210Electronic manifolds incl. vacuum measurement and 1 temperature probe socket

Vacuuming a refrigeration unit

Measuring condensation temperature anddetermining subcooling

PC analysis

1 temperature socket

3 pressure sockets

38 refrigerants

3-way valve battery

Internal memory

Part no.

testo 560-1, Electronic manifold incl. vacuummeasurement and 1 temperature probe socket,brass valve block, incl. battery

0560 5601

testo 560-1

Part no.

testo 560-2, Electronic manifold incl. vacuummeasurement and 1 temperature probe socket,stainless steel valve block (also for ammonia(NH3) refrigerant), incl. battery

0560 5602

testo 560-2

IP65Vacuum measurement withaccurate vacuum sensor

testo 560, the electronic manifold for allapplications on refrigeration systems andheat pumps. The instrument with high-quality sensors to measure pressure,vacuum, temperature and a valve bank totemporarily change the flow paths in thesystem.Convenient PC software is used for datamanagement: data overviews of allmeasurements, displays in table and graphform, automatic acceptance of company,fitter, customer and system data.

Internal temperature sensor(Pt1000) + external temperatureprobe socket

Superheating, subcooling,temperature difference calculationConvenient data analysis on yournotebook/PC

Meas. rangeDescription Illustration Accuracy t99 Conn. Part no.

Suitable probes at a glance

-50... +400 °C Class A 12 s Fixed cable 0628 1272Robust, waterproof immersion/penetration probe

110 mm 30 mm

Ø 3.2 mmØ 4 mm

-50... +400 °C Class B 40 s Fixed cable 0628 1972Robust, waterproof surface probe with widenedmeasuring tip, for smooth surfaces

110 mm

Ø 9 mmØ 4 mm

-50... +400 °C Class A 70 s Fixed cable 0628 1772Robust, affordable air probe

110 mm

Ø 4 mm

0... +120 °C Class 1 90 s Fixed cable 0609 5600Pipe wrap probe with Velcro strip, for temperaturemeasurement on pipes with diameter from 6 mmto max. 120 mm, Tmax +120°C

When ordering spare probes for old acdoor instruments PCD 312, please also order adapter. Part no. available on request.

395 mm

20 mm

page_210_211_ .qxd 08.11.02 11:15 Sei e 1

Page 2: page 210 211 E - K - Test, s.r.o. ·  · 2009-06-22bar psi Pa °C °F t cu t oo ε C/L 210 Electronic manifolds incl. vacuum measurement and 1 temperature probe socket Vacuuming

Pipe wrap probe with Velcrostrip, for temperaturemeasurement on pipes withdiameter from 6 mm to max.120 mm, Tmax +120°C

PC software for data analysisand documentation

RS232 cable

Mains unit for external powersupply

Transport case (plastic)

Brass version

Stainless steel version

211

0628 0178RS232 cableCable to connect instrument to PC (1.8m) for data transfer

0628 1084Mains unit for external power supplyMains unit is recommended for long-term measurements

0516 0008Transport case (plastic)For practical storage of instrument and accessories

0520 0115ISO calibration certificate/PressureAbsolute pressure; 5 pt. distributed over the whole measurement range

0520 0001ISO calibration certificate/Temperature

0520 0212DKD calibration certificate/PressureAbsolute pressure; 11 measuring points distributed over meas. range (0.1 to 0.6% of fsv)

For air/immersion probes, calibration points -18°C; 0°C; +60°C

0520 0211DKD calibration certificate/Temperature Meas. instr. with air/immersion probe; calibration points -20°C; 0°C; +60°C

0554 5600PC software for data analysis and documentationWith data management incl. diagram and table displays

Technical data

PC software for data analysis and documentation

With data management incl. diagram and tabledisplays

0554 5600Part no.

All conventional refrigerants (see Table) are storedin the instrument, new refrigerants can be updatedfree of charge in Internet Mains unit is recommended for long-term

measurements

Mains unit for external power supply

0628 1084Part no.

Transport case (plastic)

0516 0008Part no.

Part no.Ordering data for Accessories

Practical accessories and recommended sets

bar

psi

Pa

°C

°F

tcu

too

εεC/L

Recommended kit:

testo 560, Set for refrigeration fitters

As above set, but with the following instead of testo 560-1:testo 560-2, Electronic manifold, stainless steel valve block (also forammonia (NH3) refrigerant)

testo 560-1, Electronicmanifold incl. vacuummeasurement and 1temperature probe socket,brass valve block, incl. battery

Refrigerants stored in instrument:

R 12

R 1270

R 123

R 124

R 125

R 134A

R 22

R 227

R 23

R 236fa

R 290

R 401A

R 401B

R 401C

R 402A

R 402B

R 403B

R 404A

R 407A

R 407B

R 407C

R 408A

R 409A

R 410A

R 413A

R 417A

R 500

R 502

R 507

R 508

R 600

R 600A

DI 24

DI 36

DI 44

Storage temp. -20... +60 °C

Battery type 9V block battery

Battery life 40 h

Oper. temp. -20... +60 °C

Warranty

Pressure media: CFC, fluorinated hydrocarbon,CO2, nitrogen (ammonia, testo 560-2 only)

Compensation: -10 to +50°C

Memory: 10,000 data records, logs 32,000 datarecords corresponding to 100,000 readings

Connection: 3 x 7/16" - UNF

Separating membrane: 316 L stainless steel(stainless steel, testo 560-2 only)

2 yearsAccuracy ±0.5% of f.v. (0... +50 bar)

±0.5% of f.v. (0... +200 hPa)

Resolution 0.1 bar (0... +50 bar)0.1 hPa (0... +200 hPa)

Meas. range -100... +400 °C

Overload ±75 bar

175x108.6x34.3 mmDimensions

Meas. rangePressure(abs)

0... +50 bar0... +200 hPa

± 1 digit

Temperature