Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

10
Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL Andrew Jones PEI/GEC Summer 2009

description

Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL. Andrew Jones PEI/GEC Summer 2009. Fusion, LTX, and Us. Why is it useful? How does it work? What does LTX contribute? What did I contribute to LTX?. Fusion Energy. High energy per reaction Abundant, cheap fuel Safe - PowerPoint PPT Presentation

Transcript of Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Page 1: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Magnetic Diagnostics for the Lithium Tokamak Experiment

(LTX) at PPPL

Andrew JonesPEI/GEC

Summer 2009

Page 2: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Fusion, LTX, and Us Why is it useful?

How does it work?

What does LTX contribute?

What did I contribute to LTX?

Page 3: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Fusion Energy

High energy per reaction Abundant, cheap fuel Safe Environmentally friendly Need three things:

High temperature (T) High density (n) Long confinement time (τ)

Image from www.atomicarchive.com

Page 4: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Tokamaks

Changing magnetic fluxes accelerate particles

Magnetic fields provide confinement

Toroidal geometry-- no open ends

Page 5: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

LTX

Liquid lithium-walled tokamak

Flat temperature profile

Low recycling Decreased

structural damage

Page 6: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Magnetic Diagnostics

Non-invasive sensors for data acquisition Changing magnetic fluxes cause voltage Hardware integrator circuits yield local

magnetic flux Digitizers output to computers Measured flux compared to calculated flux

for toroidally symmetric system (LRDFIT)

Page 7: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Calibration

Integrator gains vary unpredictably

Gain factors obtained via comparison of simulated to measured flux

Only reliable where model captures behavior well

Page 8: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Automation

Analyzed fit of model behavior to data Wrote calibration script to take in data from

LTX and check for regions of good behavior agreement

Calibration gain factor automatically calculated, output in readable format

Used in future to calibrate sensors via LRDFIT or new three-dimensional code

Page 9: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Made possible by

Grant from PEI/Grand Energy Challenges initiative

Princeton Plasma Physics Laboratory Robert Kaita Jon Menard Laura Berzak

Page 10: Magnetic Diagnostics for the Lithium Tokamak Experiment (LTX) at PPPL

Magnetic Diagnostics for the Lithium Tokamak Experiment

(LTX) at PPPL

Andrew JonesPEI/GEC

Summer 2009