Valencia - Honeywell...Valencia UK Head Office Honeywell Control Systems Ltd. Honeywell House...
Embed Size (px)
Transcript of Valencia - Honeywell...Valencia UK Head Office Honeywell Control Systems Ltd. Honeywell House...
-
Honeywell Subject to change EN2H-2039GE25 R0514
5008
8832
-001
Rev
. A
Thermostatic Radiator Valves - Installer Guide
Information Optional Fittings 2 - 130°C (36 - 266°F)Max. 10bar (145psi)Δpmax = 1.0bar (14.5psi)
DN15 angle kv = 1.57 m3/hDN15 straight kv = 0.87 m3/hDN10 - 90% kvDN8 - 70% kvM30x1.5
ModelsVT200 VT117 VTL120 VTL200 VHL120 VTL120 - 15A - DP
P - PushfitD - Drain-offA - AngleS - StraightPipe DiameterDN8, DN10, DN15
Installing
Drain-off Pushfit
S
S
A
A
α = 90°
10m
m
Integrated Balancing InsertValencia TRVs can be balanced using either the Integrated Balancing Insert or the Lockshield Valve.
To understand the benefits of using the Integrated Balancing Insert, please visit the TRV section in www.honeywelluk.com
12
34
5 6 7
89
011
Valencia
-
UK Head OfficeHoneywell Control Systems Ltd.Honeywell HouseSkimped Hill RoadBracknell, Berkshire RG12 1EBT (0 13 44) 65 60 00F (0 13 44) 65 62 40www.honeywelluk.com
EN2H-2039GE23 R0514April 2014© 2014 Honeywell International Inc.Subject to change without noticeManufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland or its authorized representative.
Thermostatic Radiator Valves - Homeowner GuideWhat is a thermostatic radiator valve (TRV) Thermostatic Radiator Valves sense the air temperature around them and control the flow of water through the radiator which they are fitted to.• TRVs limit the temperature within each room and do not directly control the boiler, the boiler is switched by other controls such as Timers,
Programmers, etc• Turning a TRV to a higher setting will not make the room heat up any faster because this depends upon the boiler size and setting and the radiator
size.• UK Building regulations recommend a TRV to be fitted in each room except the one with the Room Thermostat• To save Energy, turn each TRV only to a setting which is appropriate to its use.• TRVs need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture.• For a clear understanding of your heating controls and how they work, ask your installer or visit the Homeowner section of
www.honeywelluk.com
Honeywell ‘A’ Rated for Efficiency Typical Home Energy useHoneywell TRVs meet the highest standards of energy efficiency and will significantly reduce the energy used by your heating system when used correctly.
Heating: 60%Hot Water: 24%Lightning: 3%Cooking: 3%Electrical Appliances: 3%Other: 7%
How to use
closed 6°C 8°C 12°C 16°C 20°C 23°C 26°CVT117 / VTL120 0 ❄ 1 2 3 • 5 6VT200 / VTL200 N/A ❄ 1 2 3 • 5 6
Adjust the TRV setting by turning the TRV head to the appropriate position
Upgrading your existing TRVs ?
Want to change the style to match your décor ?Thinking of upgrading to a wireless Zoning system ?
Then please visit the TRV section of www.honeywelluk.com for more information
ABCDEF
011
Valencia
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice