Shimadzu Shimadzu's Promise of LC Excellence Column to Column Performance Microbore column LC cuts solvent cost by 95% while expanding plate number up to 300,000. The LC-5A system is efficiency personified with a pumping system having 1 μΙ/min to 9.9 ml/min capability. The SPD- 2AM detector has a 0.5 μΙ flow cell. Total system dead volume is about 2 μΙ. The proprietary microbore columns are available in stand- ard and reverse phase models in 25cm, 50cm and 100cm lengths which can be combined up to 1000cm without reducing efficiency. The LC-5A can be used with standard size columns as well. CIRCLE 209 ON READER SERVICE CARD SPD-2A • UV monitor for LC features 195-350 nm range, <10r 4 abs noise, <10~ 3 abs/hr drift, 10 step sensitivity selection, ±2.5 abs zero suppression, 8 μΙ (10mm path), and tempera- ture compensation. CIRCLE 210 ON READER SERVICE CARD RF-530^ Fluorescence monitor for LC system features mono- chromators for both exci- tation and emission wave- lengths, a xenon source, multiple range selections, 12 μΙ volume flow cell and compatibility to any LC system. CIRCLE 211 ON READER SERVICE CARD A C-R2A The microcomputer data processor features 2 chan- nel operation for LC and GC. Simple one key stroke operation is expanded by Basic language program capability. CIRCLE 212 ON READER SERVICE CARD Write today for more information on these and other Shimadzu instruments. SHIMADZU SCIENTIFIC INSTRUMENTS, INC. SHIMADZU SCIENTIFIC INSTRUMENTS, INC. 9147-H Red Branch Road, Columbia, Md. 21045, U.S.A. Phone: (301)997-1227 Telex: 87959 SHIMADZU (EUROPA) GmbH 4000 Dusseldorf 1, Johannes Weyer Str. 1,F.R.Germany Phone:(0211)314061 Telex: 08586839 SHIMADZU CORPORATION INTERNATIONAL MARKETING DIV. Shinjuku-Mitsui Building, 1-1, Nishishinjuku 2-chome, Shinjuku-ku, Tokyo 160, Japan. Phone: Tokyo 03-346-5641 Telex: 0232-3291 SHMDTJ.

Transcript of SHIMADZU SCIENTIFIC INSTRUMENTS, INC.

Page 1: SHIMADZU SCIENTIFIC INSTRUMENTS, INC.

Shimadzu

Shimadzu's Promise of LC Excellence

Column to Column Performance Microbore column LC cuts solvent cost by 95%

while expanding plate number up to 300,000.

The LC-5A system is efficiency personified with a pumping system having 1 μΙ/min to 9.9 ml/min capability. The SPD-2AM detector has a 0.5 μΙ flow cell. Total system dead volume is about 2 μΙ. The proprietary microbore columns are available in stand­ard and reverse phase models in 25cm, 50cm and 100cm lengths which can be combined up to 1000cm without reducing efficiency. The LC-5A can be used with standard size columns as well. CIRCLE 209 ON READER SERVICE CARD

SPD-2A • UV monitor for LC features 195-350 nm range, <10r4 abs noise, <10~3 abs/hr drift, 10 step sensitivity selection, ±2.5 abs zero suppression, 8 μΙ (10mm path), and tempera­ture compensation. CIRCLE 210 ON READER SERVICE CARD

RF-530^ Fluorescence monitor for LC system features mono-chromators for both exci­tation and emission wave­lengths, a xenon source, multiple range selections, 12 μΙ volume flow cell and compatibility to any LC system. CIRCLE 211 ON READER SERVICE CARD

A C-R2A The microcomputer data processor features 2 chan­nel operation for LC and GC. Simple one key stroke operation is expanded by Basic language program capability.

CIRCLE 212 ON READER SERVICE CARD

• Write today for more information on these and other Shimadzu instruments.

SHIMADZU SCIENTIFIC INSTRUMENTS, INC.

SHIMADZU SCIENTIFIC INSTRUMENTS, INC. 9147-H Red Branch Road, Columbia, Md. 21045, U.S.A. Phone: (301)997-1227 Telex: 87959 SHIMADZU (EUROPA) GmbH 4000 Dusseldorf 1, Johannes Weyer Str. 1,F.R.Germany Phone:(0211)314061 Telex: 08586839 SHIMADZU CORPORATION INTERNATIONAL MARKETING DIV. Shinjuku-Mitsui Building, 1-1, Nishishinjuku 2-chome, Shinjuku-ku, Tokyo 160, Japan. Phone: Tokyo 03-346-5641 Telex: 0232-3291 SHMDTJ.