Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21...

594
Product catalog

Transcript of Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21...

Page 1: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Product catalogHoneywell Srl ACS Environmental ControlsVia Philips, 1220052 MonzaTelefono: +39 039 2165.1Email: [email protected]

Honeywell ΕΠΕACS Environmental ControlsΠολυτεχενείου, 2514122, Νέο ΗράκλειοΤηλ.: +30 210 2848049Φαξ: +30 210 2848055

UK3B-.................................

Subject to change without notice - All rights reserved www.honeywell.com

AC

S E

nviro

nmen

tal C

ontr

ols

Pro

duc

t ca

talo

g

Page 2: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room and Zone Control

Plant Control

Configurable controllers

Actuators

Valves linear

Valves rotary

Frequency inverters

Sensors

Thermostats

Miscellaneous

Thermostats, Timers

Zoning control

Radiator Valves and Thermostats

Balancing and Pipeline Valves

Page 3: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

0-2 http://products.ecc.emea.honeywell.com/europe

Page 4: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

15

16

17

18

19

20

21

22

24

23

25

26

27

28

Hydronic zoning

Boiler Room Valves

Metering

Pressure Reducing Valves, Pressure Regulators, residential/industrial

Filters, Strainers, Filter combinations, residential/industrial

Backflow Preventers, Non-return Valves, residential/industrial

Safety Valves/Groups, Thermostatic Mixing Valves, residential/industrial

Control Valves, residential/industrial

Thermostats

Pressure switches

Pressure transmitters

Solenoid Valves

Temperature sensors/transmitters

Hygrostats

Page 5: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

0-4 http://products.ecc.emea.honeywell.com/europe

Page 6: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

29

2

3

4

5

6

7

8

10

9

11

12

13

14

Flow monitors

Page 7: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

0-6 http://products.ecc.emea.honeywell.com/europe

Page 8: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-7

Numerics

075041061 4-110900247 18-190900248 18-19

0900249 18-190900250 18-190900251 18-190900252 18-190900253 18-19

0900255 18-190900256 18-190900257 18-190900258 18-190900259 18-19

0900260 18-190900261 18-190900356 20-250900357 20-250900358 20-25

0900359 20-250900360 20-250900361 20-250900577 16-180900761 16-18

0901353 18-190901354 18-190901355 18-190901356 18-190901357 18-19

0901358 18-190901359 18-190901444 20-240901445 20-240901446 20-24

0901447 20-240901448 20-240901515 18-4, 18-60901652 20-190901653 20-19

0901656 20-190901657 20-190901662 20-190901856 20-190903403 4-5

0903445 16-70903454 16-7, 16-80903733 20-8, 20-11, 20-12, 20-130903745 20-8, 20-11, 20-140903750 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-11, 22-12, 22-13, 22-14, 22-15

0903751 18-25, 22-2, 22-3, 22-5, 22-6, 22-7, 22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-15

0903752 18-25, 22-2, 22-3, 22-5, 22-6, 22-7, 22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-150903753 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-150903754 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13, 22-14, 22-15

0903755 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13, 22-14, 22-15

0903756 18-25, 22-2, 22-3, 22-5, 22-6, 22-7, 22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-15

0903757 18-25, 22-2, 22-3, 22-5, 22-6, 22-7, 22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-150903758 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13,

22-14, 22-150903759 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13, 22-14, 22-15

0903760 18-25, 22-2, 22-3, 22-5, 22-6, 22-7,

22-9, 22-10, 22-11, 22-12, 22-13, 22-14, 22-15

0903761 22-90903762 22-90903763 22-11

0903764 22-110903765 22-130903766 22-130903886 20-12, 20-130903889 20-12

0903890 18-60903919 18-70903920 18-70904031 20-190904032 20-19

0904033 20-190904034 20-190904052 20-210904053 20-210904054 20-21

0904055 20-210904056 20-210904057 20-210904058 20-210904059 20-21

0904060 20-210904061 20-210904062 20-210904063 20-210904064 20-21

0904065 20-210904066 20-210904067 20-210904068 20-210904069 20-21

0904070 20-210904071 20-210904072 20-210904117 20-80904118 20-8

0904119 20-80904120 18-200904121 18-202061400 20-252061500 20-25

2061600 20-252061700 20-252062000 20-252062400 20-252110200 19-27, 20-12, 20-13, 20-23, 20-24,

21-72110400 19-272110500 19-272164400 20-242164500 20-24

2164600 20-242164700 20-242166200 16-7, 20-24, 21-72192900 16-19, 20-112193100 20-11

2193200 20-112193300 20-112193400 20-112193500 20-112421100 16-12, 16-19

40007035-005 15-343191679-001 4-943191679-002 4-943191679-007 4-943191679-008 4-9

43191679-011 4-743191679-012 4-743191680-002 4-943191680-005 4-743191680-205 4-8

43193862-001 3-6, 3-7, 3-8, 3-9, 3-1043196000-001 4-7, 4-8, 4-943196000-002 4-7, 4-8, 4-943196000-038 4-95531500 20-25

5534900 20-255535100 20-255535300 20-255535500 20-255535700 20-25

Page 9: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-8 http://products.ecc.emea.honeywell.com/europe

5622100 19-195708000 18-195708100 18-195708200 18-195708300 18-19

5708400 18-195708500 18-195708600 18-1966-300 22-1070-550 22-7

70-610 22-776-600 22-6

AA152-1/2AA 21-3, 21-7, 21-9, 21-11, 21-13A152-1/2AB 21-3, 21-7, 21-9, 21-11, 21-13A152-1/2AC 21-3, 21-7, 21-9, 21-11, 21-13

A152-1/2BB 21-3A152-1/2BC 21-3A152-1AA 21-3, 21-11, 21-13A152-1AB 21-3, 21-11, 21-13A152-1AC 21-3, 21-11, 21-13

A152-3/4AA 21-3, 21-7, 21-9, 21-11, 21-13A152-3/4AB 21-3, 21-7, 21-9, 21-11, 21-13A152-3/4AC 21-3, 21-7, 21-9, 21-11, 21-13A152-3/4BB 21-3A152-3/4BC 21-3

A160-11/4AA 21-3A160-11/4AB 21-3A160-11/4AC 21-3A162-BA 21-14, 21-15A162-BC 21-14, 21-15

AA76-1/2A 19-4, 19-7, 19-9, 19-15, 19-26, 19-31, 19-35, 19-39

AB10 26-2AB13 26-2AB20 26-2

AB25 26-2AB32 26-2AB40 26-2AB50 26-2AC-15FS 5-4, 5-8, 5-26, 5-30, 5-36, 5-38

AC-15FT 5-4, 5-8, 5-26, 5-30, 5-36, 5-38AC-15TF 5-42AC-20FS 5-4, 5-8, 5-26, 5-30, 5-36, 5-38AC-20FT 5-4, 5-8, 5-26, 5-30, 5-36, 5-38AC-20TF 5-42

AC-25T 5-10, 5-40AC-25TF 5-10, 5-40, 5-42AC-32T 5-10, 5-40AC-32TF 5-10, 5-40, 5-42AC-40T 5-10, 5-40

AC-40TF 5-10, 5-40, 5-42AC-50TF 5-42ACN-15C 5-2, 5-6, 5-24, 5-28, 5-32, 5-34ACN-15S 5-2, 5-6, 5-24, 5-28, 5-32, 5-34ACN-15T 5-2, 5-6, 5-24, 5-28, 5-32, 5-34

ACN-20C 5-2, 5-6, 5-24, 5-28, 5-32, 5-34ACN-20S 5-2, 5-6, 5-24, 5-28, 5-32, 5-34ACN-20T 5-2, 5-6, 5-24, 5-28, 5-32, 5-34ACN-25T 5-2, 5-24, 5-28ACS-15T 5-12

ACS-15W 5-12ACS-20T 5-12ACS-20W 5-12ACS-25T 5-4, 5-12, 5-26, 5-30ACS-25W 5-12

ACS-32T 5-12ACS-32W 5-12AD300 16-11AD300-1/2 16-19AE295STN-11/2A 20-14

AF11DS-1/2A 19-4, 19-26AF11DS-1/2B 19-3, 19-25AF11DS-1/2C 19-3, 19-25AF11DS-1/2D 19-3, 19-25AF11DS-1/2E 19-3, 19-25

AF11DS-1/2F 19-3, 19-25AF11DS-1A 19-4, 19-7, 19-9, 19-26, 19-31,

19-35AF11DS-1B 19-3, 19-25AF11DS-1C 19-3, 19-25

AF11DS-1D 19-3, 19-25AF11DS-1E 19-3, 19-25AF11DS-1F 19-3, 19-25AF11S-1/2A 19-4, 19-26AF11S-1/2B 19-3, 19-25

AF11S-1/2C 19-3, 19-25AF11S-1/2D 19-3, 19-25AF11S-1/2E 19-3, 19-25AF11S-1/2F 19-3, 19-25AF11S-11/2A 19-4, 19-15, 19-26, 19-39

AF11S-11/2B 19-3, 19-15, 19-25, 19-39AF11S-11/2C 19-3, 19-15, 19-25, 19-39AF11S-11/2D 19-3, 19-15, 19-25, 19-39AF11S-11/2E 19-3, 19-15, 19-25, 19-39AF11S-11/2F 19-3, 19-15, 19-25, 19-39

AF11S-1A 19-4, 19-15, 19-26, 19-39AF11S-1B 19-3, 19-15, 19-25, 19-39AF11S-1C 19-3, 19-15, 19-25, 19-39AF11S-1D 19-3, 19-15, 19-25, 19-39AF11S-1E 19-3, 19-15, 19-25, 19-39

AF11S-1F 19-3, 19-15, 19-25, 19-39AF20 3-3, 3-6, 8-8AF74-1A 19-5, 19-8, 19-27, 19-29, 19-33AF74-1C 19-5, 19-8, 19-27, 19-29, 19-33AF74-1D 19-5, 19-8, 19-27, 19-29, 19-33

AF76S-065A 19-19AF76S-065C 19-19AF76S-065D 19-19AF76S-080A 19-19AF76S-080C 19-19

AF76S-080D 19-19AF76S-100A 19-19AF76S-100C 19-19AF76S-100D 19-19AGF1 8-14

AK15-15 5-12AK20-15 5-12AK20-25 5-12AK25-25 5-12ALF21 27-3

ALF31 27-3AQS71-KAM-T 8-37AS06-1/2A 19-11, 19-36AS06-1A 19-11, 19-36AS100V 13-16

AS100VM 13-16AS2 4-12ASL453 8-38, 29-3ASL453/24 8-38, 29-3AST1 23-3

ASW454 8-39, 29-4ASW454/24 8-39, 29-4AT10 26-4AT13 26-4AT20 26-4

AT25 26-4AT32 26-4AT40 26-4AT50 26-4ATC928G1000 12-2

ATC928G1026 12-2ATF100 12-2ATF200 12-2ATF300 12-2ATF400 12-2

ATP921G1034 12-2ATP921G1052 12-2ATP921G1080 12-2ATP921H1004 12-2ATP923G1064 12-2

ATP924G1002 12-2ATP924G1010 12-2ATP924G1018 12-2ATP925G1058 12-2ATP926G1050 12-2

AV102MS2 26-4AV103MS2 26-4AV131MS2 26-4AV201MS2 26-4AV251MS2 26-4

Page 10: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-9

AV252MS2 26-4AV401MS2 26-4AV402MS2 26-4AVSOLAR-1/2 16-17AVSOLAR-3/8 16-17

BBA195-3/8A 20-6BA195-3/8E 20-6BA295-1/2A 20-7

BA295-1/2E 20-7BA295-11/2A 20-7BA295-11/2E 20-7BA295-11/4B 20-7BA295-11/4E 20-7

BA295-1B 20-7BA295-1E 20-7BA295-2A 20-7BA295-2E 20-7BA295-3/4A 20-7

BA295-3/4E 20-7BA295C-1/2A 20-10BA295C-11/2A 20-10BA295C-11/4B 20-10BA295C-1B 20-10

BA295C-2A 20-10BA295C-3/4A 20-10BA295I-1/2A 20-9BA295I-11/2A 20-9BA295I-11/4A 20-9

BA295I-1A 20-9BA295I-2A 20-9BA295I-3/4A 20-9BA295STN-11/2A 20-14BA295STN-3/4A 20-12

BA295STN-3/4AC12 20-12BA295STN-3/4WH 20-13BA298-100FA 20-18BA298-150FA 20-18BA298-65FA 20-18

BA298-80FA 20-18BA298I-100FA 20-19BA298I-150FA 20-19BA298I-65FA 20-19BA298I-80FA 20-19

BA300-100A 20-20BA300-150A 20-20BA300-200A 20-20BA300-65A 20-20BA300-80A 20-20

BDR91A1000 11-9, 12-3BDR91T1004 11-9, 11-19BS295STN-11/2A 20-14BV300-100A 22-2BV300-150A 22-2

BV300-200A 22-2BV300-250A 22-2BV300-300A 22-2BV300-350A 22-2BV300-400A 22-2

BV300-450A 22-2BV300-50A 22-2BV300-65A 22-2BV300-80A 22-2

CC7068A1007 8-10C7068A1007-5M 8-10C7068A1030 8-10

C7085A1006 8-14C7085A1014 8-9C7110A1010 8-36C7110C1001 8-36C7110D1009 8-37

CA295-1/2A 20-5CA295-1/2ZA 20-5CA295-3/4A 20-5CA295-3/4ZA 20-5CFT1 8-32, 8-33, 24-6, 25-3

CLAR2DRV-A2A 2-16CLAR2DRV-CBUS 2-16CLAR2DRV-LONR 2-16CLAR2SL10 2-16CLAR2SL99 2-16

CLAR2UL99 2-16CLAXARENA 2-20CLAXARENAAPC 2-20CLAXARENAAXI 2-21CLAXARENAAXI4 2-21

CLAXARENADED 2-21CLAXARENADED4 2-21CLAXARENALINUX 2-20CLAXARENAMIL 2-21CLAXARENAMIL4 2-21

CLAXARENARUP 2-21CLAXARENARUP2 2-21CLAXARENASBS01 2-20CLAXARENASBS10 2-20CLAXARENASBSU1 2-21

CLAXARENASBSUP 2-21CLAXARENASKYPE 2-21CLAXARENASMS 2-21CLAXARENAW64UP 2-21CLAXARENAWOS64 2-20

CLAXCOACH 2-19CLAXCOACHSI 2-19CLAXDBCSV 2-21CLAXDBDB2 2-21CLAXDBMYSQL 2-21

CLAXDBORCL 2-21CLAXDBSQL 2-21CLAXDBTBL 2-21CLAXDRACX 2-19CLAXDRAXI 2-19

CLAXDRBAC500 2-21CLAXDRBACAWS 2-21CLAXDRBACEXP 2-21CLAXDRBACOWS 2-21CLAXDRBPORT 2-19

CLAXDRDED 2-19CLAXDREIB 2-21CLAXDREIB500 2-21CLAXDREVO 2-19CLAXDRFIDELIO 2-19, 2-21

CLAXDRFLX 2-19CLAXDRGCIR 2-19CLAXDRGL1 2-19CLAXDRGLX 2-19CLAXDRHLV 2-19

CLAXDRHRSM 2-19CLAXDRHTR 2-19CLAXDRINF 2-19CLAXDRLONIP 2-21CLAXDRLONIP500 2-21

CLAXDRMBSIP 2-21CLAXDRMBSIP500 2-21CLAXDRMIL 2-19CLAXDRMTCP 2-21CLAXDRMTCP500 2-21

CLAXDROBX 2-21CLAXDROBX500 2-21CLAXDROPC 2-21CLAXDROPC500 2-21CLAXDROPE 2-21

CLAXDROPE500 2-21CLAXDRPRO 2-19CLAXDRRSL 2-19CLAXDRSMS 2-19CLAXDRSNMP 2-21

CLAXDRSNMP500 2-21CLAXDRTBL 2-19CLAXHAWK16UP36 2-18CLAXHAWK216M 2-18CLAXHAWK216MGP 2-18

CLAXHAWK220 2-17CLAXHAWK22UP23 2-18CLAXHAWK230 2-17CLAXHAWK236M 2-18CLAXHAWK236MGP 2-18

CLAXHAWK23UP24 2-18CLAXHAWK240 2-17CLAXHAWK246M 2-18CLAXHAWK246MGP 2-18CLAXHAWK24UP25 2-18

Page 11: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-10 http://products.ecc.emea.honeywell.com/europe

CLAXHAWK250 2-17CLAXHAWK256M 2-18CLAXHAWK256MGP 2-18CLAXHAWK36UP46 2-18CLAXHAWK46UP56 2-18

CLAXHAWK630 2-17CLAXHAWK63UP64 2-18CLAXHAWK640 2-17CLAXHAWK64UP65 2-18CLAXHAWK650 2-17

CLAXHAWK65UP66 2-18CLAXHAWK660 2-17CLAXHAWKIF232 2-18CLAXHAWKIF485 2-18CLAXHAWKIFLON 2-18

CLAXHAWKIO16 2-18CLAXHAWKIO34 2-18CLAXHAWKRUP 2-18CLAXHAWKRUP2 2-18CLAXIFGPRS 2-19

CLAXIFGPRSACC 2-19CLAXNPBPWR 2-19CLAXNPBPWR230 2-19CLAXWPMEU 2-19CLAXWPMUK 2-19

CLCH2EL1 2-7, 2-8CLCH2EL2 2-7, 2-8CLCH2EL3 2-7, 2-8CLCH2EL4 2-7, 2-8CLCM1C155 8-2

CLCM1H112 8-3CLCM1T11N 8-3CLCM2T11N 8-3CLCM3T111 8-3CLCM4C155 8-2

CLCM4T111 8-3CLCM5T111 8-3CLCM6H212 8-4CLCM6T111 8-3CLCM6T21N 8-4

CLCMNA172B 8-2CLCMTR71 1-11CLCMTR71-H 1-11CLCMTR75 1-11CLCMTR75-H 1-11

CLEA2000B01 2-3CLEA2000B21 2-3CLEA2014B01 2-3CLEA2014B21 2-3CLEA2026B01 2-3

CLEA2026B21 2-3CLEMAN25 2-22CLEMAN50 2-22CLEMAN75 2-22CLFA100LB0C 2-5

CLFA300LB0C 2-5CLFA50LB0C 2-5CLFA600LB0C 2-5CLIF-CBUS1-PC 2-12, 2-16CLIF-CBUS2-PC 2-12, 2-16

CLIOL821A 2-3, 2-12CLIOL822A 2-3, 2-12CLIOL823A 2-3, 2-12CLIOL824A 2-3, 2-12CLIOLR822A 2-3, 2-12

CLIOLR824A 2-3, 2-12CLIOP821A 2-3, 2-9CLIOP822A 2-3, 2-9CLIOP823A 2-3, 2-9CLIOP824A 2-3, 2-9

CLIOP830A 2-4, 2-10CLIOP831A 2-4, 2-10CLIOPR822A 2-3, 2-9CLIOPR824A 2-3, 2-9CLIOPR825A 2-3, 2-9

CLLIONLC01 2-9CLLYUB1012S 1-11CLLYUB4024S 1-11CLLYUB6438S 1-11CLLYUL1012S 1-11

CLLYUL4024S 1-11CLLYUL6438S 1-11CLLYVB0000AS 1-11CLLYVB4022AS 1-11CLLYVB4024NS 1-11

CLLYVB6436AS 1-11CLLYVB6438NS 1-11CLLYVL0000AS 1-11CLLYVL4022AS 1-11CLLYVL4024NS 1-11

CLLYVL6436AS 1-11CLLYVL6438NS 1-11CLMMI00N22 2-7, 2-8, 2-10, 2-14CLMMI00N31 2-4, 2-7, 2-8, 2-10, 2-15CLMMI00N31-ACC 2-15

CLMMI8-1 2-14CLPA13LC02 2-6CLPA13LC12 2-6CLPA13LM02 2-6CLPA13LM12 2-6

CLPA21LC02 2-7CLPA21LC12 2-7CLPA21LC22 2-7CLPA21LM02 2-7CLPA21LM12 2-7

CLPD01240W 2-7CLPDU02240W 2-7CLSE1L230 1-10CLSE1L24 1-10CLSE2L230 1-10

CLSE3L230 1-10CLTG00MMIN01 2-8CLTG38EXPN01 2-8CLTG38L01 2-8CLTG38L11 2-8

CM31I 11-7CM37I 11-6CM67RFMV 12-5CM901I 11-4CM907I 11-4

CMS921B1018 11-3CMS921B1026 11-3CMS921B1042 11-3CMS927B1015 11-3, 12-5CMS927B1023 11-3

CMS927B1031 11-3CMS927B1049 11-3CMS927B1056 11-3CMS927B1064 11-3CMS927B1072 11-3

CMT701A1006 11-5CMT701A1014 11-5CMT702A1004 11-5CMT702A1012 11-5CMT707A1003 11-5

CMT707A1011 11-5CMT707A1029 11-5CMT707A1037 11-5CMT901A1010 11-4CMT901A1028 11-4

CMT901A1036 11-4CMT901A1044 11-4CMT907A1017 11-4CMT907A1025 11-4CMT907A1033 11-4

CMT907A1041 11-4CMT907A1066 11-4CMT907A1074 11-4CMT907A1082 11-4CMT921A1018 11-2

CMT921A1026 11-2CMT921A1042 11-2CMT927A1015 11-2CMT927A1023 11-2CMT927A1031 11-2

CMT927A1049 11-2CMT927A1056 11-2CMT927A1064 11-2CMT927A1072 11-2COMP230-1P1-20 7-3

COMP230-1P5-20 7-3COMP230-2P2-20 7-3COMP230-P37-20 7-3COMP230-P75-20 7-3COMP400-1P1-20 7-3

Page 12: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-11

COMP400-1P5-20 7-3COMP400-2P2-20 7-3COMP400-3P0-20 7-3COMP400-4P0-20 7-3COMP400-5P5-20 7-3

COMP400-P55-20 7-3COMP400-P75-20 7-3COMP-IP21-KIT1 7-12COMP-IP21-KIT2 7-12COMP-IP21-KIT3 7-12

COMP-LOADER 7-11COMP-LOADER-NC 7-11COMP-NEMA1-KIT1 7-12COMP-NEMA1-KIT2 7-12COMP-NEMA1-KIT3 7-12

CPDU01110W 2-7CRT12 10-5CRT2 10-5CRT6 10-5CRT6-12 10-5

CRT6-6 10-5CS92A1007 11-19CX-FR 22-14CX-PR 18-25, 22-5, 22-15CX-PS 22-3, 22-12, 22-15

DD03-1/2C 18-2D03-3/4C 18-2D03-3/4ZA 18-2

D04FS-1/2A 18-3D04FS-3/4A 18-3D04FS-3/8A 18-3D04FSA-1/2 18-3D05F-1/2A 18-4

D05F-1/2E 18-4D05F-1A 18-4D05F-1E 18-4D05F-3/4A 18-4D05F-3/4E 18-4

D05FA-1/2B 18-4, 18-6D05FA-1/2T 18-7D05FA-11/4B 18-6D05FA-11/4T 18-7D05FS-1/2A 18-5

D05FS-1/2E 18-5D05FS-11/2A 18-5D05FS-11/2E 18-5D05FS-11/4A 18-5D05FS-11/4E 18-5

D05FS-1A 18-5D05FS-1E 18-5D05FS-2A 18-5D05FS-2E 18-5D05FS-3/4A 18-5

D05FS-3/4E 18-5D05FT-1/2A 18-7D05FT-1/2E 18-7D05FT-11/2A 18-7D05FT-11/2E 18-7

D05FT-11/4A 18-7D05FT-11/4E 18-7D05FT-1A 18-7D05FT-1E 18-7D05FT-2A 18-7

D05FT-2E 18-7D05FT-3/4A 18-7D05FT-3/4E 18-7D06F-1/2A 18-8D06F-1/2B 18-8, 20-8, 20-9, 20-10

D06F-1/2E 18-9D06F-11/2A 18-8D06F-11/2B 18-8, 20-8, 20-9, 20-10D06F-11/2E 18-9D06F-11/4A 18-8

D06F-11/4B 18-8, 20-8, 20-9, 20-10D06F-11/4E 18-9D06F-1A 18-8D06F-1B 18-8, 20-8, 20-9, 20-10D06F-1E 18-9

D06F-2A 18-8D06F-2B 18-8, 20-8, 20-9, 20-10D06F-2E 18-9D06F-3/4A 18-8D06F-3/4B 18-8, 20-8, 20-9, 20-10

D06F-3/4E 18-9D06FA-1/2 16-7, 16-10, 16-12, 18-9, 18-13,

19-26, 19-36, 19-39, 21-9, 21-13D06FA-11/2 18-9, 18-13, 19-26, 19-39D06FA-1A 18-13, 19-26, 19-31, 19-35, 21-13

D06FA-1B 18-9, 19-27, 19-29, 19-33, 19-36, 19-39

D06FB-1A 19-7, 19-9D06FH-1/2B 18-12D06FH-11/2B 18-12

D06FH-11/4B 18-12D06FH-1B 18-12D06FH-2B 18-12D06FH-3/4B 18-12D06FI-1 18-11

D06FI-1/2 18-11D06FI-1/2A 18-10D06FI-1/2B 18-10D06FI-1/2E 18-11D06FI-11/2 18-11

D06FI-11/2A 18-10D06FI-11/2B 18-10D06FI-11/2E 18-11D06FI-11/4A 18-10D06FI-11/4B 18-10

D06FI-11/4E 18-11D06FI-1A 18-10D06FI-1B 18-10D06FI-1E 18-11D06FI-2A 18-10

D06FI-2B 18-10D06FI-2E 18-11D06FI-3/4A 18-10D06FI-3/4B 18-10D06FI-3/4E 18-11

D06FN-1/2B 18-14D06FN-11/2B 18-14D06FN-11/4B 18-14D06FN-1B 18-14D06FN-2B 18-14

D06FN-3/4B 18-14D06FNA-1 18-15D06FNA-1/2 18-15D06FNA-11/2 18-15D06FR 19-5

D06FR-1A 19-8D150-1/2 21-7D15NP-100A 18-18D15NP-125A 18-18D15NP-150A 18-18

D15NP-50A 18-18D15NP-65A 18-18D15NP-80A 18-18D15P-100A 19-19D15P-125A 18-17

D15P-150A 18-17D15P-200A 18-17D15P-50A 18-17D15P-65A 19-19D15P-80A 19-19

D15S-100A 18-20D15S-65A 18-20D15S-80A 18-20D160S-3/4 21-7D16-15A 18-21

D16-20A 18-21D162-1/2A 21-14, 21-15D16-25A 18-21D16-32A 18-21D16-40A 18-21

D16A-15 18-21D16A-25 18-21D16A-40 18-21D16N-15A 18-22D16N-20A 18-22

D16N-25A 18-22D16N-32A 18-22D16N-40A 18-22D16NA-15 18-22D16NA-25 18-22

Page 13: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-12 http://products.ecc.emea.honeywell.com/europe

D16NA-40 18-22D17P-100B 18-23D17P-150B 18-23D17P-200B 18-23D17P-50B 18-23

D17P-65B 18-23D17P-80B 18-23D22-1/2A 18-16D22-1/4A 18-16D22-11/2A 18-16

D22-11/4A 18-16D22-1A 18-16D22-2A 18-16D22-3/4A 18-16D22-3/8A 18-16

DA74C-11/4A 19-5, 19-8, 19-9, 19-29, 19-33, 19-35

DA74C-1A 19-5, 19-8, 19-9, 19-29, 19-33, 19-35

DA74C-3/4A 19-5, 19-8, 19-9, 19-29, 19-33,

19-35DA74CS-1/2A 19-5, 19-8, 19-29, 19-33DCM025 8-21, 24-8DCM06 8-21, 24-8DCM1 8-21, 24-8

DCM10 8-21, 24-8DCM1000 24-9DCM16 8-21, 24-8DCM25 8-21, 24-8DCM3 8-21, 24-8

DCM40 8-21, 24-8DCM4016 24-9DCM4025 24-9DCM506 24-9DCM6 8-21, 24-8

DCM625 8-21, 24-8DCM63 8-21, 24-8DCMV025 8-22, 24-9DCMV06 8-22, 24-9DCMV1 8-22, 24-9

DCMV10 8-22, 24-9DCMV16 8-22, 24-9DCMV25 8-22, 24-9DCMV3 8-22, 24-9DCMV40 8-22, 24-9

DCMV6 8-22, 24-9DCMV63 8-22, 24-9DDCM014 8-23, 24-12DDCM1 8-23, 24-12DDCM16 8-23, 24-12

DDCM1602 8-23, 24-12DDCM252 8-23, 24-12DDCM4 8-23, 24-12DDCM6 8-23, 24-12DDCM6002 8-23, 24-12

DDCM662 8-23, 24-12DDS76-1 19-3, 19-19DDS76-1/2 19-3DDS76-11/2 19-3DGM06A 24-15

DGM1A 24-15DGM306A 24-15DGM310A 24-15DGM325A 24-15DGM506 24-15

DGM516 24-15DGM525 24-15DH300-100A 22-3DH300-150A 22-3DH300-200A 22-3

DH300-250A 22-3DH300-300A 22-3DH300-350A 22-3DH300-400A 22-3DH300-450A 22-3

DH300-50A 22-3DH300-65A 22-3DH300-80A 22-3DKF20 8-8DMW 24-32, 25-6

DNM025 8-21, 24-8DNS025-201 24-11DNS025-203 24-11DNS06-201 24-11DNS06-203 24-11

DNS10-201 24-11DNS10-203 24-11DNS1-201 24-11DNS1-203 24-11DNS16-201 24-11

DNS16-203 24-11DNS3-201 24-11DNS3-203 24-11DNS6-201 24-11DNS6-203 24-11

DPS1000 8-23DPS1000F 24-24DPS200 8-23DPS200F 24-24DPS2500 8-23

DPS2500F 24-24DPS400 8-23DPS400F 24-24DPS500 8-23DPS500F 24-24

DPSK 8-35, 25-5DPSL 8-23, 8-35, 24-24, 25-5DPTM100 8-34, 25-4DPTM1000 8-34, 25-4DPTM1000D 8-34, 25-5

DPTM1002 8-34, 25-5DPTM100D 8-34, 25-5DPTM102 8-34, 25-5DPTM110 8-34, 25-4DPTM1100 8-34, 25-4

DPTM1100D 8-34, 25-5DPTM1102 8-34, 25-5DPTM110D 8-34, 25-5DPTM112 8-34, 25-5DPTM250 8-34, 25-4

DPTM250D 8-34, 25-5DPTM252 8-34, 25-5DPTM50 8-34, 25-4DPTM500 8-34, 25-4DPTM5000 8-34, 25-4

DPTM5000D 8-34, 25-5DPTM5002 8-34, 25-5DPTM500D 8-34, 25-5DPTM502 8-34, 25-5DPTM50D 8-34, 25-5

DPTM52 8-34, 25-5DPTM550 8-34, 25-4DPTM550D 8-34, 25-5DPTM552 8-34, 25-5DR100GFLA 6-4

DR125GFLA 6-4DR150GFLA 6-4DR15-2GMLA 6-4DR15GMLA 6-4DR200GFLA 6-4

DR200GFLA1 6-4DR20GFLA 6-4DR20GMLA 6-4DR25GFLA 6-4DR25GMLA 6-4

DR300-100A 18-24, 22-4DR300-100B 18-25, 22-5DR300-150A 18-24, 22-4DR300-150B 18-25, 22-5DR300-200A 18-24, 22-4

DR300-200B 18-25, 22-5DR300-250A 18-24, 22-4DR300-250B 18-25, 22-5DR300-300A 18-24, 22-4DR300-300B 18-25, 22-5

DR300-350A 18-24, 22-4DR300-350B 18-25, 22-5DR300-400A 18-24, 22-4DR300-400B 18-25, 22-5DR300-450A 18-24, 22-4

DR300-450B 18-25, 22-5DR300-50A 18-24, 22-4DR300-50B 18-25, 22-5DR300-65A 18-24, 22-4DR300-65B 18-25, 22-5

Page 14: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-13

DR300-80A 18-24, 22-4DR300-80B 18-25, 22-5DR32GFLA 6-4DR32GMLA 6-4DR40GFLA 6-4

DR40GMLA 6-4DR50GFLA 6-4DR65GFLA 6-4DR80GFLA 6-4DRA02B 7-12

DRA-02L 7-12DRA-04B 7-12DRA-04L 7-12DRF20-S 8-5DRR25-10 6-12

DRR25-16 6-12DRR25-2.5 6-12DRR25-4.0 6-12DRR25-6.3 6-12DRU25-10 6-11

DRU25-16 6-11DRU25-2.5 6-11DRU25-4.0 6-11DRU25-6.3 6-11DRU32-10 6-11

DRU32-16 6-11DRU32-25 6-11DS05-1 18-6, 18-7DS05-1/2 18-6, 18-7DS05-11/2 18-6, 18-7

DS05-11/4 18-6, 18-7DS05-2 18-6, 18-7DS05-3/4 18-6, 18-7DS295STN-11/2 20-14DT90A1008 11-8

DT90E1012 11-8DT92A1004 11-9DT92E1000 11-9DTS92A1011 11-9, 12-3DTS92E1020 11-9, 11-19, 12-3

DU144A1001 16-13DU144A1002 16-13DU144A1003 16-13DU145-3/4A 16-14DU145-3/4E 16-14

DU146-11/4A 16-15DU146-3/4A 16-15DU146AH-A 16-15DU146M-11/4A 16-16DU146M-3/4A 16-16

DWAM06 24-17DWAM1 24-17DWAM16 24-17DWAM32 24-17DWAM6 24-17

DWAM625 24-17DWAMV1 24-17DWAMV16 24-17DWAMV32 24-17DWAMV6 24-17

DWR06 8-25, 24-19DWR06-203 8-25, 24-19DWR06-205 24-20DWR06-206 8-26, 24-21DWR1 8-25, 24-19

DWR1-203 8-25, 24-19DWR1-205 24-20DWR1-206 8-26, 24-21DWR16 8-25, 24-19DWR16-203 8-25, 24-19

DWR16-205 24-20DWR16-206 8-26, 24-21DWR25 8-25, 24-19DWR25-203 8-25, 24-19DWR25-205 24-20

DWR25-206 8-26, 24-21DWR3 8-25, 24-19DWR3-203 8-25, 24-19DWR3-205 24-20DWR3-206 8-26, 24-21

DWR40 8-25, 24-19DWR40-203 8-25, 24-19DWR40-205 24-20DWR40-206 8-26, 24-21DWR6 8-25, 24-19

DWR6-203 8-25, 24-19DWR6-205 24-20DWR6-206 8-26, 24-21DWR625 8-25, 24-19DWR625-203 8-25, 24-19

DWR625-205 24-20DWR625-206 8-26, 24-21

EE121-1/2A 16-16E121-3/8A 16-16E121S-1/2A 16-17

E121S-3/8A 16-17E125S-1/2A 16-17E125S-3/8A 16-17EA122-AA 16-18EA122-BA 16-18

EE49 16-18EF20 8-10ES05F-1/2A 18-4ES06F-1/2A 18-9, 18-11, 18-13, 18-15, 21-9,

21-13

ES06F-11/2A 18-9, 18-11, 18-13, 18-15ES06F-1A 18-13, 18-15ES06F-1B 18-9, 18-11ES16-15 18-21, 18-22ES16-25 18-21, 18-22

ES16-40 18-21, 18-22ES30-1/2A 19-20ES30-1/2B 19-20ES30-11/2A 19-20ES30-11/2B 19-20

ES30-11/4A 19-20ES30-11/4B 19-20ES30-1A 19-20ES30-1B 19-20ES30-2A 19-20

ES30-2B 19-20ES30-3/4A 19-20ES30-3/4B 19-20ES30-3/8A 19-20ES30-3/8B 19-20

ES32-1/2C 19-21ES32-11/2C 19-21ES32-11/4C 19-21ES32-1C 19-21ES32-2C 19-21

ES32-3/4C 19-21ES32-3/8C 19-21ES69Y-100 19-22ES69Y-125 19-22ES69Y-15 19-22

ES69Y-150 19-22ES69Y-20 19-22ES69Y-200 19-22ES69Y-25 19-22ES69Y-32 19-22

ES69Y-40 19-22ES69Y-50 19-22ES69Y-65 19-22ES69Y-80 19-22ES71Y-100 19-23

ES71Y-125 19-23ES71Y-15 19-23ES71Y-150 19-23ES71Y-20 19-23ES71Y-32 19-23

ES71Y-40 19-23ES71Y-50 19-23ES71Y-65 19-23ES71Y-80 19-23ES76S-065A 19-19

ES76S-065C 19-19ES76S-065D 19-19ES76S-065F 19-19ES76S-080A 19-19ES76S-080C 19-19

Page 15: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-14 http://products.ecc.emea.honeywell.com/europe

ES76S-080D 19-19ES76S-080F 19-19ES76S-100A 19-19ES76S-100C 19-19ES76S-100D 19-19

ES76S-100F 19-19ESD05FS 18-6, 18-7ETR2 10-5EVA10RA 4-3EVA1-DANFOSS 12-6, 13-12

EW1000AZ1201 17-2EW1000AZ2001 17-2EW1001AZ1201 17-2EW1001AZ2001 17-2EW1300BF1200 17-4

EW1300BF2000 17-4EW1300BF3600 17-4EW1300BF4600 17-4EW1300BM1200 17-4EW1300BM2000 17-4

EW1300BM3600 17-4EW1300BM4600 17-4EW1301BF1200 17-4EW1301BF2000 17-4EW1301BF3600 17-4

EW1301BF4600 17-4EW1301BM1200 17-4EW1301BM2000 17-4EW1301BM3600 17-4EW1301BM4600 17-4

EW147A1101 17-3EW147A1201 17-3EW147A1301 17-3EW147A2001 17-3EW147P1101 17-3

EW147P1201 17-3EW147P2001 17-3EW148A1101 17-3EW148A1201 17-3EW148A1301 17-3

EW148A2001 17-3EW148P1101 17-3EW148P1201 17-3EW148P2001 17-3EW1700AA5000 17-6

EW1700AA5600 17-6EW1700AA6500 17-6EW1700AA7300 17-6EW1700AA8100 17-6EW1700BM5000 17-7

EW1700BM5600 17-7EW1700BM6500 17-7EW1700BM7300 17-7EW1700BM8100 17-7EW1701AA5000 17-6

EW1701AA5600 17-6EW1701AA6500 17-6EW1701AA7300 17-6EW1701AA8100 17-6EW1701BM5000 17-7

EW1701BM5600 17-7EW1701BM6500 17-7EW1701BM7300 17-7EW1701BM8100 17-7EW447A0100 17-8

EW447A1200 17-8EW447A2000 17-8EW447F1200 17-8EW447M0100 17-8EW447M1200 17-8

EW447M2000 17-8EW447P0100 17-8EW447P1200 17-8EW447P2000 17-8EW448A2800 17-8

EW448A3600 17-8EW448A4600 17-8EW448M2800 17-8EW448M3600 17-8EW448M4600 17-8

EW448P2800 17-8EW448P3600 17-8EW448P4600 17-8EW449A5100 17-8EW449A5900 17-8

EW449A6900 17-8EW449A7700 17-8EW449M5100 17-8EW449M5900 17-8EW449M6900 17-8

EW449M7700 17-8EW449P5100 17-8EW449P5900 17-8EW449P6900 17-8EW449P7700 17-8

EW450A0100 17-9EW450A1200 17-9EW450A2000 17-9EW450F1200 17-9EW450M0100 17-9

EW450M1200 17-9EW450M2000 17-9EW450P0100 17-9EW450P1200 17-9EW450P2000 17-9

EW451A2800 17-9EW451A3600 17-9EW451A4600 17-9EW451M2800 17-9EW451M3600 17-9

EW451M4600 17-9EW451P2800 17-9EW451P3600 17-9EW451P4600 17-9EW452A5100 17-9

EW452A5900 17-9EW452A6900 17-9EW452A7700 17-9EW452M5100 17-9EW452M5900 17-9

EW452M6900 17-9EW452M7700 17-9EW452P5100 17-9EW452P5900 17-9EW452P6900 17-9

EW452P7700 17-9EW457P5000 17-14EW457P5600 17-14EW457P6200 17-14EW457P7300 17-14

EW457P8100 17-14EW457P8503 17-14EW457P8900 17-14EW457P9100 17-14EW457P9203 17-14

EW473P8303 17-15EW473P8725 17-15EW473P9025 17-15EW473P9125 17-15EW473P9225 17-15

EW473P9303 17-15EW473P9425 17-15EW473P9525 17-15EW473P9625 17-15EW473P9925 17-15

EW535M0056 17-7, 17-18EW535M0057 17-18EW535M0058 17-18EW535M0059 17-18EW535M0131 17-18

EW535M5777 17-18EW535M5778 17-18EW535M5780 17-18EW535M5781 17-18EW535M5782 17-18

EW535M5783 17-18EW5451A0100 17-16EW5451A4100 17-16EW5451A7200 17-16EW5451A8303 17-16

EW5451A9100 17-16EW5451A9303 17-16EW7730A1200 17-11EW7730A1400 17-11EW7730A2000 17-11

Page 16: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-15

EW7730A3600 17-11EW7730A4000 17-11EW7730A4600 17-11EW7730A4800 17-11EW7730A5200 17-11

EW7730A6000 17-11EW7730A7000 17-11EW7730A7800 17-11EW7730F1200 17-11EW7730F2000 17-11

EW7730K1200 17-11EW7730K2000 17-11EW7730M1200 17-11EW7730M2000 17-11EW7730M3600 17-11

EW7731A1200 17-11EW7731A2000 17-11EW7731A3600 17-11EW7731A4000 17-11EW7731A4600 17-11

EW7731A4800 17-11EW7731A5200 17-11EW7731A6000 17-11EW7731A7000 17-11EW7731A7800 17-11

EW7731F1200 17-12EW7731F2000 17-12EW7731M1200 17-12EW7731M2000 17-12EW7731M3600 17-12

EW7731M4000 17-12EW7731M4800 17-12EW7731M5200 17-12EW7731M6000 17-12EW7731M7000 17-12

EW7731M7800 17-12EW9100AEZ001 17-5, 17-7EW9100AGZ001 17-7EW9106AFZ001 17-2EW9106AFZ002 17-2

EWA087HY003 17-10, 17-12, 17-16EWA087HY004 17-5, 17-10, 17-12, 17-17EWA087HY005 17-5, 17-10, 17-12, 17-17EWA087HY006 17-5, 17-10, 17-12, 17-17EWA1500035 17-2, 17-3, 17-5, 17-9, 17-12

EWA1500042 17-2, 17-3, 17-5, 17-9, 17-12EWA1500062 17-5, 17-9, 17-12EWA1500072 17-5, 17-9, 17-12EWA3000783 17-13EWA3001303 17-12, 17-16

EWA3001305 17-12, 17-16EWA3001799 17-5, 17-7, 17-13, 17-17EWA3002679 17-16EWA3002680 17-16EWA3002681 17-16

EWA3002682 17-16EWA3002684 17-10, 17-13, 17-16EWA3002685 17-10, 17-13, 17-16EWA3003095A 17-13, 17-17EWA3003095B 17-13, 17-17

EWA3003095C 17-13, 17-17EWA3004406 17-10, 17-13, 17-16EWA3004407 17-16EWA3004612 17-3EWA3007090 17-13, 17-17

EWA3007091 17-13, 17-17EWA3022071 17-13, 17-17EWA3022073 17-13, 17-17EWA3022074 17-13, 17-17EWA3022075 17-13, 17-17

EWA3022076 17-13, 17-17EWA3022079 17-13, 17-17EWA3022097 17-13, 17-17EWA3022101 17-13, 17-17EWA3022102 17-13, 17-17

EWA3022103 17-13, 17-17EWA3022106 17-13, 17-17EWA3023125 17-13, 17-17EWA3023130 17-13, 17-17EWA3026160 17-13, 17-17

EWA3028129 17-13, 17-17EWA354830 17-10, 17-12EWA54200001 17-13EWA54200002 17-13EWA54200003 17-13

EWA54200006 17-13EWA54200011 17-17EWA54200012 17-17EWA54200017 17-13EWA54200026 17-13

EWA54200030 17-13EWA54300011 17-13EWA54300012 17-13EWA630061 17-7EWA630064 17-7

EWP3021322 17-13, 17-17EX-DCM4016 24-25EX-DCM4025 24-25EX-DDCM014 24-27EX-DDCM1 24-27

EX-DDCM16 24-27EX-DDCM1602 24-27EX-DDCM252 24-27EX-DDCM4 24-27EX-DDCM6 24-27

EX-DDCM6002 24-27EX-DDCM662 24-27EX-DGM506 24-30EX-DGM516 24-30EX-DGM525 24-30

EX-DNM10 24-25EX-DNM63 24-25EX-DNS025 24-26EX-DNS06 24-26EX-DNS1 24-26

EX-DNS10 24-26EX-DNS16 24-26EX-DNS3 24-26EX-DNS6 24-26EX-DWR06 24-31

EX-DWR1 24-31EX-DWR16 24-31EX-DWR25 24-31EX-DWR3 24-31EX-DWR40 24-31

EX-DWR6 24-31EX-DWR625 24-31EX-TAM022 23-15EX-TAM150 23-15EX-TAM490 23-15

EX-TAM813 23-15EX-TRM022 23-14EX-TRM150 23-14EX-TRM40 23-14EX-TX023 23-16

EX-TX150 23-16EX-TX490 23-16EX-TXB023 23-16EX-TXB150 23-16EX-TXB490 23-16

EX-VCM095 24-28EX-VCM101 24-28EX-VCM301 24-28EX-VCM4156 24-28EX-VNM111 24-28

EX-VNM301 24-28EX-VNS111 24-29EX-VNS301 24-29

FF42006646 001 1-15, 9-2, 9-3, 9-4, 9-5, 9-6,

11-10, 11-11, 11-12, 11-13, 11-14F42007110 001 11-11, 11-12, 11-13, 11-14

F42007110 002 11-11, 11-12, 11-13, 11-14F42007789 001 1-15, 9-2, 11-10, 11-11, 11-12,

11-13, 11-14F42010971 001 11-4F42010972 001 11-4

F42010977 001 11-4F74CS-1/2AA 19-5F74CS-1/2AC 19-5F74CS-1/2AD 19-5F74CS-11/4AA 19-5

Page 17: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-16 http://products.ecc.emea.honeywell.com/europe

F74CS-11/4AC 19-5F74CS-11/4AD 19-5F74CS-1AA 19-5F74CS-1AC 19-5F74CS-1AD 19-5

F74CS-3/4AA 19-5F74CS-3/4AC 19-5F74CS-3/4AD 19-5F76CS-11/4AA 19-6F76CS-1AA 19-6

F76CS-3/4AA 19-6F76S-1/2AA 19-2F76S-1/2AAM 19-2, 20-8, 20-10F76S-100FA 18-19, 19-18, 20-20F76S-100FB 19-18

F76S-100FC 19-18F76S-100FD 19-18F76S-100FF 19-18F76S-11/2AA 19-2F76S-11/2AAM 19-2, 20-8, 20-10

F76S-11/2EA 19-2F76S-11/4AA 19-2F76S-11/4AAM 19-2, 20-8, 20-10F76S-11/4EA 19-2F76S-125ZFA 19-18

F76S-1AA 19-2F76S-1AAM 19-2, 20-8, 20-10F76S-1EA 19-2F76S-2AA 19-2F76S-2AAM 19-2, 20-8

F76S-2EA 19-2F76S-3/4AA 19-2F76S-3/4AAM 19-2, 20-8, 20-10F76S-3/4EA 19-2F76S-65FA 18-19, 19-18, 20-20

F76S-65FB 19-18F76S-65FC 19-18F76S-65FD 19-18F76S-65FF 19-18F76S-80FA 18-19, 19-18, 20-20

F76S-80FB 19-18F76S-80FC 19-18F76S-80FD 19-18F76S-80FF 19-18FD16-326 24-22

FD16-327 24-22FD300-100A 22-6FD300-150A 22-6FD300-200A 22-6FD300-250A 22-6

FD300-300A 22-6FD300-350A 22-6FD300-400A 22-6FD300-450A 22-6FD300-50A 22-6

FD300-65A 22-6FD300-80A 22-6FF06-1/2AA 19-10FF06-1/2AAM 19-10FF06-1/2EA 19-10

FF06-11/4AA 19-10FF06-11/4AAM 19-10FF06-1AA 19-10FF06-1AAM 19-10FF06-1EA 19-10

FF06-3/4AA 19-10FF06-3/4AAM 19-10FF06-3/4EA 19-10FF20-AC 19-11FF20-DMF 19-11, 19-12, 19-13

FF20-GAC 19-11, 19-12, 19-13FF20-MF 19-11FF40 19-12FF60 19-13FF60-WMF 19-13

FK06-1/2AA 19-36FK06-1/2AAM 19-36FK06-11/4AA 19-36FK06-11/4AAM 19-36FK06-1AA 19-36

FK06-1AAM 19-36FK06-3/4AA 19-36FK06-3/4AAM 19-36FK09S-1/2AA 19-37FK09S-1/2AC 19-37

FK09S-1/2BA 19-38FK09S-1/2EA 19-38FK09S-11/2AA 19-37FK09S-11/2AC 19-37FK09S-11/2BA 19-38

FK09S-11/2EA 19-38FK09S-11/4AA 19-37FK09S-11/4AC 19-37FK09S-11/4BA 19-38FK09S-11/4EA 19-38

FK09S-1AA 19-37FK09S-1AC 19-37FK09S-1BA 19-38FK09S-1EA 19-38FK09S-2AA 19-37

FK09S-2AC 19-37FK09S-2BA 19-38FK09S-2EA 19-38FK09S-3/4AA 19-37FK09S-3/4AC 19-37

FK09S-3/4BA 19-38FK09S-3/4EA 19-38FK74CS-1/2AA 19-28FK74CS-1/2AC 19-29FK74CS-1/2AD 19-29

FK74CS-11/4AA 19-28FK74CS-11/4AC 19-29FK74CS-11/4AD 19-29FK74CS-1AA 19-28FK74CS-1AC 19-29

FK74CS-1AD 19-29FK74CS-3/4AA 19-28FK74CS-3/4AC 19-29FK74CS-3/4AD 19-29FK76CS-114AA 19-30

FK76CS-1AA 19-30FK76CS-3/4AA 19-30FKN74CS-1A 19-33FKN74CS-1C 19-33FKN76CS-1A 19-35

FN09S-1/2A 19-14FN09S-1/2AM 19-14FN09S-11/2A 19-14FN09S-11/2AM 19-14FN09S-1A 19-14

FN09S-1AM 19-14FN09S-1AMN 19-14FN09S-1AN 19-14FN74CS-1A 19-8FN76CS-1A 19-9

FR124-3/4A 16-6FS100V 13-16FT09RS-11/2A 19-4, 19-15, 19-26, 19-38FT09RS-1A 19-4, 19-7, 19-9, 19-15, 19-26,

19-31, 19-35, 19-38

FT6960-18 9-12, 23-4FT6960-18F 9-12, 23-4FT6960-30 9-12, 23-4FT6960-30F 9-12, 23-4FT6960-60 9-12, 23-4

FT6960-60F 9-12, 23-4FT6961-18 9-12, 23-4FT6961-18F 9-12, 23-4FT6961-30 9-12, 23-4FT6961-30F 9-12, 23-4

FT6961-60 9-12, 23-4FT6961-60F 9-12, 23-4FV300-100A 22-7FV300-150A 22-7FV300-200A 22-7

FV300-250A 22-7FV300-300A 22-7FV300-350A 22-7FV300-400A 22-7FV300-450A 22-7

FV300-50A 22-7FV300-65A 22-7FV300-80A 22-7FY30-1/2A 18-16, 19-20FY30-1/2B 19-20

Page 18: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-17

FY30-11/2A 18-16, 19-20FY30-11/2B 19-20FY30-11/4A 18-16, 19-20FY30-11/4B 19-20FY30-1A 18-16, 19-20

FY30-1B 19-20FY30-2A 18-16, 19-20FY30-2B 19-20FY30-3/4A 18-16, 19-20FY30-3/4B 19-20

FY30-3/8A 18-16, 19-20FY30-3/8B 19-20FY32-1/2C 19-21FY32-1/4C 19-21FY32-11/2C 19-21

FY32-11/4C 19-21FY32-1C 19-21FY32-2C 19-21FY32-3/4C 19-21FY32-3/8C 19-21

FY69P-100A 18-19, 19-22, 20-18, 20-20FY69P-125A 18-19, 19-22FY69P-150A 18-19, 19-22, 20-18, 20-20FY69P-15A 19-22FY69P-200A 18-19, 19-22, 20-20

FY69P-20A 19-22FY69P-25A 19-22FY69P-32A 19-22FY69P-40A 19-22FY69P-50A 18-18, 19-22

FY69P-65A 18-19, 19-22, 20-18, 20-20FY69P-80A 18-19, 19-22, 20-18, 20-20FY71P-100B 19-23FY71P-125B 19-23FY71P-150B 19-23

FY71P-15B 19-23FY71P-20B 19-23FY71P-32B 19-23FY71P-40B 19-23FY71P-50B 19-23

FY71P-65B 19-23FY71P-80B 19-23

GG12-100 23-3, 27-2G12-150 27-2G12-200 27-2

G12-250 23-3, 27-2GB12 26-2GB12VA 26-3GB20 26-2GB20VA 26-3

GB25 26-2GB25VA 26-3GF20 8-10GK13 26-3GK20 26-3

GK25 26-3GK25F 26-3GK32 26-3GK32F 26-3GK40 26-3

GK40F 26-3GK50 26-3GK50F 26-3GT4 2-8

HH100-1/2D 13-35, 13-36, 13-39H6045A1002 10-2, 28-2H6120A1000 10-2, 28-2

H615A2015 10-2H615A2077 10-2H7012A1009 8-15H7012B1008 8-15H7012B1023 3-6

H7012B1024 8-15H7012B1030 8-15H7012BALCOKIT 8-15H7015B1060 8-16H7015B1080 8-16

H7508A1026 8-16H7508A1030 8-16H7508A1042 8-16HB85 12-3HCA1VEL 4-3, 12-6, 13-12

HCC80 12-3, 12-4HCC80R 12-3, 12-4HCD6003 24-23HCD6010 24-23HCD6050 24-23

HCD6150 24-23HCE80 12-3, 12-4HCE80R 12-3, 12-4HCF82 12-3, 12-4HCS80 12-3, 12-4

HCW80 12-7HCW82 12-3, 12-4HDI10 8-2, 8-37HE25 6-11, 6-12HE32 6-11

HF49-1A 16-18HGK3 10-3HGS80 12-3HM80 12-3, 12-5HMC80 12-5

HMC82 12-5HPF80 12-4HR10F 13-12HR40 13-12HR40F 13-12

HR80 12-3, 12-5, 12-6HRA80 12-3, 12-4HRD80 12-6HS10S-1/2AA 19-24HS10S-1/2AAM 19-25

HS10S-11/2AA 19-24HS10S-11/2AAM 19-25HS10S-11/4AA 19-24HS10S-11/4AAM 19-25HS10S-1AA 19-24

HS10S-1AAM 19-25HS10S-2AA 19-24HS10S-2AAM 19-25HS10S-3/4AA 19-24HS10S-3/4AAM 19-25

HS74CA-11/4AA 19-27HS74CA-11/4AC 19-27HS74CA-11/4AD 19-27HS74CA-1AA 19-27HS74CA-1AC 19-27

HS74CA-1AD 19-27HS74CA-3/4AA 19-27HS74CA-3/4AC 19-27HS74CA-3/4AD 19-27HSS-DPS 8-40

HTS10 12-6HTU10 12-6HU01 12-6, 13-12HU02 12-6, 13-12HVAC03C2 7-7

HVAC03C5 7-7HVAC04C2 7-7HVAC04C5 7-7HVAC05C2 7-7HVAC05C5 7-7

HVAC07C2 7-7HVAC07C5 7-7HVAC09C2 7-7HVAC09C5 7-7HVAC12C2 7-7

HVAC12C5 7-7HVAC16C2 7-7HVAC16C5 7-7HVAC23C2 7-7HVAC23C5 7-7

HVAC31C2 7-7HVAC31C5 7-7HVAC38C2 7-7HVAC38C5 7-7HVAC400-110-21 7-5

Page 19: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-18 http://products.ecc.emea.honeywell.com/europe

HVAC400-110-54 7-5HVAC400-11P-21 7-5HVAC400-11P-54 7-5HVAC400-132-21 7-5HVAC400-132-54 7-5

HVAC400-15P-21 7-5HVAC400-15P-54 7-5HVAC400-160-21 7-5HVAC400-160-54 7-5HVAC400-18P-21 7-5

HVAC400-18P-54 7-5HVAC400-1P1-21 7-5HVAC400-1P1-54 7-5HVAC400-1P5-21 7-5HVAC400-1P5-54 7-5

HVAC400-22P-21 7-5HVAC400-22P-54 7-5HVAC400-2P2-21 7-5HVAC400-2P2-54 7-5HVAC400-30P-21 7-5

HVAC400-30P-54 7-5HVAC400-37P-21 7-5HVAC400-37P-54 7-5HVAC400-3P0-21 7-5HVAC400-3P0-54 7-5

HVAC400-45P-21 7-5HVAC400-45P-54 7-5HVAC400-4P0-21 7-5HVAC400-4P0-54 7-5HVAC400-55P-21 7-5

HVAC400-55P-54 7-5HVAC400-5P5-21 7-5HVAC400-5P5-54 7-5HVAC400-75P-21 7-5HVAC400-75P-54 7-5

HVAC400-7P5-21 7-5HVAC400-7P5-54 7-5HVAC400-90P-21 7-5HVAC400-90P-54 7-5HVAC46C2 7-7

HVAC46C5 7-7HVAC61C2 7-7HVAC61C5 7-7HVAC-DOOR-KIT 7-12HVAC-FAN-4 7-13

HVAC-FAN-5 7-13HVAC-FAN-6 7-13HVAC-FAN-7 7-13HVAC-HAND-KIT 7-12HVAC-HMI-A 7-12

HVAC-HMI-S 7-12HVS80 12-6

I

IF-LON 2-3iLON10EU 2-13IRA-AD 4-3

KK42008268-001 11-10K430D 24-32, 25-6K480D 24-32, 25-6

KB191-3/4 21-16, 21-18, 21-20KF06-1/2A 19-11, 19-36KF06-1A 19-11, 19-36KF11S-11/2A 19-4, 19-15, 19-26, 19-39KF11S-1A 19-4, 19-7, 19-9, 19-15, 19-26,

19-31, 19-35, 19-39KF21 27-4KF31 27-4KF74-1A 19-27KF74CS-1A 19-5, 19-8, 19-29, 19-33

KH11S-1A 19-4, 19-7, 19-9, 19-15, 19-26, 19-31, 19-35, 19-39

KH49 16-18KSL230 29-3KSL24 29-3

KSW230 8-40, 29-4KSW24 8-40, 29-4KTF20 3-3, 3-6, 8-8KTF20-B 8-8

LL6188A2002 9-10L6188A2010 9-10L6188A2036 9-10

L6188A2044 9-10L6188A2085 9-10L6188A2093 9-10L6188B2018 9-10L6188B2026 9-10

L6188B2034 9-10L6188B2042 9-10L6188B2059 9-10L6188C2008 9-10L6188C2016 9-10

L641A1039 11-15L641B1004 9-3, 9-4, 9-9, 11-15L641B1012 11-15LF10 8-9LF20 8-9

LF20-C 8-9LSU25-18 6-11, 6-12LSU25-22 6-11, 6-12LSU25-28 6-11, 6-12LSU32-22 6-11

LSU32-28 6-11LSU32-35 6-11

MM07K-A10 20-3, 20-5M07K-A16 18-25, 20-3, 20-5, 22-5M07K-A25 20-3, 20-5

M07K-A4 20-3, 20-5M07M-A10 18-9, 18-11, 18-13, 18-15, 18-17,

18-20, 18-23, 19-36, 19-39, 20-3, 21-9, 21-11, 21-13

M07M-A16 18-9, 18-11, 18-13, 18-15, 18-19,

19-7, 19-9, 19-27, 19-31, 19-35, 19-36, 20-3, 21-9, 21-11, 21-13, 22-3, 22-15

M07M-A25 18-9, 18-11, 18-13, 18-15, 19-7, 20-3, 21-9, 21-11, 21-13

M07M-A4 16-10, 16-12, 18-9, 18-11, 18-13,

18-15, 18-19, 19-36, 20-3, 21-9, 21-11, 21-13

M08M16 21-7, 21-9M38K-A10 18-3, 18-6, 18-16, 18-21, 18-22, 19-26M38K-A16 18-16, 18-21, 18-22, 19-26

M38K-A25 18-16, 18-21, 18-22, 19-26M38K-A4 18-3, 18-6, 18-16, 18-21, 18-22M38T-A10 18-7M39K-A10 16-8M39M-A10 18-17

M39M-A16 18-17, 18-20, 22-10M5003A1001 14-13M5003A1002 14-13M5410C1001 4-4M5410L1001 4-4

M6061A1013 4-11M6061A1021 4-11M6061A1039 4-11M6061A1047 4-11M6061L1019 4-11

M6061L1027 4-11M6061L1035 4-11M6061L1043 4-11M6063A1003 4-11M6063A4007 4-11

M6063L1009 4-11M6063L4003 4-11M6410C2023 4-4M6410C2031 4-5M6410C4029 4-4

M6410C4037 4-5M6410L2023 4-4M6410L2031 4-5M6410L4029 4-4M6410L4037 4-5

Page 20: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-19

M6422L1003 4-12M7061E1012 4-12M7061E1020 4-12M7410A1001 4-3, 14-9M7410C1007 4-4

M7410C1015 4-5M7410E1002 4-5M7410E1028 4-5M7410E2026 4-5M7410E2034 4-5

M7410E4022 4-5M7410E4030 4-5M7410E5001 14-9M7410G1008 4-10, 14-9M7410G1016 4-10

M7410G1024 4-10M74CS-A16 19-5, 19-8, 19-29, 19-33M76K-A16 19-4, 19-19MAU8/MS 24-32, 25-6MAU8/NST 24-32, 25-6

MF126-A4 16-7, 16-8ML6420A3007 4-7ML6420A3015 4-7ML6420A3023 4-7ML6420A3031 4-7

ML6420A3072 4-7ML6421A3005 4-8ML6421A3013 4-8ML6421B3004 4-9ML6421B3012 4-9

ML6425A3006 4-7ML6425A3014 4-7ML6425B3005 4-7ML6425B3021 4-7ML6435B1008 4-6

ML6435B1016 4-6ML7420A6009 4-8ML7420A6017 4-8ML7420A6025 4-8ML7421A3004 4-9

ML7421B3003 4-9ML7425A6008 4-8ML7425B6007 4-8ML7430E1005 4-6ML7435E1004 4-6

MT010-3MN 4-3MT010-N 4-3MT4-024-NC 4-2MT4-024-NC-2.5M 4-2MT4-024-NO 4-2

MT4-024-NO-2.5M 4-2MT4-024S-NC 4-2MT4-024S-NO 4-2MT4-230-NC 4-2, 12-3, 12-5MT4-230-NC-2.5M 4-2

MT4-230-NO 4-2, 12-3, 12-5MT4-230-NO-2.5M 4-2MT4-230S-NC 4-2MT4-230S-NO 4-2MT8-024-NC 4-2

MT8-024-NC-2.5M 4-2MT8-024-NO 4-2MT8-024-NO-2.5M 4-2MT8-024S-NC 4-2MT8-024S-NO 4-2

MT8-230-NC 4-2MT8-230-NC-2.5M 4-2MT8-230-NO 4-2MT8-230-NO-2.5M 4-2MT8-230S-NC 4-2

MT8-230S-NO 4-2MT-ADAPT-HP 4-3MT-ADAPT-HW 4-3MT-CABLE-1.5M 4-3MT-CABLE-10M 4-3

MT-CABLE-2.5M 4-3MT-CABLE-5M 4-3MT-CLIP 4-2MV300-100A 22-8MV300-100AA 22-8

MV300-100B 22-9MV300-100BB 22-9MV300-150A 22-8MV300-150AA 22-8MV300-150B 22-9

MV300-150BB 22-9MV300-200A 22-8MV300-200AA 22-8MV300-200B 22-9MV300-200BB 22-9

MV300-250A 22-8MV300-250AA 22-8MV300-250B 22-9MV300-250BB 22-9MV300-300A 22-8

MV300-300AA 22-8MV300-300B 22-9MV300-300BB 22-9MV300-350A 22-8MV300-350AA 22-8

MV300-350B 22-9MV300-350BB 22-9MV300-400A 22-8MV300-400AA 22-8MV300-400B 22-9

MV300-400BB 22-9MV300-450A 22-8MV300-450AA 22-8MV300-450B 22-9MV300-450BB 22-9

MV300-50A 22-8MV300-50AA 22-8MV300-50B 22-9MV300-50BB 22-9MV300-65A 22-8

MV300-65AA 22-8MV300-65B 22-9MV300-65BB 22-9MV300-80A 22-8MV300-80AA 22-8

MV300-80B 22-9MV300-80BB 22-9MVC-40-AC3 2-4MVC-80-AC1 2-4MVC-80-AC2 2-4

NN05010 4-13N05010-SW2 4-13N05230-2POS 4-13

N0524 4-13N0524-SW2 4-13N10010 4-13N10010-SW2 4-13N10230-2POS 4-13

N1024 4-13N1024-SW2 4-13N12-100 23-3, 27-2N12-150 27-2N12-200 27-2

N12-250 23-3, 27-2N20010A 4-14N20010A-SW2 4-14N20230A 4-14N20230A-SW2 4-14

N2024A 4-14N2024A-SW2 4-14N34010A 4-14N34230A 4-14N3424A 4-14

NK295C-1/2A 16-9NK300-1/2A 16-10, 16-19NK300soft-1/2A 16-12NK300soft-1/2AZ25 16-12NK300T-1/2A 16-11

NK300T-1/2ABA 16-11NK300T-1/2ACA 16-11NPT1 24-32, 25-6NX-FAN-4 7-13NX-FAN-5 7-13

NX-FAN-6 7-13NX-FAN-7 7-13NXIP54FR4 7-13NXIP54FR5 7-13NXIP54FR6 7-13

Page 21: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-20 http://products.ecc.emea.honeywell.com/europe

NXL0001V35C1N0 7-8NXL0002V32C1N0 7-8NXL0002V35C1N0 7-8NXL0003V32C1N1 7-8NXL0003V35C1N1 7-8

NXL0004V32C1N1 7-8NXL0004V35C1N1 7-8NXL0005V35C1N1 7-8NXL0006V32C1N1 7-8NXLOPTAA 7-11

NXLPANC 7-12NXLPANRS 7-11NXLRFIV12 7-8NXLRFIV35 7-8NXOPTA1 7-11

NXOPTB2 7-11NXOPTB8 7-11NXOPTC2 7-11NXOPTC3 7-11NXOPTC6 7-11

NXOPTC7 7-11NXOPTCI 7-11NXOPTCJ 7-11NXPANA 7-12NXPANG 7-12

NXS0003V35A2H1 7-9NXS0003V35A5H1 7-10NXS0004V35A2H1 7-9NXS0004V35A5H1 7-10NXS0005V35A2H1 7-9

NXS0005V35A5H1 7-10NXS0007V35A2H1 7-9NXS0007V35A5H1 7-10NXS0009V35A2H1 7-9NXS0009V35A5H1 7-10

NXS0012V35A2H1 7-9NXS0012V35A5H1 7-10NXS0016V35A2H1 7-9NXS0016V35A5H1 7-10NXS0022V35A2H1 7-9

NXS0022V35A5H1 7-10NXS0031V35A2H1 7-9NXS0031V35A5H1 7-10NXS0038V35A2H1 7-9NXS0038V35A5H1 7-10

NXS0045V35A2H1 7-9NXS0045V35A5H1 7-10NXS0061V35A2H1 7-9NXS0061V35A5H1 7-10NXS0072V35A2H0 7-9

NXS0072V35A5H0 7-10NXS0087V35A2H0 7-9NXS0087V35A5H0 7-10NXS0105V35A2H0 7-9NXS0105V35A5H0 7-10

NXS0140V35A2H0 7-9NXS0140V35A5H0 7-10NXS0168V35A2H0 7-9NXS0168V35A5H0 7-10NXS0205V35A2H0 7-9

NXS0205V35A5H0 7-10NXS0260V35A2H0 7-9NXS0260V35A5H0 7-10NXS0310V35A2H0 7-9NXS0310V35A5H0 7-10

NXS0385V35A2L0 7-10NXS0460V35A2L0 7-10NXS0590V35A2L0 7-10NXS0650V35A2L0 7-10NXS0730V35A2L0 7-10

OOPTB1 7-11OPTB4 7-11OPTB5 7-11

OPTB9 7-11OPTBF 7-11OPTC4 7-11OT112M-3/4D 13-50, 13-51, 13-52OT112M-3/4F 13-50, 13-51, 13-52

OT112M-3/4F2 13-50, 13-51, 13-52OT112M-3/4G 13-50, 13-51, 13-52OT112M-3/4H 13-50, 13-51, 13-52OT113M-3/4D 13-50, 13-51OT113M-3/4F 13-50, 13-51

OT113M-3/4H 13-50, 13-51OT114M-3/4B 13-50, 13-51OT114M-3/4C 13-50, 13-51OT114M-3/4D 13-50, 13-51OT114M-3/4E 13-50, 13-51

OT114M-3/4F 13-50, 13-51OT114M-3/4H 13-50, 13-51

PP100-100 27-2P100-150 27-2P100-200 27-2

P100-250 27-2P2 9-11, 9-22, 23-5, 23-6, 23-7, 23-14,

23-15, 23-16, 24-32, 25-6P2-TVS12-400100 23-3P2-TVS12-400250 23-3

P300-L 16-11, 16-12, 16-19P300-S 16-11, 16-12, 16-19PA1 8-39, 29-2PC300-100A 22-10PC300-150A 22-10

PC300-200A 22-10PC300-250A 22-10PC300-300A 22-10PC300-350A 22-10PC300-400A 22-10

PC300-450A 22-10PC300-65A 22-10PC300-80A 22-10PCC10KIT 2-13PCLTA21 2-13

PE49 16-18PS300-100A 22-11PS300-150A 22-11PS300-200A 22-11PS300-250A 22-11

PS300-300A 22-11PS300-350A 22-11PS300-400A 22-11PS300-450A 22-11PS300-50A 22-11

PS300-65A 22-11PS300-80A 22-11PSHDB0012 8-28, 24-7PSHDB0032 8-28, 24-7PSHDB0062 8-28, 24-7

PSHDB0202 8-28, 24-7PSHDM1002 8-28, 24-7PSHDM3002 8-28, 24-7PSHRB0011 8-32, 24-6PSHRB0041 8-32, 24-6

PSHRB0101 8-32, 24-6PSHRB0161 8-32, 24-6PSHRB0251 8-32, 24-6PSHRB0401 8-32, 24-6PSHRV1011 8-32, 24-6

PST001RG12S 8-31, 24-4PST001RG12S-R 8-31, 24-5PST001RG34F 8-29, 24-2PST001RG34F-R 8-30, 24-3PST002AG12S 8-31, 24-4

PST002AG12S-R 8-31, 24-5PST002AG34F 8-29, 24-2PST002AG34F-R 8-30, 24-3PST002RG12S 8-31, 24-4PST002RG12S-R 8-31, 24-5

PST002RG34F 8-29, 24-2PST002RG34F-R 8-30, 24-3PST004RG12S 8-31, 24-4PST004RG12S-R 8-31, 24-5PST004RG34F 8-29, 24-2

PST004RG34F-R 8-30, 24-3PST010AG12S 8-31, 24-4PST010AG12S-R 8-31, 24-5PST010AG34F 8-29, 24-2PST010AG34F-R 8-30, 24-3

Page 22: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-21

PST010RG12S 8-31, 24-4PST010RG12S-R 8-31, 24-5PST010RG34F 8-29, 24-2PST010RG34F-R 8-30, 24-3PST025RG12S 8-31, 24-4

PST025RG12S-R 8-31, 24-5PST025RG34F 8-29, 24-2PST025RG34F-R 8-30, 24-3PST060RG12S 8-31, 24-4PST060RG12S-R 8-31, 24-5

PST100RG12S 8-31, 24-4PST100RG12S-R 8-31, 24-5PST250RG12S 8-31, 24-4PST250RG12S-R 8-31, 24-5PST600RG12S 8-31, 24-4

PST600RG12S-R 8-31, 24-5PSTM250RG12S 8-31, 24-4PSTM250RG12S-R 8-31, 24-5PSTM250RG34F 8-29, 24-2PSTM250RG34F-R 8-30, 24-3

PSTM400RG12S 8-31, 24-4PSTM400RG12S-R 8-31, 24-5PSTM400RG34F 8-29, 24-2PSTM400RG34F-R 8-30, 24-3PSTM600RG12S 8-31, 24-4

PSTM600RG12S-R 8-31, 24-5PSTM600RG34F 8-29, 24-2PSTM600RG34F-R 8-30, 24-3PSTV01RG12S 8-31, 24-4PSTV01RG12S-R 8-31, 24-5

PSTV01RG34F 8-29, 24-2PSTV01RG34F-R 8-30, 24-3PTHDB0012A2 8-35, 25-3PTHDB0012V3 8-35, 25-3PTHDB0032A2 8-35, 25-3

PTHDB0032V3 8-35, 25-3PTHDB0062A2 8-35, 25-3PTHDB0062V3 8-35, 25-3PTHDB0202A2 8-35, 25-3PTHDB0202V3 8-35, 25-3

PTHDM1002A2 8-35, 25-3PTHDM1002V3 8-35, 25-3PTHDM3002A2 8-35, 25-3PTHDM3002V3 8-35, 25-3PTHRB0011A2 8-33, 25-2

PTHRB0011V3 8-33, 25-3PTHRB0041A2 8-33, 25-2PTHRB0041V3 8-33, 25-3PTHRB0101A2 8-33, 25-2PTHRB0101V3 8-33, 25-3

PTHRB0161A2 8-33, 25-2PTHRB0161V3 8-33, 25-3PTHRB0251A2 8-33, 25-2PTHRB0251V3 8-33, 25-3PTHRB0401A2 8-33, 25-2

PTHRB0401V3 8-33, 25-3PTHRV1011A2 8-33, 25-2PTHRV1011V3 8-33, 25-3PTSDB0012V3 8-35, 25-3PTSDB0032V3 8-35, 25-3

PTSDB0062V3 8-35, 25-3PTSDB0202V3 8-35, 25-3PTSDM1002V3 8-35, 25-3PTSDM3002V3 8-35, 25-3PTSRB0011A2 8-32, 25-2

PTSRB0011A3 8-33, 25-2PTSRB0011V3 8-33, 25-2PTSRB0041A2 8-32, 25-2PTSRB0041A3 8-33, 25-2PTSRB0041V3 8-33, 25-2

PTSRB0101A2 8-32, 25-2PTSRB0101A3 8-33, 25-2PTSRB0101V3 8-33, 25-2PTSRB0161A2 8-32, 25-2PTSRB0161A3 8-33, 25-2

PTSRB0161V3 8-33, 25-2PTSRB0251A2 8-32, 25-2PTSRB0251A3 8-33, 25-2PTSRB0251V3 8-33, 25-2PTSRB0401A2 8-32, 25-2

PTSRB0401A3 8-33, 25-2PTSRB0401V3 8-33, 25-2PTSRV1011A2 8-32, 25-2PTSRV1011A3 8-33, 25-2PTSRV1011V3 8-33, 25-2

PW3 2-7

QQ6360A1025 1-15, 9-2Q6371A1006 10-4Q6371C1002 10-4

Q6371C1010 10-4Q979A1020 1-15, 9-2Q979B1029 1-15, 9-2Q979C1036 1-15, 9-2

RR1/MS 9-11, 23-6, 23-15R1/NST 23-15R1/Nst 9-11, 23-6

R10/MS 23-7, 23-16R10/NST 23-7, 23-16R12-100 23-3, 27-2R12-150 27-2R12-200 27-2

R12-250 23-3, 27-2R2/MS 9-11, 23-6, 23-15R2/NST 23-15R2/Nst 9-11, 23-6R20/MS 23-7, 23-16

R20/NST 23-7, 23-16R295-1/2A 20-2R295-1/2B 20-2R295-1/2C 20-2R295-1/2D 20-2

R295-11/2A 20-2R295-11/2B 20-2R295-11/2C 20-2R295-11/2D 20-2R295-11/4A 20-2

R295-11/4B 20-2R295-11/4C 20-2R295-11/4D 20-2R295-1A 20-2R295-1B 20-2

R295-1C 20-2R295-1D 20-2R295-2A 20-2R295-2B 20-2R295-2C 20-2

R295-2D 20-2R295-3/4A 20-2R295-3/4B 20-2R295-3/4C 20-2R295-3/4D 20-2

R295H-1/2A 20-3R295H-11/2A 20-3R295H-11/4A 20-3R295H-1A 20-3R295H-2A 20-3

R295H-3/4A 20-3R295HP-100FA 20-16R295HP-125FA 20-16R295HP-150FA 20-16R295HP-200FA 20-16

R295HP-65FA 20-16R295HP-80FA 20-16R295P-100FA 20-15R295P-100FB 20-15R295P-100FC 20-15

R295P-125FA 20-15R295P-125FB 20-15R295P-150FA 20-15R295P-150FB 20-15R295P-200FA 20-15

R295P-200FB 20-15R295P-65FA 20-15R295P-65FB 20-15R295P-65FC 20-15R295P-80FA 20-15

Page 23: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-22 http://products.ecc.emea.honeywell.com/europe

R295P-80FB 20-15R295P-80FC 20-15R295SA-1/2A 20-4R295SA-1/2B 20-4R295SA-1/2C 20-4

R295SA-1/2D 20-5R295SA-11/2A 20-4R295SA-11/2B 20-4R295SA-11/2C 20-4R295SA-11/2D 20-5

R295SA-11/4A 20-4R295SA-11/4B 20-4R295SA-11/4C 20-4R295SA-11/4D 20-5R295SA-1A 20-4

R295SA-1B 20-4R295SA-1C 20-4R295SA-1D 20-5R295SA-2A 20-4R295SA-2B 20-4

R295SA-2C 20-4R295SA-2D 20-5R295SA-3/4A 20-4R295SA-3/4B 20-4R295SA-3/4C 20-4

R295SA-3/4D 20-5R295SP-100FA 20-17R295SP-100FB 20-17R295SP-100FC 20-17R295SP-125FA 20-17

R295SP-125FB 20-17R295SP-150FA 20-17R295SP-150FB 20-17R295SP-200FA 20-17R295SP-200FB 20-17

R295SP-65FA 20-17R295SP-65FB 20-17R295SP-65FC 20-17R295SP-80FA 20-17R295SP-80FB 20-17

R295SP-80FC 20-17R3/MS 9-11, 23-6, 23-15R4 9-11, 23-6, 23-15R453HY002 4-3R5 9-11, 23-6, 23-15

R6 23-7, 23-16R6660D1009 11-3, 12-3, 12-5, 12-7R6660D1017 11-3R6660D1025 11-3R6660D1033 11-3

R6660D1041 11-3R6660D1058 11-3R7 23-7, 23-16R7426A2006 3-6R7426A2014 3-7

R7426B2004 3-8R7426B2012 3-9R7426C2002 3-8R7426C2010 3-9R7426D2000 3-10

R8810A1018 12-3RF20 3-3, 8-5, 9-9RF20A 3-5RF21 27-4RF31 27-4

RFCA-SR10 9-8RGT240 9-20RIN-APU24-2 2-5RN1/MS 9-11, 23-6, 23-15RN1/NST 9-11, 23-6, 23-15

RN10/MS 23-7, 23-16RN10/NST 23-7, 23-16RN2/MS 9-11, 23-6, 23-15RN2/NST 9-11, 23-6, 23-15RN20/MS 23-7, 23-16

RN20/NST 23-7, 23-16RS232C2M 7-11RS232C-4M 7-11RT7070A2008 1-12RT70-HRD20-WALL 1-12

RV181-1/2A 20-22RV181-1/2B 20-22RV181-1/2K 20-22RV181-11/2A 20-22RV181-11/2B 20-22

RV181-11/4A 20-22RV181-11/4B 20-22RV181-1A 20-22RV181-1B 20-22RV181-2A 20-22

RV181-2B 20-22RV181-3/4A 20-22RV181-3/4B 20-22RV181-3/4K 20-22RV260-3/4AA 20-23

RV260-3/4AS 20-23RV277-1/2A 19-3, 19-11, 19-38, 20-24RV277-11/2A 19-3, 19-38, 20-24RV277-11/4A 19-3, 19-7, 19-9, 19-11, 19-31,

19-35, 19-38, 20-24

RV277-1A 19-3, 19-7, 19-9, 19-11, 19-31, 19-35, 19-38, 20-24

RV277-2A 19-3, 19-38, 20-24RV277-3/4A 19-3, 19-7, 19-9, 19-11, 19-31,

19-35, 19-38, 20-24

RV280-1/2A 20-25RV280-11/2A 20-25RV280-11/4A 20-25RV280-1A 20-25RV280-2A 20-25

RV280-3/4A 20-25RV281-1/2A 20-26RV281-1/2B 20-26RV281-1/2E 20-26RV281-11/2A 20-26

RV281-11/2B 20-26RV281-11/2E 20-26RV281-11/4A 20-26RV281-11/4B 20-26RV281-11/4E 20-26

RV281-1A 20-26RV281-1B 20-26RV281-1E 20-26RV281-2A 20-26RV281-2B 20-26

RV281-2E 20-26RV281-3/4A 20-26RV281-3/4B 20-26RV281-3/4E 20-26RV283P-100A 18-18, 19-19, 20-28

RV283P-100B 20-28RV283P-125A 18-18, 20-28RV283P-125B 20-28RV283P-150A 18-18, 20-28RV283P-150B 20-28

RV283P-200A 18-18, 20-28RV283P-200B 20-28RV283P-250A 20-28RV283P-250B 20-28RV283P-300A 20-28

RV283P-300B 20-28RV283P-40A 20-28RV283P-40B 20-28RV283P-50A 18-18, 20-28RV283P-50B 20-28

RV283P-65A 18-18, 19-19, 20-28RV283P-65B 20-28RV283P-80A 18-18, 19-19, 20-28RV283P-80B 20-28RV284-1/2A 20-27

RV284-15B 20-27RV284-1A 20-27RV284-20B 20-27RV284-25B 20-27RV284-3/4A 20-27

RV295-1/2 20-8, 20-11RV295-1/2E 20-8, 20-11RV295-11/4 20-8, 20-11RV295-11/4E 20-11

SS03010 4-15S03010-SW1 4-15S03230-2POS 4-15

Page 24: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-23

S03230-2POS-SW1 4-15S0324-2POS 4-15S0324-2POS-SW1 4-15S05010 4-15S05010-SW1 4-15

S05230-2POS 4-15S05230-2POS-SW1 4-15S0524-2POS 4-15S0524-2POS-SW1 4-15S06K-1/4 16-7, 16-10, 16-12, 18-3, 18-4,

18-6, 18-9, 18-11, 18-13, 18-15, 20-24, 21-7, 21-9, 21-11, 21-13

S06M-1/4 18-7, 18-21, 18-22, 20-25S1 9-22, 23-5, 23-7, 23-14, 23-16S10010 4-16

S10010-SW2 4-16S10230-2POS 4-16S10230-2POS-SW2 4-16S1024-2POS 4-16S1024-2POS-SW2 4-16

S20010 4-16S20010-SW2 4-16S20230-2POS 4-16S20230-2POS-SW2 4-16S2024-2POS 4-16

S2024-2POS-SW2 4-16S245B-112ZA*... 21-4S245B-112ZB*... 21-4S245B-114ZA*... 21-4S245B-114ZB*... 21-4

S245B-12ZA*... 21-4S245B-12ZB*... 21-4S245B-1ZA*... 21-4S245B-1ZB*... 21-4S245B-2ZA*... 21-4

S245B-2ZB*... 21-4S245B-34ZA*... 21-4S245B-34ZB*... 21-4S245S-112Z*... 21-5S245S-114Z*... 21-5

S295STN 20-12, 20-13S295STN-11/2 20-14S4390A1004 1-15, 9-2S6040A1003 8-39, 29-2S6065A1003 8-39, 29-2

S6065A2001 8-39, 29-2S7014A1004 8-18S7014B1000 8-18S7014C1009 8-18SAF25 8-38

SCS-12 3-3SDBAM1 8-27, 24-23SDBAM16 8-27, 24-23SDBAM2.5 8-27, 24-23SDBAM32 8-27, 24-23

SDBAM6 8-27, 24-23SDBAM625 8-27, 24-23SDC12-31N 3-3SDC12-31PM 3-2SDC12-31PMN 3-3

SDC12-31WM 3-2SDC3-10N 3-3SDC3-10PM 3-2SDC3-10PMN 3-3SDC3-10WM 3-2

SDC3-40N 3-3SDC3-40PM 3-2SDC3-40PMN 3-3SDC3-40WM 3-2SDC7-21N 3-3

SDC7-21PM 3-2SDC7-21PMN 3-3SDC7-21WM 3-2SDC9-21N 3-3SDC9-21PM 3-2

SDC9-21WM 3-2SDW10BCUK 3-3SDW10EE 3-3SDW10WE 3-3SDW30 3-3

SDW30N 3-3SG150-1/2AA 21-6SG150-1/2AB 21-6SG150-1/2AC 21-6SG150-1/2EA 21-6

SG150-1/2EB 21-7SG150-1/2EC 21-7SG150-3/4AA 21-6SG150-3/4AB 21-6SG150-3/4AC 21-6

SG150-3/4EA 21-6SG150-3/4EB 21-7SG150-3/4EC 21-7SG150D-1/2AA 21-8SG150D-1/2AB 21-8

SG150D-1/2AC 21-8SG150D-1/2EA 21-8SG150D-1/2EB 21-9SG150D-1/2EC 21-9SG150D-3/4AA 21-8

SG150D-3/4AB 21-8SG150D-3/4AC 21-8SG150D-3/4EA 21-8SG150D-3/4EB 21-9SG150D-3/4EC 21-9

SG160S-1/2AA 21-10SG160S-1/2AB 21-10SG160S-1/2AC 21-10SG160S-1AA 21-10SG160S-1AB 21-10

SG160S-1AC 21-10SG160S-1EA 21-10SG160S-1EB 21-11SG160S-1EC 21-11SG160S-3/4AA 21-10

SG160S-3/4AB 21-10SG160S-3/4AC 21-10SG160S-3/4EA 21-10SG160S-3/4EB 21-11SG160S-3/4EC 21-11

SG160SD-1/2AA 21-12SG160SD-1/2AB 21-12SG160SD-1/2AC 21-12SG160SD-1AA 21-12SG160SD-1AB 21-12

SG160SD-1AC 21-12SG160SD-1EA 21-12SG160SD-1EB 21-13SG160SD-1EC 21-13SG160SD-3/4AA 21-12

SG160SD-3/4AB 21-12SG160SD-3/4AC 21-12SG160SD-3/4EA 21-12SG160SD-3/4EB 21-13SG160SD-3/4EC 21-13

SG162-1/2A 21-14SG162-1/2C 21-14SG162D-1/2A 21-15SG162D-1/2C 21-15SI06T-1 18-11

SI06T-1/2 18-11SI06T-11/2 18-11SIN-0010-5-0-P 7-13SIN-0018-5-0-P 7-13SIN-0032-5-0-P 7-13

SIN-0048-5-0-P 7-13SIN-0075-5-0-P 7-13SIN-0110-5-0-P 7-13SIN-0180-5-0-P 7-13SK06T-1/2 18-9, 18-11

SK06T-11/2 18-9, 18-11SK06T-1B 18-9, 18-11SK06TG-1/2 21-9, 21-13SLF15 8-38, 29-3SM06T-1/2 18-9, 18-13, 18-15, 18-21, 18-22

SM06T-11/2 18-9, 18-13, 18-15, 18-21, 18-22SM06T-1B 18-9, 18-13, 18-15, 18-21, 18-22SM110-1/2A1.5 16-2SM110-1/2A2.0 16-2SM110-1/2A2.5 16-2

SM110-1/2A3.0 16-2SM110-1/2A4.0 16-2SM110-1/2A6.0 16-2SM110-1/2AA1.5 16-2SM110-1/2AA2.05 16-2

Page 25: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-24 http://products.ecc.emea.honeywell.com/europe

SM110-1/2AA3.05 16-2SM110-1/2ZA2.5 16-2SM110-1/2ZA3.0 16-2SM110-3/4A1.5 16-2SM110-3/4A2.5 16-2

SM110-3/4A3.0 16-2SM110-3/4A4.0 16-2SM110-3/4ZA2.5 16-2SM110-3/4ZA3.0 16-2SM120-1/2A 16-3

SM120-1/2B 16-3SM120-11/4A 16-3SM120-11/4B 16-3SM120-1A 16-3SM120-1B 16-3

SM120-3/4A 16-3SM120-3/4B 16-3SM150-1/2A 16-4SM150-1/2B 16-4SM150-1/2C 16-4

SM150-1/2F 16-4SM150-1/2ZA 16-4SM150-1/2ZB 16-4SM150-1/2ZC 16-4SM150-1/2ZF 16-4

SM150-3/4A 16-4SM150-3/4B 16-4SM150-3/4C 16-4SM150-3/4F 16-4SM150-3/4ZA 16-4

SM150-3/4ZB 16-4SM150-3/4ZC 16-4SM150-3/4ZF 16-4SM152-1/2AA 21-2SM152-1/2AB 21-2

SM152-1/2AC 21-2SM152-1/2BA 21-3SM152-1/2BC 21-3SM152-11/4AA 21-2SM152-11/4AB 21-2

SM152-11/4AC 21-2SM152-1AA 21-2SM152-1AB 21-2SM152-1AC 21-2SM152-3/4AA 21-2

SM152-3/4AB 21-2SM152-3/4AC 21-2SM180-1/2A10.0 16-5SM180-1/2A2.5 16-5SM180-1/2A3.0 16-5

SM180-1/2A4.0 16-5SM180-1/2A6.0 16-5SM180-1/2A8.0 16-5SM180-1/2ZA10.0 16-5SM180-1/2ZA2.5 16-5

SM180-1/2ZA3.0 16-5SM180-1/2ZA4.0 16-5SM180-1/2ZA6.0 16-5SM180-1/2ZA8.0 16-5SM180-3/4A10.0 16-5

SM180-3/4A2.5 16-5SM180-3/4A3.0 16-5SM180-3/4A4.0 16-5SM180-3/4A6.0 16-5SM180-3/4A8.0 16-5

SM180-3/4ZA10.0 16-5SM180-3/4ZA2.5 16-5SM180-3/4ZA3.0 16-5SM180-3/4ZA4.0 16-5SM180-3/4ZA6.0 16-5

SM180-3/4ZA8.0 16-5SMARTDRIVE-USBC 7-11SRR 3-3SSW2-1M 1-8ST12-4-A 8-30, 8-31, 23-3, 24-3, 24-5

ST12-4-AK 8-30, 8-31, 23-3, 24-3, 24-5ST12-4-G 8-30, 8-31, 23-3, 24-3, 24-5ST12-4-GK 8-30, 8-31, 23-3, 24-3, 24-5ST12-5-A 8-30, 8-31, 23-3, 24-3, 24-5ST12-5-G 8-30, 8-31, 23-3, 24-3, 24-5

ST221 26-2, 26-3, 26-4ST699B1002 11-16ST799A1003 11-16ST9100A1008 11-17ST9100C1006 11-17

ST9100S1007 11-17ST9120C1003 11-19ST9400A1002 11-17ST9400C1000 11-17ST9400S1001 11-17

ST9420C1008 11-19ST9500C1015 11-17ST9520C1005 11-19STA12 8-30, 8-31, 24-3, 24-5STB+TR 9-17

STB+TRF 23-9STB+TW 9-19STB+TWF 23-10STB1 9-13STB1F 23-8

STB2080 9-14, 23-8STB2080F 9-14, 23-9STB70130 9-14, 23-8STB70130F 9-14, 23-9STF21-220 27-3

STF21-75 27-3STF31-220 27-3STF31-75 27-3STG12-100 9-14, 9-16, 23-9, 23-12STG12-100F 9-16, 23-12

STU25 6-11, 6-12STU32 6-11STW+TR 9-18STW+TRF 23-13STW1 9-15

STW1F 23-11STW2080 9-16, 23-12STW2080F 9-16, 23-12STW70130 9-16, 23-12STW70130F 9-16, 23-12

SU53-54 3-4, 3-5SV300-100A 22-12SV300-150A 22-12SV300-200A 22-12SV300-250A 22-12

SV300-300A 22-12SV300-350A 22-12SV300-400A 22-12SV300-450A 22-12SV300-50A 22-12

SV300-65A 22-12SV300-80A 22-12SW2 4-14, 4-16SWF62 8-39, 29-4SWF62L 8-39, 29-4

SWS-12 3-3SYM-BASE01 2-11SYM-BASE02 2-11SYM-BASE03 2-11SYM-DBP00250 2-11

SYM-IF-BACNET 2-12SYM-IF-MODBUS 2-12SYM-IF-OPCCL 2-12SYM-IF-OVN 2-12SYM-IFXL5DIRDIAL 2-12

SYM-NW-MEDE 2-12SYM-NW-OPCSERV 2-12SYM-OP-ALMPAG 2-12SYM-OP-BACSERV 2-12SYM-OP-DTXL 2-12

SYM-OPEASYMB 2-12SYM-OP-FIDELIO 2-12SYM-OP-LNS 2-12SYM-OP-LNSUPG 2-12SYM-STB-UP-STN 2-12

SYM-UPGDR1 2-11SYM-UPGDR2 2-11SYM-UPGDR3 2-11SYM-UPGDRX 2-11SYM-ZZDVD410 2-11

TT100120B3W0 13-2T100120W0 13-2T1001W0GB 13-2

Page 26: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-25

T1002B3W0 13-2T1002B4W0 13-2T1002W0 13-2T1002W0NA 13-2T100M-264F 13-14

T100M-364F 13-14T100MZ-2512 13-14T100MZ-2515 13-14T100R1004 13-15T100R1012 13-15

T100R-AA 13-15, 14-18, 14-19T100R-AB 13-15, 14-18, 14-19T100RS-DA 13-15, 14-18, 14-19T100RS-DB 13-15, 14-18, 14-19T100V-101 13-16

T100V-241 13-16T100VM-101 13-16T100VM-241 13-16T2001 13-5T2001DA 13-5

T2001DAW0 13-5T2001W0 13-5T2021 13-5T2021DA 13-5T2021DAW0 13-5

T2021W0 13-5T3001 13-4T300120 13-4T300120W0 13-4T3001DA 13-4

T3001DAW0 13-4T3001W0 13-4T4021 13-3T4021GB 13-3T4021V1 13-3

T4111 13-3T4111GB 13-3T4221 13-3T4221GB 13-3T4321 13-3

T4321GB 13-3T4360A1009 11-10T4360A1017 11-10T4360A1025 11-10T4360B1007 11-11

T4360B1015 11-11T4360B1031 11-11T4360B1080 11-11T4360B1098 11-11T4360C1021 11-11

T4360C1039 11-11T4360D1003 11-12T4360D1011 11-12T4360E1000 11-11T4360E1018 11-11

T4360F1008 11-11T4NST 9-13, 9-15, 9-20, 23-8, 23-11T4NSTF 9-13, 9-15, 23-8, 23-11T5NST 9-17, 9-18, 9-19, 23-9, 23-10,

23-13

T5NSTF 9-17, 9-18, 9-19, 23-9, 23-10, 23-13

T6001 13-6T600120 13-6T600120DA 13-7

T600120W0 13-6T6001C 13-6T6001DA 13-7T6001DAC 13-7T6001DAW0 13-7

T6001DAW0C 13-7T6001HZ 13-7T6001HZW0 13-7T6001W0 13-6T6001W0C 13-6

T6002 13-6T6002W0 13-6T6101RUB15 13-17T6102 13-17T6102AUB15 13-17

T6102RUB15 13-17T6120A1005 9-21, 23-4T6120B1003 9-21, 23-4T631C1160 9-21T631C1178 9-21

T6360A1004 11-13T6360A1012 11-13T6360B1002 11-13T6360B1010 11-13T6360B1028 11-13

T6360B1036 11-13T6360B1069 11-13T6360B1085 11-13T6360B1093 11-13T6360B1168 11-13

T6360C1000 11-13T6360C1018 11-13T6370A1010 9-3T6371A1019 9-3T6371B1017 9-3

T6371C1015 9-3T6372A1018 9-4T6372B1024 9-4T6372B1032 9-4T6372C1014 9-4

T6373A1017 9-4T6373A1157 9-4T6373B1015 9-4T6373B1064 9-4T6373C1013 9-4

T6374C1004 9-5T6374C1012 9-5T6375B1013 9-5T6375B1021 9-5T6375C1003 9-5

T6375D1001 9-5T6376B1004 9-6T6377B1003 9-6T6377B1011 9-6T6377B1045 9-6

T6377B1151 9-6T6580A1008 9-8T6580A1016 9-8T6590A1000 9-9T6590B1000 9-9

T6631B1005 11-7T6631B1021 11-7T6637B1009 11-6T6637B1017 11-6T6667Z1072 12-5, 12-6

T6812A1000 9-7T7001 13-9T700120 13-9T700120W0 13-9T7001B3 13-9

T7001W0 13-9T7270A2001 1-12T7270A2019 1-12T7270B2009 1-12T7411A1001 8-13

T7411A1019 8-13T7411A1043 8-13T7412A1000 3-6, 8-6, 8-17T7412A1018 8-11T7412A1059 8-11

T7412B1008 8-6, 8-17T7412B1016 8-11T7412B1040 8-11T7412C1006 8-6, 8-17T7412D1004 8-6, 8-17

T7412E1027 8-6, 8-17T7413A1009 8-11T7413A1041 8-11T7413A1058 8-11T7414A1008 8-11

T7414C1004 8-13T7414C1012 3-3, 8-8, 9-9, 12-5T7415A1007 8-12T7415A1015 8-12T7416A1014 8-13

T7416A1022 8-9T7416A1030 8-9T7425A1005 8-7T7425A1013 8-7T7425A1021 8-7

Page 27: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-26 http://products.ecc.emea.honeywell.com/europe

T7425B1011 8-12T7425B1029 8-12T7460A1001 1-13, 8-18T7460B1009 1-13, 8-18T7460C1007 1-13, 8-18

T7460D1005 1-13, 8-18T7460E1002 1-13, 8-18T7460F1000 1-13, 8-18T7460LIMITER 1-13, 8-18T7460LONJACK 1-13, 1-14, 8-18, 8-20

T7470A1009 8-5T750120 13-10T7560A1000 1-14, 8-20T7560A1018 1-14, 8-20T7560A1026 1-14, 8-20

T7560B1008 1-14, 8-20T7560B1016 1-14, 8-20T7560B1024 1-14, 8-20T7560BLINDS 1-14, 8-20T7560C1006 8-15

T8078C1009 1-15, 9-2T8109C1002 1-15, 9-2T8360A1000 11-14T850V24 13-13T9001 13-8

T900120 13-8T900120W0 13-8T9001DA 13-8T9001DAW0 13-8T9001HP 13-8

T9001W0 13-8T9001W0HP 13-8T9002 13-8T9002W0 13-8T950120W0 13-11

T950150W0 13-11TA1000A001 13-2, 13-4, 13-5, 13-7, 13-9,

13-13, 13-14, 13-15, 13-17TA1000A002 13-2, 13-4, 13-5, 13-7, 13-9,

13-13, 13-14, 13-15

TA1000A011 13-13TA1000A022 13-13TA1000B001 13-7, 13-17TA1010DA01 13-2, 13-3, 13-4, 13-5, 13-7,

13-9, 13-10, 13-11, 13-13,

13-15TA1010HZ01 13-2, 13-3, 13-4, 13-5, 13-7,

13-9, 13-10, 13-11, 13-13, 13-15

TA160S 21-7, 21-9, 21-11, 21-13

TA2080A001 13-9, 13-10TA2085A001 13-10TA2085B001 13-10TA3000C001 13-4, 13-5TA3000C002 13-4, 13-5

TA6000A001 13-7TA6900A001 13-2, 13-4, 13-5, 13-7, 13-9,

13-13, 13-15, 13-17TA6900B001 13-13, 13-17TAM022 9-11, 23-6

TAM150 9-11, 23-6TAM490 9-11, 23-6TAM813 9-11, 23-6TBS-SMILE 3-3TBS-smile-1kit 3-3

