Pump Performance ME 120 Notes Portland State University Department of Mechanical Engineering ME 120: Pump performance

Transcript of Pump Performance - Portland State University

Page 1: Pump Performance - Portland State University

Pump PerformanceME 120 Notes

Portland State University

Department of Mechanical Engineering

ME 120: Pump performance

Page 2: Pump Performance - Portland State University

We made a pump, now we’ll test it.

ME 120: Pump performance page 1

Page 3: Pump Performance - Portland State University

Pump Performance

The pump converts electrical power into fluid motion.

Engineers have a common language and analytical models to describe pump performance.

In any one application these parameters may be more or less important.

Flow rate, Q

Head, h

Efficiency, η

Note that Q is also used as the symbol for heat transfer. In these slides, Q is the

volumetric flow rate with units m3/s or L/min.

ME 120: Pump performance page 2

Page 4: Pump Performance - Portland State University

Flow rate (1)

Consider the filling of a bucket from a faucet.

v is the downward fluid velocity

Time t1

v

Time t2

v

∆V

Volumetric flow rate

Q =Volume of fluid

Time interval

=∆V

t2 − t1=

∆V

∆t

∆V is the change in volume during

the time interval t2 − t1 = ∆t.

ME 120: Pump performance page 3

Page 5: Pump Performance - Portland State University

Flow rate (2)

Common units of volumetric flow rate are

SI English Engineering

m3/s ft3/s

L/min ft3/min or CFM

gal/min or GPM

ME 120: Pump performance page 4

Page 6: Pump Performance - Portland State University

Flow rate (3)

Mass flow rate

m =Mass of fluid

Time interval=

∆m

∆t

Mass and volume are related by the fluid density, ρ

density ρ =mass

volume=⇒ ∆m = ρ∆V

Therefore

m = ρQ

ME 120: Pump performance page 5

Page 7: Pump Performance - Portland State University

Flow rate in a tube

Consider flow from a faucet into a bucket.

The average fluid velocity is v.

In time ∆t, the fluid slug moves L = v∆t.

Therefore, the volume passing an arbitrary

reference point is

∆V = LA = v∆t A

where A is the cross-sectional area of the pipe.

Therefore, the volumetric flow rate is

Q =∆V

∆t=v∆t A

∆t= vA

v

∆V

∆V

L = v∆t

ME 120: Pump performance page 6

Page 8: Pump Performance - Portland State University

Flow rate formulas

Volumetric Flow Rate

Q = vA

where v is the average fluid velocity in the tube,

and A is the cross-section area of the tube.

Mass flow rate

m = ρQ = ρvA

where ρ is the fluid density.

If m is known, then the average velocity is

v =Q

A=m

ρA

ME 120: Pump performance page 7

Page 9: Pump Performance - Portland State University

Pump head

Head is a measure of how high the pump can

push the fluid. In the performance test, we

increase h by raising the outlet end of the tube.

If the friction losses in the inlet and outlet tubes

can be neglected, the head produced by the

pump is equal to h, the height of the free end of

the hose above the free surface of the supply

reservoir.

Each pump has a characteristic relationship

between head and flow rate.

• Q decreases when h increases

• There is a maximum h for which Q = 0

• At h = 0 (no uphill), Q is a maximum

h

ME 120: Pump performance page 8

Page 10: Pump Performance - Portland State University

Pump Curve

Procedure

1. Measure Q with the outlet tube

held at different h.

2. Plot h = f(Q)

3. Obtain a least squares curve fit

to h = f(Q).

h

Q

Maximum head

at Q = 0

Maximum flow rate

at h = 0

ME 120: Pump performance page 9

Page 11: Pump Performance - Portland State University

Pump Efficiency (1)

Each pump has an optimal operating point, i.e., a point (Q, h) that yields maximum

efficiency. In most engineering applications, there are several pumps that can supply the

desired flow rate at the necessary head. Given a choice of pumps that can meet the Q and

h requirements, one should choose the pump that operates at the maximum efficiency.

What is efficiency?

η =Output

Input

The maximum efficiency point is between the

maximum head condition (Q = 0) and the

maximum flow condition (h = 0).

Q

η = 0 when

Q = 0 and h = 0

Maximum

efficiencyη

ME 120: Pump performance page 10

Page 12: Pump Performance - Portland State University

Pump Efficiency (2)

Efficiency

η =Output

Input=

Desired outcome

Cost of obtaining the outcome

Each device has a conventional definition of Output and Input

For a pump:

Output = is the power delivered to the fluid

Input = is the power consumed by the motor

The units of Output and Input must be the same because efficiency is dimensionless.

Output and Input could be defined in terms of energy instead of power as long as the

units are consistent. Recall that power is the rate of energy transfer, i.e., energy transfer

per unit time.

NOTE: Computed values of efficiency will be meaningless if your units are inconsistent.

ME 120: Pump performance page 11

Page 13: Pump Performance - Portland State University

Pump Efficiency (3)

Output is rate at which usable energy is transferred to the fluid

Output = Rate at which fluid is elevated + flow of kinetic energy in output stream

= mgh + 12mv

2

wherem = mass flow rate (kg/s)

g = acceleration of gravity (m/s2)

h = pump head (m)

v = velocity of the water leaving the tube (m/s)

NOTE: Computed values of efficiency will be meaningless if your units are inconsistent.

ME 120: Pump performance page 12

Page 14: Pump Performance - Portland State University

Pump Efficiency (4)

Input is the electrical power supplied by the motor

Input = V I

whereV = voltage supplied to the motor (V)

I = current supplied to the motor (A)

Therefore

η =mgh+ 1

2mv2

V I

NOTE: Computed values of efficiency will be meaningless if your units are inconsistent.

ME 120: Pump performance page 13

Page 15: Pump Performance - Portland State University

Measuring Pump Power

The voltage across the pump motor is measured with a voltmeter in parallel with the

power leads.

The current through the pump motor is measured with an ammeter in series with the

positive lead to the pump.

42.2Powersupply

Pumpmotor

DCV DCA

11.6

++

Inlet

Outlet

ME 120: Pump performance page 14

Page 16: Pump Performance - Portland State University

Pump Performance Testing

Measure

h ∆m ∆t V I

Compute

m Q v η

Definitions:

h = pump head = distance the water stream is elevated

∆m = mass accumulated in time ∆t

∆t = time allowed for mass accumulation

V = voltage applied to pump motor

I = current drawn by pump motor

m = mass flow rate

Q = volumetric flow rate

v = fluid velocity in the tubing

η = pump efficiency

ME 120: Pump performance page 15

Page 17: Pump Performance - Portland State University

Summary of Pump Performance Testing

1. Follow the pump testing procedure to collect h, ∆m, ∆t, V and I at several (10 or

more) operating conditions, spread over the entire range of flow rates.

2. Compute m and Q at each data point.

m =∆m

∆t=⇒ Q =

m

ρ

3. From Q computed above, and the inner diameter of the tubing, compute v

Q = vA =⇒ v =Q

Awith A =

π

4d

2

4. Compute efficiency from

η =mgh+ 1

2mv2

V I

ME 120: Pump performance page 16

Page 18: Pump Performance - Portland State University

Summary of Pump Performance Testing (continued)

5. Create a plot of head versus flow rate

h

Q

Maximum head

at Q = 0

Maximum flow rate

at h = 0

ME 120: Pump performance page 17

Page 19: Pump Performance - Portland State University

Summary of Pump Performance Testing (continued)

6. Create a plot of efficiency versus flow rate

Q

η = 0 when

Q = 0 and h = 0

Maximum

efficiencyη

ME 120: Pump performance page 18