Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U

Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U
Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U
Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U
Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U
download Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U

of 4

  • date post

    12-Aug-2020
  • Category

    Documents

  • view

    10
  • download

    0

Embed Size (px)

Transcript of Heat pump combination heater - Heat pump combination heater Outdoor EVLQ08CAV3 Indoor EHYHBH08AAV3U

  • Heat pump combination heater Outdoor EVLQ08CAV3Indoor EHYHBH08AAV3U

    Indoor unit sound power (*) [dB(A)] 42.0 Outdoor unit sound power (*) [dB(A)] 62.0

    Water heating Declared load profile - XL Energy efficiency class - A

    Space heating Energy efficiency class 55°C (High temp. app.) - Average climate (Design temperature = –10°C) Water heating Water heating energy efficiency (ηwh) [kW] 95.8

    Annual electricity consumption (AEC) [kWh] 0.00 Space heating Prated (declared heating capacity) @ –10°C [kW] 6.40

    Seasonal space heating efficiency (ηs) [%] 127

    Annual energy consumption [kWh] 4,020 off peak operation function integrated in Heat pump Y/N Colder climate (Design temperature = –22°C) Water heating Water heating energy efficiency (ηwh) [kW] 95.8

    Annual electricity consumption (AEC) [kWh] 0.00 Space heating Prated (declared heating capacity) @ –22°C [kW] 6.90

    Seasonal space heating efficiency (ηs) [%] 111

    Annual energy consumption [kWh] 5,900 Warmer climate (Design temperature = 2°C) Water heating Water heating energy efficiency (ηwh) [kW] 95.8

    Annual electricity consumption (AEC) [kWh] 0.00 Space heating Prated (declared heating capacity) @ –2°C [kW] 6.60

    Seasonal space heating efficiency (ηs) [%] 157

    Annual energy consumption [kWh] 2,130 Ecodesign technical data Product description Air-to-water heat pump Y/N Yes

    Water-to-water heat pump Y/N no Brine-to-water heat pump Y/N no Low-temperature heat pump Y/N no Equipped with a supplementary heater Y/N Yes Heat pump combination heater Y/N Yes

    Air to water unit Rated airflow (outdoor) [m3/h] 2,700 Brine/water to water unit Rated water/brine flow (outdoor H/E) [m3/h]

    Other Capacity control - Inverter Poff (Power consumption Off mode) [kW] 0.013

    Pto (Power consumption Thermostat off mode) [kW] 0.006

    Psb (Power consumption Standby mode) [kW] 0.013

    PCK (Power crankcase heater model) [kW] 0.000

    Qelec (Daily electricity consumption) [kWh] 0.00

    Qfuel (Daily fuel consumption) [kWh] 19.9

    Part load conditions space heating average climate (A) condition (-7°C) Pdh (declared heating capacity) [kW] 5.70

    COPd (declared COP) - 2.38

    Cdh (degradation coefficient) - 1.00 (B) condition (2°C) Pdh (declared heating capacity) [kW] 3.40

    COPd (declared COP) - 2.99

    Cdh (degradation coefficient) - 1.00 (C) condition (7°C) Pdh (declared heating capacity) [kW] 3.50

    COPd (declared COP) - 4.20

    Cdh (degradation coefficient) - 1.00 (D) (D) condition (12°C) Pdh (declared heating capacity) [kW] 3.30

    COPd (declared COP) - 5.82

    Cdh (degradation coefficient) - 1.00 (E) Tol (temperature operating limit) Tol (temperature operating limit) [°C] -10.0

    Pdh (declared heating capacity) [kW] 6.20

    COPd (declared COP) - 2.38

    WTOL (Heating water Operation Limit) [°C] 55.0 (F) Tbivalent temperature Tblv [°C] 2.00

    Pdh (declared heating capacity) [kW] 3.40

    COPd (declared COP) - 2.99

    Capacity of the back-up heater integrated in the unit P back-up heater (@Tdesignh: –10°C) [kW] 27.0

  • Psup back-up heater (@Tdesignh: –10°C) Supplementary capacity at P_design Psup (@Tdesignh: –10°C) [kW] 27.0

    Productfiche Details and Precautions on installation Productfiche Energylabels and Productfiches Product Fiche Data Address Line 1 Address Line 2

  • EHYHBH08AAV3U / EVLQ08CAV3

    XL

    A++ A

    6.90 kW 6.40 kW 6.60 kW42 dB

    62 dB

  • Model(s): EHYHBH08AAV3U / EVLQ08CAV3

    Air-to-water heat pump: Yes

    Water-to-water heat pump: no

    Brine-to-water heat pump: no

    Low-temperature heat pump: no

    Equipped with a supplementary heater: Yes

    Heat pump combination heater: Yes

    Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low- temperature application.

    Parameters shall be declared for average, colder and warmer climate conditions.

    Item Symbol Value Unit Item Symbol Value Unit

    Rated heat output (3) Prated 6.40 kW Seasonal space heating energy efficiency

    ηs 127 %

    Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj

    Tj = – 7 °C Pdh 5.70 kW Tj = – 7 °C COPd or PERd

    2.38 95.2

    – or %

    Tj = + 2 °C Pdh 3.40 kW Tj = + 2 °C COPd or PERd

    2.99 120

    – or %

    Tj = + 7 °C Pdh 3.50 kW Tj = + 7 °C COPd or PERd

    4.20 168

    – or %

    Tj = + 12 °C Pdh 3.30 kW Tj = + 12 °C COPd or PERd

    5.82 233

    – or %

    Tj = bivalent temperature Pdh 3.40 kW Tj = bivalent temperature COPd or PERd

    2.99 120

    – or %

    Tj = operation limit temperature Pdh 6.20 kW Tj = operation limit temperature COPd or PERd

    2.38 95.2

    – or %

    For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)

    Pdh kW For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C)

    COPd or PERd

    – or %

    Bivalent temperature Tbiv 2.00 °C For air-to-water heat pumps: Operation limit temperature

    TOL -10.0 °C

    Cycling interval capacity for heating Pcych kW Cycling interval efficiency COPcyc or PERcyc

    – or %

    Degradation co-efficient (4) Cdh 1.00 — Heating water operating limit temperature

    WTOL 55.0 °C

    Power consumption in modes other than active mode Supplementary heater

    Off mode POFF 0.013 kW Rated heat output (4) Psup 27.0 kW

    Thermostat-off mode PTO 0.006 kW Gas

    Standby mode PSB 0.013 kW Type of energy input

    Crankcase heater mode PCK 0.000 kW

    Other items Inverter

    Capacity control fixed/variable For air-to-water heat pumps: Rated air flow rate, outdoors

    — 2,700 m3/h

    Sound power level, indoors/outdoors LWA 62.0 / 42.0

    dB For water- or brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger

    — m3/h

    Annual energy consumption QHE 4,020 0.057

    kWh or GJ

    For heat pump combination heater:

    Declared load profile XL Water heating energy efficiency ηwh %

    Daily electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh

    Annual electricity consumption AEC kWh Annual fuel consumption AFC GJ

    Daikin Europe N.V. Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium

    (3) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).

    (4) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.

    productfiche-ch_hp (1) file (2) technicalfiche-ch_hp (1)