Α-Θ WI9-14ME

download Α-Θ WI9-14ME

of 36

description

α-θ w19-14me

Transcript of Α-Θ WI9-14ME

  • Wasser/Wasser-Wrmepumpe fr Innenaufstellung

    WI 9 MEWI 14 ME

    Water-to-Water Heat Pump for Indoor Installation

    Pompe chaleur eau-eau pour installation intrieure

    Montage- und Gebrauchsanweisung De

    utsc

    hEn

    glis

    hFr

    ana

    isInstructions dinstallation et dutilisation

    Installation andOperating Instructions

    Bestell-Nr. / Order no. / No de commande : 452232.66.17 FD 8612

  • www.dimplex.de D-1

    Deu

    tsch

    Inhaltsverzeichnis1 Bitte sofort lesen .......................................................................................................................... D-2

    1.1 Wichtige Hinweise ..................................................................................................................................D-21.2 Gesetzliche Vorschriften und Richtlinien ................................................................................................D-21.3 Energiesparende Handhabung der Wrmepumpe .................................................................................D-2

    2 Verwendungszweck der Wrmepumpe...................................................................................... D-22.1 Anwendungsbereich ...............................................................................................................................D-22.2 Arbeitsweise ...........................................................................................................................................D-2

    3 Grundgert.................................................................................................................................... D-3

    4 Transport....................................................................................................................................... D-3

    5 Aufstellung.................................................................................................................................... D-45.1 Allgemeine Hinweise ..............................................................................................................................D-45.2 Schallemissionen....................................................................................................................................D-4

    6 Montage......................................................................................................................................... D-46.1 Allgemein ................................................................................................................................................D-46.2 Heizungsseitiger Anschluss....................................................................................................................D-46.3 Wrmequellenseitiger Anschluss............................................................................................................D-46.4 Elektrischer Anschluss............................................................................................................................D-5

    7 Inbetriebnahme............................................................................................................................. D-57.1 Allgemein ................................................................................................................................................D-57.2 Vorbereitung ...........................................................................................................................................D-57.3 Vorgehensweise bei Inbetriebnahme .....................................................................................................D-5

    8 Pflege / Reinigung ........................................................................................................................ D-68.1 Pflege......................................................................................................................................................D-68.2 Reinigung Heizungsseite ........................................................................................................................D-68.3 Reinigung Wrmequellenseite................................................................................................................D-68.4 Anforderungen an die Wasserqualitt ....................................................................................................D-6

    9 Strungen / Fehlersuche ............................................................................................................. D-6

    10 Auerbetriebnahme / Entsorgung .............................................................................................. D-6

    11 Gerteinformation ........................................................................................................................ D-7

    12 Garantieurkunde........................................................................................................................... D-8

    Anhang / Appendix / Annexes ............................................................................................................ A-I

  • Deutsch

    11 Bitte sofort lesen

    1.1 Wichtige Hinweise

    ACHTUNG!Das Brunnenwasser muss der geforderten Wasserqualitt entsprechen.

    ACHTUNG!Die Wrmepumpe ist nicht am Holzrost befestigt.

    ACHTUNG!Die Wrmepumpe darf nur bis zu einer Neigung von maximal 45 (in jederRichtung) gekippt werden.

    ACHTUNG!Gert nicht an den Bohrungen in den Verkleidungsblechen anheben!

    ACHTUNG!Vor Anschluss der Wrmepumpe Heizungsanlage splen.

    ACHTUNG!Die Inbetriebnahme der Wrmepumpe muss gem der Montage- undGebrauchsanweisung des Wrmepumpenreglers erfolgen.

    ACHTUNG!Zur Vermeidung von Ablagerungen (z.B. Rost) im Kondensator derWrmepumpe wird empfohlen, ein geeignetes Korrosionsschutzsystemeinzusetzen.

    ACHTUNG!Arbeiten an der Wrmepumpe drfen nur vom autorisierten undsachkundigen Kundendienst durchgefhrt werden.

    ACHTUNG!Vor ffnen des Gertes sind alle Stromkreise spannungsfrei zu schalten.

    1.2 Gesetzliche Vorschriften und Richtlinien

    Die Wrmepumpe entspricht allen relevanten DIN-/VDE-Vor-schriften und EG-Richtlinien. Diese knnen der CE-Erklrung imAnhang entnommen werden.Der elektrische Anschluss der Wrmepumpe muss nach den gl-tigen VDE-, EN- und IEC-Normen ausgefhrt werden. Auerdemsind die Anschlussbedingungen der Versorgungsunternehmenzu beachten.Die Wrmepumpe ist entsprechend den einschlgigen Vorschrif-ten in die Wrmequellen- und Heizungsanlage einzubinden.Personen, insbesondere Kinder, die aufgrund ihrer physischen,sensorischen oder geistigen Fhigkeiten oder ihrer Unerfahren-heit oder Unkenntnis nicht in der Lage sind, das Gert sicher zubenutzen, sollten dieses Gert nicht ohne Aufsicht oder Anwei-sung durch eine verantwortliche Person benutzen.Kinder sollten beaufsichtigt werden, um sicher zu stellen, dasssie nicht mit dem Gert spielen.

    1.3 Energiesparende Handhabung der Wrmepumpe

    Durch das Betreiben dieser Wrmepumpe tragen Sie zur Scho-nung unserer Umwelt bei. Fr den effizienten Betrieb ist einesorgfltige Bemessung der Heizungsanlage und der Wrme-quelle sehr wichtig. Dabei ist besonderes Augenmerk auf mg-lichst niedrige Wasservorlauftemperaturen zu richten. Darumsollten alle angeschlossenen Energieverbraucher fr niedrigeVorlauftemperaturen geeignet sein. Eine um 1 K hhere Heiz-wassertemperatur steigert den Energieverbrauch um ca. 2,5%.Eine Niedertemperaturheizung mit Vorlauftemperaturen zwi-schen 30 C und 50 C ist fr einen energiesparenden Betriebgut geeignet.

    2 Verwendungszweck der Wrmepumpe

    2.1 AnwendungsbereichDie Wasser/Wasser-Wrmepumpe kann in vorhandene oderneu zu errichtende Heizungsanlagen eingesetzt werden. AlsWrmetrger dient Wasser. Dieses kann aus Brunnen oder hn-lichen Anlagen zugefhrt werden.Um Korrosionsrisiken am Verdampfer auszuschlieen, mussdas Brunnenwasser auf die Korrosionswahrscheinlichkeit vonmetallischen Werkstoffen nach der DIN 50930 bewertet werden.Einzelheiten dazu sind im Projektierungs- und Installationshand-buch fr Heizungswrmepumpen zu finden.

    ACHTUNG!Das Brunnenwasser muss der geforderten Wasserqualitt entsprechen.

    2.2 ArbeitsweiseEine Brunnenpumpe frdert das Wasser in den Verdampfer derWrmepumpe. Dort gibt es Wrme an das Kltemittel im Klte-kreislauf ab.Das Kltemittel wird vom elektrisch angetriebenen Verdichter an-gesaugt, verdichtet und auf ein hheres Temperaturniveau "ge-pumpt". Die bei diesem Vorgang zugefhrte elektrische Antriebs-leistung geht nicht verloren, sondern wird grtenteils ebenfallsdem Kltemittel zugefhrt.Daraufhin gelangt das Kltemittel in den Verflssiger und ber-trgt hier wiederum seine Wrmeenergie an das Heizwasser.Abhngig vom Betriebspunkt erwrmt sich so das Heizwasserauf bis zu 60 C.D-2

  • Deu

    tsch

    43 GrundgertDas Grundgert besteht aus einer anschlussfertigen Wrme-pumpe fr Innenaufstellung mit Gehuse, Schaltraum und inte-griertem Regler. Im Kltekreis ist das Kltemittel R407C einge-fllt. Das Kltemittel ist FCKW-frei, baut kein Ozon ab und istnicht brennbar. Im Schaltraum sind alle fr den Betrieb der Wrmepumpe not-wendigen Bauteile eingebaut. Ein Fhler fr die Auenwandtem-peratur mit Befestigungsmaterial sowie ein Schmutzfnger lie-gen der Wrmepumpe bei. Die Spannungszufhrung fr Last-und Steuerstrom ist bauseits zu verlegen.Die Zuleitung der bauseits zu stellenden Brunnenpumpe ist imSchaltraum anzuschlieen. Dabei ist zu berprfen ob derwerkseitig eingebaute Motorschutz fr die bauseits eingebautePumpe ausreichend ist.

    1) Verdampfer2) Schaltraum3) Verflssiger4) Verdichter

    4 TransportZum Transport auf ebenem Untergrund eignet sich ein Hubwa-gen. Muss die Wrmepumpe auf unebenem Untergrund oderber Treppen befrdert werden, kann dies mit Tragriemen ge-schehen. Diese knnen direkt unter dem Holzrost hindurchge-fhrt werden.

    ACHTUNG!Die Wrmepumpe ist nicht am Holzrost befestigt.

    ACHTUNG!Die Wrmepumpe darf nur bis zu einer Neigung von maximal 45 (in jederRichtung) gekippt werden.

    Zum Anheben des Gertes ohne Palette sind die seitlich im Rah-men vorgesehenen Bohrungen zu benutzen. Die seitlichen Ver-kleidungsbleche sind dabei abzunehmen. Als Tragehilfe kannein handelsbliches Rohr dienen.

    ACHTUNG!Gert nicht an den Bohrungen in den Verkleidungsblechen anheben!

    www.dimplex.de D-3

  • Deutsch

    55 Aufstellung

    5.1 Allgemeine HinweiseDas Gert ist nur in nicht feuchten Innenrumen auf einer ebe-nen, glatten und waagrechten Flche aufzustellen. Dabei sollteder Rahmen rundum dicht am Boden anliegen, um eine geeig-nete Schallabdichtung zu gewhrleisten. Ist dies nicht der Fall,knnen zustzliche schalldmmende Manahmen notwendigwerden.Die Wrmepumpe muss so aufgestellt sein, dass ein Kunden-diensteinsatz problemlos durchgefhrt werden kann. Dies ist ge-whrleistet, wenn ein Abstand von ca. 1 m vor und neben derWrmepumpe eingehalten wird.

    5.2 SchallemissionenAufgrund der Schallisolation arbeitet die Wrmepumpe sehrleise. Um eine Schwingungsbertragung auf das Fundament zuverhindern, sollte eine geeignete, dmpfende Gummimatte unterden Grundrahmen der Wrmepumpe gelegt werden.Um die bertragung von Geruschen in das Heizsystem zu ver-meiden, empfiehlt es sich, die Wrmepumpe mit Schlauchst-cken an das Heizsystem zu koppeln.

    6 Montage

    6.1 AllgemeinAn der Wrmepumpe sind folgende Anschlsse herzustellen: Vor-/Rcklauf Brunnenanlage Vor-/Rcklauf Heizung Stromversorgung

    6.2 Heizungsseitiger Anschluss

    ACHTUNG!Vor Anschluss der Wrmepumpe Heizungsanlage splen.

    Bevor die heizwasserseitigen Anschlsse der Wrmepumpe er-folgen, muss die Heizungsanlage gesplt werden, um eventuellvorhandene Verunreinigungen, Reste von Dichtmaterial oderhnliches, zu entfernen. Ein Ansammeln von Rckstnden imVerflssiger kann zum Totalausfall der Wrmepumpe fhren.Nach erstellter heizungsseitiger Installation ist die Heizungsan-lage zu fllen, zu entlften und abzudrcken.