TC300-100A 22-13TC300-150A 22-13TC300-200A 22-13TC300-250A 22-13TC300-300A 22-13

TC300-350A 22-13TC300-400A 22-13TC300-450A 22-13TC300-50A 22-13TC300-65A 22-13

TC300-80A 22-13TF21 27-3TF22 3-5, 8-5TF31 27-3TFU22 3-5, 8-5

TG510A 3-3TG511A 3-3TH07K 22-18TK295 16-10, 16-12, 20-6, 20-8, 20-9,

20-10, 20-12, 20-13, 20-14,

20-18, 20-19, 20-20TKA295 16-10, 16-12, 20-6, 20-8, 20-9,

20-10, 20-12, 20-13, 20-14, 20-18, 20-19, 20-20

TM200-3/4A 21-18

TM200-3/4B 21-18TM200A-30/60 21-18TM200SOLAR-3/4A 21-19TM200SOLAR-3/4E 21-19TM300-3/4H 21-20

TM300-3/4I 21-20TM300SOLAR-3/4A 21-20TM3400.910 21-21TM3400.912 21-21TM3400.914 21-21

TM3400.916 21-22TM3400.920 21-21TM3400.922 21-21TM3400.924 21-21TM3400.926 21-22

TM3400.930 21-21TM3400.932 21-21TM3400.934 21-21TM3400.936 21-22TM3400.940 21-21

TM3400.942 21-21TM3400.944 21-21TM3400.946 21-22TM3400.950 21-21TM3400.952 21-21

TM3400.954 21-21TM3400.956 21-22TM3400.960 21-21TM3400.962 21-21TM3400.964 21-21

TM3400.966 21-22TM3410.601 21-21TM3410.605 21-21TM3410.606 21-21TM3410.608 21-22

TM3410.801 21-21TM3410.805 21-21TM3410.806 21-21TM3410.808 21-22TM50-1/2E 21-16

TM50-1/2ERV 21-16TM50SOLAR-1/2E 21-17TM50SOLAR-1/2ERV 21-17TPU-11-01 2-4TPU-45-01 2-4

TRM022 9-22, 23-5TRM150 9-22, 23-5TRM40 9-22, 23-5TRMV150 9-22, 23-5TRMV40 9-22, 23-5

TS131-3/4A 16-6TS131-3/4B 16-6TS131K-3/4S 16-6TS131TWG-3/4A 16-6TS131TWG-3/4B 16-6

TST050G12100 23-2TST050G12100-R 23-2TST050G12250 23-2TST050G12250-R 23-2TST200EPT1K 23-2

TST200EPT1K-R 23-2TST200G12100 23-2TST200G12100-R 23-2TST200G12250 23-2TST200G12250-R 23-2

TST400EPT1K 23-2TST400EPT1K-R 23-2TW20A 3-4, 3-5TWP1 9-20TX023 23-7

TX150 23-7TX490 23-7TX813 23-7TXB023 23-7TXB150 23-7

Page 28: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-27

TXB490 23-7TXB813 23-7

UU10 2-13U430B 8-22, 8-23, 8-25, 8-26, 8-27, 8-30,

8-31, 24-3, 24-5, 24-9, 24-11, 24-12,

24-13, 24-14, 24-15, 24-17, 24-19, 24-20, 24-21, 24-22, 24-23, 24-25, 24-26, 24-27, 24-28, 24-29, 24-30,

24-31, 24-32, 25-6U480B 24-32, 25-6

VV135-1/2B 14-18V135-1/2C 14-18V135-11/4B 14-18

V135-11/4C 14-18V135-1B 14-18V135-1C 14-18V135-3/4B 14-18V135-3/4C 14-18

V135A-1/2VE 14-18V135A-11/2VE 14-18V135A-1VE 14-18V136-15B 14-19V136-25B 14-19

V1810X0015 22-17V1810X0020 22-17V1810X0025 22-17V1810X0032 22-17V1810X0040 22-17

V1810Y0015 22-17V1810Y0020 22-17V1810Y0025 22-17V1810Y0032 22-17V1810Y0040 22-17

V1816Y0015 22-17V1816Y0018 22-17V1816Y0020 22-17V1816Y0025 22-17V1816Y0032 22-17

V1816Y0040 22-17V1817Y0015 22-18V1817Y0018 22-18V1817Y0020 22-18V1817Y0025 22-18

V1817Y0032 22-18V1817Y0040 22-18V2000ABB10 13-21V2000ABB15 13-21V2000AFS10 13-31

V2000AFS15 13-31V2000AK410 13-23V2000AK415 13-23V2000AK510 13-23V2000AK515 13-23

V2000ASC15 13-33V2000AUB10 13-25V2000AUB15 13-25V2000AVS10 13-29V2000AVS15 13-29

V2000BBB15 13-21V2000BK415 13-23V2000BK515 13-23V2000BUB15 13-25V2000DBB10 13-20

V2000DBB15 13-20V2000DBB20 13-20V2000DFS10 13-30V2000DFS15 13-30V2000DFS20 13-30

V2000DFV10 13-32V2000DFV15 13-32V2000DK310 13-22V2000DK315 13-22V2000DK410 13-22

V2000DK415 13-22V2000DK510 13-22V2000DK515 13-22V2000DK520 13-22V2000DSC10 13-33

V2000DSC15 13-33V2000DSC20 13-33V2000DSL15 13-27V2000DSL20 13-27V2000DUB10 13-24

V2000DUB15 13-24V2000DUB20 13-24V2000DUB25 13-24V2000DVS10 13-28V2000DVS15 13-28

V2000DVS20 13-28V2000EBB10 13-20V2000EBB15 13-20V2000EBB20 13-20V2000EFS10 13-30

V2000EFS15 13-30V2000EFS20 13-30V2000EFV10 13-32V2000EFV15 13-32V2000EK310 13-22

V2000EK315 13-22V2000EK410 13-22V2000EK415 13-22V2000EK510 13-22V2000EK515 13-22

V2000EK520 13-22V2000ESC10 13-33V2000ESC15 13-33V2000ESC20 13-33V2000ESL15 13-27

V2000ESL20 13-27V2000EUB10 13-24V2000EUB15 13-24V2000EUB20 13-24V2000EUB25 13-24

V2000EVS10 13-28V2000EVS15 13-28V2000EVS20 13-28V2000HBB10 13-21V2000HBB15 13-21

V2000IBB10 13-21V2000IBB15 13-21V2000LBB10 13-21V2000LBB15 13-21V2000LK410 13-23

V2000LK415 13-23V2000LUB10 13-25V2000LUB15 13-25V2000LVS10 13-29V2000LVS15 13-29

V2000RBB10 13-21V2000RBB15 13-21V2000RK410 13-23V2000RK415 13-23V2000RUB10 13-25

V2000RUB15 13-25V2000RVS10 13-29V2000RVS15 13-29V200NCUB15 13-46V200SCUB15 13-46

V2020DBB10 13-20V2020DBB15 13-20V2020DBB20 13-20V2020DFS10 13-30V2020DFS15 13-30

V2020DK410 13-22V2020DK415 13-22V2020DK515 13-22V2020DSL10 13-27V2020DSL15 13-27

V2020DSL20 13-27V2020DUB10 13-25V2020DUB15 13-25V2020DUB20 13-25V2020DVS10 13-28

V2020DVS15 13-28V2020DVS20 13-28V2020EBB10 13-20V2020EBB15 13-20V2020EBB20 13-20

Page 29: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-28 http://products.ecc.emea.honeywell.com/europe

V2020EFS10 13-30V2020EFS15 13-30V2020EK410 13-22V2020EK415 13-22V2020EK515 13-22

V2020ESL10 13-27V2020ESL15 13-27V2020ESL20 13-27V2020EUB10 13-25V2020EUB15 13-25

V2020EUB20 13-25V2020EVS10 13-28V2020EVS15 13-28V2020EVS20 13-28V2047EUB08 13-26

V2047EUB10 13-26V2047EUB15 13-26V2050DH015 13-34V2050DH020 13-34V2050DH025 13-34

V2050EH015 13-34V2050EH020 13-34V2050EH025 13-34V2050HH015 13-34V2050HH020 13-34

V2060DK515 13-23V2060DUB15 13-24V2060EK515 13-23V2060LK515 13-23V2060RK515 13-23

V2081DSL15 13-18V2081ESL15 13-18V2081LSL15 13-18V2081RSL15 13-18V2082DSL15 13-18

V2082ESL15 13-18V2082LSL15 13-18V2082RSL15 13-18V2400D0010 13-42V2400D0015 13-42

V2400D0020 13-42V2400E0010 13-42V2400E0015 13-42V2400E0020 13-42V2406D0015 13-42

V2420D0010 13-43V2420D0015 13-43, 13-49V2420D0020 13-43V2420E0010 13-43V2420E0015 13-43, 13-49

V2420E0020 13-43V2426D0015 13-43V2461DX20 13-47V2461DY15 13-47V2461EX20 13-47

V2461EY15 13-47V2465DX015 13-49V2465DY015 13-49V2465EX015 13-49V2465EY015 13-49

V2466DX015 13-49V2466EX015 13-49V2471DX20 13-47V2471DY15 13-47V2471EX20 13-47

V2471EY15 13-47V2476DX020 13-48V2476DY015 13-48V2476EX020 13-48V2476EY015 13-48

V2481D0015 13-40V2481E0015 13-40V2481L0015 13-40V2481R0015 13-40V2482D0015 13-40

V2482E0015 13-40V2482L0015 13-40V2482R0015 13-40V2495DX020 13-50V2495DY015 13-50

V2495EX020A 13-50V2495EY015A 13-50V2496DX020 13-51V2496DY015 13-51V2496EX020A 13-51

V2496EY015A 13-51V2605D0010 13-37V2605D0015 13-37V2605D0020 13-37V2605E0010 13-37

V2605E0015 13-37V2605E0020 13-37V2652D0010 13-38V2652D0015 13-38V2652D0020 13-38

V2652E0010 13-38V2652E0015 13-38V2652E0020 13-38V2881DSL15 13-45V2881LSL15 13-45

V2881RSL15 13-45V2882DSL15 13-45V2882LSL15 13-45V2882RSL15 13-45V300DBB10 13-39

V300DBB15 13-39V300EBB10 13-39V300EBB15 13-39V305DSLGB10 13-35V305DSLGB15 13-35

V305ESLGB10 13-35V305ESLGB15 13-35V310DBB10 13-39V310DBB15 13-39V310EBB10 13-39

V310EBB15 13-39V310RBB15 13-39V320DSLGB10 13-36V320DSLGB15 13-36V320ESLGB10 13-36

V320ESLGB15 13-36V320RSLGB15 13-36V330D010 13-44V330D015 13-44V330E010 13-44

V330E015 13-44V340D010 13-44V340D015 13-44V340E010 13-44V340E015 13-44

V4043C1255 15-2V4043C1263 15-2V4043C1271 15-2V4044C1452 15-3V4044C1460 15-3

V4044C1478 15-3V4044F1000 15-3V4044F1034 15-3V4119YX015 22-19V4119YX020 22-19

V4120FF015 22-19V4120FF020 22-19V4120FF025 22-19V4120FF032 22-19V4120FF040 22-19

V4120FF050 22-19V4120FF065 22-19V4120FF080 22-19V4120FF100 22-19V4120KK015 22-19

V4120KK020 22-19V4120KK025 22-19V4120KK032 22-19V4120KK040 22-19V4120KK050 22-19

V4120XX015 22-19V4120XX020 22-19V4120XX025 22-19V4120XX032 22-19V4120XX040 22-19

V4120XX050 22-19V4120XX065 22-19V4120XX080 22-19V4120YX015 22-19V4120YX020 22-19

Page 30: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-29

V4120YX025 22-19V4120YX032 22-19V4120YX040 22-19V4120YX050 22-19V4120YY015 22-18

V4120YY020 22-18V4120YY025 22-18V4120YY032 22-18V4120YY040 22-18V4120YY050 22-18

V5000X0010 14-11V5000X0015 14-11V5000X0020 14-11V5000X0025 14-11V5000X0032 14-11

V5000X0040 14-11V5000X0050 14-11V5000Y0010 14-10V5000Y0015 14-10V5000Y0020 14-10

V5000Y0025 14-10V5000Y0032 14-10V5000Y0040 14-10V5000Y0050 14-10V5000Y0065 14-10

V5000Y0080 14-10V5001PY1015 14-4V5001PY1020 14-4V5001PY1025 14-4V5001PY1032 14-4

V5001PY1040 14-4V5001PY1050 14-4V5001PY2015 14-5V5001PY2020 14-5V5001PY2025 14-5

V5001PY2032 14-5V5001PY2040 14-5V5001PY2050 14-5V5001PZ1015 14-5V5001PZ1020 14-5

V5001PZ1025 14-5V5001PZ1032 14-5V5001PZ1040 14-5V5001PZ1050 14-5V5001SY2015 14-2, 14-5

V5001SY2020 14-2, 14-5V5001SY2025 14-2, 14-5V5001SY2032 14-2, 14-5V5001SY2040 14-2, 14-5V5001SY2050 14-2, 14-5

V5001SZ1015 14-3V5001SZ1020 14-3V5001SZ1025 14-3V5001SZ1032 14-3V5001SZ1040 14-3

V5001SZ1050 14-3V5003FY10150412 14-7V5003FY10150609 14-7V5003FY10150825 14-7V5003FY10200412 14-7

V5003FY10200609 14-7V5003FY10200825 14-7V5003FY10250412 14-7V5003FY10250609 14-7V5003FY10250825 14-7

V5003FY10265020 14-7V5003FY10325020 14-7V5003FY10401610 14-7V5003FY10501610 14-7V5003FY20150615 14-7

V5003FY20150896 14-7V5003FY20151270 14-7V5003FY20200615 14-7V5003FY20200896 14-7V5003FY20201270 14-7

V5003FY20250615 14-7V5003FY20250896 14-7V5003FY20251270 14-7V5003FZ10150412 14-7V5003FZ10150609 14-7

V5003FZ10150825 14-7V5003FZ10325020 14-7V5003FZ10501610 14-7V5003FZ20150615 14-7V5003FZ20150896 14-7

V5003FZ20151270 14-7V5003TY1015 14-8V5003TY1020 14-8V5003TY1025 14-8V5003TY2015 14-8

V5003TY2020 14-8V5003TY2025 14-8V5003TZ1015 14-9V5003TZ2015 14-9V5010X0010 14-13

V5010X0015 14-13V5010X0020 14-13V5010X0025 14-13V5010X0032 14-13V5010X0040 14-13

V5010X0050 14-13V5010Y0010 14-12V5010Y0015 14-12V5010Y0020 14-12V5010Y0025 14-12

V5010Y0032 14-12V5010Y0040 14-12V5010Y0050 14-12V5010Y0065 14-12V5010Y0080 14-12

V5011R1000 5-14V5011R1018 5-14V5011R1026 5-14V5011R1034 5-14V5011R1042 5-14

V5011R1059 5-14V5011R1067 5-14V5011R1075 5-14V5011R1083 5-14V5011R1091 5-14

V5011S1005 5-14V5011S1013 5-14V5011S1021 5-14V5011S1039 5-14V5011S1047 5-14

V5011S1054 5-14V5011S1062 5-14V5011S1070 5-14V5011S1088 5-14V5011S1096 5-14

V5012C0103 14-13, 14-14V5012C0306 14-13, 14-14V5013E1063 5-42V5013E1071 5-42V5013E1089 5-42

V5013E1097 5-42V5013E1105 5-42V5013E1113 5-42V5013E1121 5-42V5013R1032 5-43

V5013R1040 5-43V5013R1057 5-43V5013R1065 5-43V5013R1073 5-43V5013R1081 5-43

V5013R1099 5-43V5015A1151 5-44V5015A1169 5-44V5015A1177 5-44V5016A1010 5-18

V5016A1028 5-18V5016A1036 5-18V5016A1044 5-18V5016A1051 5-18V5016A1069 5-18

V5016A1077 5-18V5016A1085 5-18V5016A1093 5-18V5016A1101 5-18V5016A1119 5-18

V5016A1127 5-18V5016A1135 5-18V5016A1143 5-18V5016A1150 5-18V5016A1168 5-18

Page 31: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-30 http://products.ecc.emea.honeywell.com/europe

V5025A1019 5-20V5025A1027 5-20V5025A1035 5-20V5025A1043 5-20V5025A1050 5-20

V5025A1068 5-20V5025A1076 5-20V5025A1084 5-20V5025A1092 5-20V5025A1100 5-20

V5025A1118 5-20V5025A1126 5-20V5025A1134 5-20V5025A1142 5-20V5025A1159 5-20

V5025A1167 5-20V5049A1425 5-22V5049A1433 5-22V5049A1441 5-22V5049A1458 5-22

V5049A1508 5-22V5049A1565 5-22V5049A1573 5-22V5049A1581 5-22V5049A1599 5-22

V5049A1607 5-22V5049A1615 5-22V5049A1623 5-22V5049A2027 5-22V5049A2035 5-22

V5049A2043 5-22V5050A1090 5-46V5050A1108 5-46V5050A1116 5-46V5050A1124 5-48

V5050A1132 5-48V5050A1140 5-48V5050A1157 5-48V5050A1165 5-48V5050A1173 5-48

V5050A1181 5-48V5050A1199 5-48V5050A1207 5-48V5050A1215 5-48V5050B1064 5-46

V5050B1072 5-46V5050B1080 5-46V5050B1155 5-48V5078B1005 5-41V5078B1013 5-41

V5078B1021 5-41V5078B1039 5-41V5078B1047 5-41V5078B1054 5-41V5100X0010 14-17

V5100X0015 14-17V5100X0020 14-17V5100X0025 14-17V5100X0032 14-17V5100X0040 14-17

V5100Y0010 14-17V5100Y0015 14-17V5100Y0020 14-17V5100Y0025 14-17V5100Y0032 14-17

V5100Y0040 14-17V5328A1005 5-16V5328A1013 5-16V5328A1021 5-16V5328A1039 5-16

V5328A1047 5-16V5328A1054 5-16V5328A1062 5-16V5328A1070 5-16V5328A1088 5-16

V5328A1096 5-16V5328A1104 5-16V5328A1112 5-16V5328A1138 5-16V5328A1146 5-16

V5328A1153 5-16V5328A1195 5-16V5328A1203 5-16V5328A1211 5-16V5329A1004 5-46

V5329A1012 5-46V5329A1020 5-46V5329A1038 5-46V5329A1046 5-46V5329A1053 5-46

V5329A1061 5-46V5329A1079 5-46V5329A1087 5-46V5329C1000 5-44V5329C1018 5-44

V5329C1026 5-44V5329C1034 5-44V5329C1042 5-44V5329C1059 5-44V5329C1067 5-44

V5329C1075 5-44V5329C1083 5-44V5421B1009 6-2V5421B1017 6-2V5421B1025 6-2

V5421B1033 6-2V5421B1041 6-2V5421B1058 6-2V5421B1066 6-2V5421B1074 6-2

V5421B1082 6-2V5421B1090 6-2V5422E1001 6-3V5422E1019 6-3V5422L1006 6-3

V5422L1014 6-3V5433A1015 6-6V5433A1023 6-6V5433A1031 6-6V5433A1049 6-6

V5433A1056 6-6V5433A1064 6-6V5433A1072 6-6V5433G1004 6-7V5433G1012 6-7

V5433G1020 6-7V5433G1038 6-7V5433G1046 6-7V5433G1053 6-7V5433G1061 6-7

V5442A1022 6-9V5442A1030 6-9V5442A1048 6-9V5442A1055 6-9V5442G1003 6-10

V5442G1011 6-10V5442G1029 6-10V5442G1037 6-10V5822A1006 5-6V5822A1014 5-6

V5822A1022 5-6V5822A1030 5-6V5822A1048 5-6V5822A1055 5-6V5822A1063 5-6

V5822A1071 5-6V5822A4000 5-6V5822A4018 5-6V5823A2003 5-32V5823A2011 5-32

V5823A2029 5-32V5823A2037 5-32V5823A2045 5-32V5823A2052 5-32V5823A2060 5-32

V5823A2151 5-32V5823A2169 5-32V5823A4009 5-32V5823A4017 5-32V5823C2009 5-34

V5823C2017 5-34V5823C2025 5-34V5823C2033 5-34V5823C2041 5-34V5823C2058 5-34

Page 32: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-31

V5823C2066 5-34V5823C2157 5-34V5823C2165 5-34V5823C4005 5-34V5823C4013 5-34

V5825B1001 5-12V5825B1019 5-12V5825B1027 5-12V5825B1035 5-12V5825B1043 5-12

V5825B1050 5-12V5825B1068 5-12V5825B1076 5-12V5825B1084 5-12V5832A1004 5-8

V5832A1012 5-8V5832A1020 5-8V5832A1038 5-8V5832A1046 5-8V5832A1053 5-8

V5832A1061 5-8V5832A1079 5-8V5832A4008 5-8V5832A4016 5-8V5832B2075 5-10

V5832B2083 5-10V5832B2091 5-10V5832B2109 5-10V5832B2117 5-10V5833A1003 5-36

V5833A1011 5-36V5833A1029 5-36V5833A1037 5-36V5833A1045 5-36V5833A1052 5-36

V5833A1060 5-36V5833A2076 5-40V5833A2084 5-40V5833A2092 5-40V5833A2100 5-40

V5833A2118 5-40V5833A3009 5-36V5833A3017 5-36V5833A4007 5-36V5833A4015 5-36

V5833C1009 5-38V5833C1017 5-38V5833C1025 5-38V5833C1033 5-38V5833C1041 5-38

V5833C1058 5-38V5833C1066 5-38V5833C1140 5-38V5833C1152 5-38V5833C4003 5-38

V5833C4011 5-38V9406DX015 14-20VA2100B001 13-37VA2200C001 13-19, 13-45VA2200C002 13-19, 13-45

VA2200D001 13-21, 13-23, 13-25, 13-26, 13-27, 13-29, 13-31, 13-32, 13-33, 13-34

VA2201D012 13-19, 13-41, 13-45VA2201D014 13-19, 13-41, 13-45VA2201D015 13-19, 13-41, 13-45

VA2201D016 13-19, 13-41, 13-45VA2201D018 13-19, 13-41, 13-45VA2201D020 13-19, 13-41, 13-45VA2201E012 13-19, 13-41, 13-45VA2201E014 13-19, 13-41, 13-45

VA2201E015 13-19, 13-41, 13-45VA2201E016 13-19, 13-41, 13-45VA2201E018 13-19, 13-41, 13-45VA2201E020 13-19, 13-41, 13-45VA2202A010 13-21, 13-23, 13-25, 13-27, 13-29,

13-31, 13-32, 13-33, 13-35, 13-36, 13-37, 13-38, 13-39, 13-42, 13-43

VA2202A015 13-21, 13-23, 13-25, 13-26, 13-27, 13-29, 13-31, 13-32, 13-33, 13-34, 13-35, 13-36, 13-37, 13-38, 13-39,

13-42, 13-43VA2202A020 13-21, 13-23, 13-25, 13-27, 13-29,

13-33, 13-34, 13-37, 13-38, 13-42, 13-43

VA2400A002 22-18

VA2400B002 22-18VA2500A001 14-13VA2500CU04 14-5VA2501A010 14-11, 14-13VA2501A032 14-11, 14-13

VA2502A002 14-14VA2503A001 14-14VA2504A001 14-14VA2510C015 14-11, 14-13, 14-15, 22-18, 22-20VA2510C020 14-11, 14-13, 14-15, 22-18, 22-20

VA2510C025 14-11, 14-13, 14-15, 22-18, 22-20VA2510C032 14-11, 14-13, 14-15, 22-18, 22-20VA2510C040 14-11, 14-13, 14-15, 22-18, 22-20VA2510C050 14-11, 14-13, 14-15, 22-18, 22-20VA2510D015 14-3, 14-5

VA2510D020 14-3, 14-5VA2510D025 14-3, 14-5VA2510D032 14-3, 14-5VA2510D040 14-3, 14-5VA2510D050 14-3, 14-5

VA2601A008 14-7, 14-9VA3300A001 13-42, 13-43, 13-49, 14-20VA3300B001 13-47VA3301A001 14-20VA3400A001 22-18

VA3400C001 22-18VA3401A008 14-3, 14-5, 22-20VA3401A010 22-20VA3500A001 14-11, 14-13, 14-17VA3502A001 14-11

VA3600C001 14-7, 14-9VA4250A008 22-20VA4250A010 22-20VA5003ZA001 14-7, 14-9VA5003ZA003 14-7, 14-9

VA5003ZA004 14-7VA5003ZA005 14-7VA5090A010 13-21, 13-23, 13-25, 13-27, 13-29,

13-31, 13-32, 13-33, 13-35, 13-36, 13-37, 13-38, 13-39, 13-42, 13-43,

14-16VA5090A015 13-21, 13-23, 13-25, 13-26, 13-27,

13-29, 13-31, 13-32, 13-33, 13-34,13-35, 13-36, 13-37, 13-38, 13-39,

13-42, 13-43, 14-16

VA5090A020 13-21, 13-23, 13-25, 13-27, 13-29,13-33, 13-34, 13-37, 13-38, 13-42,

13-43, 14-16VA5090A025 14-16VA5090A032 14-16

VA5090A040 14-16VA5090A050 14-16VA5096A015 13-51VA5096B015 13-51VA5500A010 14-16

VA5500A015 14-16VA5500A020 14-16VA5500A025 14-16VA5500A032 14-16VA5500A040 14-16

VA5500A050 14-16VA5530A010 14-16VA5530A015 14-16VA5530A020 14-16VA5530A025 14-16

VA5530A032 14-16VA5530A040 14-16VA5530A050 14-16VA5540A010 14-16VA5540A015 14-16

VA5540A020 14-16VA5540A025 14-16VA5540A032 14-16VA5540A040 14-16VA5540A050 14-16

VA650A1010 14-15VA650A1012 14-15VA650A1510 14-15VA650A1512 14-15VA650A1514 14-15

Page 33: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-32 http://products.ecc.emea.honeywell.com/europe

VA650A1515 14-15VA650A1516 14-15VA650A2018 14-15VA650A2022 14-15VA651A1012 14-15

VA651A1512 14-15VA651A1515 14-15VA651A1516 14-15VA651A2018 14-15VA7200A010 13-50, 13-51

VA7200A012 13-50, 13-51VA7200A014 13-50, 13-51VA7200A015 13-50, 13-51VA7200A016 13-50, 13-51VA7200A018 13-50, 13-51

VA720C1200 13-19, 13-41, 13-46VA720C1400 13-19, 13-41, 13-46VA720C1500 13-19, 13-41, 13-46VA720C1600 13-19, 13-41, 13-46VA721C1211 13-19, 13-41, 13-46

VA721C1420 13-19, 13-41, 13-46VA721C1615 13-19, 13-41, 13-46VA721C1620 13-19, 13-41, 13-46VA721C1820 13-19, 13-41, 13-46VA722C1420 13-19, 13-41, 13-46

VA722C1620 13-19, 13-41, 13-46VA722C1820 13-19, 13-41, 13-46VA722C2020 13-19, 13-41, 13-46VA7403A015 17-2, 17-3, 17-5, 17-9, 17-12VA7403A018 17-2, 17-3, 17-5, 17-9, 17-12

VA7403A020 17-2, 17-3, 17-5, 17-9, 17-12VA7403A025 17-5, 17-9, 17-12VA7404A015 17-2, 17-3, 17-5, 17-9, 17-12VA7404A018 17-2, 17-3, 17-5, 17-9, 17-12VA7404A020 17-2, 17-3, 17-5, 17-9, 17-12

VA7404A025 17-5, 17-9, 17-12VA7405A015 17-2, 17-5, 17-10, 17-12VA7405A018 17-10VA7405A020 17-2, 17-5, 17-10, 17-12VA7405A025 17-5, 17-10, 17-12

VA8200A001 13-18, 13-21, 13-23, 13-25, 13-26, 13-27, 13-29, 13-31, 13-32, 13-33, 13-34, 13-35, 13-36, 13-37, 13-38,

13-39, 13-46VA8201FV01 13-32

VA8201FV02 13-29, 13-31, 13-32VA8201FV03 13-29, 13-31VA8201M301 13-37VA8201SC01 13-33VA8201SC02 13-33

VA8204A001 13-33VA8210A001 13-2, 13-4, 13-5, 13-7, 13-9, 13-10,

13-13, 13-14, 13-15, 13-21, 13-23, 13-25, 13-27, 13-32, 13-33, 13-34

VA8300A001 13-42, 13-43, 13-49, 14-20

VC2010ZZ00 15-3VC4012ZZ00 15-3VC6012ZZ00 15-3VC8010ZZ00 15-3VCM095 24-13

VCM101 24-13VCM301 24-13VCM4156 24-13VCMV095 24-13VCMV101 24-13

VCMV301 24-13VCO2 6-2VCU-SET 6-2VCZAP1000 15-4VCZAQ1000 15-4

VCZMG6000 15-4VCZMH6000 15-4VCZMP6000 15-4VCZMQ6000 15-4VCZZ1000 15-4

VCZZ6000 15-4VE300-1/2A 16-11, 16-19VF04-1/2E 16-8VF06-1/2A 16-7VF06-1/2B 16-7

VF10A 8-7VF10T 8-7VF20A 3-3, 3-6, 8-7VF20L 3-3, 8-7VF20LN 8-7

VF20NT 8-7VF20T 3-3, 8-7VFHT 8-8, 8-11, 8-12VFL 8-11VFLN 8-11

VFNT 8-8, 8-11, 8-12VKD3 24-32, 25-6VKD5 24-32, 25-6VM242A0101 14-3, 14-5, 14-7, 14-9, 14-11,

14-20

VMP10-90 4-12VMS2 4-12VMU1 4-12VNM111 24-13VNM301 24-13

VNMV111 24-13VNMV301 24-13VNS111-201 24-14VNS111-203 24-14VNS301-201 24-14

VNS301-203 24-14VR170-1/2A 22-16VR170-11/2A 22-16VR170-11/4A 22-16VR170-1A 22-16

VR170-21/2A 22-16VR170-2A 22-16VR170-3/4A 22-16VR300-100A 22-14VR300-150A 22-14

VR300-200A 22-14VR300-250A 22-14VR300-300A 22-14VR300-350A 22-14VR300-400A 22-14

VR300-450A 22-14VR300-50A 22-14VR300-65A 22-14VR300-80A 22-14VS1200BB01 13-21, 13-39

VS1200FS01 13-31VS1200FV01 13-32VS1200H020 13-34VS1200K301 13-23VS1200K401 13-23

VS1200K501 13-23VS1200M301 13-37VS1200SC01 13-33VS1200SL01 13-27VS1200SLGB01 13-18, 13-35, 13-36, 13-46

VS1200UB01 13-25VS1200UB02 13-26VS1200VS01 13-29VS1300VF02 13-42, 13-43VS1401A065 22-20

VS1401A080 22-20VS1401B015 22-20VS1401B020 22-20VS1401B025 22-20VS1401B032 22-20

VS1401B040 22-20VS1401B050 22-20VS1501S015 14-17VS1501S025 14-17VS1501S040 14-17

VS2200A001 13-21, 13-23, 13-25, 13-34VS2200B001 13-32VS2200C001 13-33VS2400B050 22-20VS2400B080 22-20

VS2400B120 22-20VS2500KDP1 14-14VS2600C001 14-3, 14-5VS3295A015 13-50VS3296A015 13-51

VS3301A001 13-42VS3301C001 13-43VS3302A001 13-42, 13-43VS4200MI03 13-37VS5500A004 14-5, 14-14

Page 34: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-33

VS5500A008 14-14VS5501A008 14-3, 14-5, 14-14VSMC-215-0.16 5-2VSMC-215-0.25 5-2VSMC-215-0.4 5-2

VSMC-215-0.63 5-2VSMC-215-1.0 5-2VSMC-215-1.6 5-2VSMC-215-2.5 5-2VSMC-220-2.5 5-2

VSMC-220-2.5E 5-2VSMC-220-4.0 5-2VSMC-220-4.0E 5-2VSMC-225-6.3P 5-2VSMC-225-8.0P 5-2

VSMC-315-0.25 5-24VSMC-315-0.4 5-24VSMC-315-0.63 5-24VSMC-315-1.0 5-24VSMC-315-1.6 5-24

VSMC-315-2.5 5-24VSMC-320-2.5 5-24VSMC-320-2.5E 5-24VSMC-320-4.0 5-24VSMC-320-4.0E 5-24

VSMC-325-6.3P 5-24VSMC-325-8.0P 5-24VSMC-415-0.25 5-28VSMC-415-0.4 5-28VSMC-415-0.63 5-28

VSMC-415-1.0 5-28VSMC-415-1.6 5-28VSMC-415-2.5 5-28VSMC-420-2.5 5-28VSMC-420-2.5E 5-28

VSMC-420-4.0 5-28VSMC-420-4.0E 5-28VSMC-425-6.3P 5-28VSMC-425-8.0P 5-28VSMF-215-0.16 5-4

VSMF-215-0.25 5-4VSMF-215-0.4 5-4VSMF-215-0.63 5-4VSMF-215-1.0 5-4VSMF-215-1.6 5-4

VSMF-215-2.5 5-4VSMF-220-2.5 5-4VSMF-220-2.5E 5-4VSMF-220-4.0 5-4VSMF-220-4.0E 5-4

VSMF-225-6.3P 5-4VSMF-225-8.0P 5-4VSMF-315-0.25 5-26VSMF-315-0.4 5-26VSMF-315-0.63 5-26

VSMF-315-1.0 5-26VSMF-315-1.6 5-26VSMF-315-2.5 5-26VSMF-320-2.5 5-26VSMF-320-2.5E 5-26

VSMF-320-4.0 5-26VSMF-320-4.0E 5-26VSMF-325-6.3P 5-26VSMF-325-8.0P 5-26VSMF-415-0.25 5-30

VSMF-415-0.4 5-30VSMF-415-0.63 5-30VSMF-415-1.0 5-30VSMF-415-1.6 5-30VSMF-415-2.5 5-30

VSMF-420-2.5 5-30VSMF-420-2.5E 5-30VSMF-420-4.0 5-30VSMF-420-4.0E 5-30VSMF-425-6.3P 5-30

VSMF-425-8.0P 5-30VSOC-215-1.0 5-2VSOC-215-1.0S 5-2VSOC-215-1.6 5-2VSOC-215-1.6S 5-2

VSOC-215-2.5 5-2VSOC-215-2.5S 5-2VSOC-220-2.5 5-2VSOC-220-2.5S 5-2VSOC-220-4.0 5-2

VSOC-220-4.0S 5-2VSOC-225-4.0P 5-2VSOC-225-5.5P 5-2VSOC-315-1.0 5-24VSOC-315-1.0S 5-24

VSOC-315-1.6 5-24VSOC-315-1.6S 5-24VSOC-315-2.5 5-24VSOC-315-2.5S 5-24VSOC-320-2.5 5-24

VSOC-320-2.5S 5-24VSOC-320-4.0 5-24VSOC-320-4.0S 5-24VSOC-325-4.0P 5-24VSOC-325-5.5P 5-24

VSOC-415-1.0 5-28VSOC-415-1.0S 5-28VSOC-415-1.6 5-28VSOC-415-1.6S 5-28VSOC-415-2.5 5-28

VSOC-415-2.5S 5-28VSOC-420-2.5 5-28VSOC-420-2.5S 5-28VSOC-420-4.0 5-28VSOC-420-4.0S 5-28

VSOC-425-4.0P 5-28VSOC-425-5.5P 5-28VSOF-215-1.0 5-4VSOF-215-1.0S 5-4VSOF-215-1.6 5-4

VSOF-215-1.6S 5-4VSOF-215-2.5 5-4VSOF-215-2.5S 5-4VSOF-220-2.5 5-4VSOF-220-2.5S 5-4

VSOF-220-4.0 5-4VSOF-220-4.0S 5-4VSOF-225-4.0P 5-4VSOF-225-5.5P 5-4VSOF-315-1.0 5-26

VSOF-315-1.0S 5-26VSOF-315-1.6 5-26VSOF-315-1.6S 5-26VSOF-315-2.5 5-26VSOF-315-2.5S 5-26

VSOF-320-2.5 5-26VSOF-320-2.5S 5-26VSOF-320-4.0 5-26VSOF-320-4.0S 5-26VSOF-325-4.0P 5-26

VSOF-325-5.5P 5-26VSOF-415-1.0 5-30VSOF-415-1.0S 5-30VSOF-415-1.6 5-30VSOF-415-1.6S 5-30

VSOF-415-2.5 5-30VSOF-415-2.5S 5-30VSOF-420-2.5 5-30VSOF-420-2.5S 5-30VSOF-420-4.0 5-30

VSOF-420-4.0S 5-30VSOF-425-4.0P 5-30VSOF-425-5.5P 5-30VST06-1/2A 16-7, 16-8, 18-9, 18-13, 18-15,

19-3, 19-11, 19-38, 21-7, 21-9,

21-11, 21-13VST06-1/2B 18-9, 18-13, 18-15, 19-4, 19-11,

19-38, 21-7, 21-9, 21-11, 21-13VST06-11/2A 18-9, 18-13, 18-15, 19-3, 19-38VST06-11/2B 18-9, 18-13, 18-15, 19-4, 19-38

VST06-11/4A 18-9, 18-13, 18-15, 19-3, 19-7, 19-31, 19-38

VST06-11/4B 18-9, 18-13, 18-15, 19-4, 19-7, 19-31, 19-38

VST06-1A 18-9, 18-13, 18-15, 19-3, 19-7,

19-11, 19-31, 19-38, 21-11, 21-13VST06-1B 18-9, 18-13, 18-15, 19-4, 19-7,

19-11, 19-31, 19-38, 21-11, 21-13VST06-2A 18-9, 18-13, 18-15, 19-3, 19-38VST06-2B 18-9, 18-13, 18-15, 19-4, 19-38

Page 35: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

9

10

11

12

13

14

Index of products

Type Page Type Page Type Page

0-34 http://products.ecc.emea.honeywell.com/europe

VST06-3/4A 18-9, 18-13, 18-15, 19-3, 19-7, 19-11, 19-31, 19-38, 21-7, 21-9,

21-11, 21-13VST06-3/4B 16-14, 18-9, 18-13, 18-15, 19-4,

19-7, 19-11, 19-31, 19-38, 21-7, 21-9,

21-11, 21-13VST06I-1/2A 18-11VST06I-1/2B 18-11VST06I-11/2A 18-11VST06I-11/2B 18-11

VST06I-11/4A 18-11VST06I-11/4B 18-11VST06I-1A 18-11VST06I-1B 18-11VST06I-2A 18-11

VST06I-2B 18-11VST06I-3/4A 18-11VST06I-3/4B 18-11VSTM-1/2A 21-11, 21-13VSTM-1A 21-11, 21-13

VSTM-3/4A 21-11, 21-13VV300-100A 22-15VV300-150A 22-15VV300-200A 22-15VV300-250A 22-15

VV300-300A 22-15VV300-350A 22-15VV300-400A 22-15VV300-450A 22-15VV300-50A 22-15

VV300-65A 22-15VV300-80A 22-15

WW6560C1005 3-6W7070A2000 1-12W7704D1008 1-2

W7704D1016 1-2W7750B2011/U 1-9W7750C2001 1-9W7751D2016/U 1-7W7751F2011/U 1-7

W7751H3007 1-8W7752D2007 1-4W7754K1001 1-5W7754P1000 1-5W7754Q1008 1-5

W7754R4431 1-5W7754S2230 1-5W7754V1230 1-5W7762B1019 1-6W7763C1024 1-3

W7763C1032 1-3W7763D1030 1-3W7763E1003 1-3WB10707/U 1-11WBA298-100 20-18, 20-19

WBA298-150 20-18, 20-19WLP1 9-11, 9-22, 23-5, 23-6, 23-7,

23-14, 23-15, 23-16WMSPS-1 1-13, 1-14, 8-19, 8-20WMSPS-10 1-13, 8-19

WMSPS-11 1-13, 8-19WMSPS-2 1-13, 1-14, 8-2, 8-3, 8-4, 8-19,

8-20WMSPS-3 1-13, 1-14, 8-19, 8-20WMSPS-4 1-13, 1-14, 8-19, 8-20

WMSPS-5 1-14, 8-20WMSPS-6 1-14, 8-20WMSPS-8 1-13, 8-19WMSPS-9 1-13, 8-19WS195 20-6

WS295STN 20-12, 20-13WS300NK 16-10, 16-12WT100V 13-16WTU25 6-11, 6-12WTU32 6-11

WV108 5-6, 5-8, 5-32, 5-34, 5-36, 5-38

WV108B 5-6, 5-8, 5-32, 5-34, 5-36, 5-38

WZ300 16-12, 16-19

XX121-AA 16-16XAL10 2-4, 2-10, 2-13XAL-COV-L 1-5, 1-10

XAL-TERM 1-5, 1-12, 2-4, 2-7, 2-8, 2-10, 2-13

XD50B-FCL 2-7XL50-ACC3 2-7XS812 2-4, 2-10, 2-13

XS812RO 2-4, 2-10, 2-13XS814 2-4, 2-10, 2-13XS815 2-4, 2-10, 2-13XS816 2-4, 2-10, 2-13XS821-22 2-3, 2-10, 2-12

XS823 2-3, 2-10, 2-12XS824-25 2-3, 2-10, 2-12XS830 2-4, 2-10XS831 2-4, 2-10XSU821-22 2-3, 2-10

XSU823 2-3, 2-10XSU824-25 2-3, 2-10XW582 2-14XW585 2-7, 2-8, 2-15XW586 2-7, 2-10

XW882 2-10, 2-14XW884 2-10XW885 2-4, 2-10, 2-15

YY6630D1007 12-7Y9120H2009 11-19Y9120W1000 11-19

Y9420H1008 11-19Y9420S2005 11-19Y9520Z1007 11-19

ZZ11AS-1/2A 19-16Z11AS-1/2B 19-16Z11AS-1A 19-16, 19-19

Z11AS-1B 19-16, 19-19Z11S-A 19-3, 19-7, 19-9, 19-15, 19-17,

19-25, 19-31, 19-35, 19-38Z11S-B 19-3, 19-7, 19-9, 19-15, 19-17,

19-25, 19-31, 19-35, 19-38

Z121-1/2 16-16Z121-3/8 16-16Z171T-1/2A 22-16Z171T-11/4A 22-16Z74A-A 19-40

Z74S-A 19-17, 19-27, 19-41Z74S-AN 19-5, 19-8, 19-29, 19-33, 19-41ZA76C 19-31ZA76C-11/4 19-9, 19-35ZFV162-50 24-32, 25-6

ZFV162-50PTFE 24-32, 25-6ZFV184-50 24-32, 25-6ZFV184-50PTFE 24-32, 25-6ZFV184-80 24-32, 25-6ZFV184-80PTFE 24-32, 25-6

ZFV185-50 24-32, 25-6ZFV185-50PTFE 24-32, 25-6ZFV185-80 24-32, 25-6ZFV185-80PTFE 24-32, 25-6ZFV749 - V191 24-32, 25-6

ZFV749 24-32, 25-6ZG215N 3-5ZG215VN 3-5ZG252N 3-4ZN170-1/2A 22-16

ZN170-11/2A 22-16ZN170-11/4A 22-16ZN170-1A 22-16ZN170-21/2A 22-16ZN170-2A 22-16

Page 36: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Index of products

Type Page Type Page Type Page

0-35

ZN170-3/4A 22-16ZN170-3A 22-16ZR06F 19-11, 19-36ZR06K 16-7, 16-10, 16-12, 18-4, 18-6, 18-7,

18-9, 18-11, 18-13, 18-15, 18-21,

18-22, 19-36, 21-9, 21-13ZR100FA 6-8ZR10K-1 19-4, 19-15, 19-26, 19-31, 19-35,

19-39ZR10K-11/2 19-4, 19-15, 19-26, 19-39

ZR10K-3/4 19-4, 19-7, 19-9, 19-26ZR125FA 6-8ZR150FA 6-8ZR15MA 6-8ZR200FA 6-8

ZR20MA 6-8ZR25FA 6-8ZR25MA 6-8ZR32FA 6-8ZR32MA 6-8

ZR40FA 6-8ZR40MA 6-8ZR50FA 6-8ZR65FA 6-8ZR74CS 19-5, 19-8, 19-29, 19-33

ZR80FA 6-8ZS109M-3/4G 16-14ZS109M-3/4GS 16-14ZS109M-3/4H 16-14

Page 37: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

0-36 http://products.ecc.emea.honeywell.com/europe

Page 38: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room and Zone Control Page

LonWorks Controllers 1-2CentraLine Controllers 1-10LonWorks Operation 1-12Stand alone Controllers 1-15

Page 39: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-2

LonWorks Controllers

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

LonWorks Controllers

Multifunctional controller for 2- and 4- pipe induction/fan coil units, light and sunblinds. The Excel 12 is a room and zone controller which is suited for use in a wide variety of solutions.The Excel 12 is configurable through an LNS Plug-in, with CARE or any other LNS based tool. The HVAC part of the Excel 12 includes a multifunctional controller for induction units and fan coil units. Together with Web office console and Excel ZAPP, Excel 12 offers a complete room control and operation solution.

Controller for fan coil / lights / sunblinds, Excel 12

Control functions choice of 3 standard applications:• heating/cooling and 3-stage fan; 2x lights on/off, up to 2 lights

dimming or contant light control; sunblind positioning• 3x heating/cooling and 3-stage fan; 3x lights on/off, up to 2

lights dimming or contant light control; free inputs and outputs for access via LON

• 2x heating/cooling and 3-stage fan; 4x lights on/off, up to 2 lights dimming or contant light control; free inputs and outputs for access via LON

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile • profile 8501: SCC - Fan Coil (one instance)• profile 3040: Lamp Actuator (two instances)• profile 1060: Occupancy Sensor (one instance)• Closed-Loop Actuator Object 4: Sunblind Actuator (one

instance)

Hardware inputs • 7 analog inputs for sensors and setpoint adjustment• 4 digital inputs for push buttons for light, sunblind up/down

Hardware outputs • 2 analog outputs for actuators and/or lights• 11 digital outputs (6 triac, 5 relay) for 3-point actuators, lights,

sunblinds and fans

Power supply TypeVac; VA

24; 10 W7704D1008230; 20 W7704D1016

Page 40: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-3

LonWorks Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room temperature controller for chilled ceilings with condensation protection.For cooling with chilled ceiling and heating with radiator.

Controller for chilled ceilings, Excel 10

Heating output signal 2 triacs (24 V~, 250 mA) configurable for thermal, 3-pt, PWM or single/multistage control

Cooling output signal 2 triacs (24 V~, 250 mA) configurable for thermal, 3-pt, PWM or single/multistage control

Control functions heat only, cool only, heat/cool change over, heat and cool in sequence; dewpoint control, minimum hot water temperature control, zero energy band

Modes of operations occupied, standby, unoccupied, open window, frost protection, summer/winter change over, dewpoint, condensation

Obligatory inputs analogue input for room temperature sensor NTC20k; or apply additional XL10 wall-module with built in sensor on dedicated input terminal

Optional inputs • 2 universal inputs configurable for: window or occupancy or movement or change over or condensation or cold water

• 1 analogue inputs for roomhumidity• XL10 wall module input (T7460, T7560 -series) with

temperature sensor and other functions• network inputs for dewpoint/condensation• network input for temperature sensor, setpoint adjustment,

bypass and other functions

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8020

Power supply 24 Vac; 0,5 VA

Setpoint knob Built in room temperature sensor Built in occupancy extension button TypeoC

10 ... 35 • • W7763C1024- ... + • • W7763C1032- ... + – – W7763D1030

– – – W7763E1003

Page 41: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-4

LonWorks Controllers

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature controller for 2- and 4-pipe fan coil units.For heater, cooler, electric re-heat and 1,2,3-speed fans.

Controller for fan coil unit, Excel 10

Heating output signal 2 triacs (24V~, 250mA) configurable for thermal, 3-pt, PWM or single/multistage control

Cooling output signal 2 triacs (24V~, 250mA) configurable for thermal, 3-pt, PWM or single/multistage control

Fan output signal 3 relays (250V~, 3A)

Re-heat output signal 1 relay (250V~, 10A) (6A UL916)

Control functions heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band

Modes of operations occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over

Obligatory inputs 1 analogue input for room temperature sensor NTC20k; or apply additional XL10 wall-module with build in sensor on dedicated input terminal

Optional inputs • 1 digital input configurable for: window or occupancy or or movement or change over or airflow

• XL10 wall module input (T7460, T7560-series) with temperature sensor and other functions

• network input for temperature sensor, setpoint adjustment, bypass and other functions

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8020

Power supply 230 Vac; 30 VA

Fan speed outputs 3

Re-heat output yes

TypeW7752D2007

Page 42: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-5

LonWorks Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room temperature controller for 2- and 4-pipe fan coil units.For heater, cooler, electric re-heat and 1,2,3-speed fans.

Accessories

Controller for fan coil unit, compact, Excel 10

Heating output signal triacs (230V~, 500 mA) configurable for thermal, 3-pt, PWM or single/multistage control

Cooling output signal triacs (230V~, 500 mA) configurable for thermal, 3-pt, PWM or single/multistage control

Fan output signal relay (250V~, 3A)

Re-heat output signal relay (250V~, 10A) (6A UL916)

Control functions heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band

Modes of operations occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over

Obligatory inputs 1 analogue input for room temperature sensor NTC20k; or apply additional XL10 wall-module with build in sensor on dedicated input terminal

Optional inputs • 1 digital input configurable for: window or occupancy or or movement or change over or airflow

• 1 digital input for window contact• XL10 wall module input (T7460, T7560-series) with

temperature sensor and other functions• network input for temperature sensor, setpoint adjustment,

bypass and other functions

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8020

Powersupply

Fan speedoutputs

Re-heatoutput

Triac outputs230Vac

Auxiliary output signal Type

Vac; VA

230; 6 3 – 1x for cooling low voltage digital output for solid state relay(Carlo Gavazzi RS1A23D25-P64, 25 A)

W7754K1001

230; 6 3 • 4x for heat/cool – W7754P100024; 3 3 • 4x for heat/cool – W7754Q1008

230; 6 – • 2x for heat/cool AO variable speed fan W7754V1230230; 6 3 • 4x for heat/cool AO variable speed fan W7754R4431230; 6 3 – 2x for heat/cool – W7754S2230

Package of 8 terminal protection covers 230V modules (for wall/ceiling mounting) XAL-COV-L

Removable plug for LON tool with jumper for termination of LON network XAL-TERM

Page 43: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-6

LonWorks Controllers

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature controller for induction units, fan coil units without fan, radiators.For heater and cooler.

Controller for hydronic installations, Excel 10

Heating output signal 2 triacs (24V~, 250mA) configurable for thermal, 3-pt, PWM or single/multistage control

Cooling output signal 2 triacs (24V~, 250mA) configurable for thermal, 3-pt, PWM or single/multistage control

Control functions heat only, cool only, heat/cool change over, heat and cool in sequence; zero energy band

Modes of operations occupied, standby, unoccupied, open window, frost protection, summer/winter change over

Optional inputs • 1 digital input configurable for: window or occupancy or movement

• 1 analogue input for room temperature sensor NTC20k; or apply additional XL10 wall-module with built in sensor on dedicated input terminals

• XL10 wall module input (T7460, T7560-series) with temperature sensor and other functions

• network input for temperature sensor, setpoint adjustment, bypass and other functions

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8020

Power supply 24 Vac; 0,5 VA

TypeW7762B1019

Page 44: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-7

LonWorks Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room temperature controller for pressure (in)dependent, single/dual duct, VAV units, with built in Microbridge air flow sensor.For damper for cool air, re-heat peripheral re-heat and fan.The XL10 controllers support 8 triac outputs.

Controller for VAV units, Excel 10

Fan output signal 1 triac configurable for on/off or PWM

Re-heat output signal 1..3 triacs configurable for 3-pt, PWM or single/multistage control

Damper output signal 2 triacs for 3-pt control

Auxiliary output signal 1..3 triacs for up to 2 maintained outputs (1 triac each) or up to 1 maintained (1 triac) + pulsed output (2 triacs)

Control functions cooling only, heat/cool change over, cooling/reheat seq. with constant or modulating reheat airflow, cooling /radiator heating seq. with minimum heat, dual duct, dual duct mixed flow; cooling reheat radiator sequence, series/parallel fan, modulating fan

Control functions with 2 controllers

dual duct constant volume, dual duct mixed flow, dual duct no flow mixing

Modes of operations occupied, standby, unoccupied, open window, fan fail, summer/winter change over, night purge, morning warm up, smoke purge

Obligatory inputs • 1 analogue input for room temperature sensor NTC20k; or apply additional XL10-module with built in sensor on dedicated input terminals

• airflow

Optional inputs • XL10 wall module input (T7460, T7560-series) with temperature sensor and other functions

• network input for temperature sensor, setpoint adjustment, bypass and other functions

• 1 analogue input for discharge temperature or supply temperature sensor NTC20k

• 3 digital inputs configurable for: window or heat/cool change over or occupancy or status alarm

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8010

Power supply 24 Vac; 10 VA

Additional description Load per triac 24V~, 25..400mA. The maximum load for all triacs together is 400mA.

Model Typewith terminals inside W7751D2016/Uwith terminals outside W7751F2011/U

Page 45: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-8

LonWorks Controllers

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature controller for pressure (in)dependent, single/dual duct, VAV units, with built in Microbridge air flow sensor, and actuator.For cool air damper, re-heater/radiator and fan.

Controller with damper actuator for VAV units, Excel 10 Smart

Control output signal 2 triacs (24V~, 25..400mA) configurable for 3-pt, PWM or single/multistage control for:

• 3-pt actuator or,• 2-stage reheater or,• 1-stage reheater + fan, or• 1 fan

Control functions cooling only, heat/cool change over, cooling/reheat seq. with constant or modulating reheat airflow, cooling /radiatorheating seq. with minimum heat, dual duct, dual duct mixed flow, series/parallel fan

Control functions with 2 controllers

dual duct constant volume, dual duct mixed flow, dual duct no flow mixing

Modes of operations occupied, standby, unoccupied, open window

Obligatory inputs • 1 analogue input for room temperature sensor NTC20k; or apply additional XL10 wall-module with build in sensor on dedicated input terminals

• airflow

Optional inputs • XL10 wall module input (T7460, T7560-series) with temperature sensor and other functions

• network input for temperature sensor, setpoint adjustment, bypass and other functions

• 1 analogue input configurable for discharge or supply or room temperature sensor NTC20k

• network input for open window, occupancy, change over

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8010

Power supply 24 Vac; 6 VA

Torque 6 Nm

Housing (HxWxD) 142 mm; 103 mm; 76 mm

Protection class IP40 for all mounting directions

TypeW7751H3007

Auxilliary switch kit, with 2 SPDT freely adjustable switches, IP54, cable 1 m SSW2-1M

Page 46: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-9

LonWorks Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room temperature controller for constant volume air handling units, and heatpump air handlers.For heater, cooler (or heatpump) damper and fan.The XL10 CVAHU controllers support 8 triacs 24Vac (expanded version) or 5 triacs 24Vac plus 3 analogue outputs 4..20mA (analogue version).

Controller for constant volume air handling units (CVAHU), Excel 10

Heating output signal PWM, 3-pt floating, 1..4 stages or modulating 0..10V (analogue version only)

Cooling output signal PWM, 3-pt floating, 1..4 stages or modulating 0..10V (analogue version only)

Fan output signal 1 stage on/off

Damper output signal 3-pt floating

Changeover output signal 1 stage heat/cool

Auxiliary output signal 2 outputs with 1 stage on/off configurable for occupied status or free configurable via network

Control functions sequence control for damper/cooling/heating, staged with minimum on/off times or modulating control with damper minimum position; discharge air limit control; setpoint ramping; demand limit control; zero energy band

Modes of operations occupied, standby, unoccupied, open window, filter, economizer, indoor air quality, air flow, shutdown, smoke, intermittent fan, outside air lock out

Obligatory inputs 1 analogue input for room temperature sensor NTC20k or Pt3000; or apply additional XL10 wall-module with built in sensor on dedicated input terminals

Optional inputs • XL10 wall module input (T7460, T7560 -series) with temperature sensor and other functions

• network input for temperature sensor, setpoint adjustment, bypass and other functions

• 1 analogue input configurable for discharge, return or outdoor air temperature sensor NTC20k (or Pt3000)

• 1 digital input for bypass button• 2 digital inputs configurable for time clock, open window, filter,

economizer, indoor air quality, occupancy, air flow, shutdown, smoke

• network input for economizer

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8030

Power supply 24 Vac; 6 VA

Additional description The 24Vac triac outputs are rated at 500mA.

Model Triac outputs 24Vac Current outputs 4..20mA Typeexpanded version 8 – W7750B2011/Uanalogue version 5 3 W7750C2001

Page 47: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-10

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine Controllers

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.For heater, cooler, electric re-heat and 1,2,3-speed fans.

Accessories

Zone controller, SERVAL

Heating output signal triacs (500 mA) configurable for thermal, 3-pt or PWM control

Cooling output signal triacs (500 mA) configurable for thermal or 3-pt control

Fan output signal 3 relays (250V~, 3A)

Re-heat output signal relay (250V~, 10A) (6A UL916)

Control functions heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band

Modes of operations occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over

Obligatory inputs 1 temperature input for CentraLine wall module

Optional inputs configurable with COACH:• 1 digital input configurable for: window or occupancy or or

movement or change over or airflow• 1 digital input for window contact

Stand-alone operation yes

Network operation yes

Bus system LonWorks(R)

LonMark(R) profile 8020

Additional description Use COACH software from CentraLine to select the right control software for the required installation.

Power supply Re-heat output Triac outputs 230Vac Auxiliary output signal TypeVac; VA

230; 6 • 4x for heat/cool – CLSE1L23024; 3 • 4x for heat/cool – CLSE1L24

230; 6 • 4x for heat/cool AO variable speed fan CLSE2L230230; 6 – 2x for heat/cool, thermal

control only– CLSE3L230

Package of 8 terminal protection covers XAL-COV-L

Page 48: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-11

CentraLine Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is programmable and configurable using the COACHAX software.

Unitary Controllers without pressure sensor and without actuator

VAV controllers with pressure sensor and damper actuator 5 Nm

VAV controllers with pressure sensor and without actuator

Configurable wall modules

Accessories

LonWorks/BACnet free programmable unitary controller, LYNX

Hardwareinputs

Hardwareoutputs

Powersupply

BACnet (MSTP)connection

LonWorks(R)connection

Type

Vac; VA

1 universal 1 analog, 2 digital 24; 5 – directly connectable CLLYUL1012S4 universal 2 analog, 4 digital 24; 5 – directly connectable CLLYUL4024S

6 universal, 4 digital 3 analog, 8 digital 24; 5 – directly connectable CLLYUL6438S1 universal 1 analog, 2 digital 24; 5 directly connectable – CLLYUB1012S4 universal 2 analog, 4 digital 24; 5 directly connectable – CLLYUB4024S

6 universal, 4 digital 3 analog, 8 digital 24; 5 directly connectable – CLLYUB6438S

Hardwareinputs

Hardwareoutputs

Powersupply

BACnet (MSTP)connection

LonWorks(R)connection

Type

Vac; VA

– – 24; 9 – directly connectable CLLYVL0000AS4 universal 2 analog, 2 digital 24; 9 – directly connectable CLLYVL4022AS

6 universal, 4 digital 3 analog, 6 digital 24; 9 – directly connectable CLLYVL6436AS– – 24; 9 directly connectable – CLLYVB0000AS

4 universal 2 analog, 2 digital 24; 9 directly connectable – CLLYVB4022AS6 universal, 4 digital 3 analog, 6 digital 24; 9 directly connectable – CLLYVB6436AS

Hardwareinputs

Hardwareoutputs

Powersupply

BACnet (MSTP)connection

LonWorks(R)connection

Type

Vac; VA

4 universal 2 analog, 4 digital 24; 5 – directly connectable CLLYVL4024NS6 universal, 4 digital 3 analog, 8 digital 24; 5 – directly connectable CLLYVL6438NS

4 universal 2 analog, 4 digital 24; 5 directly connectable – CLLYVB4024NS6 universal, 4 digital 3 analog, 8 digital 24; 5 directly connectable – CLLYVB6438NS

Lynx wall module with room temperature sensor and backlit display CLCMTR71

Lynx wall module with room temperature and humidity sensor, and backlit display CLCMTR71-H

Lynx wall module with room temperature sensor and backlit display, LYNX schedule support

CLCMTR75

Lynx wall module with room temperature and humidity sensor, and backlit display LYNX schedule support

CLCMTR75-H

Installation box for Micro Lynx models (types .L00., .L10., .L40.) WB10707/U

Page 49: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-12

LonWorks Operation

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

LonWorks Operation

Excel ZAPP consists of a Radio Frequency handheld unit, room temperature sensors and a receiver. The receiver provides signals for a LonWorks(R) network. Components that can be controlled on the network are for example:

• Honeywell Excel 10 room controllers• Honeywell Excel 50 system controllers• sun blind controllers• lighting controllers• etc.

For offices hotels etc. with individual room control applications. For each room a handheld is applicable for manual operation of the room installations.

Handheld

Sensors, T7270

Receiver, W7070

Remote control system, Excel ZAPP

Manual operation functions

• occupancy• adjust setpoint temperature• adjust fanspeed• operate sunblinds• switch/dim lights• second light or other purpose• selection of predefined office styles; definition of office styles

can be done by the user, without any tools

LED functions for Handheld: battery test, child proof lock

Approvals CE, for RF approvals contact Honeywell for approval papers

Transceiver type for Receiver: LonWorks(R) FTT 10A

Mounting for Receiver: panel, wall, standard wall outlet

Additional description Up to 8 handhelds, and up to 8 sensors can be linked with one receiver. Attaching the handhelds to the receiver can be done easily without any tools.

Product description Output signal Power supply Batteries TypeVac; VA

ZAPP handheld RF: 868 MHz signal –; – included 2 x AAAlkaline cells

RT7070A2008

Product description Output signal Power supply Batteries TypeVac; VA

ZAPP room temperature sensor with setpoint adjustment, LED display, fan speed, occupancy,switching/dimming lights, operating sunblinds

RF: 868 MHz signal –; – included 2 x AAAlkaline cells

T7270B2009

ZAPP room temperature sensor with setpointadjustment

RF: 868 MHz signal –; – included 2 x AAAlkaline cells

T7270A2001

ZAPP room temperature sensor RF: 868 MHz signal –; – included 2 x AAAlkaline cells

T7270A2019

Product description Output signal Power supply Batteries TypeVac; VA

ZAPP receiver and antenna Echelon(R) LonTalk(R)protocol

24; 2 – W7070A2000

FTT Termination module XAL-TERM

Wallholder for RT7070A handheld RT70-HRD20-WALL

Page 50: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-13

LonWorks Operation

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Room temperature sensor for Excel 10/12 and Excel 50..800 controllers. Models available with setpoint adjustment, occupancy extension and fan switch.

Spare parts for all T7460 models

Spare parts for T7460B,C,D,E,F

Spare parts for T7460D,E,F

Spare parts for T7460C,E,F

Wall modules for EXCEL 5000 controllers

LED functions LED on or blinking in case of bypass, LED functions programmable with Excel 20..800 controllers

Temperature element NTC20k

Temperature range 10 ... 35 oC

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Models with setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.

Setpoint knob Extra setp. knob Occupancy switch Fan switch TypeoC oC

– – – – T7460A1001-5 ... 5 12 ... 30 – – T7460B1009-5 ... 5 12 ... 30 auto/bypass – T7460C1007-5 ... 5 12 ... 30 – auto/off/1/2/3 T7460D1005-5 ... 5 12 ... 30 auto/bypass auto/off/on T7460E1002-5 ... 5 12 ... 30 auto/bypass auto/off/1/2/3 T7460F1000

LON connection board T7460LONJACK

Setpoint range limiter T7460LIMITER

Blind cover, blue (25 pieces) WMSPS-1

Blind cover, white (25 pieces) WMSPS-2

Round knob, blue (25 pieces) WMSPS-3

Round knob, white (25 pieces) WMSPS-4

Setpoint wheel, blue (scale +/-5K) (25 pieces) WMSPS-8

Setpoint pack, consists of 1 blind cover white, 1 setpoint wheel blue (scale 12..30). 1 setpointwheel white (scale 12..30), 1 setpointwheel white, scale +/-5 (10 pieces)

WMSPS-9

Fanspeed knob (50 pieces) WMSPS-10

Occupancy button (50 pieces) WMSPS-11

Page 51: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-14

LonWorks Operation

http://products.ecc.emea.honeywell.com/europe

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature sensor with digital display, for Excel 10 and Excel 50..800 controllers. With setpoint adjustment, occupancy extension, fan speed button and on/off button. Model with R.H.-sensor.

Accessories

Spare parts

Wall modules for EXCEL 5000 controllers, with display

Display functions room temperature, setpoint temperature, occupancy status, fan speed status

Temperature element NTC20k

Temperature range 10 ... 40 oC

Setpoint knob -5 ... 5 oC

Extra setp. knob 12 ... 30 oC

Occupancy switch on/off

Fan switch configurable

Power supply 24 Vac; 2 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Tool-free configuration:• number of fan speeds• relative / absolute setpoint• enable/disable space temperature display• centigrade/fahrenheit

R.H. range R.H. sensing element R.H. output signal Wiring terminals Model Type%rh

– – – 7 blue knobs/wheel T7560A1000– – – 7 white knobs/wheel T7560A1026– – – 7 white knobs/wheel/fahrenheit T7560A1018

5 ... 90 capacitive 0..10V= 8 blue knobs/wheel T7560B10085 ... 90 capacitive 0..10V= 8 white knobs/wheel T7560B10245 ... 90 capacitive 0..10V= 8 white knobs/wheel/fahrenheit T7560B1016

LON/BACnet connection board T7460LONJACK

Blind cover for T7560 knobs (50 pieces) T7560BLINDS

Blind cover, blue (25 pieces) WMSPS-1

Blind cover, white (25 pieces) WMSPS-2

Round knob, blue (25 pieces) WMSPS-3

Round knob, white (25 pieces) WMSPS-4

Setpoint wheel, blue, unprinted (25 pieces) WMSPS-5

Setpoint wheel, white, unprinted (25 pieces) WMSPS-6

Page 52: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-15

Stand alone Controllers

1

2

3

4

5

6

7

8

10

9

11

12

13

14

Stand alone Controllers

Digital controller for individual zone control of terminal units in fan coil and air conditioning systems, with great applications flexibility. The controller provides position control of valves or dampers (for airside control), and is capable of mounting on a switching sub-base for manual control of the fan speed.The controller can be configured (with dipswitches) for the following applications:

• Heat / Cool changeover• Cooling only• Cooling + optional 2 stages On/Off Heating• Heating only• Heating + optional 2 stages On/Off Cooling• Heating + Cooling Sequence Control

Accessories

Room temperature controller 24Vac, modulating, on/off, T8078C

Control output signal 2 triacs for 1 valve open/close; 2 triacs for 2nd valve open/close or 2 on/off stages; max. load 8 VA /triac (24 V)

Control functions dipswitch settings for:• PI Modulating (3-position)• PI On/Off• thermal actuator control using TPM (=Thermal Predictive

Modulating)• proportional band• zero energy band

Temperature element NTC100k

Temp. setpoint range 15 ... 30 oC

Optional inputs remote sensor, remote setpoint adjustment, heat/cool changeover, energy savings contact

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Protection class IP30

Power supply 24 Vac; 1,2 VA

Additional description • easy system check with LED and PC-output port• easy commissioning with automatic valve pulsing• periodic valve excercise and synchronisation• remote sensor auto-detect

TypeT8078C1009

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Wall-plate to allow mounting onto different wall boxes (5 pieces) F42007789 001

Remote setpoint module (-5..+5 K) Q979B1029

Remote sensor and setpoint module (-5..+5 K) Q979C1036

Wall mounted space temperature sensor Q979A1020

Remote sensor for duct or terminal unit mounting (1.5m cable) T8109C1002

External pipe thermostat for automatic heat/cool changeover S4390A1004

Fan speed switching subbase (230 V) Q6360A1025

Page 53: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

1-16 http://products.ecc.emea.honeywell.com/europe

Page 54: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Plant Control Page

CentraLine Controllers 2-2CentraLine Workstations 2-14CentraLine Integration 2-17

Page 55: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-2

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine Controllers

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller can be applied for stand-alone operation, dial-up and in network systems.For all buildings.

Programmable universal BACnet Building Controller, EAGLE

Control software • free programmable with CentraLine CARE software• programmable with standard software modules

Hardware inputs Onboard inputs and external input modules available for:• measurement of temperature, relative humidity, pressure etc.• contact status from relays, thermostats etc.

Hardware outputs Onboard outputs or external output modules available for: • control devices like servomotors• switching devices like pumps, ventilators

Operator panels • Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.

• Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.

Management applications ARENA AX

Stand-alone operation yes

Bus system description • standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends

• standard BACnet MS/TP communication with other BACnet MS/TP devices

• Panel bus for communication to Panel I/O modules via RS485• LonWorks(R) bus with the external USB-LON interface adapter

IF-LON. LonWorks(R) transceiver type FTT10A

Mounting • in cabinets• in fuse boxes conforming with standard DIN43880, and having

a slot height of max. 45 mm• in cabinet front doors (using accessory MVC-80-AC2)• on walls (using accessory MVC-80-AC1)

Protection class IP20

Power supply 19..29 Vac or 20..30 Vdc ; 9 VA

Additional description • LonWorks(R) connection via external USB-LON interface adapter IF-LON

• Panel bus directly connectable• Real-time clock back-up with goldcap capacitor for 72 hours

buffer

Page 56: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-3

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

EAGLE Plant Controller

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection

LON I/O modules, -configurable LED functions, - safety positions, - short circuit protection

Sockets (push-in) for modules (supplied with bridge connector and swivel label)

Sockets (screw- type) for modules (supplied with bridge connector and swivel label)

Product description TypeBACnet IP and MS /TP controller without onboard IOs CLEA2000B01BACnet IP and MS /TP controller without onboard IOs, with HMI CLEA2000B21BACnet MS /TP controller with 14 onboard IOs CLEA2014B01BACnet MS /TP controller with 14 onboard IOs, with HMI CLEA2014B21BACnet MS /TP controller with 26 onboard IOs CLEA2026B01BACnet MS /TP controller with 26 onboard IOs, with HMI CLEA2026B21external USB-LON interface adapter IF-LON

Product description Type8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact CLIOP821A8 analog output module 0..10Vdc, 3-pt, binary 0/10V CLIOP822A8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer CLIOPR822A12 binary input module for contact or totalizer contact 20 Hz CLIOP823A6 relay output module SPDT 250V, 2(1) A, feedback CLIOP824A6 relay output module SPDT 250V, 2(1) A, feedback; with override switch CLIOPR824A3-point control output module, with override switch; for 1 actuator CLIOPR825A

Product description Type8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact CLIOL821A8 analog output module 0..10Vdc, 3-pt, binary 0/10V CLIOL822A8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer CLIOLR822A12 binary input module for contact or totalizer contact 20 Hz CLIOL823A6 relay output module SPDT 250V, 2(1) A, feedback CLIOL824A6 relay output module SPDT 250V, 2(1) A, feedback; with override switch CLIOLR824A

Product description TypeSocket for 1 analog input or output module XS821-22Socket for 1 binary input module XS823Socket for 1 relay or 3-pt output module (supplied with additional cross connector) XS824-25

Product description TypeSocket for 1 analog input or output module XSU821-22Socket for 1 binary input module XSU823Socket for 1 relay or 3-pt output module (supplied with additional cross connector) XSU824-25

Page 57: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-4

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A

Cables connecting controller with:

Accessories for I/O modules

Extra parts for EAGLE controller

Accessories for Mixed I/O modules and EAGLE

Additional product for controllers

Product description TypeMixed I/O module with push-in terminals CLIOP830A

Product description TypeMixed I/O module with screw terminals CLIOP831A

Laptops; 3 m, shielded, RJ45 plug with clip XW885

Manual disconnector module for analog/binary inputs and analog outputs XS812

Manual disconnector module for relay outputs XS812RO

10 auxiliary terminal blocks XS814

20 cross connectors for connection of 6 relay commons XS815

10 connector bridges XS816

10 swivel labels XAL10

Removable terminal plugs, push-in type; complete set of 9 plugs (for terminals 1 - 47); for the CLEA2014Bxx and CLEA2026Bxx

TPU-45-01

Removable terminal plugs, push-in type; complete set of 3 plugs (for terminals 1 - 47); for the CLEA2000Bxx

TPU-11-01

Terminal cover (color: RAL9011); package of 20; for EAGLE Controllers MVC-80-AC1

Front door mounting accessory (color: RAL9011); package of 20; for EAGLE Controllers

MVC-80-AC2

Strain relief; package of 10; for MVC-40x-xxxxxx and MVC-80x-xxxxxx Controllers MVC-40-AC3

10 auxiliary terminal blocks XS830

10 auxiliary terminal blocks with 500 ohm resistors for current inputs XS831

10 connector bridges XS816

CentraLine Touch operator interface CLMMI00N31

LON connection and termination module XAL-TERM

Page 58: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-5

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller can be applied for stand-alone operation, dial-up and in network systems.For all buildings.

Programmable, universal BACnet Building Controller, FALCON

Control software • free programmable with CentraLine CARE software• programmable with standard ModAL software modules

Hardware inputs input modules available for:• measurement of temperature, relative humidity, pressure etc.• contact status from relays, thermostats etc.

Hardware outputs output modules available for:• control devices like servomotors• switching devices like pumps, ventilators

Operator panels full functional operation via Internet Browser and any standard Notebook, Laptop or PC. Access options are RS232, USB port or Ethernet.

Management applications ARENA

Stand-alone operation yes

Bus system description • standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends

• standard LonWorks(R) communication with field I/O's and field devices

Transceiver type LonWorks(R) FTT10A

Application cards compact Flash (CF) card port for optional CF cards Type 1 and 2, in order to extend the onboard trend buffer.

Mounting DIN rail and wall

Protection class IP20

Type of terminals plug-in screw terminals (LON, power, onboard I/O's), RJ45 (Ethernet, LON)

Memory back-up goldcap capacitor for 72 hours buffer

BACnet IP yes

Power supply 24 Vacdc; 8 VA

Modem connection directly connectable

LonWorks(R) connection directly connectable

Additional description Input/output modules to be connected to the DDC-controller via the LonWorks(R) bus connector. Embedded Web-server for direct Access via Internet Browser. BACnet PICS and BTL test certificate on request.

Product description TypeController with 52 Network Variables CLFA50LB0CController with 104 Network Variables CLFA100LB0CController with 300 Network Variables CLFA300LB0CController with 600 Network Variables CLFA600LB0C

Uninterrupted power supply RIN-APU24-2

Page 59: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-6

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.

Mini PANTHER controller; 4 AI, 4 DI, 2 AO, 3 DO

HVAC controller with configurable applications, PANTHER

Control software application card with control software, with hundreds of different selectable applications and parameter settings

Hardware inputs • Analog Inputs (AI) for NTC20k sensors• Digital Inputs (DI) for potential free contacts or 24 Vdc

Hardware outputs • Analogue Outputs (AO) 0..10 Vdc• Digital Outputs (DO) 24 Vac

Management applications ARENA / RANGER

Stand-alone operation yes

Bus system description • LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER

• models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)

• models available with M-bus, to import heating- , cooling- or electric energy values; hot/cold water- or oil/gas volumes from M-Bus metering devices

Transceiver type LonWorks(R) FTT10A

Application cards with removable card for communication, application storage, operating system and local language texts for operator panel

Mounting DIN rail or cabinet front door

Protection class IP20, IP54 with door mounting accessories (supplied)

Type of terminals screw terminals with terminal block

Memory back-up goldcap capacitor for 72 hours buffer

Power supply 24 Vac; 10 VA

C-bus connection directly connectable via application card

LonWorks(R) connection directly connectable via application card

M-bus connection directly connectable via application card

Additional description Use COACH software from CentraLine to select the right control software for the required installation.

Product description TypeMini PANTHER controller with LON + C-Bus CLPA13LC02Mini PANTHER controller with LON + C-Bus + operator panel CLPA13LC12Mini PANTHER controller with LON + M-Bus CLPA13LM02Mini PANTHER controller with LON + M-Bus + operator panel CLPA13LM12

Page 60: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-7

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

PANTHER controller; 8 AI, 4 DI, 4 AO, 6 DO

Accessories for M-bus PANTHER

Additional product for PANTHER controllers

COACH for selection of control software

Panther Demo Kits

Product description TypePANTHER controller with LON + C-Bus CLPA21LC02PANTHER controller with LON + C-Bus + operator panel CLPA21LC12PANTHER controller with LON + C-Bus + operator panel Cyrillic CLPA21LC22PANTHER controller with LON + M-Bus CLPA21LM02PANTHER controller with LON + M-Bus + operator panel CLPA21LM12

Adapter PW3

Adapter cable XW586

External Operator panel with cable (5 m); wall/door mounting CLMMI00N22

CentraLine Touch operator interface CLMMI00N31

Connection cable between CL-Touch/PC and PANTHER/TIGER XW585

Application card Free Programmable; with Flash-EPROM, modem, C-bus, LON-bus XD50B-FCL

Rubber ring for front door mounting (IP54) XL50-ACC3

LON connection and termination module XAL-TERM

COACH for End user CLCH2EL1

COACH for Expert End user CLCH2EL2

COACH for Partner CLCH2EL3

COACH for Expert Partner CLCH2EL4

Demo kits

Product description TypePanther DEMO Kit 240V, 3 PIN Plug with controller CLPD01240WPanther DEMO Kit 240V, SCHUKD 2 PIN plug and controller CLPDU02240WPanther DEMO Kit 110V, SCHUKD 2 PIN plug and controller CPDU01110W

Page 61: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-8

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine controller with relay outputs, for HVAC applications. The controller can be applied for stand-alone operation, dial-up and in network systems.

TIGER controller; 8 AI, 14 DI, 4 AO, 12 DO (3 SPDT, 9 SPST)

Additional products for TIGER controllers

Additional products for CLTG38L01

COACH for selection of control software

HVAC controller with configurable applications, and relay outputs, TIGER

Control software control software embedded, with hundreds of different selectable applications and parameter settings

Hardware inputs • Analog Inputs (AI) for NTC20k sensors, 0..10 V, 0/4..20 mA active sensors (apply signal separator!) or slow switching dry contact

• Digital Inputs (DI) for potential free contacts, 24 Vdc or 24 Vac

Hardware outputs • Analogue Outputs (AO) 0..10V=• Digital Outputs (DO) relay contact SPDT or SPST

Management applications ARENA / RANGER

Stand-alone operation yes

Bus system description LonWorks(R) bus for data exchange with other TIGER, or PANTHER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER

Transceiver type LonWorks(R) FTT10A

Mounting DIN rail

Protection class IP30

Type of terminals screw terminals with terminal block

Memory back-up goldcap capacitor for 72 hours buffer

Power supply 24 Vac; 15 VA

LonWorks(R) connection directly connectable

Additional description Use COACH software from CentraLine to select the right control software for the required installation.

Product description TypeTIGER controller with LON CLTG38L01TIGER controller with LON + operator panel CLTG38L11

I/O expansion board, 8 AI, 14 DI, 4 AO, 12 DO (3 SPDT, 9 SPST) with DIN rail mounting clip and flat cable (350 mm). Max. 1 board/controller.

CLTG38EXPN01

External Operator panel with cable (5 m); wall/door mounting CLMMI00N22

CentraLine Touch operator interface CLMMI00N31

Connection cable between CL-Touch/PC and PANTHER/TIGER XW585

LON connection and termination module XAL-TERM

Signal separator GT4

External operator panel with door mounting kit and flat cable (1.5 m) CLTG00MMIN01

COACH for End user CLCH2EL1

COACH for Expert End user CLCH2EL2

COACH for Partner CLCH2EL3

COACH for Expert Partner CLCH2EL4

Page 62: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-9

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

DDC controller for all HVAC control applications, and building automation functionalities. The controller can be applied for stand-alone operation, dial-up and in network systems.For all buildings.

LION Plant Controller

Panel I/O modules, -configurable LED functions, - safety positions, - short circuit protection

Programmable universal HVAC controller, CentraLine LION

Control software • configurable with COACH software• free programmable with CARE software• programmable with standard ModAL software modules

Hardware inputs Panel Bus and LON Bus input modules available for:• measurement of temperature, relative humidity, pressure etc.• contact status from relays, thermostats etc.

Hardware outputs Panel Bus and LON Bus output modules available for:• control devices like servomotors (configuration of safety

position is possible)• switching devices like pumps, ventilators

Operator panels RS232 port available for operator panels CLMMI00N22/CLMMI00N31; these panels can be used for adjustment of setpoints, alarm limits, fixing in/outputs, override functions, graphic trending etc.

Stand-alone operation yes

Bus system description • communication bus ("physical C-bus" or "C-bus over LON")• LonWorks(R) bus• Panel bus for communication to Panel I/O modules

Transceiver type LonWorks(R) FTT10A

Mounting DIN rail

Protection class IP30

Memory back-up goldcap capacitor for 72 hours buffer

Power supply 24 Vacdc; 5 VA

Modem connection directly connectable

C-bus connection directly connectable

LonWorks(R) connection directly connectable

Panel bus connection directly connectable

Product description TypeController CLLIONLC01

Product description Type8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact CLIOP821A8 analog output module 0..10Vdc, 3-pt, binary 0/10V CLIOP822A8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer CLIOPR822A12 binary input module for contact or totalizer contact 20 Hz CLIOP823A6 relay output module SPDT 250V, 2(1) A, feedback CLIOP824A6 relay output module SPDT 250V, 2(1) A, feedback; with override switch CLIOPR824A3-point control output module, with override switch; for 1 actuator CLIOPR825A

Page 63: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-10

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Sockets (push-in) for modules (supplied with bridge connector and swivel label)

Sockets (screw- type) for modules (supplied with bridge connector and swivel label)

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A

Cables connecting CLLIONLC01 with:

Adapter cable for controllers with 9 pin sub-D connector

Accessories for I/O modules

Accessories for Mixed I/O modules

Additional product forLION controllers

Product description TypeSocket for 1 analog input or output module XS821-22Socket for 1 binary input module XS823Socket for 1 relay or 3-pt output module (supplied with additional cross connector) XS824-25

Product description TypeSocket for 1 analog input or output module XSU821-22Socket for 1 binary input module XSU823Socket for 1 relay or 3-pt output module (supplied with additional cross connector) XSU824-25

Product description TypeMixed I/O module with push-in terminals CLIOP830A

Product description TypeMixed I/O module with screw terminals CLIOP831A

Modem; 1,8 m, RJ45 9 pin sub-D XW586

CLMMI00N22 Operator Interface; 5 m, shielded, RJ45 plug with clip XW882

Laptops; 3 m, shielded, RJ45 plug with clip XW885

Adapter cable length 0,2 m, shielded, RJ45 - 9 pin sub-D; XW884 + XW882 (=XW582) connects CLMMI00N22 with controller; XW884 + XW885 (=XW585) connects PC with controller

XW884

Manual disconnector module for analog/binary inputs and analog outputs XS812

Manual disconnector module for relay outputs XS812RO

10 auxiliary terminal blocks XS814

20 cross connectors for connection of 6 relay commons XS815

10 connector bridges XS816

10 swivel labels XAL10

10 auxiliary terminal blocks XS830

10 auxiliary terminal blocks with 500 ohm resistors for current inputs XS831

10 connector bridges XS816

External Operator panel with cable (5 m); wall/door mounting CLMMI00N22

CentraLine Touch operator interface CLMMI00N31

LON connection and termination module XAL-TERM

Page 64: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-11

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

The SymmetrE building management system redefines what to expect from monitoring and control of your heating, ventilation and air conditioning equipment. The scalable, open SymmetrE system brings your buildings occupant needs, operational issues and budget pressures into perfect balance. You get an unparalleled solution that helps simplify facility management, boost productivity and reduce costs.SymmetrE delivers an intelligent workstation with the full suite of tools you and your staff need. You can view and control subsystems, access and analyze data, manage equipment maintenance, see Intranet and Internet pages and generate graphs, charts and reports directly from your desktop.You also benefit from a building management system thats truly open. SymmetrEs unique technology takes full advantage of leading open standards, permitting you to create an integrated system with transparent communications from third-party subsystems directly to SymmetrE.Theres no need for gateways, simplifying configuration, installation and maintenance. SymmetrE also permits you to control many more points, while enabling you to access the full data-gathering capabilities of your controllers at your desk.SymmetrE goes a quantum leap beyond traditional control by delivering cuttingedge data management applications. Its software helps you trans-late raw data into clear insights to help maximize facility performance and enhance your bottom line. SymmetrE provides:

• Data collection in intervals from one second to one day• Standard and customized reports• Historical records of all event information and operator actions• Access to Internet and Intranet information without leaving the display• Trending capabilities• Ability to retrieve and analyze archived data

The Base Packages include the indicated point database, Excel 5000 Direct interface, LonWorks Interface, 1 Station, 4 Station Browsers, Quick Builder, Display Builder, Microsoft Excel Data Exchange, Network Server, Web Toolkit and 1 free interface from the drop-down list of Additional Free Interface in Section 3

Base Packages

Database Expansion

Upgrades

SymmetrE Building Management Workstation, R410

Product description TypeSymmetrE Base Package 1 - 250 Point database SYM-BASE01SymmetrE Base Package 1 - 500 Point database SYM-BASE02SymmetrE Base Package 1 - 1000 Point database SYM-BASE03SymmetrE R410 Software on DVD SYM-ZZDVD410

Product description Type250 Point Adder to Database Size SYM-DBP00250

Product description TypeSYM Upgrade Unit - Release Minus 1 SYM-UPGDR1SYM Upgrade Unit - Release Minus 2 SYM-UPGDR2SYM Upgrade Unit - Release Minus 3 SYM-UPGDR3SYM Upgrade Unit - Release Minus X SYM-UPGDRX

Page 65: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-12

CentraLine Controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

SymmetrE options

SymmetrE Network Adaptors

LON I/O modules for CentraLine controllers.• cabinet, DIN-rail, fuse box, or wall mounting• override switches and potentiometer operation• LED functions configurable• safety positions configurable• fixed terminals• power supply 24 Vac• short-circuit protected

LON I/O modules

Sockets for modules (supplied with bridge connector and swivel label)

Product description TypeUpgrade Browser Client to Full Station Client SYM-STB-UP-STNLNS Server SYM-OP-LNSBACnet Client Interface SYM-IF-BACNETBACnet Server SYM-OP-BACSERVExcel 5000 Direct Dial-Up Interface SYM-IFXL5DIRDIALAlarm Pager SYM-OP-ALMPAGMicrosoft Excel Data Exchange SYM-NW-MEDEModbus Interface SYM-IF-MODBUSFidelio Hotel Booking System Interface SYM-OP-FIDELIOOPC Client Interface SYM-IF-OPCCLOPC Server SYM-NW-OPCSERVOPC Data Transfer - Local SYM-OP-DTXLUpgrade to LNS 3.2 SYM-OP-LNSUPGOpenViewNet Interface SYM-IF-OVNEasy Mobile Services SYM-OPEASYMB

C-Bus/TCP/IP adapter for one C-Bus CLIF-CBUS1-PC

C-Bus/TCP/IP adapter for two C-Busses CLIF-CBUS2-PC

LON I/O modules

Product description Type8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact CLIOL821A8 analog output module 0..10Vdc, 3-pt, binary 0/10V CLIOL822A8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer CLIOLR822A12 binary input module for contact or totalizer contact 20 Hz CLIOL823A6 relay output module SPDT 250V, 2(1) A, feedback CLIOL824A6 relay output module SPDT 250V, 2(1) A, feedback; with override switch CLIOLR824A

Product description TypeSocket for 1 analog input or output module XS821-22Socket for 1 binary input module XS823Socket for 1 relay or 3-pt output module (supplied with additional cross connector) XS824-25

Page 66: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-13

CentraLine Controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

Accessories for I/O modules

Manual disconnector module for analog/binary inputs and analog outputs XS812

Manual disconnector module for relay outputs XS812RO

10 auxiliary terminal blocks XS814

20 cross connectors for connection of 6 relay commons XS815

10 connector bridges XS816

10 swivel labels XAL10

CentraLine LON Network Interfaces

Product description TypeLON Network Interface PCC10 as PCMCIA card (LAPTOP Use) / FT-10 incl. cable 2 conductors, flying leads PCC10KIT

Product description TypeLON Network Interface PCLTA-21 as PCI card (Desktop PC use) / FT-10 PCLTA21

Product description TypeRemote access network interface iLON10 (Continental Europe plug) / FT-10 iLON10EU

Product description TypeLON Network Interface U10 on USB (LAPTOP Use) / FT-10 U10

LON termination module XAL-TERM

Page 67: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-14

CentraLine Workstations

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine Workstations

MMI with a backlit LCD screen capable of displaying West European, East European, Turkish, and Cyrillic characters. Suitable for use as a desk-top device or for installation in a cabinet door. Bus-wide access to all CentraLine plant controllers on the same bus.Kit supplied for panel door mounting (IP54)

Cable

Touch Screen 8-inch color operator interface. For use with CentraLine AX and FALCON web-served graphical pages.It includes audio, Wi-Fi, and a wired IP connection.The interface is based on a fanless Atom-powered PC platform which has been specially configured to enable easy set-up. It uses a custom-embedded Windows XP running Browser in kiosk mode.

Features:• 800 x 600 pixels• flat front panel and low profile• wall or panel-mounting• power supply and mounting kit included (IP64)

CentraLine External MMI

TypeCLMMI00N22

Connection cable between MMI and PANTHER/TIGER XW582

Connection cable between MMI and LION XW882

CentraLine Touch Screen operator interface, CLMMI8

TypeCLMMI8-1

Page 68: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-15

CentraLine Workstations

2

3

4

5

6

7

8

10

9

11

12

13

14

CL Touch is an easy-to-operate and robust operator unit for the entire CentraLine range of plant controllers. The touch-panel operation screens allow for easy and selfexplanatory operation by finger-tip or by touch-pen (supplied). User-configurable fast-access lists can contain selected datapoints, time programs, and parameters, thus permitting plantoriented and customer-oriented operation.Features:

• color TFT graphic touch screen display 86 x 115 mm• uses password protection mechanism from connected controllers• local languages: English (US), English (UK)French, Spanish, German, Italian, Swedish, Japanese,

Dutch• uniform operation screens, even with different controllers• automatic detection and communication with connected controllers• upgrade for existing controllers to touch-screen operation• bus-wide operation• Ethernet, RS232C, USB interfaces• panel door mounting, IP65• power supply 24Vac or 24Vdc

Cable

Spare parts

CentraLine Touch operator interface

TypeCLMMI00N31

Connection cable between CL-Touch/PC and PANTHER/TIGER XW585

Connection cable between CL-Touch/PC and LION XW885

Bag with all accessories (accessories are also shipped with the CL Touch) CLMMI00N31-ACC

Page 69: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-16

CentraLine Workstations

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The ARENA is a Web based LON Workstation for small and medium size systems. It allows a maximum of 4 local sites and in addition the remote access to CentraLine systems through LAN or modem. Furthermore it is possible to operate the ARENA with a browser on a client PC and this requires not further software.Together with the configuration tool COACH and CARE, all system specific data is accessible locally and remotely. All CentraLine based control systems for e.g. room temperature, supply temperature, boiler temperature, and air humidity applications can be operated and monitored with ARENA.The ARENA license includes a graphic editor, which can create a completely independent graphic user interface for non-technical users.

• Lowest engineering effort due to plug and play functionality, automatic detection of all CentraLine devices within one or more sites. Automatic detection of C-Bus devices with the new C-Bus interface.

• Includes graphic editor with library of drawing symbols for the creation of system graphics, graphic navigation, and operation pages.

• Operation and monitoring of 4 local and up to 100 remote systems.• Operation independent from remote software. The ARENA remote function does not need extra

software. Only the Microsoft(R) Internet Explorer 8.0 or higher is required on the client PC.• Advanced building management features: powerful alarm and alarm routing functions (printer, e-

mail (Fax and SMS functions via services of the email provider), other ARENAs, history files, statistics), enhanced graphical trending with customizable display and export into MS Excel. Automatic database management with additional plugin 'scheduled export'.

• Sophisticated user privileges, with individual access, visibility and operation rights.• Openness: LON based system. Trends data export for other energy management software suites.

C-Bus interfaces

Workstation software, ARENA

Model TypeMax. 10 controllers per local system (4 local systems), contains 1 Arena to Arena connection CLAR2SL10Max. 120 controllers per local system (4 local systems), contains 1 Arena to Arena connection CLAR2SL99Upgrade from CLAR2SL10 to CLAR2SL99 CLAR2UL99C-Bus driver for Arena CLAR2DRV-CBUSRemote LON system driver CLAR2DRV-LONRDriver for unlimited number of Arena to Arena connections CLAR2DRV-A2A

Arena C-Bus/TCP/IP adapter for one C-Bus CLIF-CBUS1-PC

Arena C-Bus/TCP/IP adapter for two C-Busses CLIF-CBUS2-PC

Page 70: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-17

CentraLine Integration

2

3

4

5

6

7

8

10

9

11

12

13

14

CentraLine Integration

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.Hardware inputs/outputs

• CentraLine LON I/O modules (CLIOL)• external I/O modules with universal inputs and outputs for: measurement of temperature, relative

humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.

• M2M models with integrated inputs and outputsIntegration

• Honeywell C-Bus via B-Port• Honeywell Evohome Systems• Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX

IP, M-bus, oBiX, and SNMP• See also System drivers part

Communication cards• 2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)• M2M models have 1 expansion slot

Web server• Supports most common browsers• Different profiles are supported, profiles where Java plugin is needed but also profiles where only

HTML is required• Mobile device support via HTML 5, iOS, Adroid...

HAWK 600

HAWK 200

HVAC and Integration controller, HAWK

Control software free programmable with COACHAX

Management applications ARENAAX

Stand-alone operation yes

Mounting DIN rail or wall mounting

Product description TypeHAWK 660, Java heap memory 96 MB CLAXHAWK660HAWK 650, Java heap memory 48 MB CLAXHAWK650HAWK 640, Java heap memory 48 MB, resource count max 1000kRU CLAXHAWK640HAWK 630, Java heap memory 48 MB, resource count max 450kRU, drivers max 200 points (EIB/KNX 500 points) CLAXHAWK630

Product description TypeHAWK 250, Java heap memory 48 MB CLAXHAWK250HAWK 240, Java heap memory 16 MB CLAXHAWK240HAWK 230, Java heap memory 16 MB; max. 450kRU, 200 (EIB 500) points/network CLAXHAWK230HAWK 220, Java heap memory 16 MB; max. 400kRU, 8 devices/network, 34 points NDIO, max one additional Network, max 100 points per network

CLAXHAWK220

Page 71: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-18

CentraLine Integration

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The HAWK M2M combines integration, integrated control, supervision, data logging, alarming scheduling and network management functions, integrated I/O, integrated power supply module and optional GPRS modem connectivity with Internet connectivity and Web serving capabilities

HAWK 600 upgrades

HAWK 200 upgrades

HAWK M2M upgrades

HAWK revision upgrade

DIN-rail I/O modules; max. 4xIO16 or 2xIO16 + 1xIO34 (not for M2M)

Communication cards, for expansion slots

Product description TypeHAWK, Java heap memory 16 MB; max. 300kRU; only Niagara/internal Driver CLAXHAWK216MHAWK, Java heap memory 16 MB; max. 300kRU; only Niagara/internal Driver; with GPRS CLAXHAWK216MGPHAWK, Java heap memory 16 MB; max. 450kRU; 200 (EIB/KNX 500) points/network CLAXHAWK236MHAWK, Java heap memory 16 MB; max. 450kRU; 200 (EIB/KNX 500) points/network; with GPRS CLAXHAWK236MGPHAWK, Java heap memory 16 MB; no license restrictions CLAXHAWK246MHAWK, Java heap memory 16 MB; no license restrictions; with GPRS CLAXHAWK246MGPHAWK, Java heap memory 48 MB; no license restrictions CLAXHAWK256MHAWK, Java heap memory 48 MB; no license restrictions; with GPRS CLAXHAWK256MGP

Upgrade HAWK 630 to 640 CLAXHAWK63UP64

Upgrade HAWK 640 to 650 CLAXHAWK64UP65

Upgrade HAWK 650 to 660 CLAXHAWK65UP66

Upgrade HAWK 220 to 230 CLAXHAWK22UP23

Upgrade HAWK 230 to 240 CLAXHAWK23UP24

Upgrade HAWK 240 to 250 CLAXHAWK24UP25

Upgrade HAWK 216 to 236 CLAXHAWK16UP36

Upgrade HAWK 236 to 246 CLAXHAWK36UP46

Upgrade HAWK 246 to 256 CLAXHAWK46UP56

Upgrade of HAWK and associated drivers, one revision upgrade CLAXHAWKRUP

Upgrade of HAWK and associated drivers, two or more revision upgrade CLAXHAWKRUP2

8 universal inputs, 4 relay outputs, 4 0..10 Vdc analog output CLAXHAWKIO16

16 universal inputs, 10 relay outputs, 8 0..10 Vdc analog output; note: this module includes an on-board 24 Vac/dc power supply

CLAXHAWKIO34

LON adapter CLAXHAWKIFLON

RS-232 adapter CLAXHAWKIF232

2 x RS-485 adapter CLAXHAWKIF485

Page 72: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-19

CentraLine Integration

2

3

4

5

6

7

8

10

9

11

12

13

14

Interface card GPRS (not for M2M)

Power supply for 1 HAWK module (not for M2M)

System drivers

Video drivers

COACH software

GPRS adapter for HAWK 2/6 series, use one of the communication slots CLAXIFGPRS

External antenna and bracket for GPRS modem CLAXIFGPRSACC

Wall adapter, input 100..240 Vac, 50/60 Hz, European plug CLAXWPMEU

Wall adapter, input 100..240 Vac, 50/60 Hz, UK plug CLAXWPMUK

Power supply module, input 24 Vac/dc, DIN rail mounting CLAXNPBPWR

Power supply module, input 230 Vac 50/60 Hz, DIN rail mounting CLAXNPBPWR230

Honeywell C-Bus driver via B-Port CLAXDRBPORT

Honeywell Evohome driver CLAXDREVO

Honeywell Galaxy Driver CLAXDRGLX

Honeywell Galaxy 1 Panel Driver CLAXDRGL1

Hometronic Driver CLAXDRHTR

Helvar driver CLAXDRHLV

SMS service for HAWK CLAXDRSMS

Micros Fidelio hotel room booking system Driver (IP) CLAXDRFIDELIO

Horstmann driver CLAXDRHRSM

Global Cache driver CLAXDRGCIR

Flex Driver over R232 or RS485 CLAXDRFLX

Protec fire panel driver CLAXDRPRO

Resol water heating controller driver CLAXDRRSL

Table Driver CLAXDRTBL

Andover AC256 Driver CLAXDRACX

Andover Infintity Continuum Driver CLAXDRINF

Axis Video 4 Cameras driver CLAXDRAXI

Dedicated Micros DVR 4 Cameras driver CLAXDRDED

Milestone NVM 4 Cameras driver CLAXDRMIL

COACHAX for end users CLAXCOACH

COACHAX for system integrators (1 year license) CLAXCOACHSI

Page 73: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-20

CentraLine Integration

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.Features:

• Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser

• FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used• Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP

and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol

• Certified BACnet drivers are available (OWS, AWS)• Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a

non-Java UI for browsers• Supports an unlimited number of users over the Internet / Intranet with a standard web browser,

depending on the host PC• Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML

text formats• 'Audit Trail' of database changes, database storage and backup, global time functions, calendar,

central scheduling, control, and energy management routines.• Sophisticated alarm processing and routing, including e-mail and SMS• Password protection and security using standard Java authentication and encryption techniques

with optional security supported via an external LDAP connection• HTML-based help system that includes comprehensive on-line system documentation• Supports multiple HAWK stations connected to a local Ethernet network, or the Internet• A 'Small Building System' version is available for up to ten HAWKs

Web based Supervisor software, ARENA AX

Model TypeARENA AX Supervisor Software CLAXARENAARENA AX Supervisor Software for single HAWK, only available in bulks (more then 20) CLAXARENASBS01ARENA AX Supervisor Software Small Building System, for up to 10 HAWK and 10 FALCON CLAXARENASBS10ARENA AX Supervisor Software for LINUX CLAXARENALINUXARENA AX Supervisor Software for 64 bit Windows OS CLAXARENAWOS64Alarmportal CLAXARENAAPC

Page 74: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-21

CentraLine Integration

2

3

4

5

6

7

8

10

9

11

12

13

14

CL AX ARENA open system Drivers

CL AX Database Drivers

CL AX Video Drivers

CL ARENA AX Upgrades

BACnet IP Driver, OWS certified, with 500 BACnet points CLAXDRBACOWS

Additional BACnet AWS feature for ARENA AX CLAXDRBACAWS

Additional BACnet Server Export feature for ARENA AX CLAXDRBACEXP

Additional 500 BACnet points CLAXDRBAC500

OPC Driver with 500 OPC points CLAXDROPC

Additional 500 OPC points CLAXDROPC500

SNMP Driver with 500 SNMP points CLAXDRSNMP

Additional 500 SNMP points CLAXDRSNMP500

EIB IP Driver with 500 EIB points CLAXDREIB

Additional 500 EIB points CLAXDREIB500

Modbus TCP Driver with 500 Modbus TCP points CLAXDRMTCP

Additional 500 Modbus TCP points CLAXDRMTCP500

LON IP Driver with 500 LON points CLAXDRLONIP

Additional 500 LON points CLAXDRLONIP500

OBIX Driver for non-Niagara point connectivity with 500 OBIX points CLAXDROBX

Additional 500 OBIX points CLAXDROBX500

OPC Client alarm and event notification driver with 500 points CLAXDROPE

Additional 500 points for OPC alarm and event notification driver CLAXDROPE500

MBus IP Driver with 500 points CLAXDRMBSIP

Additional 500 MBus IP points CLAXDRMBSIP500

Skype service for AX Supervisor (full or SBS10) CLAXARENASKYPE

Fidelio Hotel booking system driver CLAXDRFIDELIO

SMS Driver for ARENA AX CLAXARENASMS

Database, CSV Server Driver CLAXDBCSV

Database, MS SQL Server Driver CLAXDBSQL

Database, Oracle Driver CLAXDBORCL

Database, DB2 Driver CLAXDBDB2

Database, MySQL Driver CLAXDBMYSQL

Database, Table Driver CLAXDBTBL

Axis Cameras video driver 16 Cameras CLAXARENAAXI

Additional 4 Cameras Axis video driver CLAXARENAAXI4

Dedicated Micros NetVu DVR video driver 16 Cameras CLAXARENADED

Additional 4 Cameras Dedicated Micros NetVu DVR video driver CLAXARENADED4

Milestone NVM video driver 16 Cameras CLAXARENAMIL

Additional 4 Cameras Milestone NVM video driver CLAXARENAMIL4

Upgrade of ARENA AX Small Building Supervisor to full ARENA AX CLAXARENASBSUP

Upgrade of ARENA AX and associated drivers, one revision CLAXARENARUP

Upgrade of ARENA AX and associated driver, to latest revision CLAXARENARUP2

Upgrade 32bit ARENA AX to 64 bit CLAXARENAW64UP

Upgrade CLAXARENASBS01 Small Building Supervisor 1 additional HAWK CLAXARENASBSU1

Page 75: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2-22

CentraLine Integration

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

ENERGY MANAGEMENT ESSENTIALS is a comprehensive and intuitive energy monitoring and targeting software, providing an impressive range of techniques for managing all aspects of energy related data.It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market providing more than 30 different protocols. ARENA supports the data exchange between LON, M-Bus and all the existing Honeywell installed base to the energy management suite. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.Features:

• Collect metering data• Monitor energy consumption• Analyze energy profiles• Detect waste of energy• Optimize energy efficiency• Translate raw energy values into monetary units• Plan energy consumption with budgets• Compare the real consumption against budgets• Report all the important data to energy managers• Dashboards to raise the awareness of building occupants

ENERGY MANAGEMENT ESSENTIALS supporting:

ENERGY MANAGEMENT ESSENTIALS

Product description Type25 meter points, 1 advanced user, 1 express user CLEMAN2550 meter points, 1 advanced user, 1 express user CLEMAN5075 meter points, 1 advanced user, 3 express user CLEMAN75

Page 76: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Configurable controllers Page

Stand alone controllers 3-2

Page 77: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-2

Stand alone controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Stand alone controllers

Microprocessor controller with fixed hard- and software. Configuration with 15 sets of parameters.For all Heating and District Heating applications with:

• direct heating circuit and/or mixed heating circuit(s)• boiler burner• domestic hot water• heat exchanger valve

Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: German, French, English, Dutch; 11 other display languages also supported

Wall mounting, HxWxD = 96x285x90 mm; Display languages and documentation: German, French, English, Dutch; 11 other display languages also supported

Heating, District Heating and Multi-Fuel OTC Controller, SMILE

Control software the software application can be selected, by keying in a planttype code, and can be adjusted with parameters; or use no code number and configure the application with the parametersets only

Modes of operations heating without time program, eco, summer, manu, auto

Clock functions heating with own week clock, DHW with own week clock, 15 vacation periods

Protection class IP30

Max. ambient temperature

50 oC

Power supply 230 Vac; 5,8 VA

Batteries included 3VLi

Bus system description • Honeywell bus sytem for max. 5 SMILE controllers, and 3 setpoint units per controller; max. buslength 100 m; the controller can also be used as stand-alone controller.

