Pulses in transmission lines Physics 401, Spring 2018 Eugene V. Colla

Transcript of Pulses in transmission lines - University of Illinois ...

Page 1: Pulses in transmission lines - University of Illinois ...

Pulses in transmission lines

Physics 401, Spring 2018Eugene V. Colla

Page 2: Pulses in transmission lines - University of Illinois ...

• Definition

• Distributed parameters network

• Pulses in transmission line

• Wave equation and wave propagation

• Reflections. Resistive load

• Thévenin's theorem

• Reflection. Non resistive load

• Appendix. Error propagation

2/5/2018 2Spring 2016

Page 3: Pulses in transmission lines - University of Illinois ...

2/5/2018 3Spring 2016

1.Networks with distributed parameters

2.Propagation of pulses in transmission lines

3.Impedance matching

Page 4: Pulses in transmission lines - University of Illinois ...

• Transmission line is a specialized cable

designed to carry alternating current of radio

frequency, that is, currents with a frequency

high enough that its wave nature must be

taken into account.

Courtesy Wikipedia

2/5/2018 4Spring 2016

Page 5: Pulses in transmission lines - University of Illinois ...

LiLi-1 Li+1

CiCi-1 Ci+1

Idealcase

Ci

Gi+1

LiRi Real situation

Simplified equalent

circuit

2/5/2018 5Spring 2016

Page 6: Pulses in transmission lines - University of Illinois ...

2/5/2018 6Spring 2016

Coaxial cable Courtesy Analog Devices

Twisted lineCourtesy Wikipedia

Twin leadCourtesy Wikipedia

Page 7: Pulses in transmission lines - University of Illinois ...

Specification:Impedance: 53 ΩCapacitance: 83 pF/mConductor: Bare Copper Wire (1/1.02mm)

2/5/2018 7Spring 2016

Page 8: Pulses in transmission lines - University of Illinois ...

V(t) V(x,t)

x

ZL

rout i(x,t)

V0 forward

reflected

2/5/2018 8Spring 2016

Page 9: Pulses in transmission lines - University of Illinois ...

Load

RG8U

Wavetek 81 Tektronix 3012B

Triggering input

Sync output

Signal output

2/5/2018 9Spring 2016

Page 10: Pulses in transmission lines - University of Illinois ...

V(t) V(x,t)

x

rout

i(x,t)

dxC = capacitance per unit lengthL = inductance per unit length

;

;

CdxV dq

V qC i

t t

i V= -C

x t

( ) ;

didV Ldx

dt

V iL

x dt

2/5/2018 10Spring 2016

Page 11: Pulses in transmission lines - University of Illinois ...

i V= -C

x t

V iL

x dt

t

x

tx

iL

x

V

2

2

2

2

22

t

VC

xt

i

(1) (2)

Combining (1) and (2)

2 2

2 2

V VLC

x t

2 2

2 2

i iLC

x t2/5/2018 11Spring 2016

Page 12: Pulses in transmission lines - University of Illinois ...

2 2

2 2

V VLC

x t

2 2

2 2

i iLC

x t

0( , ) sin

xV x t V t

v

0( , ) sin

xi x t i t

v

Looking for solution

1

vLC

Speed of wavepropagation

V iL

x dt

Now substituting V(x,t) and i(x,t) in

We can find or 0 0

LV i

C

( , ) ( , ) ( , ) k

LV x t i x t Z i x t

C Zk - characteristic Impedance

Equivalent to Ohm’s law equation

i V= -C

x t

2/5/2018 12Spring 2016

Page 13: Pulses in transmission lines - University of Illinois ...

k

LZ =

C

C = capacitance per unit lengthL = inductance per unit length

Cross-section of the coaxial cable

Dd

0 r2πε ε

C=D

lnd

(F/m)

-12

0ε =8.854×10 (F/m)

er – dielectric permittivitymr-magnetic permeability ≈1

0 ln2

m m

r D

Ld

-7

0=4 ×10 (H/m)m

(H/m)

Finally for coaxial cable: 138

log ( )e

k

r

DZ Ohms

d

2/5/2018 13Spring 2016

Page 14: Pulses in transmission lines - University of Illinois ...

1

=LC

Speed of wavepropagation

1

=0 0

m m e e m e e

r r r r r

c c

Delay time (s/m) ≈

For polyethylene er~2.25(up to 1GHz)

1

9

3.336 10 ( / ) 3.336 ( / )e er r

s m ns m

RG-8/U, RG58U:

Inner Insulation Materials: Polyethylene Nominal Impedance: 52 ohm Delay time ~5ns/m

1

2/5/2018 14Spring 2016

Page 15: Pulses in transmission lines - University of Illinois ...

x

ZL

forward

reflected

...

...

