Dionex Corporation
Transcript of Dionex Corporation
EPA, ASTM, and Standard Methods Approved
i " 1 " * ^
t i *f ' , I ^ - i . ^ ^ .
F (1.5 ppm) α-Hydroxybutyrate Acetate Glycolate Butyrate Gluconate 23
7. a-Hydroxyvalerate 8. Formate (5 ppm) 9. Valerate
10. Pyruvate 1 1 . Monochloroacetate 12. B r O s -
13. C I - ( 3 ppm) 14. Galacturonate 15. N O z - ( 5 p p m ) 16. Glucuronate 17. Dichloroacetate 18. Trif luoroacetate
19. HPCb2" 20. Se032" 2 1 . B r ~ 22. N O s " 23. SÛ42" 24. Oxalate 25. Se042~ 26. a-Ketoglutarate 27. Fumarate 28. Phthalate 29. Oxalacetate 30. PO43
31.As04 3 " 32. CrU42
33. Citrate 34. Isocitrate 35. cis-Aconitate 36. trans-Aconitate
All anions 10 ppm unless noted
Gradient elution of anions. D ionex s e p a r a t i o n a n d de tec t i o n m e t h o d s h a v e d r a m a t i c a l l y i nc reased t h e reso l v i ng p o w e r of Ion C h r o m a t o g r a p h y . In t h i s e x a m p l e , an i ons w i t h vas t ly d i f f e ren t r e t e n t i o n cha rac te r i s t i c s w e r e de te r m i n e d in a s ing le r u n .
P P ™ 1.LÎ+ 2. Na +
NH.+ K+ Morpholine Cyclohexylamine IVlg2+
Sr2+
.5 2 3 3
30 10
1 2
10
Gradient elution of cations. For t h e f i r s t t i m e , m o n o -a n d d i v a l e n t m e t a l s a n d o rgan i c ca t i ons can be d e t e r m i n e d in a s ing le ana lys is . Th i s has been m a d e poss ib le by D ionex s u p p r e s s e d c o n d u c t i v i t y d e t e c t i o n a n d t h e n e w Dionex q u a r t e r n a r y g r a d i e n t c h r o m a t o g r a p h y p u m p .
WATER ANALYSIS Sample:
Industry:
Analytes:
Drinking, waste, ground, and rain water; soil and plant extracts
Environmental, agriculture, chemical
Inorganic ions, metals, and organics
Current method: Ion selective electrode, wet chemistry, t itration, AA
Problem: Current methods lack sensitivity and only determine one analy teatat ime
Solution: Dionex Ion Chromatography
No other Ion Chromatograph offers these advantages: Gradient elution, EPA, ASTM, and Standard Methods equivalency. And the capability to quickly determine trace anions or cations in aqueous samples, with little or no pretreatment.
Plus, with Dionex, you get the versatility you need to solve Ion Chromatography and HPLC analysis problems including carbamates, PAH's, organic acids, surfactants, sulfonates, transition metals, and amines — all with a single system. And at a reasonable cost.
If you're looking for a better solution, call us at (408) 737-0700. Chances are, we already have the answer.
DIONEX A BETTER SOLUTION
Dionex Corporation, P.O. Box 3603, Sunnyvale, CA 94088-3603. (408) 737-0700.
Canada Dionex Canada, Ltd., (416) 620-0077 England Dionex (UK) Ltd., (0252) 541346 West Germany Dionex G m b H , (06150) 3047 France Semsa S.A.. (1) 4621-6666 Italy Dionex S.r.l., (06) 5349735