GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the...

6
THE ULTIMATE NATURAL ENERGY GEOTHERMAL HEAT Ikeda Technical Co., Ltd. Geo-MAX Geothermal Air-Conditioning System Geothermal heat utilization with voluminous air supply Domestic Patent Granted & International Patent Applied

Transcript of GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the...

Page 1: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

THE ULTIMATE NATURAL ENERGY

GEOTHERMAL HEAT!

Ikeda Technical Co., Ltd.

Geo-MAX

Geothermal Air-Conditioning System

Geothermal heat utilization with voluminous air supply

Domestic Patent Granted & International Patent Applied

Page 2: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

Large Volume Geothermal Air-Conditioning System

■ System Summary

1.The φ800mm or φ600㎜, polyethylene, double-layered pipes are jointed into

2~10(pcs)x5m length underground, and the air of 30~155㎥/min is blowing

through the pipes.

2.The heat-exchange pipes are buried at 2 meter deep at their bottom.

3.Given the circulating water is 15℃ and outside temperature is 35℃, the

outcoming temperature is approx. 25℃.

4.The system only requires space for installation.

5.Electricity consumption as running cost is 0.33~1.45KW/unit. *For fan &pumpIkeda Technical Co., Ltd.

Air Volume

30~155㎥/min

Air Inlet

Summer:Underground water

Winter:Solar heated water

Hot water from factory wastes

Air Passage

Geo-MAX

2

Geo-MAX is a brand-new AC system!

The pipes have spiral water passage and are able to

circulate cold underground water or hot water around air

duct, boosting heat-exchange efficiency under soil.

Domestic Patent Granted & International Patent Applied

Page 3: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

Typical Underground temp. gradient (year)

What is Geothermal Heat?

What is Geothermal Heat?

When you think of geothermal energy, you may imagine “hot” heats obtained from hot springs,

magmas, geothermal power-generations, and so on. The source of these hot heats is the earth’s internal

energy located far down from its surface.

The “Geothermal Heat” we describe here is the heat oriented from the solar energy and those energy

stored at the shallow underground from five to a hundred meters.

You can just imagine well water or limestone caves being chilly during hot summer and warm in cold

winter time.

This energy stored at the shallow level of the ground is said to be superior to other renewable energies

because it is not subject to short-term climate and weather changes.

TYPICAL UNDERGROUND TEMPERATURE (JAPAN)

Ikeda Technical Co., Ltd.

Solar Heat Energy

Easily influenced by

climate and weather.

Not stable.

Hydraulic Power Energy

Stably generated, but not

widely obtainable and

requires massive water

<<Geothermal Energy>>

Stably obtainable and

widely exist almost

everywhere in the world

and inexhaustible

Wave Energy

Restrictions in places

and stable supply is not

expected

Wind Energy

Restrictions in places and

stable supply is not

expected.

(over a day in winter)

Geo-MAX Burying Depth: 2mGL

2m

Winter

February

Summer

August

Temperature

Geothermal

Heat

Outside

Temp.

