Fast Separations for Aggregates and Fragments Agilent AdvanceBio SEC 200 Å 1.9 μm columns

Transcript of Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio...

Page 1: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

Fast Separations for Aggregates and FragmentsAgilent AdvanceBio SEC 200 Å 1.9 μm columns

Page 2: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are
Page 3: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

3

Superior performance

– Unique hydrophilic bonding chemistry provides an inert surface minimizing secondary hydrophobic interaction with ADCs and mAbs.

– Optimized particles maximize efficiency and resolution.Greater durability

– Extended column lifetime and enhanced column productivity reduce costs.

– Fast analysis and uncompromised resolution improve productivity.

Assured reliability

– Every column is tested to ensure consistent performance.

– Batch-to-batch and column-to-column reproducibility gives you confidence in your analysis.

Optimized sub-2-micron particles give you the following advantages:

Size exclusion chromatography (SEC) is a reference method for the qualitative and quantitative analysis of protein aggregates, such as monoclonal antibodies (mAbs) and antibody drug conjugates (ADCs). Aggregates are critical quality attributes (CQAs) because they may alter biotherapeutic efficacy or immunogenicity.

AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC instruments. They are designed to improve resolution and deliver faster separation of mAb aggregates and lower molecular weight protein fragments.

Boost Your Productivity with Fast Aggregate and Fragment Analysis

1

2

3

Page 4: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

4

High resolution, high-efficiency separations, and an inert surfaceThe 1.9 µm silica particles modified by unique Agilent hydrophilic bonding chemistry ensure high resolution and separation efficiency. In addition, they minimize secondary interactions with mAbs, ADCs, and other proteins.

5.5

A: Agilent AdvanceBio SEC column 4.6 x 300 mm, 200 Å 1.9 µm

6 6.5 7 7.5 8 8.5 9 9.5 10

x102

1.2

10.8

0.60.4

0.2

0

5.5 6 6.5 7 7.5 8 8.5 9 9.5 10

x102

1.2

10.8

0.60.4

0.2

0

B: Competitor SEC column 1 4.6 x 300 mm, 200 Å 1.7 µm

5.5 6 6.5 7 7.5 8 8.5 9 9.5 10

x102

1.2

10.8

0.60.4

0.2

0

C: Competitor SEC column 2 4.6 x 300 mm, 250 Å 2.0 µm

Retention time [min]

Resp

onse

[mAU

]Re

spon

se [m

AU]

Resp

onse

[mAU

]

monomer

dimerLMW1

LMW2

Optimized sub-2 µm particles provide high resolution and efficient separation

AdvanceBio SEC columns demonstrate better resolution and separation efficiency, compared to competitive columns.

Superior Performance for mAb and ADC Characterization

Instrument: Agilent 1260 Infinity II Bio-inert LC system

Software: Agilent OpenLab CDS

Flow rate: 0.35 mL/min

Eluent: 50 mM sodium phosphate, 200 mM NaCl, pH 7.0

Temperature: 25 °C

Injection volume: 1 μL

Detection: UV, 220 nm

Peak Width 50% Resolution Back Pressure

(bar)monomer LMW1 LMW2 dimer/

monomermonomer/

LMW1

Agilent AdvanceBio SEC 1.9 µm

0.159 0.154 0.148 2.79 2.28 340

Competitor SEC column 1

0.172 0.166 0.160 2.46 2.09 354

Competitor SEC column 2

0.194 0.182 0.169 2.49 1.83 260

Size exclusion chromatograms of SigmaMAb mixed with LMW1 and LMW2 fragments.

5.6 6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2

6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2 9.6

5.8 6.2 6.6 7 7.4 7.8 8.2 8.6 9 9.4

5.6 6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2

6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2 9.6

5.8 6.2 6.6 7 7.4 7.8 8.2 8.6 9 9.4

5.6 6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2

6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.2 9.6

5.8 6.2 6.6 7 7.4 7.8 8.2 8.6 9 9.4

Page 5: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

5

Instrument: Agilent 1260 Infinity II Bio-inert LC system

Software: Agilent OpenLab CDS

Flow rate: 0.35 mL/min

Eluent: 50 mM sodium phosphate, 200 mM NaCl, pH 7.0

Temperature: 25 °C

Injection volume: 1 μL

Detection: UV, 220 nm

Peak Width 50% Resolution Back Pressure

(bar)monomer LMW1 LMW2 dimer/

monomermonomer/

LMW1

Agilent AdvanceBio SEC 1.9 µm

0.159 0.154 0.148 2.79 2.28 340

Competitor SEC column 1

0.172 0.166 0.160 2.46 2.09 354

Competitor SEC column 2

0.194 0.182 0.169 2.49 1.83 260

2 3 4 5 6 7 8 9 10 11 12 13

2 3 4 5 6 7 8 9 10 11 12 13

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

A: Agilent AdvanceBio SEC column 4.6 x 300 mm, 200 Å 1.9 µm

B: Competitor SEC column 1 4.6 x 300 mm, 200 Å 1.7 µm

C: Competitor SEC column 2 4.6 x 300 mm, 250 Å 2.0 µm

Retention time [min]

