Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide...

41
TIPP 2017 Beijing Commissioning and Initial Performance of the Belle II iTOP PID Subdetector Gary Varner University of Hawaii

Transcript of Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide...

Page 1: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Commissioning and Initial Performance of the Belle II iTOP PID

Subdetector Gary Varner

University of Hawaii

Page 2: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing TIPP 2017 Beijing

2.6m

1.2m

e-

8.0GeV e+

3.5GeV

Barrel PID Aerogel RICH

- PID (π/Κ) detectors - Inside current calorimeter - Use less material and allow more tracking volume Available geometry defines form factor

-

Upgrading PID Performance

2

Page 3: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing 3

Use wide bars like proposed TOP counter

Concept: Use best of both TOP (timing) and DIRC while fit in Belle PID envelope

• Use new, high-performance MCP-PMTs for sub-50ps single p.e. TTS • Use simultaneous T, θc [measured-predicted] for maximum K/π separation • Optimize pixel size

BaBar DIRC

imaging TOP (iTOP) NIM A623 (2010) 297-299.

Page 4: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

iTOP relativistic velocity

4

Beam Test Data These are cumulative distributions

• Space-time correlations

Page 5: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Actual PID is event-by-event • Test most probable distribution

5

Page 6: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Performance Requirements (TOP) • Single photon timing for MCP-PMTs

σ ~ 38.4ps

σ <~ 10ps (ideal waveform sampling)

NIM A602 (2009) 438

σ <~ 50ps target

To include T0, clock distrib, timebase ctrl

NOTE: this is single-photon timing, not event start-time “T0”

σT0 = 25ps

6

Page 7: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Mechanical constraints • A highly constrained space

7

Page 8: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Quartz optics

Bars: 1250 x 450 x 20 mm3 two bars per module Mirrors: 100 x 450 x 20 mm3 Prisms: 100 mm long, 456 x 20 mm2

at bar face expanding to 456 x 50 cm2 at MCPPMTs Material: Corning 7980

• DIN58927 class 0 material has no inclusions (inclusions ≤0.1 mm diameter are disregarded)

• Grade F (or superior) material having index homogeneity of ≤5 ppm over the clear aperture of the blank; verified at 632.8 nm

• Birefringence / Residual strain ≤1 nm/cm

8 DOE Review of Belle II Operations

Quartz: procurement, verification

Page 9: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Module production process Quartz gluing, Module Assembly

9 DOE Review of Belle II Operations

Page 10: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

iTOP Readout

64 FINESSE 16 COPPER

2x UT3 Trigger modules

8k channels 1k 8-ch. ASICs 64 “board stacks”

64 DAQ fiber transceivers

Clock, trigger, programming module (FTSW)

Waveform sampling ASIC

Low-jitter clock

64 SRM

8 FTSW

10

Page 11: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing 11

Readout Verification (pre-install, in-situ)

Single photon timing

< 100 ps

Event Time zero

Trigger time (single photon) Pulser

testing

< 50 ps

< 10 ns

Page 12: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Installation

12

Installation (very tight fit)

Page 13: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Installation completed…

13

Installation Complete (May 2016)

13

Page 14: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

Installation completed…

14

After installation – continued development

14

These studies used “raw waveform” readout; need Feature Extracted version (subsequent effort)

Page 15: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

TIPP 2017 Beijing

0, B-field Cosmic Ray Analysis

Artifact contribution (Need improved FW)

Further studies were defered for a couple months by PMT motion discovery (outcome of these studies)

Efficiency correction, artifact removal is tricky/difficult

15

Page 16: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

PMT Rotation Update (2 rotation issues)

16 Plan in place to replace ~50% of PMTs

Study of physics impact of decoupled PMTs (Modest effect)

Page 17: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Start-up Schedule/Commissioning

17

Integrate DAQ (now)

Global Cosmic Ray Run (with B-field)

Phase II startup (early 2018)

Trigger Development (refine)

30kHz L1 Buffer Mgmt (tuning)

Low amplitude Feature Extraction FE Tuning

Configuration / Command/Acquistion

Timing alignment

Global Commissioning

Page 18: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Timebase Calibration

18

• Took a while to get new FW release, SW work continued

Page 19: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Channel-by-channel Timing alignment

19

• Global timing alignment – laser studies

NO

TE

: Diff

eren

t Tim

e Sc

ales

!