• OpenTherm for all models, except SDC3-40..

Hardware outputs all outputs are relay outputs with a maximum contact load of 2A 250V

• the standard relay outputs are for pumps and valves, and are controlled from the selected application; mixing valves need 2 output relays

• the function for the additional relay outputs can be set with parameters

Applicable sensor types NTC 20 kohm

Additional description One of the hardware inputs is for a pulse contact. This can be used for example for counting running hours. With parametersettings the amount of counted pulses can be used for switching pumps or boilers.

Burner output Heating circuit Domestic Hot Water Additional output Hardware inputs Type1 stage pump loading pump – 4 (1 var.) SDC3-10PM

– 1x: mixing valve + pump – – 4 (1 var.) SDC3-40PM1/2 stages 1x: mixing valve + pump; pump loading pump – 6 (SDC 1v DHC 3v) SDC7-21PM1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable 11 (3 var.) SDC9-21PM1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.) SDC12-31PM

Burner output Heating circuit Domestic Hot Water Additional output Hardware inputs Type1 stage pump loading pump – 4 (1 var.) SDC3-10WM

– 1x: mixing valve + pump – – 4 (1 var.) SDC3-40WM1/2 stages 1x: mixing valve + pump; pump loading pump – 6 (SDC 1v DHC 3v) SDC7-21WM1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable 11 (3 var.) SDC9-21WM1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.) SDC12-31WM

Page 78: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-3

Stand alone controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: Romanian, Russian, Polish, Hungarian, Czech, Turkish, English

Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: Italian, Spanish, Swedish, Norwegian; 11 other display languages also supported

Sensors

Remote setpoint selector with temperature sensor, night, day and auto switch

Comfortable digital remote setpoint selector with display, temperature sensor, access to the controller functions

Tamper proof covers for setpoint units

Mounting accessories for panel models

Burner output Heating circuit Domestic Hot Water Additional output Hardware inputs Type1 stage pump loading pump – 4 (1 var.) SDC3-10N

– 1x: mixing valve + pump – – 4 (1 var.) SDC3-40N1/2 stages 1x: mixing valve + pump; pump loading pump – 6 (SDC 1v DHC 3v) SDC7-21N1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable 11 (3 var.) SDC9-21N1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.) SDC12-31N

Burner output Heating circuit Domestic Hot Water Additional output Hardware inputs Type1 stage pump loading pump – 4 (1 var.) SDC3-10PMN

– 1x: mixing valve + pump – – 4 (1 var.) SDC3-40PMN1/2 stages 1x: mixing valve + pump; pump loading pump – 6 (SDC 1v DHC 3v) SDC7-21PMN1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.) SDC12-31PMN

Outdoor temperature sensor NTC AF20

Outdoor temperature sensor, NTC, strap on T7414C1012

Water temperature sensor, NTC, strap on pipe VF20A

Water temperature sensor, NTC, with well (135 mm) VF20T

Water temperature sensor, NTC, with well (300 mm) VF20L

Water temperature sensor NTC, cable type KTF20

Room temperature sensor NTC RF20

Tamperproof temperature sensor UK SDW10BCUK

Setpoint unit Western Europe SDW10WE

Setpoint unit Eastern Europe SDW10EE

Digital setpoint unit Western Europe SDW30

Digital setpoint unit Eastern Europe SDW30N

Cover for SDW10.. TG510A

Cover for SDW30.. TG511A

Connecting base for wall installation SWS-12

Base for touch protection SCS-12

Reducing frame for panel cut-out on controllers ZG52 /53 /55 / 82 /85 or ZG215 /215V /252 /254

SRR

Terminal block set for Smile controller (N-version), 10 sets TBS-SMILE

Single Terminal block set for Smile controller (N-Version) TBS-smile-1kit

Page 79: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-4

Stand alone controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Analogue controller.Applications:

• ZG252N: controller for 1 heating circuit

Accessories

Sensors and setpoint units

Main, outside temperature compensated controller heating

Hardware outputs relays

Modes of operations heating without time program, eco, manu, auto

Applicable sensor types NTC20 kohm

Clock functions not included, see accessories

Stand-alone operation yes

Materials ABS, UL-approved

Protection class IP50

Type of terminals screw terminals

Mounting wall and cabinet

Number of heating circuits 1

Heating/Ventilation application

heating

Setpoint device with wall modules

Power supply 230 Vac; 6 VA

Housing (HxWxD) 130 mm; 187 mm; 93 mm

Max. ambient temperature

45 oC

Control functions main temperature control, outside air compensation control

Hardware inputs 4 universal

Control output signal 3 relays

TypeZG252N

Analogue week or day timer for the heating circuit SU53-54

Remote setpoint selector with temperature sensor, day and auto switch TW20A

Page 80: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-5

Stand alone controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

Analogue controller.Applications:

• ZG215N: proportional cascade controller e.g. for room-flow-temperature cascade control with flow low limit

• ZG215VN: proportional fixed temperature controller with 3-position output

Accessories

Sensors and setpoint units

Main, fixed, room temperature controller heating/ventilating

Hardware outputs relays

Modes of operations heating without time program, eco, manu, auto

Applicable sensor types NTC20 kohm

Clock functions not included, see accessories

Stand-alone operation yes

Materials ABS, UL approved

Protection class IP50

Type of terminals screw terminals

Mounting wall and cabinet

Number of heating circuits 1

Heating/Ventilation application

heating + ventilating

Setpoint device with wall modules

Power supply 230 Vac; 6 VA

Housing (HxWxD) 130 mm; 187 mm; 93 mm

Max. ambient temperature

45 oC

Hardware inputs 3 universal

Control output signal 2 relays

Control functions Typemain- / room temperature control ZG215Nmain- / fixed temperature control ZG215VN

Analogue day or week timer for heating circuit SU53-54

Remote setpoint selector with temperature sensor, day and auto switch RF20A

Remote setpoint selector with temperature sensor, day, night and auto switch TF22

Remote setpoint selector with temperature sensor, night, day and auto switch, timer for up to 99 days

TFU22

Remote setpoint selector with temperature sensor, day and auto switch, room high limit

TW20A

Page 81: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-6

Stand alone controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The AQ3000 controller W6560C1005 is a configurable heating/cooling outdoor temperature compensated under-floor controller. Via a simple menu structure and the 5 buttons the control-ler can easily be configured according to the application specific settings.The controller has a number of control forms, which are depending on the configuration and the connected sensors. The standard heating control form is the OTC, where the supply water temperature is controlled according to a heat-ing curve with the outdoor temperature. The heat and cool requests (relay contacts) and the positioning of the mixing valve (open and close relay contacts) are both controlled.When a room sensor or thermostat is installed room com-pensation is added to the OTC control function. During cooling control the AQ3000 controller has the option to connect also a humidity sensor and to control a de-humidifier (relay contact).

Sensors

Digital temperature controller, LC-display, pushbuttons, setpoint potentiometer, and 1 control-output.For valve or damper control in air- or water temperature applications.

Accessories

Heat/Cool OTC underfloor controller

TypeW6560C1005

Outdoor temperature sensor NTC AF20

Water temperature sensor, NTC, strap on pipe VF20A

Water temperature sensor NTC, cable type KTF20

Room R.H.- and temperature sensor H7012B1023

Room temperature sensor T7412A1000

Temperature controller, 1 control output, Micronik200

Control output signal 2 triacs (24V~, 450mA) configurable for 2-pt, 3-pt, PWM or 2/3-stage control

Control functions main temperature control, limit control, cascade control, outside air compensation control

Main setpoint adjustment built in setpoint potentiometer, or external potentiometer

Modes of operations off, standby, comfort, summer/winter change-over, frost protection

Parameter settings temperature setpoints, throttling ranges, reset time, summer/winter compensation authority, sensor calibration etc.

Analogue input functions 3 inputs for: main-, limit/cascade-, and compensation temperature sensors

Applicable sensor types Pt1000, Balco500, NTC20k

Digital input functions frost protection with external contact

Special input functions occupancy- or summer/winter changeover contact and plant on/off input

Mounting back panel, wall, DIN-rail or front door (with additional mounting frame)

Protection class IP30, IP40 (front panel mounting)

Wiring connection screw terminals, max. 1 x 1,5 mm2

Power supply 24 Vac; 3 VA

Main temperature control range

0 ... 50 oC

Additional main temperature control range

0 ... 130 oC

Housing (HxWxD) 105 mm; 152 mm; 37 mm

TypeR7426A2006

Front panel mounting frame 43193862-001

Page 82: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-7

Stand alone controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

Digital temperature controller with real time clock, LC-display, pushbuttons, setpoint potentiometer, and 1 control-output.For valve or damper control in air- or water temperature applications.

Accessories

Temperature controller with clock, 1 control output, Micronik200

Control output signal 2 triacs (24V~, 450mA) configurable for 2-pt, 3-pt, PWM or 2/3-stage control

Plant output 1 on/off output (24V~) for plant, pump, fan etc.

Control functions main temperature control, limit control, cascade control, outside air compensation control

Main setpoint adjustment built in setpoint potentiometer, or external potentiometer

Modes of operations off, night, standby, comfort, optimum start, night cycle, summer/winter change-over, frost protection

Clock functions yearly real time clock with 3 holiday schedules, week program with 6 switching points/day; automatic daylight saving programs

Parameter settings temperature setpoints, throttling ranges, reset time, summer/winter compensation authority, sensor calibration etc.

Analogue input functions 3 inputs for: main-, limit/cascade-, and compensation temperature sensors

Applicable sensor types Pt1000, Balco500, NTC20k

Digital input functions frost protection with external contact

Special input functions occupancy- or summer/winter changeover contact

Mounting back panel, wall, DIN-rail or front door (with additional mounting frame)

Protection class IP30, IP40 (front panel mounting)

Wiring connection screw terminals, max. 1 x 1,5 mm2

Power supply 24 Vac; 3 VA

Main temperature control range

0 ... 50 oC

Additional main temperature control range

0 ... 130 oC

Housing (HxWxD) 105 mm; 152 mm; 37 mm

TypeR7426A2014

Front panel mounting frame 43193862-001

Page 83: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-8

Stand alone controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Digital temperature controller, LC-display, pushbuttons, setpoint potentiometer, and 3 control-outputs.For valve and damper control in space- and/or discharge air applications, with heating - mixed air/energy recovery - cooling sequence control

Accessories

Temperature controller, 3 control outputs, Micronik200

Control output signal Model B: 6 triacs (24V~, 450mA) configurable for 2-pt, 3-pt, PWM or 2/3/4/6/15-stage control; Model C: 3 x 0/2..10V= outputs

Control functions cascade, outside air compensation, sequence and dehumidification control

Main setpoint adjustment built in setpoint potentiometer, or external potentiometer

Modes of operations off, standby, comfort, economizer, frost protection

Parameter settings temperature setpoints, throttling ranges, reset time, summer/winter compensation authority, sensor calibration etc.

Analogue input functions 3 inputs for: main-, cascade- and compensation temperature sensors

Applicable sensor types Pt1000, Balco500, NTC20k

Digital input functions frost protection with external contact

Special input functions occupancy contact; humidity deviation signal; and plant on/off input

Mounting back panel, wall, DIN-rail or front door (with additional mounting frame)

Protection class IP30, IP40 (front panel mounting)

Wiring connection screw terminals, max. 1 x 1,5 mm2

Power supply 24 Vac; 3 VA

Main temperature control range

0 ... 50 oC

Housing (HxWxD) 105 mm; 152 mm; 37 mm

Control output Typetriac R7426B20040/2..10V= R7426C2002

Front panel mounting frame 43193862-001

Page 84: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-9

Stand alone controllers

2

3

4

5

6

7

8

10

9

11

12

13

14

Digital temperature controller with real time clock, LC-display, pushbuttons, setpoint potentiometer, and 3 control-outputs.For valve and damper control in space- and/or discharge air applications, with heating - mixed air/energy recovery - cooling sequence control

Accessories

Temperature controller with clock, 3 control outputs, Micronik200

Control output signal Model B: 6 triacs (24V~, 450mA) configurable for 2-pt, 3-pt, PWM or 2/3/4/6/15-stage control; Model C: 3 x 0/2..10V= outputs

Plant output 1 on/off output (24V~) for plant, pump, fan etc.

Control functions cascade, outside air compensation, sequence and dehumidification control

Main setpoint adjustment built in setpoint potentiometer, or external potentiometer

Modes of operations off, night, standby, comfort, optimum start, night cycle, economizer, frost protection

Clock functions yearly real time clock with 3 holiday schedules, week program with 6 switching points/day; automatic daylight saving programs

Parameter settings temperature setpoints, throttling ranges, reset time, summer/winter compensation authority, sensor calibration etc.

Analogue input functions 3 inputs for: main-, cascade- and compensation temperature sensors

Applicable sensor types Pt1000, Balco500, NTC20k

Digital input functions frost protection with external contact

Special input functions occupancy contact; humidity deviation signal

Mounting back panel, wall, DIN-rail or front door (with additional mounting frame)

Protection class IP30, IP40 (front panel mounting)

Wiring connection screw terminals, max. 1 x 1,5 mm2

Power supply 24 Vac; 3 VA

Main temperature control range

0 ... 50 oC

Additional main temperature control range

0 ... 130 oC

Housing (HxWxD) 105 mm; 152 mm; 37 mm

Control output Typetriac R7426B20120/2..10V= R7426C2010

Front panel mounting frame 43193862-001

Page 85: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

3-10

Stand alone controllers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Digital universal input controller with LC-display, pushbuttons, setpoint potentiometer, and 2 control-outputs.For space, discharge air humidity control applications, and special applications, e.g. pressure control.

Accessories

Universal input controller, 2 control outputs, Micronik200

Control output signal 0/2..10V= output and main value deviation signal

Plant output 1 on/off output (24V~) for plant, pump, fan etc.

Control functions PID main (temperature) control, limit control, cascade control, outside air compensation control

Main setpoint adjustment built in setpoint potentiometer, or external potentiometer

Parameter settings setpoints, throttling ranges, reset time, summer/winter compensation authority, sensor calibration etc.

Analogue input functions 2 inputs for: master and submaster or limit sensor

Applicable sensor types transmitters within the specified input ranges 0..10 V= or 0..20 mA

Digital input functions plant on/off with external contact or by controller with real time clock

Special input functions compensation temperature sensor, Pt1000, Balco500, NTC20k

Mounting back panel, wall, DIN-rail or front door (with additional mounting frame)

Protection class IP30, IP40 (front panel mounting)

Wiring connection screw terminals, max. 1 x 1,5 mm2

Power supply 24 Vac; 3 VA

Main control range 0 ... 100 %

Housing (HxWxD) 105 mm; 152 mm; 37 mm

TypeR7426D2000

Front panel mounting frame 43193862-001

Page 86: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Page

Small linear actuators, stroke 2,5/6,5mm 4-2Large linear actuators, stroke 20/38mm 4-7LON linear actuators 4-10Rotary valve actuators 4-11Damper actuators 4-13

Page 87: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-2

Small linear actuators, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Small linear actuators, stroke 2,5/6,5mm

Electrical actuator on/off control, and PWM control with XL10/12 controllers. For V58xxA/C (DN15/20), V90/V100 and VS valve series.MT4 models also suitable for TRV's V300, V2000, the Therafix TRV's V2464, V2474; and for the balancing valves V5010, V5032 (in combination with adapter VA2500A001).

2,5 mm; 90 N

6,5 mm; 90 N

Accessories

Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Protection class IP44

Position indication with red indicator

End switch function/capacity SPST, capacity 5(3) A; contact closes at power on

Stem force 90 N

Control input signal 2-pt

Additional description Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).

• Other adapters on request.• Other cable length, or special connectors, on request.• 24 Vac models also suitable for 24 Vdc.• Effective stroke for Honeywell valves 2,5/6,5 mm; maximum stroke

4/8 mm.• Fits to closing dimension 11,5 +/- 0,3 mm

Power supply Power loss action Stroke End switches Runtime Initial current Cable length TypeVac; VA mm min A m

24; 2 stem retracts 2,5 – 4 0,2 1 MT4-024-NO24; 2 stem retracts 2,5 – 4 0,2 2,5 MT4-024-NO-2.5M24; 2 stem retracts 2,5 1 4 0,2 1 MT4-024S-NO24; 2 stem extends 2,5 – 4 0,2 1 MT4-024-NC24; 2 stem extends 2,5 – 4 0,2 2,5 MT4-024-NC-2.5M24; 2 stem extends 2,5 1 4 0,2 1 MT4-024S-NC

230; 2 stem retracts 2,5 – 4 0,4 1 MT4-230-NO230; 2 stem retracts 2,5 – 4 0,4 2,5 MT4-230-NO-2.5M230; 2 stem retracts 2,5 1 4 0,4 1 MT4-230S-NO230; 2 stem extends 2,5 – 4 0,4 1 MT4-230-NC230; 2 stem extends 2,5 – 4 0,4 2,5 MT4-230-NC-2.5M230; 2 stem extends 2,5 1 4 0,4 1 MT4-230S-NC

Power supply Power loss action Stroke End switches Runtime Initial current Cable length TypeVac; VA mm min A m

24; 2 stem retracts 6,5 – 6 0,2 1 MT8-024-NO24; 2 stem retracts 6,5 – 6 0,2 2,5 MT8-024-NO-2.5M24; 2 stem retracts 6,5 1 6 0,2 1 MT8-024S-NO24; 2 stem extends 6,5 – 6 0,2 1 MT8-024-NC24; 2 stem extends 6,5 – 6 0,2 2,5 MT8-024-NC-2.5M24; 2 stem extends 6,5 1 6 0,2 1 MT8-024S-NC

230; 2 stem retracts 6,5 – 6,5 0,4 1 MT8-230-NO230; 2 stem retracts 6,5 – 6,5 0,4 2,5 MT8-230-NO-2.5M230; 2 stem retracts 6,5 1 6,5 0,4 1 MT8-230S-NO230; 2 stem extends 6,5 – 6,5 0,4 1 MT8-230-NC230; 2 stem extends 6,5 – 6,5 0,4 2,5 MT8-230-NC-2.5M230; 2 stem extends 6,5 1 6,5 0,4 1 MT8-230S-NC

Extra mounting clips; 10 units MT-CLIP

Page 88: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-3

Small linear actuators, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Plug-in cable (not for models with end switch)

Adapters

Electrical actuator for valve series: V58xxA/C (DN15-20), V90, V100, V300, V2000, V2464, V2474, VSO. For thermostatic radiator valves with connection size: M30 x 1,5.

2,5 mm; 90 N

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.

2,5 mm; 90 N

Accessories

Cable 1,5 meter; 10 units MT-CABLE-1.5M

Cable 2,5 meter; 10 units MT-CABLE-2.5M

Cable 5 meter; 10 units MT-CABLE-5M

Cable 10 meter; 10 units MT-CABLE-10M

Extra mounting adapters M30 x 1,5; 10 units MT-ADAPT-HW

Mounting adapter for Herz/Polytherm valves; 10 units MT-ADAPT-HP

Danfoss-RA adapter; 10 units EVA10RA

Mounting adapter for Velta -Compact Manifold HCA1VEL

Mounting adapter for Giacomini; 5 units R453HY002

Actuator thermoelectric 0..10V for terminal unit/radiator valves, 2,5 mm 90 N, MT010

Protection class IP54

Stem force 90 N

Power supply 24 Vac; 2 VA

Control input signal 0..10V=

Stroke 2,5 mm

Power loss action stem extends

Runtime 75 s

Initial current 0,25 A

Additional description Effective stroke for Honeywell valves 2,5 mm; maximum stroke 3,5 mm.

Cable length Typem

1 MT010-N3 MT010-3MN

Actuator 3-pt for terminal unit/radiator valves, 2,5 mm 90 N, M7410A

Protection class IP43

Position indication with red indicator

Stem force 90 N

Power supply 24 Vac; 0,7 VA

Control input signal 3-pt

Stroke 2,5 mm

Runtime 57 s

Cable length 0,9 m

Additional description Manual operation with valve cap.

TypeM7410A1001

Adapter for Danfoss RA2000 IRA-AD

Page 89: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-4

Small linear actuators, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Electrical actuator on/off control, for valve series VS, V58.. DN15/20 and V100/V2000 TRV-series.

6,5 mm; 90 N

Electrical actuator floating control.

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM

Fast motoric actuator for terminal unit/radiator valves, 6,5 mm 90 N, M5410

Protection class IP54

Stem force 90 N

Control input signal 2-pt

Stroke 6,5 mm

Power loss action stem retracts

Runtime 3,6/16 s

Cable length 1,5 m

Additional description Manual operation with valve cap.

Power supply TypeVac; VA

24; 8 M5410C1001230; 15 M5410L1001

Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Protection class IP43/IP42

Position indication with red indicator

End switch function/capacity SPDT; capacity 1 A inductive, 5 A resistive

Control input signal 3-pt

Stroke 6,5 mm

Runtime 150 s

Cable length 1,5 m

Additional description For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.

Stem force Power supply Manual operation End switches TypeN Vac; VA

180 24; 0,7 – – M7410C1007180 24; 0,7 • – M6410C2023180 24; 0,7 • 2 M6410C4029180 230; 7 • – M6410L2023180 230; 7 • 2 M6410L4029

Page 90: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-5

Small linear actuators, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2

Accessories

Electrical actuator modulating control.

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2

Accessories

Stem force Power supply Manual operation End switches TypeN Vac; VA

300 24; 0,7 – – M7410C1015300 24; 0,7 • – M6410C2031300 24; 0,7 • 2 M6410C4037300 230; 7 • – M6410L2031300 230; 7 • 2 M6410L4037

Adapter for valve series V5077B/V5078B 0903403

Actuator 0/2..10V for zone control, 6,5 mm 180/300 N, M7410E

Protection class IP42

Position indication with red indicator

End switch function/capacity SPDT, capacity 1A inductive, 5A resistive

Power supply 24 Vac; 1,4 VA

Control input signal 0/2..10V=

Stroke 6,5 mm

Runtime 150 s

Cable length 1,5 m

Additional description The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.

Stem force Manual operation End switches TypeN

180 – – M7410E1002180 • – M7410E2026180 • 2 M7410E4022

Stem force Manual operation End switches TypeN

300 – – M7410E1028300 • – M7410E2034300 • 2 M7410E4030

Adapter for valve series V5077B/V5078B 0903403

Page 91: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-6

Small linear actuators, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40).

6,5 mm; 400 N

Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)

6,5 mm; 400 N

Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435

Protection class IP54

Stem force 400 N

Control input signal 0/2..10V=

Stroke 6,5 mm

Additional description For ML7435E1004: approved according DIN EN 14597 in combination with V5825B.

Power supply Power loss action Manual operation Runtime Spring return TypeVac; VA s

24; 5 – • 15 – ML7430E100524; 10 stem retracts – 60 • ML7435E1004

Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435

Protection class IP54

Stem force 400 N

Control input signal 3-pt

Stroke 6,5 mm

Power loss action stem retracts

Runtime 60 s

Spring return yes

Additional description Approved according DIN EN 14597 in combination with V5825B.

Power supply TypeVac; VA

24; 10 ML6435B1008230; 10 ML6435B1016

Page 92: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-7

Large linear actuators, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Large linear actuators, stroke 20/38mm

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.

20 mm; 600 N

20 mm; 600 N, Spring return

Accessories

High temperature kits for:

Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Protection class IP54

Position indication scale plate

Position feedback optional

End switches optional

Stem force 600 N

Control input signal 3-pt

Stroke 20 mm

Additional description For ML6425-models: approved according DIN EN 14597 in combination with V5016A/V5025A/V5328A/V5049A.

Power supply Power loss action Manual operation Runtime Spring return TypeVac; VA min

24; 4 – • 1,0 – ML6420A300724; 4 – – 1,0 – ML6420A307224; 6 – • 0,5 – ML6420A3023

230; 6,5 – • 1,0 – ML6420A3015230; 6,5 – • 0,5 – ML6420A3031

Power supply Power loss action Manual operation Runtime Spring return TypeVac; VA min

24; 11 stem extends • 1,8 • ML6425A300624; 11 stem retracts • 1,8 • ML6425B3005

230; 12 stem extends • 1,8 • ML6425A3014230; 12 stem retracts • 1,8 • ML6425B3021

Dual end switches SPDT, adjustable (250 V~, 10 A) 43191680-005

Feedback potentiometer 10 kohm, operating range 43191679-011

Feedback potentiometer 220 ohm operating range 43191679-012

V5011R/S, V5013R/E; V5328A/V5329A DN15..32 43196000-001

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80

43196000-002

Page 93: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-8

Large linear actuators, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.

20 mm; 600 N

20 mm; 600 N, Spring return

Accessories

High temperature kits for:

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.

20 mm; 1800 N

Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Protection class IP54

Position indication scale plate

Stem position at control signal loss

adjustable

End switches optional

Stem force 600 N

Stroke 20 mm

Additional description The control action is reversable. For ML7425-models: approved according DIN EN 14597 in combination with V5016A/V5025A/V5328A/V5049A.

Powersupply

Control inputsignal

Power lossaction

Manualoperation

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

24; 5 0/2..10V= – • 1,0 – 2..10V= ML7420A600924; 5 2..10V= – – 1,0 – – ML7420A602524; 7 0/2..10V= – • 0,5 – 2..10V= ML7420A6017

Powersupply

Control inputsignal

Power lossaction

Manualoperation

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

24; 12 0/2..10V= stem extends • 1,8 • 2..10V= ML7425A600824; 12 0/2..10V= stem retracts • 1,8 • 2..10V= ML7425B6007

Auxiliary switch (250 V~, 10 A) 43191680-205

V5011R/S, V5013R/E; V5328A/V5329A DN15..32 43196000-001

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80

43196000-002

Actuator 3-pt, 20/38 mm 1800 N, ML6421

Protection class IP54

Position indication scale plate on the yoke

End switches optional

Stem force 1800 N

Control input signal 3-pt

Manual operation yes

Power supply Stroke Runtime Position feedback TypeVac; VA mm min

24; 13 20 1,9 optional ML6421A3005230; 11 20 1,9 – ML6421A3013

Page 94: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-9

Large linear actuators, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

38 mm; 1800 N

Accessories

High temperature kits for:

Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.

20 mm; 1800 N

38 mm; 1800 N

Accessories

High temperature kits for:

Power supply Stroke Runtime Position feedback TypeVac; VA mm min

24; 13 38 3,5 optional ML6421B3004230; 11 38 3,5 – ML6421B3012

Dual end switches SPDT, adjustable (250 V~, 10 A) 43191680-002

Single feedback potentiometer 220/135 ohm operating range, for 20 mm models 43191679-001

Single feedback potentiometer 10 kohm operating range, for 20 mm models 43191679-007

Single feedback potentiometer 220/135 ohm operating range, for 38 mm models 43191679-002

Single feedback potentiometer 10 kohm operating range, for 38 mm models 43191679-008

V5011R/S, V5013R/E; V5328A/V5329A DN15..32 43196000-001

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80

43196000-002

V5015A/V5016A/V5025A/V5049A/V5050A/B/V5328A 38 mm 43196000-038

Actuator 0/2..10V, 20/38 mm 1800 N, ML7421

Protection class IP54

Position indication scale plate

Stem position at control signal loss

selectable: closed, half open, open

Position feedback 2..10V=

End switches optional

Stem force 1800 N

Power supply 24 Vac; 12 VA

Control input signal 0/2..10V=; 0/4..20mA

Manual operation yes

Stroke Runtime Typemm min

20 1,9 ML7421A3004

Stroke Runtime Typemm min

38 3,5 ML7421B3003

Dual end switches SPDT, adjustable (250 V~, 10 A) 43191680-002

V5011R/S, V5013R/E; V5328A/V5329A DN15..32 43196000-001

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80

43196000-002

V5015A/V5016A/V5025A/V5049A/V5050A/B/V5328A 38 mm 43196000-038

Page 95: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-10

LON linear actuators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

LON linear actuators

Electrical actuator with LON input signal.

2,5 mm; 90 N; for valve series: V100 (thermostatic valves), V58..A4, V58..C4, VSO

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2

LON actuator for radiator valves/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Protection class IP42

Position indication with red indicator

LonMark(R) profile input SNVT percent 0-100%

Transceiver type FTT 10A

Power supply 24 Vac; 1,4 VA

Control input signal LON

Cable length 1,5 m

Additional description Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.

Stem force Stroke Runtime TypeN mm s

90 2,5 53 M7410G1008

Stem force Stroke Runtime TypeN mm s

180 6,5 150 M7410G1016

Stem force Stroke Runtime TypeN mm s

300 6,5 150 M7410G1024

Page 96: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-11

Rotary valve actuators

2

3

4

5

6

7

8

10

9

11

12

13

14

Rotary valve actuators

Electrical actuator for valve series V5433A/G, V5442A/G.

Electrical actuator for valve series V5421, DRG, ZR.

Floating control

Compact Line Rotary Valve Actuator

Protection class IP44

End switch function/capacity SPST; capacity 1A inductive, 3 A resistive

Torque 7 Nm

Control input signal 3-pt

Angle of rotation 90 o

Manual operation yes

Runtime 100 s

Cable length 1,5 m

Additional description Manual operation by declutch of gear.

Power supply End switches TypeVac; VA

24; 3 – M6063A100324; 3 2 M6063A4007

230; 3 – M6063L1009230; 3 2 M6063L4003

Linkage of M6063L as replacement for M676A,C 075041061

Standard Line Rotary Valve Actuator

Protection class IP54

Position indication reversable scale plate

Angle of rotation 90 o

Manual operation yes

Additional description Manual operation by declutch of gear.

Torque Power supply Control input signal Runtime Position feedback End switches TypeNm Vac; VA min

10 24; 3,5 3-pt 1,5 – optional M6061A101320 24; 3,5 3-pt 1,6 – optional M6061A102130 24; 3,5 3-pt 2,3 – optional M6061A103940 24; 3,5 3-pt 3,5 – optional M6061A104710 230; 3,5 3-pt 1,5 – optional M6061L101920 230; 3,5 3-pt 1,6 – optional M6061L102730 230; 3,5 3-pt 2,3 optional optional M6061L103540 230; 3,5 3-pt 3,5 – optional M6061L1043

Page 97: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-12

Rotary valve actuators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Modulating control

Accessories for floating control motors

Accessories for modulating control motors

Optional accessories

Torque Power supply Control input signal Runtime Position feedback End switches TypeNm Vac; VA min

10 24; 2,4 0/2..10V= 1,5 optional – M7061E101220 24; 2,4 0/2..10V= 3,0 optional – M7061E1020

Feedback potentiometer 10 kohm, only for M6061L1035 VMP10-90

Auxiliary switch package VMS2

Feedbacksignal of position 0..10 V VMU1

Actuator for butterfly valve V5421B1090

Protection class IP54

Power supply 230 Vac; 7 VA

Control input signal 3-pt

Built in rotation limiter no

Manual operation yes

End switches optional

Runtime 150 s

Torque 40 Nm

TypeM6422L1003

End switch AS2

Page 98: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-13

Damper actuators

2

3

4

5

6

7

8

10

9

11

12

13

14

Damper actuators

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.

For damper area of 1 square meter

For damper area of 2 square meters

Damper actuator 5/10 Nm, SmartAct

Protection class IP54

End switch function/capacity SPDT switch 230 V, 5(3) A for models with end switch

Shaft mounting for round shafts 8..16 mm; square shafts 6..13 mm

Built in rotation limiter yes

Manual operation yes

Position feedback optional

Additional description • removable wiring box for direct wiring to and from controller• rotation direction selectable by switch• adjustable mechanical end limits included• 24 Vac models also suitable for 24 Vdc

Power supply Control input signal End switches Runtime Torque Damper area TypeVac; VA s;50Hz Nm m2

24; 6 2/3-pt – 110 5 1 N052424; 6 2/3-pt 2 110 5 1 N0524-SW2

230; 6 2-pt – max. 110 5 1 N05230-2POS24; 6 0/2..10V=;2/3-pt – 90/110 5 1 N0501024; 6 0/2..10V=;2/3-pt 2 90/110 5 1 N05010-SW2

Power supply Control input signal End switches Runtime Torque Damper area TypeVac; VA s;50Hz Nm m2

24; 6 2/3-pt – 110 10 2 N102424; 6 2/3-pt 2 110 10 2 N1024-SW2

230; 6 2-pt – max. 140 10 2 N10230-2POS24; 6 0/2..10V=;2/3-pt – 90/110 10 2 N1001024; 6 0/2..10V=;2/3-pt 2 90/110 10 2 N10010-SW2

Page 99: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-14

Damper actuators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Direct-coupled actuator with self-centering shaft adapter. For air dampers, air handlers, ventilation flaps, louvers and VAV-units.

For damper area of 4 square meters

For damper area of 6 square meters

Optional accessories

Damper actuator 20/34 Nm, SmartAct

Protection class IP54

Position indication rotational angle scales 0..90o, 90..0o

End switch function/capacity SPDT switch 230V, 5 (3) A for models with end switch

Shaft mounting for round shafts 10..27 mm; square shafts 10..18 mm

Manual operation yes

Additional description • Rotation direction selectable by switch.• When power is removed, the actuator remains in position.• Removable wiring box.• Actuator supplied with complete package mounting parts.• For modulating control models: Control input signal can be voltage

or current.• For modulating control models: Autoadapt dipswitch. With this

function the full span of the control input signal will be used for the applicable angle or rotation.

Powersupply

Control inputsignal

Built in rotationlimiter

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s Nm m2

24; 6 2/3-pt • optional – 110 20 4 N2024A24; 6 2/3-pt • 2 – 110 20 4 N2024A-SW2

230; 6 2/3-pt • optional – 110 20 4 N20230A230; 6 2/3-pt • 2 – 110 20 4 N20230A-SW2

24; 6 0/2..10V= • optional 0/2..10V= 95 20 4 N20010A24; 6 0/2..10V= • 2 0/2..10V= 95 20 4 N20010A-SW2

Powersupply

Control inputsignal

Built in rotationlimiter

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s Nm m2

24; 7 2/3-pt – optional – 110 34 6 N3424A230; 7 2/3-pt – optional – 110 34 6 N34230A

24; 8 0/2..10V= – optional 0/2..10V= 95 34 6 N34010A

End switch kit, with 2 SPDT freely adjustable end-switches SW2

Page 100: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-15

Damper actuators

2

3

4

5

6

7

8

10

9

11

12

13

14

Direct-coupled actuator with self-centering shaft adapter. For the operation of quarter-turn air dampers in safety related applications requiring springreturn fail-safe operation (e.g. frost protection).

Damper actuator 3/5 Nm, SmartAct springreturn

Protection class IP54

Position indication rotational angle scales 0..90o, 90..0o

End switch function/capacity models with 1 SPDT switch 250 V, 8 (5) A; adjustable setting between 0o and 95o

Shaft mounting for round shafts 9..16 mm; square shafts 6..13 mm

Spring return yes

Manual operation no

Spring return timing 25 s

Additional description • Rotation direction selectable by flipping the actuator 180o around its vertical axis.

• Actuator supplied with complete package mounting parts.• Actuators come with detachable wiring box.• Durable plastic housing with built-in mechanical end-limits.

Powersupply

Control inputsignal

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s;50Hz Nm m2

24; 7 2-pt – – 45 3 0,6 S0324-2POS24; 7 2-pt 1 – 45 3 0,6 S0324-2POS-SW1

230; 13 2-pt – – 45 3 0,6 S03230-2POS230; 13 2-pt 1 – 45 3 0,6 S03230-2POS-SW1

24; 7 0/2..10V=;3-pt – 0..10V= 90 3 0,6 S0301024; 7 0/2..10V=;3-pt 1 0..10V= 90 3 0,6 S03010-SW1

Powersupply

Control inputsignal

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s;50Hz Nm m2

24; 8 2-pt – – 45 5 1 S0524-2POS24; 8 2-pt 1 – 45 5 1 S0524-2POS-SW1

230; 14 2-pt – – 45 5 1 S05230-2POS230; 14 2-pt 1 – 45 5 1 S05230-2POS-SW1

24; 8 0/2..10V=;3-pt – 0..10V= 90 5 1 S0501024; 8 0/2..10V=;3-pt 1 0..10V= 90 5 1 S05010-SW1

Page 101: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

4-16

Damper actuators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Direct-coupled actuator with self-centering shaft adapter. For the operation of quarter-turn air dampers in safety related applications requiring springreturn fail-safe operation (e.g. frost protection).

Optional accessories

Damper actuator 10/20 Nm, SmartAct springreturn

Protection class IP54

Position indication rotational angle scales 0..90o, 90..0o

End switch function/capacity models with 2 SPDT switches 250 V, 3 (1,5) A; fixed setting at 7o and 85o

Shaft mounting for round shafts 10..27 mm; square shafts 13..19 mm

Spring return yes

Manual operation yes

Spring return timing 20 s

Additional description • Rotation direction selectable by flipping the actuator 180o around its vertical axis.

• Actuator supplied with complete package mounting parts.• Autoadapt dipswitch. With this function the full span of the control

input signal will be used for the applicable angle or rotation.• Actuators come with detachable wiring box.• Actuator can be locked and manually wound.

Powersupply

Control inputsignal

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s;50Hz Nm m2

24; 8/30 2-pt optional – 45 10 1,5 S1024-2POS24; 8/30 2-pt 2 – 45 10 1,5 S1024-2POS-SW2

230; 13/45 2-pt optional – 45 10 1,5 S10230-2POS230; 13/45 2-pt 2 – 45 10 1,5 S10230-2POS-SW2

24; 5/14 0/2..10V=;3-pt optional 0..10V= 90 10 1,5 S1001024; 5/14 0/2..10V=;3-pt 2 0..10V= 90 10 1,5 S10010-SW2

Powersupply

Control inputsignal

Endswitches

Positionfeedback

Runtime Torque Damperarea

Type

Vac; VA s;50Hz Nm m2

24; 8/40 2-pt optional – 45 20 4,6 S2024-2POS24; 8/40 2-pt 2 – 45 20 4,6 S2024-2POS-SW2

230; 13/60 2-pt optional – 45 20 4,6 S20230-2POS230; 13/60 2-pt 2 – 45 20 4,6 S20230-2POS-SW2

24; 5/16 0/2..10V=;3-pt optional 0..10V= 90 20 4,6 S2001024; 5/16 0/2..10V=;3-pt 2 0..10V= 90 20 4,6 S20010-SW2

End switch kit, with 2 SPDT freely adjustable end-switches SW2

Page 102: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Valves linear Page

2-way linear valves, stroke 2,5/6,5mm 5-22-way linear valves, stroke 20/38mm 5-143-way linear valves, stroke 2,5/6,5mm 5-243-way linear valves, stroke 20/38mm 5-42

Page 103: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-2

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

2-way linear valves, stroke 2,5/6,5mm

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open

Accessories

Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2

Valve type 2-way

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOC-215-1.015 G1/2 1 600 – 2,5 on/off • VSOC-215-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOC-215-1.615 G1/2 1,6 300 – 2,5 on/off • VSOC-215-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOC-215-2.515 G1/2 2,5 150 – 2,5 on/off • VSOC-215-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOC-220-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOC-220-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOC-220-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOC-220-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOC-225-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOC-225-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,16 600 600 6,5 mod.equal% – VSMC-215-0.1615 G1/2 0,25 600 600 6,5 mod.equal% – VSMC-215-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMC-215-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMC-215-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMC-215-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMC-215-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMC-215-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMC-220-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMC-220-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMC-220-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMC-220-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMC-225-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMC-225-8.0P

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size R3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size R1/2" ACN-20T

External threaded fitting for DN25 valve, pipe size R1" ACN-25T

Page 104: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-3

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 valve open – – 75 s 1 MT010-N0..10V= 24; 2 valve open – – 75 s 3 MT010-3MN

2-pt 24; 2 valve open – – 4 min 1 MT4-024-NC2-pt 24; 2 valve open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 valve open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 valve closed – – 4 min 1 MT4-024-NO2-pt 24; 2 valve closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 valve closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 valve open – – 4 min 1 MT4-230-NC2-pt 230; 2 valve open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 valve open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 valve closed – – 4 min 1 MT4-230-NO2-pt 230; 2 valve closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 valve closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 valve open – – 6 min 1 MT8-024-NC2-pt 24; 2 valve open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 valve open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 valve closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 valve closed – – 6 min 1 MT8-024-NO2-pt 24; 2 valve closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 valve closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 valve open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 valve open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 valve open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 valve closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 valve closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 valve closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 valve closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 105: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-4

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open

Accessories

Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2

Valve type 2-way

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOF-215-1.015 G1/2 1 600 – 2,5 on/off • VSOF-215-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOF-215-1.615 G1/2 1,6 300 – 2,5 on/off • VSOF-215-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOF-215-2.515 G1/2 2,5 150 – 2,5 on/off • VSOF-215-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOF-220-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOF-220-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOF-220-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOF-220-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOF-225-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOF-225-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,16 600 600 6,5 mod.equal% – VSMF-215-0.1615 G1/2 0,25 600 600 6,5 mod.equal% – VSMF-215-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMF-215-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMF-215-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMF-215-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMF-215-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMF-215-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMF-220-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMF-220-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMF-220-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMF-220-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMF-225-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMF-225-8.0P

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size R3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size R1/2" AC-20FT

External threaded fitting for DN25 valve, pipe size R1" ACS-25T

Page 106: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-5

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 valve open – – 75 s 1 MT010-N0..10V= 24; 2 valve open – – 75 s 3 MT010-3MN

2-pt 24; 2 valve open – – 4 min 1 MT4-024-NC2-pt 24; 2 valve open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 valve open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 valve closed – – 4 min 1 MT4-024-NO2-pt 24; 2 valve closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 valve closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 valve open – – 4 min 1 MT4-230-NC2-pt 230; 2 valve open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 valve open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 valve closed – – 4 min 1 MT4-230-NO2-pt 230; 2 valve closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 valve closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 valve open – – 6 min 1 MT8-024-NC2-pt 24; 2 valve open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 valve open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 valve closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 valve closed – – 6 min 1 MT8-024-NO2-pt 24; 2 valve closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 valve closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 valve open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 valve open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 valve open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 valve closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 valve closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 valve closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 valve closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 107: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-6

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Two-way control valve PN16, conical sealing DN15/20, V5822A

Valve series V5822A

Valve type 2-way

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem up

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap (not for on/off types).

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 180 – 2,5 on/off V5822A400020 1 1/8" x 14 2,5 50 – 2,5 on/off V5822A4018

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,16 600 1600 6,5 mod.equal% V5822A100615 G1/2 0,25 600 1600 6,5 mod.equal% V5822A101415 G1/2 0,4 600 1600 6,5 mod.equal% V5822A102215 G1/2 0,63 600 1600 6,5 mod.equal% V5822A103015 G1/2 1 180 1200 6,5 mod.equal% V5822A104815 G1/2 1,6 180 1200 6,5 mod.equal% V5822A105520 1 1/8" x 14 2,5 50 400 6,5 mod.equal% V5822A106320 1 1/8" x 14 4 50 400 6,5 mod.equal% V5822A1071

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size 3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size 1/2" ACN-20T

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 108: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-7

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 valve closed – – 75 s 1 MT010-N0..10V= 24; 2 valve closed – – 75 s 3 MT010-3MN

2-pt 24; 2 valve open – – 4 min 1 MT4-024-NO2-pt 24; 2 valve open – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 valve open – 1 4 min 1 MT4-024S-NO2-pt 24; 2 valve closed – – 4 min 1 MT4-024-NC2-pt 24; 2 valve closed – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 valve closed – 1 4 min 1 MT4-024S-NC2-pt 230; 2 valve open – – 4 min 1 MT4-230-NO2-pt 230; 2 valve open – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 valve open – 1 4 min 1 MT4-230S-NO2-pt 230; 2 valve closed – – 4 min 1 MT4-230-NC2-pt 230; 2 valve closed – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 valve closed – 1 4 min 1 MT4-230S-NC3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 8 valve open – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 valve open – – 6 min 1 MT8-024-NO2-pt 24; 2 valve open – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 valve open – 1 6 min 1 MT8-024S-NO2-pt 24; 2 valve closed – – 6 min 1 MT8-024-NC2-pt 24; 2 valve closed – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 valve closed – 1 6 min 1 MT8-024S-NC2-pt 230; 15 valve open – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 valve open – – 6,5 min 1 MT8-230-NO2-pt 230; 2 valve open – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 valve open – 1 6,5 min 1 MT8-230S-NO2-pt 230; 2 valve closed – – 6,5 min 1 MT8-230-NC2-pt 230; 2 valve closed – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 valve closed – 1 6,5 min 1 MT8-230S-NC

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 109: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-8

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Two-way control valve PN16, flat sealing DN15/20, V5832A

Valve series V5832A

Valve type 2-way

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem up

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap (not for on/off types).

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 180 – 2,5 on/off V5832A400820 G3/4 2,5 50 – 2,5 on/off V5832A4016

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,16 600 1600 6,5 mod.equal% V5832A100415 G1/2 0,25 600 1600 6,5 mod.equal% V5832A101215 G1/2 0,4 600 1600 6,5 mod.equal% V5832A102015 G1/2 0,63 600 1600 6,5 mod.equal% V5832A103815 G1/2 1 180 1200 6,5 mod.equal% V5832A104615 G1/2 1,6 180 1200 6,5 mod.equal% V5832A105320 G3/4 2,5 50 400 6,5 mod.equal% V5832A106120 G3/4 4 50 400 6,5 mod.equal% V5832A1079

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size 3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size 1/2" AC-20FT

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 110: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-9

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 valve closed – – 75 s 1 MT010-N0..10V= 24; 2 valve closed – – 75 s 3 MT010-3MN

2-pt 24; 2 valve open – – 4 min 1 MT4-024-NO2-pt 24; 2 valve open – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 valve open – 1 4 min 1 MT4-024S-NO2-pt 24; 2 valve closed – – 4 min 1 MT4-024-NC2-pt 24; 2 valve closed – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 valve closed – 1 4 min 1 MT4-024S-NC2-pt 230; 2 valve open – – 4 min 1 MT4-230-NO2-pt 230; 2 valve open – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 valve open – 1 4 min 1 MT4-230S-NO2-pt 230; 2 valve closed – – 4 min 1 MT4-230-NC2-pt 230; 2 valve closed – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 valve closed – 1 4 min 1 MT4-230S-NC3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 8 valve open – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 valve open – – 6 min 1 MT8-024-NO2-pt 24; 2 valve open – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 valve open – 1 6 min 1 MT8-024S-NO2-pt 24; 2 valve closed – – 6 min 1 MT8-024-NC2-pt 24; 2 valve closed – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 valve closed – 1 6 min 1 MT8-024S-NC2-pt 230; 15 valve open – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 valve open – – 6,5 min 1 MT8-230-NO2-pt 230; 2 valve open – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 valve open – 1 6,5 min 1 MT8-230S-NO2-pt 230; 2 valve closed – – 6,5 min 1 MT8-230-NC2-pt 230; 2 valve closed – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 valve closed – 1 6,5 min 1 MT8-230S-NC

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 111: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-10

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pressure balanced control valve.For fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

6,5 mm

Accessories

Two-way control valve PN16, flat sealing DN25-40, V5832B

Valve series V5832B2

Valve type 2-way press. bal.

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Stroke 6,5 mm

Media temp. 2 ... 130 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Flow char. linear

Additional description Valves are supplied with adjustment cap.

DN size Connectiondiameter

Kvs value Close off pressurewith 300N motor

Close off pressurewith 400N motor

Type

mm inch kPa kPa

25 G1 1/2 4 1600 1600 V5832B207525 G1 1/2 6,3 1600 1600 V5832B208325 G1 1/2 10 1600 1600 V5832B209132 G2 16 1200 1200 V5832B210940 G2 1/4 25 1000 1000 V5832B2117

External threaded fitting for DN25 valve, pipe size R1" AC-25T

External threaded fitting for DN32 valve, pipe size R11/4" AC-32T

External threaded fitting for DN40 valve, pipe size R11/2" AC-40T

Internal threaded fitting for DN25 valve, pipe size Rp1" AC-25TF

Internal threaded fitting for DN32 valve, pipe size Rp11/4" AC-32TF

Internal threaded fitting for DN40 valve, pipe size Rp11/2" AC-40TF

Page 112: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-11

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Springreturn

Type

Vac; VA s m

6,5 mm; 300 N 0/2..10V= 24; 1,4 – – – 150 1,5 – M7410E10280/2..10V= 24; 1,4 – • – 150 1,5 – M7410E20340/2..10V= 24; 1,4 – • 2 150 1,5 – M7410E4030

3-pt 24; 0,7 – – – 150 1,5 – M7410C10153-pt 24; 0,7 – • – 150 1,5 – M6410C20313-pt 24; 0,7 – • 2 150 1,5 – M6410C40373-pt 230; 7 – • – 150 1,5 – M6410L20313-pt 230; 7 – • 2 150 1,5 – M6410L4037LON 24; 1,4 – – – 150 1,5 – M7410G1024

6,5 mm; 400 N 0/2..10V= 24; 5 – • – 15 – – ML7430E10050/2..10V= 24; 10 valve closed – – 60 – • ML7435E1004

3-pt 24; 10 valve closed – – 60 – • ML6435B10083-pt 230; 10 valve closed – – 60 – • ML6435B1016

Page 113: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-12

2-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Compact district heating valve, with wide application range.For domestic hot water and district heating; hot water or cold water (max. 50% glycol), water quality VDI2035.

6,5 mm

Accessories

Adapter kits for in case V5872B models must be replaced with V5825B models

Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B

Valve series V5825B

Valve type 2-way press. bal.

Medium type water/steam

Materials body red bronze (DIN1705), trim stainless steel

Action to open stem down

Close off pressure with 300N motor

1600 kPa

Close off pressure with 400N motor

2500 kPa

Stroke 6,5 mm

Media temp. 2 ... 130 oC

Pressure rating PN25

Port connection ext. thread flat sealing

Flow char. mod.equal%

Additional description Approved according DIN EN 14597 in combination with ML7435E/ML6435B.

DN size Connection diameter Kvs value Typemm inch

15 G3/4 0,25 V5825B100115 G3/4 0,4 V5825B101915 G3/4 0,63 V5825B102715 G3/4 1 V5825B103515 G3/4 1,6 V5825B104320 G1 2,5 V5825B105020 G1 4 V5825B106825 G1 1/4 6,3 V5825B107632 G1 1/2 10 V5825B1084

External threaded fitting for DN15 valve, pipe size R1/2" ACS-15T

External threaded fitting for DN20 valve, pipe size R3/4" ACS-20T

External threaded fitting for DN25 valve, pipe size R1" ACS-25T

External threaded fitting for DN32 valve, pipe size R1 1/4" ACS-32T

Welding fitting for DN15 valve, pipe size 1/2" ACS-15W

Welding fitting for DN20 valve, pipe size 3/4" ACS-20W

Welding fitting for DN25 valve, pipe size 1" ACS-25W

Welding fitting for DN32 valve, pipe size 1 1/4" ACS-32W

For all DN15 V5872B to DN15 V5825B AK15-15

For V5872B1052 to V5825B1050 AK20-15

For V5872B1060 to V5825B1068 AK20-25

For V5872B1078 to V5825B1076 AK25-25

Page 114: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-13

2-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Springreturn

Type

Vac; VA s m

6,5 mm; 300 N 0/2..10V= 24; 1,4 – – – 150 1,5 – M7410E10280/2..10V= 24; 1,4 – • – 150 1,5 – M7410E20340/2..10V= 24; 1,4 – • 2 150 1,5 – M7410E4030

3-pt 24; 0,7 – – – 150 1,5 – M7410C10153-pt 24; 0,7 – • – 150 1,5 – M6410C20313-pt 24; 0,7 – • 2 150 1,5 – M6410C40373-pt 230; 7 – • – 150 1,5 – M6410L20313-pt 230; 7 – • 2 150 1,5 – M6410L4037LON 24; 1,4 – – – 150 1,5 – M7410G1024

6,5 mm; 400 N 0/2..10V= 24; 5 – • – 15 – – ML7430E10050/2..10V= 24; 10 valve closed – – 60 – • ML7435E1004

3-pt 24; 10 valve closed – – 60 – • ML6435B10083-pt 230; 10 valve closed – – 60 – • ML6435B1016

Page 115: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-14

2-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

2-way linear valves, stroke 20/38mm

For heating, ventilating and air conditioning; hot/cold water quality VDI2035.

20 mm, plug brass

20 mm, plug stainless steel

Two-way control valve PN16, threaded connections DN15-50, V5011R,S

Valve series V5011R/S

Valve type 2-way

Materials body brass, stem stainless steel; plug brass or stainless steel

Action to open stem up

Stroke 20 mm

Media temp. 2 ... 170 oC

Pressure rating PN16

Port connection internal threads ISO228

Flow char. mod.equal%

Medium type DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Type

mm kPa kPa

water 15 0,63 1600 – V5011R1000water 15 1 1600 – V5011R1018water 15 1,6 1600 – V5011R1026water 15 2,5 1600 – V5011R1034water 15 4 1600 – V5011R1042water 20 6,3 1600 – V5011R1059water 25 10 1000 1600 V5011R1067water 32 16 700 1600 V5011R1075water 40 25 460 1500 V5011R1083water 50 40 260 850 V5011R1091

Medium type DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Type

mm kPa kPa

water/steam 15 0,63 1600 – V5011S1005water/steam 15 1 1600 – V5011S1013water/steam 15 1,6 1600 – V5011S1021water/steam 15 2,5 1600 – V5011S1039water/steam 15 4 1600 – V5011S1047water/steam 20 6,3 1600 – V5011S1054water/steam 25 10 1000 1600 V5011S1062water/steam 32 16 700 1600 V5011S1070water/steam 40 25 460 1500 V5011S1088water/steam 50 40 260 850 V5011S1096

Page 116: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-15

2-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 valve open • optional 1,8 • 2..10V= ML7425B60070/2..10V= 24; 12 valve closed • optional 1,8 • 2..10V= ML7425A6008

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 valve open • optional 1,8 • optional ML6425B30053-pt 24; 11 valve closed • optional 1,8 • optional ML6425A30063-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 valve open • optional 1,8 • optional ML6425B30213-pt 230; 12 valve closed • optional 1,8 • optional ML6425A3014

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

Page 117: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-16

2-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For heating and air conditioning in closed circuit systems; hot/cold water quality VDI2035.

20 mm

38 mm

Two-way control valve PN16, flanged connections DN15-150, V5328A

Valve series V5328A

Valve type 2-way

Medium type water/steam

Materials body cast iron GG25, trim stainless steel

Action to open stem up

Pressure rating PN16

Port connection flanges ISO7005

Flow char. mod.equal%

Additional description Models DN15..50 approved according DIN EN 14597, with motors ML6425A, ML7425A.

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Type

mm kPa kPa mm oC

15 0,25 1600 – 20 2 ... 170 V5328A113815 0,4 1600 – 20 2 ... 170 V5328A114615 0,63 1600 – 20 2 ... 170 V5328A115315 1 1600 – 20 2 ... 170 V5328A100515 1,6 1600 – 20 2 ... 170 V5328A101315 2,5 1000 1600 20 2 ... 170 V5328A102115 4 1000 1600 20 2 ... 170 V5328A103920 4 1000 1600 20 2 ... 170 V5328A104720 6,3 1000 1600 20 2 ... 170 V5328A105425 10 1000 1600 20 2 ... 170 V5328A106232 16 600 1600 20 2 ... 170 V5328A107040 25 350 1300 20 2 ... 170 V5328A108850 40 200 750 20 2 ... 170 V5328A109665 63 120 470 20 2 ... 170 V5328A110480 100 50 230 20 2 ... 170 V5328A1112

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Type

mm kPa kPa mm oC

100 160 – 230 38 2 ... 200 V5328A1195125 250 – 90 38 2 ... 200 V5328A1203150 360 – 90 38 2 ... 200 V5328A1211

Page 118: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-17

2-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 valve open • optional 1,8 • 2..10V= ML7425B60070/2..10V= 24; 12 valve closed • optional 1,8 • 2..10V= ML7425A6008

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 valve open • optional 1,8 • optional ML6425B30053-pt 24; 11 valve closed • optional 1,8 • optional ML6425A30063-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 valve open • optional 1,8 • optional ML6425B30213-pt 230; 12 valve closed • optional 1,8 • optional ML6425A3014

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 119: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-18

2-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pressure balanced control valve for closed circuit systems.For district heating; hot or cold water (max. 50% glycol), water quality VDI2035; or steam.

20 mm

38 mm

Two-way control valve PN16, high differential pressure DN15-150, V5016A

Valve series V5016A

Valve type 2-way press. bal.

Medium type water/steam

Materials body nodular iron GGG40.3, trim stainless steel

Action to open stem up

Media temp. 2 ... 180 oC

Pressure rating PN16

Port connection flanges ISO7005

Flow char. mod.equal%

Additional description Models DN15..80 approved according DIN EN 14597, with motors ML6425A, ML7425A.

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

15 0,4 1600 – 20 V5016A101015 0,63 1600 – 20 V5016A102815 1 1600 – 20 V5016A103615 1,6 1600 – 20 V5016A104415 2,5 1600 – 20 V5016A105115 4 1600 – 20 V5016A106920 6,3 1600 – 20 V5016A107725 10 1600 – 20 V5016A108532 16 1600 – 20 V5016A109340 25 1600 – 20 V5016A110150 40 1600 – 20 V5016A111965 63 1600 – 20 V5016A112780 100 1600 – 20 V5016A1135

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

100 160 – 1600 38 V5016A1143125 250 – 1600 38 V5016A1150150 360 – 1600 38 V5016A1168

Page 120: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-19

2-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 valve open • optional 1,8 • 2..10V= ML7425B60070/2..10V= 24; 12 valve closed • optional 1,8 • 2..10V= ML7425A6008

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 valve open • optional 1,8 • optional ML6425B30053-pt 24; 11 valve closed • optional 1,8 • optional ML6425A30063-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 valve open • optional 1,8 • optional ML6425B30213-pt 230; 12 valve closed • optional 1,8 • optional ML6425A3014

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 121: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-20

2-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pressure balanced control valve for closed circuit systems.For district heating; hot or cold water (max. 50% glycol), water quality VDI2035; or steam.

20 mm

38 mm

Two-way control valve PN25, high differential pressure DN15-150, V5025A

Valve series V5025A

Valve type 2-way press. bal.

Medium type water/steam

Materials body nodular iron GGG40.3, trim stainless steel

Action to open stem up

Media temp. 2 ... 200 oC

Pressure rating PN25

Port connection flanges ISO7005

Flow char. mod.equal%

Additional description Models DN15..80 approved according DIN EN 14597, with motors ML6425A, ML7425A.

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

15 0,4 2500 – 20 V5025A101915 0,63 2500 – 20 V5025A102715 1 2500 – 20 V5025A103515 1,6 2500 – 20 V5025A104315 2,5 2500 – 20 V5025A105015 4 2500 – 20 V5025A106820 6,3 2500 – 20 V5025A107625 10 2500 – 20 V5025A108432 16 2500 – 20 V5025A109240 25 2500 – 20 V5025A110050 40 2500 – 20 V5025A111865 63 2500 – 20 V5025A112680 100 2500 – 20 V5025A1134

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

100 160 – 2500 38 V5025A1142125 250 – 2500 38 V5025A1159150 360 – 2500 38 V5025A1167

Page 122: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-21

2-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 valve open • optional 1,8 • 2..10V= ML7425B60070/2..10V= 24; 12 valve closed • optional 1,8 • 2..10V= ML7425A6008

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 valve open • optional 1,8 • optional ML6425B30053-pt 24; 11 valve closed • optional 1,8 • optional ML6425A30063-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 valve open • optional 1,8 • optional ML6425B30213-pt 230; 12 valve closed • optional 1,8 • optional ML6425A3014

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 123: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-22

2-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For heating and air conditioning in closed circuit systems; hot/cold water quality VDI2035.

20 mm

38 mm

Two-way control valve PN40, flanged connections DN15-100, V5049A

Valve series V5049

Valve type 2-way

Medium type water/steam

Materials body cast steel GS-C25, trim stainless steel

Action to open stem up

Media temp. 2 ... 220 oC

Pressure rating PN40

Port connection flanges ISO7005

Flow char. mod.equal%

Additional description Models DN15..65 approved according DIN EN 14597, with motors ML6425A, ML7425A.

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

15 0,25 1600 – 20 V5049A202715 0,4 1600 – 20 V5049A203515 0,63 1600 – 20 V5049A204315 1 1600 – 20 V5049A142515 1,6 1600 – 20 V5049A143315 2,5 1000 2500 20 V5049A144115 4 1000 2500 20 V5049A145820 6,3 1000 2500 20 V5049A150825 10 1000 2500 20 V5049A156532 16 600 2000 20 V5049A157340 25 350 1300 20 V5049A158150 40 200 750 20 V5049A159965 63 120 500 20 V5049A1607

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

80 100 – 230 38 V5049A1615100 160 – 230 38 V5049A1623

Page 124: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-23

2-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 valve open • optional 1,8 • 2..10V= ML7425B60070/2..10V= 24; 12 valve closed • optional 1,8 • 2..10V= ML7425A6008

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 valve open • optional 1,8 • optional ML6425B30053-pt 24; 11 valve closed • optional 1,8 • optional ML6425A30063-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 valve open • optional 1,8 • optional ML6425B30213-pt 230; 12 valve closed • optional 1,8 • optional ML6425A3014

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 125: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-24

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

3-way linear valves, stroke 2,5/6,5mm

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open; B-AB is linear and the Kvs is one stage smaller then A-AB

Accessories

Valve Small, Conical sealing, 3-way, PN16, DN15/20/25, VSxC-3

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOC-315-1.015 G1/2 1 600 – 2,5 on/off • VSOC-315-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOC-315-1.615 G1/2 1,6 300 – 2,5 on/off • VSOC-315-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOC-315-2.515 G1/2 2,5 150 – 2,5 on/off • VSOC-315-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOC-320-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOC-320-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOC-320-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOC-320-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOC-325-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOC-325-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,25 600 600 6,5 mod.equal% – VSMC-315-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMC-315-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMC-315-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMC-315-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMC-315-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMC-315-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMC-320-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMC-320-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMC-320-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMC-320-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMC-325-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMC-325-8.0P

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size R3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size R1/2" ACN-20T

External threaded fitting for DN25 valve, pipe size R1" ACN-25T

Page 126: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-25

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 127: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-26

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open; B-AB is linear and the Kvs is one stage smaller then A-AB

Accessories

Valve Small, Flat sealing, 3-way, PN16, DN15/20/25, VSxF-3

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOF-315-1.015 G1/2 1 600 – 2,5 on/off • VSOF-315-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOF-315-1.615 G1/2 1,6 300 – 2,5 on/off • VSOF-315-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOF-315-2.515 G1/2 2,5 150 – 2,5 on/off • VSOF-315-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOF-320-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOF-320-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOF-320-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOF-320-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOF-325-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOF-325-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,25 600 600 6,5 mod.equal% – VSMF-315-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMF-315-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMF-315-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMF-315-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMF-315-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMF-315-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMF-320-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMF-320-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMF-320-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMF-320-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMF-325-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMF-325-8.0P

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size R3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size R1/2" AC-20FT

External threaded fitting for DN25 valve, pipe size R1" ACS-25T

Page 128: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-27

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 129: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-28

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open; B-AB is linear and the Kvs is one stage smaller then A-AB

Accessories

Valve Small, Conical sealing, 3-way/bypass, PN16, DN15/20/25, VSxC-4

Valve type 3-way mixing, bypass

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOC-415-1.015 G1/2 1 600 – 2,5 on/off • VSOC-415-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOC-415-1.615 G1/2 1,6 300 – 2,5 on/off • VSOC-415-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOC-415-2.515 G1/2 2,5 150 – 2,5 on/off • VSOC-415-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOC-420-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOC-420-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOC-420-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOC-420-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOC-425-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOC-425-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,25 600 600 6,5 mod.equal% – VSMC-415-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMC-415-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMC-415-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMC-415-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMC-415-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMC-415-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMC-420-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMC-420-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMC-420-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMC-420-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMC-425-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMC-425-8.0P

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size R3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size R1/2" ACN-20T

External threaded fitting for DN25 valve, pipe size R1" ACN-25T

Page 130: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-29

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 131: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-30

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm On/off; adjustment cap for full stroke travel

6,5 mm Modulating; adjustment cap opens A-B half stroke until fully open; B-AB is linear and the Kvs is one stage smaller then A-AB

Accessories

Valve Small, Flat sealing, 3-way/bypass, PN16, DN15/20/25, VSxF-4

Valve type 3-way mixing, bypass

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 1 600 – 2,5 on/off – VSOF-415-1.015 G1/2 1 600 – 2,5 on/off • VSOF-415-1.0S15 G1/2 1,6 300 – 2,5 on/off – VSOF-415-1.615 G1/2 1,6 300 – 2,5 on/off • VSOF-415-1.6S15 G1/2 2,5 150 – 2,5 on/off – VSOF-415-2.515 G1/2 2,5 150 – 2,5 on/off • VSOF-415-2.5S20 1 1/8 x 14 2,5 200 – 2,5 on/off – VSOF-420-2.520 1 1/8 x 14 2,5 200 – 2,5 on/off • VSOF-420-2.5S20 1 1/8 x 14 4 100 – 2,5 on/off – VSOF-420-4.020 1 1/8 x 14 4 100 – 2,5 on/off • VSOF-420-4.0S25 G1 1/4 4 200 – 2,5 on/off – VSOF-425-4.0P25 G1 1/4 5,5 200 – 2,5 on/off – VSOF-425-5.5P

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Snap-on MT Type

mm inch kPa kPa mm

15 G1/2 0,25 600 600 6,5 mod.equal% – VSMF-415-0.2515 G1/2 0,4 600 600 6,5 mod.equal% – VSMF-415-0.415 G1/2 0,63 600 600 6,5 mod.equal% – VSMF-415-0.6315 G1/2 1 600 600 6,5 mod.equal% – VSMF-415-1.015 G1/2 1,6 300 300 6,5 mod.equal% – VSMF-415-1.615 G1/2 2,5 100 100 6,5 mod.equal% – VSMF-415-2.520 1 1/8 x 14 2,5 150 150 6,5 mod.equal% – VSMF-420-2.520 1 1/8 x 14 2,5 – 250 6,5 mod.equal% – VSMF-420-2.5E20 1 1/8 x 14 4 50 50 6,5 mod.equal% – VSMF-420-4.020 1 1/8 x 14 4 – 250 6,5 mod.equal% – VSMF-420-4.0E25 G1 1/4 6,3 250 250 6,5 mod.equal% – VSMF-425-6.3P25 G1 1/4 8 250 250 6,5 mod.equal% – VSMF-425-8.0P

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size R3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size R1/2" AC-20FT

External threaded fitting for DN25 valve, pipe size R1" ACS-25T

Page 132: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-31

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 133: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-32

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Three-way control valve PN16, conical sealing DN15/20, V5823A

Valve series V5823A

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap (not for on/off types). If the main-port (A-AB) is equal percentage, the B-AB port is linear. The valve capacity of B-AB is one stage smaller.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 150 – 2,5 on/off V5823A400920 1 1/8" x 14 2,5 50 – 2,5 on/off V5823A4017

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,25 500 800 6,5 mod.equal% V5823A200315 G1/2 0,4 500 800 6,5 mod.equal% V5823A201115 G1/2 0,63 500 800 6,5 mod.equal% V5823A202915 G1/2 1 150 250 6,5 mod.equal% V5823A203715 G1/2 1,6 150 250 6,5 mod.equal% V5823A204520 1 1/8" x 14 2,5 – 240 6,5 mod.equal% V5823A215120 1 1/8" x 14 2,5 50 100 6,5 mod.equal% V5823A205220 1 1/8" x 14 4 – 240 6,5 mod.equal% V5823A216920 1 1/8" x 14 4 50 100 6,5 mod.equal% V5823A2060

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size 3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size 1/2" ACN-20T

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 134: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-33

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 135: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-34

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Three-way/bypass control valve PN16, conical sealing DN15/20, V5823C

Valve series V5823C

Valve type 3-way mixing, bypass

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread con. sealing

Additional description Valves are supplied with adjustment cap (not for on/off types). If the main-port (A-AB) is equal percentage, the B-AB port is linear. The valve capacity of B-AB is one stage smaller.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 150 – 2,5 on/off V5823C400520 1 1/8" x 14 2,5 50 – 2,5 on/off V5823C4013

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,25 500 800 6,5 mod.equal% V5823C200915 G1/2 0,4 500 800 6,5 mod.equal% V5823C201715 G1/2 0,63 500 800 6,5 mod.equal% V5823C202515 G1/2 1 150 250 6,5 mod.equal% V5823C203315 G1/2 1,6 150 250 6,5 mod.equal% V5823C204120 1 1/8" x 14 2,5 – 240 6,5 mod.equal% V5823C215720 1 1/8" x 14 2,5 50 100 6,5 mod.equal% V5823C205820 1 1/8" x 14 4 – 240 6,5 mod.equal% V5823C216520 1 1/8" x 14 4 50 100 6,5 mod.equal% V5823C2066

Compression fitting for DN15 valve, pipe size 15 mm ACN-15C

Compression fitting for DN20 valve, pipe size 22 mm ACN-20C

Soldering fitting for DN15 valve, pipe size 12 mm ACN-15S

Soldering fitting for DN20 valve, pipe size 15 mm ACN-20S

External threaded fitting for DN15 valve, pipe size 3/8" ACN-15T

External threaded fitting for DN20 valve, pipe size 1/2" ACN-20T

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 136: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-35

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 137: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-36

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Three-way control valve PN16, flat sealing DN15/20, V5833A

Valve series V5833A

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap (not for on/off types). If the main-port (A-AB) is equal percentage, the B-AB port is linear. The valve capacity of B-AB is one stage smaller.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 150 – 2,5 on/off V5833A400720 G3/4 2,5 50 – 2,5 on/off V5833A4015

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,25 500 800 6,5 mod.equal% V5833A100315 G1/2 0,4 500 800 6,5 mod.equal% V5833A101115 G1/2 0,63 500 800 6,5 mod.equal% V5833A102915 G1/2 1 150 250 6,5 mod.equal% V5833A103715 G1/2 1,6 150 250 6,5 mod.equal% V5833A104520 G3/4 2,5 – 240 6,5 mod.equal% V5833A300920 G3/4 2,5 50 100 6,5 mod.equal% V5833A105220 G3/4 4 – 240 6,5 mod.equal% V5833A301720 G3/4 4 50 100 6,5 mod.equal% V5833A1060

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size 3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size 1/2" AC-20FT

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 138: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-37

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 139: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-38

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

2,5 mm

6,5 mm

Accessories

Three-way/bypass control valve PN16, flat sealing DN15/20, V5833C

Valve series V5833C

Valve type 3-way mixing, bypass

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Additional description Valves are supplied with adjustment cap (not for on/off types). The valve capacity for linear ports is one stage smaller than for equal percentage ports.

DNsize

Connectiondiameter

Kvsvalue

Close off pressurewith 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 1,6 150 – 2,5 on/off V5833C400320 G3/4 2,5 50 – 2,5 on/off V5833C4011

DNsize

Connectiondiameter

Kvsvalue

Close off pressure with 90N motor

Close off pressurewith 180N motor

Stroke Flow char. Type

mm inch kPa kPa mm

15 G1/2 0,25 500 800 6,5 mod.equal% V5833C106615 G1/2 0,4 500 800 6,5 mod.equal% V5833C100915 G1/2 0,63 500 800 6,5 mod.equal% V5833C101715 G1/2 1 150 250 6,5 mod.equal% V5833C102515 G1/2 1,6 150 250 6,5 mod.equal% V5833C103320 G3/4 2,5 – 240 6,5 mod.equal% V5833C114020 G3/4 2,5 50 100 6,5 mod.equal% V5833C104120 G3/4 4 – 240 6,5 mod.equal% V5833C115220 G3/4 4 50 100 6,5 mod.equal% V5833C1058

Soldering fitting for DN15 valve, pipe size 12 mm AC-15FS

Soldering fitting for DN20 valve, pipe size 15 mm AC-20FS

External threaded fitting for DN15 valve, pipe size 3/8" AC-15FT

External threaded fitting for DN20 valve, pipe size 1/2" AC-20FT

Service tool to clean/replace inserts WV108

Brush for WV108 WV108B

Page 140: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-39

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Type

Vac; VA m

2,5 mm; 90 N 0..10V= 24; 2 A-AB open – – 75 s 1 MT010-N0..10V= 24; 2 A-AB open – – 75 s 3 MT010-3MN

2-pt 24; 2 A-AB open – – 4 min 1 MT4-024-NC2-pt 24; 2 A-AB open – – 4 min 2,5 MT4-024-NC-2.5M2-pt 24; 2 A-AB open – 1 4 min 1 MT4-024S-NC2-pt 24; 2 A-AB closed – – 4 min 1 MT4-024-NO2-pt 24; 2 A-AB closed – – 4 min 2,5 MT4-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 4 min 1 MT4-024S-NO2-pt 230; 2 A-AB open – – 4 min 1 MT4-230-NC2-pt 230; 2 A-AB open – – 4 min 2,5 MT4-230-NC-2.5M2-pt 230; 2 A-AB open – 1 4 min 1 MT4-230S-NC2-pt 230; 2 A-AB closed – – 4 min 1 MT4-230-NO2-pt 230; 2 A-AB closed – – 4 min 2,5 MT4-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 4 min 1 MT4-230S-NO3-pt 24; 0,7 – – – 57 s 0,9 M7410A1001LON 24; 1,4 – – – 53 s 1,5 M7410G1008

6,5 mm; 90 N 2-pt 24; 2 A-AB open – – 6 min 1 MT8-024-NC2-pt 24; 2 A-AB open – – 6 min 2,5 MT8-024-NC-2.5M2-pt 24; 2 A-AB open – 1 6 min 1 MT8-024S-NC2-pt 24; 8 A-AB closed – – 3,6/16 s 1,5 M5410C10012-pt 24; 2 A-AB closed – – 6 min 1 MT8-024-NO2-pt 24; 2 A-AB closed – – 6 min 2,5 MT8-024-NO-2.5M2-pt 24; 2 A-AB closed – 1 6 min 1 MT8-024S-NO2-pt 230; 2 A-AB open – – 6,5 min 1 MT8-230-NC2-pt 230; 2 A-AB open – – 6,5 min 2,5 MT8-230-NC-2.5M2-pt 230; 2 A-AB open – 1 6,5 min 1 MT8-230S-NC2-pt 230; 15 A-AB closed – – 3,6/16 s 1,5 M5410L10012-pt 230; 2 A-AB closed – – 6,5 min 1 MT8-230-NO2-pt 230; 2 A-AB closed – – 6,5 min 2,5 MT8-230-NO-2.5M2-pt 230; 2 A-AB closed – 1 6,5 min 1 MT8-230S-NO

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – – 150 s 1,5 M7410E10020/2..10V= 24; 1,4 – • – 150 s 1,5 M7410E20260/2..10V= 24; 1,4 – • 2 150 s 1,5 M7410E4022

3-pt 24; 0,7 – – – 150 s 1,5 M7410C10073-pt 24; 0,7 – • – 150 s 1,5 M6410C20233-pt 24; 0,7 – • 2 150 s 1,5 M6410C40293-pt 230; 7 – • – 150 s 1,5 M6410L20233-pt 230; 7 – • 2 150 s 1,5 M6410L4029LON 24; 1,4 – – – 150 s 1,5 M7410G1016

Page 141: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-40

3-way linear valves, stroke 2,5/6,5mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pressure balanced control valve.For fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water quality VDI2035.

6,5 mm

Accessories

Three-way control valve PN16, flat sealing DN25-40, V5833A

Valve series V5833A2

Valve type 3-way mixing, press. bal.

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Stroke 6,5 mm

Media temp. 2 ... 130 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Flow char. linear

Additional description Valves are supplied with adjustment cap.

DN size Connectiondiameter

Kvs value Close off pressurewith 300N motor

Close off pressurewith 400N motor

Type

mm inch kPa kPa

25 G1 1/2 4 600 1600 V5833A207625 G1 1/2 6,3 600 1600 V5833A208425 G1 1/2 10 600 1600 V5833A209232 G2 16 300 1200 V5833A210040 G2 1/4 25 – 1000 V5833A2118

External threaded fitting for DN25 valve, pipe size R1" AC-25T

External threaded fitting for DN32 valve, pipe size R11/4" AC-32T

External threaded fitting for DN40 valve, pipe size R11/2" AC-40T

Internal threaded fitting for DN25 valve, pipe size Rp1" AC-25TF

Internal threaded fitting for DN32 valve, pipe size Rp11/4" AC-32TF

Internal threaded fitting for DN40 valve, pipe size Rp11/2" AC-40TF

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Cablelength

Springreturn

Type

Vac; VA s m

6,5 mm; 300 N 0/2..10V= 24; 1,4 – – – 150 1,5 – M7410E10280/2..10V= 24; 1,4 – • – 150 1,5 – M7410E20340/2..10V= 24; 1,4 – • 2 150 1,5 – M7410E4030

3-pt 24; 0,7 – – – 150 1,5 – M7410C10153-pt 24; 0,7 – • – 150 1,5 – M6410C20313-pt 24; 0,7 – • 2 150 1,5 – M6410C40373-pt 230; 7 – • – 150 1,5 – M6410L20313-pt 230; 7 – • 2 150 1,5 – M6410L4037LON 24; 1,4 – – – 150 1,5 – M7410G1024

6,5 mm; 400 N 0/2..10V= 24; 5 – • – 15 – – ML7430E10050/2..10V= 24; 10 A-AB closed – – 60 – • ML7435E1004

3-pt 24; 10 A-AB closed – – 60 – • ML6435B10083-pt 230; 10 A-AB closed – – 60 – • ML6435B1016

Page 142: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-41

3-way linear valves, stroke 2,5/6,5mm

2

3

4

5

6

7

8

10

9

11

12

13

14

For under floor heating, heating and air conditioning; cold/hot water.

6,5 mm

Three-way control valve PN16, threaded connections DN15-50, V5078B

Valve series V5078B

Valve type 3-way mixing

Medium type water

Materials body red brass RG5, trim stainless steel

Action to open stem down

Close off pressure with 180N motor

1000 kPa

Stroke 6,5 mm

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection internal threads ISO228

Flow char. mod.equal%

Additional description Adaper ring 0903403 must be used for mechanical interface; and must be ordered seperately.

DN size Connection diameter Kvs value Typemm inch

15 1/2 2,5 V5078B100520 3/4 3,3 V5078B101325 1 5 V5078B102132 1 1/4 5 V5078B103940 1 1/2 11 V5078B104750 2 13 V5078B1054

Actuators Control input signal Power supply Manual operation End switches Runtime Cable length TypeVac; VA s m

6,5 mm; 180 N 0/2..10V= 24; 1,4 – – 150 1,5 M7410E10020/2..10V= 24; 1,4 • – 150 1,5 M7410E20260/2..10V= 24; 1,4 • 2 150 1,5 M7410E4022

3-pt 24; 0,7 – – 150 1,5 M7410C10073-pt 24; 0,7 • – 150 1,5 M6410C20233-pt 24; 0,7 • 2 150 1,5 M6410C40293-pt 230; 7 • – 150 1,5 M6410L20233-pt 230; 7 • 2 150 1,5 M6410L4029LON 24; 1,4 – – 150 1,5 M7410G1016

Page 143: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-42

3-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

3-way linear valves, stroke 20/38mm

For heating, ventilating and air conditioning, open circuits; hot/cold water quality VDI2035.

20 mm

Accessories

Three-way control valve PN16, flat sealing DN15-50, V5013E

Valve series V5013E

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Stroke 20 mm

Media temp. 2 ... 170 oC

Pressure rating PN16

Port connection ext. thread flat sealing

Flow char. mod.equal%

DN size Connectiondiameter

Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Type

mm inch kPa kPa

15 G1 1/8 2,5 1600 – V5013E106315 G1 1/8 4 1600 – V5013E107120 G1 1/4 6,3 1600 – V5013E108925 G1 1/2 10 1000 1600 V5013E109732 G2 16 700 1600 V5013E110540 G2 1/4 25 460 1500 V5013E111350 G2 3/4 40 260 850 V5013E1121

Internal threaded fitting for DN15 valve, pipe size Rp1/2" AC-15TF

Internal threaded fitting for DN20 valve, pipe size Rp3/4" AC-20TF

Internal threaded fitting for DN25 valve, pipe size Rp1" AC-25TF

Internal threaded fitting for DN32 valve, pipe size Rp1 1/4" AC-32TF

Internal threaded fitting for DN40 valve, pipe size Rp1 1/2" AC-40TF

Internal threaded fitting for DN50 valve, pipe size Rp2" AC-50TF

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 A-AB open • optional 1,8 • 2..10V= ML7425A60080/2..10V= 24; 12 A-AB closed • optional 1,8 • 2..10V= ML7425B6007

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 A-AB open • optional 1,8 • optional ML6425A30063-pt 24; 11 A-AB closed • optional 1,8 • optional ML6425B30053-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 A-AB open • optional 1,8 • optional ML6425A30143-pt 230; 12 A-AB closed • optional 1,8 • optional ML6425B3021

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

Page 144: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-43

3-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

For heating, ventilating and air conditioning, open circuits; hot/cold water quality VDI2035.

20 mm

Three-way control valve PN16, threaded connections DN15-50, V5013R

Valve series V5013R

Valve type 3-way mixing

Medium type water

Materials body brass, stem stainless steel, plug brass

Action to open stem down

Stroke 20 mm

Media temp. 2 ... 170 oC

Pressure rating PN16

Port connection internal threads ISO228

Flow char. mod.equal%

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Type

mm kPa kPa

15 2,5 1600 – V5013R103215 4 1600 – V5013R104020 6,3 1600 – V5013R105725 10 1000 1600 V5013R106532 16 700 1600 V5013R107340 25 460 1500 V5013R108150 40 260 850 V5013R1099

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 A-AB open • optional 1,8 • 2..10V= ML7425A60080/2..10V= 24; 12 A-AB closed • optional 1,8 • 2..10V= ML7425B6007

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 A-AB open • optional 1,8 • optional ML6425A30063-pt 24; 11 A-AB closed • optional 1,8 • optional ML6425B30053-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 A-AB open • optional 1,8 • optional ML6425A30143-pt 230; 12 A-AB closed • optional 1,8 • optional ML6425B3021

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

Page 145: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-44

3-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For heating and air conditioning in closed circuit systems; hot/cold water quality VDI2035, greenhouses.

20 mm

38 mm

Three-way control valve PN6, flanged connections DN15-150, V5329C/V5015A

Valve series V5329C/V5015

Valve type 3-way mixing

Medium type water

Materials body cast iron GG25, trim stainless steel

Action to open stem down

Pressure rating PN6

Port connection flanges ISO7005

Flow char. mod.equal%

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Type

mm kPa kPa mm oC

15 2,5 600 – 20 2 ... 170 V5329C100015 4 600 – 20 2 ... 170 V5329C101820 6,3 600 – 20 2 ... 170 V5329C102625 10 600 – 20 2 ... 170 V5329C103432 16 600 – 20 2 ... 170 V5329C104240 25 480 600 20 2 ... 170 V5329C105950 40 260 600 20 2 ... 170 V5329C106765 63 160 600 20 2 ... 170 V5329C107580 100 100 400 20 2 ... 170 V5329C1083

DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Type

mm kPa kPa mm oC

100 140 – 150 38 2 ... 120 V5015A1151125 220 – 120 38 2 ... 120 V5015A1169150 310 – 80 38 2 ... 120 V5015A1177

Page 146: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-45

3-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 A-AB open • optional 1,8 • 2..10V= ML7425A60080/2..10V= 24; 12 A-AB closed • optional 1,8 • 2..10V= ML7425B6007

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 A-AB open • optional 1,8 • optional ML6425A30063-pt 24; 11 A-AB closed • optional 1,8 • optional ML6425B30053-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 A-AB open • optional 1,8 • optional ML6425A30143-pt 230; 12 A-AB closed • optional 1,8 • optional ML6425B3021

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 147: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-46

3-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For heating and air conditioning in closed circuit systems; hot/cold water quality VDI2035, greenhouses.

20 mm

38 mm, mixing

38 mm, diverting, action to open AB-A: stem up

Three-way control valve PN16, flanged connections DN 15-150, V5329A/V5050A,B

Valve series V5329A/V5050

Medium type water

Materials body cast iron GG25, trim stainless steel

Action to open stem down

Pressure rating PN16

Port connection flanges ISO7005

Valve type DNsize

Kvsvalue

Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Flow char. Type

mm kPa kPa mm oC

3-way mixing 15 2,5 1000 – 20 2 ... 170 mod.equal% V5329A10043-way mixing 15 4 1000 – 20 2 ... 170 mod.equal% V5329A10123-way mixing 20 6,3 1000 – 20 2 ... 170 mod.equal% V5329A10203-way mixing 25 10 1000 – 20 2 ... 170 mod.equal% V5329A10383-way mixing 32 16 790 1000 20 2 ... 170 mod.equal% V5329A10463-way mixing 40 25 480 1000 20 2 ... 170 mod.equal% V5329A10533-way mixing 50 40 260 1000 20 2 ... 170 mod.equal% V5329A10613-way mixing 65 63 160 650 20 2 ... 170 mod.equal% V5329A10793-way mixing 80 100 100 400 20 2 ... 170 mod.equal% V5329A1087

Valve type DNsize

Kvsvalue

Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Flow char. Type

mm kPa kPa mm oC

3-way mixing 100 160 – 230 38 2 ... 220 linear V5050A10903-way mixing 125 250 – 90 38 2 ... 220 linear V5050A11083-way mixing 150 360 – 90 38 2 ... 220 linear V5050A1116

Valve type DNsize

Kvsvalue

Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Media temp. Flow char. Type

mm kPa kPa mm oC

3-waydiverting

100 160 – 230 38 2 ... 220 linear V5050B1064

3-waydiverting

125 250 – 90 38 2 ... 220 linear V5050B1072

3-waydiverting

150 360 – 90 38 2 ... 220 linear V5050B1080

Page 148: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-47

3-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 A-AB open • optional 1,8 • 2..10V= ML7425A60080/2..10V= 24; 12 A-AB closed • optional 1,8 • 2..10V= ML7425B6007

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 A-AB open • optional 1,8 • optional ML6425A30063-pt 24; 11 A-AB closed • optional 1,8 • optional ML6425B30053-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 A-AB open • optional 1,8 • optional ML6425A30143-pt 230; 12 A-AB closed • optional 1,8 • optional ML6425B3021

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 149: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-48

3-way linear valves, stroke 20/38mm

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For closed circuit heating systems, hot water quality VDI2035.

20 mm

38 mm, mixing

38 mm, diverting, action to open AB-A: stem up

Three-way control valve PN25/40, flanged connections DN15-100, V5050A,B

Valve series V5050

Medium type water

Materials body cast steel GS-C25, trim stainless steel

Action to open stem down

Media temp. 2 ... 220 oC

Pressure rating PN25/40

Port connection flanges ISO7005

Flow char. linear

Valve type DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

3-way mixing 15 2,5 1000 2500 20 V5050A11243-way mixing 15 4 1000 2500 20 V5050A11323-way mixing 20 6,3 1000 2500 20 V5050A11403-way mixing 25 10 1000 2500 20 V5050A11573-way mixing 32 16 600 2000 20 V5050A11653-way mixing 40 25 350 1300 20 V5050A11733-way mixing 50 40 200 750 20 V5050A11813-way mixing 65 63 120 500 20 V5050A11993-way mixing 80 100 50 230 20 V5050A1207

Valve type DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

3-way mixing 100 160 – 230 38 V5050A1215

Valve type DN size Kvs value Close off pressurewith 600N motor

Close off pressurewith 1800N motor

Stroke Type

mm kPa kPa mm

3-way diverting 100 160 – 230 38 V5050B1155

Page 150: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-49

3-way linear valves, stroke 20/38mm

2

3

4

5

6

7

8

10

9

11

12

13

14

Actuators Control inputsignal

Powersupply

Power lossaction

Manualoperation

Endswitches

Runtime Springreturn

Positionfeedback

Type

Vac; VA min

20 mm; 600 N 0/2..10V= 24; 7 – • optional 0,5 – 2..10V= ML7420A60170/2..10V= 24; 5 – • optional 1,0 – 2..10V= ML7420A60090/2..10V= 24; 12 A-AB open • optional 1,8 • 2..10V= ML7425A60080/2..10V= 24; 12 A-AB closed • optional 1,8 • 2..10V= ML7425B6007

2..10V= 24; 5 – – optional 1,0 – – ML7420A60253-pt 24; 4 – – optional 1,0 – optional ML6420A30723-pt 24; 6 – • optional 0,5 – optional ML6420A30233-pt 24; 4 – • optional 1,0 – optional ML6420A30073-pt 24; 11 A-AB open • optional 1,8 • optional ML6425A30063-pt 24; 11 A-AB closed • optional 1,8 • optional ML6425B30053-pt 230; 6,5 – • optional 0,5 – optional ML6420A30313-pt 230; 6,5 – • optional 1,0 – optional ML6420A30153-pt 230; 12 A-AB open • optional 1,8 • optional ML6425A30143-pt 230; 12 A-AB closed • optional 1,8 • optional ML6425B3021

20 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 1,9 – 2..10V= ML7421A3004

3-pt 24; 13 – • optional 1,9 – optional ML6421A30053-pt 230; 11 – • optional 1,9 – – ML6421A3013

38 mm; 1800 N 0/2..10V=;0/4..20mA

24; 12 – • optional 3,5 – 2..10V= ML7421B3003

3-pt 24; 13 – • optional 3,5 – optional ML6421B30043-pt 230; 11 – • optional 3,5 – – ML6421B3012

Page 151: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

5-50 http://products.ecc.emea.honeywell.com/europe

Page 152: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Valves rotary Page

Butterfly valves 6-2Rotary valves 6-4

Page 153: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-2

Butterfly valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Butterfly valves

For heating applications, or boiler management systems.For heating water containing up to 50% glycol. Other additives possible, but contact Honeywell for confirmation.

Spare parts

Butterfly valve DN25..200, without actuator

Valve series V5421B

Valve type butterfly for motor

Medium type water

Materials rotary disc DN25-80 stainless steel 1.4581, DN100-200 ductile iron GGG40; coating DeltaMagni

Packing EPDM

Angle of rotation 90 o

Pressure rating PN16

Port connection wafer

Additional description Without flanges. Actuators (M60.., M70.., M6422L1003) to be ordered seperatley.

DN size Kvs value Max. delta P Torque for max. delta P Media temp. Typemm kPa Nm oC

25 26 1600 8 -10 ... 120 V5421B100932 26 1600 8 -10 ... 120 V5421B101740 50 1600 12 -10 ... 120 V5421B102550 116 1000 12 -10 ... 120 V5421B103365 259 1000 15 -10 ... 120 V5421B104180 377 1000 25 -10 ... 120 V5421B1058

100 763 800 40 -10 ... 120 V5421B1066125 1030 600 40 0 ... 90 V5421B1074150 1790 400 40 0 ... 90 V5421B1082200 3460 300 60 0 ... 90 V5421B1090

Coupling set DN25-150 VCU-SET

Universal console VCO2

M60

61A1

021

M60

61A1

039

M60

61A1

047

M60

61L1

027

M60

61L1

035

M60

61L1

043

M64

22L1

003

M70

61E1

020

3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 0/2..10V= Control input signal24; 3,5 24; 3,5 24; 3,5 230; 3,5 230; 3,5 230; 3,5 230; 7 24; 2,4 Power supply [Vac; VA]

20 30 40 20 30 40 40 20 Torque [Nm]

• – – • – – – • V5421B1009• – – • – – – • V5421B1017• – – • – – – • V5421B1025• – – • – – – • V5421B1033• – – • – – – • V5421B1041– • – – • – – – V5421B1058– – • – – • – – V5421B1066– – • – – • – – V5421B1074– – • – – • – – V5421B1082– – – – – – • – V5421B1090

Page 154: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-3

Butterfly valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Butterfly valve with factory mounted electrical actuator.For heating water containing up to 50% glycol. Other additives possible, but contact Honeywell for confirmation.

3-pt control, with 2x SPST 230 Vac end switches for open/close feedback

Modulating control and electrical position indication, Microswitch settings for signals values 0/2..10V, 0/4..20mA

Motorized Butterfly valve DN250..300

Valve series V5422L/E

Valve type butterfly motorized

Medium type water

Materials body and disc ductile iron GGG40, disc coating DeltaMagni, shaft stainless steel 1.4021

Packing EPDM

Protection class IP67

Position indication mechanical pointer

Max. delta P 1000 kPa

Angle of rotation max. 90 o

Pressure rating PN10

Port connection wafer

Manual operation with wheel

Power supply 230 Vac; 276 VA

Runtime 30 s

Media temp. -10 ... 120 oC

Additional description Without flanges.

DN size Kvs value Torque Control input signal Typemm Nm

250 5070 250 3-pt V5422L1006300 7430 600 3-pt V5422L1014

DN size Kvs value Torque Control input signal Typemm Nm

250 5070 250 0/2..10V=; 0/4..20mA V5422E1001300 7430 600 0/2..10V=; 0/4..20mA V5422E1019

Page 155: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-4

Rotary valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Rotary valves

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.

Internal threads

Flanges

Three-way rotary valve PN6

Valve series DRG

Valve type 3-way rotary mixing

Medium type water

Materials body cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 130 oC

Pressure rating PN6

Reduced delta P 40 kPa

DN size Kvs value Max. delta P Torque for max. delta P Torque for reduced delta P Port connection Typemm kPa Nm Nm

15 2,5 100 10 10 internal threads DR15-2GMLA15 4 100 10 10 internal threads DR15GMLA20 6,3 100 10 10 internal threads DR20GMLA25 10 100 10 10 internal threads DR25GMLA32 16 100 10 10 internal threads DR32GMLA40 25 100 20 10 internal threads DR40GMLA

DN size Kvs value Max. delta P Torque for max. delta P Torque for reduced delta P Port connection Typemm kPa Nm Nm

20 6,3 100 10 10 flanges DIN2531 DR20GFLA25 10 100 10 10 flanges DIN2531 DR25GFLA32 16 100 10 10 flanges DIN2531 DR32GFLA40 25 100 20 10 flanges DIN2531 DR40GFLA50 40 100 20 20 flanges DIN2531 DR50GFLA65 63 100 20 20 flanges DIN2531 DR65GFLA80 100 100 30 20 flanges DIN2531 DR80GFLA

100 160 100 40 30 flanges DIN2531 DR100GFLA125 250 70 40 30 flanges DIN2531 DR125GFLA150 630 50 40 40 flanges DIN2531 DR150GFLA200 1000 50 40 40 flanges DIN2531 DR200GFLA1200 1600 50 40 40 flanges DIN2531 DR200GFLA

Page 156: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-5

Rotary valves

2

3

4

5

6

7

8

10

9

11

12

13

14

M60

61A1

013

M60

61A1

021

M60

61A1

039

M60

61A1

047

M60

61L1

019

M60

61L1

027

M60

61L1

035

M60

61L1

043

M70

61E1

012

M70

61E1

020

3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 0/2..10V= 0/2..10V= Control input signal24; 3,5 24; 3,5 24; 3,5 24; 3,5 230; 3,5 230; 3,5 230; 3,5 230; 3,5 24; 2,4 24; 2,4 Power supply [Vac; VA]

10 20 30 40 10 20 30 40 10 20 Torque [Nm]

• – – – • – – – • – DR15-2GMLA• – – – • – – – • – DR15GMLA• – – – • – – – • – DR20GMLA• – – – • – – – • – DR25GMLA• – – – • – – – • – DR32GMLA• • – – • • – – • • DR40GMLA• – – – • – – – • – DR20GFLA• – – – • – – – • – DR25GFLA• – – – • – – – • – DR32GFLA• • – – • • – – • • DR40GFLA– • – – – • – – – • DR50GFLA– • – – – • – – – • DR65GFLA– • • – – • • – – – DR80GFLA– – • • – – • • – – DR100GFLA– – • • – – • • – – DR125GFLA– – – • – – – • – – DR150GFLA– – – • – – – • – – DR200GFLA1– – – • – – – • – – DR200GFLA

Page 157: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-6

Rotary valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.

Three-way rotary valve PN6, compact

Valve series V5433A

Valve type 3-way rotary mixing, compact

Medium type water

Materials body cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 110 oC

Pressure rating PN6

Port connection internal threads

Max. delta P 100 kPa

Torque for max. delta P 7 Nm

DN size Kvs value Typemm

20 2,5 V5433A101520 4 V5433A102320 6,3 V5433A103125 10 V5433A104932 16 V5433A105640 25 V5433A106450 40 V5433A1072

M60

63A1

003

M60

63A4

007

M60

63L1

009

M60

63L4

003

3-pt 3-pt 3-pt 3-pt Control input signal24; 3 24; 3 230; 3 230; 3 Power supply [Vac; VA]

7 7 7 7 Torque [Nm]

• • • • V5433A1015• • • • V5433A1023• • • • V5433A1031• • • • V5433A1049• • • • V5433A1056• • • • V5433A1064• • • • V5433A1072

Page 158: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-7

Rotary valves

2

3

4

5

6

7

8

10

9

11

12

13

14

For hot/cold water quality VDI2035; glycol water mixture 50%.

