GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case...

8
GRID

Transcript of GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case...

Page 1: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

GRID

Page 2: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

Externalstabilizingresistor

Externalmetrosil(if required)

N.E.R.

Externalstabilizingresistor

Externalmetrosil(if required)

28 27

28 27

MCAG 14

MCAG 14

Page 3: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

a) Mounting clip for stabilising resistor

b) Stabilising resistor

SIDE VIEW TOP VIEW14.25

10.20

25.00

8.00

16.00

7.00

21.00

M6 Clearance

32.00

29.3

216.00

19.2

28.00

SLOT 4.5

20.00

25 γ

101152

M12 ISO Stud

All dimensions in mm25.4

M6 ISO Terminals

2mm - 7mm Fixing Holes178

107

Insulating Spacer

240190 ±7

Page 4: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

100

012 3 4 5 6 7 8 9 10

50

Multiples of Pick Up

Ope

ratin

g Tim

e in

Milli

seco

nds

Page 5: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V
Page 6: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

Push buttonprojection 10 max

All dimensions in mm

Panel cut-out:Flush mounting fixing details

4 ho les ø 4 .4

Flush mounting

71

77

21232 25 min.

Reset

157 max.

73

159168

2623.5

177

Push buttonprojection 10 max

All dimensions in mm

Panel cut-out:Flush mounting fixing details

4 holes ø 4.4

Flush mounting

149

155

21232 25 min.

11

Reset

157 max.

151

159168

103.624

177

Page 7: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

Information Required with Order Relay Type MCAG 4

Number of Elements

OneThree

13

Case Size

15TE (Size 3) Case for MCAG14 only30TE (Size 6) Case for MCAG34 only

SV

Contact Wiring

Segregated contactsCommon contacts (MCAG34 only)

SC

Frequency & Flagging

50Hz 60Hz

Without Flag �

With Hand Reset Flag �

Without Flag �

With Hand Reset Flag �

ABCD

CT Secondary & Setting Range

0.5A 1A 5A

5 - 20% Setting10 - 40% Setting20 - 80% Setting50 - 200% Setting5 - 20% Setting10 - 40% Setting20 - 80% Setting50 - 200% Setting20 - 80% (A & C) / 10 - 40% (B)50 - 200% (A & C) / 20 - 80% (B)5 - 20% Setting10 - 40% Setting20 - 80% Setting

ABCDBCEFJKDFG

Stabilising Resistor

No Resistor SuppliedStandard Resistor for 0.5A CT RatingStandard Resistor for 1A CT RatingStandard Resistor for 5A CT RatingNon-standard Resistor (24 ohms)Non-standard Resistor (47 ohms)Non-standard Resistor (100 ohms)Non-standard Resistor (150 ohms)Non-standard Resistor (220 ohms)Non-standard Resistor (270 ohms)Non-standard Resistor (470 ohms)Non-standard Resistor (820 ohms)Non-standard Resistor (1000 ohms)Non-standard Resistor (1500 ohms)Non-standard Resistor (2700 ohms)Non-standard Resistor (5600 ohms)

0000000000001125

0420001122480576

0724240527720000

0007470000000000

Factory Defined

Hardware Issue Suffix

Page 8: GRID · Information Required with Order Relay Type MCAG 4 Number of Elements One Three 1 3 Case Size 15TE (Size 3) Case for MCAG14 only 30TE (Size 6) Case for MCAG34 only S V

GRID