    MindestheizwasserdurchsatzDer Mindestheizwasserdurchsatz der Wrmepumpe ist in jedemBetriebszustand der Heizungsanlage sicherzustellen. Dieseskann z.B. durch Installation eines differenzdrucklosen Verteilersoder eines berstrmventiles erreicht werden. Die Einstellungeines berstrmventiles ist in Kapitel Inbetriebnahme erklrt.

    Frostschutz bei frostgefhrdeter AufstellungSofern Regler und Heizungsumwlzpumpen betriebsbereit sind,arbeitet die Frostschutzfunktion des Reglers. Bei Auerbetrieb-nahme der Wrmepumpe oder Stromausfall ist die Anlage zuentleeren. Bei Wrmepumpenanlagen, an denen ein Stromaus-fall nicht erkannt werden kann (Ferienhaus), ist der Heizungs-kreis mit seinem geeigneten Frostschutz zu betreiben.

    6.3 Wrmequellenseitiger Anschluss

    Folgende Vorgehensweise ist beim Anschluss einzuhalten:Die Brunnenleitungen am Vor- und Rcklauf der Wrmepumpeanschlieen.

    ACHTUNG!Das Brunnenwasser muss der geforderten Wasserqualitt entsprechen.

    Dabei ist das hydraulische Prinzipschema zu beachten.D-4

  • Deu

    tsch

    7.36.4 Elektrischer AnschlussAn der Wrmepumpe mssen folgende elektrischen Anschlssehergestellt werden. Anschluss der Steuerleitung am Schaltblech der Wrme-

    pumpe ber Klemmen X1: L/N/PE. Anschluss der Lastleitung am Schaltblech der Wrme-

    pumpe ber Klemmen X5: L/N/PE. Anschluss der Lastleitung Brunnenpumpe am Schaltblech

    der Wrmepumpe ber Klemme X5: L1/N1/PE. Anschluss der Brunnenpumpe (bauseitig) am Schaltblech

    der Wrmepumpe ber Klemme X1: PE und PumpenschtzK5: 14/24.

    Beim Anschluss der Lastleitung Brunnenpumpe muss gewhr-leistet sein, dass die Spannungsversorgung fr diese Klemmennicht vom Tarifschtz abgeschaltet werden kann, um die Ab-schaltverzgerung der Brunnenpumpe zu gewhrleisten.Alle fr den Betrieb der Wrmepumpe notwendigen elektrischenBauteile befinden sich am Schaltblech.Genaue Anweisungen ber Anschluss und Funktion des Wrme-pumpenreglers (z.B. beiliegender Auenwandfhler) entnehmenSie bitte der beigefgten Gebrauchsanweisung des Reglers.Eine Abschaltung mit mindestens 3 mm Kontaktffnungsabstand(z.B. EVU-Sperrschtz oder Leistungsschtz), sowie ein 1-pol.Sicherungsautomat sind vorzusehen. Der bentigte Leiterquer-schnitt ist gem der Leistungsaufnahme der Wrmepumpe, dertechnischen Anschlussbedingungen des jeweiligen EVU undnach den einschlgigen Vorschriften zu whlen. Die Leistungs-aufnahme der Wrmepumpe entnehmen Sie der Produktinfor-mation oder dem Typschild. Die Anschlussklemmen sind frmax. 10 mm2 Leiterquerschnitt ausgelegt.

    7 Inbetriebnahme

    7.1 AllgemeinUm eine ordnungsgeme Inbetriebnahme zu gewhrleisten,sollte diese von einem vom Werk autorisierten Kundendienstdurchgefhrt werden. Unter bestimmten Bedingungen ist damiteine Verlngerung der Gewhrleistung verbunden (vgl. Garan-tieleistungen).

    7.2 VorbereitungVor der Inbetriebnahme mssen folgende Punkte geprft wer-den: Alle Anschlsse der Wrmepumpe mssen, wie in Kapitel 6

    beschrieben, montiert sein. Die Wrmequellenanlage und der Heizkreis mssen gefllt

    und geprft sein. Im Brunnen- und Heizkreislauf mssen alle Schieber, die

    den korrekten Fluss behindern knnten, geffnet sein. Der Wrmepumpenregler muss gem seiner Gebrauchs-

    anweisung auf die Heizungsanlage abgestimmt sein.

    7.3 Vorgehensweise bei Inbetriebnahme

    Die Inbetriebnahme der Wrmepumpe erfolgt ber den Wrme-pumpenregler.

    ACHTUNG!Die Inbetriebnahme der Wrmepumpe muss gem der Montage- undGebrauchsanweisung des Wrmepumpenreglers erfolgen.

    Wird der Mindestheizwasserdurchsatz mittels berstrmventilsichergestellt, so ist dieses auf die Heizungsanlage abzustim-men. Eine falsche Einstellung kann zu verschiedenen Fehlerbil-dern und einem erhhten elektrischen Energiebedarf fhren. Umdas berstrmventil richtig einzustellen, empfehlen wir folgendeVorgehensweise:Schlieen Sie alle Heizkreise, die auch im Betrieb je nach Nut-zung geschlossen sein knnen, so dass der vom Wasserdurch-satz ungnstigste Betriebszustand vorliegt. Dies sind in derRegel die Heizkreise der Rume auf der Sd- und Westseite.Mindestens ein Heizkreis muss geffnet bleiben (z.B. Bad).Das berstrmventil ist so weit zu ffnen, dass sich bei der aktu-ellen Wrmequellentemperatur die in der nachfolgend stehen-den Tabelle angegebene maximale Temperaturspreizung zwi-schen Heizungsvor- und Rcklauf ergibt. DieTemperaturspreizung ist mglichst nahe an der Wrmepumpezu messen. Bei monoenergetischen Anlagen ist der Heizstab zudeaktivieren.

    Strungen whrend des Betriebes werden am Wrmepumpen-regler angezeigt und knnen, wie in der Gebrauchsanweisungdes Wrmepumpenreglers beschrieben ist, behoben werden.

    Wrmequellen-temperatur

    max. Temperaturspreizung zwischen Heizungsvor- und

    Rcklaufvon bis7 C 12 C 10 K

    13 C 18 C 11 K

    19 C 25 C 12 Kwww.dimplex.de D-5

  • Deutsch

    88 Pflege / Reinigung

    8.1 PflegeDie Wrmepumpe arbeitet wartungsfrei. Um Betriebsstrungendurch Schmutzablagerungen in den Wrmeaustauschern zu ver-meiden, ist dafr Sorge zu tragen, dass keinerlei Verschmutzun-gen in die Wrmequellen- und Heizungsanlage gelangen kn-nen. Sollte es dennoch zu derartigen Betriebsstrungenkommen, ist die Anlage wie unten angegeben zu reinigen.

    8.2 Reinigung HeizungsseiteSauerstoff kann im Heizwasserkreis, insbesondere bei Verwen-dung von Stahlkomponenten, Oxidationsprodukte (Rost) bilden.Dieser gelangt ber Ventile, Umwlzpumpen oder Kunststoff-rohre in das Heizsystem. Deshalb sollte besonders bei denRohren der Fubodenheizung auf eine diffusionsdichte Instal-lation geachtet werden.

    ACHTUNG!Zur Vermeidung von Ablagerungen (z.B. Rost) im Kondensator derWrmepumpe wird empfohlen, ein geeignetes Korrosionsschutzsystemeinzusetzen.

    Auch Reste von Schmier- und Dichtmitteln knnen das Heizwas-ser verschmutzen.Sind die Verschmutzungen so stark, dass sich die Leistungsf-higkeit des Verflssigers in der Wrmepumpe verringert, mussein Installateur die Anlage reinigen.Nach heutigem Kenntnisstand schlagen wir vor, die Reinigungmit einer 5%-igen Phosphorsure oder, falls hufiger gereinigtwerden muss, mit einer 5%-igen Ameisensure durchzufhren. In beiden Fllen sollte die Reinigungsflssigkeit Raumtempera-tur haben. Es ist empfehlenswert, den Wrmeaustauscher ent-gegen der normalen Durchflussrichtung zu splen.Um zu verhindern, dass surehaltiges Reinigungsmittel in denHeizungsanlagenkreislauf gelangt, empfehlen wir, das Splgertdirekt an den Vor- und Rcklauf des Verflssigers anzuschlie-en. Danach muss mit geeigneten neutralisierenden Mittelngrndlich nachgesplt werden, um Beschdigungen durch even-tuell im System verbliebene Reinigungsmittelreste zu verhin-dern.Die Suren sind mit Vorsicht anzuwenden und es sind die Vor-schriften der Berufsgenossenschaften einzuhalten.Im Zweifelsfall ist mit dem Hersteller des ReinigungsmittelsRcksprache zu halten!

    8.3 Reinigung WrmequellenseiteIm Wrmequelleneintritt der Wrmepumpe ist ein Schmutzfn-ger montiert, um den Verdampfer gegen Verunreinigungen zuschtzen. Anfangs sollte das Filtersieb des Schmutzfngers inrelativ kurzen Abstnden gereinigt werden. Sind weniger Verun-reinigungen erkennbar, kann der Zeitabstand entsprechend ver-lngert werden.

    8.4 Anforderungen an die Wasserqualitt

    Um eine Verockerung der Wrmepumpenanlage zu verhindern,drfen keine absetzbaren Stoffe im Grundwasser enthalten seinund die EISEN- (< 0,2 mg/l) und MANGAN- (< 0,1 mg/l) Grenz-werte mssen eingehalten werden.Der Einsatz von Oberflchenwasser oder salzhaltigen Gews-sern ist nicht erlaubt. Erste Hinweise ber eine mgliche Nut-zung des Grundwassers knnen bei den rtlichen Wasserversor-gungsunternehmen erfragt werden. Wasseranalysen werdendurch wassertechnische Labore erstellt.Eine Wasseranalyse bezglich Korrosion des Verdampfers istnicht erforderlich, wenn die Grundwassertemperatur im Jahres-mittel nicht ber 13 C liegt. In diesem Fall mssen nur die Grenzwerte fr Eisenund Mangan eingehalten werden (Verockerung).

    9 Strungen / FehlersucheDiese Wrmepumpe ist ein Qualittsprodukt und sollte strungs-frei arbeiten. Tritt dennoch eine Strung auf, wird dies im Displaydes Wrmepumpenamanagers angezeigt. Schlagen Sie dazuauf der Seite Strungen und Fehlersuche in der Gebrauchsan-weisung des Wrmepumpenreglers nach.Wenn die Strung nicht selbst behoben werden kann, verstndi-gen Sie bitte den zustndigen Kundendienst.

    ACHTUNG!Arbeiten an der Wrmepumpe drfen nur vom autorisierten undsachkundigen Kundendienst durchgefhrt werden.

    ACHTUNG!Vor ffnen des Gertes sind alle Stromkreise spannungsfrei zu schalten.

