GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the...
Transcript of GEOTHERMAL HEATbestbiz.jp/ikedatechnical.hp.gogo.jp/pc/files/library/...Mr. Ramesh Jaura, the...
THE ULTIMATE NATURAL ENERGY
GEOTHERMAL HEAT!
Ikeda Technical Co., Ltd.
Geo-MAX
Geothermal Air-Conditioning System
Geothermal heat utilization with voluminous air supply
Domestic Patent Granted & International Patent Applied
Large Volume Geothermal Air-Conditioning System
■ System Summary
1.The φ800mm or φ600㎜, polyethylene, double-layered pipes are jointed into
2~10(pcs)x5m length underground, and the air of 30~155㎥/min is blowing
through the pipes.
2.The heat-exchange pipes are buried at 2 meter deep at their bottom.
3.Given the circulating water is 15℃ and outside temperature is 35℃, the
outcoming temperature is approx. 25℃.
4.The system only requires space for installation.
5.Electricity consumption as running cost is 0.33~1.45KW/unit. *For fan &pumpIkeda Technical Co., Ltd.
Air Volume
30~155㎥/min
Air Inlet
Summer:Underground water
Winter:Solar heated water
Hot water from factory wastes
Air Passage
Geo-MAX
2
Geo-MAX is a brand-new AC system!
The pipes have spiral water passage and are able to
circulate cold underground water or hot water around air
duct, boosting heat-exchange efficiency under soil.
Domestic Patent Granted & International Patent Applied
Typical Underground temp. gradient (year)
What is Geothermal Heat?
What is Geothermal Heat?
When you think of geothermal energy, you may imagine “hot” heats obtained from hot springs,
magmas, geothermal power-generations, and so on. The source of these hot heats is the earth’s internal
energy located far down from its surface.
The “Geothermal Heat” we describe here is the heat oriented from the solar energy and those energy
stored at the shallow underground from five to a hundred meters.
You can just imagine well water or limestone caves being chilly during hot summer and warm in cold
winter time.
This energy stored at the shallow level of the ground is said to be superior to other renewable energies
because it is not subject to short-term climate and weather changes.
TYPICAL UNDERGROUND TEMPERATURE (JAPAN)
Ikeda Technical Co., Ltd.
Solar Heat Energy
Easily influenced by
climate and weather.
Not stable.
Hydraulic Power Energy
Stably generated, but not
widely obtainable and
requires massive water
<<Geothermal Energy>>
Stably obtainable and
widely exist almost
everywhere in the world
and inexhaustible
Wave Energy
Restrictions in places
and stable supply is not
expected
Wind Energy
Restrictions in places and
stable supply is not
expected.
(over a day in winter)
Geo-MAX Burying Depth: 2mGL
2m
Winter
February
Summer
August
Temperature
Geothermal
Heat
Outside
Temp.
Chilly in
Summer
Warm in Winter
3
Solar energy Radiant heat
Earth thermal energy
Geothermal energy
池田テクニカル株式会社
Project Name Target Season Size (approx.) # of unit Unit Length
Strawberry Picking Farm, Nagano Summer 810㎡ 1 Φ800-40m
Rose Farm, Shiga All year 5,200㎡ 1 Φ800-50m
Plant Factory, Chiba Summer 90㎡ 1 Φ600-15m
Control Machine Factory, Tokyo Summer 10,000㎡ 1 Φ800-30m
Major Machinery Company ,Yamaguchi All year 10,000㎡ 16 Φ800-10m
Tomato Farm, Aichi All year 36,000㎡32
8
Φ800-40m
Φ800-50m
Major Food Processing Company
Over Bridge Room for Visitor’s, IbarakiAll year 130㎡ 1 Φ800-15m
Orange Farm, Aichi Heating in Winter 1,000㎡ 1 Φ800-40m
Tomato Farm, AichiHeat
Prevention10,000㎡ 16 Φ800-40m
Major Construction Machinery Technical
Training Center, Fukushima
Heat
Prevention10,000㎡ 1 Φ800-30m
Nursing Home, Chiba All year 2,500㎡ 2 Φ800-30m
Mold Company, South KoreaHeat
Prevention10,000㎡ 24 Φ800-40m
Strawberry Picking Farm, Gifu Heating in Winter 2,600㎡ 2 Φ800-30m
PROJECT HISTORY
Air Inlet Box
Air Outlet Duct
Air Outlet Duct
Air Volume:90~155㎥/min
Summer
Air Inlet
Flow
Gymnasiums・Arenas
Factories & Warehouses
Air Inlet
General houses
Air Volume:30㎥/min
Ikeda Technical Co., Ltd.
