ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des...

17
Equipement / Equipment : Récipient sous pression / Pressure vessel Capacité / capacity : Pression de service / service pressure : Référence / reference : Pression d'épreuve / test pressure : Nature du fluide / type of fluid : Température de service / service temperature : Tube utilisé / used tube : Matière / material : N° plan / drawing N° : Nbre cycles à ΔPmax / cycles number at ΔPmax Calcul basé sur norme / Calculation based on standard : AD2000-Merkblatt B0, B1, B3, B9, B10, S1 Normes harmonisées applicables / Applicable harmonized standard : Néant / none Autre directive applicable / other applicable directive : Néant / none. Module D "Assurance Qualité Production" / "Production Quality Assurance" : CE-0062-PED-D-RTM-001-15-FRA-revC Module B "Examen CE/UE de type" / EC/EU type examination : to to to to Contrôle réception matière / control of material at reception : Conforme / conform Traitement thermique réalisé / accomplished heat treatment : Conforme / conform Résultats d'essais mécaniques / mechanical tests results : Conforme / conform Test hydrostatique réalisé / accomplished hydrostatic test : 100% Conforme / conform Contrôle marquage / control of marking : Conforme / conform Contrôle visuel / visual control : Conforme / conform Contrôle dimensionnel / dimensionnal control : Conforme / conform Date d'épreuve / hydrostatic test date Signature au nom du fabricant / signed on behalf of the manufacturer : Nom / name : N. Bailly Resp. Technique & Qualité / Technical & Quality Resp. Date / date : fait à Mions / signed at Mions 50 L 360 bar ROTH Mions S.A.S. 43, rue des Brosses 69780 Mions - France Tél 04 72 28 15 60 Fax 04 78 21 16 26 Déclaration UE de conformité (Directive 2014/68/UE) EU Declaration of conformity (2014/68/EU Directive) Le fabricant ROTH Mions SAS, soussigné, certifie, sous sa seule responsabilité, que les équipements mentionnés ci-dessous satisfont aux exigences de la directive 2014/68/UE. Les équipements et composants mentionnés ci-dessous ont été fabriqués en accord avec les spécifications techniques cités ci-dessous, et l'évaluation de conformité à la directive a été établie par Bureau Véritas S.A., Newtime, 52 boulevard du Parc, Ile de la Jatte, 92200 Neuilly sur Seine, France, organisme notifié n° 0062. The undersigned ROTH Mions SAS manufacturer certifies under its own responsibility, that the equipments specified below satisfy the requirements of the 2014/68/EU directive. The equipments and components specified below have been manufactured in accordance with the technical specifications described below and the conformity assessment to the directive has been established by Bureau Véritas S.A., Newtime, 52 boulevard du Parc, Ile de la Jatte, 92200 Neuilly sur Seine, France, notified body n° 0062. Qté / Qty : 50 pièces / parts 50 L G 360 bar 515 bar Groupe 1 (art.2 Reg n°1272/2008) -40/+80°C 219,1 x 8,35 mm mini 34CrMo4-SPEC014 Repère coulée Material heat code Fabricant tube Tube manufacturer N° lot Batch N° RT551 - 810240 4093 N° série Serial N° N° coulée matière Material heat N° SA301 28653 28692 373255 HD Vallourec - Rath-Stopfen TA229 28643 28652 320557 DZ Vallourec - Rath-Stopfen 219,1 mm Ouverture 2 : diam maxi x épaisseur / Opening 2 : diam maxi x thickness 26,725 x 13,5 mm CE-PED-B-RTM 007-13-FRA rev.C type : A010.800/AD/CrMo Epaisseur mini partie cylindrique / Mini Thickness at cylindrical part 8,35 mm Longueur hors tout / Maxi length 1825 mm Ouverture 1 : diam maxi x épaisseur / Opening 1 : diam maxi x thickness 26,725 x 13,5 mm 18/09/2017 Les équipements sont déclarés CONFORMES / Equipments are declared CONFORM. 19/09/2017 Dimensions principales / Main dimensionnal caracteristics Diamètre extérieur / Outside Diametre

Transcript of ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des...