    10 Auerbetriebnahme / Entsorgung

    Bevor die Wrmepumpe ausgebaut wird, ist die Maschine span-nungsfrei zu schalten und abzuschiebern. Umweltrelevante An-forderungen, in Bezug auf Rckgewinnung, Wiederverwendungund Entsorgung von Betriebsstoffen und Bauteilen gem dengngigen Normen, sind einzuhalten. Dabei ist besonders Wertauf eine fachgerechte Entsorgung des Kltemittels und Klteleszu legen.D-6

  • Deu

    tsch

    1111 Gerteinformation1 Typ- und Verkaufsbezeichnung WI 9ME WI 14ME2 Bauform2.1 Schutzart nach EN 60 529 IP 20 IP 20

    2.2 Aufstellungsort Innen Innen

    3 Leistungsangaben EN 255 EN14511 EN 255 EN145113.1 Temperatur-Betriebseinsatzgrenzen:

    Heizwasser-Vorlauf C bis 55 bis 55

    Kaltwasser (Wrmequelle) C +7 bis +25 +7 bis +25

    3.2 Heizwasser-Temperaturspreizung bei W10 / W35 K 9,5 5,0 8,8 5,0

    3.3 Wrmeleistung / Leistungszahl bei W7 / W55 1 kW / ---

    1. Diese Angaben charakterisieren die Gre und die Leistungsfhigkeit der Anlage. Fr wirtschaftliche und energetische Betrachtungen sind Bivalenzpunkt und Regelung zu be-rcksichtigen. Dabei bedeuten z.B. W10 / W55: Wrmequellentemperatur 10 C und Heizwasser-Vorlauftemperatur 55 C.

    6,9 / 2,5 12,2 / 2,3

    bei W10 / W50 1 kW / --- 7,7 / 3,2 13,4 / 3,4

    bei W10 / W45 1 kW / --- 7,7 / 3,7 13,4 / 3,8

    bei W10 / W35 1 kW / --- 8,3 / 5,1 8,2 / 4,8 13,6 / 5,0 13,5 / 4,7

    3.4 Heizwasserdurchfluss bei interner Druckdifferenz m/h / Pa 0,75 / 7000 1,4 / 24000 1,3 / 7000 2,3 / 22000

    3.5 Kaltwasserdurchsatz bei interner Druckdifferenz(Wrmequelle) m/h / Pa 2,0 / 6200 3,3 / 19000

    3.6 Kltemittel; Gesamt-Fllgewicht Typ / kg R407C / 1,7 R407C / 1,9

    4 Abmessungen, Anschlsse und Gewicht4.1 Gerteabmessungen ohne Anschlsse 2 H x B x L mm

    2. Beachten Sie, dass der Platzbedarf fr Rohranschluss, Bedienung und Wartung grer ist.

    1445 x 650 x 575 1445 x 650 x 575

    4.2 Gerteanschlsse fr Heizung Zoll G 1" a G 1" a

    4.3 Gerteanschlsse fr Wrmequelle Zoll G 1" a G 1" a

    4.4 Gewicht der Transporteinheit(en) incl. Verpackung kg 156 165

    5 Elektrischer Anschluss5.1 Nennspannung; Absicherung V / A 230 / 16 230 / 25

    5.2 Nennaufnahme 1 W10 W35 kW 1,62 1,69 2,72 2,87

    5.3 Anlaufstrom m. Sanftanlasser A 26 45

    5.4 Nennstrom W10 W35 / cos A / --- 8,0 9,18 14,8 16,66 Entspricht den europischen Sicherheitsbestimmungen 3

    3. siehe CE-Konformittserklrung

    3

    7 Sonstige Ausfhrungsmerkmale7.1 Wasser im Gert gegen Einfrieren geschtzt 4

    4. Die Heizungs-Umwlzpumpe und der Regler der Wrmepumpe mssen immer betriebsbereit sein.

    ja ja

    7.2 Leistungsstufen 1 1

    7.3 Regler intern / extern intern internwww.dimplex.de D-7

  • D-8

    Deutsch

    12

    12 GarantieurkundeDie nachstehenden Bedingungen, die Voraussetzungen undUmfang unserer Garantieleistung umschreiben, lassen die Ge-whrleistungsverpflichtungen des Verkufers aus dem Kaufver-trag mit dem Endabnehmer unberhrt. Fr die Gerte leisten wirGarantie gem nachstehenden Bedingungen:Wir beheben unentgeltlich nach Magabe der folgenden Bedin-gungen Mngel am Gert, die nachweislich auf einem Material-und/oder Herstellungsfehler beruhen, wenn sie uns unverzglichnach Feststellung und innerhalb von 24 Monaten nach Lieferungan den Erstendabnehmer gemeldet werden. Bei gewerblichemGebrauch innerhalb von 12 Monaten. Zeigt sich der Mangel in-nerhalb von 6 Monaten ab Lieferung und liegt eine erfolgreicheInbetriebnahme (Heizungs-Wrmepumpe und zentrale Woh-nungslftungsgerte) durch den autorisierten Systemtechnik-Kundendienst vor, wird vermutet, dass es sich um einen Mate-rial- oder Herstellungsfehler handelt.Dieses Gert fllt nur dann unter diese Garantie, wenn es voneinem Unternehmer in einem der Mitgliedstaaten der Eur-opischen Union gekauft wurde, es bei Auftreten des Mangels inDeutschland betrieben wird und Garantieleistungen auch inDeutschland erbracht werden knnen.Die Behebung der von uns als garantiepflichtig anerkannterMngel geschieht dadurch, dass die mangelhaften Teile unent-geltlich nach unserer Wahl instandgesetzt oder durch einwand-freie Teile ersetzt werden. Durch Art oder Ort des Einsatzes desGertes oder schlechte Zugnglichkeit des Gertes bedingte au-ergewhnliche Kosten der Mngelbeseitigung werden nichtbernommen. Der freie Gertezugang muss durch den Endab-nehmer gestellt werden. Ausgebaute Teile, die wir zurckneh-men, gehen in unser Eigentum ber. Die Garantiezeit fr Nach-besserungen und Ersatzteile endet mit dem Ablauf derursprnglichen Garantiezeit fr das Gert. Die Garantie erstrecktsich nicht auf leicht zerbrechliche Teile, die den Wert oder dieGebrauchstauglichkeit des Gertes nur unwesentlich beein-trchtigen. Es ist jeweils der Original-Kaufbeleg mit Kauf- und/oder Lieferdatum vorzulegen.Eine Garantieleistung entfllt, wenn vom Endabnehmer odereinem Dritten die entsprechenden VDE-Vorschriften, die Bestim-mungen der rtlichen Versorgungsunternehmen oder unsereMontage- und Gebrauchsanweisung sowie die in den Projektie-rungsunterlagen enthaltenen Hinweise oder Einbindungssche-men nicht beachtet worden sind oder wenn unser funktionsnot-wendiges Zubehr nicht eingesetzt wurde. Durch etwa seitensdes Endabnehmers oder Dritter unsachgem vorgenommenennderungen und Arbeiten, wird die Haftung fr die daraus ent-stehenden Folgen aufgehoben. Die Garantie erstreckt sich aufdas Gert und vom Lieferer bezogene Teile. Nicht vom Liefererbezogene Teile und Gerte-/Anlagenmngel die auf nicht vomLieferer bezogene Teile zurckzufhren sind fallen nicht unterden Garantieanspruch.Sofern der Mangel nicht beseitigt werden kann, oder die Nach-besserung von uns abgelehnt oder unzumutbar verzgert wird,wird der Hersteller entweder kostenfreien Ersatz liefern oder denMinderwert vergten. Im Falle einer Ersatzlieferung, behalten wiruns die Geltendmachung einer angemessenen Nutzungsanrech-nung, fr die bisherige Nutzungszeit, vor. Weitergehende oderandere Ansprche, insbesondere solche auf Ersatz auerhalbdes Gertes entstandener Schden sind soweit eine Haftungnicht zwingend gesetzlich angeordnet ist ausgeschlossen. Beieiner Haftung nach 478 BGB wird die Haftung des Lieferers aufdie Servicepauschalen des Lieferers als Hchstbetrag be-schrnkt.

    Eine Verlngerung der Garantie auf 36 Monate fr Heizungs-Wrmepumpen und zentrale Wohnungslftungsgerte ab Inbe-triebnahmedatum, jedoch maximal 38 Monate ab AuslieferungWerk, wird gem den nachfolgenden Bedingungen gewhrt:Voraussetzung fr die bernahme der verlngerten Garantie isteine kostenpflichtige Inbetriebnahme durch den autorisiertenSystemtechnik-Kundendienst mit Inbetriebnahmeprotokoll inner-halb einer Betriebszeit (Verdichterlaufzeit) von weniger als 150Stunden. Im Inbetriebnahmeprotokoll vermerkte Mngel sind un-verzglich zu beseitigen. Dies ist Grundlage fr die Garantie.Das Inbetriebnahmeprotokoll ist, innerhalb von einem Monatnach erfolgter Inbetriebnahme, an die unten angegebeneAdresse einzureichen, von welcher auch die Garantiezeitver-lngerung besttigt wird.Die Inbetriebnahmepauschale beinhaltet die eigentliche Inbe-triebnahme und die Fahrtkosten. Es wird keine Haftung fr dieordnungsgeme Planung, Dimensionierung und Ausfhrungder Gesamtanlage bernommen. Die Behebung von Anlagen-mngel und Wartezeiten sind Sonderleistungen.Die Inbetriebnahmepauschale fr alle Heizungs-Wrmepumpenvon derzeit netto Euro 340,-- und fr zentrale Lftungsanlagenvon netto Euro 400,--, jeweils je Gert, wird durch den autorisier-ten Systemtechnik-Kundendienst dem Auftraggeber in Rech-nung gestellt. Eine Preisanpassung ist vorbehalten.Im Kundendienstfalle wird der autorisierte Systemtechnik-Kun-dendienst vor Ort informiert, der fr eine schnelle Abhilfe desProblems sorgt. Den fr Ihre Region zustndigen autorisiertenSystemtechnik-Kundendienst erfahren Sie ber die zentrale Ser-vicehotline der Glen Dimplex Deutschland GmbH.Glen Dimplex Deutschland GmbHGeschftsbereich DimplexKundendienst SystemtechnikAm Goldenen Feld 1895326 Kulmbach

    Fr die Auftragsbearbeitung werden die Erzeugnisnummer E-Nr.und das Fertigungsdatum FD des Gertes bentigt. Diese Anga-ben befinden sich auf dem Typschild in dem stark umrandetenFeld.

    Kundendienstadresse:

    Tel.-Nr.:Fax.-Nr.:E-Mail-Adresse:

    Internet:

    +49 (0) 9221 709 562+49 (0) 9221 709 [email protected]@dimplex.dewww.dimplex.de

  • www.dimplex.de E-1

    Engl

    ish

    Table of contents1 Please Read Immediately .............................................................................................................E-2

    1.1 Important Information..............................................................................................................................E-21.2 Legal Regulations and Directives ...........................................................................................................E-21.3 Energy-Efficient Use of the Heat Pump ..................................................................................................E-2

    2 Purpose of the Heat Pump ...........................................................................................................E-22.1 Application ..............................................................................................................................................E-22.2 Operating Principle .................................................................................................................................E-2

    3 Basic Device ..................................................................................................................................E-3

    4 Transport........................................................................................................................................E-3

    5 Set-up .............................................................................................................................................E-45.1 General Information ................................................................................................................................E-45.2 Sound Emissions ....................................................................................................................................E-4

    6 Installation .....................................................................................................................................E-46.1 General Information ................................................................................................................................E-46.2 Heating System Connection ...................................................................................................................E-46.3 Heat Source Connection.........................................................................................................................E-46.4 Electrical Connection ..............................................................................................................................E-5

    7 Commissioning .............................................................................................................................E-57.1 General Information ................................................................................................................................E-57.2 Preparation .............................................................................................................................................E-57.3 Start-up Procedure .................................................................................................................................E-5

    8 Maintenance and Cleaning ...........................................................................................................E-68.1 Maintenance ...........................................................................................................................................E-68.2 Cleaning the Heating System .................................................................................................................E-68.3 Cleaning the Heat Source System..........................................................................................................E-68.4 Water Quality Requirements...................................................................................................................E-6

    9 Faults / Trouble-Shooting.............................................................................................................E-6

    10 Decommissioning / Disposal .......................................................................................................E-6

    11 Device Information ........................................................................................................................E-7

    Anhang / Appendix / Annexes ............................................................................................................ A-I

  • English

    11 Please Read Immediately

    1.1 Important Information

    ATTENTION!The well water must comply with the required water quality standards.