Chilly in

Summer

Warm in Winter

3

Solar energy Radiant heat

Earth thermal energy

Geothermal energy

Page 4: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

池田テクニカル株式会社

Project Name Target Season Size (approx.) # of unit Unit Length

Strawberry Picking Farm, Nagano Summer 810㎡ 1 Φ800-40m

Rose Farm, Shiga All year 5,200㎡ 1 Φ800-50m

Plant Factory, Chiba Summer 90㎡ 1 Φ600-15m

Control Machine Factory, Tokyo Summer 10,000㎡ 1 Φ800-30m

Major Machinery Company ,Yamaguchi All year 10,000㎡ 16 Φ800-10m

Tomato Farm, Aichi All year 36,000㎡32

8

Φ800-40m

Φ800-50m

Major Food Processing Company

Over Bridge Room for Visitor’s, IbarakiAll year 130㎡ 1 Φ800-15m

Orange Farm, Aichi Heating in Winter 1,000㎡ 1 Φ800-40m

Tomato Farm, AichiHeat

Prevention10,000㎡ 16 Φ800-40m

Major Construction Machinery Technical

Training Center, Fukushima

Heat

Prevention10,000㎡ 1 Φ800-30m

Nursing Home, Chiba All year 2,500㎡ 2 Φ800-30m

Mold Company, South KoreaHeat

Prevention10,000㎡ 24 Φ800-40m

Strawberry Picking Farm, Gifu Heating in Winter 2,600㎡ 2 Φ800-30m

PROJECT HISTORY

Page 5: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

Air Inlet Box

Air Outlet Duct

Air Outlet Duct

Air Volume:90~155㎥/min

Summer

Air Inlet

Flow

Gymnasiums・Arenas

Factories & Warehouses

Air Inlet

General houses

Air Volume:30㎥/min

Ikeda Technical Co., Ltd.

Air Inlet

Air Inlet

Box

Summer

Air Inlet

Flow

5

Air Volume:90~155㎥/min

Air Volume:90~155㎥/min

Geo-MAX Available to

Factories, Public Facilities, Arenas,

Gymnasiums, Warehouses, Apartments, Houses,

and Agriculture and Livestock Facilities

Page 6: GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the International Press Syndicate, and the president,

Geo-MAX Performance table

Other Services

Sales RepresentativeContact to IKEDA TECHNICAL CO.,LTD

Morimoto BL., 602,3-9-3, Uchikanda, Chiyoda-ku

Tokyo, 101-0047, Japan

TEL: +81-3-5244-4785 FAX +81-3-5244-4786

Mobile 090-2440-7120

URL http://ikedatechnical.hp.gogo.jp

Email [email protected] (ver.6)

Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the

International Press Syndicate, and the president, Mr. Ikeda(Right)

Geo-MAX at Milan Expo August 2015

KiP Pavilion Geo-MAX Exhibition

Geo-MAX, the unique technology in the world!

6

GMD600-10 GMD600-15 GMD600-20 GMD600-30 GMD800-15 GMD800-30 GMD800-40 GMD800-50

10m 15m 20m 30m 15m 30m 40m 50m

30㎥ 45㎥ 58㎥ 80㎥ 60㎥ 118㎥ 118㎥ 155㎥

1,800㎥ 2,700㎥ 3,480㎥ 4,800㎥ 3,600㎥ 7,080㎥ 7,080㎥ 9,300㎥

Outcoming Cooler (Outside35℃) 26.6℃ 26.6℃ 26.6℃ 26.6℃ 26.6℃ 26.6℃ 23.8℃ 24.2℃

Temperature* Heater (Outside 0℃) 6.3℃ 6.3℃ 6.3℃ 6.3℃ 6.3℃ 6.3℃ 8.4℃ 8.1℃

Cooler (Outside35℃) 5.5kw 8.2kw 10.6kw 14.6kw 10.9kw 21.5kw 28.7kw 36.5kw

Heater (Outside 0℃) 4.1kw 6.2kw 7.9kw 10.9kw 8.2kw 16.1kw 21.5kw 27.4kw

0.08kw 0.24kw 0.3kw 0.54kw 0.55kw 0.81kw 0.81kw 1.05kw

0.33kw 0.49kw 0.55kw 0.79kw 0.8kw 1.06kw 1.21kw 1.45kw

Housing Complex ○ ○ ◎

Factories ○ ○ ◎ ◎ ◎

Warehouses ○ ○ ◎ ◎ ◎

Agri-Facilities ○ ○ ◎ ◎ ◎

Greenhouses ○ ○ ◎ ◎ ◎

Plant Factories ○ ○ ◎ ◎ ◎

Installation SiteRecommendation

Air Volume(hour)

Power 100V/200V 200V

Total Electric ity

GA-600 (Φ600mm) GA-800 (Φ800mm)

0.25kw 0.25kw 0.4kw

Air Volume(min)

Duct Fan Electricity

Pump Electricity

Capacity*

Heat Exchange Pipe

Heat Exchange Length

*Given Water is at 15℃

Sales of Underground Tank (2 to 10 ton) and Panel Tanks (above 20 ton)

Sales and Installation of Mist Systems for Cooling, Deodorant and Dust Purpos.

Environment Consultation for Livestock and Agricultural Facilities. Sales of Rat Traps.

Design and Construction Instruction for Plant Factories and Agricultural Facilities