Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D new metal...

10
Gd Liquid scintillator: completion of the R&D! 420 440 460 480 500 520 540 560 580 600 0 ,0 00 0 ,0 02 0 ,0 04 0 ,0 06 0 ,0 08 0 ,0 10 0 ,0 12 0 ,0 14 0 ,0 16 0 ,0 18 0 ,0 20 absorbance w a ve le n g th [n m ] 29.09. 06.10. 25.10. 03.11. 17.11. Stability 0,1 % Gd in PXE R&D new metal β-diketone molecule (MPIK) le: 0.1% Gd-Acac (few months) line receipie ~80% mineral oil + ~20% PXE + Fluors + wavelenght shi oaded scintillators (0.1 %, 5% loading) are counting @Gran Sasso e stable receipies available (MPIK, INFN/LNGS) Gd-Acac molecule Completion of the R&D first half of 2004 Choice of the final scintillator Stability & Material compatibility Aging tests (MPIK, Sacla 3+ Gd
  • date post

    22-Dec-2015
  • Category

    Documents

  • view

    225
  • download

    0

Transcript of Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D new metal...

Page 1: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Gd Liquid scintillator: completion of the R&D!

420 440 460 480 500 520 540 560 580 6000,000

0,002

0,004

0,006

0,008

0,010

0,012

0,014

0,016

0,018

0,020

ab

sorb

an

ce

wavelength [nm]

29.09. 06.10. 25.10. 03.11. 17.11.

Stability 0,1 % Gd in PXE

LENS R&D new metal β-diketone molecule (MPIK)Stable: 0.1% Gd-Acac (few months) Baseline receipie ~80% mineral oil + ~20% PXE + Fluors + wavelenght shiftersIn-loaded scintillators (0.1 %, 5% loading) are counting @Gran SassoSpare stable receipies available (MPIK, INFN/LNGS)

Gd-Acac molecule

Completion of the R&D first half of 2004 Choice of the final scintillator Stability & Material compatibility Aging tests (MPIK, Saclay)

3+Gd

Page 2: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Gd Liquid scintillator tests in Saclay

Goal: 1/ Test the LONG term stability of the scintillator 2/ Test the material compatibility with acrylic, glue, ...

Towards the desgin of the acrylic vessels Tight stainless steel boxes flushed with N2 – 20- 130cl quartz cuvettesAeging test scintillator temperature ~50 degrees Systematic periodic photospectrometer absorbance measurements

Page 3: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Acrylic vessels

4m

2m

2.4m

3.6m

2.8m

Gamma catcherTarget

Thickness = 6mm

Final assembly (in several part)In Chooz’s site Assembly in the manufacturer

workshop

Page 4: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

•Suspension:3 points at 120

degrees•Thickness: 6 mm•Empty weight:

– Target = 220kg– Gamma catcher = 470kg

Maximum stress: 12 MPa

Stress in acrylic vessels

DAPNIA/SIS/LCAP - JMB

Target

Gamma catcher

Page 5: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Filling of vessels:

Dosing pums (diaphragm pumps or peristaltic pumps): accuracy ~1%

Pump + electronic flowmeter: accuracy ~0.5%

Weight & density measurementsDensity: accuracy 0.001 g/cm3 (can reach 0.0001 g/cm3)Weigth: accuracy <10 kg on ~12 tons.->volume ~0.1%

Page 6: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Full detector simulationPCC & APC, Kurchatov

Page 7: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Parameters used for the simulation

232 eV 102Δm 2

ΔmΔm0.20σ 2

0.02σabs 0.006σ rel 0.01σb2b

1.0σbkg

0.01Ratebkg

Reactor thermal power: 8.4 GWNear detector distance: 150 meters Volume N & F: 12.67 m3

Far detector distance: 1050 meters with PXE => 12.5 tonsNear detector efficiency: 32 % 50 % dead time x 80 % global load factor x 80 % detectionFar detector efficiency: 64 %No dead time x 80 % global load factor x 80 % detection

“Standard systematic errors”:

absolute relative backgrounds

1 par fit

or

with

Page 8: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Sensitivity at 90% C.L. if sin2(213)=0 versus integrated luminosity in RNU

σabs =2% σrel =0.6% σshape =2% σb2b =1%

Reactor 1 (2 RNU) Reactor 2 (40 RNU)

New target compositionincreases luminosity by 30 %

1 RNU = 200 t.GW.y

Page 9: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)

Support for the EDF power company to do a 2nd experiment @CHOOZDouble-CHOOZ sensitivity: sin2(213)<~0.03, 90% C.L. (m2 = 2.0 10-3 eV2)Current limint: CHOOZ : sin2(213)<0.2 discovery potential !

Technology / design well known (CHOOZ, BOREXINO, KamLAND, …) few R&D needed : Gd loading (stability) + material compatibility (Started, to be completed in half a year)

Proto-collaboration: PCC, Saclay, APC, TUM, MPIK, Tubingen, Kurchatov, Italy (likely to grow during the winter) (maxi-)letter of intent (February 2004) final proposal (6 months)

Experiment cost, Double-CHOOZ case: 2 x ~13 tons, preliminary detector cost <10 Meuros (Civil engineering not included)

Our Goal @Double- CHOOZ: Construction starts end of 2005 Start data taking in 2007-2008

Summary & outlook @Double-CHOOZ

2003 2004 2005 2006 2007 2008 2009Site Data takingProp. Construction ?design

< sin2(213) < ~0.04 < sin2(213) < 0.025-003Far detector starts

Page 10: Gd Liquid scintillator: completion of the R&D! Stability 0,1 % Gd in PXE LENS R&D  new metal β-diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months)