alpha innotec WZSV 122K3M 10073741 XL 44 - 12 kW 12 kW 12 kW dB dB

Transcript of XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated...

Page 1: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

alpha innotec WZSV 122K3M10073741

XL

44

-

12 kW12 kW

12 kWdB

dB

Page 2: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

alpha innotec WZSV 122K3M10073741

XL

XL

Page 3: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

package (heat pumps and combination heater with heat pump)

Seasonal space heating energy efficiency of heat pump (ηs) 157 %Rated heat output of the heat pump (Prated kW) 12,4

Temperature control Class VI (Table 1) + 4 %

Supplementary boiler

package with hot water storage tank no Psup kW (rated heat output of supplementary heater)

ησ % (συπ)

( ηs % (sup) - ) x (αWP) = - %

(αWE: see Table 3) (αWE)

solar contribution (AKoll m²) (ηKoll %)

(VSp m³) (standstill heat loss of the hot water storage tank in W)

(ηSp: Table 2)

((294/Prated x11) x (AKoll m²) + (115/Prated x11) x (VSp m3)) x 0,45 x ((ηKoll %) /100) x (ηSp) = + %

Seasonal space heating energy efficiency of package 161 %rounded to thenearest integer

Seasonal space heating energy efficiency class of package

X

< 30 % ≥ 30 % ≥ 34 % ≥ 36 % ≥ 75 % ≥ 82 % ≥ 90 % ≥ 98 % ≥ 125 % ≥ 150 %

Seasonal space heating energy efficiency under colder or warmer climate conditionsSeasonal space heating energy efficiency of the heat pump (ηs) under colder climate conditions 162 %Seasonal space heating energy efficiency of the heat pump (ηs) under warmer climate conditions 158 %

colder 161 -V -5 = 166 warmer 161 +VI 1 = 162

Page 4: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

heatpump datasheet:

manufacturer: alpha innotecmodel: WZSV 122K3M

Information concerning energy efficiency class and rated heat output:load profile water heating XL -

average / low average / mediumenergy efficiency class space heater: A++ A++ -energy efficiency class waterheating A -rated heat output: 11,6 12,4 kWannual final energy consumption space heater 4582 6213 kWhannual electricity consumption waterheating 1712 kWhenergy efficiency space heater: 201 157 %energy efficiency waterheating 98 %

sound power level indoors 44 dB

special precautions concerning assembly, installation or maintenance0

additional information low mediumrated heat output colder climate 11,6 12,4 kWrated heat output warmer climate 11,6 12,4 kWannual energy consumption space heater colder climate 5293 7173 kWhannual energy consumption space heater warmer climate 2928 3999 kWhann. Electricity consumption waterheating colder climate 1712 kWhann. Electricity consumption waterheating warmer climate 1712 kWhenergy effiency space heater colder climate 208 162 %energy effiency space heater warmer climate 204 158 %energy efficiency waterheating colder climate 98 %energy efficiency DHWwarmer climate 98 %

sound power level outdoors - dB

technical data of the temperature controller

manufacturer: alpha innotecmodel: Luxtronik 2.1

controller class VI -contribution of the controller to the energy efficiency space heater 4 %

Page 5: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

Model WZSV 122K3MAir-to-water heat pump: (yes/no) noBrine-to-water heat pump: (yes/no) yesWater-to-water heat pump: (yes/no) noLow-temperature heat pump: (yes/no) noEquipped with supplementary heater: (yes/no) yescombination heater with: (yes/no) yesapplication: (low/medium) mediumclimate: (colder/average/warmer) averageItem Symbol Value Unit Item Symbol Value UnitRated heat output Prated 12 kW Seasonal space heating

energy efficiencyηS 157,0 %

Declared coefficient of performance for part load at indoortemperature 20°C and outdoor temperature Tj

Declared coefficient of performance for part load at indoortemperature 20°C and outdoor temperature Tj

Tj = -7°C Pdh 11,1 kW Tj = -7°C COPd 3,18 -Tj = +2°C Pdh 6,8 kW Tj = +2°C COPd 4,12 -Tj = +7°C Pdh 4,4 kW Tj = +7°C COPd 4,67 -Tj = +12°C Pdh 2,6 kW Tj = +12°C COPd 5,06 -Tj = bivalent temperature Pdh 12,3 kW Tj = bivalent temperature COPd 2,91 -Tj = operation limit temperature Pdh 12,3 kW Tj = operation limit temperature COPd 2,91 -For air-to-water heat pumps: Tj= +15°C (if TOL < -20°C)

