Conductor:SR034, SR047, SR086 & SR141:
Solid Ag-plated Cu-clad SteelSR250: Solid Ag-plated Cu
Dielectric: PTFE
Outer Conductor: Sn-plated Cu Tube
Mechanical Data
Finished Outer Diameter:SR034: 0.034 in (0.086 cm)SR047: 0.047 in (0.119 cm)SR086: 0.086 in (0.218 cm)SR141: 0.141 in (0.358 cm)SR250: 0.250 in (0.635 cm)
Static Bend Radius:SR034: 0.05 in (0.127 cm)SR047: 0.08 in (0.191 cm)SR086: 0.13 in (0.318 cm)SR141: 0.25 in (0.635 cm)SR250: 0.50 in (1.270 cm)
Weight with Standard Jacket /Armor:SR034: 0.003 lbs/ft (0.004 kg/m)SR047: 0.005 lbs/ft (0.007 kg/m)SR086: 0.016 lbs/ft (0.024 kg/m)SR141: 0.035 lbs/ft (0.052 kg/m)SR250: 0.106 lbs/ft (0.158 kg/m)
Operating Temp. Range:SR034 & SR047: -40 to 212º F (-40 to 100º C)SR086 & SR141: -40 to 257º F (-40 to 125º C)SR250: -40 to 194º F (-40 to 90º C)
Semi-Rigid Cables
Cable Assemblies with Precision CNC Bends
SR series cable is MIL-DTL-17 qualified with a tin-plated copper outer conductor. Other outerconductor platings available upon request. Cable assemblies are typically custom built withintight tolerances and are capable of frequencies up to 50 GHz with precision connectors.Applications include delay lines, switch matrices, test fixtures and instrumentation.
Available Connectors
SR034: MMCX, SMA, SSMA
SR047: 2.4mm, 2.92mm, 3.5mm, SMA
SR086: 2.4mm, 2.92mm, 3.5mm, MMCX,OSP, OSSP, SMA, SMB, SMC, SMP, SSMA,SSMB, SSMP, TNC, Type N, ZMA
SR141: 2.92mm, 3.5mm, SMA, TNC, Type N
SR250: SMA, Type N
(maximum frequency dependent on cable;other connectors available)
Semi-Rigid Cables (cont’d)
2098 West Main Street, Stroudsburg, PA 18360Tel: 1-877-MegaPhase / 570-424-8400
Fax: 1-877-MegaFax / 570-424-6031Email: [email protected] / Web: www.megaphase.com
Excellence in RF Interconnects
Frequency
GHz
0.30.50.81.02.02.43.04.06.08.010.012.415.018.020.022.024.026.528.030.032.034.036.040.045.050.0
UHF
L
S
C
X
Ku
K
Ka
QV
Band
Conn.Loss dB
0.0060.0090.0120.0140.0240.0270.0320.0400.0550.0700.0840.1010.1180.1390.1520.1650.1780.1940.2040.2170.2300.2430.2560.2810.3130.344
Attenuation Attenuation Attenuation Attenuation
dB/ft
SR034 SR047 SR086 SR250SR141
dB/m
0.3270.4230.5360.6000.8530.9361.0491.2151.4961.7361.9492.1802.4072.6492.8002.9443.0833.2493.3463.4713.5923.7103.8264.0484.3134.565
1.0721.3871.7581.9692.7983.0713.4413.9864.9095.6956.3947.1517.8998.6919.1879.66010.11510.66010.97711.38711.78512.17312.55113.28114.15014.979
dB/ft dB/m
0.2170.2810.3570.4000.5700.6260.7020.8141.0051.1681.3141.4721.6291.7961.9002.0002.0962.2122.2792.3662.4512.5342.6152.7712.9573.136
0.7130.9231.1721.3121.8702.0532.3032.6723.2983.8334.3114.8305.3445.8916.2346.5626.8787.2577.4787.7648.0438.3148.5799.0919.70310.288
dB/ft dB/m
0.1170.1530.1950.2200.3190.3530.3990.4680.5880.6940.7910.8981.0071.1251.2001.2731.3441.4301.4801.5461.6111.6751.7381.8602.0092.153
0.3840.5010.6410.7221.0481.1571.3081.5351.9302.2782.5952.9473.3043.6913.9374.1764.4084.6914.8565.0735.2865.4955.7016.1036.5917.064
1.10
1.15
1.201.25
1.30
1.35
1.40
1.45
1.50
1.55
VSWR
dB/ft dB/m
0.0390.0510.0660.0750.1120.1240.1420.1690.2170.2600.3010.3470.3940.446
------------
0.1270.1680.2170.2460.3660.4070.4650.5530.7110.8540.9871.1381.2931.464
------------
Attenuation
dB/ft dB/m
0.0630.0830.1060.1200.1760.1950.2210.2610.3310.3940.4510.5160.5820.6540.7000.7450.7890.8420.8740.9150.9560.996
----
0.2070.2710.3490.3940.5770.6390.7260.8561.0871.2921.4811.6931.9092.1452.2972.4442.5882.7642.8673.0033.1363.268
----
Note: Typical Insertion Loss dB = (Attenuation)(Length) + 2(Conn. Loss)Attenuation at any frequency = SR034: (0.59248 x √freq GHz) + (0.00752 x freq GHz), SR047: (0.39284 x √freq GHz) + (0.00716 x freq GHz), SR086: (0.20608 x √freq GHz) + (0.01392 x freq GHz), SR141: (0.10948 x √freq GHz) + (0.01052 x freq GHz), SR250: (0.06569 x √freq GHz) + (0.00931 x freq GHz)
Specifications
0 20105 30 402515 35 45 50
Frequency (GHz)
IL/ft
5
4
3
1
2
0
SR047
SR086
SR141SR250
SR034
Insertion Loss
0.1 0.3 1.0 3.0 10.0 30.0 100.0
Frequency (GHz)
Pmax (W
atts CW)
10000
1000
100
10
1
SR047
SR086
SR141
SR250
SR034
Note: Data at ambient temperature and sea level. Power handling of a cable assembly is also connector dependentand includes variables such as altitude, temperature and system VSWR. See website for connector power handlingstandards, including altitude, temperature and VSWR derating.
Cable CW Power Handling