Page 1: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English

Equipement / Equipment : Récipient sous pression / Pressure vessel

Capacité / capacity : Pression de service / service pressure :

Référence / reference : Pression d'épreuve / test pressure :

Nature du fluide / type of fluid : Température de service / service temperature :

Tube utilisé / used tube : Matière / material :

N° plan / drawing N° : Nbre cycles à ΔPmax / cycles number at ΔPmax :

Calcul basé sur norme / Calculation based on standard : AD2000-Merkblatt B0, B1, B3, B9, B10, S1

Normes harmonisées applicables / Applicable harmonized standard : Néant / none

Autre directive applicable / other applicable directive : Néant / none.

Module D "Assurance Qualité Production" / "Production Quality Assurance" : CE-0062-PED-D-RTM-001-15-FRA-revC

Module B "Examen CE/UE de type" / EC/EU type examination :

to

to

to

to

Contrôle réception matière / control of material at reception : Conforme / conform

Traitement thermique réalisé / accomplished heat treatment : Conforme / conform

Résultats d'essais mécaniques / mechanical tests results : Conforme / conform

Test hydrostatique réalisé / accomplished hydrostatic test : 100% Conforme / conform

Contrôle marquage / control of marking : Conforme / conform

Contrôle visuel / visual control : Conforme / conform

Contrôle dimensionnel / dimensionnal control : Conforme / conform

Date d'épreuve / hydrostatic test date :

Signature au nom du fabricant / signed on behalf of the manufacturer :

Nom / name : N. BaillyResp. Technique & Qualité / Technical & Quality Resp.

Date / date : fait à Mions / signed at Mions

50 L 360 bar

ROTH Mions S.A.S.

43, rue des Brosses

69780 Mions - France

Tél 04 72 28 15 60

Fax 04 78 21 16 26

Déclaration UE de conformité (Directive 2014/68/UE)

EU Declaration of conformity (2014/68/EU Directive)

Le fabricant ROTH Mions SAS, soussigné, certifie, sous sa seule responsabilité, que les équipements mentionnés ci-dessous satisfont aux

exigences de la directive 2014/68/UE. Les équipements et composants mentionnés ci-dessous ont été fabriqués en accord avec les spécifications

techniques cités ci-dessous, et l'évaluation de conformité à la directive a été établie par Bureau Véritas S.A., Newtime, 52 boulevard du Parc, Ile de

la Jatte, 92200 Neuilly sur Seine, France, organisme notifié n° 0062.

The undersigned ROTH Mions SAS manufacturer certifies under its own responsibility, that the equipments specified below satisfy the

requirements of the 2014/68/EU directive. The equipments and components specified below have been manufactured in accordance with the

technical specifications described below and the conformity assessment to the directive has been established by Bureau Véritas S.A., Newtime, 52

boulevard du Parc, Ile de la Jatte, 92200 Neuilly sur Seine, France, notified body n° 0062.

Qté / Qty : 50 pièces / parts

50 L G 360 bar 515 bar

Groupe 1 (art.2 Reg n°1272/2008) -40/+80°C

219,1 x 8,35 mm mini 34CrMo4-SPEC014

Repère coulée

Material heat code

Fabricant tube

Tube manufacturerN° lot

Batch N°

RT551 - 810240 4093

N° série

Serial N°

N° coulée matière

Material heat N°

SA301

28653 28692 373255 HD Vallourec - Rath-Stopfen TA229

28643 28652 320557 DZ Vallourec - Rath-Stopfen

219,1 mm

Ouverture 2 : diam maxi x épaisseur / Opening 2 : diam maxi x thickness 26,725 x 13,5 mm

CE-PED-B-RTM 007-13-FRA rev.C type : A010.800/AD/CrMo

Epaisseur mini partie cylindrique / Mini Thickness at cylindrical part 8,35 mm

Longueur hors tout / Maxi length 1825 mm

Ouverture 1 : diam maxi x épaisseur / Opening 1 : diam maxi x thickness 26,725 x 13,5 mm

18/09/2017

Les équipements sont déclarés CONFORMES / Equipments are declared CONFORM.