    ATTENTION!The heat pump is not secured to the wooden pallet.

    ATTENTION!The heat pump must not be tilted more than 45 (in any direction).

    ATTENTION!Do not use the holes in the panel assemblies for lifting the device!

    ATTENTION!Flush the heating system prior to connecting the heat pump.

    ATTENTION!The heat pump must be started up in accordance with the installation andoperating instructions of the heat pump controller.

    ATTENTION!We recommend the installation of a suitable corrosion protection systemto prevent the formation of deposits (e.g. rust) in the condenser of theheat pump.

    ATTENTION!Any work on the heat pump may only be performed by authorised andqualified after-sales service technicians.

    ATTENTION!Disconnect all electrical circuits from the power source prior to openingthe device.

    1.2 Legal Regulations and Directives

    This heat pump conforms to all relevant DIN/VDE regulationsand EU directives. Refer to the EC Declaration of Conformity inthe appendix for details.The heat pump must be connected to the power supply in com-pliance with all relevant VDE, EN and IEC standards. Any furtherconnection requirements stipulated by local utility companiesmust also be observed.The heat pump is to be connected to the heat source system andthe heating system in accordance with all applicable regulations.Persons, especially children, who are not capable of operatingthe device safely due to their physical, sensory or mental abilitiesor their inexperience or lack of knowledge, must not operate thisdevice without supervision or instruction by the person in charge. Children must be supervised to ensure that they do not play withthe device.

    1.3 Energy-Efficient Use of the Heat Pump

    By operating this heat pump you are helping to protect our envi-ronment. Both the heating system and the heat source must beproperly designed and dimensioned to ensure efficient operation.It is particularly important to keep water flow temperatures as lowas possible. All connected energy consumers should thereforebe suitable for low flow temperatures. Raising the heating watertemperature by 1 K corresponds to an increase in energy con-sumption of approx. 2.5 %. Low-temperature heating systems with flow temperaturesbetween 30 C and 50 C are particularly well-suited for energy-efficient operation.

    2 Purpose of the Heat Pump

    2.1 ApplicationThe water-to-water heat pump is designed for use in existing ornewly built heating systems. Water is used as the heat transfermedium. It can be supplied by wells or other water systems.In order to eliminate the risk of corrosion at the evaporator, thewell water must be evaluated regarding the corrosion behaviourof metallic materials according to DIN 50930.Details can be found in the project planning and installation man-ual for heat pumps for heating purposes.

    ATTENTION!The well water must comply with the required water quality standards.

    2.2 Operating PrincipleA well pump conveys the water to the evaporator of the heatpump. There the heat is transferred to the refrigerant in the refrig-erating circuit.The refrigerant is drawn in by the electrically driven compressor,compressed and pumped to a higher temperature level. Theelectrical power needed to run the compressor is not lost in thisprocess. Most of it is absorbed by the refrigerant as well.Subsequently, the refrigerant is passed through the condenserwhere it transfers its heat energy to the heating water.Depending on the set operating point (thermostat setting), theheating water is thus heated up to a max. of 60 C.E-2

  • Engl

    ish

    43 Basic DeviceThe basic device consists of a ready-to-use heat pump for indoorinstallation, complete with casing, switch box and integrated con-troller. The refrigerating cycle contains the refrigerant R407C.The refrigerant is CFC-free, non-ozone depleting and non-com-bustible. All components required for the operation of the heat pump arelocated in the switch box. An external wall temperature sensor in-cluding fixing accessories and a dirt trap are supplied with theheat pump. The power feed for the load current and the controlcurrent must be installed by the customer.The supply lead of the well pump (to be provided by the cus-tomer) must be connected to the switch box. It is important to en-sure that the integrated motor protection is sufficient for the pumpprovided by the customer.

    1) Evaporator2) Switch box3) Liquifier4) Compressor

    4 TransportA lift truck is suited for transporting the unit on a level surface.Carrying straps may be used if the heat pump needs to be trans-ported on an uneven surface or carried up or down stairs. Thesestraps can be passed directly underneath the wooden pallet.

    ATTENTION!The heat pump is not secured to the wooden pallet.

    ATTENTION!The heat pump must not be tilted more than 45 (in any direction).

    Use the holes provided in the sides of the frame to lift the unitwithout the pallet. The side panel assemblies must be removedfor this purpose. Any commercially available length of pipe canbe used as a carrying aid.

    ATTENTION!Do not use the holes in the panel assemblies for lifting the device!

    www.dimplex.de E-3

  • English

    55 Set-up

    5.1 General InformationThe unit may only be installed indoors in rooms with low humidityon a level, smooth and horizontal surface. The entire base of theframe should lie directly on the floor to ensure a good soundproofseal. If this is not the case, additional sound insulation measuresmay be necessary.The heat pump must be installed so that maintenance work canbe carried out without being hindered. This can be ensured bymaintaining a clearance of approx. 1 m in front of and on eachside of the heat pump.

    5.2 Sound EmissionsThe heat pump operates silently due to efficient sound insulation.To prevent noise transmission to the foundation, a suitable,sound dampening rubber mat should be placed underneath thebase frame of the heat pump.To prevent any sound from being transmitted to the heating sys-tem, we recommend connecting the heat pump to the heatingsystem by means of hose sections.

    6 Installation

    6.1 General InformationThe following connections need to be established on the heatpump: Flow and return flow of the well system Flow and return flow of the heating system Power supply

    6.2 Heating System Connection

    ATTENTION!Flush the heating system prior to connecting the heat pump.

    Before connecting the heating water system to the heat pump,the heating system must be flushed to remove any impurities,residue from sealants, etc. Any accumulation of deposits in theliquifier could cause the heat pump to completely break down.Once the heating system has been installed, it must be filled, de-aerated and pressure-tested.

    Minimum heating water flow rateThe minimum heating water flow rate through the heat pumpmust be assured in all operating states of the heating system.This can be accomplished, for example, by installing either amanifold without differential pressure or an overflow valve. Theprocedure for adjusting an overflow valve is described in theChapter Start-up.

    Antifreeze protection for installation locations prone to frostThe antifreeze function of the heat pump controller is activewhenever the controller and the heat circulating pumps are readyfor operation. If the heat pump is taken out of service or in theevent of a power failure, the system has to be drained. The heat-ing circuit should be operated with a suitable antifreeze if heatpump systems are implemented in buildings where a power fail-ure can not be detected (holiday home).

    6.3 Heat Source ConnectionThe following procedure must be observed when connecting theheat source:Connect the well pipes to the heat pump flow and return flow.

    ATTENTION!The well water must comply with the required water quality standards.

    The hydraulic plumbing diagram must be adhered to.E-4

  • Engl

    ish

    7.36.4 Electrical ConnectionThe following electrical connections need to be established onthe heat pump. Connection of the control line to the control panel of the heat

    pump via terminal X1: L/N/PE. Connection of the mains cable to the control panel of the

    heat pump via terminal X5: L/N/PE. Connection of the mains cable of the well pump to the con-

    trol panel of the heat pump via terminal X5: L1/N1/PE. Connection of the well pump (to be provided by the cus-

    tomer) to the control panel of the heat pump via terminal X1:PE and pump contactor K5: 14/24.

    Ensure that the supply voltage for these terminals cannot beswitched off by the tariff contactor when connecting the mainscable of the well pump, in order to enable the turn-off delay of thewell pump.All electrical components required for the operation of the heatpump are located on the control panel.For detailed instructions concerning the connection and function-ing of the heat pump controller (e.g. external wall sensor includedin the scope of supply), refer to the operating manual suppliedwith the controller.An disconnecting device with a contact gap of at least 3 mm (e.g.utility blocking contactor or power contactor) as well as a 1-polecircuit breaker have to be provided by the customer. The re-quired conductor cross-section is to be selected according to thepower consumption of the heat pump, the technical connectionrequirements of the respective utility company as well as all ap-plicable regulations. Details on the power consumption of theheat pump are listed on both the product information sheet andthe type plate. The connection terminals are designed for a max.conductor cross section of 10 mm2.

    7 Commissioning

    7.1 General InformationTo ensure that start-up is performed correctly, it should only becarried out by an after-sales service technician authorised by themanufacturer. This may be a condition for extending the guaran-tee (see Warranty Service).

    7.2 PreparationThe following items need to be checked prior to start-up: The heat pump must be fully connected, as described in

    Chapter 6. The heat source system and the heating circuit must have

    been filled and checked. All valves that could impair proper flow in the well and heat-

    ing circuits must be open. The heat pump controller must be adapted to the heating

    system in accordance with the controllers operating instruc-tions.

    7.3 Start-up ProcedureThe heat pump is started up via the heat pump controller.

    ATTENTION!The heat pump must be started up in accordance with the installation andoperating instructions of the heat pump controller.

    If an overflow valve is fitted to assure the minimum heating waterflow rate, the valve must be set in accordance with the require-ments of the respective heating system. Incorrect adjustmentcan lead to faulty operation and increased energy consumption.We recommend carrying out the following procedure to correctlyadjust the overflow valve:Close all of the heating circuits that may also be closed duringoperation (depending on the type of heat pump usage) so thatthe most unfavourable operating state - with respect to the waterflow rate - is achieved. This normally means the heating circuitsof the rooms on the south and west sides of the building. At leastone heating circuit must remain open (e.g. bathroom).The overflow valve should be opened far enough to produce themaximum temperature spread between the heating flow and re-turn flow listed in the table below for the current heat source tem-perature. The temperature spread should be measured as closeas possible to the heat pump. The heating element of mono en-ergy systems should be disconnected.

    Any faults occurring during operation are displayed on the heatpump controller and can be corrected as described in the operat-ing manual of the heat pump controller.

    Heat sourcetemperature

    Max. temperature spreadbetween heating flow and return

    flowFrom To7 C 12 C 10 K

    13 C 18 C 11 K

    19 C 25 C 12 Kwww.dimplex.de E-5

  • English

    88 Maintenance and Cleaning

    8.1 MaintenanceThe heat pump is maintenance-free. To prevent faults due tosediment in the heat exchangers, care must be taken to ensurethat no impurities can enter either the heat source system or theheating system. In the event that operating malfunctions due tocontamination occur nevertheless, the system should be cleanedas described below.