Pdh - kW For air-to-water heat pumps: Tj= +15°C (if TOL < -20°C)

COPd - -

Bivalent temperature Tbiv -10 °C For air-to-water heat pumps:Operation limit temperature

TOL -10 °C

Cycling interval capacity forheating

Pcych - kW Cycling interval efficiency COPcyc - -

Degradation co-efficient (**) Cdh 1,0 - Heating water operating limittemperature

WTOL 65 °C

Power consumption in modes other than active mode Supplementary heaterOff mode POFF 0,005 kW Rated heat output Psup 0,1 kWThermostat-off mode PTO 0,015 kW Type of energy input electricalStandby mode PSB 0,007 kWCrankcase heater mode PCK - kWOther itemsCapacity control fixed For air-to-water heat pumps:

Rated air flow rate, outdoors- - m3/h

sound power level,indoors/outdoors

LWA 44 / - dB For water-/brine-to-water heatpumps: Rated brine or waterflow rate, outdoor heatexchanger

- 1.460 m3/h

Emissions of nitrogen oxides NOX - mg/kWhFor heat pump combination heater:Declared load profile XL Water heating energy efficiency ηwh 98 %Daily electricity consumption Qelec 5,000 kWh Daily fuel consumption Qfuel - kWhContact details ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heatingPdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.

Page 6: XL - alpha- · PDF fileDeclared load profile XL Water heating energy efficiency ... the rated heat output Prated is equal to the design load for heating ... outdoor heat exchanger

Model WZSV 122K3MAir-to-water heat pump: (yes/no) noBrine-to-water heat pump: (yes/no) yesWater-to-water heat pump: (yes/no) noLow-temperature heat pump: (yes/no) noEquipped with supplementary heater: (yes/no) yescombination heater with: (yes/no) yesapplication: (low/medium) lowclimate: (colder/average/warmer) averageItem Symbol Value Unit Item Symbol Value UnitRated heat output Prated 12 kW Seasonal space heating

energy efficiencyηS 201,0 %

Declared coefficient of performance for part load at indoortemperature 20°C and outdoor temperature Tj

Declared coefficient of performance for part load at indoortemperature 20°C and outdoor temperature Tj

Tj = -7°C Pdh 10,3 kW Tj = -7°C COPd 4,52 -Tj = +2°C Pdh 6,3 kW Tj = +2°C COPd 5,27 -Tj = +7°C Pdh 4,1 kW Tj = +7°C COPd 5,60 -Tj = +12°C Pdh 2,7 kW Tj = +12°C COPd 5,78 -Tj = bivalent temperature Pdh 11,5 kW Tj = bivalent temperature COPd 4,26 -Tj = operation limit temperature Pdh 11,5 kW Tj = operation limit temperature COPd 4,26 -For air-to-water heat pumps: Tj= +15°C (if TOL < -20°C)

Pdh - kW For air-to-water heat pumps: Tj= +15°C (if TOL < -20°C)

COPd - -

Bivalent temperature Tbiv -10 °C For air-to-water heat pumps:Operation limit temperature

TOL -10 °C

Cycling interval capacity forheating

Pcych - kW Cycling interval efficiency COPcyc - -

Degradation co-efficient (**) Cdh 1,0 - Heating water operating limittemperature

WTOL 65 °C

Power consumption in modes other than active mode Supplementary heaterOff mode POFF 0,005 kW Rated heat output Psup 0,1 kWThermostat-off mode PTO 0,015 kW Type of energy input electricalStandby mode PSB 0,007 kWCrankcase heater mode PCK - kWOther itemsCapacity control fixed For air-to-water heat pumps:

Rated air flow rate, outdoors- - m3/h

sound power level,indoors/outdoors

LWA 44 / - dB For water-/brine-to-water heatpumps: Rated brine or waterflow rate, outdoor heatexchanger

- 1.460 m3/h

Emissions of nitrogen oxides NOX - mg/kWhFor heat pump combination heater:Declared load profile XL Water heating energy efficiency ηwh 98 %Daily electricity consumption Qelec - kWh Daily fuel consumption Qfuel - kWhContact details ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heatingPdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.