2 2

2 2

V VLC

x t

solution for the traveling in opposite direction

For reflected wave Vr=-Zkir

0( , ) sin

xV x t V t

v

0( , ) sin

xi x t i t

v

2/5/2018 15Spring 2016

Page 16: Pulses in transmission lines - University of Illinois ...

x

ZL

forward

reflected

...

...

Vr=-Zkir

At any point of the transmission line:

r i

i r

r i

k k

V V V

V Vi i i

Z Z

1. Resistive load ZL=RL

L

VR

i

i r L

i r k

V V R

V V Z

or L k

r i

L k

R ZV V

R Z

2/5/2018 16Spring 2016

Page 17: Pulses in transmission lines - University of Illinois ...

Resistive load ZL=RL

i r L

i r k

V V R

V V Z

orL k

r i

L k

R ZV V

R Z

Open line RL=∞ → Vr = Vi and VL=Vi + Vr = 2Vi (on the load)

Incident pulse

Reflected pulse End of the line

2/5/2018 17Spring 2016

Page 18: Pulses in transmission lines - University of Illinois ...

Theory: RL=∞ → Vr = Vi

Attenuation (dB per 100 feet)

MHz 30 50 100 146 150

RG-58U 2.5 4.1 5.3 6.1 6.1

Experiment RG 58U

Vi

Vr

incident

reflected

( ) 20log i

r

VATTN db

V

Important parameter forcable is attenuation perlength

2/5/2018 18Spring 2016

Page 19: Pulses in transmission lines - University of Illinois ...

( ) 20log i

r

VATTN db

V

2/5/2018 19Spring 2016

Alexander Graham Bell 1847 – 1922)

This unit was named the bel, in honor of their founder and

telecommunications pioneer Alexander Graham Bell

The decibel (dB) is one tenth of the bel (B): 1B = 10dB.

110

2

( ) 10 logP

L dbP

power ratio

110

2

( ) 20 logV

L dbV

voltage (current, field…) ratio

In case of our transmission line:

Page 20: Pulses in transmission lines - University of Illinois ...

In our case:4.18

(200 ) 20log 1.463.54

Attn ft dB

Where it is coming from?

Ci

Gi+1

LiRi

2/5/2018 20Spring 2016

Page 21: Pulses in transmission lines - University of Illinois ...

4.18(200 ) 20log 1.46

3.54Attn ft dB

3.932(200 ) 20log 0.335

3.78Attn ft dB

RG-58U RG-8U

Core ø=0.81 mm

Dielectric ø=2.9 mm

Core ø=2.17 mm

Dielectric ø=7.2 mm

>

2/5/2018 21Spring 2016

Page 22: Pulses in transmission lines - University of Illinois ...

RG-58U

Reflected pulse does not follow the shape of the incident pulse

Frequency dependence of the attenuation RG-58U cable

2/5/2018 22Spring 2016

Page 23: Pulses in transmission lines - University of Illinois ...

FFT Spectrum correction

Incident pulse spectrumreflected pulse spectrum

IFFT

2/5/2018 23Spring 2016

Page 24: Pulses in transmission lines - University of Illinois ...

Resistive load ZL=RLi r L

i r k

V V R

V V Z

orL k

r i

L k

R ZV V

R Z

Shorted line RL=0 → Vr = - Vi

-200 0 200 400 600 800

-2.5

-2.0

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

2.0

2.5

3.0

V(V

)

time (ns)

Incident pulse

Reflected pulse

2/5/2018 24Spring 2016

Page 25: Pulses in transmission lines - University of Illinois ...

Resistive load ZL=RL i r L

i r k

V V R

V V Z

orL k

r i

L k

R ZV V

R Z

Matching the load impedance RL → Zk; Vr → 0

0 100 200 300 400 500 600 700 800

-0.2

0.0

0.2

0.4

0.6

0.8 24.8

179.9

100.2

149.6

50

time (ns)

V (

V)

0 200 400

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

V(V

)

time (ns)

0 200 400

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

V(V

)

time (ns)

Incident pulse

End of the line

Incident pulse

Reflected pulse

2/5/2018 25Spring 2016

Page 26: Pulses in transmission lines - University of Illinois ...

Léon Charles Thévenin(1857–1926)

Hermann Ludwig Ferdinand von Helmholtz

(1821-1894)

Any combination of batteries andresistances with two terminals can be

replaced by a single voltage source eand a single series resistor r

+

-

+

-

R1 R4

R2 R3

E1 E2

+

-

e

r

2/5/2018 26Spring 2016

Page 27: Pulses in transmission lines - University of Illinois ...

r i L

i r

r i

k k

V V V i R

V Vi i i

Z Z

i

L k

Vi

R Z

2

From this equivalent equation we can find the maximum possible power delivered to RL

i

L L

L

V

P i R R

R Z

2

2

2

2

P=Pmax if RL=Zk (no reflection)

2Vi

Zk

RL

2/5/2018 27Spring 2016

Page 28: Pulses in transmission lines - University of Illinois ...