    8.2 Cleaning the Heating SystemThe ingress of oxygen into the heating water circuit may result inthe formation of oxidation products (rust), particularly if steelcomponents are used. This oxygen enters the heating system viathe valves, the circulating pumps and/or plastic pipes. It is there-fore essential - in particular with respect to the piping of under-floor heating systems - that only diffusion-proof materials areused.

    ATTENTION!We recommend the installation of a suitable corrosion protection systemto prevent the formation of deposits (e.g. rust) in the condenser of theheat pump.

    Residue from lubricants and sealants may also contaminate theheating water.In the case of severe contamination leading to a reduction in theperformance of the liquifier in the heat pump, the system must becleaned by a heating technician.According to todays state of knowledge, we recommend using a5 % phosphoric acid solution for cleaning purposes. However, ifcleaning needs to be performed more frequently, a 5 % formicacid solution should be used. In either case, the cleaning fluid should be at room temperature.We recommend flushing the heat exchanger in the direction op-posite to the normal flow direction.To prevent acidic cleaning agents from entering the heating sys-tem circuit, we recommend connecting the flushing device di-rectly to the flow and return flow of the liquifier. It is important thatthe system be thoroughly flushed using appropriate neutralisingagents to prevent any damage from being caused by cleaningagent residue remaining in the system.Acids must be used with great care and all relevant regulations ofthe employers liability insurance associations must be adheredto.If in doubt, contact the manufacturer of the chemicals!

    8.3 Cleaning the Heat Source System

    A dirt trap is inserted in the heat source inlet of the heat pump toprotect the evaporator against the ingress of impurities. Whenthe system is first put into operation, the filter screen of the dirttrap should be cleaned in relatively short intervals. These inter-vals can be prolonged once the amount of impurities decreases.

    8.4 Water Quality Requirements The ground water should not contain any substances that couldform deposits. The limit values for iron (< 0.2 mg/l) and manga-nese (< 0.1 mg/l) must be adhered to prevent iron ochre sedi-mentation in the heat pump system.The use of surface water or water containing salt is not permissi-ble. Your local water utility can provide you with general informa-tion regarding the possible use of ground water. Water analysesare carried out by specially-equipped laboratories. It is not necessary to carry out a water analysis with regard toevaporator corrosion if the annual mean temperature of theground water does not exceed 13 C). In this case, the limit values for iron and manganese mustbe adhered to (iron ochre sedimentation).

    9 Faults / Trouble-Shooting

    This heat pump is a quality product and is designed for trouble-free operation. In the event that a fault should occur, it will beshown on the heat pump manager display. Simply consult theFaults and Trouble-Shooting page in the operating instructions ofthe heat pump controller.If you cannot correct the fault yourself, please contact your after-sales service technician.

    ATTENTION!Any work on the heat pump may only be performed by authorised andqualified after-sales service technicians.

    ATTENTION!Disconnect all electrical circuits from the power source prior to openingthe device.

    10 Decommissioning / Disposal

    Before removing the heat pump, disconnect it from the powersource and close all valves. Observe all environmentally-relevantrequirements regarding the recovery, recycling and disposal ofmaterials and components in accordance with all applicablestandards. Particular attention should be paid to the proper dis-posal of refrigerants and refrigeration oils.E-6

  • Engl

    ish

    1111 Device Information1 Type and order code WI 9ME WI 14ME2 Design2.1 Degree of protection according to EN 60 529 IP 20 IP 20

    2.2 Installation Location Indoors Indoors

    3 Performance data EN 255 EN 14511 EN 255 EN 145113.1 Operating temperature limits:

    Heating water flow C Up to 55 Up to 55

    Cold water (heat source) C +7 to +25 +7 to +25

    3.2 Temperature spread of heating waterat W10 / W35 K 9.5 5.0 8.8 5.0

    3.3 Heat output / COP at W7 / W55 1 kW / ---

    1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation shouldalso be taken into consideration. The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 C and heating water flow temperature 55 C.

    6.9 / 2.5 12.2 / 2.3

    at W10 / W50 1 kW / --- 7.7 / 3.2 13.4 / 3.4

    at W10 / W45 1 kW / --- 7.7/ 3.7 13.4 / 3.8

    at W10 / W35 1 kW / --- 8.3 / 5.1 8.2 / 4.8 13.6 / 5.0 13.5 / 4.7

    3.4 Heating water flow with an internal pressure differential of m/h / Pa 0.75 / 7000 1.4 / 24000 1.3 / 7000 2.3 / 22000

    3.5 Cold water flow rate at an internal pressure differential of(heat source) m/h / Pa 2.0 / 6200 3.3 / 19000

    3.6 Refrigerant; total filling weight type / kg R407C / 1.7 R407C / 1.9

    4 Dimensions, connections and weight4.1 Device dimensions without connections 2 H x W x L mm

    2. Note that additional space is required for pipe connections, operation and maintenance.

    1445 x 650 x 575 1445 x 650 x 575

    4.2 Device connections to heating system Inch G 1" external G 1" external

    4.3 Device connections to heat source Inch G 1" external G 1" external

    4.4 Weight of the transportable unit(s) incl. packing kg 156 165

    5 Electrical Connection5.1 Nominal voltage; fuse protection V / A 230 / 16 230 / 25

    5.2 Nominal power consumption 1 W10 W35 kW 1.62 1.69 2.72 2.87

    5.3 Starting current with soft starter A 26 45

    5.4 Nominal current W10 W35 / cos A / --- 0.8 9.18 14.8 16.66 Complies with the European safety regulations 3

    3. See CE declaration of conformity

    3

    7 Additional model features7.1 Water in device protected against freezing 4

    4. The heat circulating pump and the heat pump controller must always be ready for operation.

    Yes Yes

    7.2 Performance levels 1 1

    7.3 Controller internal/external Internal Internalwww.dimplex.de E-7

  • F-1

    Franais

    Table des matires1 A lire immdiatement ! ................................................................................................................. F-2

    1.1 Remarques importantes..........................................................................................................................F-21.2 Dispositions lgales et directives ............................................................................................................F-21.3 Utilisation de la pompe chaleur pour conomiser de l'nergie.............................................................F-2

    2 Utilisation de la pompe chaleur................................................................................................ F-22.1 Domaine dutilisation...............................................................................................................................F-22.2 Fonctionnement ......................................................................................................................................F-2

    3 Appareil de base ........................................................................................................................... F-3

    4 Transport ....................................................................................................................................... F-3

    5 Installation..................................................................................................................................... F-45.1 Gnralits..............................................................................................................................................F-45.2 Emissions sonores..................................................................................................................................F-4

    6 Montage ......................................................................................................................................... F-46.1 Remarques dordre gnral ....................................................................................................................F-46.2 Branchement ct installation de chauffage ...........................................................................................F-46.3 Raccordement ct source de chaleur ...................................................................................................F-46.4 Branchements lectriques ......................................................................................................................F-5

    7 Mise en service ............................................................................................................................. F-57.1 Remarques dordre gnral ....................................................................................................................F-57.2 Prparation .............................................................................................................................................F-57.3 Procdures suivre lors de la mise en service ......................................................................................F-5

    8 Entretien / nettoyage .................................................................................................................... F-68.1 Entretien..................................................................................................................................................F-68.2 Nettoyage ct chauffage .......................................................................................................................F-68.3 Nettoyage ct source de chaleur ..........................................................................................................F-68.4 Qualit de leau .......................................................................................................................................F-6

    9 Dfaillances / recherche de pannes............................................................................................ F-6

    10 Mise hors service / mise au rebut ............................................................................................... F-6

    11 Informations sur les appareils..................................................................................................... F-7

    Anhang / Appendix / Annexes............................................................................................................. A-I

  • Fran

    ais

    2.21 A lire immdiatement !

    1.1 Remarques importantes

    ATTENTION !Leau du puits doit tre conforme la qualit de leau exige.

    ATTENTION !La pompe chaleur nest pas fixe la palette en bois.

    ATTENTION !Lors du transport, langle dinclinaison de la pompe chaleur ne doit pasdpasser 45 (dans tous les sens).

    ATTENTION !Ne pas soulever lappareil en utilisant les orifices de lhabillage !

    ATTENTION !Rincer l'installation de chauffage avant de brancher la pompe chaleur.

    ATTENTION !La mise en service de la pompe chaleur doit seffectuer conformmentaux instructions de montage et dutilisation du rgulateur de pompe chaleur.

    ATTENTION !Il est recommand de faire appel un systme appropri de protectioncontre la corrosion pour viter les dpts (rouille par ex.) dans lecondensateur de la pompe chaleur.

    ATTENTION !Les travaux sur la pompe chaleur doivent tre effectus uniquement pardes techniciens qualifis et agrs.

    ATTENTION !Avant douvrir lappareil, assurez-vous que tous les circuits lectriquessont bien hors tension.

    1.2 Dispositions lgales et directives

    La pompe chaleur est conforme toutes les prescriptions DIN/VDE et toutes les directives CE affrentes. Celles-ci sont non-ces dans la dclaration de conformit CE en annexe.Le branchement lectrique de la pompe chaleur doit tre ra-lis selon les normes VDE, EN et CEI en vigueur. En outre, ilconvient de respecter les conditions techniques de branchementdes fournisseurs dnergie. La pompe chaleur doit tre intgre l'installation de chauf-fage et de source de chaleur, en conformit avec les prescrip-tions affrentes.Les personnes, en particulier les enfants, qui, compte tenu deleurs capacits physiques, sensorielles ou intellectuelles, ou deleur manque d'exprience ou de connaissances, ne sont pas enmesure d'utiliser l'appareil en toute sret, ne devraient pas lefaire en l'absence ou sans instructions d'une personne responsa-ble.Les enfants doivent tre surveills pour viter qu'ils ne jouentavec l'appareil.

    1.3 Utilisation de la pompe chaleur pour conomiser de l'nergie

    En utilisant cette pompe chaleur, vous contribuez prserverlenvironnement. Pour obtenir un fonctionnement efficace, il esttrs important de dimensionner prcisment linstallation dechauffage et la source de chaleur. Dans cette optique, une atten-tion toute particulire doit tre prte aux tempratures de dpartde leau, qui doivent tre les plus basses possible. Cest pour-quoi tous les consommateurs dnergie relis linstallation doi-vent tre dimensionns pour des tempratures de dpart bas-ses. Une temprature deau de chauffage qui augmente de 1 Ksignifie une augmentation de la consommation dnergie de2,5% environ. Un chauffage basse temprature avec des temp-ratures dpart entre 30 et 50 C saccorde bien avec un fonction-nement conomique en nergie.

    2 Utilisation de la pompe chaleur

    2.1 Domaine dutilisationLa pompe chaleur eau-eau peut tre utilise dans les installa-tions de chauffage dj en place ou nouvelles. Leau sert defluide caloporteur. Celle-ci peut tre alimente partir de puitsou dinstallations quivalentes.Pour exclure tout risque de corrosion au niveau du compresseur,le risque de corrosion des matriaux mtalliques doit tre valupour leau du puits selon la norme DIN 50930.Des informations plus dtailles se trouvent dans le manuel deconduite de projet et dinstallation de pompes chaleur pourchauffage

    ATTENTION !Leau du puits doit tre conforme la qualit de leau exige.