Page 20: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Region Of Interest & Feature Extraction

Standard CFD algorithm works well, though performance degrades at low PMT (mandated to mitigate aging effects)

20

Reference pulse

Single p.e. laser pulses

Poised to take large data sets

Page 21: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Low PMT Gain Operation

Necessary to maximize MCP lifetime Studying how best to implement (Zynq: PS is too slow(?), PL option)

21

Significant improvement at low pulse heights

Page 22: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Summary

• Present: Production Firmware debugging DAQ integration and initial timing alignment

• Global Cosmic Ray Campaign: Detector alignment Magnetic field tracking

• First collisions (early 2018): Verify detector alignment Initial PID release

Belle II TOP Detector coming online

22

Page 23: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Back-up slides

23

Page 24: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

30kHz L1, high occupancy emulation 30kHz L1 trigger, 10 MHz background photons/PMT, multi-hit, multi-event buffering

24

At 400 SSTin Cycles (~19us per single photon hit), can run at 50kHz, so plenty of margin

Page 25: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Gain and Efficiency

25

Page 26: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

PMT Replacement

26

“1x BG”

Page 27: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

PERFORMANCE SUMMARIES

27

Page 28: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Note: CAMAC TDC and phototube TTS contributions included: actual resolution is better

Single photon timing

• All installed channels • 1 entry per channel

• Limited statistics

28

Page 29: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Hawaii Tested

U. South Carolina Tested (higher noise)

Obj Thresh

Verification: Event Time Zero

29

Page 30: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Verification: Event Trigger Time

Trigger time resolution [ns]

Note: Using coarser AXI clock during production testing. 4x faster clock (expect 4x improved resolution) in final trigger firmware [not yet ready]

30

Page 31: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Hit maps from in-situ cosmic ray tests

September 5, 2016 31

Yes – voltage turned down

Page 32: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

IRSX ASIC Overview

• 8 channels per chip @ 2.8 GSa/s • Samples stored, 12-bit digitized in groups of 64 • 32k samples per channel (11.6us at 2.8GSa/s) • Compact ASICs implementation:

Trigger comparator and thresholding on chip On chip ADC Multi-hit buffering

Die Photograph

~8m

m

32

Page 33: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Laser Calibration steps

1. Pedestal subtract 2. Correct Amplitude dependence 3. Run dT Minimizer, obtain results 4. Apply dT values All binned, so easily implemented at Look-up tables

on the SCROD FPGA

• Both gain/efficiency and timing data taken at same time • About 8 hours per 128 channel board stack

33

Page 34: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

1. Ped subtract & 50% CFD

Default samples are ~ 0.37ns/point Determine timing from interpolation

Before pedestal subtraction

Measure peak to determine 50% threshold

34

Page 35: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

1. After 50% CFD algorithm

No corrections applied TDC assumed exactly 25ps/lsb TDC INL not considered

Kinematic p.e. recoil tail

35

Page 36: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

2. Voltage dependence

36

Page 37: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

2. Improved Residual

37

Page 38: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

2. TDC resolution residual

Differential and Integral non-linearity in sampling timebase (expected for these types of Switched Capacitor Array ASICs)

38

Page 39: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

3. After Autocalibration

Compare with previous slide – timebase uniform and absolute timing calibrated (clock period closure constraint)

39

Page 40: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Output After “dT minimizer” algorithm

Time between pulses in agreement, No matter where look in the window

Absolute timebase cross-calibrated With respect to SSTin clock period

40

Page 41: Commissioning and Initial Performance of the Belle II iTOP PID … · 2017. 5. 25. · Use wide bars like proposed TOP counter . Concept: Use best of both TOP (timing) and DIRC while

Production single photon testing

Use SSTin period constraint to calibrate absolute timebase

~31ps TDC+phase SL-10 TTS ~35ps IRSX electronics:

~33ps

41