Three-way rotary valve PN6, compact, chrome plated

Valve series V5433G

Valve type 3-way rotary mixing, compact

Medium type water

Materials body chrome plated cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 110 oC

Pressure rating PN6

Port connection internal threads

Max. delta P 100 kPa

Torque for max. delta P 7 Nm

DN size Kvs value Typemm

20 2,5 V5433G100420 4 V5433G101220 6,3 V5433G102025 10 V5433G103832 16 V5433G104640 25 V5433G105350 40 V5433G1061

M60

63A1

003

M60

63A4

007

M60

63L1

009

M60

63L4

003

3-pt 3-pt 3-pt 3-pt Control input signal24; 3 24; 3 230; 3 230; 3 Power supply [Vac; VA]

7 7 7 7 Torque [Nm]

• • • • V5433G1004• • • • V5433G1012• • • • V5433G1020• • • • V5433G1038• • • • V5433G1046• • • • V5433G1053• • • • V5433G1061

Page 159: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-8

Rotary valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.

Internal threads

Flanges

Four-way rotary valve PN6

Valve series ZR

Valve type 4-way rotary mixing

Medium type water

Materials body cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Pressure rating PN6

DNsize

Kvsvalue

Max.delta P

Torque formax. delta P

Reduceddelta P

Torque forreduced delta P

Mediatemp.

Portconnection

Type

mm kPa Nm kPa Nm oC

15 4 100 20 80 10 2 ... 130 internal threads ZR15MA20 6,3 100 20 80 10 2 ... 130 internal threads ZR20MA25 10 100 20 80 10 2 ... 130 internal threads ZR25MA32 16 100 20 80 10 2 ... 130 internal threads ZR32MA40 25 100 20 70 10 2 ... 130 internal threads ZR40MA

DNsize

Kvsvalue

Max.delta P

Torque formax. delta P

Reduceddelta P

Torque forreduced delta P

Mediatemp.

Portconnection

Type

mm kPa Nm kPa Nm oC

25 10 100 20 80 10 2 ... 130 flanges DIN2531 ZR25FA32 16 100 20 80 10 2 ... 130 flanges DIN2531 ZR32FA40 25 100 20 70 10 2 ... 130 flanges DIN2531 ZR40FA50 40 100 20 100 20 2 ... 130 flanges DIN2531 ZR50FA65 63 100 20 100 20 2 ... 130 flanges DIN2531 ZR65FA80 100 100 30 100 30 2 ... 130 flanges DIN2531 ZR80FA

100 160 80 30 80 30 2 ... 130 flanges DIN2531 ZR100FA125 250 50 30 50 30 2 ... 130 flanges DIN2531 ZR125FA150 400 40 30 40 30 2 ... 130 flanges DIN2531 ZR150FA200 630 30 30 30 30 2 ... 110 flanges DIN2531 ZR200FA

M60

61A1

013

M60

61A1

021

M60

61A1

039

M60

61L1

019

M60

61L1

027

M60

61L1

035

M70

61E1

012

M70

61E1

020

3-pt 3-pt 3-pt 3-pt 3-pt 3-pt 0/2..10V= 0/2..10V= Control input signal24; 3,5 24; 3,5 24; 3,5 230; 3,5 230; 3,5 230; 3,5 24; 2,4 24; 2,4 Power supply [Vac; VA]

10 20 30 10 20 30 10 20 Torque [Nm]

• • – • • – • • ZR15MA• • – • • – • • ZR20MA• • – • • – • • ZR25MA• • – • • – • • ZR32MA• • – • • – • • ZR40MA• • – • • – • • ZR25FA• • – • • – • • ZR32FA• • – • • – • • ZR40FA– • – – • – – • ZR50FA– • – – • – – • ZR65FA– – • – – • – – ZR80FA– – • – – • – – ZR100FA– – • – – • – – ZR125FA– – • – – • – – ZR150FA– – • – – • – – ZR200FA

Page 160: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-9

Rotary valves

2

3

4

5

6

7

8

10

9

11

12

13

14

For heating systems; hot/cold water quality VDI2035; glycol water mixture 50%.

Four-way rotary valve PN6, compact

Valve series V5442A

Valve type 4-way rotary mixing, compact

Medium type water

Materials body cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 110 oC

Pressure rating PN6

Port connection internal threads

Max. delta P 100 kPa

Torque for max. delta P 7 Nm

DN size Kvs value Typemm

20 4 V5442A102220 6,3 V5442A103025 10 V5442A104832 16 V5442A1055

M60

63A1

003

M60

63A4

007

M60

63L1

009

M60

63L4

003

3-pt 3-pt 3-pt 3-pt Control input signal24; 3 24; 3 230; 3 230; 3 Power supply [Vac; VA]

• • • • V5442A1022• • • • V5442A1030• • • • V5442A1048• • • • V5442A1055

Page 161: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-10

Rotary valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For hot/cold water quality VDI2035; glycol water mixture 50%.

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.

Four-way rotary valve PN6, compact, chrome plated

Valve series V5442G

Valve type 4-way rotary mixing, compact

Medium type water

Materials body chrome plated cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 110 oC

Pressure rating PN6

Port connection internal threads

Max. delta P 100 kPa

Torque for max. delta P 7 Nm

DN size Kvs value Typemm

20 4 V5442G100320 6,3 V5442G101125 10 V5442G102932 16 V5442G1037

M60

63A1

003

M60

63A4

007

M60

63L1

009

M60

63L4

003

3-pt 3-pt 3-pt 3-pt Control input signal24; 3 24; 3 230; 3 230; 3 Power supply [Vac; VA]

• • • • V5442G1003• • • • V5442G1011• • • • V5442G1029• • • • V5442G1037

Three-way rotary valve PN10

Valve series DRU

Valve type 3-way rotary mixing, bypass

Medium type water

Materials body cast iron, inner parts chrome plated

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 130 oC

Pressure rating PN10

Port connection external threads

Max. delta P 100 kPa

Page 162: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-11

Rotary valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Universal Rotary Valve

H-extensions

Accessories

DN size Kvs value Torque for max. delta P Typemm Nm

25 2,5 10 DRU25-2.525 4 10 DRU25-4.025 6,3 10 DRU25-6.325 10 10 DRU25-1025 16 10 DRU25-1632 10 20 DRU32-1032 16 20 DRU32-1632 25 20 DRU32-25

H-extension DN25 HE25

H-extension DN32 HE32

Welding socket with gaskets and cap nut, DN25, pipe size 25 mm WTU25

Welding socket with gaskets and cap nut, DN32, pipe size 32 mm WTU32

Soldering socket witch gasket and cap nut, DN25, pipe size 18 mm LSU25-18

Soldering socket witch gasket and cap nut, DN25, pipe size 22 mm LSU25-22

Soldering socket witch gasket and cap nut, DN25, pipe size 28 mm LSU25-28

Soldering socket witch gasket and cap nut, DN32, pipe size 22 mm LSU32-22

Soldering socket witch gasket and cap nut, DN32, pipe size 28 mm LSU32-28

Soldering socket witch gasket and cap nut, DN32, pipe size 35 mm LSU32-35

Internal threaded socket with gaskets and cap nut, DN25, pipe size 25 mm STU25

Internal threaded socket with gaskets and cap nut, DN32, pipe size 32 mm STU32

M60

61A1

013

M60

61A1

021

M60

61L1

019

M60

61L1

027

M70

61E1

012

M70

61E1

020

3-pt 3-pt 3-pt 3-pt 0/2..10V= 0/2..10V= Control input signal24; 3,5 24; 3,5 230; 3,5 230; 3,5 24; 2,4 24; 2,4 Power supply [Vac; VA]

10 20 10 20 10 20 Torque [Nm]

• – • – • – DRU25-2.5• – • – • – DRU25-4.0• – • – • – DRU25-6.3• – • – • – DRU25-10• – • – • – DRU25-16– • – • – • DRU32-10– • – • – • DRU32-16– • – • – • DRU32-25

Page 163: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

6-12

Rotary valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.For applications with sludge deposition and for panel heating (e.g. underfloor and ceiling heating systems) with oxygen diffusion.

H-extensions

Accessories

Three-way rotary valve PN10, for systems with oxygen diffusion

Valve type 3-way rotary mixing, bypass

Medium type water

Materials body red brass, inner parts chrome plated cast iron

Packing double O-ring sealing

Angle of rotation 90 o

Media temp. 2 ... 130 oC

Pressure rating PN10

Port connection external threads

DN size 25 mm

Max. delta P 100 kPa

Torque for max. delta P 10 Nm

Additional description Thermal insulation package included.

Kvs value Type2,5 DRR25-2.5

4 DRR25-4.06,3 DRR25-6.310 DRR25-1016 DRR25-16

H-extension DN25 HE25

Welding socket with gaskets and cap nut, DN25, pipe size 25 mm WTU25

Soldering socket witch gasket and cap nut, DN25, pipe size 18 mm LSU25-18

Soldering socket witch gasket and cap nut, DN25, pipe size 22 mm LSU25-22

Soldering socket witch gasket and cap nut, DN25, pipe size 28 mm LSU25-28

Internal threaded socket with gaskets and cap nut, DN25, pipe size 25 mm STU25

M60

61A1

013

M60

61L1

019

M70

61E1

012

3-pt 3-pt 0/2..10V= Control input signal24; 3,5 230; 3,5 24; 2,4 Power supply [Vac; VA]

10 10 10 Torque [Nm]

• • • DRR25-2.5• • • DRR25-4.0• • • DRR25-6.3• • • DRR25-10• • • DRR25-16

Page 164: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Frequency inverters Page

Frequency Inverters 7-2Parts and accessories for inverters 7-11

Page 165: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Frequency Inverters

7-2 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Frequency Inverters

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).

Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Features • Start up wizard• Integrated RFI-filters• Flexible side by side mounting with screws or DIN-rail as

standard• Compact size• Single rating suitable for both pump and fan or machine

applications• Maximum ambient temperature 50 oC;

(40 oC for COMP230-2P2-20 and COMP400-5P5-20)• Easy to use single software package with high functionality• Parameter upload/download even without powering the

inverter with COMP-LOADER accessory• Configurable Inputs and Outputs• Inputs/Outputs: 2 analog inputs (1 voltage + 1 current),

6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU

Series SmartDrive Compact

RFI-filter integrated

Output frequency 0 ... 320 Hz

Frequency resolution 0,01 Hz

Serial communication Modbus RTU

Immunity fulfills all EMC immunity requirements

Emissions EN61800-3 (category C2), C-Tick

Safety EN61800-5, CE, UL, cUL

Protection class IP20

More Information http://inverter.ecc.emea.honeywell.com

Page 166: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-3

Frequency Inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

208..240V, 1 phase

380..480V, 3 phases

Voltage Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brakechopper

1 phaseinput

3 phasesinput

Type

kW A kW A

230V 0,37 2,4 0,37 2,4 – • – COMP230-P37-20230V 0,75 3,7 0,75 3,7 – • – COMP230-P75-20230V 1,1 4,8 1,1 4,8 – • – COMP230-1P1-20230V 1,5 7 1,5 7 – • – COMP230-1P5-20230V 2,2 9,6 2,2 9,6 – • – COMP230-2P2-20

Voltage Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brakechopper

1 phaseinput

3 phasesinput

Type

kW A kW A

400V 0,55 1,9 0,55 1,9 – – • COMP400-P55-20400V 0,75 2,4 0,75 2,4 – – • COMP400-P75-20400V 1,1 3,3 1,1 3,3 – – • COMP400-1P1-20400V 1,5 4,3 1,5 4,3 integrated – • COMP400-1P5-20400V 2,2 5,6 2,2 5,6 integrated – • COMP400-2P2-20400V 3 7,6 3 7,6 integrated – • COMP400-3P0-20400V 4 9 4 9 integrated – • COMP400-4P0-20400V 5,5 12 5,5 12 integrated – • COMP400-5P5-20

Page 167: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Frequency Inverters

7-4 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant. The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.

Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Features • Detachable multilanguage HMI with text display as standard• Compact size • Integrated stress removal and 360o grounding for power cable

shield inside the device no need for cable glands• Varnished circuit boards as standard• Real Time Clock for timed functions and fault time stamps• Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2

relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)

• Flexible I/O configuration: 2 free slots for expansion boards • Start Up wizard for extremely fast start of basic pump and fan

applications• Mini wizards for more advanced applications: PID, Cascade

Control and Resonance sweep wizards• Intelligent automatic functionality: Ramp Time Optimizer,

Overtemperature ride-through, Power ride-through etc.• PID controller with advanced features: Sleep mode, Pump Soft

fill, pressure loss compensation, Cascade controller etc.

Series SmartDrive HVAC

RFI-filter integrated

Voltage 400V

Output frequency 0 ... 320 Hz

Frequency resolution 0,01 Hz

Serial communication Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks

Immunity fulfills all EMC immunity requirements

Emissions EN61800-3 (category C2), EN61000-3-12

Safety EN61800-5, CE, UL, cUL

1 phase input no

3 phases input yes

Optional functions add -A to the listed type numbers below to get the product with advanced commissioning HMI (keypad)

More Information http://inverter.ecc.emea.honeywell.com

Page 168: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-5

Frequency Inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

IP21

IP54

Protection class Low overload (for Fan/Pump) Low overload Icont TypekW A

IP21 1,1 3,4 HVAC400-1P1-21IP21 1,5 4,8 HVAC400-1P5-21IP21 2,2 5,6 HVAC400-2P2-21IP21 3 8 HVAC400-3P0-21IP21 4 9,6 HVAC400-4P0-21IP21 5,5 12 HVAC400-5P5-21IP21 7,5 16 HVAC400-7P5-21IP21 11 23 HVAC400-11P-21IP21 15 31 HVAC400-15P-21IP21 18,5 38 HVAC400-18P-21IP21 22 46 HVAC400-22P-21IP21 30 61 HVAC400-30P-21IP21 37 72 HVAC400-37P-21IP21 45 87 HVAC400-45P-21IP21 55 105 HVAC400-55P-21IP21 75 140 HVAC400-75P-21IP21 90 170 HVAC400-90P-21IP21 110 205 HVAC400-110-21IP21 132 261 HVAC400-132-21IP21 160 310 HVAC400-160-21

Protection class Low overload (for Fan/Pump) Low overload Icont TypekW A

IP54 1,1 3,4 HVAC400-1P1-54IP54 1,5 4,8 HVAC400-1P5-54IP54 2,2 5,6 HVAC400-2P2-54IP54 3 8 HVAC400-3P0-54IP54 4 9,6 HVAC400-4P0-54IP54 5,5 12 HVAC400-5P5-54IP54 7,5 16 HVAC400-7P5-54IP54 11 23 HVAC400-11P-54IP54 15 31 HVAC400-15P-54IP54 18,5 38 HVAC400-18P-54IP54 22 46 HVAC400-22P-54IP54 30 61 HVAC400-30P-54IP54 37 72 HVAC400-37P-54IP54 45 87 HVAC400-45P-54IP54 55 105 HVAC400-55P-54IP54 75 140 HVAC400-75P-54IP54 90 170 HVAC400-90P-54IP54 110 205 HVAC400-110-54IP54 132 261 HVAC400-132-54IP54 160 310 HVAC400-160-54

Page 169: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Frequency Inverters

7-6 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.

Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Features • the software is tailored to meet the typical HVAC application • start-up wizard• optimized I/O configuration including thermistor input• flexible I/O configuration: 2 slots• inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays,

1 thermistor input, 1 analog output

Series NXL HVAC

RFI-filter integrated

Brake chopper integrated

Voltage 400V

Output frequency 0 ... 320 Hz

Frequency resolution 0,01 Hz

Serial communication Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen

Immunity fulfills all EMC immunity requirements

Emissions EN61800-3 (IP21: category C2, IP54: category C1)

Safety EN61800-5, CE, UL, cUL

1 phase input no

3 phases input yes

More Information http://inverter.ecc.emea.honeywell.com

Page 170: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-7

Frequency Inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

IP21

IP54

Protection class Low overload(for Fan/Pump)

Low overload Icont High overload(for Machines)

High overload Icont Type

kW A kW A

IP21 1,1 3,3 0,75 2,2 HVAC03C2IP21 1,5 4,3 1,1 3,3 HVAC04C2IP21 2,2 5,6 1,5 4,3 HVAC05C2IP21 3 7,6 2,2 5,6 HVAC07C2IP21 4 9 3 7,6 HVAC09C2IP21 5,5 12 4 9 HVAC12C2IP21 7,5 16 5,5 12 HVAC16C2IP21 11 23 7,5 16 HVAC23C2IP21 15 31 11 23 HVAC31C2IP21 18,5 38 15 31 HVAC38C2IP21 22 46 18,5 38 HVAC46C2IP21 30 61 22 46 HVAC61C2

Protection class Low overload(for Fan/Pump)

Low overload Icont High overload(for Machines)

High overload Icont Type

kW A kW A

IP54 1,1 3,3 0,75 2,2 HVAC03C5IP54 1,5 4,3 1,1 3,3 HVAC04C5IP54 2,2 5,6 1,5 4,3 HVAC05C5IP54 3 7,6 2,2 5,6 HVAC07C5IP54 4 9 3 7,6 HVAC09C5IP54 5,5 12 4 9 HVAC12C5IP54 7,5 16 5,5 12 HVAC16C5IP54 11 23 7,5 16 HVAC23C5IP54 15 31 11 23 HVAC31C5IP54 18,5 38 15 31 HVAC38C5IP54 22 46 18,5 38 HVAC46C5IP54 30 61 22 46 HVAC61C5

Page 171: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Frequency Inverters

7-8 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Speed and/or torque controller for induction motors. EMC and LVD compliant with external filters.The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating, ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.

208..240V, 1/3 phases

380..500V, 3 phases

NXL Compact RFI filters (EN61800-3 category C2)

Inverters 0,37..2,2kW, IP20, NXL Compact

Features • 1 all-round software package included• start-up wizard• flexible I/O configuration; 1 free slot• inputs/outputs: 2 analog inputs, 3 digital inputs, 1 relay,

1 analog output

Series NXL Compact

RFI-filter optional

Output frequency 0 ... 320 Hz

Frequency resolution 0,01 Hz

Serial communication Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen

Immunity fulfills all EMC immunity requirements

Emissions EN61800-3 (category C2) with optional filters

Safety EN61800-5, CE, UL, cUL

Protection class IP20

Voltage Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brakechopper

1 phaseinput

3 phasesinput

Type

kW A kW A

230V 0,37 2,4 0,25 1,7 – • – NXL0002V32C1N0230V 0,75 3,7 0,55 2,8 integrated • • NXL0003V32C1N1230V 1,1 4,8 0,75 3,7 integrated • • NXL0004V32C1N1230V 1,5 6,6 1,1 4,8 integrated • • NXL0006V32C1N1

Voltage Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brakechopper

1 phaseinput

3 phasesinput

Type

kW A kW A

400V 0,55 1,9 0,37 1,3 – – • NXL0001V35C1N0400V 0,75 2,4 0,55 1,9 – – • NXL0002V35C1N0400V 1,1 3,3 0,75 2,4 integrated – • NXL0003V35C1N1400V 1,5 4,3 1,1 3,3 integrated – • NXL0004V35C1N1400V 2,2 5,4 1,5 4,3 integrated – • NXL0005V35C1N1

RFI filter (1 phase input)for 208..240V models; H-level NXLRFIV12

RFI filter for 380..500V models; H-level NXLRFIV35

Page 172: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-9

Frequency Inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick

Inverters 1,1..400kW, IP21/IP54, NXS

Features • high featured software package with predefined applications• start-up wizard• detachable multilingual HMI-panel with memory and backup

functions• flexible I/O configuration; 5 slots• inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays,

1 digital output, 1 thermistor input, 1 analog output

Series NXS

Voltage 400V

Output frequency 0 ... 320 Hz

Frequency resolution 0,01 Hz

Serial communication optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen

Immunity fulfills all EMC immunity requirements

Safety EN61800-5, CE, UL, cUL

RFI-filter integrated

1 phase input no

3 phases input yes

More Information http://inverter.ecc.emea.honeywell.com

Protection class Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brake chopper Type

kW A kW A

IP21 1,1 3,1 0,75 2,2 integrated NXS0003V35A2H1IP21 1,5 4 1,1 3,1 integrated NXS0004V35A2H1IP21 2,2 5,4 1,5 4 integrated NXS0005V35A2H1IP21 3 7 2,2 5,4 integrated NXS0007V35A2H1IP21 4 9 3 7 integrated NXS0009V35A2H1IP21 5,5 12 4 9 integrated NXS0012V35A2H1IP21 7,5 16 5,5 12 integrated NXS0016V35A2H1IP21 11 22 7,5 16 integrated NXS0022V35A2H1IP21 15 31 11 22 integrated NXS0031V35A2H1IP21 18,5 38 15 31 integrated NXS0038V35A2H1IP21 22 45 18,5 38 integrated NXS0045V35A2H1IP21 30 61 22 45 integrated NXS0061V35A2H1IP21 37 72 30 61 optional NXS0072V35A2H0IP21 45 87 37 72 optional NXS0087V35A2H0IP21 55 105 45 87 optional NXS0105V35A2H0IP21 75 140 55 105 optional NXS0140V35A2H0IP21 90 170 75 140 optional NXS0168V35A2H0IP21 110 205 90 170 optional NXS0205V35A2H0IP21 132 261 110 205 optional NXS0260V35A2H0IP21 160 300 132 245 optional NXS0310V35A2H0

Page 173: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Frequency Inverters

7-10 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

IP21, stand-alone cabinet; Emissions EN61800-3 (category 3)

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick

Protection class Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brake chopper Type

kW A kW A

IP21 200 385 160 300 – NXS0385V35A2L0IP21 250 460 200 385 – NXS0460V35A2L0IP21 315 590 250 520 – NXS0590V35A2L0IP21 355 650 315 590 – NXS0650V35A2L0IP21 400 730 355 650 – NXS0730V35A2L0

Protection class Low overload(for Fan/Pump)

Low overloadIcont

High overload(for Machines)

High overloadIcont

Brake chopper Type

kW A kW A

IP54 1,1 3,1 0,75 2,2 integrated NXS0003V35A5H1IP54 1,5 4 1,1 3,1 integrated NXS0004V35A5H1IP54 2,2 5,4 1,5 4 integrated NXS0005V35A5H1IP54 3 7 2,2 5,4 integrated NXS0007V35A5H1IP54 4 9 3 7 integrated NXS0009V35A5H1IP54 5,5 12 4 9 integrated NXS0012V35A5H1IP54 7,5 16 5,5 12 integrated NXS0016V35A5H1IP54 11 22 7,5 16 integrated NXS0022V35A5H1IP54 15 31 11 22 integrated NXS0031V35A5H1IP54 18,5 38 15 31 integrated NXS0038V35A5H1IP54 22 45 18,5 38 integrated NXS0045V35A5H1IP54 30 61 22 45 integrated NXS0061V35A5H1IP54 37 72 30 61 optional NXS0072V35A5H0IP54 45 87 37 72 optional NXS0087V35A5H0IP54 55 105 45 87 optional NXS0105V35A5H0IP54 75 140 55 105 optional NXS0140V35A5H0IP54 90 170 75 140 optional NXS0168V35A5H0IP54 110 205 90 170 optional NXS0205V35A5H0IP54 132 261 110 205 optional NXS0260V35A5H0IP54 160 300 132 245 optional NXS0310V35A5H0

Page 174: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-11

Parts and accessories for inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.Fieldbus cards

Input/output expander cards

SmartDrive PC connection tools and cables

NXL/NXS PC connection tools and cables

Parts and accessories for inverters

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeLonWorks • • • – OPTC4

Modbus/N2 (RS485) – • – – NXOPTC2Profibus DP • • – – NXOPTC3

CANopen (slave) • • – – NXOPTC6DeviceNet • • – – NXOPTC7

Modbus TCP/IP (Ethernet) • • – – NXOPTCIBACnet MS/TP (RS485) • • – – NXOPTCJ

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact Type6 digital inputs/outputs (programmable) – • • – OPTB1

1 analog input (mA), 2 analog output (mA) • • • – OPTB43 relays (NO) • • • – OPTB5

1 relay, 5 Vac inputs (42..240 Vac) – • • – OPTB91 analog input (mA/V), 1 relay (NO),

1 digital output (open collector)– – • – OPTBF

3 digital inputs, 1 relay (NO/NC),1 digital output

• – – – NXLOPTAA

standard NXS slot A board: 6 DI,1 DO (open collector), 2 AI, 1 AO

– • – – NXOPTA1

2 relays (1 NO, 1 NO/NC), 1 thermistor • • – – NXOPTB23 Pt100 input – • – – NXOPTB8

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeSmartDrive Compact Parameter download/upload and PC interface tool with cable for

USB connection to PC

– – – • COMP-LOADER

SmartDrive Compact Parameter download/upload and PC interface tool without cable

– – – • COMP-LOADER-NC

SmartDrive 3.0m USB PC connection cable – – • • SMARTDRIVE-USBC

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeNXL RS232 adapter (for PC connection) • – – – NXLPANRS

2 m RS232 cable • • – – RS232C2M4 m RS232 cable • • – – RS232C-4M

Page 175: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Parts and accessories for inverters

7-12 http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

SmartDrive HVAC display panels

NXL Display panels

NXS Display panels

Display panel kits

SmartDrive COMPACT IP20 to IP21 upgrade kits

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeSmartDrive HVAC standard text

display/keypad– – • – HVAC-HMI-S

SmartDrive HVAC advanced commissioningdisplay/keypad with parameter copy

function

– – • – HVAC-HMI-A

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeNXL standard 7-segment display • – – – NXLPANC

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeNXS standard alpha-numeric display – • – – NXPANA

NXS special display for Cyrillic orChinese letters

– • – – NXPANG

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeNXL door installation set for display panel,

2m cable• – – – DRA-02L

NXL door installation set for display panel,4m cable

• – – – DRA-04L

NXS door installation set for display panel,2m cable

– • – – DRA02B

NXS door installation set for display panel,4m cable

– • – – DRA-04B

SmartDrive HVAC door installation set fordisplay panel, 3m cable

– – • – HVAC-DOOR-KIT

SmartDrive HVAC hand held kit for displaypanel, 3m cable

– – • – HVAC-HAND-KIT

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeIP21 enclosure upgrade kit for SmartDrive

Compact size MI1– – • – COMP-IP21-KIT1

IP21 enclosure upgrade kit for SmartDriveCompact size MI2

– – • – COMP-IP21-KIT2

IP21 enclosure upgrade kit for SmartDriveCompact size MI3

– – • – COMP-IP21-KIT3

IP21 enclosure upgrade kit with additionalwiring terminal cover for SmartDrive

Compact size MI1

– – • – COMP-NEMA1-KIT1

IP21 enclosure upgrade kit with additionalwiring terminal cover for SmartDrive

Compact size MI2

– – • – COMP-NEMA1-KIT2

IP21 enclosure upgrade kit with additionalwiring terminal cover for SmartDrive

Compact size MI3

– – • – COMP-NEMA1-KIT3

Page 176: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-13

Parts and accessories for inverters

2

3

4

5

6

7

8

10

9

11

12

13

14

NXL HVAC/NXS IP21 to IP54 upgrade kits

NXL/NXS Sine-wave output filters 380-500V, IP00 Selection to be done so that the nominal current of the inverter cannot exceed the nominal current of the filter

Main cooling fan spare parts for inverters

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeIP54 enclosure upgrade kit for NXL

HVAC/NXS size 4 (HVAC03-HVAC12,NXS0003-NXS0012)

• • – – NXIP54FR4

IP54 enclosure upgrade kit for NXLHVAC/NXS size 5 (HVAC16-HVAC31,

NXS0016-NXS0031)

• • – – NXIP54FR5

IP54 enclosure upgrade kit for NXLHVAC/NXS size 6 (HVAC38-HVAC61,

NXS0038-NXS0061)

• • – – NXIP54FR6

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeFilter for Nominal current of 10 A (40oC),

8,8 A (50oC)• • – – SIN-0010-5-0-P

Filter for Nominal current of 18 A (40oC), 16A (50oC)

• • – – SIN-0018-5-0-P

Filter for Nominal current of 32 A (40oC), 28A (50oC)

• • – – SIN-0032-5-0-P

Filter for Nominal current of 48 A (40oC), 42A (50oC)

• • – – SIN-0048-5-0-P

Filter for Nominal current of 75 A (40oC), 66A (50oC)

• • – – SIN-0075-5-0-P

Filter for Nominal current of 110 A (40oC),97 A (50oC)

• • – – SIN-0110-5-0-P

Filter for Nominal current of 180 A (40oC),155 A (50oC)

• • – – SIN-0180-5-0-P

Product description NXL HVAC NXS SmartDrive HVAC SmartDrive Compact TypeNXL HVAC / NXS spare part fan size 4

(HVAC03-HVAC12, NXS0003-NXS0012)• • – – NX-FAN-4

NXL HVAC / NXS spare part fan size 5(HVAC16-HVAC31, NXS0016-NXS0031)

• • – – NX-FAN-5

NXL HVAC / NXS spare part fan size 6(HVAC38-HVAC61, NXS0038-NXS0061)

• • – – NX-FAN-6

NXS spare part fan size 7(NXS0072-NXS0105)

– • – – NX-FAN-7

SmartDrive HVAC spare part fan size 4(HVAC400-1P1..HVAC400-5P5)

– – • – HVAC-FAN-4

SmartDrive HVAC spare part fan size 5(HVAC400-7P5..HVAC400-15P)

– – • – HVAC-FAN-5

SmartDrive HVAC spare part fan size 6(HVAC400-18P..HVAC400-30P)

– – • – HVAC-FAN-6

SmartDrive HVAC spare part fan size 7(HVAC400-37P..HVAC400-55P)

– – • – HVAC-FAN-7

Page 177: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

7-14 http://products.ecc.emea.honeywell.com/europe

Page 178: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Sensors Page

CentraLine Sensors 8-2Temperature sensors NTC 8-5Temperature sensors Pt100/Pt1000 8-11R.H. ( + temperature) sensors 8-15IRC/XL10 sensors, Wall modules 8-17Pressure switches 8-21Pressure sensors 8-29Air quality sensors 8-36Miscellaneous 8-38

Page 179: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-2

CentraLine Sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

CentraLine Sensors

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.

Accessories

CentraLine air quality sensor

Protection class IP30

Output signal 0..10Vdc

Power supply 24 Vacdc; 1 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 104 mm; 33 mm

LED functions air quality indication

Additional description Adjustable output offset.

TypeCLCMNA172B

CentraLine room temperature/ CO2 sensor

Protection class IP30

Output signal the following CO2 output signals are applicable, analog or digital• 0..10V for 0..2000 ppm (factory setting)• 0..10 V or 2..10 V for 0..2000 ppm or 0..3000 ppm (configurable)• digital output with adjustable CO2 setpoint and hysteresis for

ventilation on/off

Power supply 24 Vacdc; 2,8 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 104 mm; 33 mm

Temperatureelement

Temperaturerange

Setpointknob

Extra setp.knob

Occupancyswitch

Wiringterminals

LEDfunctions

Type

oC K oC

– – – – – 3 CO2 indicator CLCM1C155NTC20k 6 ... 40 -5 ... 5 12 ... 30 auto/bypass 7 occupancy CLCM4C155

Blind covers for setpoint wheel to prevent unauthorized setpoint changes (25 pieces) WMSPS-2

PC interface cable (PC software on request) HDI10

Page 180: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-3

CentraLine Sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

CentraLine room temperature sensors

Protection class IP30

Temperature element NTC20k

Mounting place internal wall

Housing (HxWxD) 104 mm; 104 mm; 33 mm

Temperaturerange

Setpointknob

Extra setp.knob

Occupancyswitch

Fanswitch

Wiringterminals

LEDfunctions

Note Type

oC K oC

6 ... 40 – – – – 2 – – CLCM1T11N6 ... 40 -5 ... 5 12 ... 30 – – 3 – – CLCM2T11N

-15 ... 40 -7 ... 7 – auto/off/on – 5 errorindication

not forSERVAL

CLCM3T111

6 ... 40 -5 ... 5 12 ... 30 auto/bypass – 7 – – CLCM4T1116 ... 40 -5 ... 5 12 ... 30 auto/bypass auto/off/on 7 – – CLCM5T1116 ... 40 -5 ... 5 12 ... 30 auto/bypass auto/off/1/2/3 7 – – CLCM6T111

Blind covers for setpoint wheel to prevent unauthorized setpoint changes (25 pieces) WMSPS-2

CentraLine room temperature/R.H. sensor

Protection class IP30

Temperature element NTC20k

Temperature range 6 ... 40 oC

R.H. range 20 ... 95 %rh

R.H. sensing element capacitive

R.H. output signal 0..10V=

Power supply 24 Vacdc; 0,15 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 104 mm; 33 mm

Wiring terminals 4

Additional description central override of setpoint

TypeCLCM1H112

Page 181: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-4

CentraLine Sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature sensor with digital display. Model with R.H.-sensor.

CentraLine room temperature/R.H. sensor, with display

Display functions room temperature, setpoint temperature, occupancy status, fan speed status, humidity

Protection class IP30

Temperature element NTC20k

Temperature range 6 ... 40 oC

Setpoint knob -5 ... 5 K

Extra setp. knob 12 ... 30 oC

Occupancy switch on/off

Fan switch auto/off/1/2/3

Power supply 24 Vac; 0,5 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 104 mm; 33 mm

Additional description Tool-free configuration:• number of fan speeds• relative / absolute setpoint• enable/disable space temperature display• central override of setpoint and fan speed

R.H. range R.H. sensing element R.H. output signal Wiring terminals Type%rh

– – – 7 CLCM6T21N10/15/20 ... 95 capacitive 0..10V= 8 CLCM6H212

Blind covers for setpoint wheel to prevent unauthorized setpoint changes (25 pieces) WMSPS-2

Page 182: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-5

Temperature sensors NTC

2

3

4

5

6

7

8

10

9

11

12

13

14

Temperature sensors NTC

Room temperature sensor for Excel 10 and Excel 50..800 controllers. With setpoint adjustment, occupancy extension.

Wall modules for heating applications

LED functions LED on or blinking in case of bypass, LED functions programmable with Excel 20..800 controllers

Temperature element NTC20k

Temperature range -15 ... 40 oC

Setpoint knob -7 ... 7 oC

Occupancy switch auto/off/on

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Models with setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.

Product description TypeSensor with setpoint wheel TF22

Product description TypeSensor with pushbuttons for setpoint adjustment and display TFU22

Room temperature sensor NTC, economy

Protection class IP30

Temperature element NTC20k

Temperature range 6 ... 40 oC

Mounting place internal wall

Housing (HxWxD) 56 mm; 46 mm; 19,3 mm

Wiring terminals 2

Type of terminals spring

Additional description T7470A1009 will be delivered as one set of 5 sensors.

TypeT7470A1009

Room temperature sensor, NTC

Protection class IP30

Temperature range 10 ... 40 oC

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Temperature element Wiring terminals TypeNTC20k 2 RF20

2 x NTC20k 3 DRF20-S

Page 183: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-6

Temperature sensors NTC

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature sensor. Models with remote control point adjustment unit.

Room temperature sensor, setpoint unit, IRC style

Protection class IP30

Mounting place internal wall

Temperature element NTC20k

Temperature range 0 ... 50 oC

Housing (HxWxD) 130 mm; 80 mm; 34 mm

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

2 – – – T7412A1000

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

3 - ... + – – T7412B1008

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

4 - ... + on/off – T7412C1006

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

4 - ... + – auto/off/1/2/3 T7412D1004

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

5 – – – T7412E1027

Page 184: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-7

Temperature sensors NTC

2

3

4

5

6

7

8

10

9

11

12

13

14

Water temperature sensor with well or strap-on.

Immersion with well

Strap-on

Sensor for direct mounting in pipe, G1/2" connection.For water temperature measurement in district heating or hot water supply.

Water temperature sensor, NTC

Wiring terminals 2

Temperatureelement

Temperaturerange

Mountingplace

Immersionwell material

Immersionwell thread

Immersiondepth

Protectionclass

Type

oC mm

NTC10k -25 ... 130 in pipe brass R1/2" 135 IP54 VF10TNTC20k -25 ... 130 in pipe brass R1/2" 135 IP52 VF20TNTC20k -25 ... 150 in pipe stainless steel R1/2" 135 IP52 VF20NTNTC20k -25 ... 130 in pipe brass R1/2" 300 IP52 VF20LNTC20k -25 ... 150 in pipe stainless steel R1/2" 300 IP52 VF20LN

Temperatureelement

Temperaturerange

Mountingplace

Immersionwell material

Immersionwell thread

Immersiondepth

Protectionclass

Type

oC mm

NTC10k 0 ... 110 strap on pipe – – – IP54 VF10ANTC20k 0 ... 110 strap on pipe – – – IP30 VF20A

Water temperature sensor NTC, fast reaction time

Protection class IP65

Temperature element NTC20k fast

Temperature range -20 ... 140 oC

Mounting place in pipe

Cable length 2,5 m

Additional description Reaction time max. 2 sec. Sensing material steel 1.4571. Immersion depth adjustable.

Immersion depth Sensing element (dia x L) Typemm mm; mm

max. 75 4; 25 T7425A1005max. 220 4; 170 T7425A1013max. 300 4; 250 T7425A1021

Page 185: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-8

Temperature sensors NTC

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Watertight temperature sensor with sensor cartridge.

Wells

Water temperature sensor NTC, cable type

Protection class IP64

Temperature range -20 ... 100 oC

Mounting place universal

Immersion depth min. 50 mm

Applicable well length 135 mm

Sensing element (dia x L) 6,5 mm; 50 mm

Cable length 2 m

Additional description KTF20-B (bulk of 50 sensors of Type KTF20)

Temperature element Wiring terminals TypeNTC20k 2 KTF20NTC20k 2 KTF20-B

2 x NTC20k 3 DKF20

Brass well 135 mm R1/2" VFHT

Steel well 135 mm R1/2" VFNT

Outdoor, strap-on temperature sensor

Mounting place outdoor/strap-on

Protection class IP65

Temperature range -30 ... 70 oC

Temperature element NTC20k

Cable length 1 m

TypeT7414C1012

Outdoor temperature sensor NTC

Mounting place wall outside

Wiring terminals 2

Temperature element Temperature range Housing (HxWxD) Protection class TypeoC mm; mm; mm

NTC20k -30 ... 60 95; 65; 70 IP30 AF20

Page 186: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-9

Temperature sensors NTC

2

3

4

5

6

7

8

10

9

11

12

13

14

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.For application in ducts where large temperature gradients can occur.

Temperature element Temperature range Housing (HxWxD) Protection class TypeoC mm; mm; mm

NTC10k -40 ... 70 72; 49; 37 IP54 T7416A1030NTC20k -40 ... 70 72; 49; 37 IP54 T7416A1022

Air duct temperature sensor, NTC

Temperature range -40 ... 80 oC

Mounting place air duct

Immersion depth 300 mm

Wiring terminals 2

Additional description Humidity 5..95 %rh, non condensing.

Temperature element Cable length Protection class Typem

NTC10k – IP54 LF10NTC20k – IP30 LF20

Temperature element Cable length Protection class Typem

NTC20k 5 IP65 LF20-C

Air duct temperature sensor, average measurement

Temperature element 4 x NTC20k

Temperature range -30 ... 70 oC

Mounting place air duct

Wiring terminals 2

Additional description The 3 meters flexible rod has four sensors positioned along the length of the rod.

TypeC7085A1014

Page 187: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-10

Temperature sensors NTC

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Temperature sensor for air handling units, fancoil units or air outlets.

For use in greenhouses and similar applications

for use in greenhouses and similar applications

Unit temperature sensor

Protection class IP54

Mounting place air duct

Temperature range 0 ... 70 oC

Wiring terminals 2

Additional description Sensor supplied with mounting bracket. Sensing element size: diameter 10 mm, length 50 mm.

Temperature element Cable length Typem

NTC10k 1,5 C7068A1030NTC20k 1,5 C7068A1007NTC20k 5 C7068A1007-5M

Earth temperature sensor, NTC

Protection class IP62

Temperature element NTC20k

Temperature range -20 ... 34 oC

Mounting place greenhouse, earth

Wiring terminals 2

Cable length 5 m

TypeEF20

Damp-proof temperature sensor, NTC

Approvals IEC144

Protection class IP30

Temperature element NTC20k

Temperature range -20 ... 30 oC

Mounting place greenhouse, air

Wiring terminals 2

Cable length 5 m

TypeGF20

Page 188: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-11

Temperature sensors Pt100/Pt1000

2

3

4

5

6

7

8

10

9

11

12

13

14

Temperature sensors Pt100/Pt1000

Room temperature sensor. Models with remote control point adjustment unit.

Water immersion temperature sensor with or without well.

Wells

Room temperature sensor Pt100/Pt1000, setpoint unit

Mounting place internal wall

Approvals IEC751 Class B

Protection class IP30

Temperature range 0 ... 50 oC

Housing (HxWxD) 130 mm; 80 mm; 34 mm

Temperature element Setpoint knob Wiring terminals TypeoC

Pt100 – 2 T7412A1059Pt1000 – 2 T7412A1018Pt1000 - ... + 4 T7412B1016Pt1000 -15 ... 30 5 T7412B1040

Water temperature sensor

Approvals IEC751 class B

Protection class IP54

Temperature element Pt1000

Wiring terminals 2

Temperaturerange

Mountingplace

Immersion wellmaterial

Immersion wellthread

Immersiondepth

Type

oC mm

-25 ... 130 in pipe brass R1/2" 135 T7413A1009-25 ... 150 in well – – max. 135 T7413A1041-25 ... 150 in well – – max. 300 T7413A1058

Brass well 135 mm R1/2" VFHT

Steel well 135 mm R1/2" VFNT

Brass well 300 mm R1/2" VFL

Steel well 300 mm R1/2" VFLN

Water temperature sensor, strap-on

Approvals IEC751 class B

Protection class IP54

Temperature element Pt1000

Temperature range 0 ... 110 oC

Mounting place strap on pipe

Wiring terminals 2

TypeT7414A1008

Page 189: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-12

Temperature sensors Pt100/Pt1000

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Sensor for direct mounting in pipe, G1/2" connection.For water temperature measurement in hot water supply, solar panels etc.

Water temperature sensor Pt1000, fast reaction time

Protection class IP65

Temperature element Pt1000 fast

Temperature range -20 ... 300 oC

Mounting place in pipe

Cable length 2,5 m

Additional description Reaction time max. 2 sec. Sensing material steel 1.4571. Immersion depth adjustable.

Immersion depth Sensing element (dia x L) Typemm mm; mm

max. 75 4; 75 T7425B1011max. 220 4; 220 T7425B1029

Water temperature sensor, cable type

Approvals IEC751 class B

Protection class IP54

Temperature element Pt1000

Mounting place universal

Immersion depth min. 50 mm

Applicable well length 135 mm

Sensing element (dia x L) 6 mm; 50 mm

Wiring terminals 2

Cable length 2,5 m

Temperature range TypeoC

-20 ... 100 T7415A1007-20 ... 300 T7415A1015

Brass well 135 mm R1/2" VFHT

Steel well 135 mm R1/2" VFNT

Page 190: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-13

Temperature sensors Pt100/Pt1000

2

3

4

5

6

7

8

10

9

11

12

13

14

Outdoor, strap-on temperature sensor

Approvals IEC751 class B

Protection class IP65

Temperature element Pt1000

Temperature range -30 ... 70 oC

Mounting place outdoor/strap-on

Wiring terminals 2

Cable length 1 m

TypeT7414C1004

Outdoor temperature sensor

Approvals IEC751 class B

Protection class IP54

Temperature element Pt1000

Temperature range -40 ... 70 oC

Mounting place wall outside

Housing (HxWxD) 72 mm; 49 mm; 37 mm

Wiring terminals 2

TypeT7416A1014

Air duct temperature sensor Pt100/Pt1000

Approvals IEC751 class B

Protection class IP54

Temperature range -40 ... 80 oC

Mounting place air duct

Wiring terminals 2

Temperature element Immersion depth Typemm

Pt100 135 T7411A1043Pt1000 135 T7411A1001Pt1000 300 T7411A1019

Page 191: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-14

Temperature sensors Pt100/Pt1000

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four rod clips with screws.For application in ducts where large temperature gradients can occur.

Steel plug in temperature sensor with mounting flange.For flue gas temperature measurement.

Air duct temperature sensor, average measurement

Temperature element 4 x Pt1000

Temperature range -30 ... 70 oC

Mounting place air duct

Wiring terminals 2

Additional description The 3 meters flexible rod has four sensors positioned along the length of the rod.

TypeC7085A1006

Flue gas temperature sensor

Temperature element Pt1000

Temperature range 0 ... 320 oC

Media temp. limit temperatures up to 400 oC are allowable for short periods

Mounting place flue gas vent

Immersion depth 120 mm

Cable length 1 m

Additional description Supplied with electrical cable with steel casing.

TypeAGF1

Page 192: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-15

R.H. ( + temperature) sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

R.H. ( + temperature) sensors

Combined Room Humidity and Temperature Sensor with various sensor elements

Wall module with temperature and R.H. sensor

Temperature element NTC20k

Temperature range 10 ... 40 oC

R.H. range 5 ... 90 %rh

R.H. sensing element capacitive

R.H. output signal 0..10V=

Power supply 24 Vacdc; 0,15 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Wiring terminals 5

TypeT7560C1006

Room R.H.- and temperature sensor

Approvals IEC751 class B for Pt1000 sensor

Protection class IP30

R.H. range 5 ... 95 %rh

R.H. sensing element capacitive

R.H. output signal 0..10V=

Power supply 24 Vac; 0,48 VA

Mounting place internal wall

Housing (HxWxD) 130 mm; 80 mm; 34 mm

Temperature element Output signal Temperature range TypeoC

– – – H7012A1009Pt1000 – 0 ... 50 H7012B1008NTC20k – 0 ... 50 H7012B1024

– temp: 0..10V= 0 ... 50 H7012B1030

Upgrade kit for H7012A1009 with Balco500 temperature sensor (5 sensors included) H7012BALCOKIT

Page 193: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-16

R.H. ( + temperature) sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Outdoor R.H.- and temperature sensor

Protection class IP34

Temperature range -30 ... 50 oC

R.H. range 5 ... 95 %rh

R.H. sensing element capacitive

R.H. output signal 0..1/10V=

Power supply 24 Vac; 0,48 VA

Mounting place wall outside

Housing (HxWxD) 172 mm; 132 mm; 60 mm

Wiring terminals 6

Additional description Relative humidity sensor accuracy 3%.

Temperature element TypePt1000 H7508A1026NTC10k H7508A1030NTC20k H7508A1042

Air duct R.H.- and temperature transmitter

Protection class IP65

Output signal • temperatue: 0..10 V• relative humidity: 0..10 V

R.H. range 0 ... 100 %rh

R.H. sensing element capacitive

Power supply 24 Vacdc; 0,4 VA

Mounting place air duct

Immersion depth 235 mm

Additional description Relative humidity sensor accuracy 2,5%.

Temperature range Wiring terminals Note TypeoC

0 ... 50 5 – H7015B1060-30 ... 70 7 extra output: NTC20k sensor H7015B1080

Page 194: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-17

IRC/XL10 sensors, Wall modules

2

3

4

5

6

7

8

10

9

11

12

13

14

IRC/XL10 sensors, Wall modules

Room temperature sensor. Models with remote control point adjustment unit.

Room temperature sensor, setpoint unit, IRC style

Protection class IP30

Mounting place internal wall

Temperature element NTC20k

Temperature range 0 ... 50 oC

Housing (HxWxD) 130 mm; 80 mm; 34 mm

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

2 – – – T7412A1000

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

3 - ... + – – T7412B1008

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

4 - ... + on/off – T7412C1006

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

4 - ... + – auto/off/1/2/3 T7412D1004

Wiring terminals Setpoint knob Occupancy switch Fan switch TypeoC

5 – – – T7412E1027

Page 195: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-18

IRC/XL10 sensors, Wall modules

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Remote setpoint adjustment unit.

Room temperature sensor for Excel 10/12 and Excel 50..800 controllers. Models available with setpoint adjustment, occupancy extension and fan switch.

Remote setpoint adjustment unit for IRC or XL10

Mounting fancoil unit

Protection class IP30

Setpoint knob - ... + oC

Cable length 2 m

Housing (HxWxD) 75 mm; 70 mm; 22 mm

Wiring terminals Fan switch Model Type2 – for XL IRC S7014A1004

Wiring terminals Fan switch Model Type3 auto/off/1/2/3 for XL IRC S7014B10003 auto/off/1/2/3 for XL10 S7014C1009

Wall modules for EXCEL 5000 controllers

LED functions LED on or blinking in case of bypass, LED functions programmable with Excel 20..800 controllers

Temperature element NTC20k

Temperature range 10 ... 35 oC

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Models with setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.

Setpoint knob Extra setp. knob Occupancy switch Fan switch TypeoC oC

– – – – T7460A1001-5 ... 5 12 ... 30 – – T7460B1009-5 ... 5 12 ... 30 auto/bypass – T7460C1007-5 ... 5 12 ... 30 – auto/off/1/2/3 T7460D1005-5 ... 5 12 ... 30 auto/bypass auto/off/on T7460E1002-5 ... 5 12 ... 30 auto/bypass auto/off/1/2/3 T7460F1000

LON connection board T7460LONJACK

Setpoint range limiter T7460LIMITER

Page 196: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-19

IRC/XL10 sensors, Wall modules

2

3

4

5

6

7

8

10

9

11

12

13

14

Spare parts for all T7460 models

Spare parts for T7460B,C,D,E,F

Spare parts for T7460D,E,F

Spare parts for T7460C,E,F

Blind cover, blue (25 pieces) WMSPS-1

Blind cover, white (25 pieces) WMSPS-2

Round knob, blue (25 pieces) WMSPS-3

Round knob, white (25 pieces) WMSPS-4

Setpoint wheel, blue (scale +/-5K) (25 pieces) WMSPS-8

Setpoint pack, consists of 1 blind cover white, 1 setpoint wheel blue (scale 12..30). 1 setpointwheel white (scale 12..30), 1 setpointwheel white, scale +/-5 (10 pieces)

WMSPS-9

Fanspeed knob (50 pieces) WMSPS-10

Occupancy button (50 pieces) WMSPS-11

Page 197: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-20

IRC/XL10 sensors, Wall modules

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Room temperature sensor with digital display, for Excel 10 and Excel 50..800 controllers. With setpoint adjustment, occupancy extension, fan speed button and on/off button. Model with R.H.-sensor.

Accessories

Spare parts

Wall modules for EXCEL 5000 controllers, with display

Display functions room temperature, setpoint temperature, occupancy status, fan speed status

Temperature element NTC20k

Temperature range 10 ... 40 oC

Setpoint knob -5 ... 5 oC

Extra setp. knob 12 ... 30 oC

Occupancy switch on/off

Fan switch configurable

Power supply 24 Vac; 2 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Tool-free configuration:• number of fan speeds• relative / absolute setpoint• enable/disable space temperature display• centigrade/fahrenheit

R.H. range R.H. sensing element R.H. output signal Wiring terminals Model Type%rh

– – – 7 blue knobs/wheel T7560A1000– – – 7 white knobs/wheel T7560A1026– – – 7 white knobs/wheel/

fahrenheitT7560A1018

5 ... 90 capacitive 0..10V= 8 blue knobs/wheel T7560B10085 ... 90 capacitive 0..10V= 8 white knobs/wheel T7560B10245 ... 90 capacitive 0..10V= 8 white knobs/wheel/

fahrenheitT7560B1016

LON/BACnet connection board T7460LONJACK

Blind cover for T7560 knobs (50 pieces) T7560BLINDS

Blind cover, blue (25 pieces) WMSPS-1

Blind cover, white (25 pieces) WMSPS-2

Round knob, blue (25 pieces) WMSPS-3

Round knob, white (25 pieces) WMSPS-4

Setpoint wheel, blue, unprinted (25 pieces) WMSPS-5

Setpoint wheel, white, unprinted (25 pieces) WMSPS-6

Page 198: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-21

Pressure switches

2

3

4

5

6

7

8

10

9

11

12

13

14

Pressure switches

For overpressure monitoring of non-aggressive liquids and gaseous media.

Fixed pressure hysteresis

Pressure switch for liquid, gas (DCM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65• -217: two microswitches, 1 plug, switching in succession,

adjustable switching interval• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Pressureadjustment range

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Sensing elementmaterial

Type

bar bar bar bar

0,04 ... 0,25 – 0,03 6 Copper + Brass DCM0250,1 ... 0,6 – 0,04 6 Copper + Brass DCM060,2 ... 1,6 – 0,04 6 Copper + Brass DCM10,2 ... 2,5 – 0,1 16 1.4104 + 1.4571 DCM3

0,5 ... 6 – 0,15 16 1.4104 + 1.4571 DCM60,5 ... 6 – 0,25 25 1.4104 + 1.4571 DCM6251 ... 10 – 0,3 25 1.4104 + 1.4571 DCM103 ... 16 – 0,5 25 1.4104 + 1.4571 DCM164 ... 25 – 1 60 1.4104 + 1.4571 DCM258 ... 40 – 1,3 60 1.4104 + 1.4571 DCM40

16 ... 63 – 2 130 1.4104 + 1.4571 DCM630,04 ... 0,25 – 0,03 6 1.4104 + 1.4571 DNM025

Page 199: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-22

Pressure switches

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Adjustable pressure hysteresis

For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.

Pressureadjustment range

Adjustable switchingdifferential

Switchingdifferential

Max.pressure

Sensing elementmaterial

Type

bar bar bar bar

0,04 ... 0,25 0,03 ... 0,4 – 6 Copper + Brass DCMV0250,1 ... 0,6 0,04 ... 0,5 – 6 Copper + Brass DCMV060,2 ... 1,6 0,07 ... 0,55 – 6 Copper + Brass DCMV10,2 ... 2,5 0,15 ... 1,5 – 16 1.4104 + 1.4571 DCMV3

0,5 ... 6 0,25 ... 2 – 16 1.4104 + 1.4571 DCMV61 ... 10 0,5 ... 2,8 – 25 1.4104 + 1.4571 DCMV103 ... 16 0,7 ... 3,5 – 25 1.4104 + 1.4571 DCMV164 ... 25 1,3 ... 6 – 60 1.4104 + 1.4571 DCMV258 ... 40 2,6 ... 6,6 – 60 1.4104 + 1.4571 DCMV40

16 ... 63 3 ... 10 – 130 1.4104 + 1.4571 DCMV63

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Differential pressure switch for liquid, gas (DDCM)

Kind of pressure differential pressure, relative

Pressure connection internal thread G1/4

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -205: maximum limiter with reclosing lock-out, interlocking with

increasing pressure• -206: Minimum limiter with reclosing lock-out, interlocking with

falling pressure• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)

• -217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Page 200: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-23

Pressure switches

2

3

4

5

6

7

8

10

9

11

12

13

14

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.

Accessories

Pressure adjustment range Switching differential Max. pressure Sensing element material Typebar bar bar

0,004 ... 0,025 0,002 0,5 Perbunan + Aluminium DDCM2520,01 ... 0,06 0,015 1,5 Perbunan + Aluminium DDCM6620,02 ... 0,16 0,02 3 Perbunan + Aluminium DDCM1602

0,1 ... 0,6 0,035 3 Perbunan + Aluminium DDCM6002-0,1 ... 0,4 0,15 15 1.4305 + 1.4571 DDCM0140,2 ... 1,6 0,13 15 1.4305 + 1.4571 DDCM1

1 ... 4 0,2 25 1.4305 + 1.4571 DDCM40,5 ... 6 0,2 15 1.4305 + 1.4571 DDCM63 ... 16 0,6 25 1.4305 + 1.4571 DDCM16

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Differential pressure switch for air (DPS)

Kind of pressure overpressure, relative

Pressure connection plastic connection piece for 5 mm (internal) hose

Electrical connection AMP connector 6,3x0,8 (DIN 46244) or screw terminals

Protection class IP54

Sensing element material ABS + Silicon

Media temp. -20 ... 85 oC

Ambient temperature -20 ... 85 oC

Switch function/capacity SPDT switch 240 Vac; 1,5 A (0.4)A

Certificates CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854

Max. pressure 10 kPa

Additional description Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.

Pressure adjustment range Switching differential TypePa mbar

20 ... 200 0,1 DPS20040 ... 400 0,2 DPS40050 ... 500 0,2 DPS500

200 ... 1000 1 DPS1000500 ... 2500 1,5 DPS2500

L-shaped bracket for installation turned by 90o, e.g. in the ceiling area DPSL

Page 201: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-24

Pressure switches

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.

Pressure monitor for hot water, steam, gas, fuel (DWR)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Mechanical lock/reset with special function possible

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -513: Gold-plated contacts, single-pole switch-over. Switching

differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier, degree of protection Ex-ia

• -574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP66, degree of protection Ex-ia

• -576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• CE-0085CL0343 according to DIN EN 1854, Issue 07.2006• 01 202 931-B-11-0003 according Directive 97/23 EC• SIL2 according IEC 61508-2

Page 202: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-25

Pressure switches

2

3

4

5

6

7

8

10

9

11

12

13

14

Fixed pressure hysteresis

Adjustable pressure hysteresis

Pressureadjustment range

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Allowable max.gas-pressure

Type

bar bar bar bar bar

0,1 ... 0,6 – 0,04 6 6 DWR060,2 ... 1,6 – 0,06 6 6 DWR10,2 ... 2,5 – 0,1 16 10 DWR3

0,5 ... 6 – 0,2 16 10 DWR60,5 ... 6 – 0,25 25 20 DWR6253 ... 16 – 0,5 25 20 DWR164 ... 25 – 1 63 50 DWR258 ... 40 – 1,3 63 50 DWR40

Pressureadjustment range

Adjustable switchingdifferential

Switchingdifferential

Max.pressure

Allowable max.gas-pressure

Type

bar bar bar bar bar

0,1 ... 0,6 0,08 ... 0,5 – 6 6 DWR06-2030,2 ... 1,6 0,15 ... 0,6 – 6 6 DWR1-2030,2 ... 2,5 0,17 ... 1,2 – 16 10 DWR3-203

0,5 ... 6 0,3 ... 1,4 – 16 10 DWR6-2030,5 ... 6 0,4 ... 2,5 – 25 20 DWR625-2033 ... 16 0,75 ... 3,15 – 25 20 DWR16-2034 ... 25 1,3 ... 6 – 63 50 DWR25-2038 ... 40 2,3 ... 6,6 – 63 50 DWR40-203

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 203: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-26

Pressure switches

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.

Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83

• CE-0085CL0343 according DIN EN 1854, Issue 7.2006• 01 202 931-B-11-0003 according to Directive 97/23 EG• SIL2 according IEC 61508-2

Pressure interlock/Reset minimum press./button

Pressure adjustment range Max. pressure Allowable max. gas-pressure Typebar bar bar

0,1 ... 0,6 6 6 DWR06-2060,2 ... 1,6 6 6 DWR1-2060,2 ... 2,5 16 10 DWR3-206

0,5 ... 6 16 10 DWR6-2060,5 ... 6 25 20 DWR625-2063 ... 16 25 20 DWR16-2064 ... 25 63 50 DWR25-2068 ... 40 63 50 DWR40-206

Syphon for high temperature, steel, U-shape, for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 204: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-27

Pressure switches

2

3

4

5

6

7

8

10

9

11

12

13

14

Maximum pressure limiter with selfmonitoring sensor and internal relockFor steam and hot water.

Maximum pressure limiter of 'special construction' (SDB)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Sensing element material 1.4104 + 1.4571

Media temp. -20 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -20 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Certificates • TUEV-SDB-11-134 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007

• 01 202 931-B-11-0001 according to Directive 97/23/EC• SIL2 according IEC 61508

Pressure interlock/Reset maximum press./button

Pressure adjustment range Switching differential Max. pressure Typebar bar bar

0,2 ... 1,6 0,12 5 SDBAM10,4 ... 2,5 0,15 5 SDBAM2.5

1,2 ... 6 0,4 10 SDBAM61,2 ... 6 0,6 20 SDBAM6253 ... 16 0,8 20 SDBAM166 ... 32 3 45 SDBAM32

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 205: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-28

Pressure switches

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.Features:

• Open-collector• Configurable as min./max./window monitor• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o

• Self-monitoring electronics• Adjustable drop-in/drop-out delay

Pressure Swith HMI

Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Media temp. -20 ... 80 oC

Protection class IP65

Ambient temperature -20 ... 70 oC

Pressure range Max. pressure Typebar bar

0 ... 0,1 0,9 PSHDM10020 ... 0,3 0,9 PSHDM3002

0 ... 1 3 PSHDB00120 ... 3 9 PSHDB00320 ... 6 21 PSHDB0062

0 ... 20 60 PSHDB0202

Page 206: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-29

Pressure sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

Pressure sensors

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.Models available with the following output types:

• all models: switch output open collector; 14..36 Vdc, 250 mA• PST -series: transmitter output; 0..10 Vdc or 4..20 mA• PST..R -series: relay output with gold plated SPDT contact

Switch + Transmitter, PST ...-models

Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Protection class IP65

Housing material Polybutylene terephtalate (PBT)

Sensing element material 1.4571 + 1.4435

Media temp. -20 ... 100 oC

Media temp. limit Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)

Ambient temperature -20 ... 60 oC

Switch function/capacity PST-models: Open collector switch max. 250 mA dc at 14 ... 36 Vdc. PST..R-models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.

Additional description • Applicable parameter settings:• switching Set / Reset points• filters• analog output range• electrical drag indicator• Applicable configurations:• Max-Min, Window monitor• Analog output signal• Pressure unit• Simulation mode• Plugs have to be ordered separately !

Pressure range (bar) Max. pressure (bar) Kind of pressure Type-1 ... 1 6 vacuum, relative PSTV01RG34F

0 ... 0,25 1 overpressure, relative PSTM250RG34F0 ... 0,4 2 overpressure, relative PSTM400RG34F0 ... 0,6 2 overpressure, relative PSTM600RG34F

0 ... 1 6 overpressure, relative PST001RG34F0 ... 1,6 6 overpressure, relative PST002RG34F

0 ... 4 12 overpressure, relative PST004RG34F0 ... 10 30 overpressure, relative PST010RG34F0 ... 25 75 overpressure, relative PST025RG34F0 ... 2 6 absolute PST002AG34F

0 ... 10 30 absolute PST010AG34F

Page 207: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-30

Pressure sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Switch + Transmitter + Relay output, PST..R -models

Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons

Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.Models available with the following output types:

• all models: switch output open collector; 14..36 Vdc, 250 mA• PST -series: transmitter output; 0..10 Vdc or 4..20 mA• PST..R -series: relay output with gold plated SPDT contact

Pressure range (bar) Max. pressure (bar) Kind of pressure Type-1 ... 1 6 vacuum, relative PSTV01RG34F-R

0 ... 0,25 1 overpressure, relative PSTM250RG34F-R0 ... 0,4 2 overpressure, relative PSTM400RG34F-R0 ... 0,6 2 overpressure, relative PSTM600RG34F-R

0 ... 1 6 overpressure, relative PST001RG34F-R0 ... 1,6 6 overpressure, relative PST002RG34F-R

0 ... 4 12 overpressure, relative PST004RG34F-R0 ... 10 30 overpressure, relative PST010RG34F-R0 ... 25 75 overpressure, relative PST025RG34F-R0 ... 2 6 absolute PST002AG34F-R

0 ... 10 30 absolute PST010AG34F-R

5-prong M12 plug connector, angled version ST12-5-A

5-prong M12 plug connector, straight version ST12-5-G

4-prong M12 plug connector, angled version ST12-4-A

4-prong M12 plug connector, straight version ST12-4-G

4-prong M12 plug connector, straight version with 2 m cable ST12-4-GK

4-prong M12 plug connector, angled version with 2 m cable ST12-4-AK

Plug protection cap, IP65 STA12

Syphons for high temperature, steel, U-shape. For more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Protection class IP65

Housing material Polybutylene terephtalate (PBT)

Media temp. -20 ... 100 oC

Media temp. limit Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)

Ambient temperature -20 ... 60 oC

Switch function/capacity PST..R-models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.

Sensing element material 1.4571 + 1.4542

Additional description Applicable parameter settings:• switching Set / Reset points• filters• analog output range• electrical drag indicator• Applicable configurations:• Max-Min, Window monitor• Analog output-signal• Pressure unit• Simulation mode• Plugs have to be ordered separately !

Page 208: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-31

Pressure sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

Switch + Transmitter output, PST-models

Switch + Transmitter + Relay output, PST..R -models

Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons

Pressure range Max. pressure Output signal Kind of pressure Typebar bar

-1 ... 1 6 0..10Vdc / 4..20 mA + switch vacuum, relative PSTV01RG12S0 ... 0,25 1 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM250RG12S

0 ... 0,4 2 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM400RG12S0 ... 0,6 2 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM600RG12S

0 ... 1 6 0..10Vdc / 4..20 mA + switch overpressure, relative PST001RG12S0 ... 1,6 6 0..10Vdc / 4..20 mA + switch overpressure, relative PST002RG12S

0 ... 4 12 0..10Vdc / 4..20 mA + switch overpressure, relative PST004RG12S0 ... 10 30 0..10Vdc / 4..20 mA + switch overpressure, relative PST010RG12S0 ... 25 75 0..10Vdc / 4..20 mA + switch overpressure, relative PST025RG12S0 ... 60 180 0..10Vdc / 4..20 mA + switch overpressure, relative PST060RG12S

0 ... 100 300 0..10Vdc / 4..20 mA + switch overpressure, relative PST100RG12S0 ... 250 500 0..10Vdc / 4..20 mA + switch overpressure, relative PST250RG12S0 ... 600 1000 0..10Vdc / 4..20 mA + switch overpressure, relative PST600RG12S

0 ... 2 6 0..10Vdc / 4..20 mA + switch absolute PST002AG12S0 ... 10 30 0..10Vdc / 4..20 mA + switch absolute PST010AG12S

Pressure range Max. pressure Output signal Kind of pressure Typebar bar

-1 ... 1 6 0..10Vdc / 4..20 mA + switch + relay vacuum, relative PSTV01RG12S-R0 ... 0,25 1 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM250RG12S-R

0 ... 0,4 2 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM400RG12S-R0 ... 0,6 2 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM600RG12S-R

0 ... 1 6 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST001RG12S-R0 ... 1,6 6 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST002RG12S-R

0 ... 4 12 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST004RG12S-R0 ... 10 30 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST010RG12S-R0 ... 25 75 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST025RG12S-R0 ... 60 180 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST060RG12S-R

0 ... 100 300 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST100RG12S-R0 ... 250 500 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST250RG12S-R0 ... 600 1000 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST600RG12S-R

0 ... 2 6 0..10Vdc / 4..20 mA + switch + relay absolute PST002AG12S-R0 ... 10 30 0..10Vdc / 4..20 mA + switch + relay absolute PST010AG12S-R

5-prong M12 plug connector, angled version ST12-5-A

5-prong M12 plug connector, straight version ST12-5-G

4-prong M12 plug connector, angle version ST12-4-A

4-prong M12 plug connector, straight version ST12-4-G

4-prong M12 plug connector, straight version with 2 m cable ST12-4-GK

4-prong M12 plug connector, angled version with 2 m cable ST12-4-AK

Plug protection cap, IP65 STA12

Syphons for high temperature, steel, U-shape. for more accessories, see Accessories for Pressure Switches / Transmitters

U430B

Page 209: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-32

Pressure sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.Features:

• Open-collector• Configurable as min./max/window monitor• Adjustable drop-in/drop-out delay• Hysteresis defined by set-point and reset-point• Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software

Pressure Switch HMI

Accessory

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.Features:

• Configurable as 0/2...10V or 0/4...20 mA (3-wire)• Adjustable attenuation filter• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software

Pressure Transmitter without HMI (2-wire, 4-20 mA)

Electronic Pressure switch for gas and liquid (Smart DCM)

Media temp. -20 ... 80 oC

Sensing element material 1.4571

Protection class IP65

Ambient temperature -20 ... 70 oC

Pressure range Max. pressure Typebar bar

-1 ... 1 6 PSHRV10110 ... 1 3 PSHRB00110 ... 4 12 PSHRB0041

0 ... 10 30 PSHRB01010 ... 16 48 PSHRB01610 ... 25 50 PSHRB02510 ... 40 80 PSHRB0401

Field configuration tool CFT1

Electronic Pressure transmitter for gas and liquid (Smart SN)

Media temp. -20 ... 80 oC

Sensing element material 1.4571

Certificates All 2-wire versions are SIL2 approved according IEC 61508

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

-1 ... 1 6 IP67 -20 ... 80 PTSRV1011A20 ... 1 3 IP67 -20 ... 80 PTSRB0011A20 ... 4 12 IP67 -20 ... 80 PTSRB0041A2

0 ... 10 30 IP67 -20 ... 80 PTSRB0101A20 ... 16 48 IP67 -20 ... 80 PTSRB0161A20 ... 25 50 IP67 -20 ... 80 PTSRB0251A20 ... 40 80 IP67 -20 ... 80 PTSRB0401A2

Page 210: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-33

Pressure sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

Pressure Transmitter without HMI (3-wire, 0-10V)

Pressure Transmitter without HMI (3-wire, 4...20mA)

Pressure Transmitter with HMI (2-wire, 4-20 mA)

Pressure Transmitter with HMI (3-wire, 0-10 V)

Accessory

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

-1 ... 1 6 IP67 -20 ... 80 PTSRV1011V30 ... 1 3 IP67 -20 ... 80 PTSRB0011V30 ... 4 12 IP67 -20 ... 80 PTSRB0041V3

0 ... 10 30 IP67 -20 ... 80 PTSRB0101V30 ... 16 48 IP67 -20 ... 80 PTSRB0161V30 ... 25 50 IP67 -20 ... 80 PTSRB0251V30 ... 40 80 IP67 -20 ... 80 PTSRB0401V3

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

-1 ... 1 6 IP67 -20 ... 80 PTSRV1011A30 ... 1 3 IP67 -20 ... 80 PTSRB0011A30 ... 4 12 IP67 -20 ... 80 PTSRB0041A3

0 ... 10 30 IP67 -20 ... 80 PTSRB0101A30 ... 16 48 IP67 -20 ... 80 PTSRB0161A30 ... 25 50 IP67 -20 ... 80 PTSRB0251A30 ... 40 80 IP67 -20 ... 80 PTSRB0401A3

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

-1 ... 1 6 IP65 -20 ... 70 PTHRV1011A20 ... 1 3 IP65 -20 ... 70 PTHRB0011A20 ... 4 12 IP65 -20 ... 70 PTHRB0041A2

0 ... 10 30 IP65 -20 ... 70 PTHRB0101A20 ... 16 48 IP65 -20 ... 70 PTHRB0161A20 ... 25 50 IP65 -20 ... 70 PTHRB0251A20 ... 40 80 IP65 -20 ... 70 PTHRB0401A2

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

-1 ... 1 6 IP65 -20 ... 70 PTHRV1011V30 ... 1 3 IP65 -20 ... 70 PTHRB0011V30 ... 4 12 IP65 -20 ... 70 PTHRB0041V3

0 ... 10 30 IP65 -20 ... 70 PTHRB0101V30 ... 16 48 IP65 -20 ... 70 PTHRB0161V30 ... 25 50 IP65 -20 ... 70 PTHRB0251V30 ... 40 80 IP65 -20 ... 70 PTHRB0401V3

Field configuration tool CFT1

Page 211: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-34

Pressure sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Double range differential pressure transmitter for air-conditioning/ventilation. For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc

Differential pressure transmitter for air (DPTM)

Kind of pressure differential pressure, relative

Pressure connection 6mm hose pipe

Electrical connection M20x1,5

Protection class IP54

Housing material ABS and POM

Sensing method piezoresistive

Sensing element material ABS + POM

Media temp. 0 ... 50 oC

Medium gaseous

Ambient temperature 0 ... 50 oC

Additional description Duct Kit DPSK included in delivery of single package.• Adjustable by jumper to the next higher pressure range.• Factory settings: see column "pressure range". Full scale pressure

range see data sheet

Pressure range (Pa) Max. pressure (kPa) Type-50 ... 50 20 DPTM50

-100 ... 100 20 DPTM110-500 ... 500 20 DPTM550

-1000 ... 1000 20 DPTM11000 ... 100/250 20 DPTM1000 ... 250/500 20 DPTM250

0 ... 500/1000 20 DPTM5000 ... 1000/2500 40 DPTM1000

0 ... 5000/10000 60 DPTM5000

Pressure range (Pa) Max. pressure (kPa) Type-50 ... 50 20 DPTM50D

-100 ... 100 20 DPTM110D-500 ... 500 20 DPTM550D

-1000 ... 1000 20 DPTM1100D0 ... 100/250 20 DPTM100D0 ... 250/500 20 DPTM250D

0 ... 500/1000 20 DPTM500D0 ... 1000/2500 40 DPTM1000D

0 ... 5000/10000 60 DPTM5000D

Pressure range (Pa) Max. pressure (kPa) Type-50 ... 50 20 DPTM52

-100 ... 100 20 DPTM112-500 ... 500 20 DPTM552

-1000 ... 1000 20 DPTM11020 ... 100/250 20 DPTM1020 ... 250/500 20 DPTM252

0 ... 500/1000 20 DPTM5020 ... 1000/2500 40 DPTM1002

0 ... 5000/10000 60 DPTM5002

Page 212: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-35

Pressure sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

Accessories

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.Features:

• Configurable as 0/2...10V or 0/4...20 mA (3-wire)• Adjustable attenuation filter• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o

• Self-monitoring electronics• Power supply 24 VAC/DC (3-wire models)• Power supply 18-35 V DC (2-wire models)

Pressure Transmitter with HMI (2-wire)

Pressure Transmitter without HMI (3-wire)

Pressure Transmitter with HMI (3-wire)

Duct Kit, including 2m silicone-hose and 2 joining pipes DPSJ with screws DPSK

Mounting brackets L-shaped DPSL

Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Media temp. -20 ... 80 oC

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

0 ... 0,1 0,9 IP65 -20 ... 70 PTHDM1002A20 ... 0,3 0,9 IP65 -20 ... 70 PTHDM3002A2

0 ... 1 3 IP65 -20 ... 70 PTHDB0012A20 ... 3 9 IP65 -20 ... 70 PTHDB0032A20 ... 6 21 IP65 -20 ... 70 PTHDB0062A2

0 ... 20 60 IP65 -20 ... 70 PTHDB0202A2

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

0 ... 0,1 0,9 IP67 -20 ... 80 PTSDM1002V30 ... 0,3 0,9 IP67 -20 ... 80 PTSDM3002V3

0 ... 1 3 IP67 -20 ... 80 PTSDB0012V30 ... 3 9 IP67 -20 ... 80 PTSDB0032V30 ... 6 21 IP67 -20 ... 80 PTSDB0062V3

0 ... 20 60 IP67 -20 ... 80 PTSDB0202V3

Pressure range Max. pressure Protection class Ambient temperature Typebar bar oC

0 ... 0,1 0,9 IP65 -20 ... 70 PTHDM1002V30 ... 0,3 0,9 IP65 -20 ... 70 PTHDM3002V3

0 ... 1 3 IP65 -20 ... 70 PTHDB0012V30 ... 3 9 IP65 -20 ... 70 PTHDB0032V30 ... 6 21 IP65 -20 ... 70 PTHDB0062V3

0 ... 20 60 IP65 -20 ... 70 PTHDB0202V3

Page 213: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-36

Air quality sensors

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Air quality sensors

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.

For sensing or controlling of CO2 concentration in buildings.

Air quality sensor

Protection class III as per EN60730-1I IP30 as per EN60529

Output signal 0..10Vdc

Power supply 24 Vacdc; 1 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Additional description Adjustable output offset and LED display

TypeC7110A1010

Room temperature/ CO2 sensor

LED functions operation as CO2 indicator

Output signal • CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm• temperature: 0..10 V

Power supply 24 Vac; 2 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Wiring terminals 3

Additional description Automatic baseline calibration, and quick calibration options.

TypeC7110C1001

Page 214: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-37

Air quality sensors

2

3

4

5

6

7

8

10

9

11

12

13

14

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.

Room temperature/ CO2 sensor

LED functions operation as occupancy indicator

Output signal CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm

Temperature element NTC20k

Temperature range 10 ... 35 oC

Setpoint knob -5 ... 5 oC

Extra setp. knob 12 ... 30 oC

Occupancy switch auto/bypass

Power supply 24 Vac; 2 VA

Mounting place internal wall

Housing (HxWxD) 104 mm; 99 mm; 30 mm

Wiring terminals 7

Additional description • Temperature setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.

• Automatic baseline calibration, and quick calibration options.

TypeC7110D1009

PC interface cable (PC software on request from Honeywell) HDI10

Air duct CO2 and temperature transmitter

Protection class IP65 when probe mounted downwards, otherwise IP20

Output signal The following output signals are applicable:• 0..10 V for 0..2000 ppm CO2• 0..10 V for 0..50 oC

Power supply 24 Vac; max. 3 VA

Mounting place air duct

Wiring terminals 5

TypeAQS71-KAM-T

Page 215: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-38

Miscellaneous

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Miscellaneous

Sensor to register solar radiation. Including two sensing elements.

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.

Sensor

Evaluation Unit

Fluid flow monitor consisting of two parts: the sensor type SWF.. and the belonging evaluation unit type ASW...

Solar sensor

Protection class IP30

Mounting place wall outside

Housing (HxWxD) 120 mm; 60 mm; 50 mm

Wiring terminals 3

Additional description To be connected to a 10Vdc output from a controller as power supply. The solar output signal (0..5Vdc = 0..500 W/m2) must be connected to an analogue input of the controller.

TypeSAF25

Electronical air flow switch for air (ASL)

Protection class sensor: IP32

Output signal evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed

Additional description Media temperature at sensor: -20..100 oC.

Mounting place Immersion depth Power supply Typemm Vac; VA

air duct 150 –; – SLF15

Mounting place Immersion depth Power supply Typemm Vac; VA

universal – 24; 3 ASL453/24universal – 230; 3 ASL453

Electronical flow switch for liquid (ASW)

Protection class sensor: IP65; evaluation unit: IP32

Output signal evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed

Additional description For sensor:• media temperature 0..80 oC• sensing element steel

Page 216: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-39

Miscellaneous

2

3

4

5

6

7

8

10

9

11

12

13

14

Sensor

Evaluation unit

The flow switches are designed for monitoring flow rates in pipes and ducts employed in HVAC applications.For monitoring flow of non-aggressive gases in air ducts of air conditioning systems and air treatment systems.

The flow switches are designed for monitoring flow rates in pipes employed in HVAC applications.For monitoring flow in water, oil, cooling circuits, and lubrication systems.

Liquid

Power supply Mounting place Immersion depth Connection diameter TypeVac; VA mm inch

–; – in pipe 25 G1/4 SWF62–; – in pipe 45 G1/2 SWF62L

Power supply Mounting place Immersion depth Connection diameter TypeVac; VA mm inch

230; 3 universal – – ASW45424; 3 universal – – ASW454/24

Paddle flow switches for air (S6040)

Protection class IP65

Switch function/capacity SPDT, capacity 250Vac, (8)15 A

Setpoint device screw

Max. media temperature 85 oC

Setpoint range 2,5..9,2m/s

Max. pressure 0,25 bar

TypeS6040A1003

Paddle set PA1

Paddle flow switches for liquid (S6065)

Protection class IP65

Switch function/capacity SPDT, capacity 250Vac, (8)15 A

Setpoint device screw

Approvals TUEV-approval

Max. media temperature 120 oC

Setpoint range 0,6..165 m3/h pipe size dependent

Media Max. pressure Typebar

liquid non-aggressive 11 S6065A1003liquid aggressive 30 S6065A2001

Page 217: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

8-40

Miscellaneous

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.

Process connection G1/2"

This early-warning dew-point switch is designed for use in monitoring cooling water pipes or chilled surfaces in order to determine if temperatures are approaching the dewpoint. It is suitable for mounting on flat and round surfaces. The switch measures the relative humidity prevailing directly at the chilled surface and can thus be used to:

• regulating cooling performance• switching cooling systems ON and OFF• signalling if the temperature is approaching the dew-point

Status indication with LED, showing condensation dangerSwitching point at 90 %rh, hysteresis 5 %rh

Electronic flow switches for liquid, compact version (KSW)

Protection class IP65

Switch function/capacity SPDT, capacity 250 Vac, 10(2) A

Immersion depth 20 mm

Media liquid and air

Setpoint range 0,05..3 m/s

Max. media temperature 80 oC

Max. pressure 30 bar

Additional description LED's available for indication of power supply and switch status.

Power supply TypeVac; VA

24; 4 KSW24230; 4 KSW230

Dew-point switch

Ambient temperature 0 ... 50 oC

Protection class IP40

Mounting wall, duct or pipe (max. 50 mm)

Power supply 24 Vac; 0,3 VA

Switch function/capacity potential free changeover contact; max. 24 Vac/dc, 1 A

Wiring connection 5-pole push-in terminals, max. 1,5mm2

TypeHSS-DPS

Page 218: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Thermostats Page

Individual room control 9-2Fan coil electro-mechanical control 9-3Fan coil digital control 9-7Liquid/air temperature control 9-10Frost protection 9-12Safety thermostats 9-13Room thermostats 9-21

Page 219: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-2

Individual room control

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Individual room control

Digital controller for individual zone control of terminal units in fan coil and air conditioning systems, with great applications flexibility. The controller provides position control of valves or dampers (for airside control), and is capable of mounting on a switching sub-base for manual control of the fan speed.The controller can be configured (with dipswitches) for the following applications:

• Heat / Cool changeover• Cooling only• Cooling + optional 2 stages On/Off Heating• Heating only• Heating + optional 2 stages On/Off Cooling• Heating + Cooling Sequence Control

Accessories

Room temperature controller 24Vac, modulating, on/off, T8078C

Control output signal 2 triacs for 1 valve open/close; 2 triacs for 2nd valve open/close or 2 on/off stages; max. load 8 VA /triac (24 V)

Control functions dipswitch settings for:• PI Modulating (3-position)• PI On/Off• thermal actuator control using TPM (=Thermal Predictive

Modulating)• proportional band• zero energy band

Temperature element NTC100k

Temp. setpoint range 15 ... 30 oC

Optional inputs remote sensor, remote setpoint adjustment, heat/cool changeover, energy savings contact

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Protection class IP30

Power supply 24 Vac; 1,2 VA

Additional description • easy system check with LED and PC-output port• easy commissioning with automatic valve pulsing• periodic valve excercise and synchronisation• remote sensor auto-detect

TypeT8078C1009

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Wall-plate to allow mounting onto different wall boxes (5 pieces) F42007789 001

Remote setpoint module (-5..+5 K) Q979B1029

Remote sensor and setpoint module (-5..+5 K) Q979C1036

Wall mounted space temperature sensor Q979A1020

Remote sensor for duct or terminal unit mounting (1.5m cable) T8109C1002

External pipe thermostat for automatic heat/cool changeover S4390A1004

Fan speed switching subbase (230 V) Q6360A1025

Page 220: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-3

Fan coil electro-mechanical control

2

3

4

5

6

7

8

10

9

11

12

13

14

Fan coil electro-mechanical control

Wall mounted line voltage fan-coil thermostat.For control of fan only in fan coil and ventilation applications.

Accessories

XE-70 thermostat, 230Vac, 2-pipe fan-coil, fan only control, T6370/T6371

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230Vac, 4 A resistive, 2 A inductive ratings

Terminal max. wire size 1,5 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator yes

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 130 mm; 85 mm; 40 mm

Additional description T6371C uses a pipe thermostat (L641B1004) to provide automatic heat/cool changeover, depending on the temperature of the water supplied to the fan-coil unit.

Heating /Coolingapplication

Manual operationfunctions

Fanswitch

Heat/Cool manualmode

Automatic Heat/Coolchange over

Type

H or C – – – – T6370A1010H or C on/off switch 1/2/3 – – T6371A1019H + C on/off switch 1/2/3 H/C – T6371B1017H + C on/off switch 1/2/3 – ext. thermostat T6371C1015

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Pipe thermostat to allow automatic heat/cool changeover with T6371C L641B1004

Page 221: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-4

Fan coil electro-mechanical control

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wall mounted line voltage fan-coil thermostat.For control of the valve, or the valve and the fan in 2-pipe fan-coil applications.

Accessories

XE-70 thermostat, 230Vac, 2-pipe fan-coil, fan & valve control, T6372/T6373

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230Vac, 4 A resistive, 2 A inductive ratings

Terminal max. wire size 1,5 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator yes

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 130 mm; 85 mm; 40 mm

Additional description T6372C and T6373C use a pipe thermostat (L641B1004) to provide automatic heat/cool changeover, depending on the temperature of the water supplied to the fan-coil unit. T6373A1157 requires a central switch to change from heating to cooling, for central control of multiple units.

Heating /Coolingapplication

Manual operationfunctions

Fan switch Fan cycledor continuous

Heat/Coolmanual mode

Automatic Heat/Cool change over

Type

H or C on/off switch – both – – T6372A1018H + C – – both H/C – T6372B1024H + C on/off switch – both H/C – T6372B1032H + C on/off switch – both – ext. thermostat T6372C1014H or C on/off switch 1/2/3 continuous – – T6373A1017H or C on/off switch 1/2/3 continuous – – T6373A1157H + C on/off switch 1/2/3 continuous H/C – T6373B1015H + C on/off switch 1/2/3 both H/C – T6373B1064H + C on/off switch 1/2/3 continuous – ext. thermostat T6373C1013

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Pipe thermostat to allow automatic heat/cool changeover with T6371C L641B1004

Page 222: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-5

Fan coil electro-mechanical control

2

3

4

5

6

7

8

10

9

11

12

13

14

Wall mounted line voltage fan-coil thermostat.For control of the valves, or the valves and the fan in 4-pipe fan-coil applications, with the possibility of also being used for the control of split units or small air-conditioners.

Accessories

XE-70 thermostat, 230Vac, 4-pipe fan-coil, fan & valve control, T6374/T6375

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230Vac, 4 A resistive, 2 A inductive ratings

Terminal max. wire size 1,5 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator yes

Heating /Cooling application

H + C

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 130 mm; 85 mm; 40 mm

Additional description T6374C and T6375C have sequence control with a deadband of 1.5 oC between heating and cooling operating points.

Manual operationfunctions

Fan switch Fan cycledor continuous

Heat/Coolmanual mode

Automatic Heat/Coolchange over

Type

– – – – seq. control T6374C1004on/off switch – continuous – seq. control T6374C1012on/off switch 1/2/3 continuous H/fan/C – T6375B1013on/off switch 1/2/3 continuous H/C – T6375B1021on/off switch 1/2/3 continuous – seq. control T6375C1003on/off switch 1/2/3 both H/C – T6375D1001

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Page 223: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-6

Fan coil electro-mechanical control

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wall mounted line voltage HVAC thermostat.For control of the fan, compressor, reversing valve, and auxiliary heater in split units, heatpumps, and small air conditioners.

Accessories

XE-70 thermostat, 230Vac, heatpump & air-conditioner control, T6376/T6377

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230Vac, 4 A resistive, 2 A inductive ratings

Terminal max. wire size 1,5 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heating /Cooling application

H + C

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 130 mm; 85 mm; 40 mm

Additional description T6376B, T6377B1003, T6377B1011 are suitable for heatpumps with reversing valve. T6376B, T6377B1045, T6377B1151 are suitable for air-conditioners.

Heatanticipator

Temperaturecontrolled output

Additionaloutput

Manualoperationfunctions

Fan switch Fan cycled orcontinuous

Heat/Coolmanual mode

Type

• fan + compressor+ heater

rev. valve – auto/cont. both H/off/C T6376B1004

• compressor rev. valve on/off switch 1/2/3 continuous H/fan/C T6377B1003– fan + compressor rev. valve – 1/2/3+auto/cont. both H/off/C T6377B1011• fan + compressor

+ heater– – 1/2/3+auto/cont. both H/off/C T6377B1045

– fan + valve +heater

– on/off switch 1/2/3 both H/em.heat/C T6377B1151

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Page 224: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-7

Fan coil digital control

2

3

4

5

6

7

8

10

9

11

12

13

14

Fan coil digital control

Fan-coil controller with large LCD display, and built in room sensorFor on/off P+I control of valves and fan. Selectable applications:

• 2 pipe system, heating only• 2 pipe system, cooling only• 2 pipe system, heating or cooling, manual change-over

Two-pipe fan coil controller with LCD display T6812

Fan coil controller with LCD display for 2-pipe systems, T6812

Temp. setpoint range 10 ... 32 oC

Control output signal switches (230V 2A inrush 3,5A) on/off for heating- and cooling valve, switches (230V 4A inrush 10A)for fan (3-speed)

Manual operation functions

on/off; room setpoint; fan speed low/med/high; heat/cool change-over

Display functions setpoint temperature, room temperature, mode of operation: heat, cool or fan only

Housing (HxWxD) 126 mm; 86 mm; 29 mm

Protection class IP30

Mounting directly on wall or wall-box

Terminal max. wire size 2,5 mm2

Product literature language

controller supplied with installation instructions in English, French, Dutch, Spanish

Power supply 230V 50Hz

Additional description • Installer Set Up table for application selection and parameter settings

• parameter settings and setpoint retained in event of power loss• installer test mode for on-site wiring checks• LCD display with backlight• keypad lockout

TypeT6812A1000

Page 225: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-8

Fan coil digital control

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Fan-coil controller with built in room sensorFor on/off P+I control of valves, fan and auxiliary electric heater. Models available for 2 or 2/4 pipe systems.

• heating/cooling sequence with auxiliary electric heater (water sensor required)• electric heater / cooling sequence• ventilation only• auto changeover (water sensor or external contact required)• freeze protection (if window contact activated)

Sensors

Fan coil controller TIREE, T6580

Temp. setpoint range 10 ... 30 oC

Input signal optional return air room sensor, water sensor, setback contact for energy saving, window contact and changeover contact

Control output signal triacs (230V 0,8A) on/off or PWM for heating- and cooling valve, switches (230V 1,25A inrush 3A) for fan (3-speed) and heater

Power supply 230 Vac; 5 VA

Manual operation functions

room setpoint; fan speed auto/off/low/med/high

Housing (HxWxD) 88 mm; 118 mm; 31 mm

Protection class IP30

Mounting directly on wall, wall box or fan-coil chassis

Terminal max. wire size 2,5 mm2

Product literature language

controller supplied with installation instructions in English, French, Italian, Spanish

Product description TypeFan Coil controller for 2/4 pipe systems. With push buttons for changeover, comfort/economy and indication LED; adjustable dead band for heat/cool sequence operation; Installer Set Up routine for parameter settings

T6580A1008

Fan Coil controller Lite. For 2-pipe systems. Only on/off outputs. T6580A1016

Return air room temperature sensor NTC10k RFCA-SR10

Page 226: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-9

Fan coil digital control

2

3

4

5

6

7

8

10

9

11

12

13

14

Fan-coil controller with large LCD display, and built in room sensorFor on/off P+I control of valves, fan and auxiliary electric heater. Eight applications selectable:

• 2 pipe system, heating only• 2 pipe system, cooling only• 2 pipe system, heating or cooling• 2 pipe system, heating or cooling, auto changeover (water sensor required)• 2 pipe system, heating or cooling with auxiliary electric heater (water sensor required)• 4 pipe system, heating or cooling• 4 pipe system, heating or cooling, auto changeover• 4 pipe system, mixed manual and auto

Sensors

Fan coil controller with LCD display, T6590

Temp. setpoint range 10 ... 32 oC

Input signal optional remote room sensor, water sensor, setback contact for energy saving

Control output signal switches (230V 1A inrush 3A) on/off for heating- and cooling valve, switches (230V 3A inrush 6A)for fan (3-speed) and heater

Power supply 230 Vac; 5 VA

Manual operation functions

room setpoint; fan speed on/off, low/med/high or auto; heat/cool change-over manual or auto

Display functions setpoint temperature, room temperature, mode of operation: heat, cool or standby

Housing (HxWxD) 97 mm; 148 mm; 29 mm

Protection class IP30

Mounting directly on wall or wall-box

Terminal max. wire size 2,5 mm2

Product literature language

controller supplied with installation instructions in English, French, Italian, Spanish

Additional description • Installer Set Up routine for application selection and parameter settings

• parameter settings retained in event of power loss• adjustable dead band for heat/cool sequence operation• activity sensing: back to energy saving mode if no button is

pressed for a selected period of time• freeze protection• LCD display with bright backlight• keypad lockout (total or partial)

Product description TypeFan Coil controller, for 2-pipe systems only T6590A1000Fan Coil controller, for 2-pipe or 4-pipe systems T6590B1000

Room temperature sensor NTC20k RF20

Strap-on water temperature sensor NTC20k T7414C1012

Pipe thermostat to allow automatic heat/cool changeover L641B1004

Page 227: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-10

Liquid/air temperature control

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Liquid/air temperature control

Thermostat for limiting and controlling boiler water temperature in hydronic heating systems.

Knob setting

Internal setting

Internal setting, manual reset

Single Aquastat direct immersion SPDT, L6188

Electrical rating • 10A at 250Vac, resistive load• 2,5A at 250Vac, inductive load• 15A at 250Vac, locked rotor• 2A at 24Vac, inductive load

Ambient temperature 0..70 oC

Terminals 6.3 mm quick connect, suitable for 1/4" receptacle

Switch SPDT

Mounting direct immersion

Cover and Conduit box yes

Kind of terminals quick connect + screw

Temperaturerange

Differentialtemp.

Capillarylength

Mountingbracket

Limit stop Well Index onknob

Push inplug

Type

mm

25..95 oC 4..10 oC 22 – – • • – L6188A200240..110 oC 4..10 oC 22 – – • • – L6188A201070..140 oC 4..10 oC 22 – – • • – L6188A203640..110 oC 4..10 oC 22 – low + high – • • L6188A2044

25..95 oC 4..10 oC 22 – – • • – L6188A208525..95 oC 4..10 oC 1500 • – – • – L6188A2093

Temperaturerange

Differentialtemp.

Capillarylength

Mountingbracket

Limit stop Well Index onknob

Push inplug

Type

mm

70..140 oC 4..10 oC 1500 • – – – • L6188B201840..110 oC 4..10 oC 22 – – – – – L6188B2026

25..95 oC 4..10 oC 22 – – • – • L6188B203425..95 oC 4 oC 100 – – – – – L6188B204225..95 oC 4 oC 1000 • – – – • L6188B2059

Temperaturerange

Differentialtemp.

Capillarylength

Mountingbracket

Limit stop Well Index onknob

Push inplug

Type

mm

70..140 oC manual reset 1500 • – – – • L6188C200825..95 oC manual reset 22 – – • – • L6188C2016

Page 228: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-11

Liquid/air temperature control

2

3

4

5

6

7

8

10

9

11

12

13

14

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes.

Immersion wells

Immersion tubes NPT

More Accessories

Capillary tube thermostat with sensing bulb (TAM)

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material die-cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 70 oC

Switch function/capacity SPDT 250 Vac, 8(5) A

Capillary tube length 1,5 m

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -351: protection class IP65 and switching housing with surface

protection (chemical version)• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Thermostat application capillary tube thermostat

Temp. setpoint range Differential fixed Max. perm. temp. at sensor TypeoC K oC

-20 ... 20 1,5 110 TAM02210 ... 50 1,5 110 TAM15040 ... 90 2 125 TAM490

80 ... 130 2 150 TAM813

Red brass well G1/2" PN25, immersion/total length 135/151 mm R1/MS

Stainless steel well G1/2" PN63, immersion/total length 135/151 mm R1/Nst

Red brass well G1/2" PN25, immersion/total length 220/236 mm R2/MS

Stainless steel well G1/2" PN63, immersion/total length 220/236 mm R2/Nst

Red brass well G1/2" PN25, immersion/total length 500/516 mm R3/MS

Capillary tube bushing with 3 mm capillary tube screw in thread G1/2, not pressure-tight

R4

Capillary tube bushing, rubber plug for 3 mm capillary tube, bore diameter 10 mm, not pressure-tight

R5

Red brass well G1/2" NPT PN25, immersion/total length 135/151 mm RN1/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 135/151 mm RN1/NST

Red brass well G1/2" NPT PN25, immersion/total length 220/236 mm RN2/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 220/236 mm RN2/NST

Sealing P2

Heat conducting compound WLP1

Page 229: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-12

Frost protection

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Frost protection

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.

Single-stage frost protection thermostat (FT69)

Housing material Polycarbonate and ABS

Ambient temperature -20 ... 55 oC

Switch function/capacity SPDT 24..250 Vac, 15(8)A

Thermostat application frost protection thermostat

Protection class IP65

Capillary tube length Mechanical lock/reset Typem

1,8 manual FT6960-18F3 manual FT6960-30F6 manual FT6960-60F

1,8 automatic FT6961-18F3 automatic FT6961-30F6 automatic FT6961-60F

Capillary tube length Mechanical lock/reset Typem

1,8 manual FT6960-183 manual FT6960-306 manual FT6960-60

1,8 automatic FT6961-183 automatic FT6961-306 automatic FT6961-60

Page 230: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-13

Safety thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Safety thermostats

Sealing pipe thermostat with well.

Accessories

Safety limiting thermostat, with hand reset (STB1)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity SPST 230 Vac, 10 A

Mechanical lock/reset mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval STB 89 507

Thermostat application immersion tube thermostat

Thermostat functions temp. setting inside, reset outside

Temp. setpoint range 60 ... 130 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

150 oC

TypeSTB1

Steel well R1/2" x 150 mm T4NST

Steel well R1/2" x 150 mm T4NSTF

Page 231: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-14

Safety thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The STB Servies of universal strap-on thermostats are designed for floor heating applications. They are suitable for use as strap-on, wall-mounted, or (with optional immersion well) immersion thermostat.Devices of the STB Series likewise measure temperature. If the sensor temperature exceeds the set value, a snap-action switch opens, interrupting the electrical circuit, and remains open until reset manually. (Also, if the sensor temperatuire drops to below approx. - 20 degrees C, the snap-action switch opens, but closes again automatically after the temperature rises again.) To manually reset the device, the sensor temperature must drop by more than approx. 10 K.

Accessories

Safety strap-on thermostat (temperature limiter) for floor heating applications (STB)

Electrical connection M20x1,5

Protection class IP54

Housing material PA, ABS, PMMA

Ambient temperature 0 ... 80 oC

Switch function/capacity max: 230Vac, 12 (2,5) A / min: 24 Vac/dc, 100 mA

Mechanical lock/reset manual reset

Setpoint device knob

Certificates CE, UL, PED, DIN EN 14597

Thermostat application strap-on thermostat

Differential fixed 10 K

Temp. setpoint range TypeoC

20 ... 80 STB208070 ... 130 STB70130

Temp. setpoint range TypeoC

20 ... 80 STB2080F70 ... 130 STB70130F

Immersion Well, G1/2 STG12-100

Page 232: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-15

Safety thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Sealing pipe thermostat with well.

Accessories

Safety limiting thermostat, hand reset, large range (STW1)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity SPDT 230 Vac, 10 A

Mechanical lock/reset no mechanical lock

Certificates TUEV-approval STW (STB)89 407 S

Thermostat application immersion tube thermostat

Thermostat functions temp. setting inside, reset inside

Temp. setpoint range 20 ... 150 oC

Mounting place in pipe

Immersion depth 150 mm

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

175 oC

Additional description Fixed switching differential approx. 4% of setpoint value.

TypeSTW1

Steel well R1/2" x 150 mm T4NST

Steel well R1/2" x 150 mm T4NSTF

Page 233: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-16

Safety thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The STW Servies of universal strap-on thermostats are designed for floor heating applications. They are suitable for use as strap-on, wall-mounted, or (with optional immersion well) immersion thermostat.Devices of the STW Series measure temperature. If the sensor temperature exceeds the set value, a snap-action switch opens, interrupting the electrical circuit. As soon as the sensor temperature drops by more than 10 K, the snap-action switch again closes automatically. (Also, if the sensor temperature drops to below approx. 20 degrees C, the snap-action switch opens, but closes again automatically after the temperature rises again.

Accessories

Accessories

Safety strap-on thermostat for floor heating applications (STW)

Electrical connection M20x1,5

Protection class IP54

Housing material PA, ABS, PMMA

Ambient temperature 0 ... 80 oC

Switch function/capacity max: 230Vac, 12 (2,5) A min: 24 Vad/dc, 100 mA

Mechanical lock/reset automatic reset

Setpoint device knob

Certificates CE, UL, PED, DIN EN 14597

Thermostat application strap-on thermostat

Differential fixed 10 K

Temp. setpoint range TypeoC

20 ... 80 STW208070 ... 130 STW70130

Temp. setpoint range TypeoC

20 ... 80 STW2080F70 ... 130 STW70130F

Immerson well, G1/2, 100 mm STG12-100

Immerson well, G1/2, 100 mm STG12-100F

Page 234: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-17

Safety thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Safety limiting thermostat with setpoint knob, shut-off (STBTR)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval TR / STB 90 007

Thermostat application immersion tube therm. + controller

Thermostat functions temp. setting inside + outside, reset outside

Temp. setpoint range 30 ... 110 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

130 oC

Additional description Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.

