Mass measurements with (d,p) transfer reactions

30
Mass measurements with (d,p) transfer reactions Mass measurements with (d,p) transfer reactions Mark Wallace 06/10/05 Mark Wallace 06/10/05

Transcript of Mass measurements with (d,p) transfer reactions

Page 1: Mass measurements with (d,p) transfer reactions

Massmeasurements with (d,p)

transfer reactions

Massmeasurements with (d,p)

transfer reactions

Mark Wallace06/10/05

Mark Wallace06/10/05

Page 2: Mass measurements with (d,p) transfer reactions

Experimental ProgramExperimental Program

Measure the Mass of 64Ge and 65As to calculate the Q-Value of 64Ge(p,γ)65AsUse (p,d) Transfer Reactions in Inverse Kinematics

Produce 66As and 65Ge Beams.CH2 Target for Protons

Magnetic Spectrometer to separate reactions products.Measure Deuterons from (p,d) in Charged Particle ArrayMeasure Reaction Angle with Position Sensitive Beam Tracking Detectors

Measure the Mass of 64Ge and 65As to calculate the Q-Value of 64Ge(p,γ)65AsUse (p,d) Transfer Reactions in Inverse Kinematics

Produce 66As and 65Ge Beams.CH2 Target for Protons

Magnetic Spectrometer to separate reactions products.Measure Deuterons from (p,d) in Charged Particle ArrayMeasure Reaction Angle with Position Sensitive Beam Tracking Detectors

Page 3: Mass measurements with (d,p) transfer reactions

How Do We Measure These Nuclear Masses?

How Do We Measure These Nuclear Masses?

M65As2 = M66As

2 + Mp2 + Md

2

+2 E66AsMp − Ed Mp − E66AsMd + E66As2 − M66As

2 Ed2 − Md

2Cos(α)[ ]

Using Inverse Kinematics:(p,d)

Use Heavy Beam Particle.

Heavy Fragment Which Has An Unknown Mass

The Proton is in a CH2 target or a Frozen Hydrogen Target

66As p

d

65As

α

Page 4: Mass measurements with (d,p) transfer reactions

Inverse KinematicsInverse Kinematics

vcmθlab

VdLab

Vdcm

VbeamLab

θcm

Deuteron

VHcm

Page 5: Mass measurements with (d,p) transfer reactions

Cross Section in Inverse KinematicsCross Section in Inverse Kinematics

65Ge(p,d)64GeAt 60 MeV/u

Page 6: Mass measurements with (d,p) transfer reactions

Generating the Radioactive BeamGenerating the Radioactive Beam

Page 7: Mass measurements with (d,p) transfer reactions

The S800 SpectrographThe S800 Spectrograph

Page 8: Mass measurements with (d,p) transfer reactions

Dispersion

Matching

Dispersion

Matching

Only 3 keV/mmEffect From Beam Energy using Dispersion Matching in S800

Page 9: Mass measurements with (d,p) transfer reactions

Resolution

Effects

Resolution

Effects

Slope of these lines1.8 keVmass/keVdeu61 keV/mm or16 keV/mrad

Page 10: Mass measurements with (d,p) transfer reactions

Target EffectTarget Effect

Slope71 keV/mg/cm2

Page 11: Mass measurements with (d,p) transfer reactions

Kinematic

Broadening

Kinematic

Broadening

ve

http://www.phys.ksu.edu/~benis/

Page 12: Mass measurements with (d,p) transfer reactions
Page 13: Mass measurements with (d,p) transfer reactions
Page 14: Mass measurements with (d,p) transfer reactions

Laser Based Alignment System• Designed for precision measurement of detector positions relative to target.• Adaptable to various configurations and other devices.• Computer controlled.

•Resolution:• ±0.005° for angular stages.• 100 microns for distance.

Page 15: Mass measurements with (d,p) transfer reactions

Beam Tracking Using Micro Channel Plate Detectors

Beam Tracking Using Micro Channel Plate Detectors

Beam

Foil

MCP

e-

anode

Primary Electron

Page 16: Mass measurements with (d,p) transfer reactions

Resolution of MCP Tracking System

Resolution of MCP Tracking System

Position: X ~0.35 mm FWHM - Y~0.74 mm FWHM

Time: ~ 600 ps FWHM

Beam Rates up to 1 MHz

Efficiency ~ 90 % at 1 MHz

Page 17: Mass measurements with (d,p) transfer reactions

• 20 Independent Telescopes

The High Resolution Array (HiRA)The High Resolution Array (HiRA)