19/09/2017

Dimensions principales / Main dimensionnal caracteristics

Diamètre extérieur / Outside Diametre

Page 2: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English

ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS

Instructions Manual for pressure vessels

NIT PED v05 English version

Page 1 sur 4

Be careful, this shell is a pressure vessel. Failure to follow instructions may result a danger for the security of people and goods.

To preserve the quality of your product from delivery and throughout its use in the best conditions of security, it is recommended that you read this manual carefully and strictly follow the instructions it contains. 1. Description

Use : The vessel function is to store pressurized fluids. The vessel itself cannot store fluid under pressure. It has to be equipped with suitable pieces defined by the manufacturer of those pieces. The vessel can store different fluids, depending of its application : - Hydraulic oil and Nitrogen for bladder accumulator

(fluids of group 2). - Hydrogen. Hydrogen gives fragility to the steel.

(fluid of group 1). Declaration of conformity mentions “Hydrogen” and marking indicates “H2”.

- Compressed air for diving bottle for example, Water (fluids of group 2).

- Compressed oxygen. Combustion fluid. (fluid of group 1).

- For the other applications or particular fluids, ROTH has to be informed by the fitter, before filling the vessel.

The vessel cannot store corrosive fluids. The vessel is not defined for Transportation of Fluids. Regulation : The vessel is conforming to European Directive 2014/68/UE concerning Equipments under pressure. It is a vessel homologated under Category IV. Therefore, the vessel is approved following conformity evaluation procedure module B+D ; this conformity evaluation procedure allows the vessel to be homologated for lower categories. The vessel is able to store fluids of group 1 and/or group 2 as defined in the European rule CLP 1272/2008 and following above restrictions (see fluid group mentioned in UE Declaration of conformity). Fabrication : The vessel is manufactured in seamless steel, forged at each ends.

2. Technical feature

Some technical features are mentioned in the Conformity Declaration or may be stamped on the product (see §4).

ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS

Instructions Manual for pressure vessels

NIT PED v05 English version

Page 2 sur 4

Storing Temperature (vessel without pressure)

-60°C to +350°C

Maxi Temperature for applying coating 350°C

Weight depending on model 4 kg to 150 kg

Standard delivery conditions (except specific request) – Internal protection

Dessicant bag or oil spread inside the vessel. Cap at each end.

Standard delivery conditions (except specific request) – External protection

Primary coating or finishing paint or anticorrosive protection or without. Anticorrosive protection + finishing paint for diving bottles.

Fatigue calculation is done following recognized Code. Cycle numbers is depending on the vessel delta pressure of use (see cycles number on Declaration of Conformity). For diving bottles, cycle number is defined in Manufacturing standard.

3. Instructions

Instructions shall be considered during all the life of the vessel, it means for the shell alone, for the shell equipped, before and during use, and at the end of its life. It concerns handling, storing, installation, fixing, commissioning, use, maintenance, removal, disposal or recycling.

3.1 Handling, storage, installation

Handling : The vessel shall be handled with care to save it against shocks or stresses which can deform, scratch, crack or create metal wrenching. Once installed, if necessary, protection around the vessel shall be provided. For heavy vessel, a magnet, belt or other suitable means may be used for handling. During transportation, the vessel shall be packed in suitable packaging : carton, container, plastic coated pieces secured on pallets... Packaging shall be done with a limited number of levels depending on the size of the vessels. During handling, the vessel weight shall be well considered. Storage : Storage shall be made out of the weather, moisture, runoff, condensation. Storage temperature : see §2. The vessel shall be protected with same means than delivery : see §2. Protection : The vessel shall be protected against anything which may cause a corrosive action, whether inside or outside. Depending on the conditions of use and location, the vessel can be coated with a protective paint or other coating. The compatibility of the coating and application temperature shall be checked to be in conformance with requirements of §2. Installation :