TypeSTB+TR

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 235: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-18

Safety thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Safety limiting thermostat with setpoint knob, shut-off, automatic reset (STWTR)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, automatic reset

Immersion depth 150 mm

Certificates TUEV-approval TR / STW (STB)89 907 S

Thermostat application immersion tube therm. + controller

Thermostat functions temp. setting inside + outside, reset inside

Temp. setpoint range 20 ... 150 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

175 oC

Additional description Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 20..150 oC adjustable.

TypeSTW+TR

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 236: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-19

Safety thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Safety limiting thermostat, with shut-off (STBTW)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval TW / STB 90 407

Thermostat application immersion tube therm. + monitor

Thermostat functions temp. setting inside, reset outside

Temp. setpoint range 30 ... 110 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

130 oC

Additional description Safety control switching differential approx. 3..4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.

TypeSTB+TW

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 237: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-20

Safety thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Sealing pipe thermostat with well.The temperature monitor can be used for heating systems according to DIN 4751 for steam and hot water systems and for district heating systems.

Accessories

Flue gas thermostat for safety control of solid fuel boilers (in combination with oil boilers).

Safety limiting thermostat, automatic reset (TWP1)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity SPDT 230 Vac, 10 A

Mechanical lock/reset no mechanical lock

Immersion depth 100 mm

Certificates TUEV-approval TW 89 207

Thermostat application immersion tube thermostat

Thermostat functions temp. setting inside, automatic reset

Temp. setpoint range 20 ... 150 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

175 oC

TypeTWP1

Steel well R1/2" x 150 mm T4NST

Flue gas thermostat

Switch function/capacity SPDT 10A/250Vac

Setpoint device inside

Mounting place flue gas vent

Temp. setpoint range 20 ... 400 oC

Differential setting range 10 ... 18 oC

TypeRGT240

Page 238: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-21

Room thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Room thermostats

Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.

Line voltage thermostat for control of heating-, cooling-, and ventilation systems in farm buildings, storage areas, swimming pools etc.

Room thermostat, industrial, 1/2 stages (T6120)

Housing material glass fibre reinforced ABS

Setpoint device knob

Thermostat application room thermostat

Differential fixed 1 K

Additional description T6120B is dual stage, with 2..10 K difference between the stages.

Temp. setpoint range Switch function/capacity Protection class TypeoC

0 ... 60 SPDT 250Vac 10A (1,5A) IP54 T6120A1005-30 ... 30 SPDT 250Vac 15A (8A) IP65 T6120B1003

Room thermostat, corrosion resistive

Switch function/capacity SPST enclosed Micro switch 230Vac , 5 A resistive, 3,7 A inductive

Differential fixed 1,7 oC

Temperature element capillary

Heating /Cooling application

H or C

Temp. setpoint range TypeoC

-10 ... 30 T631C117820 ... 60 T631C1160

Page 239: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

9-22

Room thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.

Fixed switching difference

Adjustable switching difference

Accessories

Room thermostat for industrial permises (TRM)

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material die cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 70 oC

Switch function/capacity SPDT 250 Vac, 8(5) A

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -351: protection class IP65 and switching housing with surface

protection (chemical version)• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc,

100 mA, min. 5 Vdc, 2 mA, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Thermostat application room thermostat, industrial

Additional description Including mounting bracket typenumber H1.

Temp. setpoint range Differential fixed Differential setting range Max. perm. temp. at sensor TypeoC K K oC

-20 ... 20 1 – 70 TRM0220 ... 40 1 – 70 TRM40

10 ... 50 1 – 70 TRM150

Temp. setpoint range Differential fixed Differential setting range Max. perm. temp. at sensor TypeoC K K oC

0 ... 40 – 3 ... 10 70 TRMV4010 ... 50 – 3 ... 10 70 TRMV150

Cover for outdoor application S1

Sealing P2

Heat conducting compound WLP1

Page 240: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Miscellaneous Page

Humidistats 10-2Switches 10-4Transformers 10-5

Page 241: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

10-2

Humidistats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Humidistats

Line voltage humidistats for (de)humidification 2-point control in air conditioning systems. Also applicable for swimming pools (dehumidification).

Room humidistat H6120

Duct humidistat H6045

Low voltage humidistat for humidity control of rooms.

Room and air duct humidistats (H)

R.H. setpoint range 35 ... 100 %rh

(De) Humidification application

D + H

Additional description Maximum air flow speed for ducts: 8 m/s.

R.H. hysteresisswitching point

Ambienttemperature

Mountingplace

Immersiondepth

Switchfunction/capacity

Protectionclass

Type

%rh oC mm

4 0 ... 60 internal wall – SPDT 230Vac /5A (0,2A) IP30 H6120A1000

R.H. hysteresisswitching point

Ambienttemperature

Mountingplace

Immersiondepth

Switchfunction/capacity

Protectionclass

Type

%rh oC mm

5 -10 ... 65 air duct 222 SPDT 250Vac/15A (8A) IP65 H6045A1002

Room humidistat, low voltage

Switch function/capacity SPDT 48 Vac, 6 A

R.H. hysteresis switching point

5 %rh

Ambient temperature 10 ... 50 oC

R.H. sensing element nylon

(De) Humidification application

D + H

Mounting place internal wall

Additional description With internal setpoint adjustment limiter. Including mounting base/ring.

R.H. setpoint range Type%rh

30 ... 80 H615A201550 ... 90 H615A2077

Page 242: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

10-3

Humidistats

2

3

4

5

6

7

8

10

9

11

12

13

14

Line voltage immersion humidistat for air ducts or industrial areas.

Air duct humidistat

Switch function/capacity SPDT 230 Vac, 15 A

R.H. setpoint range 35 ... 100 %rh

R.H. hysteresis switching point

4 %rh

Ambient temperature -30 ... 60 oC

R.H. sensing element plastic tissue

(De) Humidification application

D + H

Mounting place air duct

TypeHGK3

Page 243: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

10-4

Switches

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Switches

Wall mounted switching module.For manual control of the valve, or the valve and the fan in fan-coil applications.

Switching module, Q6371

Approvals CE

Protection class IP30

Switch function/capacity manual switch outputs, 230Vac, 6 A resistive, 4 A inductive ratings

Terminal max. wire size 1,5 mm2

Manual operation functions

on/off switch

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 83 mm; 84 mm; 27 mm

Heating /Cooling application Fan switch Heat/Cool manual mode TypeH or C 1/2/3 – Q6371A1006H + C yes H/C Q6371C1002H + C 1/2/3 H/C Q6371C1010

Page 244: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

10-5

Transformers

2

3

4

5

6

7

8

10

9

11

12

13

14

Transformers

Transformer to be mounted outside of cabinets, built in closed housing.

Transformer

Protection class IP00

Input voltage 220/230 V selectable, 50Hz

Output voltage 24Vac

Additional description With mains fuse. VDE0551 mark.

Model Type48 VA CRT2144 VA CRT6288 VA CRT12

Transformer, 2 secondary windings

Protection class IP00

Input voltage 230 V, 50Hz

Output voltage 2 x 24Vac, separated

Additional description With mains fuse. VDE0551 mark.

Model Type144/144 VA CRT6-6150/250 VA CRT6-12

Transformer wall mounting

Protection class IP54

Input voltage 220 V, 50/60Hz

Output voltage 24Vac

Additional description Power 45 VA• With mains cable 1,5 m and mains plug.• With low voltage cable 3 m, without plug.

TypeETR2

Page 245: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

10-6 http://products.ecc.emea.honeywell.com/europe

Page 246: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Thermostats, Timers Page

Chronotherms wireless 11-2Chronotherms wired 11-4Room thermostats 11-8Water thermostats 11-15Timers 11-16

Page 247: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-2

Chronotherms wireless

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Chronotherms wireless

The CM920 (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven CM60RFNG programming philosophy. To further improve the ease of use and assist installation this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.Used for general purpose control of boiler, zone values, circulation pumps, thermal actuators, electric heaters, heat pumps, etc. in heating and cooling systems.

7-day program

1-day program

RF Chronotherm with extended feature set and slim ultra-modern design CM927, CM921

Power source transmitter (room unit): battery powered, 2 x 1,5 V AA Alkaline cells supplied; receiver (relay box): mains powered 230 V, 50 Hz

Battery life 2 years typical

Switch function/capacity SPDT, 24..230 Vac, 10 A resistive, 3 A inductive

Protection class IP30 (receiver and transmitter)

RF frequency range 868 ... 868,6 MHz

Blocking immunity Receiver class 2 (ETSI EN300220-1 version 1.3.1)

Terminal max. wire size 2,5 mm2

Temp. setpoint range 0 ... 35 oC

Control functions Fuzzy Logic Algorithm

Temperature setpoints per day

6

Time setting resolution time of day 1 minute, program 10 minute steps

Heating /Cooling application

H or C

Manual operation functions

manual setpoint setting (MAN) and frost protection (OFF) modes available

Holiday mode yes

Optimisation yes

Additional description • LCD backlighting• automatic summer/winter time change• user program stored in non-volatile memory• factory pre-set RF link between the room unit and the relay box• installer set-up mode

Default timedisplay format

Partytimer

Day offfunction

Product literaturelanguage

Display Type

24 h • • NL, F Dutch/French CMT927A101524 h • • F French CMT927A102324 h • • E Spanish CMT927A1031

AM/PM • • UK English CMT927A104924 h • • I Italian CMT927A105624 h • • D, HU, PO German/Hungarian/Portugese CMT927A106424 h • • CZ, SK, PL Czech/Slovak/Polish CMT927A1072

Default timedisplay format

Partytimer

Day offfunction

Product literaturelanguage

Display Type

24 h – – NL, F Dutch/French CMT921A101824 h – – F French CMT921A1026

AM/PM – – UK English CMT921A1042

Page 248: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-3

Chronotherms wireless

2

3

4

5

6

7

8

10

9

11

12

13

14

HC60NG Relay box

CM920 Room unit

Relay box (1-off) with English and German literature R6660D1009

Relay box (1-off) with Dutch and French literature R6660D1017

Relay box (1-off) with French literature R6660D1025

Relay box (1-off) with Spanish literature R6660D1033

Relay box (1-off) with UK literature R6660D1041

Relay box (1-off) with Italian literature R6660D1058

7-day Room unit spare (Belgian version) CMS927B1015

7-day Room unit spare (French version) CMS927B1023

7-day Room unit spare (Spanish version) CMS927B1031

7-day Room unit spare (UK/English version) CMS927B1049

7-day Room unit spare (Italian version) CMS927B1056

7-day Room unit spare (German/Hungarian version) CMS927B1064

7-day Room unit spare (Cz, Sk, Pol version) CMS927B1072

7-day Room unit spare (Belgian version) CMS921B1018

7-day Room unit spare (French version) CMS921B1026

7-day Room unit spare (UK version) CMS921B1042

Page 249: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-4

Chronotherms wired

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Chronotherms wired

The CM900 (CM907 or CM901) is a modern programmable room thermostat based on Honeywell's proven CM60 programming philosophy. To further improve the ease of use and assist installation, this product includes an extra large LCD display with backlighting, a dynamic text display and an 'OK' button.Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating or cooling systems.

7-day program

1-day program

Accessories

Chronotherm with extended feature set and slim ultra-modern design CM907, CM901

Power source battery powered, 2 x 1,5 V AA Alkaline cells supplied

Battery life 2 years typical for applications with loads smaller than 3 A

Switch function/capacity SPDT, 24..230 V, 50..60 Hz, 0,5..8 A resistive, 0,5..3 A inductive

Terminal max. wire size 2,5 mm2

Temp. setpoint range 5 ... 35 oC

Temperature control accuracy

0,5 oC

Control functions Proportional + Integral (PI) temperature control

Temperature setpoints per day

6 independent temperature setpoints

Time setting resolution time of day - 1 minute, program - 10 minute steps

Heating /Cooling application H or C

Manual operation functions manual setpoint setting (MAN) and frost protection (OFF) modes available

Housing (HxWxD) 89 mm; 133 mm; 26 mm

Holiday mode yes

Optimisation yes

Additional description • LCD backlight• automatic summer/winter time change• user program stored in non-volatile memory• input for remote temperature sensor or outside temperature sen-

sor• input for telephone interface connection• installers set-up mode

Default timedisplay format

Partytimer

Day offfunction

TRV-mode

Product literaturelanguage

Display Type

24 h • • – I Italian CM907I24 h • • – NL, F Dutch/French CMT907A101724 h • – • NL, F Dutch/French CMT907A108224 h • • – F French CMT907A102524 h • • – E Spanish CMT907A1033

AM/PM • • – UK English CMT907A104124 h • • – HU, D, PO German/Hungarian/Portugese CMT907A106624 h • • – CZ, SK, PL Czech/Slovak/Polish CMT907A1074

Default timedisplay format

Partytimer

Day offfunction

TRV-mode

Product literaturelanguage

Display Type

24 h – – – I Italian CM901I24 h – – – NL, F Dutch/French CMT901A101024 h – – – F French CMT901A102824 h – – – E Spanish CMT901A1036

AM/PM – – – UK English CMT901A1044

Remote temperature sensor F42010972 001

Outside temperature sensor F42010971 001

Terminal block for telephone interface connection F42010977 001

Page 250: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-5

Chronotherms wired

2

3

4

5

6

7

8

10

9

11

12

13

14

The CM700 (CM707, CM702 or CM701) is a modern programmable room thermostat based on Honeywell's proven CM20 programming philosophy. To further improve the ease of use and assist installation, this product includes a large LCD display and an 'OK' button.Used for general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters, heat pumps etc. in heating systems.

7-day program

1+1-day program

1-day program

Chronotherm with comprehensive feature set and slim modern design CM707, CM702, CM701

Power source battery powered, 2 x 1,5 V AA Alkaline cells supplied

Battery life 2 years typical

Switch function/capacity SPDT, 24..230 V, 50..60 Hz, 0,5..5 A resistive, 0,5..2 A inductive

Terminal max. wire size 2,5 mm2

Temp. setpoint range 5 ... 35 oC

Temperature control accuracy

0,5 oC

Control functions Proportional + Integral (PI) temperature control

Time setting resolution time of day - 1 minute, program - 10 minute steps

Heating /Cooling application

Heating only

Manual operation functions

manual setpoint setting (MAN) and frost protection (OFF) modes available

Housing (HxWxD) 88,5 mm; 133 mm; 26 mm

Additional description • user program stored in non-volatile memory• installers set-up mode

Default time display format Holiday mode Temperature setpoints per day Product literature language Type24 h • 4 I, PO, E, F, D, NL CMT707A100324 h • 4 CZ, PL, SK, HU, RO, RU CMT707A1011

AM/PM • 4 UK CMT707A102924 h • 6 UK, GR, TU, CR, SL CMT707A1037

Default time display format Holiday mode Temperature setpoints per day Product literature language Type24 h – 4 I, PO, E, F, D, NL CMT702A100424 h – 6 I, PO, E, F, D, NL CMT702A1012

Default time display format Holiday mode Temperature setpoints per day Product literature language Type24 h – 4 I, PO, E, F, D, NL CMT701A1006

AM/PM – 4 UK CMT701A1014

Page 251: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-6

Chronotherms wired

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Analogue programmable thermostat with 7 day program.For general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters etc. in heating systems.

7-day analogue Chronotherm with unique wave design CM37

Power source battery powered, 2 x 1,5 V AA Alkaline cells supplied

Battery life 1 year typical

Switch function/capacity SPDT, 24..230V, 50..60Hz, 0,5..8A resistive, 0,5..3A inductive (0.6 pf)

Approvals CE

Protection class IP30

Terminal max. wire size 2,5 mm2

Temperature setpoint range comfort

10 ... 30 oC

Temperature setpoint range economy

5 ... 25 oC

Temperature control accuracy

0,5 oC

Control functions proportional + integral (PI) temperature control

Time setting resolution 1 hour, minimum setpoint change interval 2 hours

Heating /Cooling application

Heating only

Manual operation functions

override switch with: comfort, economy and auto positions

Housing (HxWxD) 90 mm; 135 mm; 29 mm

Product literature language Model TypeMulti-lingual (NL, F, D, GB, E) international T6637B1009

Italian for Italy only CM37IMulti-lingual (NL, F, D, GB, E) for Belgium only T6637B1017

Page 252: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-7

Chronotherms wired

2

3

4

5

6

7

8

10

9

11

12

13

14

Analogue programmable thermostat with 1 day program.For general purpose control of boilers, zone valves, circulation pumps, thermal actuators, electric heaters etc. in heating systems.

1-day analogue Chronotherm with unique wave design CM31

Power source battery powered, 2 x 1,5 V AA Alkaline cells supplied

Battery life 1 year typical

Switch function/capacity SPDT, 24..230V, 50..60Hz, 0,5..8A resistive, 0,5..3A inductive (0.6 pf)

Approvals CE

Protection class IP30

Terminal max. wire size 2,5 mm2

Temperature setpoint range comfort

10 ... 30 oC

Temperature setpoint range economy

5 ... 25 oC

Temperature control accuracy

0,5 oC

Control functions proportional + integral (PI) temperature control

Time setting resolution 15 minutes, minimum setpoint change interval 15 minutes

Heating /Cooling application

Heating only

Manual operation functions

override switch with: comfort, economy and auto positions

Housing (HxWxD) 90 mm; 135 mm; 29 mm

Product literature language Model TypeMulti-lingual (NL, F, D, GB, E) international T6631B1005

Italian for Italy only CM31IMulti-lingual (NL, F, D, GB, E) for Belgium only T6631B1021

Page 253: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-8

Room thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Room thermostats

Digital non-programmable thermostat with large LCD display and simple user interface.For general purpose control of boilers, zone valves, pumps, thermal actuators, electric heaters and fan-coil units.

• self-learning TPI Fuzzy logic control• adjustable proportional band• adjustable on/off time• frost protection• setpoint limits• fail-safe operation• installer mode

Digital room thermostat, DT90

Approvals CE

Protection class IP30

Switch function/capacity SPDT 24..230 Vac, 8 A resistive, 3 A inductive; potential free

Power source battery powered, 2 x 1,5 V AA Alkaline cells

Battery life minimum 2 years

Terminal max. wire size 2,5 mm2

Temp. setpoint range 5 ... 35 oC

Control output signal on/off

Manual operation functions

-off/standby, -setpoint, -ECO

Heat/Cool manual mode H/C

Product literature language

multilanguage user guide included in package

Earthing double insulated

Housing (HxWxD) 92 mm; 90 mm; 27 mm

Model Typestandard DT90A1008with ECO button for up to 24h energy-saving setback DT90E1012

Page 254: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-9

Room thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Room thermostat and relay box, with 2-way RF-communication between these units. The thermostat is non-programmable; it has a large LCD display and simple user interface.For general purpose control of boilers, zone valves, pumps, thermal actuators, electric heaters and fan-coil units.

• self-learning TPI Fuzzy logic control• adjustable proportional band• adjustable on/off time• frost protection• setpoint limits• fail-safe operation• installer mode• transmission and signal strength features

Thermostat with relay box

Spare units

Wireless room thermostat, DT92

Approvals CE

Protection class IP30

Switch function/capacity relay box with SPDT-switch 24..230 Vac, 5 A resistive, 3 A inductive; potential free

Power source • relay box: 230 V, 1 VA• thermostat: battery powered, 2 x 1,5 V AA Alkaline cells

Battery life minimum 2 years

Terminal max. wire size 2,5 mm2

Temp. setpoint range 5 ... 35 oC

Control output signal on/off

Manual operation functions

-off/standby, -setpoint, -ECO

Display functions thermostat:• room temperature, setpoint, off/standby mode, relay status,

RF communication, ECO mode and countdown• frost protection, internal fault, battery low, loss of RF commu-

nication

LED functions relay box:• green LED for relay on/off status, transmission test• red LED for status in RF binding or reset modes, loss of RF

communication

Product literature language

multilanguage user guide included in package

Earthing double insulated

Housing (HxWxD) 92 mm; 90 mm; 27/30,5 mm

Model Typestandard DT92A1004with ECO button for up to 24h energy-saving setback with adjustable setpoint DT92E1000

Thermostat, standard DTS92A1011

Thermostat, with ECO button DTS92E1020

Relay box BDR91A1000

Relay box for UK BDR91T1004

Page 255: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-10

Room thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wall mounted line voltage room thermostat.For frost protection of building fabric, contents, and exposed pipework.

Accessories

Room thermostat 230Vac with SPST output, T4360A frost protect

Approvals CE

Protection class IP30

Terminal max. wire size 4 mm2

Suitable for frost protect

Temp. setpoint range 0 ... 20 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator no

Heating /Cooling application

Heating only

Switch function/capacity 10(3) A

Earthing double insulated

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Additional description Can be used in conjunction with L641B1004 pipe mounted thermostat to provide frost protection system for pipework. T4360A brings on heating in response to reduced temperatures, and L641B switches heating off when pipes have warmed up.

Tamperproof cover Product literature language Typeyes English T4360A1009yes Multilingual T4360A1017

supplied English T4360A1025

Range stops for limitation of setpoint adjustment (20 pieces) F42006646 001

Wall-plate to allow mounting onto different wall-boxes F42007789 001

Frost protection kit, comprising T4360A + L641B K42008268-001

Page 256: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-11

Room thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Wall mounted line voltage room thermostat.For special applications involving control of gas valves, zone valves, circulation pumps, ventilators, boilers etc. in heating systems.

Accessories

Room thermostat 230Vac with SPST output, T4360 heat

Approvals CE

Protection class IP30

Terminal max. wire size 4 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heating /Cooling application

Heating only

Earthing double insulated

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Additional description Lamp is supplied potential free, and can be wired to indicate operating mode, or boiler lock out.

Suitable for Heatanticipator

Manualoperationfunctions

Switchfunction/capacity

Lampfunction

Temperaturescale

Tamperproofcover

Productliteraturelanguage

Type

electric heat – – 16 A – – – Multilingual T4360B1007electric heat – – 16 A – – – English T4360B1015electric heat – – 16 A heating on – – Multilingual T4360B1031electric heat – – 16 A – 1..5 – English T4360B1080electric heat – – 16 A – – supplied English T4360B1098

heating • on/off switch 10(3) A – – – Multilingual T4360C1021night setback • on/off switch 10(3) A – – – Multilingual T4360C1039night setback • – 10(3) A – – – Multilingual T4360E1000night setback • – 10(3) A – – – English T4360E1018

thermalactuator

• – 2(2) A – – – Multilingual T4360F1008

Range stops for limitation of setpoint adjustment (20 pieces) F42006646 001

Opaque tamperproof cover to prevent thermostat from damage F42007110 001

Transparent tamperproof cover to prevent thermostat from damage F42007110 002

Wall-plate to allow mounting onto different wall-boxes F42007789 001

Page 257: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-12

Room thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wall mounted line voltage room thermostat.For special applications involving manual heat/cool changeover in heating or cooling systems.

Accessories

Room thermostat 230Vac with SPST output, T4360 heat/cool

Approvals CE

Protection class IP30

Terminal max. wire size 4 mm2

Suitable for changeover

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator no

Heating /Cooling application

H or C

Heat/Cool manual mode H/C

Switch function/capacity 6(2) A

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Additional description Lamp is supplied potential free, and can be wired to indicate operating mode or other function.

Lamp function Type– T4360D1003wiring dependent T4360D1011

Range stops for limitation of setpoint adjustment (20 pieces) F42006646 001

Opaque tamperproof cover to prevent thermostat from damage F42007110 001

Transparent tamperproof cover to prevent thermostat from damage F42007110 002

Wall-plate to allow mounting onto different wall-boxes F42007789 001

Page 258: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-13

Room thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Wall mounted line voltage room thermostat.For general purpose control of gas valves, zone valves, circulation pumps, ventilators, boilers etc. in heating or cooling systems.

Accessories

Room thermostat 230 Vac, with SPDT output, T6360

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230 Vac, heating terminal 10 A resistive, 3 A inductive; cooling terminal 6 A resistive, 2 A inductive

Terminal max. wire size 4 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heating /Cooling application

H or C

Earthing double insulated

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Additional description Lamp is generally supplied potential free, and can be wired to indicate heating or cooling operation, or boiler lockout.

Heat anticipator Manual operationfunctions

Lamp function Temperaturescale

Tamperproofcover

Product literaturelanguage

Type

– – – – – Multilingual T6360A1004– – wiring dependent – – Multilingual T6360A1012• – – – – Multilingual T6360B1002• – wiring dependent – – Multilingual T6360B1010• – – – – English T6360B1028• – heating on – – English T6360B1036• – – – yes English T6360B1069• – – 1..5 – English T6360B1085• – – – yes Multilingual T6360B1093• – – – supplied English T6360B1168– on/off switch – – – Multilingual T6360C1000– on/off switch wiring dependent – – Multilingual T6360C1018

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Opaque tamperproof cover to prevent thermostat from damage F42007110 001

Transparent tamperproof cover to prevent thermostat from damage F42007110 002

Wall-plate to allow mounting onto different wall-boxes F42007789 001

Page 259: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-14

Room thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wall mounted low voltage room thermostat, with gold-plated contacts and series 18 ohm anticipator.For low voltage control of zone valves, circulation pumps, boilers, etc.

Accessories

Room thermostat 24Vac with SPST output, T8360

Approvals CE

Protection class IP30

Switch function/capacity SPST 24Vac, 88..127 mA with series anticipator connected

Terminal max. wire size 4 mm2

Temp. setpoint range 10 ... 30 oC

Differential fixed 1 oC

Temperature element vapour filled

Temp. element place built in

Heat anticipator yes

Heating /Cooling application

Heating only

Product literature language

Multilingual

Earthing double insulated

Housing (HxWxD) 83 mm; 83 mm; 40 mm

Additional description Switch rating of 10..500 mA if series anticipator is not connected, by wiring input to terminal 1.

TypeT8360A1000

Range stops, to limit setpoint adjustment (20 pieces) F42006646 001

Opaque tamperproof cover to prevent thermostat from damage F42007110 001

Transparent tamperproof cover to prevent thermostat from damage F42007110 002

Wall-plate to allow mounting onto different wall-boxes F42007789 001

Page 260: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-15

Water thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Water thermostats

Surface mounting thermostat for applications with hot water storage cylinders or water pipes.For temperature control of hot water storage cylinders, high and low temperature limiting on water pipes, and automatic heat/cool changeover for 2-pipe fan-coil systems.

Water temperature control thermostat, 230Vac, SPDT output, L641

Approvals CE

Protection class IP30

Switch function/capacity SPDT 230Vac, 4 A resistive, 2 A inductive

Wiring connection Screw terminals (x3)

Terminal max. wire size 1,5 mm2

Differential fixed 10 oC

Media temp. 0 ... 95 oC

Ambient temperature 0 ... 70 oC

Temperature element bimetal

Housing (HxWxD) 79 mm; 44 mm; 54 mm

Additional description Thermostat delivered with mounting strap for cylinders (L641A) or mounting springs for pipes (L641B).

• A manual setting knob is supplied with L641A.• A tamperproof cover is supplied with L641B.

Suitable for Temp. setpoint range Mounting place Tamperproof cover TypeoC

water temperature control 40 ... 80 on cylinder – L641A1039low limit or H/C changeover 2 ... 40 strap on pipe supplied L641B1004

high limit 50 ... 95 strap on pipe supplied L641B1012

Page 261: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-16

Timers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Timers

Electronic 2 zone timers with digital display and linked heating and hot water time programmes.For hydronic central heating applications.

Digital timer 230Vac SPST outputs, ST699/799

Approvals CE

Protection class IP20

Power supply 230 Vac; 10 VA

Control output relays

Switch function/capacity 2 x SPST output 230Vac, 3 A resistive, 3 A inductive ratings

Terminal max. wire size 1,5 mm2

Time setting resolution 1 min. for clock, 10 min. for programmes

Memory back-up battery back-up maintains programmes and real time for 7 days

LED functions indicate zone on/off

Modes of operations off/cont/twice/once

Number of outputs for zones

2

Programmed on/off periods per day

2

Product literature language

English

Earthing double insulated

Housing (HxWxD) 100 mm; 100 mm; 38 mm

Additional description ST699/799 time controls have built-up startup programme, temporary override facilities, and choice of AM/PM or 24-hour clock display. ST799 model has LCD backlighting.

Clock functions Type1 day ST699B10027 day ST799A1003

Page 262: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-17

Timers

2

3

4

5

6

7

8

10

9

11

12

13

14

The ST9000 family of electronic time controls is a range of market leading products that covers all applications from 1 day control of combi boilers to 7 day control of central heating and stored hot water systems, and also 2 zone time control.All products have a line of text feature, with a large backlit display to make them extremely user-friendly. A factory set clock/date and automatic 1hour summer/winter time change are designed to further enhance ease of use. With a modern fresh look that complements any decor style, and range of valued features for Users and Installers alike, the ST9000 family is intended to control comfort with economy in modern heating systems.

1 channel

2 channel

Family of timers and programmers, ST9000 series

Approvals CE

Protection class IP30

Power supply 230 Vac; 10 VA

Control output relays

Switch function/capacity contact output 230Vac, 3 A resistive, 3 A inductive ratings

Terminal max. wire size 2,5 mm2

Time setting resolution 1 min. for clock, 10 min. for programmes

Memory back-up Settings and parameters stored in NVRAM. In-built battery maintains factory-set date and time for installation and backup for up to 9000 hours of power cuts. Additional super-capacitor provides emergency backup for more than 1.5 hours.

LED functions indicate zone on/off

Modes of operations off/auto/once/cont

Earthing double insulated

Housing (HxWxD) 99 mm; 145 mm; 35 mm

Additional description All models with Installer set-up, 3 programs, and buttons for Override and Extra hour

• C-models: Day and Copy Day, Holiday mode • S-models: Service mode with telephone number display and

PIN-code access protection

Product description Programmed on/off periods per day Outputs Type1 day timer 2 1xSPDT ST9100A10087 day timer 3 1xSPDT ST9100C1006

1 day service timer 2 2xSPST ST9100S1007

Product description Programmed on/off periods per day Outputs Type1 day, 2 channel programmer 2 2xSPDT ST9400A10027 day, 2 channel programmer 3 2xSPDT ST9400C1000

1 day, 2 channel service programmer 2 2xSPDT ST9400S10017 day, 2 zone timer 3 2xSPDT ST9500C1015

Page 263: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-18

Timers

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The Sundial RF2 systems consist of several wireless enabled components: a timer/programmer from the ST9020 series, and a combination of DT92 room thermostat and/or CS92 cylinder thermostat.The ST9020 range is an extension to the ST9000 family to cover wireless applications. Each ST9020 product is wireless enabled, with a built in wireless transceiver. This allows it to communicate with wireless room thermostats, cylinder thermostats and other RF devices to form a complete Sundial RF2 control system that is energy efficient and compliant with Building Regulations.The time control is mains powered and does the control and switching of the system components such as boilers, pumps and zone valves. It therefore acts as the hub of the system and once connected allows simple installation of the wireless room thermostat (DT92E) or cylinder thermostat (CS92A).Sundial RF2 can be used to upgrade older systems that do not have boiler interlock in the form of a room thermostat or cylinder thermostat, as well as being suitable for new installations. There are 5 packs designed to cover applications with combi-boiler systems, 2-zone systems, and systems with stored hot water tanks. These systems can be extended to allow remote wireless control of valves and/or boilers using the wireless relay box BDR91T. Pack 5 also has an OpenTherm low voltage output for modulating control of the boiler.

Wireless Heating and Hot Water Control Systems, Sundial RF2

Approvals CE

Protection class IP30

Power supply • time control ST9020: 230 Vac / 10 VA• thermostats DT92/CS92: battery-powered, 2 x 1.5 V AA Alka-

line cells

Control output relays

Switch function/capacity contact output 230Vac, 3 A resistive, 3 A inductive ratings

Terminal max. wire size 2,5 mm2

Time setting resolution 1 min. for clock, 10 min. for programs

Memory back-up • all products: settings and parameters stored in NVRAM• ST9020: battery maintains factory-set date and time for instal-

lation and backup for up to 9000 hours of power cuts• ST9020: super-capacitor provides emergency backup for

more than 1.5 hours

LED functions • ST9020: indicates on/off status of zone control relays• CS92: used for RF binding, indication of signal strength and

fault conditions

Modes of operations off/auto/once/cont

Additional description All products have:• 2-way RF communication• installer mode• optimization (optimum start, delayed start, optimum stop)• service mode with telephone number display and PIN-code ac-

cess protection• holiday mode• override buttons extra hour and override

Page 264: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-19

Timers

2

3

4

5

6

7

8

10

9

11

12

13

14

Sundial RF2 Pack 1

Sundial RF2 Pack 2

Sundial RF2 Pack 3

Sundial RF2 Pack 4

Sundial RF2 Pack 5

Spare units

Application information Includes TypeCombi boiler ST9120C+DT92E Y9120H2009

Application information Includes TypeSystem boiler, with stored DHW and existing wired DHW

thermostatST9420C+DT92E Y9420H1008

Application information Includes TypeSystem boiler, with stored DHW without existing wired DHW

thermostatST9420C+DT92E+CS92A Y9420S2005

Application information Includes TypeStored DHW systems ST9120C+CS92A Y9120W1000

Application information Includes TypeCombi boiler with 2 heating zones ST5020+DT92E+DT92E Y9520Z1007

7 day single channel wireless timer ST9120C1003

7 day 2 channel programmer ST9420C1008

7 day 2 zone timer ST9520C1005

Wireless room thermostat DTS92E1020

Wireless DHW thermostat CS92A1007

Wireless relay box BDR91T1004

Page 265: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

11-20 http://products.ecc.emea.honeywell.com/europe

Page 266: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Zoning control Page

Wireless 12-2

Page 267: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-2

Wireless

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Wireless

Multi-zone controller providing a very explanatory touch-screen display for intuitive operation by finger tip or touch-pen. Available both as a table or wall device. A total of up to eight individual temperature zones and time programs can be set up. The controller is part of the evohome individual room control system and therefore also equipped with the proven wireless RF (868 MHz) technology.Control system for radiators, underfloor heating and mixing valves in home or office environment with optional control for boiler and heat pump.

• evotouch controller for individual zoning control up to 8 zones• intuitive local language operating menu structure and user guided programming• large touch screen display with easy to read zone and temperature information; backlit display• modern design with exchangeable front covers in polished black, brushed metal and gloss white• simple binding operation to reduce installation time and cost• proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)• prepared for new functionalities via PC link• optimized heating control• evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH

Evohome for Western European regions

Evohome for Nordic and Eastern European regions

Accessories for evotouch

Wireless individual room control system evohome

More Information http://www.evohome.info

Product description Typeevotouch + BDR91 + desk mount (chronotherm) EU plug ATP921G1034evotouch + BDR91 + desk mount (chronotherm) UK plug ATP921G1080UK Sundial pack ATP921H1004evotouch + 3 zones + BDR91 + desk mount ATP923G1064evotouch + 4 zones + desk mount (apartment) ATP924G1002evotouch + 4 zones + BDR91 + desk mount ATP924G1010evotouch + 5 zones + ATF400 + desk mount (apartment) ATP925G1058evotouch + 6 zones + BDR91 + ATF400 + desk mount ATP926G1050evo room unit/spare ATC928G1000

Product description Typeevohome package ATP924G1018evotouch room unit, desk stand and BDR ATP921G1052evotouch room unit/spare ATC928G1026

Table stand with power supply and EU power cord ATF100

Table stand with power supply and UK power cord ATF200

Wall pack with power supply ATF300

3 interchangable front covers (polished black, brushed metal, high-gloss white) ATF400

Page 268: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-3

Wireless

2

3

4

5

6

7

8

10

9

11

12

13

14

evohome components

Actuators

Underfloor heating 5 zone controller, analog output boiler (apply HRA80) HCE80

Underfloor heating 5 zone controller, relay output boiler (apply HRA80) HCE80R

Underfloor heating 5 zone controller, analog output boiler (with antenna) HCC80

Underfloor heating 5 zone controller, relay output boiler (with antenna) HCC80R

Active antenna for HCE80/HCE80R HRA80

OpenTherm bridge R8810A1018

Underfloor heating submodule for 3 additional zones HCS80

Room sensor HCF82

Room sensor with setpoint adjustment HCW82

Digital Room sensor/setpoint adjustment unit DTS92A1011

Digital Room sensor/setpoint adjustment unit with ECO DTS92E1020

Mixing valve controller HM80

Radiator controller HR80

Relay module 5 A BDR91A1000

HC60NG relay box (English/German literature) R6660D1009

Sensor-module for sun-intensity and outdoor temperature HB85

Gateway Serial Interface HGS80

Actuator Normally Open MT4-230-NO

Actuator Normally Closed MT4-230-NC

Page 269: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-4

Wireless

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. In case time programs are needed, use the central operator unit CM67z.

• 2 push button operation• configuration switch for thermoactuators normally open/closed• error display via blinking zone LED• status display for valve open = green zone LED on• RF communication check• up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna

With analog output for boiler feedback

With relay output

Accessories

Package

RF underfloor heating zone control system HCE80

Control software self learning fuzzy logic room temperature control

Hardware inputs • connection for external antenna HRA80• heating/cooling contact

Hardware outputs • 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230

• output for pump control• for HCE80, HCC80: analog output for boiler feedback (MCR40,

MCR200, Panther, Tiger, Smile, ZG252) • for HCE80R, HCC80R: relay output (potential free contact 42 V

for boiler control)

Mounting DIN-rail or wall

Type of terminals removable connectors with clip contact

Power supply 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)

More Information http://ufh.ecc.emea.honeywell.com

Product description TypeUnderfloor heating controller (apply external antenna HRA80) HCE80Underfloor heating controller, with internal antenna HCC80

Product description TypeUnderfloor heating controller (apply external antenna HRA80) HCE80RUnderfloor heating controller, with internal antenna HCC80R

Product description TypeSubmodule for 3 additional zones HCS80Room sensor HCF82Room sensor and setpoint adjustment HCW82Active antenna for HCE80/HCE80R HRA80

Product description Type1x HCE80, 1x HRA80, 3x HCW82, 4x MT4-230-NC HPF80

Page 270: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-5

Wireless

2

3

4

5

6

7

8

10

9

11

12

13

14

Additional Control units

Actuators

Wireless universal mixing valve controller for heating or cooling zone control. The controller receives heat demand signals (RF 868,3 MHz)from thermostats CM67RFMV or CM67z.The CM67RFMV also provides parameter settings for: minimum water temperature setpoint, mixing valve runtime, pump after running ime and heating or cooling operation mode.

Controller

Packages

Additional products for HM80

Central control unit, with 2 time programs, CM67z T6667Z1072

Wireless programmable control unit with 7-day clock for usage with HCE80, YZ667A1011, R6660D1017

CMS927B1015

Electronic radiator controller HR80

Relay module for boiler interlock HC60NG R6660D1009

Actuator Normally Open MT4-230-NO

Actuator Normally Closed MT4-230-NC

Universal mixing valve controller

Control output signal • 2x 230 V (3 A) on relay contacts for mixing valve open/close (not potential free contacts!)

• 230 V (3 A) on relay contact for pump on/off (not a potential free contact!)

Control functions room temperature control; water temperature control (optional)

Manual operation functions

push buttons for valve open/close

LED functions mixing valve open/close: red/green; pump on: green; and several error messages: red

Power supply 230 V;50Hz; max. 1380 VA

RF communication distance

30 m

Blocking immunity Receiver class 2 (ETSI EN300220-1 version 1.3.1)

Protection class IP54

Mounting DIN-rail or wall

Housing (HxWxD) 161,5 mm; 121 mm; 46 mm

Product description TypeUniversal mixing valve controller HM80

Product description Type1x CM67RFMV, 1x HM80, 4x Eurofix cable glands HMC801x CM67RFMV, 1x HM80, 4x Eurofix cable glands, 1x T7414C1012 HMC82

Chronotherm room thermostat CM67RFMV

Flow temperature sensor (optional) T7414C1012

Page 271: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-6

Wireless

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Radiator controller with Radio Frequency communication to the CM67z thermostat.The radiator controller can be fitted with ease to any conventional radiator valve (Honeywell, Braukmann, MNG, Heimeier, Danfoss RA etc.).

Central operating units

Accessories

Valve adapters for HR80

RF Electronic radiator controller HR80

Control functions room temperature control, energy savings and self monitoring functions for protection against valve plock and frost

Temp. setpoint range 8 ... 28 oC

Temperature element NTC20k

Temp. element place built in

Frost protection temperature

6 oC

Shut-off facility yes

Stroke 3,2 mm

Batteries included 2 x AA

Housing (HxWxD) 80 mm; 50 mm; 105 mm

TypeHR80

Operating unit for 2 zones, CM67z T6667Z1072

Protection cap for HR80 HVS80

Power supply transformer HTU10

Power supply cabinet mounting HTS10

RF handheld for mobile system control HRD80

Vaillant HCA1VEL

Oventrop HU01

Herz HR HU02

Danfoss RAV/RAVL/RA EVA1-DANFOSS

Page 272: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-7

Wireless

2

3

4

5

6

7

8

10

9

11

12

13

14

The wireless room thermostat HCW80 sends heat demand signals (RF 868,3 MHz) to the relay module HC60NG. It can be used to control gas and oil boilers, a variety of valves and actuators, or electrical heating systems.

Package

HC60NG Relay box

Wireless room thermostat for heating

Approvals EN60730-1, EN55014-1, EN55014-2, ETSI EN300220-3, ETSI EN301489

RF communication distance

30 m

Blocking immunity Receiver class 2 (EN300220-1)

Batteries included 2 x AA

Battery life 2 years typical

LED functions heat demand on/off, battery status

Housing (HxWxD) 105 mm; 98 mm; 30 mm

Protection class IP30

Temp. setpoint range 5 ... 30 oC

Additional description Setpoint scale with frost protection symbol and small pins for limitation of the adjustment range.

Product description TypeRoom thermostat HCW80

Product description Type1x HCW80, 1x R6660D009 Y6630D1007

Relay box (1-off) with English and German literature R6660D1009

Page 273: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

12-8 http://products.ecc.emea.honeywell.com/europe

Page 274: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Radiator Valves and Thermostats Page

Radiator Thermostats 13-2Thermostatic Radiator Valve Bodies 13-18Manual Valves 13-37Lockshield Valves 13-40Valves for Compact Radiators 13-45Connections for Radiator Valves 13-52

Page 275: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-2

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Radiator Thermostats

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type fulfill the European Standard EN215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30x1.5 connection are suitable for all TRV body and radiator inserts with M30x1.5 connection and 11.5mm closing dimension.

For warm water heating systems• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

Thera-100 with internal sensor

Thera-100 with remote sensor

Accessories

Thera-100 (T1000 Series) Radiator Thermostat

Approvals • A-class Energy-Efficiency certified according TELL labeling sheme• Conforms with M30 x 1.5 connection to European standard EN215

Colour white

Body-head connection M30 x 1,5

Closing dimension 11,5 mm

Temp. setpoint range 1 ... 26 oC

Zero-position yes

EN215 certified yes

Additional description • Equipped with internal wax or liquid sensor or external liquid sensor

• Over-temperature protection• Modern, ergonomical design with red economy button (EU-

version) or green economy button (GB-version) for optimal setting• Compact size

Temperature element Sensing element TELL "A" certified Typewax-filled internal – T1002W0wax-filled internal – T1002W0NA

liquid-filled internal • T1001W0GBwax-filled internal – T1002B3W0wax-filled internal – T1002B4W0

Temperature element Sensing element TELL "A" certified Typeliquid-filled remote – T100120W0liquid-filled remote – T100120B3W0

Special tool for assembly of radiator thermostats VA8210A001

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Decoring for connection nut white (RAL9016)10 pair, 20 pieces TA1000A001

Decoring for connection nut chrome 10 pair, 20 pieces TA1000A002

Theft-protection ring, white (RAL9016) TA6900A001

Page 276: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-3

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type with liquid sensor fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

Thera-200 Design

Thera-200 Design theft-protected

Accessories

Thera-200 Design (T4000 Series) Radiator Thermostat

Approvals • Conforms with M30 x 1.5 connection to European standard EN215

Sensing element internal

Body-head connection M30 x 1,5

Closing dimension 11,5 mm

Temperature element liquid-filled

Temp. setpoint range 6 ... 26 oC

Zero-position no

Design yes

EN215 certified yes

TELL "A" certified yes

Additional description • Equipped with liquid sensor• Modern ergonomical design• Compact size• Easy to clean

Colour Theft protection Typewhite/chrome – T4021white/chrome – T4021GBblack/chrome – T4321black/chrome – T4321GB

chrome/chrome – T4221chrome/chrome – T4221GB

brushed/brushed – T4111brushed/brushed – T4111GB

Colour Theft protection Typewhite/chrome • T4021V1

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

Page 277: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-4

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

• Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.

Thera-4 Classic with M30 x 1,5 connection and liquid-filled sensing element

Thera-4 Classic with M30 x 1,5 connection and remote sensing element

Thera-4 Classic with DA type connection and liquid-filled sensing element

Accessories

Thera-4 Classic (T3000 Series) Radiator Thermostat

Approvals • Conforms with M30 x 1.5 connection to European standard EN 215

• A-class Energy-Efficiency certified according TELL labeling sheme

Setpoint blocking yes

Setpoint limiting yes

Colour white

Closing dimension 11,5 mm

Temperature element liquid-filled

Additional description • Equipped with liquid sensor• Modern ergonomical design• Compact size• Easy to clean• Easy to equip with range stoppers

Body-headconnection

Sensingelement

Capillarytube length

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

m oC

M30 x 1,5 internal – 6 ... 28 – • • T3001M30 x 1,5 internal – 1 ... 28 • • • T3001W0

Body-headconnection

Sensingelement

Capillarytube length

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

m oC

M30 x 1,5 remote 2 6 ... 28 – • – T300120M30 x 1,5 remote 2 1 ... 28 • • – T300120W0

Body-headconnection

Sensingelement

Capillarytube length

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

m oC

RA-type internal – 6 ... 28 – – – T3001DARA-type internal – 1 ... 28 • – – T3001DAW0

Range stops (10 blue and 10 red) TA3000C001

Range stops (20 white) TA3000C002

Theft-protection ring, white (RAL9016) TA6900A001

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, chrome; 10 pair, 20 pieces TA1000A002

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

Special tool for assembly of thermostat VA8210A001

Page 278: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-5

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators. Radiator thermostats of this type fulfill the European Standard EN215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30x1.5 connection are suitable for all TRV body and radiator inserts with M30x1.5 connection and 11.5mm closing dimension.

• Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.

Thera-4 Design with M30 x 1,5 connection

Thera-4 Design with DA type connection

Accessories

Thera-4 Design (T2000 Series) Radiator Thermostat

Approvals • Conforms with M30 x 1.5 connection to European stan-dard EN215

• A-class Energy-Efficiency certified according TELL labeling sheme

Setpoint blocking yes

Setpoint limiting yes

Sensing element internal

Closing dimension 11,5 mm

Temperature element liquid-filled

Design yes

Additional description • Equipped with liquid sensor• Modern ergonomical design• Compact size• Easy to clean• Easy to equip with range stoppers

Body-headconnection

Colour Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

oC

M30 x 1,5 white 6 ... 28 – • • T2001M30 x 1,5 white 1 ... 28 • • • T2001W0M30 x 1,5 white/chrome 6 ... 28 – • • T2021M30 x 1,5 white/chrome 1 ... 28 • • • T2021W0

Body-headconnection

Colour Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

oC

RA-type white 6 ... 28 – – – T2001DARA-type white 1 ... 28 • – – T2001DAW0RA-type white/chrome 6 ... 28 – – – T2021DARA-type white/chrome 1 ... 28 • – – T2021DAW0

Range stops (10 blue and 10 red) TA3000C001

Range stops (20 white, RAL9016) TA3000C002

Theft-protection ring, white (RAL9016) TA6900A001

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, Chrome; 10 pair, 20 pieces TA1000A002

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

Special tool for assembly of thermostat VA8210A001

Page 279: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-6

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type with liquid sensor fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

• Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.

• Radiator Thermostats of this type with Herz (Hz) type connection are suitable for TRV bodies and valve inserts with Herz M28 x 1.5 connection and 9.5 mm closing dimension.

Thera-3 with M30 x 1,5 connection and internal sensing element

Thera-3 with M30 x 1,5 connection and remote sensing element

Thera-3 (T6000 Series) Design radiator thermostat

Approvals • Conforms with M30 x 1.5 connection to European standard EN 215

• A-class Energy-Efficiency certified according TELL labeling sheme

Setpoint blocking yes

Setpoint limiting yes

Colour white

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

Covercap

EN215certified

TELL "A"certified

Type

mm m oC

M30 x 1,5 11,5 internal – liquid-filled 6 ... 28 – Honeywell • • T6001M30 x 1,5 11,5 internal – liquid-filled 6 ... 28 – none • • T6001CM30 x 1,5 11,5 internal – liquid-filled 1 ... 28 • Honeywell • • T6001W0M30 x 1,5 11,5 internal – liquid-filled 1 ... 28 • none • • T6001W0CM30 x 1,5 11,5 internal – wax-filled 6 ... 28 – Honeywell • – T6002M30 x 1,5 11,5 internal – wax-filled 1 ... 28 • Honeywell • – T6002W0

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

Covercap

EN215certified

TELL "A"certified

Type

mm m oC

M30 x 1,5 11,5 remote 2 liquid-filled 6 ... 28 – Honeywell • – T600120M30 x 1,5 11,5 remote 2 liquid-filled 1 ... 28 • Honeywell • – T600120W0

Page 280: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-7

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Thera-3-DA with Danfoss RA-type connection and internal sensing element

Thera-3-DA with Danfoss RA-type connection and remote sensing element

Thera-3-HZ with Herz-type connection and internal sensing element

Accessories

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

Covercap

EN215certified

TELL "A"certified

Type

mm m oC

RA-type 11,5 internal – liquid-filled 6 ... 28 – Honeywell – – T6001DARA-type 11,5 internal – liquid-filled 6 ... 28 – none – – T6001DACRA-type 11,5 internal – liquid-filled 1 ... 28 • Honeywell – – T6001DAW0RA-type 11,5 internal – liquid-filled 1 ... 28 • none – – T6001DAW0C

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

Covercap

EN215certified

TELL "A"certified

Type

mm m oC

RA-type 11,5 remote 2 liquid-filled 6 ... 28 – Honeywell – – T600120DA

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

Covercap

EN215certified

TELL "A"certified

Type

mm m oC

M28 x 1,5 9,5 internal – liquid-filled 6 ... 28 – Honeywell – – T6001HZM28 x 1,5 9,5 internal – liquid-filled 1 ... 28 • Honeywell – – T6001HZW0

Decoring for connection nut white (RAL9016) 10 pair, 20 pieces TA1000A001

Decoring for connection nut, chrome; 10 pair, 20 pieces TA1000A002

Decoring, white TA1000B001

Cover cap for customer-specific logos, white TA6000A001

Theft-protection ring, white (RAL9016) TA6900A001

Special tool for assembly of thermostat VA8210A001

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Page 281: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-8

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

• Radiator Thermostats of this type with snapring (DA) type connection are suitable for TRV bodies and valve inserts with Danfoss (RA) type compatible snap connection.

For warm water heating systems• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

Thera-2 with M30 x 1,5 connection and internal sensing element

Thera-2 with M30 x 1,5 connection and internal sensing element, Eastern European version

Thera-2 with M30 x 1,5 connection and remote sensing element

Thera-2 with DA type connection and internal sensing element

Thera-2 (T9000 Series) Radiator thermostat

Approvals Conforms with M30 x 1.5 connection to European standard EN 215

Setpoint blocking yes

Setpoint limiting yes

Colour white

Cover cap Honeywell

Additional description • Available with liquid- or wax sensor• Equipped with easy to use range stoppers• Modern ergonomical design

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

mm m oC

M30 x 1,5 11,5 internal – liquid-filled 6 ... 28 – • • T9001M30 x 1,5 11,5 internal – liquid-filled 1 ... 26 • • • T9001W0M30 x 1,5 11,5 internal – wax-filled 6 ... 28 – – – T9002M30 x 1,5 11,5 internal – wax-filled 1 ... 26 • – – T9002W0

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

mm m oC

M30 x 1,5 11,5 internal – liquid-filled 6 ... 28 – • • T9001HPM30 x 1,5 11,5 internal – liquid-filled 1 ... 26 • • • T9001W0HP

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

mm m oC

M30 x 1,5 11,5 remote 2 liquid-filled 6 ... 28 – • – T900120M30 x 1,5 11,5 remote 2 liquid-filled 1 ... 26 • • – T900120W0

Body-headconnection

Closingdimension

Sensingelement

Capillarytube length

Temperatureelement

Temp. setpointrange

Zero-position

EN215certified

TELL "A"certified

Type

mm m oC

RA-type – internal – liquid-filled 6 ... 28 – – – T9001DARA-type – internal – liquid-filled 1 ... 26 • – – T9001DAW0

Page 282: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-9

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Accessories

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Radiator thermostats of this type fulfill the European Standard EN 215 when used with certified Honeywell TRV bodies.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

For warm water heating systems• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

2080 with internal sensing element

2080 with remote sensing element

Accessories

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, chrome; 10 pair, 20 pieces TA1000A002

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

Theft-protection ring, white TA6900A001

2080 (T7000) Radiator thermostat

Approvals Conforms with M30 x 1.5 connection to European standard EN 215

Setpoint blocking yes

Setpoint limiting yes

Closing dimension 11,5 mm

Colour white

Robust design yes

Body-head connection M30 x 1,5

Temperature element liquid-filled

EN215 certified yes

Sensing element Capillary tube length Temp. setpoint range Zero-position Typem oC

internal – 6 ... 28 – T7001internal – 1 ... 28 • T7001W0internal – 6 ... 21 – T7001B3

Sensing element Capillary tube length Temp. setpoint range Zero-position Typem oC

remote 2 6 ... 28 – T700120remote 2 1 ... 28 • T700120W0

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, chrome; 10 pair, 20 pieces TA1000A002

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Theft-protection ring with Allan screws TA2080A001

Special tool for assembly of thermostat VA8210A001

Page 283: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-10

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Thermostatic radiator valve head for water and air with remote sensing element. Supplied with memory clip. Concealed limiting and blocking of setpoint range, setting with memory clip. Suitable for

• all Honeywell thermostatic radiator valve bodies, and• all Honeywell valve series M, and• all thermostatic radiator valve bodies with M30 x 1,5 connection and 11,5 mm closing dimension.

For water-based heating systems and boiler applications• on the supply of air heaters,• as mixer control for underfloor heating,• for hot water storage tanks, heat exchangers or swimming pools.

Accessories

2080 WL (T7500) Thermostat with remote sensor for water and air

Setpoint blocking yes

Setpoint limiting yes

Closing dimension 11,5 mm

Colour white

Sensing element remote, water/air

Robust design yes

Body-head connection M30 x 1,5

Capillary tube length 2 m

Temperature element liquid-filled

Temp. setpoint range 20 ... 70 oC

Zero-position no

Additional description P-bands given in the literature of above valve bodies double when used with the 2080WL.

TypeT750120

Theft-protection ring with Allan screws TA2080A001

Brass sensor pocket TA2085A001

Sealing kit for installation without sensor pocket TA2085B001

Special tool for assembly of thermostat VA8210A001

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Page 284: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-11

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Thermostatic radiator valve head with remote setting element. Concealed limiting and blocking of setpoint range. Suitable for

• all Honeywell thermostatic radiator valve bodies or valve inserts, and• all Honeywell valve series M, and• all thermostatic radiator valve bodies and compact radiator valve inserts with M30 x 1,5 connection

and 11,5 mm closing dimension.For warm water heating systems

• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

Accessories

Remote Thermostat (T9500)

Setpoint blocking yes

Setpoint limiting yes

Closing dimension 11,5 mm

Sensing element remote unit

Colour white

Body-head connection M30 x 1,5

Temperature element liquid-filled

Temp. setpoint range 8 ... 28 oC

Zero-position yes

Capillary tube length Typem

2 T950120W05 T950150W0

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Page 285: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-12

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Less heating cost and more comfort with Roomtronic HR40 from Honeywell. The HR40 is an electronic radiator controller with a series of convenient functions. It heats any room as long as required by using intelligent control algorithm and time program.The HR40 radiator controller can be fitted with ease to any conventional radiator valve. For most of the conventional valves an adapter is not required (Honeywell, Braukmann, MNG, Heimeier, Junkers, Landis & Gyr, Duogyr). The HR40 is adapting itself automatically.

Controller

Controller including wall module

Valve adapters for HR40

Electronic radiator controller

Control functions an individual time program allows to set your own heating time program and setpoints for each day of the week, self-monitoring functions offer protection against valve plock and frost; it helps you to save energy or tell you that the batteries need to be changed

Clock functions the HR40 changes between 2 setpoint temperatures in terms of comfort temperature and economy temperature based on time program, the time program is free programmable to setup your individual daily program respective weekly program

Approvals meets CE standard

Temp. setpoint range 8 ... 28 oC

Temperature element NTC20k

Temp. element place built in

Frost protection temperature 6 oC

Shut-off facility yes

Stroke 3,2 mm

Batteries included 2 x AA

Housing (HxWxD) 80 mm; 50 mm; 105 mm

Product description TypeElectronic radiator controller HR40

Product description TypeElectronic radiator controller, existing of wall module with sensor and operation, and an actuator for the radiator valve, with 5 meter cable

HR40F

Electronic radiator controller, existing of wall module with sensor and operation, and an actuator for the radiator valve, with 10 meter cable

HR10F

Vaillant HCA1VEL

Oventrop HU01

Herz HR HU02

Danfoss RAV/RAVL/RA EVA1-DANFOSS

Page 286: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-13

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Thermostatic radiator valve head with additional heating element for remotely controlled temperature drop of up to 13K. Limiting and blocking of setpoint range with memory clip. Suitable for

• all Honeywell thermostatic radiator valve bodies or valve inserts, and• all Honeywell valve series M, and• all thermostatic radiator valve bodies and compact radiator valve inserts with M30 x 1,5 connection

and 11,5 mm closing dimension.For warm water heating systems

• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

Accessories

Thera-EL (T850) Radiator thermostat with remote control

Setpoint blocking yes

Setpoint limiting yes

Closing dimension 11,5 mm

Input voltage 8-24 V AC/DC, for temperature drop of 2-13K

Cable length 1,5 m

Sensing element internal

Colour white

24V heating element yes

Body-head connection M30 x 1,5

Temperature element wax-filled

Temp. setpoint range 6 ... 28 oC

Zero-position no

TypeT850V24

Theft-protection ring, white TA6900A001

Torx-Screwdriver for theft-protection ring TA6900B001

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, white (RAL9016); 1 pair, 2 pieces TA1000A011

Decoring for connection nut, chrome; 10 pair, 20 pieces TA1000A002

Decoring for connection nut, chrome; 1 pair, 2 pieces TA1000A022

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with 11.5 mm closing dimension

TA1010HZ01

Special tool for assembly of thermostat VA8210A001

Page 287: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-14

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

T100 M

Accessories

Thermostatic radiator valve head with remote liquid-filled sensing element and setting unit. Suitable for• all Honeywell thermostatic radiator valve bodies or valve inserts, and• all thermostatic radiator valve bodies and compact radiator valve inserts with M30 x 1,5 connections

and 11,5 mm closing dimension.For warm water heating systems

• on thermostatic radiator valve bodies, or• on compact radiator valve inserts.

T100 M Radiator thermostat with red economy button

Setpoint blocking yes

Setpoint limiting yes

Closing dimension 11,5 mm

Sensing element internal

Colour white

Body-head connection M30 x 1,5

Temperature element liquid-filled

Cover cap Honeywell

Temp. setpoint range Zero-position TypeoC

7 ... 27 – T100M-264F1 ... 27 • T100M-364F

Special tool for assembly of radiator thermostats VA8210A001

Decoring for connection nut white (RAL9016)10 pair, 20 pieces TA1000A001

Decoring for connection nut chrome 10 pair, 20 pieces TA1000A002

T100 MZ Radiator thermostat, remote setting unit

Setpoint blocking no

Setpoint limiting no

Closing dimension 11,5 mm

Sensing element remote unit

Colour white

Body-head connection M30 x 1,5

Temperature element liquid-filled

Temp. setpoint range 16 ... 24 oC

Zero-position no

Cover cap Honeywell

Capillary tube length Typem

2 T100MZ-25125 T100MZ-2515

Page 288: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-15

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator.

• TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Honeywell radiator thermostats with Honeywell (HW) M30 x 1.5 connection are suitable for all TRV body and radiator inserts with M30 x 1.5 connection and 11.5 mm closing dimension.

T100 R with immersion pocket for sensor

T100 RS with screw-in sensor R 1/2"

T100 RS with contact sensor

Accessories

T100R / T100RS Thermostats with remote sensor for hot water units

Setpoint blocking no

Setpoint limiting no

Closing dimension 11,5 mm

Colour white

Body-head connection M30 x 1,5

Capillary tube length 2 m

Temperature element liquid-filled

Temp. setpoint range Sensing element TypeoC

10 ... 50 remote, immersion pocket T100R-AA30 ... 70 remote, immersion pocket T100R-AB

Temp. setpoint range Sensing element TypeoC

10 ... 50 remote, screw-in sensor T100RS-DA30 ... 70 remote, screw-in sensor T100RS-DB

Temp. setpoint range Sensing element TypeoC

15 ... 50 remote, contact sensor T100R100430 ... 70 remote, contact sensor T100R1012

Theft-protection ring, white (RAL9016) TA6900A001

Decoring for connection nut, white (RAL9016); 10 pair, 20 pieces TA1000A001

Decoring for connection nut, Chrome; 10 pair, 20 pieces TA1000A002

HZ-Adapter from M28 x 1.5 with 9.5 mm closing dimension to M30 x 1.5 with TA1010HZ01

DA-Adapter from Danfoss snap connection RA to M30 x 1.5 TA1010DA01

Special tool for assembly of thermostat VA8210A001

Page 289: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-16

Radiator Thermostats

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Thermostats of this type have a theft-resistant, heavy duty design and were specially designed for use in public buildings such as offices, schools, barracks or hospitals.

• A Radiator Thermostat is installed onto a Thermostatic Radiator Valve Body (TRV body). The combination of both, the Thermostatic Radiator Valve (TRV), controls the room temperature by adjusting the flow of hot water through a radiator. TRVs are installed in water-based heating systems on the supply or, less commonly on the return connection of radiators.

• Honeywell radiator thermostats with Honeywell (HW) M30x1.5 connection are suitable for all TRV body and radiator inserts with M30x1.5 connection and 11.5mm closing dimension.

Thermostat restists extreme loads• Thermostat can only be removed with special tool • Setting with setpoint numerics• Adjustment of the fixid setpoint with a setting key (T100V-101 and T100VM-101 only)• Lock disk against unauthorized adjustment (T100V-101 and T100VM-101 only)• Reliable wax-filled sensing element

Temperature range fixed with lock disk

Temperature range variable

Accessories

T100V/T100VM Heavy-Duty Radiator Thermostat

Setpoint blocking no

Closing dimension 11,5 mm

Sensing element internal

Colour white

Robust design yes

Theft protection yes

Body-head connection M30 x 1,5

Temperature element wax-filled

Zero-position no

Additional description Thermostat can only be removed with special tool (WT100V) and is reusable.

Temp. setpoint range Setpoint limiting Suitable for TypeoC

6 ... 26 • V100 T100V-1016 ... 26 • V2000 T100VM-101

Temp. setpoint range Setpoint limiting Suitable for TypeoC

6 ... 20 – V100 T100V-2416 ... 20 – V2000 T100VM-241

Special tool to remove thermostats WT100V

Screw lock, 5 pieces, for T100V-101 and T100V-241 AS100V

Screw lock, 5 pieces, for T100VM-101 and T100VM-241 AS100VM

Lock disk 5, pieces, for T100V-101 and T100VM-101 FS100V

Page 290: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-17

Radiator Thermostats

2

3

4

5

6

7

8

10

9

11

12

13

14

Return-temperature limiting thermostat with internal element. Good readability from every angle. Limiting and blocking of setpoint range without tools.The Thera-RTL limits the return flow temperature of radiators or, in case of combined radiator/underfloor heating systems, the return flow temperature of underfloor heating loops.

Accessories

Underfloor sets for the control of underfloor heating loops by return temperature or ambient temperature. Set 1 and 2 also for combined radiator/underfloor heating loops.For underfloor heating loops or combined radiator/underfloor heating loops.

Thera-RTL (T6102) Return temperature limiter

Setpoint blocking yes

Setpoint limiting yes

Body-head connection M30 x 1,5

Closing dimension 11,5 mm

Temp. element place internal

Temperature element wax-filled

Colour white to RAL9016

Temp. setpoint range 20 ... 50 oC

TypeT6102

Cover ring, white TA1000A001

Trim ring, white TA1000B001

Theft-protection ring, white TA6900A001

Special screwdriver for theft-protection ring TA6900B001

Underfloor heating control sets for underwall installation (T6101, T6102)

Setpoint blocking yes

Setpoint limiting yes

Medium type water or water-glycol mixture according to VDI 2035

Max. operating pressure 10 bar

Max. delta P 1 bar

Colour white to RAL9016

Additional description Suitable connections see 'Connections for Radiator Valves'.

Product description Temp. setpoint range Kvs value TypeoC

Set 1 - Return temperature limiter with visible thermostat 20 ... 50 1 T6102RUB15Set 2 - Return temperature limiter with concealed thermostat 20 ... 50 1,7 T6102AUB15

Set 3 - Room Control-Set 6 ... 28 1 T6101RUB15

Page 291: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-18

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Thermostatic Radiator Valve Bodies

The new Honeywell Design Line is particularly styled for use with design radiators. With their high class appearance they perfectly fit to all kinds of ambients.

• Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat exchangers. Together with a radiator thermostat, for example the Thera-4, they control the room temperature by regulating the flow of hot water into the radiator. The temperature of different rooms is controlled individually and energy is saved.

• TRV bodies of this type have quiet operation and are fitted to the supply or return of radiators on two-pipe systems with medium flow rates.

Water or water-glycol mixture, quality to VDI 2035

Design white

Design chrome

Service parts

Thera Design Edition - TRV Body

Materials Valve housing made of brass with chrome or white (RAL 9016) surface; Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle; Protection cap made of plastic; Union-nut and tailpiece made of chrome plated brass with EPDM O-ring

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-setting yes

Design yes

DN size 15 mm

Heat exchanger connection 1/2 inch

Body pattern Colour Typeangle white V2081ESL15

straight white V2081DSL15double angle right white V2081RSL15

double angle left white V2081LSL15

Body pattern Colour Typeangle chrome V2082ESL15

straight chrome V2082DSL15double angle right chrome V2082RSL15

double angle left chrome V2082LSL15

Replacement valve insert VS1200SLGB01

Service tool to replace valve insert VA8200A001

Page 292: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-19

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Valve accessories

Accessories - Pipe connections

Manual design handwheel, white (RAL9016) VA2200C001

Manual design handwheel, chrome VA2200C002

Rosette white (RAL9016) for wall covering; 40 x 12mm VA2201D012

Rosette white (RAL9016) for wall covering; 40 x 14mm VA2201D014

Rosette white (RAL9016) for wall covering; 40 x 15mm VA2201D015

Rosette white (RAL9016) for wall covering; 40 x 16mm VA2201D016

Rosette white (RAL9016) for wall covering; 40 x 18mm VA2201D018

Rosette white (RAL9016) for wall covering; 40 x 20mm VA2201D020

Rosette chrome for wall covering; 40 x 12mm VA2201E012

Rosette chrome for wall covering; 40 x 14mm VA2201E014

Rosette chrome for wall covering; 40 x 15mm VA2201E015

Rosette chrome for wall covering; 40 x 16mm VA2201E016

Rosette chrome for wall covering; 40 x 18mm VA2201E018

Rosette chrome for wall covering; 40 x 20mm VA2201E020

Connection for copper pipe (1 pcs.); 24 x 19 x 12mm VA720C1200

Connection for copper pipe (1 pcs.); 24 x 19 x 14mm VA720C1400

Connection for copper pipe (1 pcs.); 24 x 19 x 15mm VA720C1500

Connection for copper pipe (1 pcs.); 24 x 19 x 16mm VA720C1600

Connection for PE-X pipe (1 pcs.); 24 x 19 x 12 x 1,1mm VA721C1211

Connection for PE-X pipe (1 pcs.); 24 x 19 x 14 x 2mm VA721C1420

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 1,5mm VA721C1615

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 2mm VA721C1620

Connection for PE-X pipe (1 pcs.); 24 x 19 x 18 x 2mm VA721C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 14 x 2mm VA722C1420

Connection for multilayer pipe (1 pcs.); 24 x 19 x 16 x 2mm VA722C1620

Connection for multilayer pipe (1 pcs.); 24 x 19 x 18 x 2mm VA722C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 20 x 2mm VA722C2020

Page 293: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-20

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise thermostatic radiator valve body with broad band (BB) type valve cartridge. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based heating systems.

BB type TRV bodies to EN215 (D)

BB type TRV bodies to EN215 (F)

BB type TRV Body (V2000BB)

Materials Valve housing made of matt nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of black plastic. Union-nut and tailpiece made of nickel-plated brass.

Approvals EN215 - for details see 'http://www.cert-trv.cenorm.be/'.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Colour of protection cap black

Kvs value 0,62

Port connection internal threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern Place ininstallation

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to DIN supply 10 3/8 3/8 • V2000EBB10angle to DIN supply 15 1/2 1/2 • V2000EBB15angle to DIN supply 20 3/4 3/4 • V2000EBB20

straight to DIN supply 10 3/8 3/8 • V2000DBB10straight to DIN supply 15 1/2 1/2 • V2000DBB15straight to DIN supply 20 3/4 3/4 • V2000DBB20

Body pattern Place ininstallation

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to NF supply 10 3/8 3/8 • V2020EBB10angle to NF supply 15 1/2 1/2 • V2020EBB15angle to NF supply 20 3/4 3/4 – V2020EBB20

straight to NF supply 10 3/8 3/8 • V2020DBB10straight to NF supply 15 1/2 1/2 • V2020DBB15straight to NF supply 20 3/4 3/4 – V2020DBB20

Page 294: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-21

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Other BB type TRV bodies

BB type TRV bodies for the return

Accessories

Service parts

Body pattern Place ininstallation

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle supply 10 3/8 3/8 – V2000ABB10horizontal angle supply 15 1/2 1/2 – V2000ABB15

double angle left supply 10 3/8 1/2 – V2000LBB10double angle left supply 15 1/2 1/2 – V2000LBB15

double angle right supply 10 3/8 1/2 – V2000RBB10double angle right supply 15 1/2 1/2 – V2000RBB15

swan neck supply 15 1/2 1/2 – V2000BBB15

Body pattern Place ininstallation

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle return 10 3/8 3/8 – V2000HBB10horizontal angle return 15 1/2 1/2 – V2000HBB15

straight return 10 3/8 3/8 – V2000IBB10straight return 15 1/2 1/2 – V2000IBB15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Special tool for thermostats and TRV bodies VA8210A001

BB type valve insert VS1200BB01

O-ring insert for BB type valve inserts till 1998 VS2200A001

Page 295: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-22

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise thermostatic radiator valve body with flow specialised (KV) type valve cartridge. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based two-pipe heating systems.

KV type TRV bodies to EN215 (D)

KV type TRV bodies to EN215 (F)

KV type TRV Body (V2000Kx)

Materials Valve housing made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of red, blue or green plastic. Union-nut and tailpiece made of brass, union-nut nickel-plated, tailpiece optionally nickel-plated.

Approvals EN215 - for details see 'http://www.cert-trv.cenorm.be/'.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Colour of protection cap red (K3), blue (K4) or green (K5)

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to DIN supply 10 0,14 3/8 internal threads 3/8 – V2000EK310angle to DIN supply 10 0,36 3/8 internal threads 3/8 – V2000EK410angle to DIN supply 10 0,8 3/8 internal threads 3/8 • V2000EK510angle to DIN supply 15 0,14 1/2 internal threads 1/2 – V2000EK315angle to DIN supply 15 0,36 1/2 internal threads 1/2 – V2000EK415angle to DIN supply 15 0,8 1/2 internal threads 1/2 • V2000EK515angle to DIN supply 20 0,8 3/4 internal threads 3/4 • V2000EK520

straight to DIN supply 10 0,14 3/8 internal threads 3/8 – V2000DK310straight to DIN supply 10 0,36 3/8 internal threads 3/8 – V2000DK410straight to DIN supply 10 0,8 3/8 internal threads 3/8 • V2000DK510straight to DIN supply 15 0,14 1/2 internal threads 1/2 – V2000DK315straight to DIN supply 15 0,36 1/2 internal threads 1/2 – V2000DK415straight to DIN supply 15 0,8 1/2 internal threads 1/2 • V2000DK515straight to DIN supply 20 0,8 3/4 internal threads 3/4 • V2000DK520

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to NF supply 10 0,36 3/8 internal threads 3/8 – V2020EK410angle to NF supply 15 0,36 1/2 internal threads 1/2 – V2020EK415angle to NF supply 15 0,8 1/2 internal threads 1/2 • V2020EK515

straight to NF supply 10 0,36 3/8 internal threads 3/8 – V2020DK410straight to NF supply 15 0,36 1/2 internal threads 1/2 – V2020DK415straight to NF supply 15 0,8 1/2 internal threads 1/2 • V2020DK515

Page 296: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-23

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Other KV type TRV bodies

KV type TRV bodies for the supply or return

Accessories

Service parts

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle supply 10 0,36 3/8 internal threads 3/8 – V2000AK410horizontal angle supply 10 0,8 3/8 internal threads 3/8 – V2000AK510horizontal angle supply 15 0,36 1/2 internal threads 1/2 – V2000AK415horizontal angle supply 15 0,8 1/2 internal threads 1/2 – V2000AK515

double angle left supply 10 0,36 3/8 internal threads 1/2 – V2000LK410double angle left supply 15 0,36 1/2 internal threads 1/2 – V2000LK415

double angle right supply 10 0,36 3/8 internal threads 1/2 – V2000RK410double angle right supply 15 0,36 1/2 internal threads 1/2 – V2000RK415

swan neck supply 15 0,36 1/2 internal threads 1/2 – V2000BK415swan neck supply 15 0,8 1/2 internal threads 1/2 – V2000BK515

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

angle supply orreturn

15 0,8 3/4 external threads 3/4 – V2060EK515

straight supply orreturn

15 0,8 3/4 external threads 3/4 – V2060DK515

double angle left supply orreturn

15 0,8 3/4 external threads 3/4 – V2060LK515

double angle right supply orreturn

15 0,8 3/4 external threads 3/4 – V2060RK515

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Special tool for thermostats and TRV bodies VA8210A001

KV3 type valve insert VS1200K301

KV4 type valve insert VS1200K401

KV5 type valve insert VS1200K501

Valve insert for all KV type valve inserts till 1998 VS2200A001

Page 297: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-24

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise thermostatic radiator valve body with universal band (UBG) type valve cartridge. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based heating systems.

UBG type TRV bodies to EN215 (D)

UBG type TRV body with external threads

UBG type TRV Body (V2000UB)

Materials Valve housing made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of white plastic. Union-nut and tailpiece made of nickel-plated brass.

Approvals EN215 - for details see 'http://www.cert-trv.cenorm.be/'.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Colour of protection cap white

Additional description Suitable connections 'Connections for Radiator Valves'.

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to DIN supply 10 1,7 3/8 internal threads 3/8 • V2000EUB10angle to DIN supply 15 1,85 1/2 internal threads 1/2 • V2000EUB15angle to DIN supply 20 1,95 3/4 internal threads 3/4 • V2000EUB20angle to DIN supply 25 2,2 1 internal threads 1 – V2000EUB25

straight to DIN supply 10 1,7 3/8 internal threads 3/8 • V2000DUB10straight to DIN supply 15 1,85 1/2 internal threads 1/2 • V2000DUB15straight to DIN supply 20 1,95 3/4 internal threads 3/4 • V2000DUB20straight to DIN supply 25 2,2 1 internal threads 1 – V2000DUB25

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

straight supply orreturn

15 1,6 3/4 external threads 3/4 – V2060DUB15

Page 298: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-25

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

UBG type TRV bodies to EN215 (F)

Other UBG type TRV bodies

Accessories

Service parts

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to NF supply 10 1,8 3/8 internal threads 3/8 • V2020EUB10angle to NF supply 15 1,8 1/2 internal threads 1/2 • V2020EUB15angle to NF supply 20 1,95 3/4 internal threads 3/4 – V2020EUB20

straight to NF supply 10 0,8 3/8 internal threads 3/8 • V2020DUB10straight to NF supply 15 1,1 1/2 internal threads 1/2 • V2020DUB15straight to NF supply 20 1,95 3/4 internal threads 3/4 – V2020DUB20

Body pattern Place ininstallation

DNsize

Kvsvalue

Connectiondiameter

Port connection Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle supply 10 1,2 3/8 internal threads 3/8 – V2000AUB10horizontal angle supply 15 1,2 1/2 internal threads 1/2 – V2000AUB15

double angle left supply 10 1 3/8 internal threads 1/2 – V2000LUB10double angle left supply 15 1 1/2 internal threads 1/2 – V2000LUB15

double angle right supply 10 1 3/8 internal threads 1/2 – V2000RUB10double angle right supply 15 1 1/2 internal threads 1/2 – V2000RUB15

swan neck supply 15 1,6 1/2 internal threads 1/2 – V2000BUB15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Special tool for thermostats and TRV bodies VA8210A001

UBG type valve insert VS1200UB01

O-ring insert for BB, KV and UBG type valve inserts until 1998 VS2200A001

Page 299: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-26

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Reverse-flow thermostatic radiator valve body with universal band (UBG-R) type valve cartridge. Reverse flow feature allows any kind of installation: supply or return, regular or opposite flow direction. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based heating systems.

GB type angle pattern TRV bodies

Accessories

Spare parts

GB type TRV Body (V2047)

Materials Valve body made of matt nickel-plated red bronze Rg5 to DIN 1705, valve insert made of brass with EPDM O-rings and seat sealing, spindle made of stainless steel.

Approvals EN215 - for details see 'http://www.cert-trv.cenorm.be'.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Colour of protection cap white

Body pattern angle

Place in installation supply or return

DN size 15 mm

Kvs value 2,1

Connection diameter 1/2 inch

Port connection external threads

Threads type BSP

Heat exchanger connection 1/2 inch

EN215 certified yes

Additional description • kvs-value 1,9 in reverse flow mode.• Valve is supplied with compression fitting for copper and precision

steel pipe.

Connection size Typemm

8 V2047EUB0810 V2047EUB1015 V2047EUB15

Pre-settable handwheel VA2200D001

Heavy-duty protection cap VA2202A015

Sealing ring for HD cap VA5090A015

Service tool for exchange of valve insert during operation VA8200A001

UBG-R type reverse flow valve insert VS1200UB02

Page 300: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-27

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Low-noise thermostatic radiator valve body with stroke limited (SL) type valve cartridge. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based heating systems.

SL type TRV bodies to EN215 (D)

SL type TRV bodies to EN215 (F)

Accessories

Service parts

SL type TRV Body (V2000SL)

Materials Valve housing made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of white plastic. Union-nut and tailpiece made of nickel-plated brass.

Approvals EN215 - for details see 'http://www.cert-trv/cenorm.be'.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable by stroke limitation

Colour of protection cap white

Place in installation supply

Port connection internal and external threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern DN size Kvs value Connection diameter Heat exchanger connection EN215 certified Typemm inch inch

angle to DIN 15 1,85 1/2 1/2 • V2000ESL15angle to DIN 20 1,95 3/4 3/4 • V2000ESL20

straight to DIN 15 1,85 1/2 1/2 • V2000DSL15straight to DIN 20 1,95 3/4 3/4 • V2000DSL20

Body pattern DN size Kvs value Connection diameter Heat exchanger connection EN215 certified Typemm inch inch

angle to NF 10 1,7 3/8 3/8 • V2020ESL10angle to NF 15 1,85 1/2 1/2 • V2020ESL15angle to NF 20 1,95 3/4 3/4 – V2020ESL20

straight to NF 10 1,7 3/8 3/8 • V2020DSL10straight to NF 15 1,85 1/2 1/2 • V2020DSL15straight to NF 20 1,95 3/4 3/4 – V2020DSL20

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Special tool for thermostats and TRV bodies VA8210A001

SL type valve insert VS1200SL01

Page 301: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-28

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise pre-settable thermostatic radiator valve body. Exchange of valve insert possible when system is under pressure and operating. AT-Concept. Flush function when fully open.For water-based heating systems.

VS type TRV bodies to EN215 (D)

VS type TRV bodies to EN215 (F)

VS type pre-settable TRV Body with Flush-Position (V2000VS)

Materials Valve body made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals, stainless steel spindle and plastic presetting dial. Protection cap made of beige plastic. Union-nut and tailpiece made of nickel-plated brass.

Approvals EN215

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 2 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable yes

Colour of protection cap beige

Place in installation supply

Kvs value 0,72

Port connection internal threads

Additional description Suitable connections 'Connections for Radiator Valves'.

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to DIN 10 3/8 3/8 • V2000EVS10angle to DIN 15 1/2 1/2 • V2000EVS15angle to DIN 20 3/4 3/4 • V2000EVS20

straight to DIN 10 3/8 3/8 • V2000DVS10straight to DIN 15 1/2 1/2 • V2000DVS15straight to DIN 20 3/4 3/4 • V2000DVS20

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to NF 10 3/8 3/8 • V2020EVS10angle to NF 15 1/2 1/2 • V2020EVS15angle to NF 20 3/4 3/4 • V2020EVS20

straight to NF 10 3/8 3/8 • V2020DVS10straight to NF 15 1/2 1/2 • V2020DVS15straight to NF 20 3/4 3/4 • V2020DVS20

Page 302: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-29

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Other VS type TRV bodies

Accessories

Service parts

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle 10 3/8 3/8 – V2000AVS10horizontal angle 15 1/2 1/2 – V2000AVS15

double angle left 10 3/8 1/2 – V2000LVS10double angle left 15 1/2 1/2 – V2000LVS15

double angle right 10 3/8 1/2 – V2000RVS10double angle right 15 1/2 1/2 – V2000RVS15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Precision pre-setting key for VS and FS type valve bodies VA8201FV03

Pre-setting key for VS, V, FS and FV type valve bodies VA8201FV02

VS type valve insert with flush position (AT-Concept) VS1200VS01

Page 303: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-30

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise pre-settable thermostatic radiator valve body for very low flow rates. Exchange of valve insert possible when system is under pressure and operating. AT-Concept. Flush function when fully open.For water-based heating systems.

FS type TRV bodies to EN215 (D)

FS type TRV bodies to EN215 (F)

FS type finely pre-settable TRV Body with Flush-Position (V2000FS)

Materials Valve body made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel, brown plastic pre-setting ring. Protection cap made of brown plastic. Union-nut and tailpiece made of nickel-plated brass.

Approvals EN215

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 2 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable yes

Colour of protection cap brown

Place in installation supply

Kvs value 0,51

Port connection internal threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to DIN 10 3/8 3/8 • V2000EFS10angle to DIN 15 1/2 1/2 • V2000EFS15angle to DIN 20 3/4 3/4 • V2000EFS20

straight to DIN 10 3/8 3/8 • V2000DFS10straight to DIN 15 1/2 1/2 • V2000DFS15straight to DIN 20 3/4 3/4 • V2000DFS20

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

angle to NF 10 3/8 3/8 • V2020EFS10angle to NF 15 1/2 1/2 • V2020EFS15

straight to NF 10 3/8 3/8 • V2020DFS10straight to NF 15 1/2 1/2 • V2020DFS15

Page 304: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-31

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Other FS type TRV bodies

Accessories

Service parts

Bodypattern

DN size Connectiondiameter

Heat exchangerconnection

EN215certified

Type

mm inch inch

horizontal angle 10 3/8 3/8 – V2000AFS10horizontal angle 15 1/2 1/2 – V2000AFS15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Service tool for exchange of valve insert during operation VA8200A001

Precision pre-setting key for VS and FS type valve bodies VA8201FV03

Pre-setting key for VS, V, FS and FV type valve bodies VA8201FV02

FS type valve insert with flush position (AT-Concept) VS1200FS01

Page 305: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-32

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise pre-settable thermostatic radiator valve body for very low flow rates. Exchange of valve insert possible when system is under pressure and operating. AT-Concept.For water-based heating systems.

FV type TRV bodies to EN215 (D)

Accessories

Service parts

FV type TRV Body (V2000FV)

Materials Valve body made of nickel-plated red bronze. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of brown plastic. Union-nut and tailpiece made of nickel-plated brass

Media water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 2 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable yes

Colour of protection cap brown

Place in installation supply

Kvs value 0,35

Port connection internal and external threads

Additional description Suitable connections see 'Connections for TRV Bodies'.

Body pattern DN size Connection diameter Heat exchanger connection Typemm inch inch

angle to DIN 10 3/8 3/8 V2000EFV10angle to DIN 15 1/2 1/2 V2000EFV15

straight to DIN 10 3/8 3/8 V2000DFV10straight to DIN 15 1/2 1/2 V2000DFV15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Service tool for exchange of valve insert during operation VA8200A001

Pre-setting key for V and FV type valve bodies VA8201FV01

Precision pre-setting key for V, VS, FS and FV type valve bodies VA8201FV02

Special tool for thermostats and TRV bodies VA8210A001

FV type valve insert VS1200FV01

O-ring insert for V and FV type valve inserts VS2200B001

Page 306: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-33

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Low-noise pre-settable thermostatic radiator valve body with self-closing (SC) type valve cartridge - valve closes when head is taken off. Exchange of valve insert possible when system is under pressure and operating. AT-Concept. For water-based heating systems.

SC type TRV bodies to EN215 (D)

Other SC type TRV bodies

Accessories

Service parts

SC type TRV Body (V2000SC)

Materials Valve housing made of nickel-plated red bronze or hot-forged brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindel. Protection cap made of grey plastic. Union-nut and tailpiece made of nickel-plated brass.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable yes

Colour of protection cap grey

Place in installation supply

Kvs value 0,4

Port connection internal threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern DN size (mm) Connection diameter (inch) Heat exchanger connection (inch) Typeangle to DIN 10 3/8 3/8 V2000ESC10angle to DIN 15 1/2 1/2 V2000ESC15angle to DIN 20 3/4 3/4 V2000ESC20

straight to DIN 10 3/8 3/8 V2000DSC10straight to DIN 15 1/2 1/2 V2000DSC15straight to DIN 20 3/4 3/4 V2000DSC20

Body pattern DN size (mm) Connection diameter (inch) Heat exchanger connection (inch) Typehorizontal angle 15 1/2 1/2 V2000ASC15

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Pre-setting tool for SC type valve bodies VA8201SC01

Pre-setting tool for SC type valve bodies in connection with Verafix-MES VA8201SC02

Filling cap for SC type valve bodies VA8204A001

Special tool for thermostats and TRV bodies VA8210A001

SC type valve insert VS1200SC01

O-ring insert for SC type valve inserts VS2200C001

Page 307: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-34

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Thermostatic radiator valve body with hi-flow (H) type valve cartridge. Exchange of valve insert possible when system is under pressure and operating.For water-based heating systems.

H type angle and straight TRV bodies

H type horizontal angle TRV body

Accessories

Service parts

H type TRV Body (V2050)

Materials Valve housing made of red bronze. Valve insert made of brass with EPDM O-rings and seat sealing. Spindle made of stainless steel. Protection cap made of white plastic. Union-nut and tailpiece made of brass.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 0,3 bar

Closing dimension 11,5 mm

Stroke 2,9 mm

Body-head connection M30 x 1,5

Colour of protection cap white

Port connection internal threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern Place ininstallation

DN size Kvs value Connectiondiameter

Heat exchangerconnection

Type

mm inch inch

angle supply 15 5 1/2 1/2 V2050EH015angle supply 20 7 3/4 3/4 V2050EH020angle supply 25 7 1 1 V2050EH025

straight supply 15 3,5 1/2 1/2 V2050DH015straight supply 20 5 3/4 3/4 V2050DH020straight supply 25 5 1 1 V2050DH025

Body pattern Place ininstallation

DN size Kvs value Connectiondiameter

Heat exchangerconnection

Type

mm inch inch

horizontal angle supply or return 15 5 1/2 1/2 V2050HH015horizontal angle supply or return 20 5 3/4 3/4 V2050HH020

Pre-settable handwheel VA2200D001

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

Special tool for TRV heads and bodies VA8210A001

H type valve insert VS1200H020

O-Ring insert for H type valves O-ring insert for H type valves VS2200A001

Page 308: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-35

Thermostatic Radiator Valve Bodies

2

3

4

5

6

7

8

10

9

11

12

13

14

Thermostatic radiator valve with stroke limitation, supplied with protection cap.For water-based heating systems.

Ordering Information

Service parts

MARS Series Thermostatic Radiator Valve (V305)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Pre-setting yes

EN215 certified yes

Body pattern DN size Kvs value Connection diameter Typemm inch

angle 10 1,7 3/8 V305ESLGB10angle 15 1,85 1/2 V305ESLGB15

straight 10 1,7 3/8 V305DSLGB10straight 15 1,85 1/2 V305DSLGB15

Replacement valve insert VS1200SLGB01

Replacement handwheel (10 pcs) H100-1/2D

Pressure cap for valves DN10 VA2202A010

Pressure cap for valves DN15 VA2202A015

Sealing for pressure cap VA2202A010 VA5090A010

Sealing for pressure cap VA2202A015 VA5090A015

Service tool VA8200A001

Page 309: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-36

Thermostatic Radiator Valve Bodies

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Low-noise thermostatic radiator valve with stroke limitation, supplied with protection cap.For water-based heating systems.

Ordering Information

Service Parts

VENUS Series Thermostatic Radiator Valve (V320)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Max. delta P 0,2 bar

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Pre-settable by stroke limitation

Place in installation supply

Body pattern DN size Kvs value Connection diameter EN215 certified Typemm inch

angle 10 1,7 3/8 • V320ESLGB10angle 15 1,85 1/2 • V320ESLGB15

straight 10 1,7 3/8 • V320DSLGB10straight 15 1,85 1/2 • V320DSLGB15

horizontal angle 15 1,85 1/2 – V320RSLGB15

Replacement valve insert VS1200SLGB01

Replacement handwheel H100-1/2D

Pressure cap for valves DN10 VA2202A010

Pressure cap for valves DN15 VA2202A015

Sealing ring for VA2202A010 VA5090A010

Sealing ring for VA2202A015 VA5090A015

Service tool VA8200A001

Page 310: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-37

Manual Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Manual Valves

Pre-settable manual radiator valve with non-rising handwheel and maintenance-free spindle sealing. Convertible to thermostatic operation by exchange of valve insert. Can be done at any time, also when system is under pressure and operating.For hot water heating systems.

V2605 Mira-3 with nickel-plated tailpiece

Accessories

Service parts

Mira-3 (V2605) Manual radiator valve, convertible to thermostatic operation

Materials Valve housing made of nickel-plated red bronze. Valve insert made of brass with EPDM O-rings. Handwheel made of white plastic. Threaded tailpiece and connection nut made of nickel-plated brass

Place in installation supply

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Pre-setting yes

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern DN size Kvs value Connection diameter Typemm inch

angle to DIN 10 1,5 R 3/8 V2605E0010angle to DIN 15 1,95 R 1/2 V2605E0015angle to DIN 20 2,45 R 3/4 V2605E0020

straight to DIN 10 1,3 R 3/8 V2605D0010straight to DIN 15 1,7 R 1/2 V2605D0015straight to DIN 20 2,2 R 3/4 V2605D0020

Tamper-proof cap VA2100B001

Pressure cap for valves DN10 VA2202A010

Pressure cap for valves DN15 VA2202A015

Pressure cap for valves DN20 VA2202A020

Seal for pressure cap, for valves DN10 VA5090A010

Seal for pressure cap, for valves DN15 VA5090A015

Seal for pressure cap, for valves DN20 VA5090A020

Service tool for exchanging valve insert during operation VA8200A001

Precision pre-setting tool for Mira-3 VA8201M301

Mira-3 valve insert VS1200M301

Mira-3 handwheel VS4200MI03

Page 311: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-38

Manual Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Manual radiator valve, convertible to thermostatic operationFor water-based one- and two-pipe heating systems.

Accessories

Manual radiator valve, convertible to thermostatic operation.For water-based heating systems.

Optimal-plus (V2652) Manual radiator valve

Materials Valve housing made of nickel-plated red bronze. Valve insert made of brass with EPDM O-rings. Handwheel made of white plastic. Threaded tailpiece and connection nut made of nickel-plated brass

Place in installation supply

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 90 oC

Pressure rating PN10

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Pre-setting no

Body pattern DN size Kvs value Connection diameter Threads type Typemm inch

angle 10 2,1 R 3/8 – V2652E0010angle 15 2,3 R 1/2 NPT V2652E0015angle 20 2,7 R 3/4 – V2652E0020

straight 10 1,7 R 3/8 – V2652D0010straight 15 1,8 R 1/2 – V2652D0015straight 20 2,2 R 3/4 – V2652D0020

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Service tool for exchange of valve insert during operation VA8200A001

MARS Series Premium Manual Valve (V300)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of grey plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Page 312: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-39

Manual Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Ordering Information

Service parts

Manual radiator valve, convertible to thermostatic operation.For water-based heating systems.

Ordering Information

Service parts

Body pattern DN size Kvs value Connection diameter Typemm inch

angle 10 1,62 3/8 V300EBB10angle 15 1,62 1/2 V300EBB15

straight 10 1,47 3/8 V300DBB10straight 15 1,47 1/2 V300DBB15

Replacement valve insert VS1200BB01

Replacement handwheel (10 pcs) H100-1/2D

Pressure cap for valves DN10 VA2202A010

Pressure cap for valves DN15 VA2202A015

Sealing for pressure cap VA2202A010 VA5090A010

Sealing for pressure cap VA2202A015 VA5090A015

Service tool VA8200A001

VENUS Series Premium Manual Valve (V310)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of grey plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Kvs value 0,59

Body pattern DN size Connection diameter Typemm inch

angle 10 3/8 V310EBB10angle 15 1/2 V310EBB15

straight 10 3/8 V310DBB10straight 15 1/2 V310DBB15

horizontal angle 15 1/2 V310RBB15

Replacement valve insert VS1200BB01

Replacement handwheel (10 pcs) H100-1/2D

Pressure cap for valves DN10 VA2202A010

Pressure cap for valves DN15 VA2202A015

Sealing for pressure cap VA2202A010 VA5090A010

Sealing for pressure cap VA2202A015 VA5090A015

Service tool VA8200A001

Page 313: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-40

Lockshield Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Lockshield Valves

The new Honeywell Design Line is particularly styled for use with design radiators. With their high class appearance they perfectly fit to all kinds of ambients.

• Verafix Design lockshield valves are used to connect radiators and other heat exchangers to heating circuits of hydronic heating systems. They are installed at the return port of the radiator and offer a shutoff function to separate the radiator from the heating circuit, for example for renovating.

For water-based heating systems.

Design white

Design chrome

Thera Design Edition - Lockshield Valve

Materials Valve housing made of brass with chrome or white (RAL 9016) surface; Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle; Protection cap made of brass with chrome or white (RAL 9016) surface; Union-nut and tailpiece made of chrome plated brass with EPDM O-ring

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Place in installation return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Design yes

DN size 15 mm

Port connection external threads

Heat exchanger connection 1/2 inch

Body pattern Colour Typeangle white V2481E0015

straight white V2481D0015double angle right white V2481R0015

double angle left white V2481L0015

Body pattern Colour Typeangle chrome V2482E0015

straight chrome V2482D0015double angle right chrome V2482R0015

double angle left chrome V2482L0015

Page 314: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-41

Lockshield Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Valve Accessories

Accessories - Pipe Connections

Rosette white (RAL9016) for wall covering; 40 x 12mm VA2201D012

Rosette white (RAL9016) for wall covering; 40 x 14mm VA2201D014

Rosette white (RAL9016) for wall covering; 40 x 15mm VA2201D015

Rosette white (RAL9016) for wall covering; 40 x 16mm VA2201D016

Rosette white (RAL9016) for wall covering; 40 x 18mm VA2201D018

Rosette white (RAL9016) for wall covering; 40 x 20mm VA2201D020

Rosette chrome for wall covering; 40 x 12mm VA2201E012

Rosette chrome for wall covering; 40 x 14mm VA2201E014

Rosette chrome for wall covering; 40 x 15mm VA2201E015

Rosette chrome for wall covering; 40 x 16mm VA2201E016

Rosette chrome for wall covering; 40 x 18mm VA2201E018

Rosette chrome for wall covering; 40 x 20mm VA2201E020

Connection for copper pipe (1 pcs.); 24 x 19 x 12mm VA720C1200

Connection for copper pipe (1 pcs.); 24 x 19 x 14mm VA720C1400

Connection for copper pipe (1 pcs.); 24 x 19 x 15mm VA720C1500

Connection for copper pipe (1 pcs.); 24 x 19 x 16mm VA720C1600

Connection for PE-X pipe (1 pcs.); 24 x 19 x 12 x 1,1mm VA721C1211

Connection for PE-X pipe (1 pcs.); 24 x 19 x 14 x 2mm VA721C1420

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 1,5mm VA721C1615

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 2mm VA721C1620

Connection for PE-X pipe (1 pcs.); 24 x 19 x 18 x 2mm VA721C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 14 x 2mm VA722C1420

Connection for multilayer pipe (1 pcs.); 24 x 19 x 16 x 2mm VA722C1620

Connection for multilayer pipe (1 pcs.); 24 x 19 x 18 x 2mm VA722C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 20 x 2mm VA722C2020

Page 315: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-42

Lockshield Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pre-settable radiator lockshield valve for the return with shut-off facility. Optional flow direction. Supports draining and filling. Reproducible pre-setting is not affected by draining process. O-ring spindle sealsFor water-based heating systems.

Verafix with nickel-plated tailpiece

Verafix with external threads

Accessories

Service parts

Verafix (V2400) radiator lockshield valve

Materials Valve body made of nickel-plated red bronze. Valve insert made of brass with EPDM O-rings. Tailpiece, protection cap and union-nut made of nickelplated brass.

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Measuring support no

Place in installation return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Additional description • Installation in supply also possible, draining/filling function isn't supported!

• Suitable connections see 'Connections for Radiator Valves'.

Body pattern DN size Kvs value Connection diameter Port connection Typemm inch

angle to DIN 10 1,7 3/8 internal threads V2400E0010angle to DIN 15 1,7 1/2 internal threads V2400E0015angle to DIN 20 1,7 3/4 internal threads V2400E0020

straight to DIN 10 1,4 3/8 internal threads V2400D0010straight to DIN 15 1,45 1/2 internal threads V2400D0015straight to DIN 20 1,5 3/4 internal threads V2400D0020

Body pattern DN size Kvs value Connection diameter Port connection Typemm inch

straight 15 1,45 3/4 external threads V2406D0015

Draining adapter for all sizes VA3300A001

Special Verafix tool VA8300A001

Cover cap for all sizes VS3301A001

Sealing ring for cover cap VS3302A001

Valve insert VS1300VF02

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Page 316: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-43

Lockshield Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Pre-settable radiator lockshield valve for the return with shut-off facility. Optional flow direction. Supports draining and filling. O-ring spindle seals.For water-based heating systems.

Verafix-E with nickel-plated tailpiece

Verafix-E with external threads

Accessories

Spare parts

Verafix-E (V2420) radiator lockshield valve

Materials Valve housing made of nickel-plated red bronze. Valve insert made of brass with EPDM seals. Tailpiece, protection cap and union-nut made of nickel-plated brass

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Measuring support no

Place in installation return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Additional description • Installation in supply also possible, draining/filling function isn't supported!

• Suitable connections see 'Connections for Radiator Valves'.

Body pattern DN size Kvs value Connection diameter Port connection Typemm inch

angle to DIN 10 1,7 3/8 internal threads V2420E0010angle to DIN 15 1,7 1/2 internal threads V2420E0015angle to DIN 20 1,7 3/4 internal threads V2420E0020

straight to DIN 10 1,4 3/8 internal threads V2420D0010straight to DIN 15 1,45 1/2 internal threads V2420D0015straight to DIN 20 1,5 3/4 internal threads V2420D0020

Body pattern DN size Kvs value Connection diameter Port connection Typemm inch

straight 15 1,45 3/4 external threads V2426D0015

Draining adapter for all sizes VA3300A001

Special Verafix tool VA8300A001

Nickel-plated cover cap for all sizes VS3301C001

Sealing ring for cover cap VS3302A001

Valve insert VS1300VF02

Pressure cap, for valves DN10 VA2202A010

Pressure cap, for valves DN15 VA2202A015

Pressure cap, for valves DN20 VA2202A020

Sealing ring for pressure cap, for valves DN10 VA5090A010

Sealing ring for pressure cap, for valves DN15 VA5090A015

Sealing ring for pressure cap, for valves DN20 VA5090A020

Page 317: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-44

Lockshield Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Radiator lockshield valve for the return with shut-off facility.For water-based heating systems.

