APPLICATIONS TECHNICAL FEATURES · Accuracy: According to IEC 60770 2 Power supply: 9...36 V DC...

1

Click here to load reader

Transcript of APPLICATIONS TECHNICAL FEATURES · Accuracy: According to IEC 60770 2 Power supply: 9...36 V DC...

Page 1: APPLICATIONS TECHNICAL FEATURES · Accuracy: According to IEC 60770 2 Power supply: 9...36 V DC Load: Rmax = [(Vs - Vs min) / 0.02] Ω Temperature compensation: 0...85 °C

09-10-2014 591 I1 02 A

- Connection in PVDF 1”1/2

- Measuring cell: ceramic (96%)

- Accuracy: 0.35% (FSO IEC 60770)

- Ranges from 0…60 mbar to 0…1 bar

- Designed for aggressive fluids

APPLICATIONS

BAMONIV is designed for measuring level of aggressive fluids. The wetted

parts are made of PVDF and FPM, the highly accurate sensor is of ceramic

(Al2O3 96%). BAMONIV is convenient on dirty and viscous fluids. Well

introduced in pharmaceutical and all chemical industries.

TECHNICAL FEATURES

Measuring ranges: 0 to 0,06 / …to 1 bar (detailed table below)

Output signal: 4...20 mA - 2 wire technique

Measuring cell: Ceramic Al2O3 96 %

Fitting: PVDF, 1”1/2 MG - DIN 3852

Housing: AISI 303 (1.4305)

Seal: FPM

Connector: ISO 4400 or cable output (2 m long)

Long term stability: ≤ ±0.1 % F.S. / year

Accuracy: According to IEC 60770 2

Power supply: 9...36 V DC

Load: Rmax = [(Vs - Vs min) / 0.02] Ω

Temperature compensation: 0...85 °C

Temperature incidence: ± 0.1 % F.S. / 10 K

Response time: ≤ 0.2 second

Emissions & Interferences: According to EN 61326

Electrical protections: Against reversed polarity, over ride, short circuit

Temperature limits Storage: -40...+100 °C

Average: -30...+100 °C

Ambient: -25...+85 °C

Mass: 0.2 kg

Mounting: Any position

ORDERING CODE

BAMONIV 591

Output:Connector ISO 4400 4Cable output 5

Range: /m WC0.6 011 021.6 032.5 044 056 0610 07

591

HYDROSTATIC LEVEL TRANSMITTER

BAMONIV

Hydrostatic level transmitter

BAMONIV

NIV

591-02/1

ISO 4400 connector

Cable output