2 3 4 5 6 7 8 9 10 11 12 13

2 3 4 5 6 7 8 9 10 11 12 13

2 3 4 5 6 7 8 9 10 11 12 13

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

A: Agilent AdvanceBio SEC column 4.6 x 300 mm, 200 Å 1.9 µm

B: Competitor SEC column 1 4.6 x 300 mm, 200 Å 1.7 µm

C: Competitor SEC column 2 4.6 x 300 mm, 250 Å 2.0 µm

Retention time [min]

2 3 4 5 6 7 8 9 10 11 12 13

Inert surface contributes to good peak shape and prevents secondary interactions

AdvanceBio SEC 1.9 µm columns minimize secondary nonspecific interactions with sticky ADCs, and demonstrate better peak shape than the competition. Other manufacturers’ columns have undesirable secondary interactions, showing late sample elution and different separation forms.

Undesirable secondary interactions (peak is eluting later than expected and being separated into different forms)

Instrument: Agilent 1260 Infinity II Bio-inert LC system

Software: Agilent OpenLab CDS

Flow rate: 0.35 mL/min

Eluent: 50 mM sodium phosphate, 200 mM NaCl, pH 7.0

Temperature: 25 °C

Injection volume: 2 μL

Detection: UV, 220 nm

Size exclusion chromatograms of SigmaMAb ADC.

2 3 4 5 6 7 8 9 10 11 12 13

2 3 4 5 6 7 8 9 10 11 12 13

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

x102

2.5

2

1.5

1

0.5

0

Resp

onse

[mAU

]

A: Agilent AdvanceBio SEC column 4.6 x 300 mm, 200 Å 1.9 µm

B: Competitor SEC column 1 4.6 x 300 mm, 200 Å 1.7 µm

C: Competitor SEC column 2 4.6 x 300 mm, 250 Å 2.0 µm

Retention time [min]

2 3 4 5 6 7 8 9 10 11 12 13

Undesirable secondary interactions (peak is eluting later than expected)

9 9.1 9.2 9.38.9

9 9.1 9.2 9.38.9

9.6 9.7 9.89.59.4

9 9.1 9.2 9.38.9

9 9.1 9.2 9.38.9

9.6 9.7 9.89.59.4

9 9.1 9.2 9.38.9

9 9.1 9.2 9.38.9

9.6 9.7 9.89.59.4

Rs=2.55

Page 6: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

6

Extended lifetime helps your lab keep costs in checkWe engineered our 1.9 µm monodisperse silica particles for best-in-class mechanical strength and improved column lifetime. During development, columns were tested using a flow stop/start procedure, which is designed to mimic typical use in demanding laboratory environments.

Save Time and Reduce Costs

Competitor #11.7 µm

0

20

40

60

80

100

120

0 100 200 300 400 500

% E

ffici

ency

Performance < 80% initial value

Competitor #22.0 µm

AdvanceBio SEC1.9 µm

Uridine Plates

Injection number

Column: 4.6 x 300 mm

Mobile phase: 150 mM sodium phosphate, pH 7.0

Flow rate: 0.35 mL/min

Temperature: ambient

Detector: 220 nm

Sample: BioRad protein mix and uridine (stop flow every 50 injections)

AdvanceBio SEC 200 Å 1.9 µm columns showed less than 2% drop in plate number over 400 injections, confirming excellent mechanical stability

Page 7: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

7

Greater productivity through unsurpassed speed and resolutionFast analysis and extended column lifetime make AdvanceBio SEC 200 Å 1.9 μm columns an economically valuable addition to your laboratory. The excellent stability and high resolution at 0.7 mL/min will boost your productivity.

1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.5 5.8 6 6.2 6.4 6.6 6.8

x101

2

0

0.5

1

1.5

1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3

x101

2

0

0.5

1

1.5

Rs=1.81

Rs=1.58

0.3 mL/min164 bar

0.7 mL/min380 bar

6.8 min1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.5 5.8 6 6.2 6.4 6.6 6.8

x101

2

0

0.5

1

1.5

1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3

x101

2

0

0.5

1

1.5

Rs=1.81

Rs=1.58

0.3 mL/min164 bar

0.7 mL/min380 bar

3 min

Size exclusion chromatograms of SigmaMAb using an Agilent AdvanceBio SEC 200 Å 1.9 μm 4.6 x 150 mm column.

The fast analysis of the AdvanceBio SEC 1.9 µm column allows you to run more samples than ever before.