    2.2 FonctionnementUne pompe de puits amne leau vers lvaporateur de la pompe chaleur, dans lequel la chaleur est dlivre au fluide frigorignedu circuit frigorifique.Le fluide frigorigne est aspir par le compresseur commandelectrique, compress et pomp un niveau de tempratureplus lev. Lnergie lectrique mise disposition tout au long dece procd nest pas perdue, elle est transfre au contrairegalement en grande partie au fluide frigorigne.Le fluide frigorigne arrive alors dans le condenseur o sontour, il transmet lnergie thermique leau de chauffage.Ainsi, leau de chauffage chauffe et atteint des tempraturespouvant aller, en fonction du point de fonctionnement, jusqu60 C.www.dimplex.de F-2

  • Franais

    33 Appareil de baseIl s'agit d'une pompe chaleur pour installation intrieure, prte brancher, avec jaquette, salle de distribution et rgulateur int-gr. Le fluide frigorigne R407C est utilis dans le circuit rfrig-rant, il est sans HCFC, non combustible et ne dtruit pas la cou-che d'ozone.Dans le local de pilotage se trouvent toutes les pices ncessai-res lutilisation de la pompe chaleur. Une sonde pour mesurerla temprature du mur extrieur et son petit matriel de fixationainsi qu'un collecteur d'impurets sont livrs avec l'appareil. Lesraccordements pour la tension destine au courant de charge etde commande doivent tre effectus par le client.La ligne d'alimentation de la pompe de puits, installe par leclient, doit tre raccorde la salle de distribution. Il faut demme contrler si la protection moteur installe en usine est suf-fisante pour la pompe monte sur site.

    1) Evaporateur2) Salle de distribution3) Condenseur4) Compresseur

    4 TransportLe transport par chariot lvateur convient bien un dplace-ment sur surface plane. Si la pompe chaleur doit tre convoyesur une surface non plane ou dans des escaliers, il est possiblede le faire l'aide de sangles, que l'on peut glisser directementsous la palette en bois.

    ATTENTION !La pompe chaleur nest pas fixe la palette en bois.

    ATTENTION !Lors du transport, langle dinclinaison de la pompe chaleur ne doit pasdpasser 45 (dans tous les sens).

    Pour soulever lappareil sans palette, veuillez utiliser les orificesprvus dans le chssis, sur les cts. Retirer cet effet les pan-neaux latraux de lhabillage. Pour vous aider porter lappareil,un tube quelconque fera laffaire.

    ATTENTION !Ne pas soulever lappareil en utilisant les orifices de lhabillage !

    F-3

  • Fran

    ais

    6.35 Installation

    5.1 GnralitsN'installer l'appareil qu' l'intrieur, dans des pices non humi-des sur une surface plane, lisse et horizontale. Ici, le chssis dela pompe chaleur doit adhrer au sol sur toute sa circonfrenceafin de garantir une isolation acoustique approprie. Si tel n'estpas le cas, des mesures d'absorption acoustique complmentai-res seront ventuellement ncessaires.La pompe chaleur doit tre mise en place de telle manire quele service aprs-vente puisse y accder sans problmes, ce quine fait aucun doute, si on laisse un espace denv. 1 m devant etsur les cts de la pompe chaleur.

    5.2 Emissions sonoresEn raison de lefficacit de son isolation phonique, la pompe chaleur est trs silencieuse. Pour viter la transmission de vibra-tions sur les fondations, un tapis amortissant caoutchout appro-pri devrait tre pos sous le chssis de base de la pompe chaleur.Pour viter la transmission de bruits au systme de chauffage, ilest recommand de raccorder la pompe chaleur au systme dechauffage l'aide de tuyaux souples.

    6 Montage

    6.1 Remarques dordre gnralLes raccordements suivants doivent tre raliss sur la pompe chaleur : Circuits dpart et retour installation de puits Circuits dpart et retour du chauffage Alimentation lectrique

    6.2 Branchement ct installation de chauffage

    ATTENTION !Rincer l'installation de chauffage avant de brancher la pompe chaleur.

    Avant de procder au raccordement de la pompe chaleur cteau de chauffage, linstallation de chauffage doit tre rince pourliminer dventuelles impurets et les restes ventuels des ma-triaux dtanchit ou autres. Une accumulation de dpts di-vers dans le condenseur est susceptible d'entraner une d-faillance totale de la pompe chaleur.Une fois le montage ct chauffage termin, linstallation dechauffage devra tre remplie, purge et prouve la pression.

    Dbit d'eau de chauffage minimumQuel que soit l'tat de fonctionnement de l'installation de chauf-fage, un dbit d'eau de chauffage minimum doit tre garanti dansla pompe chaleur. C'est tout fait ralisable en montant un dis-tributeur exempt de pression diffrentielle ou une vanne de trop-plein. Vous trouverez des explications quant au rglage d'unevanne de trop-plein dans le chapitre Mise en service .

    Protection antigel dans le cas dune installation expose au gelLa fonction de protection antigel du rgulateur est active dsque le rgulateur et les circulateurs de chauffage sont prts fonctionner. Linstallation doit tre vidange dans le cas dunemise hors service de la pompe chaleur ou en cas de panne decourant. Pour les installations de pompe chaleur qui pourraienttre victimes de pannes de courant non dcelables (maison devacances), le circuit de chauffage doit fonctionner avec une pro-tection anti-gel approprie.

    6.3 Raccordement ct source de chaleur

    Pour le raccordement, il faut procder exactement comme indi-qu ci-aprs :raccorder les conduites de puits aux circuits dpart et retour dela pompe chaleur.

    ATTENTION !Leau du puits doit tre conforme la qualit de leau exige.

    Suivre pour cela les indications du schma hydraulique.www.dimplex.de F-4

  • Franais

    6.46.4 Branchements lectriquesLes raccordements lectriques suivants doivent tre raliss surla pompe chaleur : Branchement de la ligne de commande sur le panneau de

    commande de la pompe chaleur par la borne X1 : L/N/PE. Branchement de la ligne de charge sur le panneau de com-

    mande de la pompe chaleur par la borne X5 : L/N/PE. Branchement de la ligne de charge pompe de puits sur le

    panneau de commande de la pompe chaleur par la borneX5 : L1N1/PE.

    Branchement de la pompe de puits (par le client) sur le pan-neau de commande de la pompe chaleur par la borne X1 :PE et contacteur de pompe K5 : 14/24

    Lors du branchement de la ligne de charge de la pompe de puits,il faut sassurer que lalimentation en tension de ces bornes nepuissent pas tre interrompue par le contacteur tarif, afin de pou-voir garantir le retard de dsenclenchement de la pompe depuits.Tous les composants lectriques ncessaires lutilisation de lapompe chaleur se trouvent sur le panneau de commande.Des instructions prcises sur le raccordement et la fonction durgulateur de pompe chaleur (par exemple sonde mur ext-rieur) vous sont fournies dans les instructions d'utilisation du r-gulateur jointes la machine.Il faut prvoir une dconnexion avec au moins 3 mm dcarte-ment douverture de contact (p. ex. disjoncteur ou contacteur depuissance du fournisseur dnergie) ainsi quun coupe-circuitautomatique 1 ple. La section du conducteur ncessaire doittre dtermine en fonction de la puissance absorbe de lapompe chaleur, des conditions techniques de branchement dechaque fournisseur dnergie et selon les prescriptions affren-tes. Vous trouverez les donnes sur la puissance absorbe parla pompe chaleur dans les informations produits ou sur la pla-que signaltique. Les bornes de connexion sont dimensionnespour une section du conducteur de 10 mm maximum.

    7 Mise en service

    7.1 Remarques dordre gnralPour garantir une mise en service en rgle, cette dernire doittre effectue par un service aprs-vente agr par le construc-teur. Ceci permet de prolonger la garantie sous certaines condi-tions.

    7.2 PrparationAvant la mise en service, il est impratif de procder aux vrifica-tions suivantes : tous les raccordements de la pompe chaleur doivent tre

    raliss comme dcrit au chapitre 6. l'installation de source de chaleur et le circuit de chauffage

    doivent tre remplis et tests. dans les circuits de chauffage et de puits, toutes les vannes

    susceptibles de perturber l'coulement doivent tre ouver-tes.

    le rgulateur de la pompe chaleur doit tre accord l'ins-tallation de chauffage conformment ses instructions deservice.

    7.3 Procdures suivre lors de la mise en service

    La mise en service de la pompe chaleur seffectue via le rgu-lateur de pompe chaleur.

    ATTENTION !La mise en service de la pompe chaleur doit seffectuer conformmentaux instructions de montage et dutilisation du rgulateur de pompe chaleur.

    Si le dbit minimal en eau de chauffage est assur par unevanne de trop-plein, il faut l'adapter l'installation de chauffage.Un mauvais rglage pourrait conduire divers messages der-reur et une augmentation du besoin en nergie lectrique. Pourrgler la soupape de trop-plein correctement, nous vous con-seillons de procder de la manire suivante.Fermez tous les circuits de chauffage pouvant l'tre en phase defonctionnement, selon l'utilisation qu'il en est faite ; ceci ayantpour but d'obtenir le dbit d'eau le plus dfavorable. En rgle g-nrale, ce sont les circuits de chauffage des locaux donnant surle ct sud et ouest. Au moins un des circuits de chauffage doitrester ouvert (par ex. salle de bains).La vanne de trop-plein est ouvrir au maximum pour obtenirl'talement maximal de temprature, indiqu dans le tableau sui-vant, entre circuit dpart et retour du chauffage pour la tempra-ture actuelle des sources dnergie. Il faut mesurer l'talementde temprature le plus proche possible de la pompe chaleur.La cartouche chauffante doit tre dsactive pour des installa-tions mono-nergtiques.

    Les anomalies qui se produisent lors du fonctionnement sontgalement affiches au rgulateur PAC et peuvent tre limi-nes suivant les indications du manuel de service du rgulateur.

    Tempraturesource de chaleur

    Diffrence de temprature max.entre circuits dpart et retour du

    chauffagede 7 C 12 C 10 K

    13 C 18 C 11 K

    19 C 25 C 12 KF-5

  • Fran

    ais

    108 Entretien / nettoyage

    8.1 EntretienLa pompe chaleur travaille sans interventions en maintenance.Pour viter des dysfonctionnements dus des dpts dans leschangeurs thermiques de la pompe chaleur, il faut veiller cequ'aucune sorte de dpt ne puisse s'introduire dans les installa-tions de chauffage et de source de chaleur. Si des dysfonction-nements dus des impurets devaient quand mme se produire,linstallation devra tre nettoye comme indiqu ci-aprs.

    8.2 Nettoyage ct chauffageLoxygne est susceptible dentraner la formation de produitsdoxydation (rouille) dans leau de chauffage, notamment lorsquedes composants en acier sont utiliss. Celui-ci gagne le systmede chauffage par les vannes, les circulateurs ou les tuyaux enmatire plastique. Cest pourquoi il faut veiller ce que linstalla-tion reste tanche la diffusion, notamment en ce qui concerneles tuyaux du chauffage au sol.

    ATTENTION !Il est recommand de faire appel un systme appropri de protectioncontre la corrosion pour viter les dpts (rouille par ex.) dans lecondensateur de la pompe chaleur.