Ordering Information

Radiator lockshield valve for the return with shut-off facility.For water-based heating systems.

Ordering Information

MARS Series Lockshield Valve (V330)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of grey plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring

Shut-off facility yes

Place in installation return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Body pattern DN size Connection diameter Typemm inch

angle 10 3/8 V330E010angle 15 1/2 V330E015

straight 10 3/8 V330D010straight 15 1/2 V330D015

VENUS Series Lockshield Valve (V340)

Materials Valve housing made of nickel-plated brass. Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle. Protection cap made of grey plastic. Union-nut and tailpiece made of nickel plated brass with EPDM O-ring

Shut-off facility yes

Place in installation return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 120 oC

Pressure rating PN10

Body pattern DN size Connection diameter Typemm inch

angle 10 3/8 V340E010angle 15 1/2 V340E015

straight 10 3/8 V340D010straight 15 1/2 V340D015

Page 318: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-45

Valves for Compact Radiators

2

3

4

5

6

7

8

10

9

11

12

13

14

Valves for Compact Radiators

The new Honeywell Design Line is particularly styled for use with design radiators. With their high class appearance they perfectly fit to all kinds of ambients.

• The Therafix Design is used to connect design radiators with 50mm connection distance to two-pipe hydronic heating systems. Therafix Design is equipped with a pre-settable TRV insert in the supply, a pre-settable lockshield insert in the return and an M30 x 1.5 thermostat thread.

For water-based heating systems.

Design white

Design chrome

Valve Accessories

Therafix Design - H-Block with TRV Insert

Materials Valve housing made of brass with chrome or white (RAL 9016) surface; Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle; Protection cap made of plastic; Union-nut and tailpiece made of chrome plated brass with EPDM O-ring

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Place in installation supply

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

DN size 15 mm

Port connection external threads

Heat exchanger connection 1/2 inch

Body pattern Typeangle right V2881RSL15angle left V2881LSL15straight V2881DSL15

Body pattern Typeangle right V2882RSL15angle left V2882LSL15straight V2882DSL15

Manual design handwheel, white (RAL9016) VA2200C001

Manual design handwheel, chrome VA2200C002

Rosette white (RAL9016) for wall covering; 40 x 12mm VA2201D012

Rosette white (RAL9016) for wall covering; 40 x 14mm VA2201D014

Rosette white (RAL9016) for wall covering; 40 x 15mm VA2201D015

Rosette white (RAL9016) for wall covering; 40 x 16mm VA2201D016

Rosette white (RAL9016) for wall covering; 40 x 18mm VA2201D018

Rosette white (RAL9016) for wall covering; 40 x 20mm VA2201D020

Rosette chrome for wall covering; 40 x 12mm VA2201E012

Rosette chrome for wall covering; 40 x 14mm VA2201E014

Rosette chrome for wall covering; 40 x 15mm VA2201E015

Rosette chrome for wall covering; 40 x 16mm VA2201E016

Rosette chrome for wall covering; 40 x 18mm VA2201E018

Rosette chrome for wall covering; 40 x 20mm VA2201E020

Page 319: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-46

Valves for Compact Radiators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Accessories - Pipe Connections

Service parts

Low-noise thermostatic compact radiator valve insert with pre-settable stroke limitation. S type with additional sleeve and seat sealing.For water-based heating systems as valve insert for compact radiators or six-point radiators.

Connection for copper pipe (1 pcs.); 24 x 19 x 12mm VA720C1200

Connection for copper pipe (1 pcs.); 24 x 19 x 14mm VA720C1400

Connection for copper pipe (1 pcs.); 24 x 19 x 15mm VA720C1500

Connection for copper pipe (1 pcs.); 24 x 19 x 16mm VA720C1600

Connection for PE-X pipe (1 pcs.); 24 x 19 x 12 x 1,1mm VA721C1211

Connection for PE-X pipe (1 pcs.); 24 x 19 x 14 x 2mm VA721C1420

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 1,5mm VA721C1615

Connection for PE-X pipe (1 pcs.); 24 x 19 x 16 x 2mm VA721C1620

Connection for PE-X pipe (1 pcs.); 24 x 19 x 18 x 2mm VA721C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 14 x 2mm VA722C1420

Connection for multilayer pipe (1 pcs.); 24 x 19 x 16 x 2mm VA722C1620

Connection for multilayer pipe (1 pcs.); 24 x 19 x 18 x 2mm VA722C1820

Connection for multilayer pipe (1 pcs.); 24 x 19 x 20 x 2mm VA722C2020

Valve insert VS1200SLGB01

Service tool to replace valve insert VA8200A001

Valve Inserts (V200N, V200S)

Materials Brass with EPDM O-rings and seat sealing, spindle made of stainless steel.

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 1 bar

Closing dimension 11,5 mm

Stroke 2,5 mm

Body-head connection M30 x 1,5

Pre-settable by stroke limitation

Colour of protection cap white

Heat exchanger connection 1/2 inch

Kvs value Type1,5 V200NCUB151,1 V200SCUB15

Page 320: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-47

Valves for Compact Radiators

2

3

4

5

6

7

8

10

9

11

12

13

14

Pre-settable H-block for compact and six-point radiators. With pre-setting, shut-off facility and draining support. Suitable for radiators with 3/4" external or 1/2" internal thread connections.For water-based heating systems.

Verafix-VK for two-pipe systems

Verafix-VK for one- and two-pipe systems

Accessories

Verafix-VK (V2461, V2471) connection block for compact and six-point radiators

Materials Valve housing made of matt nickel-plated hot-forged brass, valve insert made of brass with EPDM or NBR O-ring sealings and brass union connections.

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Measuring support no

Place in installation supply and return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 110 oC

Pressure rating PN10

Supply/return port distance 50 mm

DN size 15 mm

Connection diameter 3/4 inch

Port connection external threads

Additional description Please note:• kvs-values one-pipe version refer to 50% radiator proportion valve

insert with kv=0,87.• Suitable connections see 'Connections for Radiator Valves' for

suitable pipe connections.

Body pattern Kvs value Heat exchanger connection Typeinch

angle 1,5 G3/4A V2471EX20angle 1,5 G1/2 V2471EY15

straight 1,5 G3/4A V2471DX20straight 1,5 G1/2 V2471DY15

Body pattern Kvs value Heat exchanger connection Typeinch

angle 1,23 G3/4A V2461EX20angle 1,23 G1/2 V2461EY15

straight 1,15 G3/4A V2461DX20straight 1,15 G1/2 V2461DY15

Draining adapter for Verafix-VK and -VKE VA3300B001

Page 321: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-48

Valves for Compact Radiators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Pre-settable H-block for compact and six-point radiators. With shut-off facility. Suitable for radiators with 3/4" external or 1/2" internal thread connections.For water-based heating systems.

Verafix-VKE (V2476) connection block for compact and six-point radiators

Materials Valve housing made of matt nickel-plated hot-forged brass, valve insert made of brass with EPDM or NBR O-ring sealings and brass union connections.

Shut-off facility yes

Pre-setting yes

Draining/filling support no

Measuring support no

Place in installation supply and return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 110 oC

Pressure rating PN10

Supply/return port distance 50 mm

DN size 15 mm

Kvs value 1,5

Connection diameter 3/4 inch

Port connection external threads

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern Heat exchanger connection Typeinch

angle G3/4A V2476EX020angle G1/2 V2476EY015

straight G3/4A V2476DX020straight G1/2 V2476DY015

Page 322: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-49

Valves for Compact Radiators

2

3

4

5

6

7

8

10

9

11

12

13

14

Pre-settable radiator lockshield valve for compact and six-point radiators. With shut-off facility and draining support. Suitable for radiators with 3/4" external or 1/2" internal thread connections.For water-based heating systems.

Verafix-EK with external thread pipe connection

Verafix-EK with internal thread pipe connection

Accessories

Verafix-EK (V2465, V2466) radiator lockshield valves with special connections for compact and six-point radiators

Materials Valve housing made of matt nickel-plated red bronze, valve insert made of brass with EPDM or NBR O-ring sealings and brass union connections.

Shut-off facility yes

Pre-setting yes

Draining/filling support yes

Measuring support no

Place in installation supply and return

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

DN size 15 mm

Additional description Two Verafix-EK are required to connect a radiator.

Body pattern Kvs value Connection diameter Port connection Heat exchanger connection Typeinch inch

angle 1,7 3/4 external threads G1/2 V2465EX015angle 1,7 3/4 external threads G3/4A V2465EY015

straight 1,45 3/4 external threads G1/2 V2465DX015straight 1,45 3/4 external threads G3/4A V2465DY015

Body pattern Kvs value Connection diameter Port connection Heat exchanger connection Typeinch inch

angle 1,7 1/2 internal threads G1/2 V2466EX015angle 1,7 1/2 internal threads G3/4A V2420E0015

straight 1,45 1/2 internal threads G1/2 V2466DX015straight 1,45 1/2 internal threads G3/4A V2420D0015

Draining adapter VA3300A001

Special Verafix tool VA8300A001

Page 323: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-50

Valves for Compact Radiators

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The Verafix-VKE is an lockshield valve for compact radiators with connection centres of 50 mm. It is used on two-pipe systems with radiators which have integral valves to regulate and shut-off individual radiators. For water-based heating systems.

Ordering Information

Accessories

Verafix-VKE H-Block for Compact and 6-point Radiators (V2495)

Materials Valve housing made of hot-forged brass, valve insert made of brass with EPDM or PTFE sealings.

Shut-off facility yes

Place in installation supply and return

Medium type water

Media temp. 2 ... 120 oC

Pressure rating PN10

Supply/return port distance 50 mm

DN size 15 mm

Connection diameter 3/4 inch

Additional description Suitable connections see 'Connections for Radiator Valves'.

Body pattern Kvs value Port connection Heat exchanger connection Typeinch

angle 1,8 external threads G3/4A V2495EX020Aangle 1,8 internal threads G1/2 V2495EY015A

straight 3,5 external threads G3/4A V2495DX020straight 3,5 internal threads G1/2 V2495DY015

Double nipple (2 pcs) VS3295A015

Connections for copper and soft steel pipe (2 pcs); 3/4" x 10 mm VA7200A010

Connections for copper and soft steel pipe (2 pcs); 3/4" x 12 mm VA7200A012

Connections for copper and soft steel pipe (2 pcs); 3/4" x 14 mm VA7200A014

Connections for copper and soft steel pipe (2 pcs); 3/4" x 15 mm VA7200A015

Connections for copper and soft steel pipe (2 pcs); 3/4" x 16 mm VA7200A016

Connections for copper and soft steel pipe (2 pcs); 3/4" x 18 mm VA7200A018

Connection for PE-X pipe (2 pcs); 3/4" x 14 x 2 mm OT112M-3/4D

Connection for PE-X pipe (2 pcs); 3/4" x 16 x 2 mm OT112M-3/4F

Connection for PE-X pipe (2 pcs); 3/4" x 16 x 2.2 mm OT112M-3/4F2

Connection for PE-X pipe (2 pcs); 3/4" x 17 x 2 mm OT112M-3/4G

Connection for PE-X pipe (2 pcs); 3/4" x 18 x 2 mm OT112M-3/4H

Connection for composite pipe (2 pcs); 3/4" x 14 x 2 mm OT113M-3/4D

Connection for composite pipe (2 pcs); 3/4" x 16 x 2 mm OT113M-3/4F

Connection for composite pipe (2 pcs); 3/4" x 18 x 2 mm OT113M-3/4H

Connection for copper pipe (2 pcs); 3/4" x 10 mm OT114M-3/4B

Connection for copper pipe (2 pcs); 3/4" x 12 mm OT114M-3/4C

Connection for copper pipe (2 pcs); 3/4" x 14 mm OT114M-3/4D

Connection for copper pipe (2 pcs); 3/4" x 15 mm OT114M-3/4E

Connection for copper pipe (2 pcs); 3/4" x 16 mm OT114M-3/4F

Connection for copper pipe (2 pcs); 3/4" x 18 mm OT114M-3/4H

Page 324: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-51

Valves for Compact Radiators

2

3

4

5

6

7

8

10

9

11

12

13

14

The Verafix-VKE is an lockshield valve for compact radiators with connection centres of 50 mm. It is used on two-pipe systems with radiators which have integral valves to regulate and shut-off individual radiators. For water-based heating systems.

Ordering Information

Accessories

Verafix-VKE H-Block for Compact (V2496)

Materials Valve housing made of hot-forged brass, valve insert made of brass with EPDM or PTFE sealings.

Shut-off facility yes

Place in installation supply and return

Medium type water

Media temp. 2 ... 120 oC

Pressure rating PN10

Supply/return port distance 50 mm

DN size 15 mm

Connection diameter 3/4 inch

Port connection external threads

Additional description • Optional flow direction. Performance values apply for both directions of flow

• Robust brass housing• Connection on pipework side 3/4" external thread for copper, soft

steel, plastic and composite pipes• Connectors on radiator side 1/2" internal or 3/4" external thread

Body pattern Kvs value Heat exchanger connection (inch) Typeangle 1,8 G3/4A V2496EX020Aangle 1,8 G1/2 V2496EY015A

straight 3,5 G3/4A V2496DX020straight 3,5 G1/2 V2496DY015

Double nipple (2 pcs) VS3296A015

Flat seal VA5096A015

Flat seal and cone (2 pcs) VA5096B015

Connections for copper and soft steel pipe (2 pcs); 3/4" x 10 mm VA7200A010

Connections for copper and soft steel pipe (2 pcs); 3/4" x 12 mm VA7200A012

Connections for copper and soft steel pipe (2 pcs); 3/4" x 14 mm VA7200A014

Connections for copper and soft steel pipe (2 pcs); 3/4" x 15 mm VA7200A015

Connections for copper and soft steel pipe (2 pcs); 3/4" x 16 mm VA7200A016

Connections for copper and soft steel pipe (2 pcs); 3/4" x 18 mm VA7200A018

Connection for PE-X pipe (2 pcs); 3/4" x 14 x 2 mm OT112M-3/4D

Connection for PE-X pipe (2 pcs); 3/4" x 16 x 2 mm OT112M-3/4F

Connection for PE-X pipe (2 pcs); 3/4" x 16 x 2.2 mm OT112M-3/4F2

Connection for PE-X pipe (2 pcs); 3/4" x 17 x 2 mm OT112M-3/4G

Connection for PE-X pipe (2 pcs); 3/4" x 18 x 2 mm OT112M-3/4H

Connection for composite pipe (2 pcs); 3/4" x 14 x 2 mm OT113M-3/4D

Connection for composite pipe (2 pcs); 3/4" x 16 x 2 mm OT113M-3/4F

Connection for composite pipe (2 pcs); 3/4" x 18 x 2 mm OT113M-3/4H

Connection for copper pipe (2 pcs); 3/4" x 10 mm OT114M-3/4B

Connection for copper pipe (2 pcs); 3/4" x 12 mm OT114M-3/4C

Connection for copper pipe (2 pcs); 3/4" x 14 mm OT114M-3/4D

Connection for copper pipe (2 pcs); 3/4" x 15 mm OT114M-3/4E

Connection for copper pipe (2 pcs); 3/4" x 16 mm OT114M-3/4F

Connection for copper pipe (2 pcs); 3/4" x 18 mm OT114M-3/4H

Page 325: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

13-52

Connections for Radiator Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Connections for Radiator Valves

Connection to connect plastic pipe to valves with 3/4" external thread and euroconeFor hydronic heating and cooling systems

OT112M Connection for plastic pipe

Product description Type3/4" x 14 x 2mm (for 14 x 2mm Pe-X pipe), pack of 2 pcs OT112M-3/4D3/4" x 16 x 2mm (for 16 x 2mm Pe-X pipe), pack of 2 pcs OT112M-3/4F3/4" x 16 x 2.2mm (for 16 x 2.2mm Pe-X pipe), pack of 2 pcs OT112M-3/4F23/4" x 17 x 2mm (for 17 x 2mm Pe-X pipe), pack of 2 pcs OT112M-3/4G3/4" x 18 x 2mm (for 18 x 2mm Pe-X pipe), pack of 2 pcs OT112M-3/4H

Page 326: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

2

3

4

5

6

7

8

10

9

11

12

13

14

Balancing and Pipeline Valves Page

Balancing Valves 14-2Other Pipework Valves 14-17

Page 327: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-2

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Balancing Valves

The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It is installed in either supply or return pipeline. When installed in supply it can also be used to connect impulse tube of a V5001P Kombi-Auto differential pressure control valve.

• Rugged, robust design• High flowrates• Insulation shells included• Supports flow measurement with Honeywell SafeConTM quick connections• Two measuring ranges, one for standard flow, one for low flow conditions

With internal threads to ISO 7 (DIN 2999)

V5001S Kombi-S Shutoff Valve

Materials Valve housing made of red bronze, spindle made of brass with EPDM O-rings and seat sealing, handwheel made of red plastic

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. -20 ... 130 oC

Pressure rating PN16

Connection of accessories

side connections

Place in installation supply

Port connection internal threads

Type of Control static pressure

More Information http://www.hydronic-balancing.info/home-en.html

DN size Kvs value Port diameter Typemm inch

15 4,7 Rp 1/2 V5001SY201520 8,1 Rp 3/4 V5001SY202025 10,7 Rp 1 V5001SY202532 23,3 Rp 1 1/4 V5001SY203240 35,3 Rp 1 1/2 V5001SY204050 48,8 Rp 2 V5001SY2050

Page 328: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-3

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

VM242A BasicMes-2 handheld measuring computer

For all sizes. Computer is supplied with case and accessories VM242A0101

Spare set of 2 pressure test valves G1/4" VS2600C001

Shutoff valve for impulse tube VS5501A008

Draining valve VA3401A008

Replacement inserts for DN15 V5001SZ1015

Replacement inserts for DN20 V5001SZ1020

Replacement inserts for DN25 V5001SZ1025

Replacement inserts for DN32 V5001SZ1032

Replacement inserts for DN40 V5001SZ1040

Replacement inserts for DN50 V5001SZ1050

Insulation shells for DN15 VA2510D015

Insulation shells for DN20 VA2510D020

Insulation shells for DN25 VA2510D025

Insulation shells for DN32 VA2510D032

Insulation shells for DN40 VA2510D040

Insulation shells for DN50 VA2510D050

Page 329: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-4

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The V5001P Kombi-Auto differential pressure control valve is used to maintain a hydronic balance in residential or commercial hydronic heating and cooling systems. It is installed in the return pipeline. It is used in systems with variable volume flows, for example two-pipe heating systems, and creates a hydronic balance by keeping differential pressure over consumers at a constant preset level even under changing flow conditions, for example in part load states. Hydronic balance is a significant requirement for efficient operation of a hydronic heating or cooling system. In an unbalanced system under- or oversupply of energy to individual circuits or heat exchangers can occur. Apart from correct selection of radiator valves, regulation of individual circuits is necessary and in some countries required by national standards or regulations. Apart from pressure control the Kombi-Auto also provides shutoff function. Pressure sensing in supply is done by a Kombi-S stop valve. Compact body design allows installation under restricted space conditions.

• Rugged, robust design• High flowrates• Insulation shells included• Wide presetting range for easy selection• Easy presetting with stepless delta p-scale and without the need of tools• Easy, lockable presetting with external handwheel• Supports flow measurement with Honeywell SafeConTM quick connections

Differential pressure presetting range 5..35 kPa

V5001P Kombi-Auto Differential Pressure Control Valve

Materials Valve housing made of red bronze, valve insert made of brass with EPDM O-rings and seat sealing, handwheel made of blue plastic

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. -20 ... 130 oC

Pressure rating PN16

Pre-setting yes

Position indication Digital display of pre-setting value.

Automatic balancing support

yes

Connection of accessories

side connections

Place in installation return

Port connection internal threads

Type of Control differential pressure

More Information http://www.hydronic-balancing.info/home-en.html

DN size Kvs value Port diameter Minimum flow (qi) Maximum flow (qs) Delta-P Typemm inch l/h l/h kPa

15 3,6 Rp 1/2 40 1700 5 ... 35 V5001PY101520 5,8 Rp 3/4 60 2600 5 ... 35 V5001PY102025 7,1 Rp 1 100 3000 5 ... 35 V5001PY102532 15,4 Rp 1 1/4 150 6500 5 ... 35 V5001PY103240 22 Rp 1 1/2 200 9000 5 ... 35 V5001PY104050 35,8 Rp 2 450 19000 5 ... 35 V5001PY1050

Page 330: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-5

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Differential pressure presetting range 30..60 kPa

DN size Kvs value Port diameter Minimum flow (qi) Maximum flow (qs) Delta-P Typemm inch l/h l/h kPa

15 3,6 Rp 1/2 50 1900 30 ... 60 V5001PY201520 5,8 Rp 3/4 50 3000 30 ... 60 V5001PY202025 7,1 Rp 1 100 3500 30 ... 60 V5001PY202532 15,4 Rp 1 1/4 200 10000 30 ... 60 V5001PY203240 22 Rp 1 1/2 250 13000 30 ... 60 V5001PY204050 35,8 Rp 2 500 20000 30 ... 60 V5001PY2050

VM242A BasicMes-2 handheld measuring computer VM242A0101

V5001S Kombi-S shutoff valve DN15 V5001SY2015

V5001S Kombi-S shutoff valve DN20 V5001SY2020

V5001S Kombi-S shutoff valve DN25 V5001SY2025

V5001S Kombi-S shutoff valve DN32 V5001SY2032

V5001S Kombi-S shutoff valve DN40 V5001SY2040

V5001S Kombi-S shutoff valve DN50 V5001SY2050

Spare set of 2 pressure test cocks G1/4" VS2600C001

Shutoff valve for impulse tube VS5501A008

Draining valve VA3401A008

Replacement inserts, 5...35 kPa, for DN15 V5001PZ1015

Replacement inserts, 5...35 kPa, for DN20 V5001PZ1020

Replacement inserts, 5...35 kPa, for DN25 V5001PZ1025

Replacement inserts, 5...35 kPa, for DN32 V5001PZ1032

Replacement inserts, 5...35 kPa, for DN40 V5001PZ1040

Replacement inserts, 5...35 kPa, for DN50 V5001PZ1050

Replacement impulse tube VA2500CU04

Compression fittings for impulse tube for copper pipe 4 x 1mm VS5500A004

Insulation shells for DN15 VA2510D015

Insulation shells for DN20 VA2510D020

Insulation shells for DN25 VA2510D025

Insulation shells for DN32 VA2510D032

Insulation shells for DN40 VA2510D040

Insulation shells for DN50 VA2510D050

Page 331: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-6

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The V5003F Kombi-VX is an automatic balancing valve. It is designed for balancing of heating and cooling systems by providing a constant flow rate even under changing pressure conditions. The flow rate can be externally adjusted via pre-settings.For water-based heating and cooling systems.

V5003F Kombi-VX Pre-settable Flow Control Valve

Materials Valve housing made of brass CuZn40Pb2; valve insert made of brass, stainless steel and plastic with rubber diaphragm and EPDM o-rings

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. -20 ... 120 oC

Pressure rating PN25

Pre-setting yes

Position indication Digital display of pre-setting value.

Measuring support yes

Automatic balancing support

yes

Place in installation supply or return

Port connection internal threads

Additional description • Compact design of both valve housing and valve insert• Various versions for different flow ranges and differential

pressure ranges available• Valve inserts with clear digital display of pre-setting value• Valve insert in cartridge design, easily removable for flushing,

easily exchangeable• Simplified measuring with Honeywell SafeConTM pressure test

connections• Pressure measuring ports on same side as presetting• Robust against dirt, residue, deposit and critical medium• Maintenance free design

Type of Control flow

More Information http://www.hydronic-balancing.info/home-en.html

Page 332: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-7

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Accessories

Spare parts

DN size Minimum flow (qi) Maximum flow (qs) Delta-P Typemm l/h l/h kPa

15 100 412 17 ... 210 V5003FY1015041215 157 609 17 ... 210 V5003FY1015060915 276 825 17 ... 200 V5003FY1015082515 138 615 35 ... 400 V5003FY2015061515 238 896 35 ... 400 V5003FY2015089615 406 1270 35 ... 400 V5003FY2015127020 100 412 17 ... 210 V5003FY1020041220 157 609 17 ... 210 V5003FY1020060920 276 825 17 ... 200 V5003FY1020082520 138 615 35 ... 400 V5003FY2020061520 238 896 35 ... 400 V5003FY2020089620 406 1270 35 ... 400 V5003FY2020127025 100 412 17 ... 210 V5003FY1025041225 157 609 17 ... 210 V5003FY1025060925 276 825 17 ... 200 V5003FY1025082525 138 615 35 ... 400 V5003FY2025061525 238 896 35 ... 400 V5003FY2025089625 406 1270 35 ... 400 V5003FY2025127025 535 5830 17 ... 400 V5003FY1026502032 535 5830 17 ... 400 V5003FY1032502040 3180 16100 20 ... 400 V5003FY1040161050 3180 16100 20 ... 400 V5003FY10501610

Pre-setting key VA5003ZA001

Brass blind cap for valve size DN15...25 VA5003ZA003

Brass blind cap for valve size DN25 (LI)...32 VA5003ZA004

Brass blind cap for valve size DN40...50 VA5003ZA005

Measuring adapter (2pcs.) VA3600C001

Extension piece for pressure test cocks, length 45 mm, for insulated valves VA2601A008

BasicMes-2 Handheld flow measuring computer VM242A0101

Valve insert DN15...25; flow range 100...412 l/h; delta-P 17...210 kPa V5003FZ10150412

Valve insert DN15...25; flow range 157...609 l/h; delta-P 17...210 kPa V5003FZ10150609

Valve insert DN15...25; flow range 276...825 l/h; delta-P 17...200 kPa V5003FZ10150825

Valve insert DN15...25; flow range 138...615 l/h; delta-P 35...400 kPa V5003FZ20150615

Valve insert DN15...25; flow range 238...896 l/h; delta-P 35...4000 kPa V5003FZ20150896

Valve insert DN15...25; flow range 406...1270 l/h; delta-P 30...4000 kPa V5003FZ20151270

Valve insert DN25 (LI)...32; flow range 535...5830 l/h; delta-P 17...400 kPa V5003FZ10325020

Valve insert DN40...50; flow range 3180...16100 l/h; delta-P 20...400 kPa V5003FZ10501610

Page 333: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-8

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The V5003T Kombi-QM is a pressure-independent two-way flow control valve for modulating control. Each valve has a pre-settable maximum flowrate setting to allow flow limitation and balancing of the controlled system. Equiped with an actuator Kombi-QM provides a full stroke modulating control. Kombi-QM is designed as a 2-in-1 solution combining a modulating control valve with an automatic balancing valve which is differential pressure independent. V5003T Kombi-QM is typically used for balancing and temper-ature control of fan coil units, air handling units, chilled ceilings and one-pipe heating systems.For water-based heating and cooling systems.

V5003T Kombi-QM Pre-settable Pressure Independant Control Valve

Materials Valve housing made of brass CuZn40Pb2; valve insert made of brass, stainless steel and plastic with rubber diaphragm and EPDM o-rings

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. -20 ... 120 oC

Pressure rating PN25

Pre-setting yes

Position indication Digital display of pre-setting value.

Measuring support yes

Automatic balancing support

yes

Place in installation supply or return

Port connection internal threads

Additional description • Compact design of both valve housing and valve insert• Full stroke control • 100% valve authority• Two ranges available for high and low flow• Valve inserts with clear digital display of pre-setting value• Valve insert in cartridge design, easily removable for flushing,

easily exchangeable• Simplified measuring with Honeywell SafeConTM pressure test

connections• Pressure measuring ports on same side as presetting• Robust against dirt, residue, deposit and critical medium• Maintenance free design

Type of Control pressure independent

More Information http://www.hydronic-balancing.info/home-en.html

DN size Minimum flow (qi) Maximum flow (qs) Delta-P Typemm l/h l/h kPa

15 62 844 16 ... 200 V5003TY101520 62 844 16 ... 200 V5003TY102025 62 844 16 ... 200 V5003TY102515 119 1200 30 ... 400 V5003TY201520 119 1200 30 ... 400 V5003TY202025 119 1200 30 ... 400 V5003TY2025

Page 334: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-9

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Accessories

Spare parts

Pre-setting key VA5003ZA001

Brass blind cap for valve size DN15...25 VA5003ZA003

Actuator for modulating control; 24V power supply, suitable for 0...10V and 2...10V controller output signal

M7410E5001

Actuator for 3-point floating control; 24V power supply; 0,9m cable length M7410A1001

Actuator for 3-point floating control; 24V power supply, LON version M7410G1008

Thermoelectric actuator for on/off control; 24V and 230V power supply versions available. All MT4 versions usable with Kombi-QM

_MT4

Measuring adapter (2pcs.) VA3600C001

Extension piece for pressure test cocks, length 45 mm, for insulated valves VA2601A008

VM242A BasicMes-2 handheld measuring computer VM242A0101

Valve insert; flow range 62...844 l/h; delta-p 16...200 kPa V5003TZ1015

Valve insert; flow range 119...1200 l/h; delta-p 30...400 kPa V5003TZ2015

Page 335: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-10

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Shut-off valve with measuring support for supply mains and branches. To be used in combination with a V5010 Kombi-3-plus BLUE double-regulating balancing valve in the return.

• The hydronic balance is a significant requirement for the efficient operation of a hydronic heating or cooling installation. In an unbalanced system under or over provision of hot water to individual radiators or circuits can occur. Apart from the correct selection of radiator valves, regulation of individual circuits is also necessary and in some cases, such as in DIN 18 380, VOB part C, required by national standards. This requirement is met with Kombi-3-plus Series balancing valves.

• The V5000 Kombi-3-plus RED is a fixed orifice measuring valve for the supply with additional functions shutoff, draining and filling.

Water-based heating and cooling systems.

With internal threads to ISO 7 (DIN2999)

V5000 Kombi-3-plus RED Fixed Orifice Measuring Valve

Materials Valve housing made of red bronze, valve insert made of brass with EPDM O-rings and PTFE seat sealing, handwheel made of red plastic

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN16

Draining/filling support yes

Measuring support yes

Connection of accessories

through spindle

Place in installation supply

Additional description • Supports Honeywell measuring method: measuring and pre-setting of control valve simultaneously.

• Suitable connections see 'Connections for Balancing and Pipework Valves'.

Type of Control static pressure

More Information http://www.hydronic-balancing.info/home-en.html

DN size Kvs value Port connection Port diameter Typemm inch

10 1,5 internal threads Rp 3/8 V5000Y001015 2,5 internal threads Rp 1/2 V5000Y001520 4,5 internal threads Rp 3/4 V5000Y002025 6,5 internal threads Rp 1 V5000Y002532 13 internal threads Rp 1 1/4 V5000Y003240 20 internal threads Rp 1 1/2 V5000Y004050 35 internal threads Rp 2 V5000Y005065 42 internal threads Rp 2 1/2 V5000Y006580 68 internal threads Rp 3 V5000Y0080

Page 336: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-11

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

With external threads to DIN/ISO 228. Connection nuts and sealings are supplied with the valve

Accessories

DN size Kvs value Port connection Port diameter Typemm inch

10 1,5 external threads G 5/8 A V5000X001015 2,5 external threads G 3/4 A V5000X001520 4,5 external threads G 1 A V5000X002025 6,5 external threads G 1 1/4 A V5000X002532 13 external threads G 1 1/2 A V5000X003240 20 external threads G 1 3/4 A V5000X004050 35 external threads G 2 3/8 A V5000X0050

Insulation shells for valves DN10 and DN15 VA2510C015

Insulation shells for valves DN20 VA2510C020

Insulation shells for valves DN25 VA2510C025

Insulation shells for valves DN32 VA2510C032

Insulation shells for valves DN40 VA2510C040

Insulation shells for valves DN50 VA2510C050

Draining and filling adapter VA3500A001

Tamper-proof cap, for valves DN15...DN25 VA2501A010

Tamper-proof cap, for valves DN32...DN50 VA2501A032

VA3502A Pressure measuring set VA3502A001

VM242A BasicMes-2 handheld measuring computer VM242A0101

Page 337: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-12

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Double-regulating balancing valve for mains and branch pipelines. To be used in conjunction with a V5000 Kombi-3-plus RED valve in the supply.

• The hydronic balance is a significant requirement for the efficient operation of a hydronic heating or cooling installation. In an unbalanced system under or over provision of hot water to individual radiators or circuits can occur. Apart from the correct selection of radiator valves, regulation of individual circuits is also necessary and in some cases, such as in DIN 18 380, VOB part C, required by national standards. This requirement is met with Kombi-3-plus Series balancing valves.

• The V5010 Kombi-3-plus BLUE for the return is a double regulating balancing valve with additional functions shutoff, draining and filling. Together with a V5012 Kombi-DP diaphragm unit the Kombi-3-plus can be upgraded to an automatic balancing valve even after the system has been taken into commission and under system pressure.

For water-based heating and cooling systems.

With internal threads to ISO 7 (DIN2999)

V5010 Kombi-3-plus BLUE Double Regulating Balancing Valve

Materials Valve housing made of red bronze, valve insert made of brass with EPDM O-rings and PTFE seat sealing, handwheel made of blue plastic

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN16

Pre-setting yes

Position indication Digital display of pre-setting value.

Draining/filling support yes

Automatic balancing support

yes

Connection of accessories

through spindle

Place in installation return

Additional description • Can be converted into automatic Dp-Controller by retrofitting a V5012 Kombi-DP Diaphragm Unit (see 'Accessories'), also after installation has been put into service.

• Suitable connections see 'Connections for Balancing and Pipework Valves'.

Type of Control static pressure

More Information http://www.hydronic-balancing.info/home-en.html

DN size Kvs value Port connection Port diameter Typemm inch

10 2,4 internal threads Rp 3/8 V5010Y001015 2,7 internal threads Rp 1/2 V5010Y001520 6,4 internal threads Rp 3/4 V5010Y002025 6,8 internal threads Rp 1 V5010Y002532 21 internal threads Rp 1 1/4 V5010Y003240 22 internal threads Rp 1 1/2 V5010Y004050 38 internal threads Rp 2 V5010Y005065 47,7 internal threads Rp 2 1/2 V5010Y006580 71 internal threads Rp 3 V5010Y0080

Page 338: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-13

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

With external threads to DIN/ISO 228. Connection nuts and sealings are supplied with the valve

Accessories

The Honeywell M5003A actuator is specifically designed to provide floating or modulating control together with the Honeywell V5003T Kombi-QM.

• For use with Honeywell V5003TM5003A in combination with V5003T Kombi-QM is typically used for balancing and temperature control of fan coil units, chilled ceilings and one pipe heating systems.

DN size Kvs value Port connection Port diameter Typemm inch

10 2,4 external threads G 5/8 A V5010X001015 2,7 external threads G 3/4 A V5010X001520 6,4 external threads G 1 A V5010X002025 6,8 external threads G 1 1/4 A V5010X002532 21 external threads G 1 1/2 A V5010X003240 22 external threads G 1 3/4 A V5010X004050 38 external threads G 2 3/8 A V5010X0050

Adapter for actuator with M30 x 1,5 connection VA2500A001

Tamper-proof cap, for valves DN15...DN25 VA2501A010

Tamper-proof cap, for valves DN32...DN50 VA2501A032

Insulation shells for valves DN10 and DN15 VA2510C015

Insulation shells for valves DN20 VA2510C020

Insulation shells for valves DN25 VA2510C025

Insulation shells for valves DN32 VA2510C032

Insulation shells for valves DN40 VA2510C040

Insulation shells for valves DN50 VA2510C050

Draining and filling adapter VA3500A001

V5012C Kombi-Diaphragm Unit; Setting range 10...30 kPa(1.45...4.35 psi) differential pressure; for V5010 Kombi-3-plus BLUE DN10...DN40

V5012C0103

V5012C Kombi-Diaphragm Unit; Setting range 30...60 kPa (4.35...8.7 psi) differential pressure; for V5010 Kombi-3-plus BLUE DN10...DN40

V5012C0306

Linear Valve Actuator, 3-Point or Modulating (M5003A)

Materials Housing made of fireproof ABS casting

Stroke 4 mm

Connection size M30x1.5 mm

Power supply 24V AC 10%, 50/60 Hz

Max. media temperature 120 oC

Product description TypeControl signal analog 0(2)-10 V DC or 0(4)-20 mA M5003A1001Control signal 3-point M5003A1002

Page 339: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-14

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The V5012C Kombi-DP diaphragm unit is installed onto a V5010 Kombi-3-plus BLUE or V5032 Kombi-2-plus return mains balancing valve and connected to a V5000 Kombi-3-plus RED or V5100 Stop Valve-3 supply mains valve with the supplied impulse tube.

• It is used in systems with variable volume flows, for example two-pipe heating systems or district heating exchangers, and supports a hydronic balance by keeping the differential pressure over consumers at a constant pre-set level even under changing flow conditions.

• The V5012C Kombi-DP diaphragm unit can be fitted to the Kombi-Valves at any time, even when the system is under pressure and in operation operation of the system does not have to be interrupted to install the V5012C Kombi-DP.

For water-based heating and cooling systems.

Accessories

Service Parts

V5012C Kombi-DP Diaphragm Unit

Materials Membrane housing made of stainless steel with EPDM membrane, spindle and pipe connections made of brass

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN10

Max. delta P 2 bar

Pre-setting yes

Position indication V5012C0103 optionally with installed external setpoint adapter VA2503A001 (accessory).

Additional description Suitable for V5010 Kombi-3-plus BLUE DN10...40 and V5032 Kombi-2-plus DN15...40.

Differential pressure setpoint range TypekPa

10 ... 30 V5012C010330 ... 60 V5012C0306

Spring to reduce differential pressure pre-setting by 5 kPa(0,73 psi) VA2502A002

External pre-setting device for installation between Kombi-Diaphragm Unit and impulse tube, for V5012C0103 only (not with VA2504A001)

VA2503A001

Angle adapter VA2504A001

Compression fitting for 6 x 1 mm copper impulse tube VS5500A008

Shutoff fitting R 1/4 VS5501A008

Spindle assembly VS2500KDP1

Compression fitting for 4 x 1 mm copper impulse tube VS5500A004

Page 340: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-15

Balancing Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

VA2510C insulation shells are attached to suitable pipeline valves after valve installation and setup. They are suitable for Kombi and Alwa-type balancing and pipeline valves with small limitations - please see data sheet for details.

• Valves with internal threads are the V5000Y, V5010Y, V5020, V5032, V5040, V5100Y, V9010, VB550, VB551, VB560 and VB561.

• Valves with external threads are the V5000X, V5010X, V5015, V5016 and V5100XCompression ring and nut for valves with internal threads

2 compression rings, nuts and support inserts for valves with internal threads

VA2510C Pipeline Valves Insulation Shells

Materials EPP

Colour anthracite

Body pattern Y-pattern

Max. media temperature 100 oC

DN size Typemm

10/15 VA2510C01520 VA2510C02025 VA2510C02532 VA2510C03240 VA2510C04050 VA2510C050

Connections for Balancing and Pipework Valves

Product accessory Type3/8 x 10 mm VA650A10103/8 x 12 mm VA650A10121/2 x 10 mm VA650A15101/2 x 12 mm VA650A15121/2 x 14 mm VA650A15141/2 x 15 mm VA650A15151/2 x 16 mm VA650A15163/4 x 18 mm VA650A20183/4 x 22 mm VA650A2022

Product accessory Type3/8 x 12 mm VA651A10121/2 x 12 mm VA651A15121/2 x 15 mm VA651A15151/2 x 16 mm VA651A15163/4 x 18 mm VA651A2018

Page 341: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-16

Balancing Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Brass soldering connection for valves with external threads

Steel welding connection for valves with external threads

Externally threaded brass connection for valves with external threads

Sealing ring for valves with external threads (also supplied with valve)

Product accessory Type12 mm, for valves DN10 VA5530A01015 mm, for valves DN15 VA5530A01522 mm, for valves DN20 VA5530A02028 mm, for valves DN25 VA5530A02535 mm, for valves DN32 VA5530A03242 mm, for valves DN40 VA5530A04054 mm, for valves DN50 VA5530A050

Product accessory Typefor valves DN10 VA5540A010for valves DN15 VA5540A015for valves DN20 VA5540A020for valves DN25 VA5540A025for valves DN32 VA5540A032for valves DN40 VA5540A040for valves DN50 VA5540A050

Product accessory Type3/8, for valves DN10 VA5500A0101/2, for valves DN15 VA5500A0153/4 for valves DN20 VA5500A0201, for valves DN25 VA5500A0251 1/4, for valves DN32 VA5500A0321 1/2, for valves DN40 VA5500A0402, for valves DN50 VA5500A050

Product accessory Type3/8, for valves DN10 VA5090A0101/2, for valves DN15 VA5090A0153/4 for valves DN20 VA5090A0201, for valves DN25 VA5090A0251 1/4, for valves DN32 VA5090A0321 1/2, for valves DN40 VA5090A0402, for valves DN50 VA5090A050

Page 342: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-17

Other Pipework Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Other Pipework Valves

V5100 type valves are used as shutoff valves in hydronic heating and cooling systems. • The valves further have an integrated draining support. The draining function can be used with the

standard Kombi-System draining adapter (see Accessories further below). • They can also be used to connect the impulse tube of Kombi-3-plus, Kombi-2-plus and Kombi-PC

differential pressure controllers. Water-based heating and cooling systems.

With internal threads to ISO 7 (DIN 2999)

With external threads to DIN/ISO 228

Accessories

Service Parts

V5100 Stop Valve-3 Shutoff Valve

Materials Valve housing made of red bronze, spindle made of brass with EPDM O-rings and PTFE seat sealing, handwheel made of black plastic

Body pattern Y-pattern

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN16

Draining/filling support yes

Connection of accessories

through spindle

Place in installation supply or return

Additional description • Valve body made of corrosion-resistant red bronze • Integrated draining function with adapter • High flow rates

DN size Kvs value Port connection Port diameter Typemm inch

10 2,5 internal threads Rp 3/8 V5100Y001015 2,5 internal threads Rp 1/2 V5100Y001520 7 internal threads Rp 3/4 V5100Y002025 7 internal threads Rp 1 V5100Y002532 22 internal threads Rp 1 1/4 V5100Y003240 22 internal threads Rp 1 1/2 V5100Y0040

DN size Kvs value Port connection Port diameter Typemm inch

10 2,5 external threads G 5/8 A V5100X001015 2,5 external threads G 3/4 A V5100X001520 7 external threads G 1 A V5100X002025 7 external threads G 1 1/4 A V5100X002532 22 external threads G 1 1/2 A V5100X003240 22 external threads G 1 3/4 A V5100X0040

Draining adapter VA3500A001

Replacement insert for valves DN10 and 15 VS1501S015

Replacement insert for valves DN20 and 25 VS1501S025

Replacement insert for valves for valves DN32 and 40 VS1501S040

Page 343: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-18

Other Pipework Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

The V135 is a three-way mixing or diverting valve for hot water heating systems. It is typically used with a T100R or T100RS thermostat for hot water control applications, e.g. temperature control of underfloor heating systems.

V135B with internal threads

V135C with external threads

Accessories

V135 Diverting and Mixing Valve

Valve type 3-way mixing/diverting valve

Materials Valve housing made of red bronze; valve insert made of brass and plastic with EPDM O-rings and soft seals; handwheel cap made of white plastic; union-nuts and tailpieces made of brass

Action stem extension opens A-AB

Close off pressure with 90N motor

10 bar

Stroke 2 mm

Media temp. 2 ... 120 oC

Pressure rating PN16

Flow char. linear

Additional description • Balanced valve insert for high differential pressure resi-stance• Small stroke with high kv-value• Robust red bronze valve housing• Handwheel cap supplied with valve• Upper spindle sealing can be replaced under system pressure

DN size Connection diameter Kvs value Port connection Typemm inch

15 G 1/2 2,8 internal threads V135-1/2B20 G 3/4 3,2 internal threads V135-3/4B25 G1 5 internal threads V135-1B32 G1 1/4 5 internal threads V135-11/4B

DN size Connection diameter Kvs value Port connection Typemm inch

15 R 1/2 2,8 external threads V135-1/2C20 R 3/4 3,2 external threads V135-3/4C25 R1 5 external threads V135-1C32 R1 1/4 5 external threads V135-11/4C

Valve insert V135A-1/2VE

Valve insert V135A-1VE

Valve insert V135A-11/2VE

Thermostat with remote sensor (screw-in sensor) With R1/2" immersion pocket, Setting range 10...50C (50...122F)

T100R-AA

Thermostat with remote sensor (screw-in sensor) With R1/2" immersion pocket, Setting range 30...70C (86...158F)

T100R-AB

Thermostat with remote sensor (screw-in sensor) With R1/2" screw in sensor, Setting range 10...50C (50...122F)

T100RS-DA

Thermostat with remote sensor (screw-in sensor) With R1/2" screw in sensor, Setting range 30...70C (86...158F)

T100RS-DB

Page 344: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-19

Other Pipework Valves

2

3

4

5

6

7

8

10

9

11

12

13

14

Two-port valve for use with T100R/RS thermostat The V136 is a two-way control valve for hot water heating systems. It is typically used with a T100R or T100RS thermo-stat for hot water control applications, e.g. temperature control of DHW cylinder loading

Internal threads

Thermostat with remote sensor (screw-in sensor)

T100

R-AA

T100

R-AB

• • V135-1/2B• • V135-3/4B• • V135-1B• • V135-11/4B• • V135-1/2C• • V135-3/4C• • V135-1C• • V135-11/4C

V136 Control Valve, for use with T100R/RS Thermostat

Valve type 2-way valve

Materials Valve housing made of red bronze; valve insert made of brass and plastic with EPDM O-rings and soft seals

Action NO (valve closes when stem retracts)

Medium type water or water-glycol mixture according to VDI 2035

Stroke 4 mm

Media temp. 2 ... 120 oC

Pressure rating PN16

Port connection internal threads

Flow char. equal perc.

Additional description • High differential pressure resistance• Robust red bronze valve housing• Spindle sealing can be replaced under system pressure

DN size Connection diameter Kvs value Typemm inch

15 G 1/2 1 V136-15B20 G 1 2,5 V136-25B

With R1/2" immersion pocket Setting range 10...50C (50...122F) T100R-AA

With R1/2" immersion pocket Setting range 30...70C (86...158F) T100R-AB

With R1/2" screw in sensor Setting range 10...50C (50...122F) T100RS-DA

With R1/2" screw in sensor Setting range 30...70C (86...158F) T100RS-DB

Page 345: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

14-20

Other Pipework Valves

http://products.ecc.emea.honeywell.com/europe

2

3

4

5

6

7

8

9

10

11

12

13

14

Two-way measuring and control valve PN16, normally open, flat sealing.For use on the return of heat exchangers, for example fan coil units or chilled ceilings. They regulate the room temperature by controlling the flow in connection with an actuator. Flow can either be pre-set according to diagram or by flow measurement.

Accessories

V9406 Verafix-Cool two-way measuring and control valve PN16

Materials body red bronze, stem stainless steel, plug brass

Action normally open

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 130 oC

Pressure rating PN16

Flow char. linear

Stroke 3 mm

Closing dimension 11,5 mm

Body-head connection M30 x 1,5

Port connection ext. thread flat sealing

Colour of protection cap white

DN size 15 mm

Connection diameter G 3/4 inch

Kvs value 2,5

Additional description • Valve is supplied with protection and adjustment cap.• Suitable connections see 'Connections for Cooling Valves'.

TypeV9406DX015

Draining adapter VA3300A001

Measuring adapter VA3301A001

Special verafix key VA8300A001

BasicMES 2 handheld measuring computer VM242A0101

Page 346: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

15

16

17

18

19

20

21

22

24

23

25

26

27

28

Hydronic zoning Page

Zone Valves 15-2

Page 347: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

15-2

Zone Valves

http://products.ecc.emea.honeywell.com/europe

15

16

17

18

19

20

21

22

23

24

25

26

27

28

Zone Valves

Motorized spring-return 2-port hydronic zone valvesHoneywell V4043C 2-port hydronic valves are used in domestic and small commercial heating and cooling applications to control the flow of hot or cold water

Motorized spring-return 3-port hydronic zone valvesHoneywell V4044C and F 3-port hydronic valves are used in domestic and small commercial heating and cooling applications to control the flow of hot or cold water

V4043C Motorized Zone Valves

Materials Brass valve housing, zinc-plated steel actuator cover and base

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 5 ... 88 oC

Ambient temperature ... 50 oC

Max. operating pressure 8,6 bar

Power supply 220-240V, 50Hz

Input signal SPST

Power loss action valve closed

Type of terminals flying lead

Cable length 1000 mm

Valve type 2-way

Port connection internal threads

Port diameter Kvs value Max. differential pressure for close-off Typeinch bar

1/2 3 1,38 V4043C12553/4 6,9 0,55 V4043C1263

1 8,6 0,45 V4043C1271

V4044C, V4044F Motorized Zone Valves

Materials Brass valve housing, zinc-plated steel actuator cover and base

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 5 ... 88 oC

Ambient temperature ... 50 oC

Max. operating pressure 8,6 bar

Power supply 220-240V, 50Hz

Input signal SPST

Power loss action valve closed

Type of terminals flying lead

Cable length 1000 mm

Valve type 3-way diverting

Port connection internal threads

Page 348: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

15-3

Zone Valves

15

16

17

18

19

20

21

22

24

23

25

26

27

28

V4044C Motorized zone valve

V4044F Motorized zone valve with auxiliary switch

Balanced motorized 2-port or 3-port hydronic valves• Suitable valve bodies are listed in product group 'VC Series Motorized Zone Valves - Valve Bodies'

Honeywell VC Series balanced 2-position hydronic valves are used in domestic and small commercial heating and cooling applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly

VC Actuator

Accessories

End switch function/capacity Port diameter Kvs value Max. differential pressure for close-off Typeinch bar

– 1/2 3 1,4 V4044C1452– 3/4 6 0,7 V4044C1460– 1 8,1 0,55 V4044C1478

End switch function/capacity Port diameter Kvs value Max. differential pressure for close-off Typeinch bar

yes; SPDT 3/4 6 0,7 V4044F1000yes; SPST 1 8,1 0,55 V4044F1034

VC Series Motorized Zone Valves - Actuators

Materials Actuator cover and base made of plastic

Ambient temperature ... 65 oC

Type of terminals Molex(TM) socket

Power supply Input signal Type24V, 50-60Hz SPDT VC2010ZZ00

230V, 50-60Hz SPST VC4012ZZ00230V, 50-60Hz SPDT VC6012ZZ00

24V, 50-60Hz SPST VC8010ZZ00

VC Series 3-wire cable with Molex(TM) plug 40007035-005

Page 349: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

15-4

Zone Valves

http://products.ecc.emea.honeywell.com/europe

15

16

17

18

19

20

21

22

23

24

25

26

27

28

Balanced motorized 2-port or 3-port hydronic valves• Suitable actuators are listed in product group 'VC Series Motorized Zone Valves - Actuators'

Honeywell VC Series balanced 2-position hydronic valves are used in domestic and small commercial heating and cooling applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly

VC Zone Valve (2-port)

VC Diverting Valve (3-port)

Service Parts

VC Series Motorized Zone Valves - Valve Bodies

Materials Valve housing made of red bronze, cartridge made of plastic with stainless steel spindle

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 1 ... 95 oC

Max. operating pressure 20 bar

Max. differential pressure for close-off

4 bar

Valve type Port connection Port diameter Kvs value Typeinch

2-way internal threads 1 6 VCZAP10002-way external threads 1 6 VCZAQ1000

Valve type Port connection Port diameter Kvs value Typeinch

3-way diverting external threads 3/4 6,9 VCZMG60003-way diverting internal threads 3/4 7 VCZMH60003-way diverting internal threads 1 7,7 VCZMP60003-way diverting external threads 1 7,7 VCZMQ6000

VC Series replacement cartridge for 2-port zone valves, on/off VCZZ1000

VC Series replacement cartridge for 3-port diverting valves, on/off VCZZ6000

Page 350: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Boiler Room Valves Page

Safety Controls 16-2Filling Valves and Refilling Units 16-7Other Boiler Controls 16-13

Page 351: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-2

Safety Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Safety Controls

Membrane safety valves of this type are used to protect closed heating systems according to EN 12828.In accordance with statutory requirements, the diaphragm safety valve is preset to the required fixed set pressure by the manufacturer and is sealed with an embossed security cap marked with the test badge and pressure rating to prevent unauthorised tampering with the setting. Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap. The preset pressure is embossed on the security cap.

with 1/2" internal threads on inlet and outlet

with 1/2" internal threads on inlet and 3/4" on outlet

with 3/4" internal threads on inlet and outlet

with 3/4" internal threads on inlet and 1" on outlet

with 1/2" external threads on inlet and 3/4" internal threads on outlet

Diaphragm safety valve for closed heating systems, SM110

Approvals Certified to Pressure Equipment Directive 97/23/EC, Refe-rence No. CE 0036

Media • Water or glycol-water mixture,according to VDI 2035• Liquids of the fluid group 1 and 2 (pressure device guideline,

item 9) which do not affect the materials used.

Materials Brass housing; spring steel adjustment spring; high grade synthetic material security cap; hot water resistant elastomer diaphragm

Mounting position horizontal

Max. media temperature 120 oC

Additional description • Opening pressure factory preset to 1.5, 2.0, 2.5, 3.0, 4.0 or 6.0 bar

• Standardised discharge connection• With lifting device• Protected against subsequent changing of the default settings

Set pressure (bar) Port connection Type2,5 internal threads SM110-1/2ZA2.5

3 internal threads SM110-1/2ZA3.0

Set pressure (bar) Port connection Type1,5 internal threads SM110-1/2A1.5

2 internal threads SM110-1/2A2.02,5 internal threads SM110-1/2A2.5

3 internal threads SM110-1/2A3.04 internal threads SM110-1/2A4.06 internal threads SM110-1/2A6.0

Set pressure (bar) Port connection Type2,5 internal threads SM110-3/4ZA2.5

3 internal threads SM110-3/4ZA3.0

Set pressure (bar) Port connection Type1,5 internal threads SM110-3/4A1.52,5 internal threads SM110-3/4A2.5

3 internal threads SM110-3/4A3.04 internal threads SM110-3/4A4.0

Set pressure (bar) Port connection Type1,5 internal and external threads SM110-1/2AA1.5

2 internal and external threads SM110-1/2AA2.053 internal and external threads SM110-1/2AA3.05

Page 352: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-3

Safety Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

The SM120 diaphragm safety valve provides the last line of security for heating systems if the prescribed safety controls fail. In an emergency they must therefore have the capacity to discharge the whole contents of a cylinder in the form of steam. In normal system use they do not come into operation.For hydronic heating systems to DIN 4751.

SM120 with 2,5 bar set pressure for closed heating systems

SM120 with 3,0 bar set pressure for closed heating systems

Diaphragm safety valve for closed heating and solar installations, SM120

Approvals Construction tested to TRD 721

Materials Brass housing and spring bonnet with hot water resistant elastomer diaphragm and seal disc; high quality plastic venting knob

Media water

Max. media temperature 120 oC

Port connection internal threads

Plant output Type50 kW (45.000 kcal/h) SM120-1/2A100 kW (90.000 kcal/h) SM120-3/4A200 kW (175.000 kcal/h) SM120-1A350 kW (300.000 kcal/h) SM120-11/4A

Plant output Type50 kW (45.000 kcal/h) SM120-1/2B100 kW (90.000 kcal/h) SM120-3/4B200 kW (175.000 kcal/h) SM120-1B350 kW (300.000 kcal/h) SM120-11/4B

Page 353: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-4

Safety Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Membrane safety valves of this type are used to protect closed hot drinking water systems according to DIN 1988 and DIN 4753-1.In accordance with statutory requirements, the diaphragm safety valve is preset to the required fixed set pressure by the manufacturer and is sealed with an embossed security cap marked with the test badge and pressure rating to prevent unauthorised tampering with the setting. Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap. The preset pressure is embossed on the security cap.

with 1/2" internal threads on inlet and outlet

with 1/2" internal threads on inlet and 3/4" on outlet

with 3/4" internal threads on inlet and outlet

with 3/4" internal threads on inlet and 1" on outlet

Diaphragm safety valve for closed hot drinking water systems, SM150

Approvals Certified to Pressure Equipment Directive 97/23/EC, Refe-rence No. CE 0036

• Meets KTW recommendations for potable water

Media The membrane safety valve is only suitable to drain drinking water from closed hot drinking water systems according to DIN 1988 and DIN 4753-1 for protection against exceeding pressure

• Water

Materials Brass housing; spring steel adjustment spring; high grade synthetic material security cap; hot water resistant elastomer diaphragm

Mounting position horizontal

Max. media temperature 95 oC

Port connection internal threads

Additional description • Opening pressure factory preset to 6.0, 7.0, 8.0 or 10.0 bar• Standardised discharge connection• With lifting device• Protected against subsequent changing of the default settings

Set pressure (bar) Type6 SM150-1/2ZA7 SM150-1/2ZF8 SM150-1/2ZB

10 SM150-1/2ZC

Set pressure (bar) Type6 SM150-1/2A7 SM150-1/2F8 SM150-1/2B

10 SM150-1/2C

Set pressure (bar) Type6 SM150-3/4ZA7 SM150-3/4ZF8 SM150-3/4ZB

10 SM150-3/4ZC

Set pressure (bar) Type6 SM150-3/4A7 SM150-3/4F8 SM150-3/4B

10 SM150-3/4C

Page 354: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-5

Safety Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

The membrane safety valves of this type are used as last safe-guard for solar systems when the stipulated control and safety devices fail. They must therefore be capable to discharge the entire boiler output as steam in case of emergency. In accordance with statutory requirements, the diaphragm safety valve is preset to the required fixed set pressure by the manufacturer and is sealed with an embossed security cap marked with the test badge and pressure rating to prevent unauthorised tampering with the setting. Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap. The preset pressure is embossed on the security cap.

with 1/2" internal threads on inlet and outlet

with 1/2" internal threads on inlet and 3/4" on outlet

with 3/4" internal threads on inlet and outlet

with 3/4" internal threads on inlet and 1" on outlet

Diaphragm safety valve for solar systems, SM180

Approvals Certified to Pressure Equipment Directive 97/23/EC, Refe-rence No. CE 0036

Media • Water or glycol-water mixture,according to VDI 2035• Liquids of the fluid group 1 and 2 (pressure device guideline,

item 9) which do not affect the materials used.

Materials Brass housing; spring steel adjustment spring; high grade synthetic material security cap; hot water resistant elastomer diaphragm

Mounting position horizontal

Max. media temperature 160 oC

Port connection internal threads

Additional description • Opening pressure factory preset to 2.5, 3.0, 4.0, 6.0, 8.0 or 10.0 bar• Standardised discharge connection• With lifting device• Protected against subsequent changing of the default settings

Set pressure (bar) Type2,5 SM180-1/2ZA2.5

3 SM180-1/2ZA3.04 SM180-1/2ZA4.06 SM180-1/2ZA6.08 SM180-1/2ZA8.0

10 SM180-1/2ZA10.0

Set pressure (bar) Type2,5 SM180-1/2A2.5

3 SM180-1/2A3.04 SM180-1/2A4.06 SM180-1/2A6.08 SM180-1/2A8.0

10 SM180-1/2A10.0

Set pressure (bar) Type2,5 SM180-3/4ZA2.5

3 SM180-3/4ZA3.04 SM180-3/4ZA4.06 SM180-3/4ZA6.08 SM180-3/4ZA8.0

10 SM180-3/4ZA10.0

Set pressure (bar) Type2,5 SM180-3/4A2.5

3 SM180-3/4A3.04 SM180-3/4A4.06 SM180-3/4A6.08 SM180-3/4A8.0

10 SM180-3/4A10.0

Page 355: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-6

Safety Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The FR 124 combustion regulator opens closes the air intake flap of solid fuel burners in proportion to the flow temperature.For solid fuel and multi-fuel heating installations to DIN EN12828

The TS131 temperature relief valve for heating systems according to EN 12828 is a self-acting valve which is activated by the flow temperature of the heat generator. It opens and discharges water from the heat generator or condensing coil at a flow temperature of 95C and thereby prevents a significant temperature rise in the heat generator.Multi-fuel boilers with integral water heating or condensing coils in closed solid-fuel fired heating systems to EN12828.

Accessories

FR124 Combustion regulator for solid fuel and multi-fuel burners

Materials High-quality plastic housing and adjuster knob with brass sensor pocket, galvanized steel lever rod and chain

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 115 oC

Product description Connection size G 3/4", chain length 1 m

Additional description Setting range 30 to 90oCelsius

TypeFR124-3/4A

TS131 Temperature relief valve with test facility and double sensor

Approvals Construction tested to EN14597 (TH119507)

Materials Brass housing, bonnet and immersion pocket; copper temperature sensor; copper capillary tube; brass valve piston; hot-water-resistant elastomer seals

Max. media temperature 95 oC

Connection size Rp 3/4" mm

Additional description • Immersion pocket with double heat sensors• Test facility• Capillary tube protected against kinking by steel sheath• Immersion pocket with external thread

Product description TypeCapillary tube with protection sheath 1300mm, with approved construction TS131-3/4ACapillary tube with protection sheath 4000mm TS131-3/4B

Piston guide complete for TS131 Connection size 3/4" TS131K-3/4S

Temperature motion transducer for TS131 Opening temperature 95C Capillary tube with protection sheath 1300mm

TS131TWG-3/4A

Temperature motion transducer for TS131 Opening temperature 95C Capillary tube with protection sheath 4000mm

TS131TWG-3/4B

Page 356: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-7

Filling Valves and Refilling Units

16

17

18

19

20

21

22

24

23

25

26

27

28

Filling Valves and Refilling Units

The VF06 filling valve permits simple and safe filling or refilling of closed heating systems. A pressure reducing valve, a check valve and a shut-off facility are combined into one unit. The pressure gauge connection enables fitting of a pressure gauge (accessory) to provide accurate checking of system pressure after filling.For closed heating systems to DIN 4751:

• Onto a heating circuit distributor manifold,• in combination with a water supply distributor manifold,• on a heating boiler via a fill hose, in the supply to or directly onto a heating boiler,• as a filling set for trouble-free and safe initial filling of a system.

Accessories

Service parts

Filling valve for closed heating systems, VF06

Approvals DIN/DVGW approved check valve

Materials Brass housing, plastic spring bonnet and valve cartridge, fibre-reinforced NBR diaphrgm, NBR seals

Media water

Max. media temperature 70 oC

Pressure rating PN16

Pressure setpoint range 0,5 ... 3 bar

Port connection external threads

Product description TypeWith hose union connector VF06-1/2AWith threaded union connector VF06-1/2B

Pressure gauge, range 0-4 bar MF126-A4

Hose connector with union nut and gasket 0903454

Connection set with threaded connector VST06-1/2A

Double ring wrench for removal of spring bonnet ZR06K

Spring bonnet assembly 0903445

Valve insert assembly D06FA-1/2

Check valve 2166200

Blanking plug with O-ring (pack of 5) S06K-1/4

Page 357: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-8

Filling Valves and Refilling Units

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The VF04 filling valve permits simple and safe filling or refilling of closed heating systems. A pressure reducing valve, a check valve and a shut-off facility are combined into one unit. The pressure gauge connection enables fitting of a pressure gauge (accessory) to provide accurate checking of system pressure after filling.For closed heating systems to DIN 4751:

• Onto a heating circuit distributor manifold,• in combination with a water supply distributor manifold,• on a heating boiler via a fill hose, in the supply to or directly onto a heating boiler,• as a filling set for trouble-free and safe initial filling of a system.

Accessories

Filling valve for closed heating systems, VF04

Approvals DIN/DVGW approved check valve

Materials Brass housing dezincification resistant, high grade synthetic material spring bonnet, fibre-reinforced NBR diaphragm, NBR seals

Media water

Max. media temperature 70 oC

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Product description With internal and external threads

TypeVF04-1/2E

Pressure gauge, range 0-4 bar MF126-A4

Hose connector with union nut and gasket 0903454

Connection set with threaded connector VST06-1/2A

Pressure gauge, range 0-10 bar M39K-A10

Page 358: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-9

Filling Valves and Refilling Units

16

17

18

19

20

21

22

24

23

25

26

27

28

The refilling combination serves filling and refilling of closed heating systems to DIN EN 12828:2003. It can be connected in accordance to EN 1717 constantly with the drinking water supply. The refilling combination combines backflow preventer, pressure reducing valve and two ball valves in one appliance. All devices for refilling a heating installation according to conforming standards are contained.

Standard version

Refilling combination, compact construction, NK295C

Materials Dezincification-resistant brass housing; discharge connection, valve cartridge, valve insert and spring hood in high-grade synthetic material; high-grade synthetic material check valve; seals in NBR; spring steel adjustment spring; isolation shell in EPP

Media Water without inhibitors

Max. media temperature 65 oC

Pressure setpoint range 1,5 ... 6 bar

Product description with 1/2" threaded connections

Additional description • Compact construction• Constant connection with the drinking water supply in accor-

dance with EN1717 by hose line or piping is possible• Corrosion resistant by use of brass and stainless steel• Low pressure loss and high flow rate• Optimal protection of the drinking water supply system• Triple security - two check valves and a discharge valve sepa-

rate the backflow preventer into three pressure zones• Field-tested reliable pressure reducing valve• Pressure reducing valve with inlet pressure balancing - inlet

pressure fluctuation does not influence the outlet pressure• Outlet pressure adjustable and directly at the pressure gauge

readable• DIN/DVGW approved check valve• Variable connection options to the heating system• Low maintenance effort• Meets KTW recommendations for potable water

TypeNK295C-1/2A

Page 359: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-10

Filling Valves and Refilling Units

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The refilling combination serves filling and refilling of closed heating systems to DIN EN 12828:2003. It can be connected in accordance to EN 1717 constantly with the drinking water supply. The refilling combination combines backflow preventer, pressure reducing valve and two ball valves in one appliance. All devices for refilling a heating installation according to conforming standards are contained.

Standard version with 1/2" threaded connections

Accessories

Spare Parts

Refilling combination, NK300

Materials Dezincification resistant brass housing, discharge connection, valve cartridge, valve insert and spring hood in high-grade synthetic material, fibre-reinforced NBR diaphragm, NBR and EPDM seals, spring steel adjustment spring, stainless steel fine filter sieve.

Media water

Max. media temperature 65 oC

Pressure rating PN10

Pressure setpoint range 1,5 ... 4 bar

Port connection external threads

TypeNK300-1/2A

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Double ring spanner for removal of spring hood and filter bowl. ZR06K

Maintenance set for refilling combination NK300 for use with TK295 resp. TKA295. WS300NK

Replacement valve set D06FA-1/2

Blanking Plug set with 0-ring (5 pieces) S06K-1/4

Pressure gauge, range 0-4 bar M07M-A4

Page 360: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-11

Filling Valves and Refilling Units

16

17

18

19

20

21

22

24

23

25

26

27

28

The refill unit continually monitors the pressure in a connected system, e.g. a heating circuit, and maintains it automatically. Refill units of this type enable permanent connection of closed heating systems to the drinking water network. Together with the backflow preventer the unit corrosponds to EN1717. Control unit, quantity counter and pressure regulation are integrated in one device. An alarm message is given as well as message contact on the switching of an error message system or central building control system.

Electronic refill unit

Electronic refill unit with backflow preventer BA

Electronic refill unit with backflow preventer CA

Accessories

Electronic refill unit, NK300T

Media Drinking water

Protection class IP 54 according to EN 60529 (ensured only with correctly connected cable, correct installation of the insulation shell elements and horizontal installation position)

Max. ambient temperature

50 oC

Body material brass, dezincification resistant

Port connection external threads

Mounting position horizontal

Maximum flow (qs) 0,8 m3/h

Connection diameter 1/2 inch

Additional description • Fully automatic, electronically monitored filling • Simple handling with three-button keypad and display• Monitoring and registration of the feed amounts• Electronic pressure monitor and switching off in case of leaks• Internal and external alarm in case of malfunction• User-friendly, time-optimised system initial filling• Very flexible use due to modular construction (backflow pre-

venter CA, backflow preventer BA, softening unit VE)

TypeNK300T-1/2A

TypeNK300T-1/2ABA

TypeNK300T-1/2ACA

Cutting unit, standard version with threaded connection 1/2" VE300-1/2A

0,75l cartridge with ionic exchange resin P300-S

3.5l cartridge with ionic exchange resin P300-L

Adapter to fit the softening unit to a 3/4 male connection. AD300

Page 361: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-12

Filling Valves and Refilling Units

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The softening unit of the Honeywell NK300soft facilitates the softening of heating water according to VDI-guideleine 2035/I. Limescale and thereby caused damages and malfunction in hot water heating system (DIN EN 12828) are avoided efficiently.The refilling combination fitted on the inlet and based on a BA-type backflow preventer protects the potable water supply against back flow of heating water according to DIN EN 1717.

• Intergrated water meter simplify the determination of cartridge exchang• Easy exchange of cartridge without tools• Constant connection with the drinking water supply in accor-dance with EN1717 by hose line or pip-

ing is possible• Optimal protection of the drinking water supply system• Backflow preventer approved for noise level protection, class 2• Pressure reducing valve approved for noise level protection, class 1• Pressure reducing valve with inlet pressure balancing - inlet pressure fluctuation does not influence

the outlet pressure• Outlet pressure adjustable and directly at the pressure gauge readable

Standard version with 1/2" threaded connections and 600micron filter in the refilling combination

Version with 1/2" threaded connections and 25micron filter in the refilling combination

Accessories

Spare Parts

Refilling combination with softening unit , NK300soft

Materials Dezincification-resistant brass housing; discharge valve, cartridge insert, valve insert, mechanical components of the blending unit and spring bonnet made of high-quality plastic; fibre-reinforced NBR diaphragm; seals in NBR and EPDM; spring steel adjustment spring; stainless steel fine filter mesh; polypropylene cartridge

Media water

Max. media temperature 30 oC

Pressure rating PN10

Pressure setpoint range 1,5 ... 4 bar

Port connection external threads

Kvs value 0,45

Housing (HxWxD) 524 mm; 495 mm; - mm

Additional description Suitable for heating systems with the following materials: steel, copper, copper alloys and plastics. Treated water has modified corrosive chemical parameters. Conditioning by means of inhibitors is to be provided for separately.

TypeNK300soft-1/2A

TypeNK300soft-1/2AZ25

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Double ring spanner for removal of spring hood and filter bowl. ZR06K

Maintenance set for refilling combination NK300 for use with TK295 resp. TKA295. WS300NK

Replacement valve set D06FA-1/2

Blanking Plug set with 0-ring (5 pieces) S06K-1/4

Pressure gauge, range 0-4 bar M07M-A4

Water flow meter WZ300

Air bleed valve 2421100

Cartridge 0,75l P300-S

Cartridge 3,5l P300-L

Page 362: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-13

Other Boiler Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

Other Boiler Controls

The DU144 automatic bypass valve controls water flow in the heating circuit according to the water pressure across it and is used to maintain a minimum flow rate through the boiler and to limit circulation pressure when other water paths are closed.A bypass circuit must be installed if the Boiler manufacturer requires one, or specifies that a minimum flow rate has to be maintained whilst the Boiler is firing. The use of automatic bypass valves becomes particularly important when heating systems include large numbers of thermostatic radiator valves (TRVs) - whilst the TRVs are open the automatic bypass valve remains closed, however, as the TRVs start to close, the auto-matic bypass valve starts to open maintaining the required water flow through the boiler. Using an automatic bypass valve is also likely to reduce noise in systems caused by excess water velocities. Because manual or fixed position valves do not regulate the flow and allow water to bypass even when it is not necessary, building regulations require bypass circuits to use automatic bypass valves and not fixed position valves.

DU144

DU144 Automatic Bypass Valve

Materials • Valve housing, fittings, bonnet and handwheel made of brass• Spindle made of stainless steel• All sealings made of EPDM and NBR• Protection cap made of red plastic

Medium type water or water-glycol mixture according to VDI 2035

Media temp. 2 ... 110 oC

Max. operating pressure 10 bar

Differential pressure setpoint range

0,1 ... 0,6 bar

Kvs value 2,3

Product description Typewith compression fittings for 22mm copper pipe DU144A1001with 3/4" external threads DU144A1002with 3/4" internal threads DU144A1003

Page 363: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-14

Other Boiler Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The DU145 automatic bypass and differential pressure valve is used to maintain a constant differential pressure in a heating system. It reduces flow noise in a system, particularly as thermostatic radiator valves are closed. The boiler return temperature is raised and this reduces corrosion caused by flue gas condensation. In addition, when radiator valves are closed it also maintains flow over the temperature sensor on the boiler to ensure proper operation of external temperature compensation controls. On gas-fired water heaters it guarantees a minimum flow circulation when thermostats or radiator valves are closed.For pump-driven warm water heating systems, e.g.:

• On heating systems with three-way or four-way mixing valves, or• on gas-fired hot water circulation heating systems.

Accessories for DU 145-3/4 A

Accessories for DU 145-3/4 E

DU145 Automatic bypass and differential pressure valve

Materials Brass housing and fittings, plastic sping bonnet assembly and valve disc, stainless steel spring, EPDM seals

Body pattern angle

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 110 oC

Max. operating pressure 3 bar

Differential pressure setpoint range

0,1 ... 0,6 bar

Additional description For system capacities up to approx. 70 kW (60.000 kcal/h)

Product description Port connection TypeSupplied with externally threaded connections external threads DU145-3/4A

– internal threads DU145-3/4E

2 soldering connections for 22 mm pipe VST06-3/4B

Compression ring with backnut, 3/4 x 18 mm ZS109M-3/4G

Compression ring with backnut, 3/4 x 22 mm ZS109M-3/4H

2 compression rings with backnuts and support inserts, 3/4 x 18 mm ZS109M-3/4GS

2 compression rings with backnuts and support inserts, 3/4 x 18 mm ZS109M-3/4GS

Page 364: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-15

Other Boiler Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

The DU146 automatic bypass and differential pressure valve is used to maintain a constant differential pressure in a heating system. It reduces flow noise in a system, particularly as thermostatic radiator valves are closed. The boiler return temperature is raised and this reduces corrosion caused by flue gas condensation. In addition, when radiator valves are closed it also maintains flow over the temperature sensor on the boiler to ensure proper operation of external temperature compensation controls. On gas-fired water heaters it guarantees a minimum flow circulation when thermostats or radiator valves are closed.For pump-driven warm water heating systems, e.g.:

• On heating systems with three-way or four-way mixing valves, or• on gas-fired hot water circulation heating systems.

Accessories

DU146 Automatic bypass and differential pressure valve with differential pressure indicator

Materials Brass housing, fittings and valve disc, plastic spring bonnet assembly, composite glass display tube, stainless steel spring, EPDM seals

Body pattern angle

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 110 oC

Max. operating pressure 3 bar

Differential pressure setpoint range

0,05 ... 0,5 bar

Port connection internal threads

Additional description Special versions available on request.

Product description TypeFor installations up to approx. 70 kW (60.000 kcal/h) DU146-3/4AFor installations up to approx. 232 kW (200.000 kcal/h) DU146-11/4A

Indicator tube assembly, consisting of indicator tube, inner tube, spring, indicator piston and 5 O-rings

DU146AH-A

Page 365: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-16

Other Boiler Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The DU146 M automatic bypass and differential pressure valve is used to maintain a constant differential pressure in a heating system. It reduces flow noise in a system, particularly as thermostatic radiator valves are closed. The boiler return temperature is raised and this reduces corrosion caused by flue gas condensation. In addition, when radiator valves are closed it also maintains flow over the temperature sensor on the boiler to ensure proper operation of external temperature compensation controls. On gas-fired water heaters it guarantees a minimum flow circulation when thermostats or radiator valves are closed.Specially designed for disctrict heating systems, but can also be used for pump-driven warm water heating systems.

The E121 air vent is a reliable automatic venting device and is suitable for venting air or gas from heating systems or heat process installations.For hot water heating systems, radiators, wall- and ceiling-mounted air heaters, air collection vessels, pipework circuits, boilers and air separators. Not suitable for mineral oil or liquids with mineral-oil based additives.

Service parts

DU146 M Automatic bypass and differential pressure valve for district heating sys-tems

Materials Brass housing, spring bonnet and valve disc, plastic adjuster knob, stainless steel spring, EPDM seals

Body pattern angle

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 130 oC

Max. operating pressure 16 bar

Differential pressure setpoint range

0,05 ... 0,5 bar

Port connection internal threads

Additional description Special versions available on request.

Product description TypeFlow rate V = 3 cubic metres/h DU146M-3/4AFlow rate V = 10 cubic metres/h DU146M-11/4A

E121 Automatic air vent

Materials Brass housing and lid, high-grade plastic float, heat-resistant elastomer seal components

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 110 oC

Pressure rating PN10

Port connection external threads

Additional description With fitted Z 121 A shut-off valve cleaning or replacement of the seal and inner components can be carried out without draining the system.

Product description TypeStandard version, connection size R 3/8 E121-3/8AStandard version, connection size R 1/2 E121-1/2A

Shut-off valve, packing unit 12 pcs, for connection size R3/8" Z121-3/8

Shut-off valve, packing unit 12 pcs, for connection size R1/2" Z121-1/2

Air vent cap with float, packing unit 54 pcs, threaded connection 44x19, min. installation depth for float 46mm

X121-AA

Page 366: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-17

Other Boiler Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

The air vent is used to automatically ventilate fluid-filled systems, preferably in solar installations.Air in heating systems and other fluid-filled systems frequently causes disruptions in water cycles, as well as corrosion and noise. Therefore pay particular attention to a good ventilation.

Standard version

Accessories

The air vent is used to automatically ventilate fluid-filled systems, preferably in solar installations.Air in heating systems and other fluid-filled systems frequently causes disruptions in water cycles, as well as corrosion and noise. Therefore pay particular attention to a good ventilation.

Standard version

Accessories

Minival Solar - Automatic air vent for solar installations, E121S

Media Water

Body material brass

Max. media temperature 150 oC

Additional description Packing unit: 12 pieces• Absolutely drip free• Long-term reliability• High ventilation capacity• Cleaning or exchange of the sealing and internal parts after ad-

ditional installation of the AVSOLAR shutoff valve is possible without emptying the system

• Extremely quick reaction• Particularly compact

TypeE121S-3/8AE121S-1/2A

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 3/8

AVSOLAR-3/8

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 1/2

AVSOLAR-1/2

Elite Solar - Automatic air vent for solar installations, E125S

Media Water

Body material brass

Port connection external threads

Max. media temperature 150 oC

Additional description • Absolutely drip free• Long-term reliability• High ventilation capacity• Cleaning or exchange of the sealing and internal parts after ad-

ditional installation of the AVSOLAR shutoff valve is possible without emptying the system

• Extremely quick reaction• Particularly compact

TypeE125S-3/8AE125S-1/2A

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 3/8

AVSOLAR-3/8

Shutoff valve, Brass housing, high-grade, temperature-resistant plastic internal parts, hot water-resistant elastomer sealing ring, connection size 1/2

AVSOLAR-1/2

Page 367: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-18

Other Boiler Controls

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The EA122 air vent is a reliable automatic venting device and is suitable for venting air or gas from heating systems or heat process installations.For hot water heating systems, radiators, wall- and ceiling-mounted air heaters, air collection vessels, pipework circuits, boilers and air separators. Not suitable for mineral oil or liquids with mineral-oil-based additives

Service parts

The sludge and air separator serves to separate sludge and air from the heating system. It is equipped with a sludge and contamination reduction feature that functions according to the cyclone principle.This guarantees an effective separation of the particles. There is an optional phosphate cartridge available to prevent corrosion in aluminium-free heating systems.

Standard version

Accessories

Spare Parts

EA122 Automatic air vent with integrated shut-off and leak protection

Materials Brass connections, high-grade plastic float, float housing and lid, heat-resistant elastomer seal components

Medium type water or water-glycol mixture according to VDI 2035

Max. media temperature 110 oC

Pressure rating PN6

Port connection external threads

Additional description • Integrated shut-off facility.• Expanding discs to prevent leakage.• Integrated vacuum break.• Cleaning and replacement of seal and inner components can

be carried out without draining the system.

Product description TypeConnection sizes R 1/8 and R 3/8 EA122-AAConnection sizes R 1/4 and R 3/4 EA122-BA

Lid with float 0900577

Leak protection discs (pack of 5) 0900761

Sludge and Air Separator, HF49

Body material brass, dezincification resistant

DN size 25 mm

Max. media temperature 90 oC

Max. pressure 10 kPa

Nominal flow 3600 kg/h

Kvs value 7,8

Additional description The sludge and air separator is installed in the heating circuit (feed and return line) and serves to separate sludge and air from the heater water.

TypeHF49-1A

Phosphate cartridge for protection of the heater system against corrosion. Use only in heater systems without aluminium materials.

PE49

Venting insert EE49

Ball valve KH49

Page 368: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-19

Other Boiler Controls

16

17

18

19

20

21

22

24

23

25

26

27

28

The softening unit of the Honeywell VE300 facilitates the softening of heating water. Limescale and thereby caused damages and malfunction in hot water heating system are avoided efficiently.According to DIN EN 1717 the refilling combination NK300 have to be fitted on the inlet to protect the portable water supply.

• Intergrated water meter simplify the determination of cartridge exchang• Easy installation and exchange of cartridge without tools• Constant connection with the drinking water supply in accordance with EN1717 by hose line or piping

is possible in case of using a NK300

Standard version with threaded connection R1/2"

Accessories

Spare Parts

Softening unit for heating systems, VE300

Materials Dezincification-resistant brass housing; discharge valve, cartridge insert, valve insert, mechanical components of the blending unit and spring bonnet made of high-quality plastic; fibre-reinforced NBR diaphragm; seals in NBR and EPDM; spring steel adjustment spring; stainless steel fine filter mesh; polypropylene cartridge

Media water

Max. media temperature 30 oC

Kvs value 0,45

Additional description Suitable for heating systems with the following materials: steel, copper, copper alloys and plastics. Treated water has modified corrosive chemical parameters. Conditioning by means of inhibitors is to be provided for separately.

TypeVE300-1/2A

Shutoff valve Connection size 1/2" 2192900

Soldered connection set _VST06-B

0,75l cartridge with ionic exchange resin P300-S

3.5l cartridge with ionic exchange resin P300-L

Adapter to fit the softening unit to a 3/4" male connection AD300-1/2

Noise protected pressure reducing valve with setting scale. _D06F

Backflow Preventer to protect drinking water systems against back pressure, backflow and withdrawal. Protection against fluids up to and including fluid category 4 acc. to DIN EN1717.

_BA295

Refilling combination Liquid catagory 4, with pressure gauge, shutoff valve and isolating shell

NK300-1/2A

Water flow meter WZ300

Air bleed valve 2421100

Page 369: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16-20 http://products.ecc.emea.honeywell.com/europe

Page 370: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Metering Page

Hydronic Meters 17-2Calculators and system components 17-16

Page 371: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-2

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Hydronic Meters

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.Metering of cold or warm potable water.

EW100 Series for cold water

EW100 Series for warm water

Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

Set of union nut, sealing and Sanpress red bronze crimp fitting (two packs per meter required)

Set of union nut, sealing and Mapress stainless steel crimp fitting (two packs per meter required)

Set of union nut, sealing and internally threaded red bronze tailpiece (two packs per meter required)

Clip on RF modules

EW100 Series Singlejet Water Meters DN15...20

Approvals MID

Features • Compact design• Rotatable counter• Retrofittable RF modules

Medium warm or cold potable water

Product description EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.

Measuring method single jet

Display functions Roller counter, 8-digit

Max. operating pressure 16 bar

Interface none (retrofittable)

Nominal flow DN size Length Connection Media temp. Typem3/h mm mm oC

1,5 15 110 G 3/4 B ... 30 EW1000AZ12012,5 20 130 G 1 B ... 30 EW1000AZ2001

Nominal flow DN size Length Connection Media temp. Typem3/h mm mm oC

1,5 15 110 G 3/4 B ... 90 EW1001AZ12012,5 20 130 G 1 B ... 90 EW1001AZ2001

For DN15, thread 1/2" EWA1500035

For DN20, thread 3/4" EWA1500042

For DN15, for 15mm pipe-diameter VA7404A015

For DN15, for 18mm pipe-diameter VA7404A018

For DN20, for 22mm pipe-diameter VA7404A020

For DN15, for 15mm pipe-diameter VA7403A015

For DN15, for 18mm pipe-diameter VA7403A018

For DN20, for 22mm pipe-diameter VA7403A020

For DN15, thread Rp1/2" VA7405A015

For DN20, thread Rp3/4" VA7405A020

Fixed network (AMR) module EW9106AFZ001

Mobile network (walk by) module EW9106AFZ002

Page 372: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-3

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

Single-jet water meter for cold or warm potable water up to 90 C. Available with pulse or RF output or without outputEW147 and EW148 Series water meters are used to meter the volume throughput in cold and warm potable water pipelines. They are suitable for vertical or horizontal riser or downpipe installation.

EW147 Series water meter for cold potable water

EW148 Series water meter for warm potable water

Accessories

EW147, EW148 Singlejet Potable Watermeters

Approvals • EC type approval to EO6: D98-6.131.09 (cold = EW147); D98-6.331.93 (warm = EW148)

• Metrological class: A BH (A - any position, B - horizontal)

Max. operating pressure 10 bar

Materials • Meter housing made of brass• Impeller and counter housing made of plastic

Measuring method single jet

Dynamic range 1:50

Medium Nominal flow Media temp. DN size Length Connection Interface Typem3/h oC mm mm

cold potable water 1,5 ... 30 15 80 G 3/4 B none EW147A1101cold potable water 1,5 ... 30 15 110 G 3/4 B none EW147A1201cold potable water 1,5 ... 30 15 130 G 3/4 B none EW147A1301cold potable water 2,5 ... 30 20 130 G 1 B none EW147A2001cold potable water 1,5 ... 30 15 80 G 3/4 B pulse EW147P1101cold potable water 1,5 ... 30 15 110 G 3/4 B pulse EW147P1201cold potable water 2,5 ... 30 20 130 G 1 B pulse EW147P2001

Medium Nominal flow Media temp. DN size Length Connection Interface Typem3/h oC mm mm

warm potable water 1,5 ... 90 15 80 G 3/4 B none EW148A1101warm potable water 1,5 ... 90 15 110 G 3/4 B none EW148A1201warm potable water 1,5 ... 90 15 130 G 3/4 B none EW148A1301warm potable water 2,5 ... 90 20 130 G 1 B none EW148A2001warm potable water 1,5 ... 90 15 80 G 3/4 B pulse EW148P1101warm potable water 1,5 ... 90 15 110 G 3/4 B pulse EW148P1201warm potable water 2,5 ... 90 20 130 G 1 B pulse EW148P2001

Set of two union nuts, sealings and externally threaded brass tailpieces, for DN15, thread 1/2"

EWA1500035

Set of two union nuts, sealings and externally threaded brass tailpieces, for DN20, thread 3/4"

EWA1500042

MAPRESS stainless steel fitting with sealing, connection size DN15, for 15mm pipe VA7403A015

MAPRESS stainless steel fitting with sealing, connection size DN15, for 18mm pipe VA7403A018

MAPRESS stainless steel fitting with sealing, connection size DN20, for 22mm pipe VA7403A020

Sanpress red bronze fitting with sealing, connection size DN15, for 15mm pipe VA7404A015

Sanpress red bronze fitting with sealing, connection size DN15, for 18mm pipe VA7404A018

Sanpress red bronze fitting with sealing, connection size DN20, for 22mm pipe VA7404A020

868MHz RF module for EW147A and EW148A EWA3004612

Page 373: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-4

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 to DN40 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.Metering of cold or warm potable water.

EW130 Series with M-Bus for cold water

EW130 Series with M-Bus for warm water

EW130 Series with RF for cold water

EW130 Series with RF for warm water

EW130 Series Multijet Water Meters DN15...40

Approvals MID

Features • Available with either M-Bus or RF• Electronic sensor control for flow rate recording• Optical interface included as standard• Adjustable reading date for billing• Rotatable calculator

Medium warm or cold potable water

Measuring method multi jet

Display functions LCD, 7-digit

Power source Lithium battery (10 year lifetime)

Nominal flow DN size Length Connection Max. operating pressure Media temp. Interface Typem3/h mm mm bar oC

2,5 15 110 G 3/4 B 10 0 ... 30 M-Bus EW1300BM12004 20 130 G 1 B 16 0 ... 30 M-Bus EW1300BM2000

6,3 25 260 G 1 1/4 B 16 0 ... 30 M-Bus EW1300BM360010 40 300 G 2 B 16 0 ... 30 M-Bus EW1300BM4600

Nominal flow DN size Length Connection Max. operating pressure Media temp. Interface Typem3/h mm mm bar oC

2,5 15 110 G 3/4 B 10 0 ... 90 M-Bus EW1301BM12004 20 130 G 1 B 16 0 ... 90 M-Bus EW1301BM2000

6,3 25 260 G 1 1/4 B 16 0 ... 90 M-Bus EW1301BM360010 40 300 G 2 B 16 0 ... 90 M-Bus EW1301BM4600

Nominal flow DN size Length Connection Max. operating pressure Media temp. Interface Typem3/h mm mm bar oC

2,5 15 110 G 3/4 B 10 0 ... 30 Radio (RF) EW1300BF12004 20 130 G 1 B 16 0 ... 30 Radio (RF) EW1300BF2000

6,3 25 260 G 1 1/4 B 16 0 ... 30 Radio (RF) EW1300BF360010 40 300 G 2 B 16 0 ... 30 Radio (RF) EW1300BF4600

Nominal flow DN size Length Connection Max. operating pressure Media temp. Interface Typem3/h mm mm bar oC

2,5 15 110 G 3/4 B 10 0 ... 90 Radio (RF) EW1301BF12004 20 130 G 1 B 16 0 ... 90 Radio (RF) EW1301BF2000

6,3 25 260 G 1 1/4 B 16 0 ... 90 Radio (RF) EW1301BF360010 40 300 G 2 B 16 0 ... 90 Radio (RF) EW1301BF4600

Page 374: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-5

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

Set of union nut, sealing and Sanpress red bronze crimp fitting (two packs per meter required)

Set of union nut, sealing and Mapress stainless steel crimp fitting (two packs per meter required)

Set of union nut, sealing and internally threaded red bronze tailpiece (two packs per meter required)

Ballvalve with internal threads

External M-Bus to RF module

Bluetooth optohead

For DN15, thread 1/2" EWA1500035

For DN20, thread 3/4" EWA1500042

For DN25, thread 1" EWA1500062

For DN40, thread 1 1/2" EWA1500072

For DN15, for 15mm pipe-diameter VA7404A015

For DN15, for 18mm pipe-diameter VA7404A018

For DN20, for 22mm pipe-diameter VA7404A020

For DN25, for 28mm pipe-diameter VA7404A025

For DN15, for 15mm pipe-diameter VA7403A015

For DN15, for 18mm pipe-diameter VA7403A018

For DN20, for 22mm pipe-diameter VA7403A020

For DN25, for 28mm pipe-diameter VA7403A025

For DN15, thread Rp1/2" VA7405A015

For DN20, thread Rp3/4" VA7405A020

For DN25, thread Rp1" VA7405A025

DN15, G1/2" internal thread EWA087HY004

DN20, G3/4" internal thread EWA087HY005

DN25, G1" internal thread EWA087HY006

For EW1300BM and EW1301BM EW9100AEZ001

For all EW130 EWA3001799

Page 375: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-6

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Honeywell EW170 Series Woltman water meters are used for flow measurement of cold or warm water in potable water systems. EW170xA (i.e. EW1700A and EW1701A) water meters have a mechanical roller counter and can be equipped with up to two reed switches for pulse output. EW170xB (i.e. EW1700B and EW1701B) water meters have an electronic counter and an M-Bus and ZVEI optical output.Metering of cold or warm potable water.

EW170 Series with mechanical counter for cold water

EW170 Series with mechanical counter for warm water

EW170 Series Woltman Bulk Water Meters DN50...125

Approvals • EW1700A: EC type approval• EW1700B: National approval

Features • Suitable for horizontal and vertical installation• Calibrated sealed measuring insert• Low pressure loss• Rugged design for longterm accuracy• Integrated outputs as standard

Medium warm or cold potable water

Measuring method woltmann wheel

Display functions • EW1700A: mechanical counter• EW1700B: LCD, 7-digit

Power source Lithium battery (10 year lifetime, EW170xB only)

Connection Flanges PN16

Max. operating pressure 16 bar

Nominal flow DN size Length Media temp. Interface Typem3/h mm mm oC

15 50 200 0 ... 30 none (retrofittable) EW1700AA500025 65 200 0 ... 30 none (retrofittable) EW1700AA560040 80 200 0 ... 30 none (retrofittable) EW1700AA650060 100 250 0 ... 30 none (retrofittable) EW1700AA7300

100 125 250 0 ... 30 none (retrofittable) EW1700AA8100

Nominal flow DN size Length Media temp. Interface Typem3/h mm mm oC

15 50 200 0 ... 90 none (retrofittable) EW1701AA500025 65 200 0 ... 90 none (retrofittable) EW1701AA560040 80 200 0 ... 90 none (retrofittable) EW1701AA650060 100 250 0 ... 90 none (retrofittable) EW1701AA7300

100 125 250 0 ... 90 none (retrofittable) EW1701AA8100

Page 376: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-7

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

EW170 Series with electronic counter and M-Bus for cold water

EW170 Series with electronic counter and M-Bus for warm water

Reed switch for pulse output, suitable for EW1700AA and EW1701AA

External RF module

External M-Bus module

Bluetooth optohead

Nominal flow DN size Length Media temp. Interface Typem3/h mm mm oC

15 50 200 0 ... 30 M-Bus EW1700BM500025 65 200 0 ... 30 M-Bus EW1700BM560040 80 200 0 ... 30 M-Bus EW1700BM650060 100 250 0 ... 30 M-Bus EW1700BM7300

100 125 250 0 ... 30 M-Bus EW1700BM8100

Nominal flow DN size Length Media temp. Interface Typem3/h mm mm oC

15 50 200 0 ... 90 M-Bus EW1701BM500025 65 200 0 ... 90 M-Bus EW1701BM560040 80 200 0 ... 90 M-Bus EW1701BM650060 100 250 0 ... 90 M-Bus EW1701BM7300

100 125 250 0 ... 90 M-Bus EW1701BM8100

Cable length 2m EWA630061

Cable length 10m EWA630064

For EW1700BM and EW1701BM EW9100AEZ001

For EW1700AA and EW1701AA, only in combination with reed switch EWA630061 or EWA630064

EW9100AGZ001

For EW1700AA and EW1701AA, only in combination with reed switch EWA630061 or EWA630064

EW535M0056

For EW1700BM and EW1701BM EWA3001799

Page 377: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-8

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.

EW447-449 Mechanical Heat Meters for energy metering of heating systems

EW447-452 Series Mechanical Hydronic Meters

Approvals • EW447/448/450/451: MID• EW449/452: EN1434

Features • Can be used for heating (EW447-449), cooling or both (EW450-452)

• No calming leg required on inlet or outlet• Optional remote readout via M-bus, pulse or RF

Medium type water

Measuring method multi jet

Display functions LCD, 7-digit

Power source Standard: 3V lithium battery (12 year lifetime)

Media temp. 5 ... 90 oC

Max. operating pressure 16 bar

Medium Nominal flow Dynamic range DN size Length Connection Interface Typem3/h mm mm

heating water 0,6 1:100 15 110 G 3/4 B none EW447A0100heating water 1,5 1:100 15 110 G 3/4 B none EW447A1200heating water 2,5 1:100 20 130 G 1 B none EW447A2000heating water 3,5 1:50 25 260 G 1 1/4 B none EW448A2800heating water 6 1:100 25 260 G 1 1/4 B none EW448A3600heating water 10 1:100 40 300 G 2 B none EW448A4600heating water 15 1:50 50 270 Flanges PN16 none EW449A5100heating water 25 1:50 65 300 Flanges PN16 none EW449A5900heating water 40 1:50 80 300 Flanges PN16 none EW449A6900heating water 60 1:50 100 360 Flanges PN16 none EW449A7700heating water 1,5 1:100 15 110 G 3/4 B Radio (RF) EW447F1200heating water 0,6 1:100 15 110 G 3/4 B M-Bus EW447M0100heating water 1,5 1:100 15 110 G 3/4 B M-Bus EW447M1200heating water 2,5 1:100 20 130 G 1 B M-Bus EW447M2000heating water 3,5 1:50 25 260 G 1 1/4 B M-Bus EW448M2800heating water 6 1:100 25 260 G 1 1/4 B M-Bus EW448M3600heating water 10 1:100 40 300 G 2 B M-Bus EW448M4600heating water 15 1:50 50 270 Flanges PN16 M-Bus EW449M5100heating water 25 1:50 65 300 Flanges PN16 M-Bus EW449M5900heating water 40 1:50 80 300 Flanges PN16 M-Bus EW449M6900heating water 60 1:50 100 360 Flanges PN16 M-Bus EW449M7700heating water 0,6 1:100 15 110 G 3/4 B pulse EW447P0100heating water 1,5 1:100 15 110 G 3/4 B pulse EW447P1200heating water 2,5 1:100 20 130 G 1 B pulse EW447P2000heating water 3,5 1:50 25 260 G 1 1/4 B pulse EW448P2800heating water 6 1:100 25 260 G 1 1/4 B pulse EW448P3600heating water 10 1:100 40 300 G 2 B pulse EW448P4600heating water 15 1:50 50 270 Flanges PN16 pulse EW449P5100heating water 25 1:50 65 300 Flanges PN16 pulse EW449P5900heating water 40 1:50 80 300 Flanges PN16 pulse EW449P6900heating water 60 1:50 100 360 Flanges PN16 pulse EW449P7700

Page 378: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-9

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

EW450-452 Mechanical Heat Meters for energy metering of cooling and combined cooling and heating systems

Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

Sanpress red bronze crimp fitting with sealing

Mapress stainless steel crimp fitting with sealing

Medium Nominal flow Dynamic range DN size Length Connection Interface Typem3/h mm mm

heating or chilled water 0,6 1:100 15 110 G 3/4 B none EW450A0100heating or chilled water 1,5 1:100 15 110 G 3/4 B none EW450A1200heating or chilled water 2,5 1:100 20 130 G 1 B none EW450A2000heating or chilled water 3,5 1:50 25 260 G 1 1/4 B none EW451A2800heating or chilled water 6 1:100 25 260 G 1 1/4 B none EW451A3600heating or chilled water 10 1:100 40 300 G 2 B none EW451A4600heating or chilled water 15 1:50 50 270 Flanges PN16 none EW452A5100heating or chilled water 25 1:50 65 300 Flanges PN16 none EW452A5900heating or chilled water 40 1:50 80 300 Flanges PN16 none EW452A6900heating or chilled water 60 1:50 100 360 Flanges PN16 none EW452A7700heating or chilled water 1,5 1:100 15 110 G 3/4 B Radio (RF) EW450F1200heating or chilled water 0,6 1:100 15 110 G 3/4 B M-Bus EW450M0100heating or chilled water 1,5 1:100 15 110 G 3/4 B M-Bus EW450M1200heating or chilled water 2,5 1:100 20 130 G 1 B M-Bus EW450M2000heating or chilled water 3,5 1:50 25 260 G 1 1/4 B M-Bus EW451M2800heating or chilled water 6 1:100 25 260 G 1 1/4 B M-Bus EW451M3600heating or chilled water 10 1:100 40 300 G 2 B M-Bus EW451M4600heating or chilled water 15 1:50 50 270 Flanges PN16 M-Bus EW452M5100heating or chilled water 25 1:50 65 300 Flanges PN16 M-Bus EW452M5900heating or chilled water 40 1:50 80 300 Flanges PN16 M-Bus EW452M6900heating or chilled water 60 1:50 100 360 Flanges PN16 M-Bus EW452M7700heating or chilled water 0,6 1:100 15 110 G 3/4 B pulse EW450P0100heating or chilled water 1,5 1:100 15 110 G 3/4 B pulse EW450P1200heating or chilled water 2,5 1:100 20 130 G 1 B pulse EW450P2000heating or chilled water 3,5 1:50 25 260 G 1 1/4 B pulse EW451P2800heating or chilled water 6 1:100 25 260 G 1 1/4 B pulse EW451P3600heating or chilled water 10 1:100 40 300 G 2 B pulse EW451P4600heating or chilled water 15 1:50 50 270 Flanges PN16 pulse EW452P5100heating or chilled water 25 1:50 65 300 Flanges PN16 pulse EW452P5900heating or chilled water 40 1:50 80 300 Flanges PN16 pulse EW452P6900heating or chilled water 60 1:50 100 360 Flanges PN16 pulse EW452P7700

For DN15, thread 1/2" EWA1500035

For DN20, thread 3/4" EWA1500042

For DN25, thread 1" EWA1500062

For DN40, thread 1 1/2" EWA1500072

DN15, for 15 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7404A015

DN15, for 18 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7404A018

DN20, for 22 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7404A020

DN25, for 28 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7404A025

DN15, for 15 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7403A015

DN15, for 18 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7403A018

DN20, for 22 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7403A020

DN25, for 28 mm pipe-diameter (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7403A025

Page 379: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-10

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Union nut, sealing and internally threaded red bronze tailpiece

Ballvalve with connection for supply temperature probe

Tailpiece for connection of supply temperature sensor

Brass immersion pockets (MID approved)

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.

