Erratum Chapter 4 - Earth and water pressure | 26 Chapter 4.9.15. Area loads a c+d x z 45 + ϕ'/2 ϕ' q Fig. 4.3. Force distribution area lords. Piling Handbook, 9th edition (2016) Note: Corrected value in red.

Transcript of Piling Handbook, 9th edition (2016)...

Page 1: Piling Handbook, 9th edition (2016) Erratumsheetpiling.arcelormittal.com/uploads/files/AMCRPS_PHB_Erratum_11... · For example, a blanket surcharge ... of 10-20 kPa, representing

ErratumChapter 4 - Earth and water pressure | 26 Chapter 4.9.15. Area loads

a

c+d

xz

45 + ϕ'/2

ϕ'

q

Fig. 4.3. Force distribution area lords.

Piling Handbook, 9th edition (2016)

Note: Corrected value in red.

Page 2: Piling Handbook, 9th edition (2016) Erratumsheetpiling.arcelormittal.com/uploads/files/AMCRPS_PHB_Erratum_11... · For example, a blanket surcharge ... of 10-20 kPa, representing

Piling Handbook, 9th edition (2016)

5.8.3. Surcharge loads

Assessment of the relevant surcharge loading to be taken by the wall must consider the influence of nearby buildings, stockpiles, plant movements, etc. Particular attention should be given to repeated loading, e.g. from crane tracks behind quay walls, where the earth pressures induced against the wall may increase with each application of load.

It is common in the UK to design embedded retaining walls to withstand a minimum surcharge acting behind the wall. For example, a blanket surcharge of 10 kPa has traditionally been applied to walls retaining less than 3 m of soil [xii and xiii]. Highway structures have traditionally been designed for a blanket surcharge of 10-20 kPa, representing “HA” through to the heaviest “HB” loading [xiv]; and railways for a blanket surcharge of 30-50 kPa [xv]. However, Eurocode 7 - Part 1 [v] does not require a minimum surcharge to be assumed in design. Therefore earth pressures should be calculated in accordance with the methods described in Chapter 4 and surcharges applied where relevant with the appropriate partial factor for the action. Chapter 4.9.11. describes the methods to calculate various types of surcharge configurations.

ErratumChapter 5 - Design of steel sheetpile structures | 22Chapter 5.8.3. Surcharge loads

Note: Corrected value in red.

Page 3: Piling Handbook, 9th edition (2016) Erratumsheetpiling.arcelormittal.com/uploads/files/AMCRPS_PHB_Erratum_11... · For example, a blanket surcharge ... of 10-20 kPa, representing

ParameterPartialfactor

Combination

1 2

Act

ions

Permanent Unfavourable gG 1.35 1.00

Favourable gG,fav 1.00 1.00

Variable Unfavourable gQ 1.50 1.30

Favourable gQ,fav 0 0

M1 M2

Mat

eria

l pr

oper

ties

1)

Effective shearing resistance gj 1.00 1.00 1.25

Effective cohesion gc 1.00 1.00 1.25

Undrained shear strength gcu 1.00 1.00 1.40

Unconfined compressive strength gqu 1.00 1.00 1.40

Weight density gg 1.00 1.00 1.00

w/o w

Resi

stan

ce2

) Base resistance gb 1.00 1.70 1.50

Shaft resistance in compression gs 1.00 1.50 1.30

Total resistance gt 1.00 1.70 1.50

Shaft resistance in tension gs,t 1.00 2.00 1.70Table 6.1. Partial factors for design of pile foundations for ultimate limit state GEO in persistent and transient design situations.

1) In combination 2, set M1 is used for calculating resistances of piles or anchors and set M2 for calculating unfavourable actions on piles owing e.g. to negative skin friction or transverse loading. 2) Without explicit verification of SLS, the larger resistance factors apply (column w/o); with explicit verification, the smaller values apply (column w).

Note: Corrected value in red.

ErratumChapter 6 - Axially loaded steel piles | 8 Chapter 6.3.2. Design limit states

Piling Handbook, 9th edition (2016)

Page 4: Piling Handbook, 9th edition (2016) Erratumsheetpiling.arcelormittal.com/uploads/files/AMCRPS_PHB_Erratum_11... · For example, a blanket surcharge ... of 10-20 kPa, representing

7.13.4. Effects of actions

Active thrust from ground self-weight will be treated as a favourable action, according to the “single-source principle”, to match passive thrust.

Active thrust on anchor restraint:

(2

55.35

D’

kNm

=

)a,d ah G,fav v ,k Q Qk P K q D’= × × × + × ×γ σ γ

Design force to be provided to wall: Fd = 125 kN/m.

Total horizontal thrust:

HEd = Fd + Pa,d = 180.35 kN/m.

7.13.5. Resistance

Partial factor for Design Approach 1, Combination 2 from Set R1:

gR,e = 1.00

Passive earth resistance coefficient:

Kph = 2.622

Passive thrust will be treated as a favourable action, according to the “single-source principle”.

Passive thrust on anchor restraint:

,Re

2P Kmγ

266.41p d phkN

D’, ,G fav v kγ σ× ×

= × =

Total horizontal resistance:

HRd = Pp,d = 266.41 kN/m

ErratumChapter 7 - Design of anchorages and tieback systems | 27 Chapter 7.13.4. Effects of actions - Chapter 7.13.5. Resistance

Piling Handbook, 9th edition (2016)

Note: Corrected value in red.

Page 5: Piling Handbook, 9th edition (2016) Erratumsheetpiling.arcelormittal.com/uploads/files/AMCRPS_PHB_Erratum_11... · For example, a blanket surcharge ... of 10-20 kPa, representing

Piling Handbook, 9th edition (2016)

ErratumChapter 12 - Worked example | 12 Chapter 12.2.6. Earth pressure diagram

Made ground

Low strength clay

Sand & gravel

Medium strength clay

-7.2 m

GWL - 0.0 m

-2.40 m

2.40

m3.

70 m

4.90

m

-6.10 m

-11.00 m

-15.00 m

-16.00 m

-6.1 m

Typical section

0.050.0 100.0 150.0 200.0 250.0

-2.0

-4.0

-6.0

-8.0

-10.0

-12.0

-14.0

-16.0

Active pressure diagrams

γsat,d= 19.1 kN/m3

γw,d= 9.81 kN/m3φ’peak,d= 24.8°

γsat,d= 17.2 kN/m3

φ’peak,d= 16.2°

c’d= 0.0 kN/m2

γsat,d= 20.6 kN/m3

φ’peak,d= 33.9°

c’d= 0.0 kN/m2

γsat,d= 18.6kN/m3

φ’peak,d= 20.5°

c’d= 1.6kN/m2

Total

Water

Soil

38.043.314.5

19.8

35.117.5

32.348.2

23.5

59.8

107.9

147.263.7

94.977.4

140.3156.1

210.9

Fig. 12.3. Example of 2 dimensional sketch of active pressure components.

Piling Handbook, 9th edition (2016)

Note: Corrected value in red.