NEW PRODUCTS ΑIΑ-600 automated immunoassay ana- lyzer is designed for the measurement of tumor markers, proteins, and thyroid and other hormones in serum samples. The system is based on enzyme immuno- assay technology. Tosoh Medics 401 TLC. ScanDuet TLC radioimaging and analysis system, which consists of two automated scanners directed by a single multitasking computer, loads and reads up to eight 20 X 20 cm plates without operator intervention. Fifty dpm of 3 H or I4 C can be measured in 10 min. Bioscan 404 Spectrophotometer. Model U-4001 UV-vis-near-IR double-monochroma- tor, double-beam recording spectro- photometer, designed primarily for use with solid samples, features a large sample compartment that allows the analysis of semiconductor wafers, spe- cial optics, glass films, and coatings. Hitachi 405 IR. RS-1250 is a modular near-IR re- cording spectrophotometer with a wavelength range of 750-1700 nm and a resolution of 1.5 nm. The optical module incorporates a scanning digital monochromator, germanium detector, 20 W source, and a sample compart- ment with 90° and 180° detector ports. Optometries 406 Viscometer. VT501 features a built-in microprocessor for monitoring and dis- play of viscosity, shear rate, tempera- ture, torque, and speed. Applications include the testing of oils, polymer so- lutions, slurries, paints, inks, lotions, creams, and foods. Haake, Fisons In- struments 407 EPR/ESR. Model 8300 EPR/ESR spectrometer features a Hall-effect probe that provides field regulation of ±4 ppm over the 250-6000 G magnetic field range. The solid-state microwave source is tunable from 9.1 to 9.9 GHz. Micro-Now Instrument Co. 408 Oil analysis. MOA-M multielement oil analyzer, designed primarily for lab- oratory rather than field applications, incorporates 30 channels and an IBM PS/2 computer. The system is intend- ed for the analysis of used oils, hydrau- lics, and fuels. Baird 409 LC detector. Model LC-304 fluores- cence detector features two holograph- ic grating monochromators and a 2-nm-pathlength flow cell that is ex- ternal to the unit. The instrument design eliminates the need for dark current correction. Linear Instruments 410 Distillation. Single effect deluxe Os- mostill, which provides 1 Mohm-cm pyrogen-free ultrapure water for a vari- ety of laboratory applications, features fully automatic controls that allow con- tinuous 24-h operation. A resistivity meter is used to monitor final distillate quality. Osmonics 411 FIA/IC. QuikChem automated ion an- alyzer incorporates both flow injection analysis and ion chromatography. The system can be used to profile environ- mental samples for basic anions, alkali metals, alkaline earths, and transition metals. Lachat Instruments 412 Oxygen. Model 3160 trace oxygen ana- lyzer features full-scale accuracy of ±2%, four measurement ranges, autho- rization entry code to prevent tamper- ing, automatic electronic zero, and user-selectable analog or digital out- puts. Atmospheric air can be used for calibration. Teledyne Analytical In- struments 413 Software Curve fitting. TableCurve performs one-pass least-squares curve fitting to 221 candidate equations. Equations are ranked by r 2 coefficients; the user can examine graphically any equation and can view standard errors, the F-statistic, and prediction/confidence tables. Jandel Scientific 415 Assays. Autoassay is a set of five com- puter programs designed to record measurements and perform calcula- tions for agar diffusion assays. Includ- ed is software for quantitative analysis and screening. Giles Scientific 416 Manufacturers' Literature AA. Brochure highlights the Spec- trAA-5 atomic absorption spectrome- ter, which allows measurements to be made in absorbance, concentration, or emission modes. 4 pp. Varian Asso- ciates 417 Temperature. Application note de- scribes thermocouples and their use in temperature measurement. Basic con- cepts, experimental cases, sources of measurement errors, and error minimi- zation techniques are discussed. 21 pp. National Instruments 418 Newsletter. Biotext, Vol. 3, No. 2, in- cludes information on a capillary col- umn for determination of fish oil fatty acid methyl esters and on analysis of biological fluids for diuretic and anti- inflammatory drugs. 16 pp. Supelco 419 LC. Brochure highlights the Integral 4000 liquid chromatograph, which fea- tures a built-in four-solvent pump, 109-position random access auto- sampler, diode array detector, column oven, and data manipulation software. 18 pp. Perkin-Elmer 420 Vitamins. Application note discusses the spectrophotometric determination of vitamin Ε in blood serum. Appara- tus, reagents, and procedures are de- scribed. Beckman Instruments 421 Concentrator. Brochure describes the RC10.22 microprocessor-controlled centrifugal vacuum concentrator, which combines centrifugal force to prevent bumping and foaming with high vacuum and heat to remove sol- vent. Jouan 422 For more information on listed items, circle the appropriate numbers on one of our Readers' Service Cards 1066 A · ANALYTICAL CHEMISTRY, VOL. 62, NO. 20, OCTOBER 15, 1990