DN15 (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7405A015

DN18 (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7405A018

DN20 (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7405A020

DN25 (includes 1 union nut, 1 tailpiece and 1 sealing ring) VA7405A025

G1/2" internal threads EWA087HY004

G3/4" internal threads EWA087HY005

G1" internal threads EWA087HY006

R1/2" external thread, M10x1 sensor thread EWA087HY003

G1/4" external thread, M10x1 sensor thread EWA354830

35mm, for DN15...32 EWA3002684

52mm, for DN40...65 EWA3002685

85mm, for DN80...125 EWA3004406

EW773 Series Ultrasonic Hydronic Meters DN15-100

Approvals • Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2

• Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)

Features • Improved power efficiency• High long term stability, tested and verified by independent

AGFW test• Insensitive to dirt• Versatile power supply• Optionally with integrated RF, Open Metering Standard,

868MHz• Individual remote reading (AMR) with add on plug & play

modules

Medium type water

Measuring method ultrasonic

Display functions LCD, 8-digit

Power source • Standard: 3.6V A-cell lithium battery (11 year lifetime)• Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac

or 24Vac mains unit

Dynamic range 1:250

Page 380: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-11

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

EW7730A Ultrasonic hydronic meter for heating applications

EW7730F Ultrasonic hydronic meter for heating applications, with RF on board

EW7730M Ultrasonic hydronic meter for heating applications, with M-Bus module

EW7730K Ultrasonic hydronic meter for heating applications; with M-Bus and pulse input modules

EW7731A Ultrasonic hydronic meter for heating and cooling applications

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating water 1,5 5 ... 130 15 110 G 3/4 B 16 none (retrofittable) none (retrofittable) EW7730A1200heating water 1,5 5 ... 130 20 130 G 1 B 16 none (retrofittable) none (retrofittable) EW7730A1400heating water 2,5 5 ... 130 20 130 G 1 B 16 none (retrofittable) none (retrofittable) EW7730A2000heating water 6 5 ... 150 25 260 G 1 1/4 B 16 none (retrofittable) none (retrofittable) EW7730A3600heating water 6 5 ... 150 32 260 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A4000heating water 10 5 ... 150 40 300 G 2 B 16 none (retrofittable) none (retrofittable) EW7730A4600heating water 10 5 ... 150 40 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A4800heating water 15 5 ... 150 50 270 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A5200heating water 25 5 ... 150 65 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A6000heating water 40 5 ... 150 80 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A7000heating water 60 5 ... 150 100 360 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7730A7800

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating water 1,5 5 ... 130 15 110 G 3/4 B 16 Radio (RF) none (retrofittable) EW7730F1200heating water 2,5 5 ... 130 20 130 G 1 B 16 Radio (RF) none (retrofittable) EW7730F2000

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating water 1,5 5 ... 130 15 110 G 3/4 B 16 M-Bus none (retrofittable) EW7730M1200heating water 2,5 5 ... 130 20 130 G 1 B 16 M-Bus none (retrofittable) EW7730M2000heating water 6 5 ... 150 25 260 G 1 1/4 B 16 M-Bus none (retrofittable) EW7730M3600

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating water 1,5 5 ... 130 15 110 G 3/4 B 16 M-Bus pulse input (2) EW7730K1200heating water 2,5 5 ... 130 20 130 G 1 B 16 M-Bus pulse input (2) EW7730K2000

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating or chilled water 1,5 5 ... 105 15 110 G 3/4 B 16 none (retrofittable) none (retrofittable) EW7731A1200heating or chilled water 2,5 5 ... 105 20 130 G 1 B 16 none (retrofittable) none (retrofittable) EW7731A2000heating or chilled water 6 5 ... 105 25 260 G 1 1/4 B 16 none (retrofittable) none (retrofittable) EW7731A3600heating or chilled water 6 5 ... 105 32 260 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A4000heating or chilled water 10 5 ... 105 40 300 G 2 B 16 none (retrofittable) none (retrofittable) EW7731A4600heating or chilled water 10 5 ... 105 40 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A4800heating or chilled water 15 5 ... 105 50 270 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A5200heating or chilled water 25 5 ... 105 65 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A6000heating or chilled water 40 5 ... 105 80 300 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A7000heating or chilled water 60 5 ... 105 100 360 Flanges PN25 25 none (retrofittable) none (retrofittable) EW7731A7800

Page 381: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-12

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16 EW7731F Ultrasonic hydronic meter for heating and cooling applications; with RF and two pulse inputs

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module

Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

Set of union nut, sealing and Sanpress red bronze crimp fitting (two packs per meter required)

Set of union nut, sealing and Mapress stainless steel crimp fitting (two packs per meter required)

Set of union nut, sealing and internally threaded red bronze tailpiece (two packs per meter required)

Temperature sensor installation kit (bulk pack of 20pcs)

Ballvalve with connection for supply temperature probe

Tailpiece for connection of supply temperature sensor

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating or chilled water 1,5 5 ... 105 15 110 G 3/4 B 16 Radio (RF) none (retrofittable) EW7731F1200heating or chilled water 2,5 5 ... 105 20 130 G 1 B 16 Radio (RF) none (retrofittable) EW7731F2000

Medium Nominalflow

Mediatemp.

DN size Length Connection Max. operatingpressure

Interface Function Type

m3/h oC mm mm bar

heating or chilled water 1,5 5 ... 105 15 110 G 3/4 B 16 M-Bus none (retrofittable) EW7731M1200heating or chilled water 2,5 5 ... 105 20 130 G 1 B 16 M-Bus none (retrofittable) EW7731M2000heating or chilled water 6 5 ... 105 25 260 G 1 1/4 B 16 M-Bus none (retrofittable) EW7731M3600heating or chilled water 6 5 ... 105 32 260 Flanges PN25 25 M-Bus none (retrofittable) EW7731M4000heating or chilled water 10 5 ... 105 40 300 Flanges PN25 25 M-Bus none (retrofittable) EW7731M4800heating or chilled water 15 5 ... 105 50 270 Flanges PN25 25 M-Bus none (retrofittable) EW7731M5200heating or chilled water 25 5 ... 105 65 300 Flanges PN25 25 M-Bus none (retrofittable) EW7731M6000heating or chilled water 40 5 ... 105 80 300 Flanges PN25 25 M-Bus none (retrofittable) EW7731M7000heating or chilled water 60 5 ... 105 100 360 Flanges PN25 25 M-Bus none (retrofittable) EW7731M7800

For DN15, thread 1/2" EWA1500035

For DN20, thread 3/4" EWA1500042

For DN25, thread 1" EWA1500062

For DN25, thread 1 1/2" EWA1500072

For DN15, for 15 mm pipe-diameter VA7404A015

For DN15, for 18 mm pipe-diameter VA7404A018

For DN20, for 22 mm pipe-diameter VA7404A020

For DN25, for 28 mm pipe-diameter VA7404A025

For DN15, for 15 mm pipe-diameter VA7403A015

For DN15, for 18 mm pipe-diameter VA7403A018

For DN20, for 22 mm pipe-diameter VA7403A020

For DN25, for 28 mm pipe-diameter VA7403A025

For DN15, thread Rp1/2" VA7405A015

For DN20, thread Rp3/4" VA7405A020

For DN25, thread Rp1" VA7405A025

Brass, max. 130C EWA3001303

Plastic, max. 90C EWA3001305

DN15, G1/2" internal threads EWA087HY004

DN20, G3/4" internal threads EWA087HY005

DN25, G1" internal threads EWA087HY006

R1/2" external thread, M10x1 sensor thread EWA087HY003

G1/4" external thread, M10x1 sensor thread EWA354830

Page 382: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-13

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

Brass immersion pockets (MID approved)

Modules

Power supply

Calculator mounts

Bluetooth optohead

IzarSet Expert dongle

Calibration certificates

Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

35mm, for DN15...32 EWA3002684

52mm, for DN40...65 EWA3002685

85mm, for DN80...125 EWA3004406

M-Bus communication module (single pack) EWA3022071

M-Bus communication module (bulk pack of 72pcs) EWA3023125

Pulse output module with two outputs EWA3022073

Pulse input module with two inputs (single pack) EWA3022074

Pulse input module with two inputs (bulk pack of 72pcs) EWA3023130

Combined pulse input/output module EWA3022075

RS232 interface module with cable EWA3028129

RS485 interface module EWA3022101

Analogue 4...20mA module (occupies both slots) EWA3022106

A-cell battery 3.6V DC (11 year lifetime) as replacement for standard battery EWA3022102

D-cell battery 3.6V DC (16 year lifetime) EWA3022103

Mains supply unit 230V AC EWA3022076

Mains supply unit 24V AC EWA3022079

Replacement backup battery for mains supply units EWA3022097

Wall mount (single pack) EWA3007090

Wall mount (bulk pack of 20pcs) EWA3007091

Angle mount 105 EWA3026160

Distance mount EWA54300011

DIN rail mount EWA54300012

For all EW773 EWA3001799

For all EW773 EWP3021322

For up to five meters EWA3003095A

For six to 20 meters EWA3003095B

For more than 20 meters EWA3003095C

C-cell battery 3.0V DC (12 year lifetime) as replacement for standard battery EWA54200006

D-cell battery 3.6V DC (16 year lifetime) EWA3000783

M-Bus communication module (for EW773xA types) EWA54200001

Pulse output module (2 outputs) EWA54200002

Pulse input module (2 inputs) EWA54200003

RF module EWA54200017

Combined pulse input/output module EWA54200026

RS232 interface module EWA54200030

Page 383: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-14

Hydronic Meters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Honeywell EW457 Series mechanical flowmeters are used for flow measurement of heating water in hydronic heating systems.They are typically used with an EW545 Series energy calculator. The combination of flowmeter and energy calculator has the same functionality as a heatmeter. EW457 Series flowmeters are equipped with a reed switch for pulse output to a calculator.

EW457 Mechanical Flowmeters

Approvals • EN1434 approval (DN50, DN65, DN80, DN150 and DN200)• National approval (DN100 and DN125)

Features • Installation in any position• Very low pressure loss• Rugged design for longterm accuracy• Completely dry running design

Medium type water

Measuring method woltmann wheel

Display functions Mechanical counter

Medium heating water

Media temp. 0 ... 120 oC

Connection Flanges PN16

Max. operating pressure 16 bar

Interface pulse

Nominal flow DN size Length Typem3/h mm mm

15 50 200 EW457P500025 65 200 EW457P560032 80 200 EW457P620060 100 250 EW457P7300

100 125 250 EW457P8100200 150 300 EW457P8503250 200 350 EW457P8900400 250 450 EW457P9100600 300 500 EW457P9203

Page 384: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-15

Hydronic Meters

16

17

18

19

20

21

22

24

23

25

26

27

28

Honeywell EW473 Series ultrasonic flowmeters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW545 Series energy calculator. The combination of flowmeter and energy calculator has the same functionality as a heatmeter. EW473 Series flowmeter are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).

EW473 Ultrasonic Flowmeters

Approvals MID

Features • No pressure loss• Rugged design• Indifferent to dirt in the system

Medium type water

Measuring method ultrasonic

Display functions LCD, 8+2-digit

Media temp. 2 ... 120 oC

Power source 230Vac, 50...60Hz

Medium heating or chilled water

Connection Flanges PN16

Max. operating pressure 16 bar

Interface pulse

Nominal flow DN size Length Typem3/h mm mm

120 100 350 EW473P8303200 125 350 EW473P8725300 150 500 EW473P9025500 200 500 EW473P9125800 250 600 EW473P9225

1120 300 500 EW473P93031500 350 550 EW473P94251900 400 600 EW473P95252950 500 625 EW473P96254300 600 750 EW473P9925

Page 385: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-16

Calculators and system components

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Calculators and system components

Electronic energy calculator consisting of electronic measurement unit and temperature sensors. For use in combination with an ultrasonic or mechanical volume measuring component.Metering of hydronic heating and / or cooling energy in hydronic systems based on volume, supply and return temperature. Suitable for energy metering of cooling, heating and combined cooling and heating systems.

Pair of Pt500 temperature sensors, 5.2mm (MID approved)

Temperature sensor installation kit (bulk pack of 20pcs)

Tailpiece for connection of supply temperature sensor

Brass immersion pockets (MID approved)

EW545 Series Energy Calculators

Approvals MID

Features • Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)

• High long term stability, tested and verified by independent AGFW test

• Versatile power supply• On request with integrated radio• Individual remote reading (AMR) with add on plug & play

modules• Extensive readable data memory• Two communicaton ports

Medium type water

Display functions LCD, 8-digit

Power source A-cell lithium battery 3.6V DC (11 year lifetime), other on request, see Accessories below

Interface none (retrofittable)

Function none (retrofittable)

Product description Type10 litres / pulse; energy unit: MWh with 3 decimal places EW5451A0100100 litres / pulse; energy unit: MWh with 2 decimal places EW5451A4100250 litres / pulse; energy unit: MWh with 1 decimal place EW5451A72001,000 litres / pulse; energy unit: MWh with 1 decimal place EW5451A91002.5 litres / pulse; energy unit: MWh with 1 decimal place EW5451A830350 litres / pulse; energy unit: MWh with 1 decimal place EW5451A9303

Cable length 2m EWA3002680

Cable length 3m EWA3002681

Cable length 5m EWA3002682

Cable length 10m EWA3002679

Brass, max. 130C EWA3001303

Plastic, max. 90C EWA3001305

R1/2 external thread, M10 x 1 sensor thread EWA087HY003

35mm, for DN25...32 EWA3002684

52mm, for DN40...65 EWA3002685

85mm, for DN80...125 EWA3004406

120mm, for DN150 EWA3004407

Page 386: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-17

Calculators and system components

16

17

18

19

20

21

22

24

23

25

26

27

28

Ballvalves with connection for supply temperature sensor

Modules

Power supply

Calculator mounts

Bluetooth optohead

IzarSet Expert dongle

Calibration certificates

G 1/2" internal thread EWA087HY004

G 3/4" internal thread EWA087HY005

G 1" internal thread EWA087HY006

M-Bus communication module (single pack) EWA3022071

M-Bus communication module (bulk pack of 72pcs) EWA3023125

Pulse output module with two outputs EWA3022073

Pulse input module with two inputs (single pack) EWA3022074

Pulse input module with two inputs (bulk pack of 72pcs) EWA3023130

Combined pulse input/output module EWA3022075

RS232 interface module with cable EWA3028129

RS485 interface module EWA3022101

Analogue 4...20mA module (occupies both slots) EWA3022106

A-cell battery 3.6V DC (11 year lifetime) as replacement for standard battery EWA3022102

D-cell battery 3.6V DC (16 year lifetime) EWA3022103

Mains supply unit 230V AC EWA3022076

Mains supply unit 24V AC EWA3022079

Replacement backup battery for mains supply units EWA3022097

Wall mount (single pack) EWA3007090

Wall mount (bulk pack of 20pcs) EWA3007091

Angle mount 105 EWA3026160

Distance mount EWA54200011

DIN rail mount EWA54200012

For all EW545 EWA3001799

For all EW545 EWP3021322

For up to five meters EWA3003095A

For six to 20 meters EWA3003095B

For more than 20 meters EWA3003095C

Page 387: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

17-18

Calculators and system components

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16EW535 Series M-Bus System Components enable remote recording and reading out of M-Bus capable meters, e.g. Honeywell EW773 Series Ultrasonic Heat Meters.The M-Bus system is used to connect various meters, typically M-Bus capable heat meters and water meters but also gas or electricity meters to a central M-Bus master unit. Values recorded by the meter are stored in the master unit and can be read out directly by connecting a PC or remotely, e.g. by telephone line or LAN converter.Many non M-Bus capable meters can be connected to the M-Bus system by using a converter.

EW535

Receiver for stationary readout of suitable hydronic meters with RF capability and conversion into M-Bus signal. Remote readout and data logging is done in combination with an IzarCenter M-Bus master or repeater. Configuration is also done via the IzarCenter.

EW535 Series M-Bus System Components

Materials Housing made of grey heat resistant plastic

Ambient temperature -20 ... 70 oC

Maximum humidity 90 %rh

Model name Product description TypeIzarCenter 60 M-Bus level converter/repeater for max. 60 M-Bus devices EW535M5777

IzarCenter 60 Memory M-Bus master for max. 60 M-Bus devices, 256MB data logger memory EW535M5781IzarCenter 120 M-Bus level converter/repeater for max. 120 M-Bus devices, 256MB data logger memory EW535M5778

IzarCenter 120 Memory M-Bus master for max. 120 M-Bus devices, 256MB data logger memory EW535M5782IzarCenter 250 M-Bus level converter/repeater for max. 250 M-Bus devices EW535M5780

IzarCenter 250 Memory M-Bus master for max. 250 M-Bus devices, 256MB data logger memory EW535M5783Hydro-Port Pulse Pulse meter to M-Bus converter, 2 pulse inputs EW535M0056

Hydro-Port Analog Converter for meters with analogue 420mA output to M-Bus, 2 analogue inputs,1 analogue output, 1 input for PT temperature sensor

EW535M0057

Hydro-Port Housing Heavy-duty housing IP66 for Hydro-Port modules EW535M0058Hydro-Port Control M-Bus relay module with 2 digital state inputs and 2 bistable relay outputs EW535M0059

EW535M0131 M-Bus RF Receiver

Features • No wiring from meter to master necessary• Powered through M-Bus interface no external power source

required• Two wire M-Bus interface for direct connection to MBus

master• Internal memory to buffer last radio telegram of up to 450

meters

Interface M-Bus

TypeEW535M0131

Page 388: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure Reducing Valves, Pressure Regulators, residential/industrial Page

Pressure Reducing Valves 18-2Pressure Reducing Valves with flanges 18-17Pressure Regulators with flanges 18-24

Page 389: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-2

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure Reducing Valves

D03 pressure reducing valves protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Internal threads on both sides

Inlet with external thread, outlet with threaded male connection

Standard pattern pressure reducing valve, D03

Medium type water

Max. operating temp. 40C (DIN EN1567)

Body material brass

Spring bonnet material brass

Body finishing nickel plated

Pressure rating PN10

Flow capacity Kvs 1,73

Pressure setpoint range 1,5 ... 6 bar

Balanced seat design yes

Additional description • Good value and simple construction• Outlet pressure adjustable adjustment screw• The adjustment spring is not in contact with the potable water• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure • Meets ACS recommendations

Connection Inlet/Outlet Port diameter DN size Typeinch mm

internal thread 1/2 15 D03-1/2Cinternal thread 3/4 20 D03-3/4C

Connection Inlet/Outlet Port diameter DN size Typeinch mm

IN:ext.thread; OUT:conn.set,ext.thread 3/4 20 D03-3/4ZA

Page 390: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-3

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Standard pattern

Accessories

Spare parts

Standard pattern pressure reducing valve, D04FS

Medium type water

Max. operating temp. 40C (DIN EN 1567); 70C (max. press. 10bar); WRC approved until 23C

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Connection Inlet/Outlet external thread

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Additional description • Compact construction• The adjustment spring is not in contact with the potable water• Outlet pressure adjustable with green adjustment knob• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure

Port diameter DN size Flow capacity Kvs Typeinch mm

3/8 10 2,5 D04FS-3/8A1/2 15 2,7 D04FS-1/2A3/4 20 2,9 D04FS-3/4A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 4 bar

M38K-A4

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar

M38K-A10

Valve insert complete D04FSA-1/2

Blanking plug with O-ring R1/4"(5 pcs.) S06K-1/4

Page 391: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-4

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Standard pattern with threaded male connections

Standard pattern without fittings

Accessories

Spare Parts

Standard pattern pressure reducing valve, D05F

Approvals DVGW-approved for connection sizes 1/2" - 1"

Medium type water

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Max. operating temp. 40C (DIN EN 1567); 70C (max. press. 10bar)

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Pressure rating PN25

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Additional description • The outlet pressure is set by turning the adjustment knob• The set pressure is directly indicated on the set point scale• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully exchanged• Integral fine filter

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

conn. set, ext. thread 1/2 15 2,6 D05F-1/2Aconn. set, ext. thread 3/4 20 2,8 D05F-3/4Aconn. set, ext. thread 1 25 3 D05F-1A

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

external thread 1/2 15 2,6 D05F-1/2Eexternal thread 3/4 20 2,8 D05F-3/4Eexternal thread 1 25 3 D05F-1E

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections _VST06-A

Connection set with solder connections _VST06-B

Spring bonnet complete with setting scale for sizes R 1/2 - R 1 0901515

Valve insert complete (without filter) for sizes R 1/2 - R 1 D05FA-1/2B

Replacement filter insert for sizes R 1/2 + R 1 ES05F-1/2A

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Page 392: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-5

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification.By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation..

Standard pattern with threaded male connections

Standard pattern without fittings

Standard pattern pressure reducing valve, D05FS

Approvals • DIN/DVGW approved

Medium type water

Media Water, compressed air* and nitrogen* in consideration of valid standards (e.g. DIN EN 12502) (* As part of an installation being approved according to PED requirements, this product must also be certified)

Max. operating temp. 40C (DIN EN 1567); 70C (max. press. 10bar)

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Pressure rating PN25

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Additional description • The outlet pressure is set by turning the adjustment knob• The set pressure is directly indicated on the set point scale• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully exchanged• Integral fine filter• Also available without fittings• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure• Light weight

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

conn. set, ext. thread 1/2 15 3 D05FS-1/2Aconn. set, ext. thread 3/4 20 3,5 D05FS-3/4Aconn. set, ext. thread 1 25 3,7 D05FS-1Aconn. set, ext. thread 1 1/4 32 7,3 D05FS-11/4Aconn. set, ext. thread 1 1/2 40 7,5 D05FS-11/2Aconn. set, ext. thread 2 50 7,7 D05FS-2A

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

external thread 1/2 15 3 D05FS-1/2Eexternal thread 3/4 20 3,5 D05FS-3/4Eexternal thread 1 25 3,7 D05FS-1Eexternal thread 1 1/4 32 7,3 D05FS-11/4Eexternal thread 1 1/2 40 7,5 D05FS-11/2Eexternal thread 2 50 7,7 D05FS-2E

Page 393: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-6

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Accessories

Spare Parts

Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Pressure gauge with housing diameter 50 mm, below connection thread G 1/4, range 0 - 4 bar

M38K-A4

Pressure gauge with housing diameter 50 mm, below connection thread G 1/4, range 0 - 10 bar

M38K-A10

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Insulation shells for nominal size 1/2" DS05-1/2

Insulation shells for nominal size 3/4" DS05-3/4

Insulation shells for nominal size 1" DS05-1

Insulation shells for nominal size 11/4" DS05-11/4

Insulation shells for nominal size 11/2" DS05-11/2

Insulation shells for nominal size 2" DS05-2

Connection set with threaded connections _VST06-A

Connection set with solder connections _VST06-B

Spring bonnet complete with setting scale for sizes R 1/2 - R 1 0901515

Spring bonnet complete with setting scale for sizes R 11/4 - R 2 0903890

Valve insert complete (without filter) for sizes R 1/2 - R 1 D05FA-1/2B

Valve insert complete (without filter) for sizes R 11/4 - R 2 D05FA-11/4B

Replacement filter insert for sizes R 1/2 - R 2 ESD05FS

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Standard pattern pressure reducing valve, D05FT

Approvals • DIN/DVGW-certified

Medium type water

Max. operating temp. 80C (DIN EN1567); 95C (short, soft water)

Body material brass, dezincification resistant

Spring bonnet material brass

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Additional description • Suitable for hot water systems• The outlet pressure is set by turning the adjustment knob• The set pressure is directly indicated on the set point scale• The adjustment spring is not in contact with the potable water• The valve insert is made of dezincification resistant brass and

can be fully exchanged • Also available without fittings• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure• Light weight

Page 394: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-7

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Standard pattern with threaded male connections

Standard pattern without fittings

Accessories

Spare Parts

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

conn. set, ext. thread 1/2 15 3 D05FT-1/2Aconn. set, ext. thread 3/4 20 3,5 D05FT-3/4Aconn. set, ext. thread 1 25 3,7 D05FT-1Aconn. set, ext. thread 1 1/4 32 7,3 D05FT-11/4Aconn. set, ext. thread 1 1/2 40 7,5 D05FT-11/2Aconn. set, ext. thread 2 50 7,7 D05FT-2A

Connection Inlet/Outlet Port diameter DN size Flow capacity Kvs Typeinch mm

external thread 1/2 15 3 D05FT-1/2Eexternal thread 3/4 20 3,5 D05FT-3/4Eexternal thread 1 25 3,7 D05FT-1Eexternal thread 1 1/4 32 7,3 D05FT-11/4Eexternal thread 1 1/2 40 7,5 D05FT-11/2Eexternal thread 2 50 7,7 D05FT-2E

Pressure gauge with housing diameter 50 mm, below connection thread G 1/4", range 0 - 10 bar

M38T-A10

Insulation shells for nominal size 1/2 DS05-1/2

Insulation shells for nominal size 3/4 DS05-3/4

Insulation shells for nominal size 1 DS05-1

Insulation shells for nominal size 11/4 DS05-11/4

Insulation shells for nominal size 11/2 DS05-11/2

Insulation shells for nominal size 2 DS05-2

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections _VST06-A

Connection set with solder connections _VST06-B

Spring bonnet complete with setting scale for sizes R 1/2" - R 1" 0903919

Spring bonnet complete with setting scale for sizes R 11/4" - R 2" 0903920

Valve insert complete (without filter) for sizes R 1/2" - R 1" D05FA-1/2T

Valve insert complete (without filter) for sizes R 11/4" - R 2" D05FA-11/4T

Replacement filter insert for sizes R 1/2" - R 2" ESD05FS

Hexagon-plug with copper sealing-ring R1/4" (5 pcs.) S06M-1/4

Page 395: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-8

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With threaded male connections, clear filter bowl

With threaded male connections, brass filter bowl

Pressure reducing valve with balanced seat and set point scale, standard pattern

Approvals • DVGW-certified• WRAS approved according to BSEN1567• Up to size 1 1/4" approved for low noise, Group 1 without

limitations

Medium type water

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Filter mesh 0,16 mm

Setpoint scale yes

Balanced seat design yes

Pressure setpoint range 1,5 ... 6 bar

Additional description • Outlet pressure preset to 3 bar • The outlet pressure is set by turning the adjustment knob• The set pressure is directly indicated on the set point scale• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully exchanged• Easily retrofittable to convert valve to a reverse-rinsing filter

combination• Can be retrofitted with an inlet non-return valve• In applications where UV radiation and solvent vapours are

present, use the SM06T brass filter bowl!

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

conn. set, ext. thread 1/2 15 PN16 2,4 clear 40C D06F-1/2Aconn. set, ext. thread 3/4 20 PN16 3,1 clear 40C D06F-3/4Aconn. set, ext. thread 1 25 PN16 5,8 clear 40C D06F-1Aconn. set, ext. thread 1 1/4 32 PN16 5,9 clear 40C D06F-11/4Aconn. set, ext. thread 1 1/2 40 PN16 12,6 clear 40C D06F-11/2Aconn. set, ext. thread 2 50 PN16 12 clear 40C D06F-2A

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

conn. set, ext. thread 1/2 15 PN25 2,4 brass 60C; 70C(max. press.10bar)

D06F-1/2B

conn. set, ext. thread 3/4 20 PN25 3,1 brass 60C; 70C(max. press.10bar)

D06F-3/4B

conn. set, ext. thread 1 25 PN25 5,8 brass 60C; 70C(max. press.10bar)

D06F-1B

conn. set, ext. thread 1 1/4 32 PN25 5,9 brass 60C; 70C(max. press.10bar)

D06F-11/4B

conn. set, ext. thread 1 1/2 40 PN25 12,6 brass 60C; 70C(max. press.10bar)

D06F-11/2B

conn. set, ext. thread 2 50 PN25 12 brass 60C; 70C(max. press.10bar)

D06F-2B

Page 396: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-9

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Without fittings, clear filter bowl, DN is based on connection size of tailpiece

Accessories

Spare Parts

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

external thread 1/2 15 PN16 2,4 clear 40C D06F-1/2Eexternal thread 3/4 20 PN16 3,1 clear 40C D06F-3/4Eexternal thread 1 25 PN16 5,8 clear 40C D06F-1Eexternal thread 1 1/4 32 PN16 5,9 clear 40C D06F-11/4Eexternal thread 1 1/2 40 PN16 12,6 clear 40C D06F-11/2Eexternal thread 2 50 PN16 12 clear 40C D06F-2E

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections for connection sizes R 1/2 VST06-1/2A

Connection set with threaded connections for connection sizes R 3/4 VST06-3/4A

Connection set with threaded connections for connection sizes R 1 VST06-1A

Connection set with threaded connections for connection sizes R 11/4 VST06-11/4A

Connection set with threaded connections for connection sizes R 11/2 VST06-11/2A

Connection set with threaded connections for connection sizes R 2 VST06-2A

Connection set with solder connections for connection sizes R 1/2 VST06-1/2B

Connection set with solder connections for connection sizes R 3/4 VST06-3/4B

Connection set with solder connections for connection sizes R 1 VST06-1B

Connection set with solder connections for connection sizes R 11/4 VST06-11/4B

Connection set with solder connectionsfor connection sizes R 11/2 VST06-11/2B

Connection set with solder connections for connection sizes R 2 VST06-2B

Reverse-rinsing filter for retro-conversion to a filter combination unit of pressure reducing valves

_FN09S

Inlet non-return valve for connection sizes R 3/4 - R 2 _RV277

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FA-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FA-1B

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FA-11/2

Replacement filter insert for sizes R 1/2 + R 3/4 ES06F-1/2A

Replacement filter insert for sizes R 1 + R 1 1/4 ES06F-1B

Replacement filter insert for sizes R 1 1/2 + R 1 1/4 ES06F-11/2A

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Brass filter bowl with O-ring for sizes R 1/2 + R 3/4 SM06T-1/2

Brass filter bowl with O-ring for sizes R 1 + R 1 1/4 SM06T-1B

Brass filter bowl with O-ring for sizes R 1 1/2 + R 2 SM06T-11/2

Clear filter bowl with O-ring for sizes R 1/2 + R 3/4 SK06T-1/2

Clear filter bowl with O-ring for sizes R 1 + R 1 1/4 SK06T-1B

Clear filter bowl with O-ring for sizes R 1 1/2 + R 2 SK06T-11/2

Page 397: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-10

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect household water installations against excessive pressure from the supply. They can also be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With threaded male connections, clear filter bowl

With threaded male connections, stainless steel filter bowl

Stainless steel pressure reducing valve with setpoint scale, D06FI

Approvals DVGW certified• Up to size 11/4" approved for low noise, Group 1 without

limitations

Medium type water

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Body material stainless steel

Spring bonnet material synthetic material

Filter mesh 0,16 mm

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Additional description • Outlet pressure preset to 3 bar• The outlet pressure is set by turning the adjustment knob• The set pressure is directly indicated on the set point scale• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully exchanged• Integral fine filter• Also available without fittings• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure• Light weight• Meets KTW recommendations for potable water

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

conn. set, ext. thread 1/2 15 PN16 2,4 clear 40C D06FI-1/2Aconn. set, ext. thread 3/4 20 PN16 3,1 clear 40C D06FI-3/4Aconn. set, ext. thread 1 25 PN16 5,8 clear 40C D06FI-1Aconn. set, ext. thread 1 1/4 32 PN16 5,9 clear 40C D06FI-11/4Aconn. set, ext. thread 1 1/2 40 PN16 12,6 clear 40C D06FI-11/2Aconn. set, ext. thread 2 50 PN16 12 clear 40C D06FI-2A

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

conn. set, ext. thread 1/2 15 PN25 2,4 stainless steel 60C; 70C(max. press.10bar)

D06FI-1/2B

conn. set, ext. thread 3/4 20 PN25 3,1 stainless steel 60C; 70C(max. press.10bar)

D06FI-3/4B

conn. set, ext. thread 1 25 PN25 5,8 stainless steel 60C; 70C(max. press.10bar)

D06FI-1B

conn. set, ext. thread 1 1/4 32 PN25 5,9 stainless steel 60C; 70C(max. press.10bar)

D06FI-11/4B

conn. set, ext. thread 1 1/2 40 PN25 12,6 stainless steel 60C; 70C(max. press.10bar)

D06FI-11/2B

conn. set, ext. thread 2 50 PN25 12 stainless steel 60C; 70C(max. press.10bar)

D06FI-2B

Page 398: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-11

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Without fittings, clear filter bowl, DN is based on connection size of tailpiece

Accessories

Spare Parts

ConnectionInlet/Outlet

Portdiameter

DNsize

Pressurerating

Flow capacityKvs

Filterbowl

Max. operating temp. Type

inch mm

external thread 1/2 15 PN16 2,4 clear 40C D06FI-1/2Eexternal thread 3/4 20 PN16 3,1 clear 40C D06FI-3/4Eexternal thread 1 25 PN16 5,8 clear 40C D06FI-1Eexternal thread 1 1/4 32 PN16 5,9 clear 40C D06FI-11/4Eexternal thread 1 1/2 40 PN16 12,6 clear 40C D06FI-11/2Eexternal thread 2 50 PN16 12 clear 40C D06FI-2E

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections for connection sizes R 1/2 VST06I-1/2A

Connection set with threaded connections for connection sizes R 3/4 VST06I-3/4A

Connection set with threaded connections for connection sizes R 1 VST06I-1A

Connection set with threaded connections for connection sizes R 11/4 VST06I-11/4A

Connection set with threaded connections for connection sizes R 11/2 VST06I-11/2A

Connection set with threaded connections for connection sizes R 2 VST06I-2A

Connection set with solder connections for connection sizes R 1/2 VST06I-1/2B

Connection set with solder connections for connection sizes R 3/4 VST06I-3/4B

Connection set with solder connections for connection sizes R 1 VST06I-1B

Connection set with solder connections for connection sizes R 11/4 VST06I-11/4B

Connection set with solder connections for connection sizes R 11/2 VST06I-11/2B

Connection set with solder connections for connection sizes R 2 VST06I-2B

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FI-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FI-1

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FI-11/2

Replacement filter insert for sizes R 1/2 + R 3/4 ES06F-1/2A

Replacement filter insert for sizes R 1 + R 1 1/4 ES06F-1B

Replacement filter insert for sizes R 1 1/2 + R 1 1/4 ES06F-11/2A

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Clear filter bowl with O-ring for sizes R 1/2 + R 3/4 SK06T-1/2

Clear filter bowl with O-ring for sizes R 1 + R 1 1/4 SK06T-1B

Clear filter bowl with O-ring for sizes R 1 1/2 + R 2 SK06T-11/2

Stainless steel bowl with O-ring for sizes R 1/2 + R 3/4 SI06T-1/2

Stainless steel bowl with O-ring for sizes R 1 + R 1 1/4 SI06T-1

Stainless steel filter bowl with O-ring for sizes R 1 1/2 + R 2 SI06T-11/2

Page 399: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-12

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect nstallations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With threaded male connections, brass filter bowl

High pressure pattern pressure reducing valve, D06FH

Medium type water

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Max. operating temp. 60C; 70C (max. press.10bar)

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Connection Inlet/Outlet conn. set, ext. thread

Pressure rating PN25

Filter mesh 0,16 mm

Pressure setpoint range 1,5 ... 12 bar

Balanced seat design yes

Filter bowl brass

Additional description • Outlet Pressure preset to 5 bar• The outlet pressure is set by turning the adjustment knob• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully interchanged• Easily retrofittable to convert valve to a reverse-rinsing filter

combination• Can be retrofitted with an inlet non-return valve

Port diameter DN size Flow capacity Kvs Typeinch mm

1/2 15 2,4 D06FH-1/2B3/4 20 3,1 D06FH-3/4B

1 25 7,6 D06FH-1B1 1/4 32 9,1 D06FH-11/4B1 1/2 40 12,6 D06FH-11/2B

2 50 12 D06FH-2B

Page 400: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-13

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections for connection sizes R 1/2 VST06-1/2A

Connection set with threaded connections for connection sizes R 3/4 VST06-3/4A

Connection set with threaded connections for connection sizes R 1 VST06-1A

Connection set with threaded connections for connection sizes R 11/4 VST06-11/4A

Connection set with threaded connections for connection sizes R 11/2 VST06-11/2A

Connection set with threaded connections for connection sizes R 2 VST06-2A

Connection set with solder connections for connection sizes R 1/2 VST06-1/2B

Connection set with solder connections for connection sizes R 3/4 VST06-3/4B

Connection set with solder connections for connection sizes R 1 VST06-1B

Connection set with solder connections for connection sizes R 11/4 VST06-11/4B

Connection set with solder connections for connection sizes R 11/2 VST06-11/2B

Connection set with solder connections for connection sizes R 2 VST06-2B

Reverse-rinsing filter with red bronze filter cup. Reverse-rinsing filter for retro-conversion of a pressure reducing valves to a filter combination unit

_FN09S-AM

Inlet non-return valve for connection sizes R 3/4 - R 2 _RV277

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FA-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FA-1A

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FA-11/2

Replacement filter insert for sizes R 1/2 + R 3/4 ES06F-1/2A

Replacement filter insert for sizes R 1 + R 1 1/4 ES06F-1A

Replacement filter insert for sizes R 1 1/2 + R 1 1/4 ES06F-11/2A

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Brass filter bowl with O-ring for sizes R 1/2 + R 3/4 SM06T-1/2

Brass filter bowl with O-ring for sizes R 1 + R 1 1/4 SM06T-1B

Brass filter bowl with O-ring for sizes R 1 1/2 + R 2 SM06T-11/2

Page 401: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-14

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With threaded male connections, brass filter bowl

Low pressure pattern pressure reducing valve, D06FN

Medium type water

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Max. operating temp. 60C; 70C (max. press.10bar)

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Connection Inlet/Outlet conn. set, ext. thread

Pressure rating PN25

Filter mesh 0,16 mm

Pressure setpoint range 0,5 ... 2 bar

Balanced seat design yes

Filter bowl brass

Additional description • Outlet pressure preset to 1.5 bar• The outlet pressure is set by turning the adjustment knob• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully interchanged • Easily retrofittable to convert valve to a reverse-rinsing filter

combination• Can be retrofitted with an inlet non-return valve

Port diameter DN size Flow capacity Kvs Typeinch mm

1/2 15 2,4 D06FN-1/2B3/4 20 3,1 D06FN-3/4B

1 25 7,6 D06FN-1B1 1/4 32 9,1 D06FN-11/4B1 1/2 40 12,6 D06FN-11/2B

2 50 12 D06FN-2B

Page 402: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-15

Pressure Reducing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Connection set with threaded connections for connection sizes R 1/2 VST06-1/2A

Connection set with threaded connections for connection sizes R 3/4 VST06-3/4A

Connection set with threaded connections for connection sizes R 1 VST06-1A

Connection set with threaded connections for connection sizes R 11/4 VST06-11/4A

Connection set with threaded connections for connection sizes R 11/2 VST06-11/2A

Connection set with threaded connections for connection sizes R 2 VST06-2A

Connection set with solder connections for connection sizes R 1/2 VST06-1/2B

Connection set with solder connections for connection sizes R 3/4 VST06-3/4B

Connection set with solder connections for connection sizes R 1 VST06-1B

Connection set with solder connections for connection sizes R 11/4 VST06-11/4B

Connection set with solder connections for connection sizes R 11/2 VST06-11/2B

Connection set with solder connections for connection sizes R 2 VST06-2B

Reverse-rinsing filter with red bronze filter cup. Reverse-rinsing filter for retro-conversion of a pressure reducing valves to a filter combination unit

_FN09S-AM

Inlet non-return valve for connection sizes R 3/4 - R 2 _RV277

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FNA-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FNA-1

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FNA-11/2

Replacement filter insert for sizes R 1/2 + R 3/4 ES06F-1/2A

Replacement filter insert for sizes R 1 + R 1 1/4 ES06F-1A

Replacement filter insert for sizes R 1 1/2 + R 2 ES06F-11/2A

Synthetic blanking plug with O-ring (5 pcs) S06K-1/4

Brass filter bowl with O-ring for sizes R 1/2 + R 3/4 SM06T-1/2

Brass filter bowl with O-ring for sizes R 1 + R 1 1/4 SM06T-1B

Brass filter bowl with O-ring for sizes R 1 1/2 + R 2 SM06T-11/2

Page 403: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-16

Pressure Reducing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for industrial or commercial applications within the range of their specification. Because pressure reducing valves are subject to wear, they cannot be used as the only means of protection and if the downstream system needs to be protected against excessive pressure to prevent leakage, then a suitable safety valve must be fitted.

Normal pattern

Accessories

Standard pattern pressure reducing valve for compressed air, D22

Approvals Certified to Pressure Equipment Directive 97/23/EC, Reference No. CE 0035

Medium type air

Media Compressed air, non-toxic and non-flammable gases

Max. operating temp. 70C

Body material brass

Spring bonnet material synthetic material

Connection Inlet/Outlet internal thread

Pressure rating PN40

Pressure setpoint range 1 ... 10 bar

Balanced seat design yes

Additional description • Screw with knob for setting pressure• The adjustment spring is not in contact with the medium• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure• Compact construction• Short installed length• Light weight

Port diameter DN size Typeinch mm

1/4 8 D22-1/4A3/8 10 D22-3/8A1/2 15 D22-1/2A3/4 20 D22-3/4A

1 25 D22-1A1 1/4 32 D22-11/4A1 1/2 40 D22-11/2A

2 50 D22-2A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, 0 - 4 bar M38K-A4

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, 0 - 10 bar M38K-A10

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, 0 - 16 bar M38K-A16

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, 0 - 25 bar M38K-A25

Strainer With double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-3/8A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-1/2A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-3/4A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-1A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-11/4A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-11/2A

Strainer with double mesh strainer, brass housing A = Mesh size approx. 0.35 mm FY30-2A

Page 404: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-17

Pressure Reducing Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure Reducing Valves with flanges

Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 16 flanged connections

Spare Parts

Standard pattern pressure reducing valve with flanged connections, D15P

Medium type water/air

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Body material cast iron GG25

Spring bonnet material metal

Body finishing powder coating

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN16

Balanced seat design yes

Additional description • Non-rising stem for setting outlet pressure and position indicator on spring bonnet (except for DN 200 mm)

• The adjustment spring is not in contact with the potable water• With inlet and outlet pressure gauge (DN 50-DN 150) or with

outlet pressure gauge (DN 200)• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe

DN size Flow capacity Kvs Pressure setpoint range Typemm bar

50 28 1,5 ... 8 D15P-50A125 180 1,5 ... 8 D15P-125A150 250 1,5 ... 8 D15P-150A200 380 1,5 ... 6 D15P-200A

Pressure gauge (only for nominal size DN 200), 0 - 10 bar M07M-A10

Pressure gauge, 0 - 10 bar M39M-A10

Pressure gauge, 0 - 16 bar M39M-A16

Page 405: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-18

Pressure Reducing Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 16 flanged connections

Accessories

Low pressure pattern pressure reducing valve with flanged connections, D15NP

Medium type water/air

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Body material cast iron GG25

Spring bonnet material metal

Body finishing powder coating

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN16

Pressure setpoint range 0,2 ... 2 bar

Balanced seat design yes

Additional description • Non-rising stem for setting outlet pressure and position indicator on spring bonnet

• The adjustment spring is not in contact with the potable water• With inlet and outlet pressure gauge (DN 80 - DN 150) or with

outlet pressure gauge (DN 50, DN 65)• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe

DN size Flow capacity Kvs Typemm

50 28 D15NP-50A65 47 D15NP-65A80 70 D15NP-80A

100 110 D15NP-100A125 180 D15NP-125A150 250 D15NP-150A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN50

RV283P-50A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN65

RV283P-65A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN80

RV283P-80A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN100

RV283P-100A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN125

RV283P-125A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN150

RV283P-150A

Check valve with grey cast iron housing, powder coated inside and outside. For connection size DN200

RV283P-200A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN50

FY69P-50A

Page 406: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-19

Pressure Reducing Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Spare Parts

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN65

FY69P-65A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN80

FY69P-80A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN100

FY69P-100A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN125

FY69P-125A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN150

FY69P-150A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN200

FY69P-200A

Reverse-rinsing filter with red bronze housing and filter bowl. For connection size DN65 F76S-65FA

Reverse-rinsing filter with red bronze housing and filter bowl. For connection size DN80 F76S-80FA

Reverse-rinsing filter with red bronze housing and filter bowl. For connection size DN100

F76S-100FA

Diaphragm for connection size DN50 5708000

Diaphragm for connection size DN65 5708100

Diaphragm for connection size DN80 5708200

Diaphragm for connection size DN100 5708300

Diaphragm for connection size DN125 5708400

Diaphragm for connection size DN150 5708500

Diaphragm for connection size DN200 5708600

Set of seals for connection size DN50 0901353

Set of seals for connection size DN65 0901354

Set of seals for connection size DN80 0901355

Set of seals for connection size DN100 0901356

Set of seals for connection size DN125 0901357

Set of seals for connection size DN150 0901358

Set of seals for connection size DN200 0901359

Guide bush with seal for connection size DN50 0900255

Guide bush with seal for connection size DN65 0900256

Guide bush with seal for connection size DN80 0900257

Guide bush with seal for connection size DN100 0900258

Guide bush with seal for connection size DN125 0900259

Guide bush with seal for connection size DN150 0900260

Guide bush with seal for connection size DN200 0900261

Seat bush with seal for connection size DN50 0900247

Seat bush with seal for connection size DN65 0900248

Seat bush with seal for connection size DN80 0900249

Seat bush with seal for connection size DN100 0900250

Seat bush with seal for connection size DN125 0900251

Seat bush with seal for connection size DN150 0900252

Seat bush with seal for connection size DN200 0900253

Pressure gauge, 0 - 16 bar M07M-A16

Pressure gauge, 0 - 4 bar M07M-A4

Page 407: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-20

Pressure Reducing Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification.By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 16 flanged connections

Spare Parts

Diaphragm-actuated pressure reducing valve with cartridge insert, D15S

Medium type drinking water

Body material ductile cast iron

Spring bonnet material ductile cast iron

Body finishing powder coating

Port connection flanges

Max. media temperature 65 oC

Pressure rating PN16

Pressure setpoint range 1,5 ... 6,5 bar

Balanced seat design yes

Additional description • Patented cartridge solution for easy assembly and maintenance

• One cartridge insert fits all nominal widths, making warehousing efficient

• Meets all requirements of DIN EN 1567• None of the materials used exceed the permissible limits for

lead content specified by DIN 50930 Part 6• Functionality and performance have been confirmed by an

accelerated life test with over 400,000 cycles (requirement acc. to DIN EN 1567: 200,000 cycles)

DN size Flow capacity Kvs Typemm

65 47 D15S-65A80 70 D15S-80A

100 110 D15S-100A

Valve insert complete for sizes DN65, DN80, DN100 0904120

Set of seals complete for sizes DN65, DN80, DN100 0904121

Pressure gauge, ranges 0 - 10 bar M07M-A10

Pressure gauge, ranges 0 - 16 bar M39M-A16

Page 408: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-21

Pressure Reducing Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 25 flanged connections

Accessories

Spare Parts

Standard pattern pressure reducing valve with flanged connections, D16

Medium type water/air

Media Water, compressed air and nitrogen

Body material red bronze RG5

Spring bonnet material metal

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN25

Filter mesh 0,5 mm

Pressure setpoint range 1,5 ... 12 bar

Balanced seat design yes

Additional description • The outlet pressure is set by turning the adjustment knob• G 1/4" pressure gauge connections on inlet and outlet• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully exchanged • Easily retrofittable to convert valve to a reverse-rinsing filter

combination

DN size (mm) Flow capacity Kvs Type15 3 D16-15A20 3,3 D16-20A25 8,5 D16-25A32 10,1 D16-32A40 13,5 D16-40A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 4 bar M38K-A4

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar M38K-A10

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar M38K-A16

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 25 bar M38K-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Reverse-rinsing filter with red bronze filter cup. Reverse-rinsing filter for retro-conversion of a pressure reducing valves to a filter combination unit

_FN09S-AM

Valve insert complete (without filter) for sizes DN 15 + DN 20 D16A-15

Valve insert complete (without filter) for sizes DN 25 + DN 32 D16A-25

Valve insert complete (without filter) for size DN 40 D16A-40

Replacement filter insert for sizes DN 15 + DN 20 ES16-15

Replacement filter insert for sizes DN 25 + DN 32 ES16-25

Replacement filter insert for size DN 40 ES16-40

Brass blanking plug with O-ring (5 pcs) S06M-1/4

Brass filter bowl with O-ring for sizes DN 15 + DN 20 SM06T-1/2

Brass filter bowl with O-ring for sizes DN 25 + DN 32 SM06T-1B

Brass filter bowl with O-ring for size DN 40 SM06T-11/2

Page 409: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-22

Pressure Reducing Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 25 flanged connections

Accessories

Spare Parts

Low pressure pattern pressure reducing valve with flanged connections, D16N

Medium type water/air

Media Water, compressed air and nitrogen

Body material red bronze RG5

Spring bonnet material metal

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN25

Filter mesh 0,5 mm

Pressure setpoint range 0,5 ... 2 bar

Balanced seat design yes

Additional description • The outlet pressure is set by turning the adjustment knob• G 1/4" pressure gauge connections on inlet and outlet• The adjustment spring is not in contact with the potable water• The valve insert is of high quality synthetic material and can be

fully interchanged • Easily retrofittable to convert valve to a reverse-rinsing filter

combination

DN size (mm) Flow capacity Kvs Type15 3 D16N-15A20 3,3 D16N-20A25 8,5 D16N-25A32 10,1 D16N-32A40 13,5 D16N-40A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 4 bar M38K-A4

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar M38K-A10

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar M38K-A16

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 25 bar M38K-A25

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Reverse-rinsing filter with red bronze filter cup. Reverse-rinsing filter for retro-conversion of a pressure reducing valves to a filter combination unit

_FN09S-AM

Valve insert complete (without filter) for sizes DN 15 + DN 20 D16NA-15

Valve insert complete (without filter) for sizes DN 25 + DN 32 D16NA-25

Valve insert complete (without filter) for size DN 40 D16NA-40

Replacement filter insert for sizes DN 15 + DN 20 ES16-15

Replacement filter insert for sizes DN 25 + DN 32 ES16-25

Replacement filter insert for size DN 40 ES16-40

Brass blanking plug with o-ring (5 pcs) S06M-1/4

Brass filter bowl with o-ring for sizes DN 15 + DN 20 SM06T-1/2

Brass filter bowl with o-ring for sizes DN 25 + DN 32 SM06T-1B

Brass filter bowl with o-ring for size DN 40 SM06T-11/2

Page 410: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-23

Pressure Reducing Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure reducing valves of this type protect installations against excessive pressure from the supply. They can be used for household, industrial or commercial applications within the range of their specification. By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

With PN 25 flanged connections

Spare Parts

Standard pattern pressure reducing valve with flanged connections, D17P

Medium type water/air

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Body material sperulitic cast iron GGG40

Spring bonnet material metal

Body finishing powder coating

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN25

Balanced seat design yes

Additional description • Non-rising stem for setting outlet pressure and position indicator on spring bonnet (except for DN 200 mm)

• The adjustment spring is not in contact with the potable water• With outlet pressure gauge• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe

DN size Flow capacity Kvs Pressure setpoint range Typemm bar

50 28 1,5 ... 8 D17P-50B65 47 1,5 ... 8 D17P-65B80 70 1,5 ... 8 D17P-80B

100 110 1,5 ... 8 D17P-100B150 250 1,5 ... 8 D17P-150B200 380 1,5 ... 6 D17P-200B

Pressure gauge, 0 - 10 bar M07M-A10

Page 411: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-24

Pressure Regulators with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure Regulators with flanges

Pressure regulators of this type protect downstream installations against excessive supply pressure. Pressure regulators are used when the capacity of direct controlled pressure reducing valves are insufficient. Their compact construction makes them particularly suitable for installation in limited spaces, for example in ducts. By using a pressure regulator, pressurization damage is avoided and water consumption reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Flanges, PN 16, ISO 2084

Pressure regulator, DR300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Pressure setpoint range 1 ... 12 bar

Additional description • High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves• No external energy required for operation

DN size Flow capacity Kvs Typemm

50 43 DR300-50A65 43 DR300-65A80 103 DR300-80A

100 167 DR300-100A150 407 DR300-150A200 676 DR300-200A250 1160 DR300-250A300 1600 DR300-300A350 1600 DR300-350A400 3300 DR300-400A450 3300 DR300-450A

Page 412: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-25

Pressure Regulators with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Flanges, PN 25, ISO 2084

Spare Parts

DN size Flow capacity Kvs Typemm

50 43 DR300-50B65 43 DR300-65B80 103 DR300-80B

100 167 DR300-100B150 407 DR300-150B200 676 DR300-200B250 1160 DR300-250B300 1600 DR300-300B350 1600 DR300-350B400 3300 DR300-400B450 3300 DR300-450B

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-PR

Pressure gauge M07K-A16

Page 413: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

18-26 http://products.ecc.emea.honeywell.com/europe

Page 414: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Filters, Strainers, Filter combinations, residential/industrial Page

Filters 19-2Filters with flanges 19-18Strainers 19-20Strainers with flanges 19-22Filter Combinations 19-24Actuators for Filters 19-40

Page 415: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-2

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Filters

F76S reverse rinsing filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The appliances correspond to the requirements of current DIN/DVGW specifications.

Threaded male connections, filter mesh size 100 micron

Threaded male connections, red-bronze filter bowl, filter mesh size 100 micron

Without connections, filter mesh size 100 micron, DN is based on connection size of tailpiece

Reverse rinsing fine filter, F76S

Approvals DIN/DVGW-certified

Filter type reverse rinsing

Medium type water

Body material brass, dezincification resistant

Filter mesh 100 micron

Reverse rinsing with filtered water

yes

Mounting position horizontal

Additional description • Double Spin Technology for connection sizes 1/2" to 11/4" - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when the next manual reverse rinsing is due• Automatic reverse rinsing actuator can be retrofitted using

bayonet connector• Large filter surface

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

external threads 1/2 15 40 PN16 4,8 • F76S-1/2AAexternal threads 3/4 20 40 PN16 7,2 • F76S-3/4AAexternal threads 1 25 40 PN16 9,8 • F76S-1AAexternal threads 1 1/4 32 40 PN16 10,7 • F76S-11/4AAexternal threads 1 1/2 40 40 PN16 21 • F76S-11/2AAexternal threads 2 50 40 PN16 22 • F76S-2AA

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

external threads 1/2 15 70 PN25 4,8 – F76S-1/2AAMexternal threads 3/4 20 70 PN25 7,2 – F76S-3/4AAMexternal threads 1 25 70 PN25 9,8 – F76S-1AAMexternal threads 1 1/4 32 70 PN25 10,7 – F76S-11/4AAMexternal threads 1 1/2 40 70 PN25 21 – F76S-11/2AAMexternal threads 2 50 70 PN25 22 – F76S-2AAM

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

– 3/4 20 40 PN16 7,2 • F76S-3/4EA– 1 25 40 PN16 9,8 • F76S-1EA– 1 1/4 32 40 PN16 10,7 • F76S-11/4EA– 1 1/2 40 40 PN16 21 • F76S-11/2EA– 2 50 40 PN16 22 • F76S-2EA

Page 416: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-3

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Inlet check valve, Connction size 1/2" RV277-1/2A

Inlet check valve, Connction size 3/4" RV277-3/4A

Inlet check valve, Connction size 1" RV277-1A

Inlet check valve, Connction size 11/4" RV277-11/4A

Inlet check valve, Connction size 11/2" RV277-11/2A

Inlet check valve, Connction size 2" RV277-2A

Differential pressure switch for sizes R 1/2 + R 3/4 DDS76-1/2

Differential pressure switch for sizes R 1 + R 1 1/4 DDS76-1

Differential pressure switch for sizes R 1 1/2 + R 2 DDS76-11/2

Filter insert complete. Filter meshes 20 micron. Connection size 1/2" - 3/4" AF11S-1/2B

Filter insert complete. Filter meshes 50 micron. Connection size 1/2" - 3/4" AF11S-1/2C

Filter insert complete. Filter meshes 200 micron. Connection size 1/2" - 3/4" AF11S-1/2D

Filter insert complete. Filter meshes 300 micron. Connection size 1/2" - 3/4" AF11S-1/2E

Filter insert complete. Filter meshes 500 micron. Connection size 1/2" - 3/4" AF11S-1/2F

Filter insert complete. Filter meshes 20 micron. Connection size 1" - 11/4" AF11S-1B

Filter insert complete. Filter meshes 50 micron. Connection size 1" - 11/4" AF11S-1C

Filter insert complete. Filter meshes 200 micron. Connection size 1" - 11/4" AF11S-1D

Filter insert complete. Filter meshes 300 micron. Connection size 1" - 11/4" AF11S-1E

Filter insert complete. Filter meshes 500 micron. Connection size 1" - 11/4" AF11S-1F

Filter insert complete. Filter meshes 20 micron. Connection size 11/2" - 2" AF11S-11/2B

Filter insert complete. Filter meshes 50 micron. Connection size 11/2" - 2" AF11S-11/2C

Filter insert complete. Filter meshes 200 micron. Connection size 11/2" - 2" AF11S-11/2D

Filter insert complete. Filter meshes 300 micron. Connection size 11/2" - 2" AF11S-11/2E

Filter insert complete. Filter meshes 500 micron. Connection size 11/2" - 2" AF11S-11/2F

Filter insert complete for filters with Double Spin Technology, filter mesh size 20 micron. Connection size 1/2" - 3/4"

AF11DS-1/2B

Filter insert complete for filters with Double Spin Technology, filter mesh size 50 micron. Connection size 1/2" - 3/4"

AF11DS-1/2C

Filter insert complete for filters with Double Spin Technology, filter mesh size 200 micron. Connection size 1/2" - 3/4"

AF11DS-1/2D

Filter insert complete for filters with Double Spin Technology, filter mesh size 300 micron. Connection size 1/2" - 3/4"

AF11DS-1/2E

Filter insert complete for filters with Double Spin Technology, filter mesh size 500 micron. Connection size 1/2" - 3/4"

AF11DS-1/2F

Filter insert complete for filters with Double Spin Technology, filter mesh size 20 micron. Connection size 1" - 11/4"

AF11DS-1B

Filter insert complete for filters with Double Spin Technology, filter mesh size 50 micron. Connection size 1" - 11/4"

AF11DS-1C

Filter insert complete for filters with Double Spin Technology, filter mesh size 200 micron. Connection size 1" - 11/4"

AF11DS-1D

Filter insert complete for filters with Double Spin Technology, filter mesh size 300 micron. Connection size 1" - 11/4"

AF11DS-1E

Filter insert complete for filters with Double Spin Technology, filter mesh size 500 micron. Connection size 1" - 11/4"

AF11DS-1F

Threaded male connection, connection size 1/2" VST06-1/2A

Threaded male connection, connection size 3/4" VST06-3/4A

Threaded male connection, connection size 1" VST06-1A

Threaded male connection, connection size 11/4" VST06-11/4A

Threaded male connection, connection size 11/2" VST06-11/2A

Threaded male connection, connection size 2" VST06-2A

Page 417: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-4

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16

Spare Parts

The reverse rinsing filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand.The fine filters are used in systems where an existing pressure reducing valve is fitted or where one is not required. Both horizontal and vertical installation is possible.

Solder union connection, connection size 1/2" VST06-1/2B

Solder union connection, connection size 3/4" VST06-3/4B

Solder union connection, connection size 1" VST06-1B

Solder union connection, connection size 11/4" VST06-11/4B

Solder union connection, connection size 11/2" VST06-11/2B

Solder union connection, connection size 2" VST06-2B

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M76K-A16

Filter insert complete, filter mesh size 100 micron, for sizes R 1/2 - R 3/4 AF11S-1/2A

Filter insert complete, filter mesh size 100 micron, for sizes R 1 - R 1 1/4 AF11S-1A

Filter insert complete, filter mesh size 100 micron, for sizes R 1 1/2 - R 2 AF11S-11/2A

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes R 1/2 - R 3/4

AF11DS-1/2A

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes R 1 - R 1 1/4

AF11DS-1A

Clear filter bowl complete for sizes R 1/2 - R 1 1/4 KF11S-1A

Clear filter bowl complete for sizes R 1 1/2 - R 2 KF11S-11/2A

Red-bronze filter bowl for sizes R 1/2 - R 1 1/4 FT09RS-1A

Red-bronze filter bowl for sizes R 1 1/2 - R 2 FT09RS-11/2A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removing the filter - sizes R 1/2 - R 3/4 ZR10K-3/4

Double ring wrench for removing the filter - sizes R 1 1/2 - R 2 ZR10K-11/2

Double ring wrench for removing the filter - sizes R 1 - R 1 1/4 ZR10K-1

Reverse rinsing fine filter with rotatable connector piece, F74CS

Approvals DVGW-certified

Filter type reverse rinsing

Medium type water

Body material synthetic material

Port connection external threads

Max. media temperature 30 oC

Pressure rating PN16

Transparant strainer chamber yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates time when next reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted• Large filter surface• Shock resistant clear synthetic material filter bowl - enables easy

checking of filter contamination• Filter insert fully replaceable• Standardised discharge connection• Meets KTW recommendations for potable water

Page 418: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-5

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

With rotatable connector piece, filter mesh size 95/110 micron

With rotatable connector piece, filter mesh size 50 micron

With rotatable connector piece, filter mesh size 200 micron

Accessories

Spare Parts

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 5,3 95/110 F74CS-1/2AA3/4 20 7,9 95/110 F74CS-3/4AA

1 25 9 95/110 F74CS-1AA1 1/4 32 10 95/110 F74CS-11/4AA

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 5,3 50 F74CS-1/2AC3/4 20 7,9 50 F74CS-3/4AC

1 25 9 50 F74CS-1AC1 1/4 32 10 50 F74CS-11/4AC

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 5,3 200 F74CS-1/2AD3/4 20 7,9 200 F74CS-3/4AD

1 25 9 200 F74CS-1AD1 1/4 32 10 200 F74CS-11/4AD

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1/2"

DA74CS-1/2A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 3/4"

DA74C-3/4A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1"

DA74C-1A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 11/4"

DA74C-11/4A

Automatic reverse rinsing actuator for automatic filter cleaning at presettable intervals

Z74S-AN

Retrofit pressure rudicing valve insert set for retrofitting to upgrade to a filter combination

D06FR

Filter insert complete, filter mesh size 95/110 micron AF74-1A

Filter insert complete, filter mesh size 50 micron AF74-1C

Filter insert complete, filter mesh size 200 micron AF74-1D

Clear filter bowl complete KF74CS-1A

Pressure gauge, rear connection thread G1/4", Range:0 - 16 bar M74CS-A16

Wrench for removing filter bowl and spring bonnet ZR74CS

Page 419: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-6

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16F76CS reverse rinsing filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The appliances correspond to the requirements of current DIN/DVGW specifications. F76CS fine filters are especially suitable for retrofitting to, or upgrading of existing water systems.The rotatable connector piece enables the unit to be fitted where space is very restricted in either horizontal or vertical pipework.

Filter mesh size 100 micron

Reverse rinsing fine filter with rotatable connector flange, F76CS

Approvals DVGW-approval requested

Filter type reverse rinsing

Medium type water

Body material brass, dezincification resistant

Port connection external threads

Max. media temperature 40 oC

Pressure rating PN16

Filter mesh 100 micron

Transparant strainer chamber yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description Double Spin Technology - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Filtered water supplied even during reverse rinsing• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when the next manual reverse rinsing is due• Automatic reverse rinsing actuator can be retrofitted using

bayonet connector• Large filter surface

Port diameter DN size Flow capacity Kvs Typeinch mm

3/4 20 7,3 F76CS-3/4AA1 25 8,7 F76CS-1AA

1 1/4 32 9 F76CS-11/4AA

Page 420: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-7

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure

FT09RS-1A

Retrofit pressure reducing valve to upgrade F76CS to a filter combination D06FB-1A

Inlet check valve, connection size 3/4" RV277-3/4A

Inlet check valve, connection size 1" RV277-1A

Inlet check valve, connection size 11/4" RV277-11/4A

Threaded male connection, Connection size 3/4" VST06-3/4A

Threaded male connection, Connection size 1" VST06-1A

Threaded male connection, Connection size 11/4" VST06-11/4A

Solder union connection, Connection size 3/4" VST06-3/4B

Solder union connection, Connection size 1" VST06-1B

Solder union connection, Connection size 11/4" VST06-11/4B

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 25 bar

M07M-A25

Filter insert complete for filters with Double Spin Technology AF11DS-1A

Clear filter bowl KF11S-1A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removing filterbowl ZR10K-3/4

Page 421: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-8

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The reverse rinsing filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand.The fine filters are used in systems where an existing pressure reducing valve is fitted or where one is not required. Both horizontal and vertical installation is possible.

Retrofit version without rotatable connector piece, filter mesh size 95/110 micron

Accessories

Spare Parts

Retrofit reverse rinsing fine filter, FN74CS

Approvals DVGW-certified with rotatable connector piece DA74CS

Media Water

Body material synthetic material

Max. media temperature 30 oC

Pressure rating PN16

Filter mesh 95/110 micron

Transparant strainer chamber yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates time when next reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted• Large filter surface• Shock resistant clear synthetic material filter bowl - enables easy

checking of filter contamination• Filter insert fully replaceable• Standardised discharge connection• Meets KTW recommendations for potable water

TypeFN74CS-1A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1/2"

DA74CS-1/2A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 3/4"

DA74C-3/4A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1"

DA74C-1A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 11/4"

DA74C-11/4A

Automatic reverse rinsing actuator for automatic filter cleaning at presettable intervals

Z74S-AN

Retrofit pressure reducing valve insert set for retrofitting to upgrade to a filter combination

D06FR-1A

Filter insert complete, filter mesh size 95/110 micron AF74-1A

Filter insert complete, filter mesh size 50 micron AF74-1C

Filter insert complete, filter mesh size 200 micron AF74-1D

Clear filter bowl complete KF74CS-1A

Pressure gauge, rear connection thread G1/4", Range:0 - 16 bar M74CS-A16

Wrench for removing filter bowl and spring bonnet ZR74CS

Page 422: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-9

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

FN76CS reverse rinsing filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The appliances correspond to the requirements of current DIN/DVGW specifications. FN76CS fine filters are especially suitable for retrofitting to, or upgrading of existing water systems in which an existing filter is to be replaced. The existing connectors are then reused. Where connection sizes are different, an adapter connector can be used.

Filter mesh size 100 micron

Accessories

Spare Parts

Retrofit reverse rinsing fine filter for connection flange, FN76CS

Approvals DVGW-approval requested

Media Water

Body material brass, dezincification resistant

Port diameter 1 inch

DN size 25 mm

Max. media temperature 40 oC

Pressure rating PN16

Flow capacity Kvs 8,7

Filter mesh 100 micron

Transparant strainer chamber yes

Reverse rinsing with filtered water yes

Mounting position horizontal or vertical

Additional description • Double Spin Technology - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when the next manual reverse rinsing is due• Automatic reverse rinsing actuator can be retrofitted using

bayonet connector• Large filter surface

TypeFN76CS-1A

Rotatable connector piece in connection size R3/4 DA74C-3/4A

Rotatable connector piece in connection size R1 DA74C-1A

Rotatable connector piece in connection size R1 1/4 DA74C-11/4A

Intermediate connector for conversion of fine filters with rotatable connector pieces (R 1 1/4 and R 1 1/2) e.g. Cillit type 77 into retrofit FKN 76 CS filter combinations

ZA76C-11/4

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure FT09RS-1A

Retrofit pressure reducing valve to upgrade F76CS to a filter combination D06FB-1A

Inlet check valve, connection size 3/4" RV277-3/4A

Inlet check valve, connection size 1" RV277-1A

Inlet check valve, connection size 11/4" RV277-11/4A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar M07M-A16

Filter insert complete, filter mesh size 100 micron AF11DS-1A

Clear filter bowl complete KF11S-1A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removing filter bowl ZR10K-3/4

Page 423: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-10

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Rinseable MiniPlus fine filters ensure a continuous supply of filtered water. The fine filter stops the flow of particulates, for example rust particles, strands of hemp, or grains of sand. Sediment collected at the bottom of the filter bowl can simply be removed by flushing with the flick of a finger. Compact in size, these filters were designed to fit where space is limited.

Threaded male connections, filter mesh size 100 micron

Threaded male connections, filter bowl of dezincification resistance brass, filter mesh size 100 micron

Without connections, filter mesh size 100 micron

Rinseable fine filter, MiniPlus-FF06

Approvals Connection sizes 1/2" and 3/4" DIN/DVGW-certified

Filter type rinsable

Medium type water

Body material brass, dezincification resistant

Filter mesh 100 micron

Mounting position horizontal

Additional description • Easy installation• Shock resistant clear synthetic material filter bowl enables easy

inspection of filter contamination• FF06-...AAM versions with brass filter bowl - suitable for hot water

installations• Filter bowl and sieve easily exchanged• Body with female and male threads• Reliable and tested

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

external threads 1/2 15 40 PN16 4 • FF06-1/2AAexternal threads 3/4 20 40 PN16 5,8 • FF06-3/4AAexternal threads 1 25 40 PN16 10,4 • FF06-1AAexternal threads 1 1/4 32 40 PN16 10,4 • FF06-11/4AA

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

external threads 1/2 15 70 PN25 4 – FF06-1/2AAMexternal threads 3/4 20 70 PN25 5,8 – FF06-3/4AAMexternal threads 1 25 70 PN25 10,4 – FF06-1AAMexternal threads 11/4 32 70 PN25 10,4 – FF06-11/4AAM

Portconnection

Portdiameter

DNsize

Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

internal threads 1/2 15 40 PN16 4 • FF06-1/2EAinternal threads 3/4 20 40 PN16 5,8 • FF06-3/4EAinternal threads 1 25 40 PN16 10,4 • FF06-1EA

Page 424: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-11

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

In applications where only one filter type is needed a SIMPLEX filter with the selected filter cartridge can be used. Activated carbon removes dissolved organic material and chlorine. The polypropylene cartridge holds back undissolved matter.The filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of particulates, for example rust particles, strands of hemp and grains of sand. The filters can be applied to rain water treatment within the range of their specifications.

Simplex water filter

Accessories

Spare Parts

Inlet check valve, connection size 1/2" RV277-1/2A

Inlet check valve, connection size 3/4" RV277-3/4A

Inlet check valve, connection size 1" RV277-1A

Inlet check valve, connection size 11/4" RV277-11/4A

Threaded male connection, connection size 1/2" VST06-1/2A

Threaded male connection, connection size 3/4" VST06-3/4A

Threaded male connection, connection size 1" VST06-1A

Soldered union connection, connection size 1/2" VST06-1/2B

Soldered union connection, connection size 3/4" VST06-3/4B

Soldered union connection, connection size 1" VST06-1B

Exchange filter insert complete for size R 1/2 + R 3/4 AS06-1/2A

Exchange filter insert complete for sizes R 1 + R 1 1/4 AS06-1A

Clear filter bowl complete with filter and carrier body, for size R 1/2 KF06-1/2A

Clear filter bowl complete with filter and carrier body, for size R 3/4 - R 1 1/4 KF06-1A

Double ring wrench. For removing filter bowl ZR06F

SIMPLEX water filter, or activated carbon filter, FF20

Medium type rain water

Body material synthetic material

Port connection internal threads

Port diameter 3/4 inch

Max. media temperature 45 oC

Pressure rating PN16

Transparant strainer chamber yes

Mounting position horizontal

Additional description • Large filter surface• Filter insert fully interchangeable• Very simple operation• Reliable and tested

Flow capacity Kvs Filter mesh (micron) Type6 25 FF20-MF

1,4 5 FF20-AC

Inlet check valve _RV277

Check valve _RV284

Connection set with threaded male connection _VST06-A

Connection set with union soldered connection _VST06-B

Replacement filter cartridge FF20-DMF

Replacement active carbon cartridge FF20-GAC

Page 425: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-12

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The DUPLEX water filter combines two different filter cartridges in one housing. Activated carbon removes dissolved organic material and chlorine. The polypropylene cartridge holds back undissolved matter.The filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of particulates, for example rust particles, strands of hemp and grains of sand. The filters can be applied to rain water treatment within the range of their specifications.

Duplex water filter

Accessories

Spare Parts

DUPLEX water filter with activated carbon cartridge, FF40

Medium type rain water

Body material synthetic material

Port connection internal threads

Port diameter 3/4 inch

DN size 20 mm

Max. media temperature 45 oC

Pressure rating PN16

Flow capacity Kvs 1,4

Filter mesh 25 micron

Transparant strainer chamber yes

Mounting position horizontal

Additional description • Large filter surface• Filter insert fully interchangeable• Very simple operation• Reliable and tested

TypeFF40

Inlet check valve _RV277

Check valve _RV284

Connection set with threaded male connection _VST06-A

Connection set with union soldered connection _VST06-B

Replacement filter cartridge FF20-DMF

Replacement active carbon cartridge FF20-GAC

Page 426: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-13

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

The TRIPLEX water filter combines three different filter cartridges in one housing. Washable prefilter, the polypropylene cartridge holds back undissolved matter. Activated Carbon cartridge filters out fine particles, eliminates of unpleasant odors and flavours caused by chlorine or other organic substances, removes of pesticides, insecticides, chlorinate solvents.The filters ensure a continuous supply of filtered water. The fine filter prevents the ingress of particulates, for example rust particles, strands of hemp and grains of sand. The filters can be applied to rain water treatment within the range of their specifications.

Triplex water filter

Accessories

Spare Parts

TRIPLEX filter with washable prefilter, FF60

Medium type rain water

Body material synthetic material

Port connection internal threads

Port diameter 3/4 inch

DN size 20 mm

Max. media temperature 45 oC

Pressure rating PN16

Flow capacity Kvs 0,8

Filter mesh 25 micron

Transparant strainer chamber yes

Mounting position horizontal

Additional description • Large filter surface• Filter insert fully interchangeable• Very simple operation• Reliable and tested

TypeFF60

Inlet check valve _RV277

Check valve _RV284

Connection set with threaded male connection _VST06-A

Connection set with union soldered connection _VST06-B

Replacement filter cartridge, 100 micron FF60-WMF

Replacement filter cartridge, 25 micron FF20-DMF

Replacement active carbon cartridge FF20-GAC

Page 427: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-14

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16HABEDO FN09S retrofit reverse rinsing filters are suitable for retrofitting to existing D06F pressure reducing valves. The converted pressure reducing valve then fulfils the same functions as a Honeywell Braukmann filter combination. The fine filter prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The appliances correspond to current DIN/DVGW specifications.

Filter mesh size 100 micron. Port diameter 1 inch fits for D06F DN size 25 mm only for production dates 1977 - 1991 and for D06F DN size 40 mm only for production dates 1977 - 1996.

Red bronze filter bowl, filter mesh size 100 micron. Port diameter 1 inch fits for D06F DN size 25 mm only for production dates 1977 - 1991 and for D06F DN size 40 mm only for production dates 1977 - 1996.

Filter mesh size 100 micron. Fits for D06F DN size 25 mm only for production dates 1991 and onwards and for D06F DN size 40 mm only for production dates 1996 and onwards.

Red bronze filter bowl, filter mesh size 100 micron. Fits for D06F DN size 25 mm only for production dates 1991 and onwards and for D06F DN size 40 mm only for production dates 1996 and onwards.

Retrofit reverse rinsing fine filter for D06F pressure reducing valves, FN09S

Media Water• The filter is constructed for drinking water installations. In case of

a process water application the filter has to be proven individually.

Filter mesh 100 micron

Reverse rinsing with filtered water

yes

Mounting position horizontal

Additional description 1/2" Port connection fits for D06F 1/2" and 3/4", 1" Port connection fits for D06F 1" and 1 1/4", 1 1/2" Port connection fits for D06F 1 1/2" and 2". Adapter made of dezincification resistant brass, filter bowl made of synthetic material or red-bronze.

• Easily fitted to existing pressure reducing valves• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when next manual reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connection can

be retrofitted

Port diameter DN size Max. mediatemperature

Pressure rating Transparant strainerchamber

Type

inch mm oC

1/2 15 40 PN16 • FN09S-1/2A1 25 40 PN16 • FN09S-1A

1 1/2 40 40 PN16 • FN09S-11/2A

Port diameter DN size Max. mediatemperature

Pressure rating Transparant strainerchamber

Type

inch mm oC

1/2 15 70 PN25 – FN09S-1/2AM1 25 70 PN25 – FN09S-1AM

1 1/2 40 70 PN25 – FN09S-11/2AM

Port diameter DN size Max. mediatemperature

Pressure rating Transparant strainerchamber

Type

inch mm oC

1 25 40 PN16 • FN09S-1AN

Port diameter DN size Max. mediatemperature

Pressure rating Transparant strainerchamber

Type

inch mm oC

1 25 70 PN25 – FN09S-1AMN

Page 428: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-15

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Double ring wrench for removal of filter bowl, for R 1/2 - R 1 1/4 ZR10K-1

Double ring wrench for removal of filter bowl, for R 1 1/2 + R 2 ZR10K-11/2

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1/2 - R 1 1/4

FT09RS-1A

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1 1/2 + R 2

FT09RS-11/2A

Filter insert complete, filter mesh size 100 micron, for sizes R 1/2 - R 1 1/4 AF11S-1A

Filter insert complete, filter mesh size 20 micron, for sizes R 1/2 - R 1 1/4 AF11S-1B

Filter insert complete, filter mesh size 50 micron, for sizes R 1/2 - R 1 1/4 AF11S-1C

Filter insert complete, filter mesh size 200 micron, for sizes R 1/2 - R 1 1/4 AF11S-1D

Filter insert complete, filter mesh size 300 micron, for sizes R 1/2 - R 1 1/4 AF11S-1E

Filter insert complete, filter mesh size 500 micron, for sizes R 1/2 - R 1 1/4 AF11S-1F

Filter insert complete, filter mesh size 100 micron, for sizes R 1 1/2 - R 2 AF11S-11/2A

Filter insert complete, filter mesh size 20 micron, for sizes R 1 1/2 - R 2 AF11S-11/2B

Filter insert complete, filter mesh size 50 micron, for sizes R 1 1/2 - R 2 AF11S-11/2C

Filter insert complete, filter mesh size 200 micron, for sizes R 1 1/2 - R 2 AF11S-11/2D

Filter insert complete, filter mesh size 300 micron, for sizes R 1 1/2 - R 2 AF11S-11/2E

Filter insert complete, filter mesh size 500 micron, for sizes R 1 1/2 - R 2 AF11S-11/2F

Clear filter bowl complete for sizes R 1/2 - R 1 1/4 KF11S-1A

Clear filter bowl complete for sizes R 1 1/2 - R 2 KF11S-11/2A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Page 429: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-16

Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The Z11AS automatic reverse rinsing actuator provides fully automatic cleaning for all Honeywell reverse rinsing filters, filter combinations, water supply units and water distributor units. The reverse rinsing intervals are adjustable in sixteen steps between four minutes and three months. The Z11AS has an emergency running function in the event of power failure (only when batteries are fitted) and offers the possibility of manual operation of the reverse rinsing function. Connection options are available for differential pressure switching, remote control and remote monitoring.For fully automatic reverse rinsing of Honeywell filters, filter combinations and water supply unit.

For filters and filtercombinations HS10, F76C, FK76C, FKN76C, FN76C, FN09 (up to 1996)

For filters with flanges F76-F and F76S-F

Reverse rinsing actuator for fully automatic filter cleaning, Z11AS

Approvals CE

Media Water

Body material synthetic material

Max. media temperature 70 oC

Battery life Appr. 3 years

Cable length 1,5 m

Additional description Four LR6-1.5 V-Mignon/AA size alkali-manganese batteries (Batteries are not supplied with the appliance), time intervals 4 minutes to 3 months

• Pushbuttons give easy setting of intervals• Pushbutton for manual operation of reverse rinsing• LED indicator of time interval set• LED indicator of number of reverse rinsing cycles carried out• Settings are maintained even when electrical power fails

Product description Type230 V, 50/60 Hz, 10 W, with moulded Schuko electrical plug Z11AS-1/2A24 V, 50/60 Hz, 10 W, without electrical plug Z11AS-1/2B

Product description Type230 V, 50/60 Hz, 10 W, with moulded Schuko electrical plug Z11AS-1A24 V, 50/60 Hz, 10 W, without electrical plug Z11AS-1B

Page 430: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-17

Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

The Z11S automatic reverse rinsing actuator provides fully automatic cleaning for all Honeywell reverse rinsing filters, filter combinations, water supply units and water distributor units. The reverse rinsing intervals are adjustable in sixteen steps between four minutes and three months. The Z11S has an emergency running function in the event of power failure (only when batteries are fitted) and offers the possibility of manual operation of the reverse rinsing function. Connection options are available for differential pressure switching, remote control and remote monitoring.For fully automatic reverse rinsing of Honeywell filters, filter combinations, water supply unit and water distributor units.

For filters and filtercombinations HS10S, F76CS, FK76CS, FKN76CS, FN76CS, F74C, FK74C, FKN74C, FN74C and FN09S

The Z74S automatic reverse rinsing actuator provides fully automatic cleaning for all Honeywell Braukmann reverse rinsing filters, filter combinations and water supply units with bayonet connection. A bayonet connection enables fitting the Z74S without tools. The reverse rinsing interval is set permanently to 45 days. The Z74S automatic reverse rinsing actuator has a safety function which prevents the ball valve from opening when the battery voltage is too low and notifies this through an acoustic signal for approx. 2 days.Use reverse rinsing actuator Z74S for filters and filtercombinations HS10S, F76CS, FK76CS, FKN76CS, FN76CS, F74C, FK74C, FKN74C, FN74C and FN09S.

With bayonet connection

Reverse rinsing actuator for fully automatic filter cleaning, Z11S

Approvals CE

Media Water

Body material synthetic material

Max. media temperature 70 oC

Battery life Appr. 3 years

Cable length 1,5 m

Additional description Four LR6-1.5 V-Mignon/AA size alkali-manganese batteries (Batteries are not supplied with the appliance), time intervals 4 minutes to 3 months

• Pushbuttons give easy setting of intervals• Pushbutton for manual operation of reverse rinsing• LED indicator of time interval set• LED indicator of number of reverse rinsing cycles carried out• Settings are maintained even when electrical power fails

Product description Type230 V, 50/60 Hz, 10 W, with moulded Schuko electrical plug Z11S-A24 V, 50/60 Hz, 10 W, without electrical plug Z11S-B

Reverse rinsing actuator for fully automatic filter cleaning, Z74S

Approvals CE

Media Water

Body material synthetic material

Max. media temperature 40 oC

Battery life Appr. 1 years

Additional description Three LR6-1.5 V-Mignon/AA size alkali-manganese batteries (Batteries are not supplied with the appliance)

• Bayonet connection enables fitting without tools• With locking mechanism which prevents the ball valve from

opening, if the battery voltage is too low to carry out the closing• Set during manufacture to 45 day interval• Battery operation• Manufactured with integral electrical suppression

TypeZ74S-A

Page 431: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-18

Filters with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Filters with flanges

F76S-F flanged reverse rinsing filters are for installations with high water demand. They can be used in large residential buildings, for central water supply and in commercial or industrial applications. F76S-F flanged filters have the same highly efficient reverse rinsing filtering system as the range of household fine filters. The F76S-F can be retrofitted with the Z11AS fully automatic reverse rinsing actuator and the DDS76 differential pressure switch. The use of a filter in a system prevents the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. With metal or plastics pipework, DIN 1988, Part 2 specifies that a filter should be fitted in the drinking water supply immediately after the water meter.

Filter mesh size 100 micron

Filter mesh size 20 micron

Filter mesh size 50 micron

Filter mesh size 200 micron

Filter mesh size 500 micron

Reverse rinsing fine filter with flanges, F76S-F

Approvals DIN/DVGW

Filter type reverse rinsing

Medium type water

Body material red bronze RG5

Port connection flanges

Max. media temperature 70 oC

Pressure rating PN16

Reverse rinsing with filtered water

yes

Mounting position horizontal

Additional description • Patented reverse rinsing system - fast and thorough cleaning of the filter with small amount of water

• Fully automatic reverse rinsing with retrofittable Z11AS automatic reverse rinsing actuator

• Differential pressure switch can be retrofitted• Reverse rinsing strainer mesh is covered during normal operation• Red bronze construction gives high level of corrosion protection

DN size (mm) Flow capacity Kvs Filter mesh (micron) Type65 90 100 F76S-65FA80 125 100 F76S-80FA

100 158 100 F76S-100FA125 158 100 F76S-125ZFA

DN size (mm) Flow capacity Kvs Filter mesh (micron) Type65 90 20 F76S-65FB80 125 20 F76S-80FB

100 158 20 F76S-100FB

DN size (mm) Flow capacity Kvs Filter mesh (micron) Type65 90 50 F76S-65FC80 125 50 F76S-80FC

100 158 50 F76S-100FC

DN size (mm) Flow capacity Kvs Filter mesh (micron) Type65 90 200 F76S-65FD80 125 200 F76S-80FD

100 158 200 F76S-100FD

DN size (mm) Flow capacity Kvs Filter mesh (micron) Type65 90 500 F76S-65FF80 125 500 F76S-80FF

100 158 500 F76S-100FF

Page 432: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-19

Filters with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11AS-1A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11AS-1B

Differential pressure switch for sizes DN 65 - DN 100 DDS76-1

Check valve in grey cast iron housing, powder coated inside and outside. DIN/DVGW tested in compulsory test sizes DN 65, DN 80 and DN 100. Connection size DN 65

RV283P-65A

Check valve in grey cast iron housing, powder coated inside and outside. DIN/DVGW tested in compulsory test sizes DN 65, DN 80 and DN 100. Connection size DN 80

RV283P-80A

Check valve in grey cast iron housing, powder coated inside and outside. DIN/DVGW tested in compulsory test sizes DN 65, DN 80 and DN 100. Connection size DN 100

RV283P-100A

Pressure reducing valve in grey cast iron housing, powder coated inside and outside. Connection size DN 65

D15P-65A

Pressure reducing valve in grey cast iron housing, powder coated inside and outside. Connection size DN 80

D15P-80A

Pressure reducing valve in grey cast iron housing, powder coated inside and outside. Connection size DN 100

D15P-100A

Pressure gauge with housing diameter 63 mm, connection thread G 1/4, range 0 - 16 bar

M76K-A16

Replacement sieve, filter mesh 100 micron, for size DN 65 ES76S-065A

Replacement sieve, filter mesh 100 micron, for size DN 80 ES76S-080A

Replacement sieve, filter mesh 100 micron, for size DN 100 ES76S-100A

Replacement sieve, filter mesh 200 micron, for size DN 65 ES76S-065D

Replacement sieve, filter mesh 200 micron, for size DN 80 ES76S-080D

Replacement sieve, filter mesh 200 micron, for size DN 100 ES76S-100D

Replacement sieve, filter mesh 50 micron, for size DN 65 ES76S-065C

Replacement sieve, filter mesh 50 micron, for size DN 80 ES76S-080C

Replacement sieve, filter mesh 50 micron, for size DN 100 ES76S-100C

Replacement sieve, filter mesh 500 micron, for size DN 65 ES76S-065F

Replacement sieve, filter mesh 500 micron, for size DN 80 ES76S-080F

Replacement sieve, filter mesh 500 micron, for size DN 100 ES76S-100F

Filter insert complete, filter mesh 100 micron, for size DN 65 AF76S-065A

Filter insert complete, filter mesh 100 micron, for size DN 80 AF76S-080A

Filter insert complete, filter mesh 100 micron, for size DN 100 AF76S-100A

Filter insert complete, filter mesh 200 micron, for size DN 65 AF76S-065D

Filter insert complete, filter mesh 200 micron, for size DN 80 AF76S-080D

Filter insert complete, filter mesh 200 micron, for size DN 100 AF76S-100D

Filter insert complete, filter mesh 50 micron, for size DN 65 AF76S-065C

Filter insert complete, filter mesh 50 micron, for size DN 80 AF76S-080C

Filter insert complete, filter mesh 50 micron, for size DN 100 AF76S-100C

Ball valve 5622100

Page 433: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-20

Strainers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Strainers

FY30 strainers are used in commercial and industrial applications within the limits of their specifications. They protect systems against malfunction and corrosion damage resulting from the ingress of foreign bodies such as welding beads, sealing materials, metal cuttings and rust etc. This extends the life of the downstream system and prevents early failure.

With double sieve, mesh size approximately 0.35 mm

With double sieve, mesh size approximately 0.18 mm

Spare Parts

Brass Y-strainer with threaded female connections, FY30

Media Water, oil, compressed air, steam and other non-aggressive media

Body material brass, dezincification resistant

Port connection internal threads

Max. media temperature 160 oC

Pressure rating PN16/PN6

Mounting position horizontal or vertical

Additional description • Low flow resistance because of good dynamic flow design of body• Brass and stainless steel construction gives good corrosion

resistance• Large strainer mesh surface area provides high dirt acceptance

capacity• Sieve carrier ensures good sealing within housing• Easy removal of sieve for cleaning

Port diameter (inch) DN size (mm) Flow capacity Kvs Zeta value Filter mesh (mm) Type3/8 10 2,1 3,6 0,35 FY30-3/8A1/2 15 3,8 5,6 0,35 FY30-1/2A3/4 20 7,1 5,1 0,35 FY30-3/4A

1 25 11,6 4,6 0,35 FY30-1A1 1/4 32 17,2 5,7 0,35 FY30-11/4A1 1/2 40 24 7,1 0,35 FY30-11/2A

2 50 40 6,2 0,35 FY30-2A

Port diameter (inch) DN size (mm) Flow capacity Kvs Zeta value Filter mesh (mm) Type3/8 10 2,1 3,6 0,18 FY30-3/8B1/2 15 3,8 5,6 0,18 FY30-1/2B3/4 20 7,1 5,1 0,18 FY30-3/4B

1 25 11,6 4,6 0,18 FY30-1B1 1/4 32 17,2 5,7 0,18 FY30-11/4B1 1/2 40 24 7,1 0,18 FY30-11/2B

2 50 40 6,2 0,18 FY30-2B

Replacement sieve, mesh size 0,35 mm, for size R 3/8 ES30-3/8A

Replacement sieve, mesh size 0,35 mm, for size R 1/2 ES30-1/2A

Replacement sieve, mesh size 0,35 mm, for size R 3/4 ES30-3/4A

Replacement sieve, mesh size 0,35 mm, for size R 1 ES30-1A

Replacement sieve, mesh size 0,35 mm, for size R 1 1/4 ES30-11/4A

Replacement sieve, mesh size 0,35 mm, for size R 1 1/2 ES30-11/2A

Replacement sieve, mesh size 0,35 mm, for size R 2 ES30-2A

Replacement sieve, mesh size 0,18 mm, for size R 3/8 ES30-3/8B

Replacement sieve, mesh size 0,18 mm, for size R 1/2 ES30-1/2B

Replacement sieve, mesh size 0,18 mm, for size R 3/4 ES30-3/4B

Replacement sieve, mesh size 0,18 mm, for size R 1 ES30-1B

Replacement sieve, mesh size 0,18 mm, for size R 1 1/4 ES30-11/4B

Replacement sieve, mesh size 0,18 mm, for size R 1 1/2 ES30-11/2B

Replacement sieve, mesh size 0,18 mm, for size R 2 ES30-2B

Page 434: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-21

Strainers

16

17

18

19

20

21

22

24

23

25

26

27

28

FY32 strainers are used in commercial and industrial applications within the limits of their specifications. They protect systems against malfunction and corrosion damage resulting from the ingress of foreign bodies such as welding beads, sealing materials, metal cuttings and rust etc. This extends the life of the downstream system and prevents early failure.

With double sieve, mesh size approximately 0,25 mm

Spare Parts

Red bronze Y-strainer with threaded female connections, FY32

Media Water, oil, compressed air, steam and other non-aggressive media

Body material red bronze RG5

Port connection internal threads

Max. media temperature 150 oC

Pressure rating PN16

Filter mesh 0,25 mm

Mounting position horizontal or vertical

Additional description • Low flow resistance because of good dynamic flow design of body• Brass and stainless steel construction gives good corrosion

resistance• Large strainer mesh surface area provides high dirt acceptance

capacity• Sieve carrier ensures good sealing within housing• Easy removal of sieve for cleaning

Port diameter DN size Flow capacity Kvs Zeta value Typeinch mm

1/4 8 1,4 3,3 FY32-1/4C3/8 10 1,65 5,9 FY32-3/8C1/2 15 3,8 5,6 FY32-1/2C3/4 20 6,12 6,8 FY32-3/4C

1 25 9,6 6,6 FY32-1C1 1/4 32 18,6 4,8 FY32-11/4C1 1/2 40 25,2 6,4 FY32-11/2C

2 50 40 6,2 FY32-2C

Replacement sieve with sealing ring, mesh size 0,25 mm, for sizes R 1/4 + R 3/8 ES32-3/8C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 1/2 ES32-1/2C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 3/4 ES32-3/4C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 1 ES32-1C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 1 1/4 ES32-11/4C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 1 1/2 ES32-11/2C

Replacement sieve with sealing ring, mesh size 0,25 mm, for size R 2 ES32-2C

Page 435: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-22

Strainers with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Strainers with flanges

FY69P strainers are used in commercial and industrial applications, as well as for central water supply systems within the limits of their specifications. They protect systems against malfunction and corrosion damage resulting from the ingress of foreign bodies such as welding beads, sealing materials, metal cuttings and rust etc. This extends the life of the downstream system and prevents early failure.

With double sieve, mesh size approximately 0,5 mm

Spare Parts

Grey cast iron Y-strainer with flange connections, FY69P

Media Water, oil, compressed air and other non-aggressive media up to 16,0 bar; steam up to 4,0 bar

Body material cast iron GG25

Body finishing powder coating

Port connection flanges

Max. media temperature 150 oC

Pressure rating PN16

Filter mesh 0,5 mm

Mounting position horizontal or vertical

Additional description • Low flow resistance because of good dynamic flow design of body• Powder coated inside and outside, which is toxicologically and

physiologically safe• Stainless steel construction gives double sieve good corrosion

resistance• Large strainer mesh surface area provides high dirt acceptance

capacity• Dirt particles or condensate in compressed air systems can be

flushed out with blanking plug removed

DN size Flow capacity Kvs Zeta value Typemm

15 4,9 3,4 FY69P-15A20 8,5 3,5 FY69P-20A25 14,6 2,9 FY69P-25A32 22,3 2,1 FY69P-32A40 33,5 3,6 FY69P-40A50 61 2,7 FY69P-50A65 107 2,5 FY69P-65A80 151 2,9 FY69P-80A

100 190 4,4 FY69P-100A125 297 4,4 FY69P-125A150 378 5,7 FY69P-150A200 – – FY69P-200A

Replacement sieve, mesh size 0,5 mm, for size DN 15 ES69Y-15

Replacement sieve, mesh size 0,5 mm, for size DN 20 ES69Y-20

Replacement sieve, mesh size 0,5 mm, for size DN 25 ES69Y-25

Replacement sieve, mesh size 0,5 mm, for size DN 32 ES69Y-32

Replacement sieve, mesh size 0,5 mm, for size DN 40 ES69Y-40

Replacement sieve, mesh size 0,5 mm, for size DN 50 ES69Y-50

Replacement sieve, mesh size 0,5 mm, for size DN 65 ES69Y-65

Replacement sieve, mesh size 0,5 mm, for size DN 80 ES69Y-80

Replacement sieve, mesh size 0,5 mm, for size DN 100 ES69Y-100

Replacement sieve, mesh size 0,5 mm, for size DN 125 ES69Y-125

Replacement sieve, mesh size 0,5 mm, for size DN 150 ES69Y-150

Replacement sieve, mesh size 0,5 mm, for size DN 200 ES69Y-200

Page 436: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-23

Strainers with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

FY71P strainers are used in commercial and industrial applications, as well as for central water supply systems within the limits of their specifications. They protect systems against malfunction and corrosion damage resulting from the ingress of foreign bodies such as welding beads, sealing materials, metal cuttings and rust etc. This extends the life of the downstream system and prevents early failure.

With triple sieve, mesh size approximately 0,5 mm

Spare Parts

Cast steel Y-strainer with flange connections, FY71P

Media Water, oil and compressed air up to 40,0 bar and for steam corresponding to DIN 2401, pressure rating PN 40

Body material cast steel

Body finishing powder coating

Port connection flanges

Max. media temperature 200 oC

Pressure rating PN40

Filter mesh 0,5 mm

Mounting position horizontal or vertical

Additional description • Low flow resistance because of good dynamic flow design of body• Powder coated inside and outside, which is toxicologically and

physiologically safe• Stainless steel construction gives triple sieve good corrosion

resistance• Large strainer mesh surface area provides high dirt acceptance

capacity• Dirt particles or condensate in compressed air systems can be

flushed out with blanking plug removed

DN size Flow capacity Kvs Zeta value Typemm

15 4,9 3,4 FY71P-15B20 8,5 3,5 FY71P-20B32 22,3 2,1 FY71P-32B40 33,5 3,6 FY71P-40B50 61 2,7 FY71P-50B65 107 2,5 FY71P-65B80 151 2,9 FY71P-80B

100 190 4,4 FY71P-100B125 297 4,4 FY71P-125B150 378 5,7 FY71P-150B

Replacement sieve, mesh size 0,5 mm, for size DN 15 ES71Y-15

Replacement sieve, mesh size 0,5 mm, for size DN 20 ES71Y-20

Replacement sieve, mesh size 0,5 mm, for size DN 32 ES71Y-32

Replacement sieve, mesh size 0,5 mm, for size DN 40 ES71Y-40

Replacement sieve, mesh size 0,5 mm, for size DN 50 ES71Y-50

Replacement sieve, mesh size 0,5 mm, for size DN 65 ES71Y-65

Replacement sieve, mesh size 0,5 mm, for size DN 80 ES71Y-80

Replacement sieve, mesh size 0,5 mm, for size DN 100 ES71Y-100

Replacement sieve, mesh size 0,5 mm, for size DN 125 ES71Y-125

Replacement sieve, mesh size 0,5 mm, for size DN 150 ES71Y-150

Page 437: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-24

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Filter Combinations

HS10S combination water supply units integrate a non return valve with test point, reverse rinsing fine filter, pressure reducing valve and shutoff valve in one appliance. They ensure a continuous supply of filtered water. The fine filter stops the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The non-return valve protects the mains water system against back pressure, back flow and back syphonage of health threatening liquids. The pressure reducing valve prevents overpressure damage and reduces water consumption. All individual units correspond to the requirements of current DIN/DVGW specifications. Technical features of each unit also apply to the combination assembly.

Threaded male connections, filter mesh size 100 micron

Combination water supply unit, HS10S

Approvals DIN/DVGW-certified

Media Water• The filter is constructed for drinking water installations. In case of

a process water application the filter has to be proven individually.