Air Inlet
Air Inlet
Box
Summer
Air Inlet
Flow
5
Air Volume:90~155㎥/min
Air Volume:90~155㎥/min
Geo-MAX Available to
Factories, Public Facilities, Arenas,
Gymnasiums, Warehouses, Apartments, Houses,
and Agriculture and Livestock Facilities
Geo-MAX Performance table
Other Services
Sales RepresentativeContact to IKEDA TECHNICAL CO.,LTD
Morimoto BL., 602,3-9-3, Uchikanda, Chiyoda-ku
Tokyo, 101-0047, Japan
TEL: +81-3-5244-4785 FAX +81-3-5244-4786
Mobile 090-2440-7120
URL http://ikedatechnical.hp.gogo.jp
Email [email protected] (ver.6)
Mr. Ramesh Jaura, the Director-General and Editor-in-Chief of the
International Press Syndicate, and the president, Mr. Ikeda(Right)
Geo-MAX at Milan Expo August 2015
KiP Pavilion Geo-MAX Exhibition
Geo-MAX, the unique technology in the world!
6
GMD600-10 GMD600-15 GMD600-20 GMD600-30 GMD800-15 GMD800-30 GMD800-40 GMD800-50
10m 15m 20m 30m 15m 30m 40m 50m
30㎥ 45㎥ 58㎥ 80㎥ 60㎥ 118㎥ 118㎥ 155㎥
1,800㎥ 2,700㎥ 3,480㎥ 4,800㎥ 3,600㎥ 7,080㎥ 7,080㎥ 9,300㎥
Outcoming Cooler (Outside35℃) 26.6℃ 26.6℃ 26.6℃ 26.6℃ 26.6℃ 26.6℃ 23.8℃ 24.2℃
Temperature* Heater (Outside 0℃) 6.3℃ 6.3℃ 6.3℃ 6.3℃ 6.3℃ 6.3℃ 8.4℃ 8.1℃
Cooler (Outside35℃) 5.5kw 8.2kw 10.6kw 14.6kw 10.9kw 21.5kw 28.7kw 36.5kw
Heater (Outside 0℃) 4.1kw 6.2kw 7.9kw 10.9kw 8.2kw 16.1kw 21.5kw 27.4kw
0.08kw 0.24kw 0.3kw 0.54kw 0.55kw 0.81kw 0.81kw 1.05kw
0.33kw 0.49kw 0.55kw 0.79kw 0.8kw 1.06kw 1.21kw 1.45kw
Housing Complex ○ ○ ◎
Factories ○ ○ ◎ ◎ ◎
Warehouses ○ ○ ◎ ◎ ◎
Agri-Facilities ○ ○ ◎ ◎ ◎
Greenhouses ○ ○ ◎ ◎ ◎
Plant Factories ○ ○ ◎ ◎ ◎
Installation SiteRecommendation
Air Volume(hour)
Power 100V/200V 200V
Total Electric ity
GA-600 (Φ600mm) GA-800 (Φ800mm)
0.25kw 0.25kw 0.4kw
Air Volume(min)
Duct Fan Electricity
Pump Electricity
Capacity*
Heat Exchange Pipe
Heat Exchange Length
*Given Water is at 15℃
Sales of Underground Tank (2 to 10 ton) and Panel Tanks (above 20 ton)
Sales and Installation of Mist Systems for Cooling, Deodorant and Dust Purpos.
Environment Consultation for Livestock and Agricultural Facilities. Sales of Rat Traps.
Design and Construction Instruction for Plant Factories and Agricultural Facilities