Transcript of Software

NEW PRODUCTS

ΑIΑ-600 automated immunoassay ana­lyzer is designed for the measurement of tumor markers, proteins, and thyroid and other hormones in serum samples. The system is based on enzyme immuno­assay technology. Tosoh Medics 401

TLC. ScanDuet TLC radioimaging and analysis system, which consists of two automated scanners directed by a single multitasking computer, loads and reads up to eight 20 X 20 cm plates without operator intervention. Fifty dpm of 3H or I4C can be measured in 10 min. Bioscan 404

Spectrophotometer. Model U-4001 UV-vis-near-IR double-monochroma-tor, double-beam recording spectro­photometer, designed primarily for use with solid samples, features a large sample compartment that allows the analysis of semiconductor wafers, spe­cial optics, glass films, and coatings. Hitachi 405

IR. RS-1250 is a modular near-IR re­cording spectrophotometer with a wavelength range of 750-1700 nm and a resolution of 1.5 nm. The optical module incorporates a scanning digital monochromator, germanium detector, 20 W source, and a sample compart­ment with 90° and 180° detector ports. Optometries 406

Viscometer. VT501 features a built-in microprocessor for monitoring and dis­play of viscosity, shear rate, tempera­ture, torque, and speed. Applications include the testing of oils, polymer so­lutions, slurries, paints, inks, lotions, creams, and foods. Haake, Fisons In­struments 407

EPR/ESR. Model 8300 EPR/ESR spectrometer features a Hall-effect probe that provides field regulation of

±4 ppm over the 250-6000 G magnetic field range. The solid-state microwave source is tunable from 9.1 to 9.9 GHz. Micro-Now Instrument Co. 408

Oil analysis. MOA-M multielement oil analyzer, designed primarily for lab­oratory rather than field applications, incorporates 30 channels and an IBM PS/2 computer. The system is intend­ed for the analysis of used oils, hydrau­lics, and fuels. Baird 409

LC detector. Model LC-304 fluores­cence detector features two holograph­ic grating monochromators and a 2-nm-pathlength flow cell that is ex­ternal to the unit. The instrument design eliminates the need for dark current correction. Linear Instruments

410

Distillation. Single effect deluxe Os-mostill, which provides 1 Mohm-cm pyrogen-free ultrapure water for a vari­ety of laboratory applications, features fully automatic controls that allow con­tinuous 24-h operation. A resistivity meter is used to monitor final distillate quality. Osmonics 411

FIA/IC. QuikChem automated ion an­alyzer incorporates both flow injection analysis and ion chromatography. The system can be used to profile environ­mental samples for basic anions, alkali metals, alkaline earths, and transition metals. Lachat Instruments 412

Oxygen. Model 3160 trace oxygen ana­lyzer features full-scale accuracy of ±2%, four measurement ranges, autho­rization entry code to prevent tamper­ing, automatic electronic zero, and user-selectable analog or digital out­puts. Atmospheric air can be used for calibration. Teledyne Analytical In­struments 413

Software Curve fitting. TableCurve performs one-pass least-squares curve fitting to 221 candidate equations. Equations are ranked by r2 coefficients; the user can examine graphically any equation and can view standard errors, the F-statistic, and prediction/confidence tables. Jandel Scientific 415

Assays. Autoassay is a set of five com­puter programs designed to record measurements and perform calcula­tions for agar diffusion assays. Includ­ed is software for quantitative analysis and screening. Giles Scientific 416

Manufacturers' Literature AA. Brochure highlights the Spec-trAA-5 atomic absorption spectrome­ter, which allows measurements to be made in absorbance, concentration, or emission modes. 4 pp. Varian Asso­ciates 417

Temperature. Application note de­scribes thermocouples and their use in temperature measurement. Basic con­cepts, experimental cases, sources of measurement errors, and error minimi­zation techniques are discussed. 21 pp. National Instruments 418

Newsletter. Biotext, Vol. 3, No. 2, in­cludes information on a capillary col­umn for determination of fish oil fatty acid methyl esters and on analysis of biological fluids for diuretic and anti­inflammatory drugs. 16 pp. Supelco

419

LC. Brochure highlights the Integral 4000 liquid chromatograph, which fea­tures a built-in four-solvent pump, 109-position random access auto-sampler, diode array detector, column oven, and data manipulation software. 18 pp. Perkin-Elmer 420

Vitamins. Application note discusses the spectrophotometric determination of vitamin Ε in blood serum. Appara­tus, reagents, and procedures are de­scribed. Beckman Instruments 421

Concentrator. Brochure describes the RC10.22 microprocessor-controlled centrifugal vacuum concentrator, which combines centrifugal force to prevent bumping and foaming with high vacuum and heat to remove sol­vent. Jouan 422

For more information on listed items, circle the appropriate numbers on one of our Readers' Service Cards

1066 A · ANALYTICAL CHEMISTRY, VOL. 62, NO. 20, OCTOBER 15, 1990