    Il est galement possible que leau de chauffage soit souille pardes restes de graisse et dagents dtanchification.Si en raison dimpurets la puissance du condenseur de lapompe chaleur se trouve rduite, linstallation devra tre net-toye par linstallateur.Dans l'tat actuel des connaissances, nous conseillons de pro-cder au nettoyage avec de lacide phosphorique 5 % ou, si lenettoyage est plus frquent, avec de lacide formique 5 %.Dans les deux cas, le liquide de nettoyage doit tre la tempra-ture ambiante. Il est recommand de nettoyer l'changeur dechaleur dans le sens contraire au sens normal du dbit.Pour viter linfiltration de nettoyant contenant de lacide dans lecircuit de linstallation de chauffage, nous vous recommandonsde raccorder lappareil de nettoyage directement sur le dpart etle retour du condenseur. Il faut ensuite soigneusement rincer laide de produits neutralisants adquats, afin dviter tous dom-mages provoqus par dventuels restes de produits de net-toyage dans le systme.Les acides doivent tre utiliss avec prcaution et les prescrip-tions des caisses de prvoyance des accidents doivent tre res-pectes.En cas de doute, prendre contact avec les fabricants des pro-duits chimiques !

    8.3 Nettoyage ct source de chaleur

    Sur la pompe chaleur, un collecteur dimpurets est montdans louverture dadmission de la source de chaleur, afin deprotger lvaporateur des salissures. il est recommand audbut de nettoyer le tamis du filtre du collecteur dimpurets des intervalles relativement courts. Si moins de souillures sont signaler, augmenter lintervalle de temps entre deux nettoyagesen consquence.

    8.4 Qualit de leauLeau de la nappe phratique ne doit contenir aucune substancesusceptible de se dposer et les valeurs limites de FER-(< 0,2 mg/l) et MANGANESE (< 0,1 mg/l) doivent tre respec-tes pour viter un dpt docre dans linstallation.Lutilisation deau de surface ou deau charge de sel nest pasautorise. Vous pouvez vous adresser aux entreprises localesdapprovisionnement en eau pour obtenir des premiers rensei-gnements sur une exploitation ventuelle de leau de la nappephratique. Les analyses deau sont effectues par des labora-toires spcialiss dans les techniques de leau.Il nest pas ncessaire de procder une analyse de leau envue de la corrosion de lvaporateur, si la temprature de leausouterraine ne dpasse pas une temprature moyenne annuellede 13 C. Dans ce cas, il suffit de respecter les valeurs limites defer et de manganse (dpt docre).

    9 Dfaillances / recherche de pannes

    Cette pompe chaleur est un produit de qualit et elle devraitfonctionner sans dysfonctionnements. Si un dysfonctionnementdevait quand mme survenir, celui-ci sera affich sur lcran durgulateur de pompe chaleur. Rfrez-vous pour cela la pagedes dysfonctionnements et de recherche de panne dans les ins-tructions du rgulateur de pompe chaleur.Si vous n'tes pas en mesure de remdier vous-mme au dys-fonctionnement, veuillez vous adresser au service aprs-ventecomptent.

    ATTENTION !Les travaux sur la pompe chaleur doivent tre effectus uniquement pardes techniciens qualifis et agrs.

    ATTENTION !Avant douvrir lappareil, assurez-vous que tous les circuits lectriquessont bien hors tension.

    10 Mise hors service / mise au rebut

    Avant de dmonter la pompe chaleur, il faut mettre la machinehors tension et fermer toutes les vannes. Il faut se conformer auxexigences relatives l'environnement quant la rcupration, larutilisation et llimination de consommables et de composantsen accord avec les normes en vigueur. Une attention toute parti-culire doit tre prte lvacuation du rfrigrant et de lhuilede la machine frigorifique, qui doit seffectuer selon les rgles delart.www.dimplex.de F-6

  • Franais

    1111 Informations sur les appareils

    1 Dsignation technique et commerciale WI 9ME WI 14ME2 Forme2.1 Degr de protection selon EN 60 529 IP 20 IP 20

    2.2 Emplacement intrieur intrieur

    3 Indications de puissance EN 255 EN14511 EN 255 EN145113.1 Temprature - limites dexploitation :

    Dpart eau de chauffage C moins de 55 moins de 55

    Eau froide (source de chaleur) C entre +7 et +25 entre +7 et +25

    3.2 Etalement de tempratures eau de chauffagepour W10 / W35 K 9,5 5,0 8,8 5,0

    3.3 Capacit thermique / coef. de puissancepour W7 / W55 1 kW / ---

    1. Ces indications caractrisent la taille et le rendement de linstallation. Le point de bivalence et la rgulation sont prendre en compte pour des considrations conomiques etnergtiques. Ici, B10 / W55 signifie par ex. : temprature extrieure 10 C et temprature dpart eau de chauffage 55 C.

    6,9 / 2,5 12,2 / 2,3

    pour W10 / W50 1 kW / --- 7,7 / 3,2 13,4 / 3,4

    pour W10 / W45 1 kW / --- 7,7 / 3,7 13,4 / 3,8

    pour W10 / W35 1 kW / --- 8,3 / 5,1 8,2 / 4,8 13,6 / 5,0 13,5 / 4,7

    3.4 Dbit deau de chauffage avec pression diff. int. m/h / Pa 0,75 / 7000 1,4 / 24000 1,3 / 7000 2,3 / 22000

    3.5 Dbit deau froide en cas de diff. de pression interne(source de chaleur) m/h / Pa 2,0 / 6200 3,3 / 19000

    3.6 Fluide frigorigne ; poids au remplissage total type / kg R407C / 1,7 R407C / 1,9

    4 Dimensions, raccordements et poids4.1 Dimensions de lappareil sans raccordements 2 H x l x L mm

    2. Tenir compte de la place ncessaire plus importante pour le raccordement des tuyaux, la commande et lentretien.

    1445 x 650 x 575 1445 x 650 x 575

    4.2 Raccordements de lappareil pour le chauffage pouce G 1" a G 1" a

    4.3 Raccordements de lappareil pour la source de chaleur pouce G 1" a G 1" a

    4.4 Poids de/des units de transport, emballage compris kg 156 165

    5 Branchements lectriques5.1 Tension nominale ; protection par fusibles V / A 230 / 16 230 / 25

    5.2 Consommation nominale 1 W10 W35 kW 1,62 1,69 2,72 2,87

    5.3 Courant de dmarrage avec dmarreur progressif A 26 45

    5.4 Courant nominal W10 W35 / cos A / --- 8,0 9,18 14,8 16,66 Conforme aux dispositions de scurit europennes 3

    3. Voir dclaration de conformit CE

    3

    7 Autres caractristiques techniques7.1 Eau de chauffage dans lappareil protge du gel 4

    4. Le circulateur de chauffage et le rgulateur de la pompe chaleur doivent toujours tre prts fonctionner.

    Oui Oui

    7.2 Niveaux de puissance 1 1

    7.3 Rgulateur interne / externe interne interneF-7

  • www.dimplex.de A-I

    Anh

    ang

    App

    endi

    x A

    nnex

    es

    Anhang / Appendix / Annexes1 Mabild / Dimension Drawing / Schma cot ............................................................................ A-II

    2 Diagramme / Diagrams / Diagrammes....................................................................................... A-III2.1 Kennlinien / Characteristic Curves / Courbes caractristiques WI 9ME ................................................A-III2.2 Kennlinien / Characteristic Curves / Courbes caractristiques WI 14ME ..............................................A-IV

    3 Stromlaufplne / Circuit Diagrams / Schmas lectriques....................................................... A-V3.1 Steuerung / Control / Commande ...........................................................................................................A-V3.2 Last / Load / Charge ..............................................................................................................................A-VI3.3 Klemmenanschlussplan / Terminal Connection Plan / Schma de connexion des bornes ..................A-VII3.4 Legende / Legend / Lgende...............................................................................................................A-VIII

    4 Hydraulisches Prinzipschema / Hydraulic Plumbing Diagram / Schma hydraulique ......... A-IX4.1 Darstellung / Schematic View / Reprsentation.....................................................................................A-IX4.2 Legende / Legend / Lgende..................................................................................................................A-X

    5 Konformittserklrung / Declaration of Conformity / Dclaration de conformit ................. A-XI

  • Anhang A

    ppendix Annexes

    11 Mabild / Dimension Drawing / Schma cot

    +HL]XQJ5FNODXI

    (LQJDQJLQ:

    lUPHSXP

    SH+HDWLQJZDWHUUHWXUQIORZ

    +HDWSXP

    SLQOHW

    5HWRXUHDXGHFKDXIIDJH

    HQWUpHGDQVOD3$&

    :lUPHTXHOOH9RUODXI

    $XVJDQJDXV:

    lUPHSXP

    SH+HDWVRXUFHIORZ

    +HDWSXP

    SRXWOHW

    6RUWLHVRXUFHGHFKDOHXU

    +HL]XQJVVHLWLJH$QVFKOVVH

    :,0

    (

    $XHQJHZLQGH

    :lUPHTXHOOHQVHLWLJH$QVFKOVVH

    :,0

    (

    $XHQJHZLQGH :

    DVVHUILOWHUP

    LW

    $XHQJHZLQGH

    &RQQHFWLRQVRQWKHKHDWLQJVLGH

    :,0

    (

    H[WHUQDOWKUHDG

    &RQQHFWLRQVRQWKHKHDWVRXUFHVLGH

    :,0

    (

    H[WHUQDOWKUHDG

    :DWHUILOWHUZ

    LWKH[WHUQDOWKUHDG

    5DFFRUGVF{WpFKDXIIDJH

    :,0

    (

    )LOHWDJHH[WpULHXU

    5DFFRUGVF{WpVRXUFHGHFKDOHXU

    :,0

    (

    )LOHWDJHH[WpULHXU

    )LOWUHjHDXDYHFILOHWDJHH[W

    :lUPHTXHOOH5FNODXI

    (LQJDQJLQ:

    lUPHSXP

    SH+HDWVRXUFHUHWXUQIORZ

    +HDWSXP

    SLQOHW

    (QWUpHVRXUFHGHFKDOHXU

    +HL]XQJ9RUODXI

    $XVJDQJDXV:

    lUPHSXP

    SH+HDWLQJZDWHUIORZ

    +HDWSXP

    SRXWOHW

    $OOHUHDXGHFKDXIIDJH

    VRUWLHGHOD3$&

    PLWPRQWLHUWHP:

    DVVHUILOWHU

    :LWKPRXQWHGZDWHUILOWHU

    DYHFILOWUHjHDXSUpP

    RQWp

    FD$SSUR[HQY

    FD$SSUR[HQYA-II

  • Anh

    ang

    App

    endi

    x A

    nnex

    es

    2.12 Diagramme / Diagrams / Diagrammes

    2.1 Kennlinien / Characteristic Curves / Courbes caractristiques WI 9ME+HL]OHLVWXQJLQ>N:@+HDWLQJFDSDFLW\LQ>N:@3XLVVDQFHGHFKDXIIDJHHQ>N:@

    :DVVHUDXVWULWWVWHPSHUDWXULQ>&@:DWHURXWOHWWHPSHUDWXUHLQ>&@

    7HPSpUDWXUHGHVRUWLHGHOHDXHQ>&@

    .DOWZDVVHUHLQWULWWVWHPSHUDWXULQ>&@&ROGZDWHULQOHWWHPSHUDWXUHLQ>&@7HPSpUDWXUHGHQWUpHGHDXIURLGHHQ>&@

    /HLVWXQJVDXIQDKPHLQFO3XPSHQOHLVWXQJVDQWHLO3RZHUFRQVXPSWLRQLQFOSRZHULQSXWWRSXPS&RQVRPPDWLRQGHSXLVVDQFH\FRPSULVSDUWGHFRQVRPPDWLRQGHODSRPSH

    'UXFNYHUOXVWLQ>3D@3UHVVXUHORVVLQ>3D@3HUWHGHSUHVVLRQHQ>3D@

    .DOWZDVVHUHLQWULWWVWHPSHUDWXULQ>&@&ROGZDWHULQOHWWHPSHUDWXUHLQ>&@

    7HPSpUDWXUHGHQWUpHGHDXIURLGHHQ>&@

    .DOWZDVVHUGXUFKIOXVVLQ>PK@&ROGZDWHUIORZUDWHLQ>PK@'pELWGHDXIURLGHHQ>PK@

    %HGLQJXQJHQ&RQGLWLRQV&RQGLWLRQV+HL]ZDVVHUGXUFKVDW]+HDWLQJZDWHUIORZUDWH'pELWGHDXGHFKDXIIDJH.DOWZDVVHUGXUFKVDW]&ROGZDWHUIORZUDWH'pELWGHDXIURLGH

    PK

    PK

    'UXFNYHUOXVWLQ>3D@3UHVVXUHORVVLQ>3D@3HUWHGHSUHVVLRQHQ>3D@

    /HLVWXQJV]DKOLQFO3XPSHQOHLVWXQJVDQWHLO&RHIILFLHQWRISHUIRUPDQFHLQFOSRZHULQSXWWRSXPS&RHIILFLHQWGHSHUIRUPDQFH\FRPSULVSDUWGHFRQVRPPDWLRQGHODSRPSH

    9HUIOVVLJHU&RQGHQVHU&RQGHQVHXU

    9HUGDPSIHU(YDSRUDWRU(YDSRUDWHXUwww.dimplex.de A-III

  • Anhang A

    ppendix Annexes

    2.22.2 Kennlinien / Characteristic Curves / Courbes caractristiques WI 14ME+HL]OHLVWXQJLQ>N:@+HDWLQJFDSDFLW\LQ>N:@3XLVVDQFHGHFKDXIIDJHHQ>N:@

    :DVVHUDXVWULWWVWHPSHUDWXULQ>&@:DWHURXWOHWWHPSHUDWXUHLQ>&@

    7HPSpUDWXUHGHVRUWLHGHOHDXHQ>&@

    .DOWZDVVHUHLQWULWWVWHPSHUDWXULQ>&@&ROGZDWHULQOHWWHPSHUDWXUHLQ>&@7HPSpUDWXUHGHQWUpHGHDXIURLGHHQ>&@

    /HLVWXQJVDXIQDKPHLQFO3XPSHQOHLVWXQJVDQWHLO3RZHUFRQVXPSWLRQLQFOSRZHULQSXWWRSXPS&RQVRPPDWLRQGHSXLVVDQFH\FRPSULVSDUWGHFRQVRPPDWLRQGHODSRPSH

    'UXFNYHUOXVWLQ>3D@3UHVVXUHORVVLQ>3D@3HUWHGHSUHVVLRQHQ>3D@

    'UXFNYHUOXVWLQ>3D@3UHVVXUHORVVLQ>3D@3HUWHGHSUHVVLRQHQ>3D@

    .DOWZDVVHUHLQWULWWVWHPSHUDWXULQ>&@&ROGZDWHULQOHWWHPSHUDWXUHLQ>&@

    7HPSpUDWXUHGHQWUpHGHDXIURLGHHQ>&@

    .DOWZDVVHUGXUFKIOXVVLQ>PK@&ROGZDWHUIORZUDWHLQ>PK@'pELWGHDXIURLGHHQ>PK@

    /HLVWXQJV]DKOLQFO3XPSHQOHLVWXQJVDQWHLO&RHIILFLHQWRISHUIRUPDQFHLQFOSRZHULQSXWWRSXPS&RHIILFLHQWGHSHUIRUPDQFH\FRPSULVSDUWGHFRQVRPPDWLRQGHODSRPSH

    .DOWZDVVHUHLQWULWWVWHPSHUDWXULQ>&@&ROGZDWHULQOHWWHPSHUDWXUHLQ>&@

    7HPSpUDWXUHGHQWUpHGHDXIURLGHHQ>&@

    +HL]ZDVVHUGXUFKIOXVVLQ>PK@+HDWLQJZDWHUIORZUDWHLQ>PK@

    'pELWGHDXGHFKDXIIDJHHQ>PK@

    %HGLQJXQJHQ&RQGLWLRQV&RQGLWLRQV+HL]ZDVVHUGXUFKVDW]+HDWLQJZDWHUIORZUDWH'pELWGHDXGHFKDXIIDJH.DOWZDVVHUGXUFKVDW]&ROGZDWHUIORZUDWH'pELWGHDXIURLGH

    PK

    PK

    9HUGDPSIHU(YDSRUDWRU(YDSRUDWHXU

    9HUIOVVLJHU&RQGHQVHU&RQGHQVHXUA-IV

  • Anh

    ang

    App

    endi

    x A

    nnex

    es

    3.13 Stromlaufplne / Circuit Diagrams / Schmas lectriques

    3.1 Steuerung / Control / Commande

    1HW]0

    DLQV5pVHDXwww.dimplex.de A-V

  • Anhang A

    ppendix Annexes

    3.23.2 Last / Load / Charge

    :3+33$

    &*UXQGIRV

    :,0(63$

    :,0

    (63$A-VI

  • Anh

    ang

    App

    endi

    x A

    nnex

    es

    3.33.3 Klemmenanschlussplan / Terminal Connection Plan / Schma de connexion des bornes

    1HW]0

    DLQV5pVHDX

    ZHUNVVHLWLJYHUGUDKWHW

    :LUHGUHDG\IRUXVH

    &kEOpHQXVLQH

    EDXVHLWVEHL%HGDUIDQ]XVFKOLHHQ

    7REHFRQQHFWHGE\WKHFXVWRP

    HUDVUHTXLUHG

    $UDFFRUGHUVLQpFHVVDLUHSDUOHFOLHQW

    1HW]/DVW0DLQV/RDG5

    pVHDX&KDUJH

    .RQWDNWRIIHQ :3JHVSHUUW

    &RQWDFWRSHQ +3GLVDEOHG

    &RQWDFWRXYHUW 3$&EORTXpH

    'LH)XQNWLRQYRQ(LVWZ

    lKOEDU

    7KHIXQFWLRQRI(FDQEHVHOHFWHG

    /DIRQFWLRQGX(SHXWrWUHVpOHFWLRQQpH

    WHU6SHUUHLQJDQJ

    .RQWDNWRIIHQ :3JHVSHUUW

    %UFNH$EHL%HGDUIHQWIHUQHQ

    QG GLVDEOHLQSXW

    &RQWDFWRSHQ +3GLVDEOHG

    5HP

    RYHEULGJH$DFFRUGLQJWRQHHG

    qPH HQWUpHHGHFRXSXUH

    &RQWDFWRXYHUW 3$&EORTXpH

    5HWLUHUOHSRQW$VLQpFHVVDLUH

    RGHURURXwww.dimplex.de A-VII

  • Anhang A

    ppendix Annexes

    3.43.4 Legende / Legend / LgendeA1 Drahtbrcke, muss eingelegt werden, wenn kein

    Sperrschtz bentigt wirdWire jumper, must be inserted if no blocking con-tactor is required

    Le cavalier fil doit tre insr en absence de dis-joncteur de blocage du fournisseur d'nergie

    A2 Drahtbrcke, muss bei Verwendung des 2ten Sper-reinganges entfernt werden

    Wire jumper, must be removed if the 2nd disable contactor is used

    Cavalier fil retirer si la 2e entre de coupure est utilise

    A4 Drahtbrcke, muss bei Einsatz eines Motorschutz-kontaktes, fr den Verdichter, entfernt werdenOffene Drahtbrcken oder Kontakte bedeuten Sperre oder Strung

    Wire jumper, must be removed if a motor protection contact is used for the compressorOpen wire jumpers or contacts mean: block or fault

    Retirer le cavalier fil si utilisation dun contact de disjoncteur de moteur, pour le compresseurCavaliers fil ou contacts ouverts signifient cou-pure ou panne

    B2* Pressostat Niederdruck-Sole Pressostat low pressure, brine Pressostat basse pression eau glycoleB3* Thermostat Warmwasser Hot water thermostat Thermostat eau chaudeB4* Thermostat Schwimmbadwasser Swimming pool water thermostat Thermostat eau de piscineC1 Betriebskondensator Verdichter Running capacitor, compressor Condensateur de service - compresseurF1 Steuersicherung im Regler Control fuse in the controller Scurit de commande intgre au rgulateurF2 Lastsicherung fr N1-Relaisausgnge an J12 und

    J13 4,0 ATrLoad fuse for N1 relay outputs at J12 and J13 4.0 slow-acting

    Coupe-circuit de charge pour sorties de relais en J12 et J13 4,0 ATr

    F3 Lastsicherung fr N1-Relaisausgnge an J15 bis J18 4,0 ATr

    Load fuse for N1 relay outputs at J15 to J18 4.0 slow-acting

    Coupe-circuit de charge pour sorties de relais en J15 jusqu J18 4,0 ATr

    F4 Pressostat Hochdruck High-pressure switch Pressostat haute pressionF5 Pressostat Niederdruck Low-pressure switch Pressostat basse pression J1...J18 Klemmensteckverbinder an N1 Terminal connector at N1 Connecteur bornes sur N1K5 Schtz Primrpumpe M11 Contactor for primary pump M11 Contacteur pompe primaire M11K11* Elektron. Relais fr Strfernanzeige Electron. remote fault indicator relay Relais pour tldtection de pannes K12* Elektron. Relais fr Schweimmbadwasserumwlz-

    pumpeElectron. relay for swimming pool water circulatingpump

    Relais pour circulateur deau de piscine

    K20* Schtz 2. Wrmeerzeuger (Heizkessel oder Tauch-heizkrper)

    Contactor, suppl. heating system (boiler or electricheating element)

    Contacteur 2me gnrateur de chaleur (chaudire ou cartouche chauffante lectr.)

    K21* Schtz Elekt. Flanschheizkrper Warmwassesr Contactor for elect. flange heater for domestic hotwater

    Contacteur corps de chauffe bride lect. eauchaude

    K22* EVU-Sperrschtz Utility blocking contactor Contacteur de coupure du fournisseur d'nergieK23* SPR-Hilfsrelais SPR auxiliary relay Relais auxiliaire SPR K25 Startrelais fr N7 Starting relay for N7 Relais de dmarrage pour N7M1 Verdichter Compressor CompresseurM11* Primrpumpe Primary pump Pompe primaireM13* Heizungsumwlzpumpe Heat circulating pump Circulateur de chauffageM15* Heizkreisumwlzpumpe - 2. Heizkreis Heat circulating pump - 2nd heating circuit Circulateur de chauffage - 2e circulateur circuitM16* Zusatzumwlzpumpe Auxiliary circulating pump Circulateur supplmentaireM18* Warmwasser-Ladepumpe Hot water loading pump Pompe de suralimentation d'eau chaudeM19* Schwimmbadwasserumwlzpumpe Swimming pool water circulating pu