AdvanceBio SEC 1.9 µm column

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 12A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

samples/24 hr480

samples/24 hr280

1 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 12A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

AdvanceBio SEC 2.7 µm column

samples/24 hr72

1 2 3 4 5 6 7 8 9 10 11 12A

B

C

D

E

F

G

H

Old technology column

Analysis of SigmaMAbFast analysis can be achieved by increasing flow rates, without affecting resolution or stability.

AdvanceBio SEC 1.9 µm columns enable fast throughput analysis and retain the high resolution. A 150 mm column running at 0.7 mL/min demonstrates the ability to analyze 480 samples in 24 hours, while the column resolution at 0.3 mL/min is similar to 0.7 mL/min.

Page 8: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

8

Consistency of column performance enables confidence in your resultsDeveloped and manufactured by Agilent R&D scientists to exacting criteria, AdvanceBio SEC 200 Å 1.9 µm columns are tested during each process step. You can be confident in the quality, robustness, and performance—essential for fast and accurate separations.

Assured Reliability to Meet Your Quality Control Needs

2 4 6 8 10 12

0

250

500

750

1000

1250

1500

1750

2000

minRetention time (min)

Resp

onse

(mAU

)

Overlay of eight Bio-Rad protein standard chromatograms for 400 injections at an interval of 50 runs.

Achieve reproducible performance, injection to injection and run to run

Page 9: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

9

3 4 5 6 7 8 9 10

x103

1

0.8

0.6

0.4

0.2

0

Resp

onse

[mAU

]

3 4 5 6 7 8 9 10

x103

1

0.8

0.6

0.4

0.2

0

Resp

onse

[mAU

]

x103

1

0.8

0.6

0.4

0.2

0

Resp

onse

[mAU

]

3 4 5 6 7 8 9 10

monomer

dimer

Retention time (min)

Batch A

Batch B

Batch C

Resolution (dimer/monomer)

Retention Time(monomer)

Batch A 2.25 6.781

Batch B 2.37 7.086

Batch C 2.23 6.815

% RSD 3.3 2.4

Proven performance is ensured with a QC test of every batch

Every batch of Agilent AdvanceBio SEC 200 Å 1.9 µm media is tested using protein standards, as well as an IgG reference sample before release.

Instrument: Agilent 1260 Infinity II Bio-inert LC system

Software: Agilent OpenLab CDS

Column: 4.6 x 300 mm

Flow rate: 0.35 mL/min

Eluent: 150 mM sodium phosphate, pH 7.0

Temperature: 25 °C

Detection: UV, 220 nm

QC test of three production batches.

Page 10: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

10

Ordering Information

Description Part Number

AdvanceBio SEC 200 Å, 1.9 µm, 4.6 x 300 mm PL1580-5201

AdvanceBio SEC 200 Å, 1.9 µm, 4.6 x 150 mm PL1580-3201

AdvanceBio SEC 200 Å, 1.9 µm guard, 4.6 x 30 mm PL1580-1201

Download the AdvanceBio SEC 1.9 μm column user guide at www.agilent.com/chem/advancebiosec

Transform analytical data into meaningful resultsAgilent OpenLab software optimizes your bioanalysis LC workflows by reducing the time you spend on data processing, review, and reporting.

For more information, go to www.agilent.com/chem/openlab

Maximize efficiency at each step in your workflowAdvanceBio columns are part of the Agilent InfinityLab family—an optimized portfolio of LC instruments, MS detectors, columns, and supplies that work together in perfect harmony.

– The Agilent 1260 Infinity II Bio-inert LC system, together with AdvanceBio columns, gives you unmatched bioseparation power.

– Agilent InfinityLab Bio-inert supplies optimize performance and deliver the highest efficiency for your biomolecule analysis.

For more information, go to www.agilent.com/chem/infinitylab

Page 11: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

Agilent CrossLab: real insight, real outcomesCrossLab goes beyond instrumentation to bring you services, consumables, and lab-wide resource management. So your lab can improve efficiency, optimize operations, increase instrument uptime, develop user skill, and more.

For more information, go to www.agilent.com/crosslab

11

Page 12: Fast Separations for Aggregates and Fragments with AdvanceBio SEC … · 2019-09-18 · AdvanceBio SEC 200 Å 1.9 μm columns are suitable for UHPLC and HPLC . instruments. They are

Learn more: www.agilent.com/chem/advancebiosec

Find a local Agilent customer center in your country: www.agilent.com/chem/contactus

U.S. and Canada 1-800-227-9770 [email protected]

Europe [email protected]

Asia Pacific [email protected]

For Research Use Only. Not for use in diagnostic procedures.

This information is subject to change without notice.

© Agilent Technologies, Inc. 2019 Published in the USA, April 29, 2019 5994-0873EN