Page 18: Mass measurements with (d,p) transfer reactions

4x CsI(Tl) 4cm

32 strips v. (front)Beam

Si-ΔE 65 μm

32 strips v (front)

Si-E 1.5 mm

pixel

32 strips h. (back)

The High Resolution Array (HiRA)

The High Resolution Array (HiRA)

Page 19: Mass measurements with (d,p) transfer reactions

Silicon DetectorsSilicon Detectors

•Bulk material is n type•Interstrip on junction side is 25 μm•Interstrip on ohmic side is 40 μm

•P+ implant for better interstrip isolation

•Depletion voltage for 1.5 mm detector < 500 V•10 guard ring structure on periphery (2mm dead area region)

• 62.3 x 62.3 mm2 Active Area• Pitch 1.95 mm• 1024 Pixels per telescope

Page 20: Mass measurements with (d,p) transfer reactions

SiliconEnergy

Resolution

SiliconEnergy

Resolution

Page 21: Mass measurements with (d,p) transfer reactions

Particle IdentificationParticle Identification

Page 22: Mass measurements with (d,p) transfer reactions

Electronic Readoutdeveloped at Washington University (St. Louis)

With 2000 channels to readout, cost of “traditional” readout is prohibitive.

Application Specific Integrated Circuit

Design Includes:• Multiple Preamps • Shapers• Discriminator• Time to amplitude converters

4 Ch prototype

16 Ch Production Chip

This chip board + one VME module replaces 32 pre-amp’s, 32 Shapers, 32 TDCs and 32 ADCs

Page 23: Mass measurements with (d,p) transfer reactions

2 different gain internal Charge Sensitive Amplifiers (CSA)

100 MeV & 500 MeV dynamic range

Bypass internal CSA for use with higher gain external CSA

Pseudo CFD - Leading edge trigger zero cross discriminator

Computer controlled threshold for each strip

Positive and negative signals

On off for each channel

ΔV∝T

Shaper

TVCStart

Stop

H

Disc

ASIC x 16

L

Peak FindAnd Hold

Peak FindAnd Hold

Diff-Amp

Diff-Amp

Hit Register

External Stop

ΔV∝E

- Inspect points

TVC 150 ns & 1 μs

Unity gain Shaper with 1 μs shaping time for both positive and negative signals

3 computer controlled Inspection points, shown with red dot

Multiplexed output of E & T signals through differential Amp into LVDS flash ADC.

Sparse readout based on hit register, or forced readout of all channels

pulser inputs, even or odd channels

Page 24: Mass measurements with (d,p) transfer reactions

HiRA Electronics Setup Behind Detectors in Vacuum ChamberHiRA Electronics Setup Behind Detectors in Vacuum Chamber

Page 25: Mass measurements with (d,p) transfer reactions

Differential Signals

Sample time

Signal Traces from Differential Amplifier to ADC

Signal Traces from Differential Amplifier to ADC

Page 26: Mass measurements with (d,p) transfer reactions

228Th α sourceFWHM=50 keV�228Th α sourceFWHM=50 keV�

Chip High Gain Pre-Amplifier Chip High Gain Pre-Amplifier

Page 27: Mass measurements with (d,p) transfer reactions

External 60 mV/MeV Pre-Amplifier + ASIC Chip

External 60 mV/MeV Pre-Amplifier + ASIC Chip

249Cf α sourceFWHM=30 keV�249Cf α sourceFWHM=30 keV�

Page 28: Mass measurements with (d,p) transfer reactions

Simulated 64Ge mass spectrum from 65Ge(p,d)64Ge

Simulated 64Ge mass spectrum from 65Ge(p,d)64Ge

Page 29: Mass measurements with (d,p) transfer reactions

Status and OutlookStatus and Outlook•Final Test of Entire system July 10th

•Initial Test of (p,d) experiment July 18th

•Measurement of 65As and 64Ge August

•Breakup Measurement of 69Br

•Measurements of 72Kr, 73Rb in the future

Page 30: Mass measurements with (d,p) transfer reactions

CollaboratorsCollaborators

IU / IUCF•RT.de Souza•A.L.Caraley•B.P.Davin•R.Alfaro-Molina•S.Hudan•A.Ryder•R.Yanez

•W.G. Lynch•M.B.Tsang•G.Verde•M-J. van Goethem•M.Famiano•F.Delaunay•A.Rogers•M.Mocko

MSU / NSCL

Washingon Univiersityof St.Louis

•L. Sobotka•R.Charity•J.M.Elson

Southern Illinois University, Edwardsville

•G.L Engel

INFN Milano•A.Moroni

ORNL•D.Shapira

Rutgers•K.Grzywacz-Jones