2Vi

Zk

RL

This experiment better to perform on RG 8U cable because of lower attenuation

RL=, amplitude of the pulse at the end of line is expected to be 2Vi, where Vi is the amplitude of the incident pulse

RG 8U

incidentreflected

Pulse at the end of the line

2/5/2018 28Spring 2016

Page 29: Pulses in transmission lines - University of Illinois ...

i

L k

Vi

Z Z

2

V0

Zk

C

.

k

k

Z C

C nF

Z

3 2

2/5/2018 29Spring 2016

L

tV exp

1

L i

t TTV V exp exp

112 1

T1

T1

Page 30: Pulses in transmission lines - University of Illinois ...

i

L k

Vi

Z Z

2

V0

L

Zk

;

exp ;

i k

diV iZ L

dt

ti i

0

2

1

k

L

Z

50ns, L=𝒁𝒌~𝟐. 𝟓m𝑯

2/5/2018 30Spring 2016

Page 31: Pulses in transmission lines - University of Illinois ...

i

L k

Vi

Z Z

2

V0

L

Zk

;

exp ;

i k

diV iZ L

dt

ti i

0

2

1

k

L

Z

0

10

20

-10

0

10

20

-10 0 10 20 30 40 50 60-10

0

10

20

time

Vi

VL

Vr= VL - Vi

2/5/2018 31Spring 2016

Page 32: Pulses in transmission lines - University of Illinois ...

2/5/2018 32Spring 2016

Page 33: Pulses in transmission lines - University of Illinois ...

1. The reports should be uploaded to the proper folder and only to

the proper folder

L1_lab3_student1

Lab section Lab number Your name

2. Origin template for this week Lab:

\\engr-file-03\phyinst\APL Courses\PHYCS401\Common\Origin templates\Transmission line\Time trace.otp

2/5/2018 33Spring 2016

For example folder Frequency domain analys_L1 should used by students from L1 section only

I would recommend the file name style as:

You do not need to submit two copies in pdf and in MsWord formats

Page 34: Pulses in transmission lines - University of Illinois ...

y = f(x1, x2 ... xn)2

2

1

( , )n

i i i

i i

ff x x x

x

1 1.5

1.10

1.15

xi

f(x

i)

xi±∆xi

f±fx

2/5/2018 34Spring 2016

Page 35: Pulses in transmission lines - University of Illinois ...

Derive resonance frequency ffrom measured inductanceL±∆L and capacitance C±∆C

0

1

1( , )

2

f L CLC

1 110 1mH, 10 2μFL C

2 2

2 2( , , , )

f ff L C L C L C

L C

1 3

2 2

1 3

2 2

1;

4

1

4

fC L

L

fL C

C

Results: f(L1,C1)=503.29212104487Hz∆f=56.26977Hz

f(L1,C1)=503±56Hz

2/5/2018 35Spring 2016

Page 36: Pulses in transmission lines - University of Illinois ...

1 110 1mH, 10 1μFL C Where these numbers are coming from?

1. Using commercial resistors, capacitors, inductances…

C=500pF±5% L=35mH±10%

2. Measuring the parameters using standard equipment

SENCORE “Z” meter model LC53Capacitance measuring accuracy ±5%Inductance measuring accuracy ±2%

Basic accuracy ±0.05%

Agilent E4980A Precision LCR Meter

2/5/2018 36Spring 2016

Page 37: Pulses in transmission lines - University of Illinois ...

2/5/2018 37Spring 2016

Origin uses the Levenberg–Marquardt algorithm for nonlinear fitting

From experiment you have the array (xi,yi) of independent and dependent

variables: xi (e.g. f- frequency) and yi (e.g. magnitude of the signal) and you have

optimize the vector of fitting parameters b of your model function f(x,b) in order

to minimize the sum of squares of deviations:

2

1

( ) ( , )m

i i

i

S y f xb b

Important point is the choice of fitting parameters. In some cases the algorithm

will work with b=(1,1…1) , but in many situations the choice of more realistic

parameters will lead to solution

For details go to: http://en.wikipedia.org/wiki/Levenberg%E2%80%93Marquardt_algorithmK. Levenberg. “A Method for the Solution of Certain Non-Linear Problems in Least Squares”.The Quarterly of Applied Mathematics, 2: 164-168 (1944).

Page 38: Pulses in transmission lines - University of Illinois ...

• Transmission line. Unknown load simulation

38

X-axes scalingFunction generator parameters

Line characteristic impedance

Expected load

Load parameters

Location:\\engr-file-03\PHYINST\APL Courses\PHYCS401\Lab Software And Manuals\LabSoftware\Transmission lines

2/5/2018 Spring 2016

Page 39: Pulses in transmission lines - University of Illinois ...

• Transmission line. Unknown load simulation

Location:\\engr-file-03\PHYINST\APL Courses\PHYCS401\Lab Software And Manuals\LabSoftware\Transmission lines

2/5/2018 Spring 2016 39