Page 3: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English

ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS

Instructions Manual for pressure vessels

NIT PED v05 English version

Page 3 sur 4

During installation and before the first pressurization, the fitter shall visually check that the vessel has suffered no damage. If the manufacturer ROTH has not stamped the group of fluid (and its possible nature if necessary) in the initial marking of the vessel, the fluid is from group 2 and non corrosive for the tube walls. The vessel shall be equipped at ends with connecting pieces designed and manufactured in conformance with the design of the vessel. It is recommended to fix the vessel using suitable clamps adapted to the diameter of the vessel, and suitable supports for the hemispherical part. It is forbidden to carry out a repair by welding, drilling, riveting or any operation creating a removal of material, or a rise in temperature. Compatibility of the fluid with steel and with possible internal and external protection elements shall be checked. A pressure relief system on the equipment or installation shall be fitted to avoid the system pressure becomes over the maximum allowable pressure of the vessel. The filled fluid shall not increase the internal defined pressure at temperature of use. Regulations in force shall be followed during installation. Additional recommendations : The vessel shall not be exposed to the action of flame or sparks. The vessel shall not be exposed to the effect of electric and magnetic fields which could create sparks or overheating. The vessel shall be protected against the effects of lightning. The vessel shall not be installed and used as a structural component and shall not be used to support other components or assemblies. The vessel shall not be exposed to external loads.

3.2 Use

Temperature and pressure phenomena : In use, an increase of temperature involves an increase of pressure ; likewise a pressure variation generates a temperature change (an increase of pressure generates an increase of temperature, and a relaxation of the pressure generates a temperature decrease). The user shall ensure these behaviors to avoid exceeding the vessel limits of use.

Inspection and periodical follow up : The user is responsible of following up periodical inspections according to regulatory requirements. In addition and depending on use, the user shall regularly check that the vessel does not show evidence of deterioration such as corrosion, deformation, shock, leak, crack... Wear and fatigue phenomena : In case of use with abrasive fluid, a filter shall be fitted on the installation. Depending on the conditions of use, fatigue phenomena may occur. The user shall regularly proceed to inspection of the general condition of the vessel.

3.3 Maintenance, dismantling, destruction, recycling

ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS

Instructions Manual for pressure vessels

NIT PED v05 English version

Page 4 sur 4

Before any maintenance or disassembly on the vessel equipped with connecting pieces, the pressure lines shall be purged, and the absence of residual pressure inside the vessel shall be ensured. Before destruction or recycling, the pressure lines shall be purged, and the absence of residual pressure inside the vessel shall be ensured. If necessary, the remaining gas shall be removed using a neutral gas.

3.4 For other situations, please ask to ROTH. 4. Marking

The vessel is marked with the following non-exhaustive information in a reinforced area so as not to weaken the part.

ROTH Name or brandt symbol of the manufacturer

ZZZZZ Name or brandt symbol of the customer, if any

AAAA Manufacturing year

XXXX Serial number of the vessel

PS ____ BAR Maximum allowable working pressure, in bar

TS __/__°C Temperature of use, in degree Celsius

V XX L Capacity, in litre

XXXX Use (ACCU for example)

PT ___ BAR Test pressure, in bar

AAAA / MM Date of test pressure, year/month

CE XXXX CE mark followed by notified body N°

XXXX Notified body n°

XXXX Group (preceded by G or GROUP) or nature of the allowed fluid, if any

XXXX Diving bottle : thread information

XXXX KG/L Maxi filling rate, if any

CH XX KG Filling mass, if any

XXXX KG Mass of the vessel (with accessory), if any

The user shall not change the marking unless having ROTH authorization. In case of additional marking (specific instructions, re-testing during inspections...), it shall be done in the reinforced hemispherical area, and it shall not be confused with the initial marking. No writing or marking insculpation is allowed on the cylindrical area of the vessel. The marking operation shall not cause temperature rise beyond the temperature of use. The marking shall not generate excessive stresses on the vessel.

Page 4: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 5: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 6: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 7: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 8: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 9: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 10: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 11: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 12: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 13: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 14: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 15: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 16: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English
Page 17: ROTH Mions S.A.S. 43, rue des Brosses Déclaration UE de ... · ROTH Mions S.A.S. 43, rue des Brosses F – 69780 - MIONS Instructions Manual for pressure vessels NIT PED v05 English