Filter type reverse rinsing

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Port connection external threads

Filter mesh 100 micron

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Integrated non-return device yes

Reverse rinsing with filtered water

yes

Mounting position horizontal

Additional description • Double Spin Technology for connection sizes 1/2" to 11/4" - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Especially compact because pressure reducing valve, fine filter, non return valve and shutoff valve are combined in one unit

• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when next manual reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted

Portdiameter

DN size Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

1/2 15 40 PN16 2,7 • HS10S-1/2AA3/4 20 40 PN16 3,2 • HS10S-3/4AA

1 25 40 PN16 7,6 • HS10S-1AA1 1/4 32 40 PN16 8,9 • HS10S-11/4AA1 1/2 40 40 PN16 12,6 • HS10S-11/2AA

2 50 40 PN16 13 • HS10S-2AA

Page 438: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-25

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Red bronze filter bowl, threaded male connections, filter mesh size 100 micron

Accessories

Portdiameter

DN size Max. mediatemperature

Pressurerating

Flow capacityKvs

Transparantstrainer chamber

Type

inch mm oC

1/2 15 70 PN25 2,7 – HS10S-1/2AAM3/4 20 70 PN25 3,2 – HS10S-3/4AAM

1 25 70 PN25 7,6 – HS10S-1AAM1 1/4 32 70 PN25 8,9 – HS10S-11/4AAM1 1/2 40 70 PN25 12,6 – HS10S-11/2AAM

2 50 70 PN25 13 – HS10S-2AAM

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Filter insert complete. Filter meshes 20 micron. Connection size 1/2" - 3/4" AF11S-1/2B

Filter insert complete. Filter meshes 50 micron. Connection size 1/2" - 3/4" AF11S-1/2C

Filter insert complete. Filter meshes 200 micron. Connection size 1/2" - 3/4" AF11S-1/2D

Filter insert complete. Filter meshes 300 micron. Connection size 1/2" - 3/4" AF11S-1/2E

Filter insert complete. Filter meshes 500 micron. Connection size 1/2" - 3/4" AF11S-1/2F

Filter insert complete. Filter meshes 20 micron. Connection size 1" - 11/4" AF11S-1B

Filter insert complete. Filter meshes 50 micron. Connection size 1" - 11/4" AF11S-1C

Filter insert complete. Filter meshes 200 micron. Connection size 1" - 11/4" AF11S-1D

Filter insert complete. Filter meshes 300 micron. Connection size 1" - 11/4" AF11S-1E

Filter insert complete. Filter meshes 500 micron. Connection size 1" - 11/4" AF11S-1F

Filter insert complete. Filter meshes 20 micron. Connection size 11/2" - 2" AF11S-11/2B

Filter insert complete. Filter meshes 50 micron. Connection size 11/2" - 2" AF11S-11/2C

Filter insert complete. Filter meshes 200 micron. Connection size 11/2" - 2" AF11S-11/2D

Filter insert complete. Filter meshes 300 micron. Connection size 11/2" - 2" AF11S-11/2E

Filter insert complete. Filter meshes 500 micron. Connection size 11/2" - 2" AF11S-11/2F

Filter insert complete, filter mesh size 20 micron. Connection size 1/2" - 3/4" AF11DS-1/2B

Filter insert complete, filter mesh size 50 micron. Connection size 1/2" - 3/4" AF11DS-1/2C

Filter insert complete, filter mesh size 200 micron. Connection size 1/2" - 3/4" AF11DS-1/2D

Filter insert complete, filter mesh size 300 micron. Connection size 1/2" - 3/4" AF11DS-1/2E

Filter insert complete, filter mesh size 500 micron. Connection size 1/2" - 3/4" AF11DS-1/2F

Filter insert complete, filter mesh size 20 micron. Connection size 1" - 11/4" AF11DS-1B

Filter insert complete, filter mesh size 50 micron. Connection size 1" - 11/4" AF11DS-1C

Filter insert complete, filter mesh size 200 micron. Connection size 1" - 11/4" AF11DS-1D

Filter insert complete, filter mesh size 300 micron. Connection size 1" - 11/4" AF11DS-1E

Filter insert complete, filter mesh size 500 micron. Connection size 1" - 11/4" AF11DS-1F

Page 439: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-26

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Spare Parts

HS74CA combination water supply units integrate pressure reducing valve, reverse rinsing fine filter, non-return valve, and automatic reverse rinsing actuator in one appliance. Therefore, these units comprise all armatures needed for private water supply systems and ensure continuous supply of filtered water. The pressure reducing valve prevents overpressure damage and reduces water consumption. The fine filter stops the ingress of foreign bodies. The non-return valve protects the mains water system. The automatic reverse rinsing actuator operates with batteries, therefore, there is no need for a bus bar in the area of the water supply. It is responsible for the fully automatic cleaning of the fine filter. All individual units correspond to the requirements of current DIN/DVGW specifications.

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 25 bar

M38K-A25

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M38K-A16

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar

M38K-A10

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FA-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FA-1A

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FA-11/2

Filter insert complete, filter mesh size 100 micron, for sizes R 1/2 - R 3/4 AF11S-1/2A

Filter insert complete, filter mesh size 100 micron, for sizes R 1 - R 1 1/4 AF11S-1A

Filter insert complete, filter mesh size 100 micron, for sizes R 1 1/2 - R 2 AF11S-11/2A

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes R 1/2 - R 3/4

AF11DS-1/2A

Filter insert complete for filters with Double Spin Technology, filter mesh size 100 micron, for sizes R 1

AF11DS-1A

Clear filter bowl complete for sizes R 1/2 - R 1 1/4 KF11S-1A

Clear filter bowl complete for sizes R 1 1/2 - R 2 KF11S-11/2A

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1/2 - R 1 1/4

FT09RS-1A

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1 1/2 + R 2

FT09RS-11/2A

Ball valve complete KH11S-1A

Drain connector AA76-1/2A

Double ring wrench for removal of spring bonnet and filter bowl, for R 1/2 + R 3/4 ZR10K-3/4

Double ring wrench for removal of spring bonnet and filter bowl, for R 1 + R 1 1/4 ZR10K-1

Double ring wrench for removal of spring bonnet and filter bowl, for R 1 1/2 + R 2 ZR10K-11/2

Fully automatic combination water supply unit with automatic reverse rinsing actuator, HS74CA

Approvals DIN/DVGW for filter combination FK74C and for non-return valve RV277

Media water

Filter type reverse rinsing

Body material synthetic material

Spring bonnet material synthetic material

Port connection external threads

Max. media temperature 30 oC

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Transparant strainer chamber yes

Page 440: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-27

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Filter mesh size 100 micron

Filter mesh size 50 micron

Filter mesh size 200 micron

Spare Parts

Balanced seat design yes

Integrated non-return device yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Inlet pressure compensation - fluctuating inlet pressures do not influence outlet pressure

• Battery-operated automatic reverse rinsing actuator, acoustic signal when battery is running low; reverse rinsing can also be activated manually

• Patented reverse rinsing system - fast and thorough cleaning of the filter with small amount of water

• Filtered water supplied even during reverse rinsing• Owing to its short construction length it is also suitable for limited

space

Port diameter (inch) DN size (mm) Flow capacity Kvs Filter mesh (micron) Type3/4 20 5,5 100 HS74CA-3/4AA

1 25 6 100 HS74CA-1AA1 1/4 32 6,5 100 HS74CA-11/4AA

Port diameter (inch) DN size (mm) Flow capacity Kvs Filter mesh (micron) Type3/4 20 5,5 50 HS74CA-3/4AC

1 25 6 50 HS74CA-1AC1 1/4 32 6,5 50 HS74CA-11/4AC

Port diameter (inch) DN size (mm) Flow capacity Kvs Filter mesh (micron) Type3/4 20 5,5 200 HS74CA-3/4AD

1 25 6 200 HS74CA-1AD1 1/4 32 6,5 200 HS74CA-11/4AD

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M07M-A16

Valve insert complete D06FA-1B

Filter insert complete, filter mesh size 100 micron AF74-1A

Filter insert complete, filter mesh size 50 micron AF74-1C

Filter insert complete, filter mesh size 200 micron AF74-1D

Clear filter bowl complete KF74-1A

Non-return valve cartridge, for R 3/4 inch 2110200

Non-return valve cartridge, for R 1 inch 2110400

Non-return valve cartridge, for R 1 1/4 inch 2110500

Automatic reverse rinsing actuator Z74S-A

Page 441: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-28

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The filter combinations comprise reverse rinsing filter and pressure reducing valve in one appliance. They ensure a continuous supply of filtered water. The fine filter stops the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The pressure reducing valve prevents pressure damage and reduces water consumptionThe filter combinations are fitted in systems where a pressure reducing valve is required. Both horizontal and vertical installation is possible.

With rotatable connector piece, filter mesh size 95/110 micron

Filter combination with pressure reducing valve and reverse rinsing fine filter, FK74CS

Approvals DVGW-certified

Media Water• The filter is constructed for drinking water installations. In case of

a process water application the filter has to be proven individually. For maintaining the measuring accuracy of the manometer, a continuous maximum pressure load of 12.0 bar is permitted.

Filter type reverse rinsing

Body material synthetic material

Spring bonnet material synthetic material

Port connection external threads

Max. media temperature 30 oC

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Transparant strainer chamber yes

Balanced seat design yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Integral pressure reducing valve with balanced seat• Inlet pressure compensation - fluctuating inlet pressures do not

influence outlet pressure• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates time when next reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted• Large filter surface• Shock resistant clear synthetic material filter bowl - enables easy

checking of filter contamination• Filter insert fully replaceable• Standardised discharge connection• Meets KTW recommendations for potable water

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 4,5 95/110 FK74CS-1/2AA3/4 20 5,8 95/110 FK74CS-3/4AA

1 25 6,2 95/110 FK74CS-1AA1 1/4 32 6,5 95/110 FK74CS-11/4AA

Page 442: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-29

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

With rotatable connector piece, filter mesh size 50 micron

With rotatable connector piece, filter mesh size 200 micron

Accessories

Spare Parts

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 4,5 50 FK74CS-1/2AC3/4 20 5,8 50 FK74CS-3/4AC

1 25 6,2 50 FK74CS-1AC1 1/4 32 6,5 50 FK74CS-11/4AC

Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

1/2 15 4,5 200 FK74CS-1/2AD3/4 20 5,8 200 FK74CS-3/4AD

1 25 6,2 200 FK74CS-1AD1 1/4 32 6,5 200 FK74CS-11/4AD

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1/2"

DA74CS-1/2A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 3/4"

DA74C-3/4A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1"

DA74C-1A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 11/4"

DA74C-11/4A

Automatic reverse rinsing actuator for automatic filter cleaning at presettable intervals

Z74S-AN

Valve insert complete D06FA-1B

Filter insert complete, filter mesh size 95/110 micron AF74-1A

Filter insert complete, filter mesh size 50 micron AF74-1C

Filter insert complete, filter mesh size 200 micron AF74-1D

Clear filter bowl complete KF74CS-1A

Pressure gauge, rear connection thread G1/4", Range:0 - 16 bar M74CS-A16

Wrench for removing filter bowl and spring bonnet ZR74CS

Page 443: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-30

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The FK76CS filter combinations comprise reverse rinsing filter and pressure reducing valve in one appliance. They ensure a continuous supply of filtered water. The fine filter stops the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The pressure reducing valve prevents pressure damage and reduces water consumption. The integrated appliances correspond to the requirements of the current DIN/DVGW specification. Features of the individual components also apply for the combination unit. FK76CS filter combinations are especially suited for the retrofitting and modernisation of existing water supply systems in buildings. The rotatable connector piece permits installation even where space is limited. Installation can be in either horiziontal or vertical pipework.

Threaded male connections, filter mesh size 100 micron

Reverse rinsing filter combination with rotatable connector flange, FK76CS

Approvals DVGW-approval requested

Media Water

Filter type reverse rinsing

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Port connection external threads

Max. media temperature 40 oC

Pressure rating PN16

Filter mesh 100 micron

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Transparant strainer chamber yes

Balanced seat design yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description Double Spin Technology - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Balanced seat valve• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when next manual reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted

Port diameter DN size Flow capacity Kvs Typeinch mm

3/4 20 5,4 FK76CS-3/4AA1 25 6 FK76CS-1AA

1 1/4 32 9 FK76CS-114AA

Page 444: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-31

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Spare Parts

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure

FT09RS-1A

Intermediate connector for conversion of the fine filters with rotatable connector pieces (1 1/4" and 1 1/2") into retrofit FKN76CS filter combinations (Converts 63 mm hole centres to 45 mm hole centres)

ZA76C

Inlet check valve. Connection size 3/4" RV277-3/4A

Inlet check valve. Connection size 1" RV277-1A

Inlet check valve. Connection size 11/4" RV277-11/4A

Threaded male connection, connection size 3/4" VST06-3/4A

Threaded male connection, connection size 1" VST06-1A

Threaded male connection, connection size 11/4" VST06-11/4A

Solder union connection, connection size 3/4" VST06-3/4B

Solder union connection, connection size 1" VST06-1B

Solder union connection, connection size 11/4" VST06-11/4B

Filter insert complete. Available with filter meshes 100 micron, for filters with Double Spin Technology

AF11DS-1A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M07M-A16

Filter insert complete for filters with double spin technology, filter mesh size 100 micron

AF11DS-1A

Valve insert complete (without filter) D06FA-1A

Clear filter bowl complete KF11S-1A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removing filter bowl and spring bonnet ZR10K-1

Page 445: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-32

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The filter combinations comprise reverse rinsing filter and pressure reducing valve in one appliance. They ensure a continuous supply of filtered water. The fine filter stops the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The pressure reducing valve prevents pressure damage and reduces water consumptionThe filter combinations are fitted in systems where a pressure reducing valve is required. Both horizontal and vertical installation is possible.

Retrofit filter combination with pressure reducing valve and reverse rinsing fine filter, FKN74CS

Approvals DVGW-certified with rotatable connector piece

Media Water• The filter is constructed for drinking water installations. In case of

a process water application the filter has to be proven individually. For maintaining the measuring accuracy of the manometer, a continuous maximum pressure load of 12.0 bar is permitted.

Body material synthetic material

Spring bonnet material synthetic material

Max. media temperature 30 oC

Pressure rating PN16

Flow capacity Kvs 6,2

Pressure setpoint range 1,5 ... 6 bar

Transparant strainer chamber yes

Balanced seat design yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Integral pressure reducing valve with balanced seat• Inlet pressure compensation - fluctuating inlet pressures do not

influence outlet pressure• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates time when next reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted• Large filter surface• Shock resistant clear synthetic material filter bowl - enables easy

checking of filter contamination• Filter insert fully replaceable• Standardised discharge connection• Meets KTW recommendations for potable water

Page 446: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-33

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Retrofit version without rotatable connector piece, filter mesh size 95/110 micron

Retrofit version without rotatable connector piece, filter mesh size 50 micron

Accessories

Spare Parts

Filter mesh Typemicron

95/110 FKN74CS-1A

Filter mesh Typemicron

50 FKN74CS-1C

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1/2"

DA74CS-1/2A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 3/4"

DA74C-3/4A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 1"

DA74C-1A

Rotatable connector piece for connection of retrofit filters and filter combinations; for connection size 11/4"

DA74C-11/4A

Automatic reverse rinsing actuator for automatic filter cleaning at presettable intervals

Z74S-AN

Valve insert complete D06FA-1B

Filter insert complete, filter mesh size 95/110 micron AF74-1A

Filter insert complete, filter mesh size 50 micron AF74-1C

Filter insert complete, filter mesh size 200 micron AF74-1D

Clear filter bowl complete KF74CS-1A

Pressure gauge, rear connection thread G1/4", Range:0 - 16 bar M74CS-A16

Wrench for removing filter bowl and spring bonnet ZR74CS

Page 447: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-34

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The FKN76CS filter combinations comprise reverse rinsing filter and pressure reducing valve in one appliance. They ensure a continuous supply of filtered water. The fine filter stops the ingress of foreign bodies, for example rust particles, strands of hemp and grains of sand. The pressure reducing valve prevents pressure damage and reduces water consumption. The integrated appliances correspond to the requirements of the current DIN/DVGW specification. Features of the individual components also apply for the combination unit. FKN76CS filter combinations are especially suited for the retrofitting and modernisation of existing water supply systems in buildings where an existing filter is to be repalaced. The existing connectors can be reused. Where connections dimensions are different, an adapter can be used.

Retrofit reverse rinsing filter combination for connector flange, FKN76CS

Approvals DVGW-approval requested

Media Water

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Port diameter 1 inch

DN size 25 mm

Max. media temperature 40 oC

Pressure rating PN16

Flow capacity Kvs 6

Filter mesh 100 micron

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Transparant strainer chamber yes

Balanced seat design yes

Reverse rinsing with filtered water

yes

Mounting position horizontal or vertical

Additional description • Double Spin Technology - Cartridge with external rotor enabling simultaneous cleaning in lower and upper filter areas, visual function check possible

• Balanced seat valve• Filtered water supplied even during reverse rinsing• Patented reverse rinsing system - fast and thorough cleaning of

the filter with small amount of water• Memory ring indicates when next manual reverse rinsing is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted

Page 448: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-35

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Filter mesh size 100 micron

Accessories

Spare Parts

TypeFKN76CS-1A

Rotatable connector piece in connection size R 3/4 DA74C-3/4A

Rotatable connector piece in connection size R 1 DA74C-1A

Rotatable connector piece in connection size R 1 1/4 DA74C-11/4A

Intermediate connector for conversion of fine filters with rotatable connector pieces (R 1 1/4 and R 1 1/2) e.g. Cillit type 77 into retrofit FKN 76 CS filter combinations

ZA76C-11/4

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure

FT09RS-1A

Inlet check valve, connection size 3/4" RV277-3/4A

Inlet check valve, connection size 1" RV277-1A

Inlet check valve, connection size 11/4" RV277-11/4A

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar

M07M-A16

Filter insert complete for filters with double spin technology, filter mesh size 100 micron

AF11DS-1A

Valve insert complete (without filter) D06FA-1A

Clear filter bowl complete KF11S-1A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removing filter bowl and spring bonnet ZR10K-1

Page 449: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-36

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16FK06 rinsable filter combinations ensure a continuous supply of filtered water. They prevent the ingress of foreign matter such as particles of rust, strands of hemp and grains of sand. The accumulation of foreign particles in the base of the filter bowl can be easily removed by reverse rinsing. The pressure reducing valve prevents overpressure damage and reduces the water consumption. The appliances correspond to DIN/DVGW requirements. The compact overall dimensions enable the filter combination to be fitted even where space is limited.

Threaded male connections, filter mesh size 100 micron

Threaded male connections, filter mesh size 100 micron, filter bowl of dezincification resistant brass

Accessories

Spare Parts

Rinseable filter combination, MiniPlus-FK06

Filter type rinsable

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Port connection external threads

Max. media temperature 40 oC

Pressure rating PN16

Filter mesh 100 micron

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Balanced seat design yes

Mounting position horizontal

Additional description • A turn on the adjuster knob is all that is required for setting• The setting is directly readable from the setting indicator• Filtered water supply maintained even during rinsing• Inlet pressure balancing - fluctuating inlet pressure does not

influence outlet pressure• Filter and complete filter bowl are replaceable

Port diameter (inch) DN size (mm) Flow capacity Kvs Transparant strainer chamber Type1/2 15 2,5 • FK06-1/2AA3/4 20 2,9 • FK06-3/4AA

1 25 6 • FK06-1AA1 1/4 32 6,2 • FK06-11/4AA

Port diameter (inch) DN size (mm) Flow capacity Kvs Transparant strainer chamber Type1/2 15 2,5 – FK06-1/2AAM3/4 20 2,9 – FK06-3/4AAM

1 25 6 – FK06-1AAM1 1/4 32 6,2 – FK06-11/4AAM

Double ring wrench for removing of spring bonnet ZR06K

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 4 bar M07M-A4

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar M07M-A10

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 16 bar M07M-A16

Inlet check valve _RV277

Valve cartridge complete (without filter insert) for sizes R 1/2 + R 3/4 D06FA-1/2

Valve cartridge complete (without filter insert) for size R 1 + R 1 1/4 D06FA-1B

Exchange filter insert complete for size R 1/2 + R 3/4 AS06-1/2A

Exchange filter insert complete for sizes R 1 + R 1 1/4 AS06-1A

Clear filter bowl complete with filter and carrier body, for size R 1/2 + R3/4 KF06-1/2A

Clear filter bowl complete with filter and carrier body, for size R 1 + R 1 1/4 KF06-1A

Double ring wrench for removing of filter bowl ZR06F

Page 450: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-37

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

The FK09S reverse-rinsable filter combination integrates a fine filter and a pressure reducing valve in one appliance. It guarantees a continuous filtered water supply. The fine filter prevents the entry of foreign matter, such as rust particles, hemp remains and grains of sand. The pressure reducing valve prevents over pressure damage, minimises flow noises and reduces water consumption. The integrated appliances comply with DIN/DVGW requirements. Features of the separate individual units also apply for the filter combination.

Threaded male connections, filter mesh size 100 micron

Threaded male connections, filter mesh size 50 micron

Reverse rinsing filter combination, FK09S

Media Water

Filter type reverse rinsing

Body material brass, dezincification resistant

Spring bonnet material synthetic material

Max. media temperature 40 oC

Pressure rating PN16

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Transparant strainer chamber yes

Balanced seat design yes

Reverse rinsing with filtered water

yes

Mounting position horizontal

Additional description • Balanced single-seat valve• Supply of filtered water is maintained during reverse rinsing cycle• Patented reverse rinsing system - fast and thorough cleaning of

the filter with minimum water consumption• Memory-ring indicates when the next manual reverse rinsing cycle

is due• Automatic reverse rinsing actuator with bayonet connector can be

retrofitted

Port connection Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

external threads 1/2 15 2,5 100 FK09S-1/2AAexternal threads 3/4 20 3 100 FK09S-3/4AAexternal threads 1 25 5,8 100 FK09S-1AAexternal threads 1 1/4 32 5,9 100 FK09S-11/4AAexternal threads 1 1/2 40 12 100 FK09S-11/2AAexternal threads 2 50 11,6 100 FK09S-2AA

Port connection Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

external threads 1/2 15 2,5 50 FK09S-1/2ACexternal threads 3/4 20 3 50 FK09S-3/4ACexternal threads 1 25 5,8 50 FK09S-1ACexternal threads 1 1/4 32 5,9 50 FK09S-11/4ACexternal threads 1 1/2 40 12 50 FK09S-11/2ACexternal threads 2 50 11,6 50 FK09S-2AC

Page 451: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-38

Filter Combinations

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16 Soldered connections, filter mesh size 100 micron

Without connections, filter mesh size 100 micron, DN is based on connection size of tailpiece

Accessories

Port connection Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

soldering 1/2 15 2,5 50 FK09S-1/2BAsoldering 3/4 20 3 50 FK09S-3/4BAsoldering 1 25 5,8 50 FK09S-1BAsoldering 1 1/4 32 5,9 50 FK09S-11/4BAsoldering 1 1/2 40 12 50 FK09S-11/2BAsoldering 2 50 11,6 50 FK09S-2BA

Port connection Port diameter DN size Flow capacity Kvs Filter mesh Typeinch mm micron

– 1/2 15 2,5 50 FK09S-1/2EA– 3/4 20 3 50 FK09S-3/4EA– 1 25 5,8 50 FK09S-1EA– 1 1/4 32 5,9 50 FK09S-11/4EA– 1 1/2 40 12 50 FK09S-11/2EA– 2 50 11,6 50 FK09S-2EA

Automatic reverse rinsing actuator for automatic filter cleaning, 230 V, 50/60 Hz, 10 W, IP 55, with electrical plug

Z11S-A

Automatic reverse rinsing actuator for automatic filter cleaning, 24 V, 50/60 Hz, 10 W, IP 55, without electrical plug

Z11S-B

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1/2 - R 1 1/4

FT09RS-1A

Red bronze filter bowl for temperatures up to 70 oC and up to 25 bar operating pressure, for R 1 1/2 + R 2

FT09RS-11/2A

Inlet check valve, connection size 1/2 RV277-1/2A

Inlet check valve, connection size 3/4" RV277-3/4A

Inlet check valve, connection size 1" RV277-1A

Inlet check valve, connection size 11/4" RV277-11/4A

Inlet check valve, connection size 11/2" RV277-11/2A

Inlet check valve, connection size 2" RV277-2A

Threaded male connection, connection size 1/2" VST06-1/2A

Threaded male connection, connection size 3/4" VST06-3/4A

Threaded male connection, connection size 1" VST06-1A

Threaded male connection, connection size 11/4" VST06-11/4A

Threaded male connection, connection size 11/2" VST06-11/2A

Threaded male connection, connection size 2" VST06-2A

Solder union connection, connection size 1/2" VST06-1/2B

Solder union connection, connection size 3/4" VST06-3/4B

Solder union connection, connection size 1" VST06-1B

Solder union connection, connection size 11/4" VST06-11/4B

Solder union connection, connection size 11/2" VST06-11/2B

Solder union connection, connection size 2" VST06-2B

Page 452: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-39

Filter Combinations

16

17

18

19

20

21

22

24

23

25

26

27

28

Spare Parts

Valve insert complete (without filter) for sizes R 1/2 + R 3/4 D06FA-1/2

Valve insert complete (without filter) for sizes R 1 + R 1 1/4 D06FA-1B

Valve insert complete (without filter) for sizes R 1 1/2 + R 2 D06FA-11/2

Pressure gauge with housing diameter 50 mm, connection thread G 1/4, range 0 - 10 bar

M07M-A10

Filter insert complete, filter mesh size 100 micron, for sizes R 1/2 - R 1 1/4 AF11S-1A

Filter insert complete, filter mesh size 20 micron, for sizes R 1/2 - R 1 1/4 AF11S-1B

Filter insert complete, filter mesh size 50 micron, for sizes R 1/2 - R 1 1/4 AF11S-1C

Filter insert complete, filter mesh size 200 micron, for sizes R 1/2 - R 1 1/4 AF11S-1D

Filter insert complete, filter mesh size 300 micron, for sizes R 1/2 - R 1 1/4 AF11S-1E

Filter insert complete, filter mesh size 500 micron, for sizes R 1/2 - R 1 1/4 AF11S-1F

Filter insert complete, filter mesh size 100 micron, for sizes R 1 1/2 - R 2 AF11S-11/2A

Filter insert complete, filter mesh size 20 micron, for sizes R 1 1/2 - R 2 AF11S-11/2B

Filter insert complete, filter mesh size 50 micron, for sizes R 1 1/2 - R 2 AF11S-11/2C

Filter insert complete, filter mesh size 200 micron, for sizes R 1 1/2 - R 2 AF11S-11/2D

Filter insert complete, filter mesh size 300 micron, for sizes R 1 1/2 - R 2 AF11S-11/2E

Filter insert complete, filter mesh size 500 micron, for sizes R 1 1/2 - R 2 AF11S-11/2F

Clear filter bowl complete for sizes R 1/2 - R 1 1/4 KF11S-1A

Clear filter bowl complete for sizes R 1 1/2 - R 2 KF11S-11/2A

Ball valve complete KH11S-1A

Drain connection AA76-1/2A

Double ring wrench for removal of spring bonnet and filter bowl, for R 1/2 - R 1 1/4 ZR10K-1

Double ring wrench for removal of spring bonnet and filter bowl, for R 1 1/2 + R 2 ZR10K-11/2

Page 453: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-40

Actuators for Filters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Actuators for Filters

The Z74A automatic reverse rinsing actuator provides fully automatic cleaning for Honeywell F74C reverse rinsing filters and FK74C filter combinations. The reverse rinsing intervals are adjustable in sixteen steps between four minutes and three months. The Z74A has an emergency running function on power failure and offers the possibility of manual operation of the reverse rinsing function (only when batteries are fitted). Connection options are available for differential pressure, remote control and remote monitoring.For fully automatic reverse rinsing of Honeywell F74C respec. FN74C filters and FK74C respec. FKN74C filter combinations

For filters and filter combinations HS10S, F76CS, FK76CS, FKN76CS, FN76CS, F74C, FK74C, FKN74C, FN74C

Reverse rinsing actuator for fully automatic filter cleaning, Z74A

Approvals CE

Body material synthetic material

Max. media temperature 70 oC

Battery life Appr. 3 years

Cable length 1,5 m

Product description 230 V, 50/60 Hz, 10 W

Additional description • Four LR6-1.5 V-Mignon/AA size alkali-manganese batteries(Batteries are not supplied with the appliance)

• Can be set to 16 different reverse rinsing intervals between 4 minutes and 3 months

• Set during manufacture to 45 day interval• Automatic battery run-on if mains supply fails (Batteries are not

necessary if automatic run-on in the event of power failure is not required. When batteries are fitted, the appliance should not be left unplugged for long periods)

• Bayonet connection enables fitting without tools• Manufactured with integral electrical suppression• Manufactured with integral electrical suppression• Sprayed water protection to IP 55• Additional PG 9 cable entry for connection of remote opera-tion,

remote monitoring or differential pressure control

TypeZ74A-A

Page 454: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-41

Actuators for Filters

16

17

18

19

20

21

22

24

23

25

26

27

28

The Z74S automatic reverse rinsing actuator provides fully automatic cleaning for all Honeywell Braukmann reverse rinsing filters, filter combinations and water supply units with bayonet connection. A bayonet connection enables fitting the Z74S without tools. The reverse rinsing interval is set permanently to 45 days. The Z74S automatic reverse rinsing actuator has a safety function which prevents the ball valve from opening when the battery voltage is too low and notifies this through an acoustic signal for approx. 2 days.Use reverse rinsing actuator Z74S for filters and filtercombinations HS10S, F76CS, FK76CS, FKN76CS, FN76CS, F74C, FK74C, FKN74C, FN74C and FN09S.

With bayonet connection

The Z74S-AN automatic reverse rinsing actuator provides fully automatic cleaning for Honeywell filters F74CS, FN74CS and filter combinations FK74CS, FKN74CS. A bayonet connection enables fitting the Z74S-AN without tools.The reverse rinsing interval can be set to 8 different intervals

With bayonet connection

Reverse rinsing actuator for fully automatic filter cleaning, Z74S

Approvals CE

Media Water

Body material synthetic material

Max. media temperature 40 oC

Battery life Appr. 1 years

Additional description Three LR6-1.5 V-Mignon/AA size alkali-manganese batteries (Batteries are not supplied with the appliance)

• Bayonet connection enables fitting without tools• With locking mechanism which prevents the ball valve from

opening, if the battery voltage is too low to carry out the closing• Set during manufacture to 45 day interval• Battery operation• Manufactured with integral electrical suppression

TypeZ74S-A

Reverse rinsing actuator for Honeywell filters F74CS, FN74CS, FK74CS and FKN74CS

Approvals CE

Media Water

Body material synthetic material

Max. media temperature 30 oC

Product description Reverse rinsing interval adjustable to 1hour / 1day / 6days / 15days / 30days / 45days / 2months / 3months

Additional description • Bayonet connection enables fitting without tools• 8 reverse rinsing intervalls• Battery operation• Manufactured with integral electrical suppression

TypeZ74S-AN

Page 455: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

19-42 http://products.ecc.emea.honeywell.com/europe

Page 456: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow Preventers, Non-return Valves, residential/industrial Page

Backflow Preventers 20-2Backflow Preventers with flanges 20-15Non-return Valves with flanges 20-22

Page 457: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-2

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow Preventers

Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems" and correspond to DIN1988 part 4 type 1 construction. Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors can be used to provide protection up to and including liquid category 3 (slightly toxic substances). Mechanical disconnectors therefore offer better protection than check valves.

With female threaded union connectors, 0,5 bar opening pressure

With female threaded union connectors, 1,0 bar opening pressure

With female threaded union connectors, 1,5 bar opening pressure (standard pattern)

With female threaded union connectors, 2,0 bar opening pressure

Mechanical disconnector with union connectors direct actuated, GA type according to EN1717 / type 1 according to DIN1988 part 4, R295

Media Cold water

Liquid category (EN1717) class 3

Body material red bronze RG5

Spring bonnet material synthetic material

Port connection internal threads

Max. media temperature 40 oC

Pressure rating PN10

Mounting position horizontal

Additional description • Low pressure drop and high flow rate • Optimum protection of the drinking water supply system • Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off position visually indicated on the spring bonnet • Compact construction

Port diameter (inch) DN size (mm) Set pressure (bar) Minimum inlet pressure (bar) Flow capacity Kvs TypeRp 1/2 15 0,5 1,5 4,5 R295-1/2ARp 3/4 20 0,5 1,5 6 R295-3/4A

Rp 1 25 0,5 1,5 8 R295-1ARp 1 1/4 32 0,5 1,5 13 R295-11/4ARp 1 1/2 40 0,5 1,5 18 R295-11/2A

Rp 2 50 0,5 1,5 27 R295-2A

Port diameter (inch) DN size (mm) Set pressure (bar) Minimum inlet pressure (bar) Flow capacity Kvs TypeRp 1/2 15 1 2 4,5 R295-1/2BRp 3/4 20 1 2 6 R295-3/4B

Rp 1 25 1 2 8 R295-1BRp 1 1/4 32 1 2 13 R295-11/4BRp 1 1/2 40 1 2 18 R295-11/2B

Rp 2 50 1 2 27 R295-2B

Port diameter (inch) DN size (mm) Set pressure (bar) Minimum inlet pressure (bar) Flow capacity Kvs TypeRp 1/2 15 1,5 2,5 4,5 R295-1/2CRp 3/4 20 1,5 2,5 6 R295-3/4C

Rp 1 25 1,5 2,5 8 R295-1CRp 1 1/4 32 1,5 2,5 13 R295-11/4CRp 1 1/2 40 1,5 2,5 18 R295-11/2C

Rp 2 50 1,5 2,5 27 R295-2C

Port diameter (inch) DN size (mm) Set pressure (bar) Minimum inlet pressure (bar) Flow capacity Kvs TypeRp 1/2 15 2 3 4,5 R295-1/2DRp 3/4 20 2 3 6 R295-3/4D

Rp 1 25 2 3 8 R295-1DRp 1 1/4 32 2 3 13 R295-11/4DRp 1 1/2 40 2 3 18 R295-11/2D

Rp 2 50 2 3 27 R295-2D

Page 458: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-3

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

Spare Parts

Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems" and correspond to DIN1988 part 4 type 2 construction. Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors of this type can be used to provide protection up to and including liquid category 4 (toxic, very toxic, carcinogenic and radioactive substances).

With female threaded union connectors, differential pressure 0,5 bar, self-adjusting

Spare Parts

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Mechanical disconnector hydraulic actuated, GB type according to EN1717/ type 2 according to DIN1988 part 4, R295H

Media Water

Liquid category (EN1717) class 4

Body material red bronze RG5

Spring bonnet material synthetic material

Port connection internal threads

Max. media temperature 40 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimum protection of the drinking water supply system • Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off position visually indicated on the spring bonnet • Compact construction• Standardised discharge connection

Port diameter DN size Flow capacity Kvs Typeinch mm

Rp 1/2 15 2,5 R295H-1/2ARp 3/4 20 3,5 R295H-3/4A

Rp 1 25 4 R295H-1ARp 1 1/4 32 10 R295H-11/4ARp 1 1/2 40 14 R295H-11/2A

Rp 2 50 16 R295H-2A

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07K-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07K-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07K-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07K-A25

Page 459: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-4

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems". Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors of this type can be used to provide protection up to and including liquid category 4 (toxic, very toxic, carcinogenic and radioactive substances). The changeover from shutoff to flow positions can be by means of an hydraulic or electrical/electronic actuator.

With female threaded union connectors, opening pressure 0,5 bar

With female threaded union connectors, opening pressure 1,0 bar (standard pattern)

With female threaded union connectors, opening pressure 1,5 bar

Mechanical disconnector electrically actuated, GB type according to EN 1717/ type 2 according to DIN1988 part 4, R295SA

Media Cold water

Power supply 230V 50Hz

Liquid category (EN1717) class 4

Body material red bronze RG5

Spring bonnet material synthetic material

Port connection internal threads

Max. media temperature 40 oC

Pressure rating PN10

Mounting position horizontal

Additional description • Optimum protection of the drinking water supply system • Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off condition visually indicated on the spring bonnet • Compact construction • Standardised discharge connection

Port diameter DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typeinch mm bar bar

Rp 1/2 15 0,5 1,5 4,5 R295SA-1/2ARp 3/4 20 0,5 1,5 6 R295SA-3/4A

Rp 1 25 0,5 1,5 8 R295SA-1ARp 1 1/4 32 0,5 1,5 13 R295SA-11/4ARp 1 1/2 40 0,5 1,5 18 R295SA-11/2A

Rp 2 50 0,5 1,5 27 R295SA-2A

Port diameter DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typeinch mm bar bar

Rp 1/2 15 1 2 4,5 R295SA-1/2BRp 3/4 20 1 2 6 R295SA-3/4B

Rp 1 25 1 2 8 R295SA-1BRp 1 1/4 32 1 2 13 R295SA-11/4BRp 1 1/2 40 1 2 18 R295SA-11/2B

Rp 2 50 1 2 27 R295SA-2B

Port diameter DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typeinch mm bar bar

Rp 1/2 15 1,5 2,5 4,5 R295SA-1/2CRp 3/4 20 1,5 2,5 6 R295SA-3/4C

Rp 1 25 1,5 2,5 8 R295SA-1CRp 1 1/4 32 1,5 2,5 13 R295SA-11/4CRp 1 1/2 40 1,5 2,5 18 R295SA-11/2C

Rp 2 50 1,5 2,5 27 R295SA-2C

Page 460: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-5

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

With female threaded union connectors, opening pressure 2,0 bar

Spare Parts

Backflow preventers are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 3 to EN 1717 are protected.

Standard version with threaded connections

Port diameter DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typeinch mm bar bar

Rp 1/2 15 2 3 4,5 R295SA-1/2DRp 3/4 20 2 3 6 R295SA-3/4D

Rp 1 25 2 3 8 R295SA-1DRp 1 1/4 32 2 3 13 R295SA-11/4DRp 1 1/2 40 2 3 18 R295SA-11/2D

Rp 2 50 2 3 27 R295SA-2D

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07K-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07K-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07K-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07K-A25

Backflow preventer compact construction with threaded connectors, CA295

Approvals KIWA, BELGAQUA, NF (DN 15), tested to prEN 14367 (DN 15)

Media Water

Liquid category (EN1717) class 3

Body material brass, dezincification resistant

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Integral strainer• Compact construction• Easy access to all internal components• Low pressure loss and high flow rate performance• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones

Port connection Port diameter DN size Typeinch mm

external threads 1/2 15 CA295-1/2Aexternal threads 3/4 20 CA295-3/4Ainternal threads 1/2 15 CA295-1/2ZAinternal threads 3/4 20 CA295-3/4ZA

Page 461: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-6

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used mainly for OEM-applications, but can also be used for commercial and industrial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version, with threaded connections

Standard version, with tailpieces connection

Accessories

Backflow preventer, BA195 miniBA

Media Water

Liquid category (EN1717) class 4

Body material brass, dezincification resistant

Port connection external threads

Port diameter 3/8 inch

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimal protection of the drinking water supply network• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Compact construction• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Meets KTW recommendations for potable water

TypeBA195-3/8E

TypeBA195-3/8A

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Maintenance-set for BA195 type backflow preventers for use with Test kit TK295 resp. TKA295

WS195

Page 462: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-7

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version, with threaded connections

Standard version, without connection fitting

Backflow preventer compact construction with threaded connectors, BA295

Approvals • DIN/DVGW-approved for connection sizes 1/2" - 2"• KIWA-approved for connection sizes 1/2" - 2"• NF-approved for connection size 1/2"• Approved according to EN12729

Media Water

Liquid category (EN1717) class 4

Body material red bronze RG5

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimal protection of the drinking water supply network• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Compact construction• Easy access to all internal components• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Noise tested to class 2• Meets KTW recommendations for potable water

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

external threads 1/2 15 3 BA295-1/2Aexternal threads 3/4 20 3,5 BA295-3/4Aexternal threads 1 25 4 BA295-1Bexternal threads 1 1/4 32 8,7 BA295-11/4Bexternal threads 1 1/2 40 13,6 BA295-11/2Aexternal threads 2 50 21,2 BA295-2A

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

– – – 3 BA295-1/2E– – – 3,5 BA295-3/4E– – – 4 BA295-1E– – – 8,7 BA295-11/4E– – – 13,6 BA295-11/2E– – – 21,2 BA295-2E

Page 463: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-8

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Accessories

Spare parts

Noise protected pressure reducing valve with setting scale. For connection size 1/2" D06F-1/2B

Noise protected pressure reducing valve with setting scale. For connection size 1" D06F-3/4B

Noise protected pressure reducing valve with setting scale. For connection size 3/4" D06F-1B

Noise protected pressure reducing valve with setting scale. For connection size 11/4" D06F-11/4B

Noise protected pressure reducing valve with setting scale. For connection size 11/2" D06F-11/2B

Noise protected pressure reducing valve with setting scale. For connection size 2" D06F-2B

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Fine filter, reverse rinsable. For connection size 1/2" F76S-1/2AAM

Fine filter, reverse rinsable. For connection size 3/4" F76S-3/4AAM

Fine filter, reverse rinsable. For connection size 1" F76S-1AAM

Fine filter, reverse rinsable. For connection size 11/4" F76S-11/4AAM

Fine filter, reverse rinsable. For connection size 11/2" F76S-11/2AAM

Fine filter, reverse rinsable. For connection size 2" F76S-2AAM

Cartridge insert complete for old versions up to 12/11. For connection size 1/2", 3/4" and 1"

0903733

Cartridge insert complete for versions from 01/12 onwards. For connection size 1" and 11/4"

0904117

Cartridge insert complete for old versions up to 12/11. For connection size 11/4", 11/2" and 2"

0903745

Check valve cartridge with adapter ring and plug for versions from 01/01 onwards For connection size 3/4" and 1"

RV295-1/2

Check valve cartridge with adapter ring and plug for versions from 07/06 onwards For connection size 11/4", 11/2" and 2"

RV295-11/4

Check valve cartridge without adapter ring for versions from 03/09 onwards For connection size 1/2", 3/4" and 1"

RV295-1/2E

Check valve cartridge without adapter ring for versions from 03/12 onwards For connection size 1"

0904118

Check valve cartridge without adapter ring for versions from 03/12 onwards For connection size 11/4"

0904119

Page 464: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-9

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version

Accessories

Stainless Steel Backflow Preventer, BA295I

Approvals DIN/DVGW-certified

Media Water

Liquid category (EN1717) class 4

Body material stainless steel

Port connection external threads

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Stainless steel construction• Optimal protection of the drinking water supply network• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Easy access to all internal components• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Noise tested to class 2• Meets KTW recommendations for potable water

Port diameter DN size Typeinch mm

1 15 BA295I-1/2A1 20 BA295I-3/4A1 25 BA295I-1A2 32 BA295I-11/4A2 40 BA295I-11/2A2 50 BA295I-2A

Noise protected pressure reducing valve with setting scale. For connection size 1/2" D06F-1/2B

Noise protected pressure reducing valve with setting scale. For connection size 3/4" D06F-3/4B

Noise protected pressure reducing valve with setting scale. For connection size 1" D06F-1B

Noise protected pressure reducing valve with setting scale. For connection size 11/4" D06F-11/4B

Noise protected pressure reducing valve with setting scale. For connection size 11/2" D06F-11/2B

Noise protected pressure reducing valve with setting scale. For connection size 2" D06F-2B

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Page 465: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-10

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.

Standard version, with threaded connections

Accessories

Backflow preventer compact construction with threaded connectors, BA295C

Approvals DIN/DVGW

Media Water

Liquid category (EN1717) class 4

Body material red bronze RG5

Port connection external threads

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimal protection of the drinking water supply network• Integral inlet strainer and Integral inlet and outlet shutoff valves• Inlet non-return check valve and discharge valve are combined

in one cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation

Port diameter DN size Typeinch mm

1/2 15 BA295C-1/2A3/4 20 BA295C-3/4A

1 25 BA295C-1B1 1/4 32 BA295C-11/4B1 1/2 40 BA295C-11/2A

2 50 BA295C-2A

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Noise protected pressure reducing valve with setting scale. For connection size 1/2" D06F-1/2B

Noise protected pressure reducing valve with setting scale. For connection size 3/4" D06F-3/4B

Noise protected pressure reducing valve with setting scale. For connection size 1" D06F-1B

Noise protected pressure reducing valve with setting scale. For connection size 11/4" D06F-11/4B

Noise protected pressure reducing valve with setting scale. For connection size 11/2" D06F-11/2B

Noise protected pressure reducing valve with setting scale. For connection size 2" D06F-2B

Fine filter, reverse rinsable. For connection size 1/2" F76S-1/2AAM

Fine filter, reverse rinsable. For connection size 3/4" F76S-3/4AAM

Fine filter, reverse rinsable. For connection size 1" F76S-1AAM

Fine filter, reverse rinsable. For connection size 11/4" F76S-11/4AAM

Fine filter, reverse rinsable. For connection size 11/2" F76S-11/2AAM

Page 466: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-11

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

Spare parts

Spare parts for old versions

Cartridge insert complete. For connection size 1/2" - 1" 0903733

Cartridge insert complete. For connection size 11/4" - 2" 0903745

Check valve cartridge without adapter ring. For connection size 1/2" - 1" RV295-1/2E

Check valve cartridge without adapter ring. For connection size 11/4" - 2" RV295-11/4E

Shutoff valve. For connection size 1/2" 2192900

Shutoff valve. For connection size 3/4" 2193100

Shutoff valve. For connection size 1" 2193200

Shutoff valve. For connection size 11/4" 2193300

Shutoff valve. For connection size 11/2" 2193400

Shutoff valve. For connection size 2" 2193500

Check valve complete for old versions up to 05/06, with check valve cone and spring made of red bronze. For connection size 1/2" - 1"

RV295-1/2

Check valve complete for old versions up to 05/06, with check valve cone and spring made of red bronze. For connection size 11/4" - 2"

RV295-11/4

Check valve complete for old versions up to 02/09, with adapter ring. For connection size 1/2"

RV295-1/2

Check valve complete for old versions up to 10/08, with adapter ring. For connection size 3/4"

RV295-1/2

Check valve complete for old versions up to 12/08, with adapter ring. For connection size 1"

RV295-1/2

Check valve complete for old versions up to 08/08, with adapter ring. For connection size 11/4"

RV295-11/4

Check valve complete for old versions up to 05/09, with adapter ring. For connection size 11/2"-2"

RV295-11/4

Page 467: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-12

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. They are used to protect the temporary water tapping of standpipes on events or construction sites. Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version, with threaded connections

Housing chromium plated, with threaded connections

Accessories

Spare parts

Retrofit Backflow Preventer for standpipes, BA295STN

Approvals DVGW approved

Media Water

Liquid category (EN1717) class 4

Body material brass, dezincification resistant

Port connection external threads

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position vertical

Additional description • Pivoted top connection• Optimal protection of the drinking water supply system• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Compact construct• Easy access to all internal components• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Meets KTW recommendations for potable water• Easy and quick installation• Each tapping can be protected separately• Seal-jacket to protect against manipulations• Easy maintenance due to upstream shut-off

Port diameter DN size Typeinch mm

1 20 BA295STN-3/4A

Port diameter DN size Typeinch mm

3/4 15 BA295STN-3/4AC12

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Maintenance-set for BA 295STN type backflow preventers WS295STN

Cartridge insert 0903733

Check valve insert 2110200

Filter S295STN

Set of blanking plugs-MS for Option A 0903889

Set of blanking plugs-MS for Option AC12 0903886

Page 468: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-13

Backflow Preventers

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.They are used to protect the water tapping of houshould taps, outside garden taps or filling taps. Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version with C-coupling on outlet

Accessories

Spare parts

Chromed Backflow Preventer for standpipes, BA295STN-WH

Approvals DVGW approved

Media Water

Liquid category (EN1717) class 4

Body material brass, dezincification resistant

Body finishing chrome plated

Port connection external threads

Port diameter 3/4 inch

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Pivoted top connection• Optimal protection of the drinking water supply system• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Compact construct• Easy access to all internal components• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Meets KTW recommendations for potable water• Easy and quick installation/retrofit• Each tapping can be protected separately• Easy maintenance due to upstream shut-off

TypeBA295STN-3/4WH

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Maintenance-set for BA295STN type backflow preventers for use with Test kit TK295 resp. TKA295

WS295STN

Cartridge insert 0903733

Check valve insert 2110200

Filter S295STN

Set of blanking plugs 0903886

Page 469: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-14

Backflow Preventers

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.They are used to protect the temporary water tapping of stand-pipes on events or construction sites.Fluids up to and including liquid category 4 to EN 1717 are protected.

Standard version with C-coupling on outlet

Accessories

Spare parts

Backflow Preventer for standpipes, BA295STN-A

Approvals DVGW-approval requested

Media Water

Liquid category (EN1717) class 4

Body material brass

Port connection external threads

Port diameter 1 1/2 inch

DN size 40 mm

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimal protection of the drinking water supply system• Brass housing, lead-free• Integral inlet strainer• Inlet check valve and discharge valve are combined in one

cartridge• Minimal maintenance required, because the valve cartridge is

completely replaceable• Optimized design prevents water stagnation• Compact construct• Easy access to all internal components• Low pressure loss and high flow rate• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Meets KTW recommendations for potable water• Each tapping can be protected separately

TypeBA295STN-11/2A

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Blind plug C-coupling with integrated test socket for checking standpipe-BA BS295STN-11/2A

Cartridge insertcomplete 0903745

Shutoff facility complete AE295STN-11/2A

Sieve S295STN-11/2

Sealing set DS295STN-11/2

Page 470: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-15

Backflow Preventers with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow Preventers with flanges

Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems" and correspond to DIN1988 part 4 type 1 construction. Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors can be used to provide protection up to and including liquid category 3 (slightly toxic substances) and therefore offer better protection than check valves.

With flanges, 0,5 bar opening pressure

With flanges, 1,0 bar opening pressure (standard pattern)

With flanges, 1,5 bar opening pressure (DN 65 - DN 100 only)

Mechanical disconnector with flanges direct actuated, GA type according to EN 1717/ type 1 according to DIN1988 part 4, R295P-F

Media Water

Liquid category (EN1717) class 3

Body material cast iron GG25

Body finishing powder coating

Port connection flanges

Max. media temperature 40 oC

Pressure rating PN10

Mounting position horizontal

Additional description • Optimum protection of the drinking water supply system • Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off position visually indicated on the spring bonnet • Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Low pressure loss and high flow rate

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 0,5 1,5 50 R295P-65FA80 0,5 1,5 62 R295P-80FA

100 0,5 1,5 125 R295P-100FA125 0,5 1,5 208 R295P-125FA150 0,5 1,5 274 R295P-150FA200 0,5 1,5 362 R295P-200FA

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 1 2 50 R295P-65FB80 1 2 62 R295P-80FB

100 1 2 125 R295P-100FB125 1 2 208 R295P-125FB150 1 2 274 R295P-150FB200 1 2 362 R295P-200FB

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 1,5 2,5 50 R295P-65FC80 1,5 2,5 62 R295P-80FC

100 1,5 2,5 125 R295P-100FC

Page 471: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-16

Backflow Preventers with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems" and correspond to DIN1988 part 4 type 2 construction. Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors of this type can be used to provide protection up to and including liquid category 4 (toxic, very toxic, carcinogenic and radioactive substances).

With flanges, differential pressure 0,5 bar, self adjusting

Mechanical disconnector hydraulic actuated, GB type according to EN 1717/ type 2 according to DIN1988 part 4, R295HP-F

Media Cold water

Liquid category (EN1717) class 4

Body material cast iron GG25

Body finishing powder coating

Port connection flanges

Max. media temperature 40 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • Optimum protection of the drinking water supply system • Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off condition visually indicated on the spring bonnet • Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Low pressure loss

DN size Flow capacity Kvs Typemm

65 24 R295HP-65FA80 35 R295HP-80FA

100 50 R295HP-100FA125 100 R295HP-125FA150 150 R295HP-150FA200 248 R295HP-200FA

Page 472: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-17

Backflow Preventers with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Mechanical disconnectors of this type are suitable for the protection of drinking water systems as required by EN 1717 "The technical regulation of drinking water systems" and correspond to DIN1988 part 4 type 2 construction. Their purpose is to protect systems against back pressure, back flow and back syphonage of non-potable water into the public water supply network. Mechanical disconnectors of this type can be used to provide protection up to and including liquid category 4 (toxic, very toxic, carcinogenic and radioactive substances). The changeover from shutoff to flow positions can be by means of an hydraulic or electrical/electronic actuator.

With flanges, opening pressure 0,5 bar

With flanges, opening pressure 1,0 bar (Standard pattern)

With flanges, opening pressure 1,5 bar

Mechanical disconnector electrically actuated, GB type according to EN 1717/ type 2 according to DIN1988 part 4, R295SP-F

Media Cold water

Power supply 230V 50Hz

Liquid category (EN1717) class 4

Body material cast iron GG25

Body finishing powder coating

Port connection flanges

Max. media temperature 40 oC

Pressure rating PN10

Mounting position horizontal

Additional description • Optimum protection of the drinking water supply system• Enhanced protection against back pressure, back flow and

back syphonage into the water supply network• Shut-off position visually indicated on the spring bonnet • Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Low pressure loss

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 0,5 1,5 50 R295SP-65FA80 0,5 1,5 62 R295SP-80FA

100 0,5 1,5 125 R295SP-100FA125 0,5 1,5 208 R295SP-125FA150 0,5 1,5 274 R295SP-150FA200 0,5 1,5 362 R295SP-200FA

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 1 2 50 R295SP-65FB80 1 2 62 R295SP-80FB

100 1 2 125 R295SP-100FB125 1 2 208 R295SP-125FB150 1 2 274 R295SP-150FB200 1 2 362 R295SP-200FB

DN size Set pressure Minimum inlet pressure Flow capacity Kvs Typemm bar bar

65 1,5 2,5 50 R295SP-65FC80 1,5 2,5 62 R295SP-80FC

100 1,5 2,5 125 R295SP-100FC

Page 473: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-18

Backflow Preventers with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.

Standard version with PN 10 flanges

Accessories

Reduced-pressure-zone backflow preventer with flange connections, BA298-F

Approvals DVGW, SVGW, WRC

Media Water

Liquid category (EN1717) class 4

Body material brass, dezincification resistant

Port connection flanges

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • European approvals in all connection sizes• Optimum protection of the drinking water supply system• Easy access to all inner components• Stainless steel housing gives increased corrosion protection • Easy Maintenance due to optimized construction

DN size Flow capacity Kvs Typemm

65 45 BA298-65FA80 54 BA298-80FA

100 85 BA298-100FA150 191 BA298-150FA

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Check valve replacement tool for connection sizes DN65 - 100 WBA298-100

Check valve replacement tool for connection size DN150 WBA298-150

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN65

FY69P-65A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN80

FY69P-80A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN100

FY69P-100A

Strainer with double mesh, grey cast iron housing, powder coated inside and outside. For connection size DN150

FY69P-150A

Page 474: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-19

Backflow Preventers with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage. Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification. The stainless steel housing provides increased corrosion protection.

Standard version with PN 10 flanges

Accessories

Spare parts

Reduced-pressure-zone backflow preventer with flange connections - Industrial model, BA298I-F

Approvals DVGW, SVGW, WRC

Media Water

Liquid category (EN1717) class 4

Body material stainless steel

Port connection flanges

Max. media temperature 65 oC

Pressure rating PN10

Minimum inlet pressure 1,5 bar

Mounting position horizontal

Additional description • European approvals in all connection sizes• Optimum protection of the drinking water supply system• Easy access to all inner components• Easy Maintenance due to optimized construction

DN size Flow capacity Kvs Typemm

65 45 BA298I-65FA80 54 BA298I-80FA

100 85 BA298I-100FA150 191 BA298I-150FA

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Check valve replacement tool for connection sizes DN 65 - 100 WBA298-100

Check valve replacement tool for connection size DN 150 WBA298-150

Discharge valve 0901856

Inlet ckeck valve for connection sizes DN 65 - 100 0901652

Inlet ckeck valve for connection size DN 150 0901656

Outlet ckeck valve for connection sizes DN 65 - 100 0901653

Outlet ckeck valve for connection size DN 150 0901657

Ball valve for connection sizes DN 65 - 150 0901662

Sealing set for connection sizes DN 65 - 100 0904031

Sealing set for connection size DN 150 0904032

Clamp complete connection sizes DN 65 - 100 0904033

Clamp complete connection size DN 150 0904034

Page 475: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-20

Backflow Preventers with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Backflow preventers of this type are suitable for the protection of drinking water systems against back pressure, back flow and back syphonage.Fluids up to and including liquid category 4 to EN 1717 are protected. They can be used for residential buildings, industrial and commercial purposes within the scope of their specification.The powder coated ductile iron housing provides increased corrosion protection.

Standard version with PN 10 flanges

Accessories

Backflow preventer with flanged connections, BA300

Approvals DVGW and NF certification for all connection sizes, SVGW and WRC certification in process

Media Water

Liquid category (EN1717) class 4

Port connection flanges

Max. media temperature 65 oC

Pressure rating PN10

Mounting position horizontal

Minimum inlet pressure 1,5 bar

Additional description • Optimal protection of the drinking water supply system• Easy access to all internal components• Powder coated ductile iron housing gives increased corrosion

protection• Easy Maintenance due to optimized construction• Triple security - two check valves and a discharge valve

separate the backflow preventer into three pressure zones• Few individual parts• Light weight• Standardised discharge connection• Meets KTW recommendations for potable water

DN size Flow capacity Kvs Typemm

65 35,8 BA300-65A80 54,3 BA300-80A

100 84,3 BA300-100A150 190,9 BA300-150A200 339,3 BA300-200A

Test kit. Electronic pressure measuring device with digital indicator, runs by a battery. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TK295

Test kit. Analogue pressure measuring device with differential pressure display. With case and accessories, ideal for inspection and maintenance of backflow preventer type BA.

TKA295

Strainer with double sieve, grey cast iron housing, powder coated inside and outside. Mesh size approximately 0.5 mm

FY69P-65A

Strainer with double sieve, grey cast iron housing, powder coated inside and outside. Mesh size approximately 0.5 mm

FY69P-80A

Strainer with double sieve, grey cast iron housing, powder coated inside and outside. Mesh size approximately 0.5 mm

FY69P-100A

Strainer with double sieve, grey cast iron housing, powder coated inside and outside. Mesh size approximately 0.5 mm

FY69P-150A

Strainer with double sieve, grey cast iron housing, powder coated inside and outside. Mesh size approximately 0.5 mm

FY69P-200A

Reverse-rinsing filter. Red bronze housing and filter bowl. F76S-65FA

Reverse-rinsing filter. Red bronze housing and filter bowl. F76S-80FA

Reverse-rinsing filter. Red bronze housing and filter bowl. F76S-100FA

Page 476: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-21

Backflow Preventers with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Spare parts

Inlet check valve for connection size DN65 0904052

Inlet check valve for connection size DN80 0904053

Inlet check valve for connection size DN100 0904054

Inlet check valve for connection size DN150 0904055

Inlet check valve for connection size DN200 0904056

Outlet check valve for connection size DN65 0904057

Outlet check valve for connection size DN80 0904058

Outlet check valve for connection size DN100 0904059

Outletcheck valve for connection size DN150 0904060

Outlet check valve for connection size DN200 0904061

Discharge valve for connection sizes DN65 - DN200 0904062

Pressure control line for connection size DN65 0904063

Pressure control line for connection size DN80 0904064

Pressure control line for connection size DN100 0904065

Pressure control line for connection size DN150 0904066

Pressure control line for connection size DN200 0904067

Sealing set for connection size DN65 0904068

Sealing set for connection size DN80 0904069

Sealing set for connection size DN100 0904070

Sealing set for connection size DN150 0904071

Sealing set for connection size DN200 0904072

Page 477: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-22

Non-return Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Non-return Valves with flanges

The check valve is a safety device in accordance with EN 1717 to protect systems against back pressure, back flow and back syphonage of non-potable water into service pipe, plants and equipments.Check valves of this type are priority suitable for domestic drinking water supply. The check valve can be used for commercial and industrial applications in consideration of its specifications. Check valves must be fitted, if service pipe, plant and equipment must be protected against back pressure, back flow and back syphonage of non-potable water.

With soldering connection

With threaded connection

With compression connection 15 and 22

Check valve made of brass, RV181

Approvals KIWA

Media Water

Liquid category (EN1717) class 2

Max. media temperature 65/90 oC

Body material brass, dezincification resistant

Pressure rating PN16

Mounting position horizontal

Additional description Operating temperature accord. DIN EN 13969: water up to 65 oC (short term up to 90 oC)

• Optimal protection of the drinking water supply system• Compact construction• Corrosion resistant by use of dezincification resistant brass• Universal application• Low pressure loss• Quiet operation• Create no shock pressure loadings• No spare parts

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

soldering 1/2 15 6 RV181-1/2Asoldering 3/4 20 10 RV181-3/4Asoldering 1 25 15 RV181-1Asoldering 1 1/4 32 28 RV181-11/4Asoldering 1 1/2 40 41 RV181-11/2Asoldering 2 50 70 RV181-2A

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

external threads 1/2 15 6 RV181-1/2Bexternal threads 3/4 20 10 RV181-3/4Bexternal threads 1 25 15 RV181-1Bexternal threads 1 1/4 32 28 RV181-11/4Bexternal threads 1 1/2 40 41 RV181-11/2Bexternal threads 2 50 70 RV181-2B

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

coupling compressing fitting 1/2 15 6 RV181-1/2Kcoupling compressing fitting 3/4 20 10 RV181-3/4K

Page 478: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-23

Non-return Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Check valves of this type are particularly suitable for integral use with pipeline appliances such as water meters.Check valves are safety devices for independent prevention of water backflow, for example from drinking water appliances back into the central water supply system. They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The classicfications of appliances to meet these requirements are specified in EN 1717.

Long version

Short version

Spare parts

Controllable anti-pollution check valve EA type, add-on for pressure reducing valves and filters, RV260

Approvals VA-approved

Media Water

Body material brass

Port diameter 3/4 inch

DN size 15 mm

Pressure rating PN16

Flow capacity Kvs 2,9

Mounting position horizontal or vertical

Additional description Operating temperature 5...40 C• Universal application• Easy installation • Quiet operation• Creates no shock pressure loadings• Meets KTW recommendations for potable water• Suitable for installation in any position• Low pressure loss

TypeRV260-3/4AA

TypeRV260-3/4AS

Check valve cartridge 3/4" 2110200

Page 479: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-24

Non-return Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Check valves of this type are particularly suitable for integral use with pressure reducing valves, filters and filter combinations of all types.Check valves are safety devices for independent prevention of water backflow, for example from drinking water appliances back into the central water supply system. They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The classicfications of appliances to meet these requirements are specified in EN 1717.

Standard version with male threaded union 1/2" - 2" and female threaded union nut 1" - 2 1/2". DN is based on connection size of male threaded union

Spare parts

Controllable anti-pollution check valve EA type, add-on for pressure reducing valves and filters, RV277

Approvals DIN/DVGW

Media Water

Liquid category (EN1717) class 2

Max. media temperature 65/90 oC

Body material brass

Pressure rating PN25

Mounting position horizontal or vertical

Additional description Operating temperature accord. DIN EN 13969: max. 65 C (short term operation up to 90 C)

• Universal application• Easy installation • Quiet operation• Creates no shock pressure loadings• Meets KTW recommendations for potable water• Suitable for installation in any position• Low pressure loss

Port diameter DN size Flow capacity Kvs Typeinch mm

1/2 15 6 RV277-1/2A3/4 20 10 RV277-3/4A

1 25 15 RV277-1A1 1/4 32 28 RV277-11/4A1 1/2 40 41 RV277-11/2A

2 50 70 RV277-2A

Union seal washer for 3/4" (10 pcs.) 0901444

Union seal washer for 1" (10 pcs.) 0901445

Union seal washer for 1 1/4" (10 pcs.) 0901446

Union seal washer for 1 1/2" (10 pcs.) 0901447

Union seal washer for 2" (10 pcs.) 0901448

Blanking plug with O-ring R1/4"(5 pcs.) S06K-1/4

Check valve cartridge 1/2" 2166200

Check valve cartridge 3/4" 2110200

Check valve cartridge 1" 2164400

Check valve cartridge 1 1/4" 2164500

Check valve cartridge 1 1/2" 2164600

Check valve cartridge 2" 2164700

Page 480: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-25

Non-return Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Check valves of this type are for use as an independent means of preventing reverse water flow.They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The classicfications of appliances to meet these requirements are specified in EN 1717.

Standard version

Spare parts

Controllable anti-pollution check valve EA type with internal thread, RV280

Media Water, compressed air, petroleum, medium and light fuel oils, kerosene, gasoline with less than 15 % aromatic content. Not suitable for gaseous mediums below 0,5 bar, steam, heavy oils and benzole.

Liquid category (EN1717) class 2

Max. media temperature 60/65/90 oC

Body material brass

Port connection internal threads

Pressure rating PN16

Mounting position horizontal or vertical

Additional description Operating temperature accord. DIN EN 13969: water up to 65 oC (short term up to 90 oC). With compressed air and other mediums up to 60 oC

• Universal application • Suitable for installation in any orientation• Creates no shock pressure loadings• Meets KTW recommendations for potable water• Low pressure loss

Port diameter DN size Flow capacity Kvs Typeinch mm

Rp 1/2 15 4,5 RV280-1/2ARp 3/4 20 9,1 RV280-3/4A

Rp 1 25 17 RV280-1ARp 1 1/4 32 28 RV280-11/4ARp 1 1/2 40 38 RV280-11/2A

Rp 2 50 60 RV280-2A

Disc guide 1/2" 5534900

Disc guide 3/4" 5535100

Disc guide 1" 5531500

Disc guide 1 1/4" 5535300

Disc guide 1 1/2" 5535500

Disc guide 2" 5535700

Spring 1/2" 2061400

Spring 3/4" 2061500

Spring 1" 2061600

Spring 1 1/4" 2061700

Spring 1 1/2" 2062000

Spring 2" 2062400

Valve disc complete 1/2" 0900356

Valve disc complete 3/4" 0900357

Valve disc complete 1" 0900358

Valve disc complete 1 1/4" 0900359

Valve disc complete 1 1/2" 0900360

Valve disc complete 2" 0900361

Hexagon-plug with copper sealing-ring R1/4" (5 pcs.) S06M-1/4

Page 481: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-26

Non-return Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Check valves of this type are for use as an independent means of preventing reverse water flow and for installing directly after a water meter on central water supply systems.They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The classicfications of appliances to meet these requirements are specified in EN 1717.

Hexagonal connection with internal thread

With soldered union connectors

Without connections

Controllable anti-pollution check valve EA type with union connectors, RV281

Approvals • DIN/DVGW-certified• Fully approved for noise level protection to class 1

Media Water, compressed air, petroleum, medium and light fuel oils, kerosene, gasoline with less than 15 percent aromatic content. Not suitable for gaseous mediums below 0,5 bar, steam, heavy fuel oils or benzole.

Liquid category (EN1717) class 2

Max. media temperature 60/65/90 oC

Body material brass

Pressure rating PN16

Mounting position horizontal or vertical

Additional description Operating temperature accord. DIN EN 13959: water up to 65 oC (short term up to 90 oC). Compressed air and other mediums up to 60 oC

• Universal application• Suitable for installation in any position• Creates no shock pressure loadings• Union connectors simplify service• Low pressure loss• Meets KTW recommendations for potable water

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

internal threads 1/2 15 4,5 RV281-1/2Ainternal threads 3/4 20 9,1 RV281-3/4Ainternal threads 1 25 17 RV281-1Ainternal threads 1 1/4 32 28 RV281-11/4Ainternal threads 1 1/2 40 38 RV281-11/2Ainternal threads 2 50 60 RV281-2A

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

soldering 1/2 15 4,5 RV281-1/2Bsoldering 3/4 20 9,1 RV281-3/4Bsoldering 1 25 17 RV281-1Bsoldering 1 1/4 32 28 RV281-11/4Bsoldering 1 1/2 40 38 RV281-11/2Bsoldering 2 50 60 RV281-2B

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

external threads 3/4 15 4,5 RV281-1/2Eexternal threads 1 20 9,1 RV281-3/4Eexternal threads 1 1/4 25 17 RV281-1Eexternal threads 1 1/2 32 28 RV281-11/4Eexternal threads 2 40 38 RV281-11/2Eexternal threads 2 1/2 50 60 RV281-2E

Page 482: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-27

Non-return Valves with flanges

16

17

18

19

20

21

22

24

23

25

26

27

28

Check valves of this type are for use as an independent means of preventing reverse water flow. They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The classicfications of appliances to meet these requirements are specified in EN 1717.

With internal threads

With compression connections

Controllable anti-pollution check valve EA type, RV284

Approvals DIN/DVGW

Media Water

Liquid category (EN1717) class 2

Max. media temperature 70 oC

Body material brass

Pressure rating PN25

Mounting position horizontal

Additional description • Universal application• Easy installation• Low pressure loss• Quiet operation• Create no shock pressure loadings

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

internal threads 1/2 15 1,6 RV284-1/2Ainternal threads 3/4 20 3,4 RV284-3/4Ainternal threads 1 25 6,4 RV284-1A

Port connection Port diameter DN size Flow capacity Kvs Typeinch mm

coupling compressing fitting – 15 1,6 RV284-15Bcoupling compressing fitting – 20 3,4 RV284-20Bcoupling compressing fitting – 25 6,4 RV284-25B

Page 483: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

20-28

Non-return Valves with flanges

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Check valves are preferably for use as an independent means of preventing reverse water flow and are for installing directly after a water meter, but also for application in transfer pipes on district water supply systems. They can also be used for industrial, commercial and similar systems where back pressure, back flow and back syphonage must be prevented. The types of safety devices required for these purposes are specified in EN 1717.

With drilled flanges, PN 16, EPDM lip seal ring

With drilled flanges, PN 10, EPDM lip seal ring

Controllabel anti-pollution check valve with flanges, RV283P

Approvals DIN/DVGW

Media Water, compressed air and nitrogen in consideration of valid standards (e.g. DIN EN 12502)

Liquid category (EN1717) class 2

Max. media temperature 70 oC

Body material cast iron GG25

Body finishing powder coating

Port connection flanges

Mounting position horizontal

Additional description • Universal application• High temperature resistance• Creates no shock pressure loadings• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Disc, spring and lip seal ring are exchangeable

DN size Pressure rating Flow capacity Kvs Typemm

40 PN16 39 RV283P-40A50 PN16 62 RV283P-50A65 PN16 110 RV283P-65A80 PN16 170 RV283P-80A

100 PN16 240 RV283P-100A125 PN16 420 RV283P-125A150 PN16 760 RV283P-150A200 PN16 1400 RV283P-200A250 PN16 2100 RV283P-250A300 PN16 3000 RV283P-300A

DN size Pressure rating Flow capacity Kvs Typemm

40 PN10 39 RV283P-40B50 PN10 62 RV283P-50B65 PN10 110 RV283P-65B80 PN10 170 RV283P-80B

100 PN10 240 RV283P-100B125 PN10 420 RV283P-125B150 PN10 760 RV283P-150B200 PN10 1400 RV283P-200B250 PN10 2100 RV283P-250B300 PN10 3000 RV283P-300B

Page 484: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Safety Valves/Groups, Thermostatic Mixing Valves, residential/industrial Page

Safety Valves 21-2Safety Groups 21-6Thermostatic Mixing Valves 21-16

Page 485: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-2

Safety Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Safety Valves

Type SM152 diaphragm-type safety valves are used to protect pressurised water heaters according to the requirements of DIN 4753, Part 1 and DIN 1988. In accordance with statutory requirements, the diaphragm safety valve is preset to the required fixed set pressure by the manufacturer and is sealed with an embossed security cap marked with the test badge and pressure rating to prevent unauthorised tampering with the setting. Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap. The preset pressure is embossed on the security cap.

Not chrome plated, set pressure 6,0 bar

Not chrome plated, set pressure 8,0 bar

Not chrome plated, set pressure 10,0 bar

Diaphragm safety valve for closed water heaters, SM152

Approvals TUEV approved, certified to Pressure Equipment Directive 97/23/EG, Reference No. CE 0035

Media Water

Body material brass

Spring bonnet material synthetic material

Port connection internal threads

Max. media temperature 95 oC

Additional description The valve size is defined by the size of the inlet connection. For closed water heaters in compliance with DIN 4753, Part 1 and EN 1717. Tested to TRD 721 for pressure range 1.0 bar to 10.0 bar.

• Tested to TRD 721• Easy venting• Replacement insert makes servicing simple• Standardised discharge connection

Port diameter DN size Set pressure Typeinch mm bar

1/2 15 6 SM152-1/2AA3/4 20 6 SM152-3/4AA

1 25 6 SM152-1AA1 1/4 32 6 SM152-11/4AA

Port diameter DN size Set pressure Typeinch mm bar

1/2 15 8 SM152-1/2AB3/4 20 8 SM152-3/4AB

1 25 8 SM152-1AB1 1/4 32 8 SM152-11/4AB

Port diameter DN size Set pressure Typeinch mm bar

1/2 15 10 SM152-1/2AC3/4 20 10 SM152-3/4AC

1 25 10 SM152-1AC1 1/4 32 10 SM152-11/4AC

Page 486: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-3

Safety Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Chrome plated, set pressure 6,0 bar

Chrome plated, set pressure 10,0 bar

Spare Parts

Port diameter DN size Set pressure Typeinch mm bar

1/2 15 6 SM152-1/2BA

Port diameter DN size Set pressure Typeinch mm bar

1/2 15 10 SM152-1/2BC

Safety valve insert, set pressure 6 bar, for sizes R 1/2" A152-1/2AA

Safety valve insert, set pressure 6 bar, for sizes R 3/4" A152-3/4AA

Safety valve insert, set pressure 6 bar, for size R 1" A152-1AA

Safety valve insert, set pressure 8 bar, for sizes R 1/2" A152-1/2AB

Safety valve insert, set pressure 8 bar, for sizes R 3/4" A152-3/4AB

Safety valve insert, set pressure 8 bar, for size R 1" A152-1AB

Safety valve insert, set pressure 10 bar, for sizes R 1/2" A152-1/2AC

Safety valve insert, set pressure 10 bar, for sizes R 3/4" A152-3/4AC

Safety valve insert, set pressure 10 bar, for size R 1" A152-1AC

Safety valve insert with chrome plated body, set pressure 8 bar, for sizes R 1/2" A152-1/2BB

Safety valve insert with chrome plated body, set pressure 8 bar, for sizes R 3/4" A152-3/4BB

Safety valve insert with chrome plated body, set pressure 10 bar, for sizes R 1/2" A152-1/2BC

Safety valve insert with chrome plated body, set pressure 10 bar, for sizes R 3/4" A152-3/4BC

Safety valve insert, set pressure 6 bar, for sizes R 1 1/4" A160-11/4AA

Safety valve insert, set pressure 8 bar, for sizes R 1 1/4" A160-11/4AB

Safety valve insert, set pressure 10 bar, for sizes R 1 1/4" A160-11/4AC

Page 487: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-4

Safety Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The S245B safety valves are direct loaded high performance safety valves with lifting device. They protect pressurized compressed air vessels (cylinders, tanks) against excessive pressure. S245B safety valves are used for compressors and other industrial purposes.

Soft seat version, set pressure within the range of 1,0 - 12,0 bar

Soft seat version, set pressure within the range of <1,0 or >12,0 bar

High performance safety valve for compressed air, S245B

Approvals CE, VdTUEV, ASME

Body material brass

Port connection external threads

Max. media temperature 180 oC

Pressure setpoint range 1 ... 12 bar

Additional description • Sturdy metal construction• Shakeproof lifting mechanism admitting no additional load• Type S245B approved by VdTUEV for pressure range from 0,5 -

30,0 bar and approved by ASME (American Society of Mechanical Engineers) for pressure range 2,8 - 30,0 bar (41 - 435 PSI)

• Type S245B certified to Pressure Equipment Directive 97/23/EC, Reference No. CE 0035

• Set pressure settings possible between 0,5 and 30 bar in steps of 0,1 bar

Spring bonnet material Port diameter (inch) Typebrass G 1/2 S245B-12ZA*...brass G 3/4 S245B-34ZA*...brass G 1 S245B-1ZA*...

cast iron GG25 G 1 1/4 S245B-114ZA*...cast iron GG25 G 1 1/2 S245B-112ZA*...cast iron GG25 G 2 S245B-2ZA*...

Spring bonnet material Port diameter (inch) Typebrass G 1/2 S245B-12ZB*...brass G 3/4 S245B-34ZB*...brass G 1 S245B-1ZB*...

cast iron GG25 G 1 1/4 S245B-114ZB*...cast iron GG25 G 1 1/2 S245B-112ZB*...cast iron GG25 G 2 S245B-2ZB*...

Page 488: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-5

Safety Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

The S245S safety valves are direct loaded high performance safety valves with lifting device. The venting bonnet discharges the medium downwards. The S245S safety valves protect fixed vessels containing granular or powdered materials or silo tank vehicles containing fluids, granular or powdered materials which are unloaded using compressed air.

Direct-acting safety valves

High performance safety valve for compressed air, S245S

Approvals VdTUEV, Certified to Pressure Equipment Directive 97/23/EG, Reference No. CE 0035

Body material brass

Spring bonnet material cast iron GG25

Port connection external threads

Max. media temperature 180 oC

Pressure setpoint range 0,9 ... 4,3 bar

Additional description • Sturdy metal construction• Shakeproof lifting mechanism admitting no additional load• Rubber bellows for protection of moving parts• Venting bonnet for downwards discharge of fluid• Approved to AD information sheet A 2 and to VdTUEV information

sheet safety valve 100 for set relief pressure between 0.9 and 4.3 bar

• Set pressure adjustment at factory• Standard pressure settings between 0.9 and 4.3 bar in steps of

0.1 bar

Port diameter Typeinch

G 1 1/4 S245S-114Z*...G 1 1/2 S245S-112Z*...

Page 489: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-6

Safety Groups

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Safety Groups

Safety groups of this type are used to protect pressurised water heaters according to the requirements of DIN 4753, Part 1, DIN 1988 and DIN EN1488.They are compact appliances which incorporate all the necessary safety devices such as check valve, shutoff valve, test point and diaphragm type safety valve in one unit. The safety valve protects the downstream cylinder, pressure vessel etc. by automatically opening when excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of water from the hot water unit.

With threaded male connections, set pressure 6,0 bar

With threaded male connections, set pressure 8,0 bar

With threaded male connections, set pressure 10,0 bar

Without fittings, set pressure 6.0 bar

Safety group with interchangeable safety valve insert, SG150

Approvals DVGW-approval requested

Media Water

Body material brass, dezincification resistant

Max. media temperature 40 oC

Additional description For closed hot water storage units up to 200 litres according to DIN 4753 Part 1 and DIN 1988. Tested to TRD 721 for 1.0 to 10.0 bar pressure range

• Fully approved for noise level protection to class 1• Replacement insert tested to TRD 721• Easy venting• Meets KTW recommendations for potable water

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 6 SG150-1/2AAexternal threads 3/4 20 6 SG150-3/4AA

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 8 SG150-1/2ABexternal threads 3/4 20 8 SG150-3/4AB

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 10 SG150-1/2ACexternal threads 3/4 20 10 SG150-3/4AC

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 15 6 SG150-1/2EA– – 20 6 SG150-3/4EA

Page 490: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-7

Safety Groups

16

17

18

19

20

21

22

24

23

25

26

27

28

Without fittings, set pressure 8.0 bar

Without fittings, set pressure 10.0 bar

Accessories

Spare Parts

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 15 8 SG150-1/2EB– – 20 8 SG150-3/4EB

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 15 10 SG150-1/2EC– – 20 10 SG150-3/4EC

Pressure gauge with housing diameter 50 mm, connecting pin above G 1/4, range 0 - 16 bar

M08M16

Pressure reducing valve for completion of the safety group SG150 with connection size 1/2"

D150-1/2

Pressure reducing valve for completion of the safety group SG150 with connection size 3/4"

D160S-3/4

Connection set with 1/2" threaded male connections VST06-1/2A

Connection set with 3/4" threaded male connections VST06-3/4A

Connection set with 1/2" solder connections VST06-1/2B

Connection set with 3/4" solder connections VST06-3/4B

Discharge tundish TA160S

Plug with O-ring R1/4" (packs of 5) S06K-1/4

Safety valve insert, set pressure 6 bar A152-1/2AA

Safety valve insert, set pressure 6 bar A152-3/4AA

Safety valve insert, set pressure 8 bar A152-1/2AB

Safety valve insert, set pressure 8 bar A152-3/4AB

Safety valve insert, set pressure 10 bar A152-1/2AC

Safety valve insert, set pressure 10 bar A152-3/4AC

Check valve insert for safety valves 1/2" 2166200

Check valve insert for safety valves 3/4" 2110200

Page 491: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-8

Safety Groups

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Safety groups of this type are used to protect pressurised water heaters according to the requirements of DIN 4753, Part 1, DIN 1988 and DIN EN1488.They are compact appliances which incorporate all the necessary safety devices such as check valve, shutoff valve, test point, diaphragm type safety valve and pressure reducing valve in one unit. The safety valve protects the downstream cylinder, pressure vessel etc. by automatically opening when excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of water from the hot water unit. In addition, a balanced seat pressure reducing valve is fitted on the inlet to control the supply pressure to that required for the system.

With threaded male connections, set pressure 6,0 bar

With threaded male connections, set pressure 8,0 bar

With threaded male connections, set pressure 10,0 bar

Without fittings, set pressure 6.0 bar

Safety group with interchangeable safety valve insert and pressure reducing valve, SG150D

Approvals DVGW-approval requested

Media Water

Body material brass, dezincification resistant

Max. media temperature 40 oC

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Transparant strainer chamber yes

Balanced seat design yes

Additional description For closed hot water storage units up to 200 litres according to DIN 4753 Part 1 and DIN 1988. Tested to TRD 721 for 1.0 to 10.0 bar pressure range.

• Fully approved for noise level protection to class 1• Replacement insert tested to TRD 721• Pressure reducing valve with inlet pressure balancing - inlet

pressure fluctuation does not influence the outlet pressure• Easy venting• Meets KTW recommendations for potable water

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 6 SG150D-1/2AAexternal threads 3/4 20 6 SG150D-3/4AA

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 8 SG150D-1/2ABexternal threads 3/4 20 8 SG150D-3/4AB

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 10 SG150D-1/2ACexternal threads 3/4 20 10 SG150D-3/4AC

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 6 SG150D-3/4EA– – 20 6 SG150D-1/2EA

Page 492: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-9

Safety Groups

16

17

18

19

20

21

22

24

23

25

26

27

28

Without fittings, set pressure 8.0 bar

Without fittings, set pressure 10.0 bar

Accessories

Spare Parts

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 8 SG150D-3/4EB– – 20 8 SG150D-1/2EB

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 10 SG150D-3/4EC– – 20 10 SG150D-1/2EC

Reverse-rinsing filter for retro-conversion to a filter combination unit of pressure reducing valves

_FN09S

Connection set with 1/2" threaded male connections VST06-1/2A

Connection set with 3/4" threaded male connections VST06-3/4A

Connection set with 1/2" solder connections VST06-1/2B

Connection set with 3/4" solder connections VST06-3/4B

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 25 bar

M07M-A25

Pressure gauge with housing diameter 50 mm, connecting pin above G1/4", range 0 - 16 bar

M08M16

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Discharge tundish TA160S

Plug with O-ring R1/4" (packs of 5) S06K-1/4

Safety valve insert, set pressure 6 bar A152-1/2AA

Safety valve insert, set pressure 6 bar A152-3/4AA

Safety valve insert, set pressure 8 bar A152-1/2AB

Safety valve insert, set pressure 8 bar A152-3/4AB

Safety valve insert, set pressure 10 bar A152-1/2AC

Safety valve insert, set pressure 10 bar A152-3/4AC

Valve insert complete (without filter) for pressure reducing valve D06FA-1/2

Replacement filter insert for pressure reducing valve ES06F-1/2A

Filter bowl SK06TG-1/2

Page 493: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-10

Safety Groups

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Type SG160S safety groups are used to protect pressurised water heaters according to the requirements of DIN 4753, Part 1, DIN 1988 and DIN EN1488. They are compact appliances which incorporate all the necessary safety devices such as check valve, shutoff valves, test point and diaphragm type safety valve in one unit. The safety valve protects the downstream cylinder, pressure vessel etc. by automatically opening when excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of water from the hot water unit.

With threaded male connections, set pressure 6,0 bar

With threaded male connections, set pressure 8,0 bar

With threaded male connections, set pressure 10,0 bar

Without connections, set pressure 6,0 bar, DN is based on connection size of tailpiece

Safety group with interchangeable safety valve insert, SG160S

Approvals DIN/DVGW-certified

Media Water

Body material brass, dezincification resistant

Max. media temperature 40 oC

Additional description For closed water heaters in compliance with DIN 4753, Part 1 and EN 1717. Tested to TRD 721 for pressure range 1.0 bar to 10.0 bar.

• Fully approved for noise level protection to group 1• Safety valve tested to TRD 721 for the pressure range 1.0 to 10.0

bar• Easy venting• Complies with KTW requirements

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 6 SG160S-1/2AAexternal threads 3/4 20 6 SG160S-3/4AAexternal threads 1 25 6 SG160S-1AA

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 8 SG160S-1/2ABexternal threads 3/4 20 8 SG160S-3/4ABexternal threads 1 25 8 SG160S-1AB

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 10 SG160S-1/2ACexternal threads 3/4 20 10 SG160S-3/4ACexternal threads 1 25 10 SG160S-1AC

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 6 SG160S-3/4EA– – 20 6 SG160S-1EA

Page 494: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-11

Safety Groups

16

17

18

19

20

21

22

24

23

25

26

27

28

Without connections, set pressure 8,0 bar, DN is based on connection size of tailpiece

Without connections, set pressure 10,0 bar, DN is based on connection size of tailpiece

Accessories

Spare Parts

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 8 SG160S-3/4EB– – 20 8 SG160S-1EB

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 10 SG160S-3/4EC– – 20 10 SG160S-1EC

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G 1/4, range 0 - 25 bar

M07M-A25

Pressure gauge connection for SG160S 1/2" VSTM-1/2A

Pressure gauge connection for SG160S 3/4" VSTM-3/4A

Pressure gauge connection for SG160S 1" VSTM-1A

Connection set with 1/2" threaded male connections VST06-1/2A

Connection set with 3/4" threaded male connections VST06-3/4A

Connection set with 1" threaded male connections VST06-1A

Connection set with 1/2" solder connections VST06-1/2B

Connection set with 3/4" solder connections VST06-3/4B

Connection set with 1" solder connections VST06-1B

Discharge tundish TA160S

Plug with O-ring R1/4" (packs of 5) S06K-1/4

Safety valve insert, set pressure 6 bar A152-1/2AA

Safety valve insert, set pressure 6 bar A152-3/4AA

Safety valve insert, set pressure 6 bar A152-1AA

Safety valve insert, set pressure 8 bar A152-1/2AB

Safety valve insert, set pressure 8 bar A152-3/4AB

Safety valve insert, set pressure 8 bar A152-1AB

Safety valve insert, set pressure 10 bar A152-1/2AC

Safety valve insert, set pressure 10 bar A152-3/4AC

Safety valve insert, set pressure 10 bar A152-1AC

Page 495: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-12

Safety Groups

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Type SG160S safety groups are used to protect pressurised water heaters according to the requirements of DIN 4753, Part 1, DIN 1988 and DIN EN1488. They are compact appliances which incorporate all the necessary safety devices such as non return valve, shutoff valves, test point, diaphragm type safety valve and pressure reducing valve in one unit. The automatic self opening and closing of the safety valve protects the downstream hot water unit. The non return valve prevents back pressure, backflow and back syphonage of contaminated water. In addition, a balanced seat pressure reducing valve is fitted on the inlet to control the supply pressure to that required for the system.

With threaded male connections, set pressure 6,0 bar

With threaded male connections, set pressure 8,0 bar

With threaded male connections, set pressure 10,0 bar

Without connections, set pressure 6,0 bar, DN is based on connection size of tailpiece

Safety group with interchangeable safety valve insert and pressure reducing valve, SG160SD

Approvals DIN/DVGW-certified

Media Water

Body material brass, dezincification resistant

Max. media temperature 40 oC

Pressure setpoint range 1,5 ... 6 bar

Setpoint scale yes

Transparant strainer chamber yes

Balanced seat design yes

Additional description For closed water heaters in compliance with DIN 4753, Part 1 and EN 1717. Tested to TRD 721 for pressure range 1.0 bar to 10.0 bar.

• Fully approved for noise level protection to group 1• Safety valve tested to TRD 721 for the pressure range 1.0 to 10.0

bar• Balanced seat pressure reducing valve - inlet pressure fluctuations

do not influence the outlet pressure• Easy venting• Complies with KTW requirements

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 6 SG160SD-1/2AAexternal threads 3/4 20 6 SG160SD-3/4AAexternal threads 1 25 6 SG160SD-1AA

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 8 SG160SD-1/2ABexternal threads 3/4 20 8 SG160SD-3/4ABexternal threads 1 25 8 SG160SD-1AB

Port connection Port diameter DN size Set pressure Typeinch mm bar

external threads 1/2 15 10 SG160SD-1/2ACexternal threads 3/4 20 10 SG160SD-3/4ACexternal threads 1 25 10 SG160SD-1AC

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 6 SG160SD-3/4EA– – 20 6 SG160SD-1EA

Page 496: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-13

Safety Groups

16

17

18

19

20

21

22

24

23

25

26

27

28

Without connections, set pressure 8,0 bar, DN is based on connection size of tailpiece

Without connections, set pressure 10,0 bar, DN is based on connection size of tailpiece

Accessories

Spare Parts

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 8 SG160SD-3/4EB– – 20 8 SG160SD-1EB

Port connection Port diameter DN size Set pressure Typeinch mm bar

– – 20 10 SG160SD-3/4EC– – 20 10 SG160SD-1EC

Connection set with 1/2" threaded male connections VST06-1/2A

Connection set with 3/4" threaded male connections VST06-3/4A

Connection set with 1" threaded male connections VST06-1A

Connection set with 1/2" solder connections VST06-1/2B

Connection set with 3/4" solder connections VST06-3/4B

Connection set with 1" solder connections VST06-1B

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 4 bar

M07M-A4

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 10 bar

M07M-A10

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 16 bar

M07M-A16

Pressure gauge with housing diameter 63 mm, rear connection thread G1/4", range 0 - 25 bar

M07M-A25

Pressure gauge connection for SG160S 1/2" VSTM-1/2A

Pressure gauge connection for SG160S 3/4" VSTM-3/4A

Pressure gauge connection for SG160S 1" VSTM-1A

Double ring wrench for removal of spring bonnet and filter bowl ZR06K

Discharge tundish TA160S

Plug with O-ring R1/4" (packs of 5) S06K-1/4

Safety valve insert, set pressure 6 bar A152-1/2AA

Safety valve insert, set pressure 6 bar A152-3/4AA

Safety valve insert, set pressure 6 bar A152-1AA

Safety valve insert, set pressure 8 bar A152-1/2AB

Safety valve insert, set pressure 8 bar A152-3/4AB

Safety valve insert, set pressure 8 bar A152-1AB

Safety valve insert, set pressure 10 bar A152-1/2AC

Safety valve insert, set pressure 10 bar A152-3/4AC

Safety valve insert, set pressure 10 bar A152-1AC

Valve insert complete (without filter) for pressure reducing valve D06FA-1/2

Valve insert complete (without filter) for pressure reducing valve D06FA-1A

Replacement filter insert for pressure reducing valve ES06F-1/2A

Clear filter bowl with O-ring for pressure reducing valve SK06TG-1/2

Page 497: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-14

Safety Groups

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16SG162 safety groups are controls to DIN 4753 Part 1 and DIN 1988 for the protection of pressurised hot water storage units with capacities up to 200 litres. They are composite assemblies which integrate in one unit all necessary safety components, including check valve, shutoff valve, test point and diaphragm-type safety valve. The safety valve protects the downstream cylinder, pressure vessel etc. by automatically opening when excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of water from the hot water unit.

Safety valve opening pressure 6,0 bar

Safety valve opening pressure 10,0 bar

Accessories

Spare Parts

SECURA-Safety group for pressurised hot water storage units up to 200 litres, SG162

Approvals TUEV approved, certified to Pressure Equipment Directive 97/23/EG, Reference No. CE 0035.

Media Water

Body material brass, dezincification resistant

Body finishing chrome plated

Port diameter 1/2 inch

DN size 15 mm

Max. media temperature 70 oC

Additional description For closed hot water storage units up to 200 litres according to DIN 4753 Part 1 and EN 1717. Tested to TRD 721 for 1.0 to 10.0 bar pressure range.

• The venting device can be easily serviced• Can be fitted on the left or right• Housing and connection pipes are chrome plated• The pressure reducing valve can be retro fitted• Complies with drinking water requirements

Set pressure Typebar

6 SG162-1/2A

Set pressure Typebar

10 SG162-1/2C

Pressure reducing valve D162-1/2A

Safety valve insert, set pressure 6 bar A162-BA

Safety valve insert, set pressure 10 bar A162-BC

Page 498: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-15

Safety Groups

16

17

18

19

20

21

22

24

23

25

26

27

28

SG162D safety groups are safety controls to DIN 4753 Part 1 and DIN 1988 for the protection of pressurised hot water storage units with capacities up to 200 litres. They are composite assemblies which integrate in one unit all necessary safety components, including check valve, shutoff valve, test point and diaphragm-type safety valve. The safety valve protects the down-stream cylinder, pressure vessel etc. by automatically opening when excess pressure occurs. The check valve prevents back pressure, backflow and back syphonage of water from the hot water unit. In addition, a balanced-seat pressure reducing valve is fitted on the inlet and this reduces the pressure from the inlet supply to the pressure required for the system. It also prevents uncontrolled dripping from the safety valve when the inlet pressure fluctuates.

Safety valve opening pressure 6,0 bar

Safety valve opening pressure 10,0 bar

Spare Parts

Safety group with pressure reducing valve for pressurised hot water storage units up to 200 litres, SG162D

Approvals TUEV approved, certified to Pressure Equipment Directive 97/23/EG, Reference No. CE 0035.

Media Water

Body material brass, dezincification resistant

Body finishing chrome plated

Port diameter 1/2 inch

DN size 15 mm

Max. media temperature 70 oC

Balanced seat design yes

Additional description For closed hot water storage units up to 200 litres according to DIN 4753 Part 1 and EN 1717. Tested to TRD 721 for 1.0 to 10.0 bar pressure range.

• The venting device can be easily serviced• Can be fitted on the left or right• Housing and connection pipes are chrome plated• The pressure reducing valve can be retro fitted• The pressure reducing valve provides inlet pressure compensation

- inlet pressure fluctuations have no influence on the outlet pressure

Set pressure Typebar

6 SG162D-1/2A

Set pressure Typebar

10 SG162D-1/2C

Safety valve insert, set pressure 6 bar A162-BA

Safety valve insert, set pressure 10 bar A162-BC

Pressure reducing valve D162-1/2A

Page 499: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-16

Thermostatic Mixing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Thermostatic Mixing Valves

TM50 thermostatic mixing valves provide control of the water temperature and are used: - For centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor heating or for limiting boiler return temperatures. Where a system includes a hot water circulation circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water backfeeding and cooling the mixed water at the outlets.

With check valve on inlet ports

Accessories

Thermostatic mixing valve with scald protection, TM50

Media Water

Body material brass, dezincification resistant

Port connection external threads

Max. media temperature 90 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet temperature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• Options with integrated check valves for cold and hot water inlet

available• Inner components are of scale-resistant materials

TypeTM50-1/2E

TypeTM50-1/2ERV

Return flow-retarder unit for fitting to systems which include a hot water circulation circuit - to prevent cold water backfeeding and cooling the mixed water at the outlets

KB191-3/4

Page 500: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-17

Thermostatic Mixing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Thermostatic mixing valves of this type are used for central regulation of the water temperature in solar-powered, bivalent water heaters.A cold water break can be fitted in the circulation line in water heater systems, which prevents cold water from mixing at the extraction point via the circulation line.

With check valve

Thermostatic mixing valve with scald protection for solar installations, TM50SOLAR

Media Water

Body material brass, dezincification resistant

Body finishing nickel plated

Port connection external threads

Max. media temperature 110 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water-temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet tempe-rature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• With integrated check valves, TM50SOLAR-1/2 ERV only• Meets KTW recommendations for potable water• Inner components are of scale-resistant materials

TypeTM50SOLAR-1/2E

TypeTM50SOLAR-1/2ERV

Page 501: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-18

Thermostatic Mixing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16TM200 thermostatic mixing valves provide control of the water temperature and are used: - For centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor heating or for limiting boiler return temperatures. Where a system includes a hot water circulation circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water backfeeding and cooling the mixed water at the outlets.

With threaded male connections 3/4 inch

With 22 mm soldered connections

Accessories

Spare Parts

Thermostatic mixing valve with scald protection, TM200

Media Water

Body material brass

Max. media temperature 90 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet temperature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• Inner components are of scale-resistant materials

Port connection Typeexternal threads TM200-3/4A

Port connection Typesoldering TM200-3/4B

Return flow-retarder unit for fitting to systems which include a hot water circulation circuit - to prevent cold water backfeeding and cooling the mixed water at the outlets

KB191-3/4

Control piston with integral sensing element TM200A-30/60

Page 502: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-19

Thermostatic Mixing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Thermostatic mixing valves of this type are used for central regulation of the water temperature in solar-powered, bivalent water heaters.A cold water break can be fitted in the circulation line in water heater systems, which prevents cold water from mixing at the extraction point via the circulation line.

With threaded union connectors

Without connection fittings

Thermostatic mixing valve with scald protection for solar installations, TM200SOLAR

Media Water

Body material brass, dezincification resistant

Body finishing nickel plated

Port connection external threads

Max. media temperature 110 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water-temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet tempe-rature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• Meets KTW recommendations for potable water• Inner components are of scale-resistant materials

TypeTM200SOLAR-3/4A

TypeTM200SOLAR-3/4E

Page 503: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-20

Thermostatic Mixing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16TM300 thermostatic mixing valves provide control of the water temperature and are used: - For centralised control on hot water supply units or for localised control adjacent to point-use outlets. Or for use with solar-heated hot water units with dual energy source. - In heating systems with underfloor heating or for limiting boiler return temperatures. Where a system includes a hot water circulation circuit, a KB191 return flow retarder unit (see accessories) must be fitted to prevent cold water backfeeding and cooling the mixed water at the outlets.

With 28 mm compression fitting, 44 degree C setting

With 22 mm compression fitting, 38 degree C setting, TMV 2 approved

Accessories

Thermostatic mixing valves of this type are used for central regulation of the water temperature in solar-powered, bivalent water heaters.A cold water break can be fitted in the circulation line in water heater systems, which prevents cold water from mixing at the extraction point via the circulation line.

With threaded union connectors

Thermostatic mixing valve with scald protection, TM300

Media Water

Body material brass

Port connection coupling compressing fitting

Max. media temperature 90 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet temperature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• Inner components are of scale-resistant materials• With inlet check valves

TypeTM300-3/4I

TypeTM300-3/4H

Return flow-retarder unit for fitting to systems which include a hot water circulation circuit - to prevent cold water backfeeding and cooling the mixed water at the outlets

KB191-3/4

Thermostatic mixing valve with scald protection for solar installations, TM300SOLAR

Media Water

Body material brass, dezincification resistant

Body finishing nickel plated

Port connection external threads

Max. media temperature 110 oC

Temp. setpoint range 30 ... 60 oC

Additional description • Highly sensitive thermal element with good all-round water-temperature sensing, even at low flow rates

• Simple setting of the required water temperature• Scald protection - the hot water inlet is automatically cut off if the

cold supply fails provided that the hot water inlet tempe-rature is at least 10 K higher than that of mixed water setting

• The cold water inlet is automatically cut off if the hot supply fails• Meets KTW recommendations for potable water• Inner components are of scale-resistant materials

TypeTM300SOLAR-3/4A

Page 504: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-21

Thermostatic Mixing Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Standard thermostatic mixing valves TM3400/TM3410 are used in domestic hot water central heating systems with or without recirculation. The aim is to maintain a constant temperature of the mixed water for users, by varying the temperature of the hot water stored. Thermostatic mixing valves also have applications in underfloor heating applications and in alternative energy systems, such as solar and woodchip systems.

Setting range 20...30 C Set during manufacture 25 C

Setting range 30...45 C Set during manufacture 40 C

Setting range 36...53 C Set during manufacture 48 C

Thermostatic mixing valve with scald protection, TM3400/TM3410

Media Water

Body material red bronze RG5

Additional description • Wide flow• Lightness• High degree of adjustment precision• Scald protection• Works without external energy• Direct connection to recicrculation circuit (except 1/2") • Complete with female inlet couplings

Temp. setpoint range Connection diameter Port connection TypeoC inch

20 ... 30 1/2" external threads TM3400.91020 ... 30 3/4" external threads TM3400.92020 ... 30 1 external threads TM3400.93020 ... 30 11/4" external threads TM3400.94020 ... 30 11/2" external threads TM3400.95020 ... 30 2 external threads TM3400.96020 ... 30 DN65 flanges TM3410.60120 ... 30 DN80 flanges TM3410.801

Temp. setpoint range Connection diameter Port connection TypeoC inch

30 ... 45 1/2" external threads TM3400.91230 ... 45 3/4" external threads TM3400.92230 ... 45 1 external threads TM3400.93230 ... 45 11/4" external threads TM3400.94230 ... 45 11/2" external threads TM3400.95230 ... 45 2 external threads TM3400.96230 ... 45 DN65 flanges TM3410.60530 ... 45 DN80 flanges TM3410.805

Temp. setpoint range Connection diameter Port connection TypeoC inch

36 ... 53 1/2" external threads TM3400.91436 ... 53 3/4" external threads TM3400.92436 ... 53 1 external threads TM3400.93436 ... 53 11/4" external threads TM3400.94436 ... 53 11/2" external threads TM3400.95436 ... 53 2 external threads TM3400.96436 ... 53 DN65 flanges TM3410.60636 ... 53 DN80 flanges TM3410.806

Page 505: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

21-22

Thermostatic Mixing Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16 Setting range 45...65 C Set during manufacture 55 C

Temp. setpoint range Connection diameter Port connection TypeoC inch

45 ... 65 1/2" external threads TM3400.91645 ... 65 3/4" external threads TM3400.92645 ... 65 1 external threads TM3400.93645 ... 65 11/4" external threads TM3400.94645 ... 65 11/2" external threads TM3400.95645 ... 65 2 external threads TM3400.96645 ... 65 DN65 flanges TM3410.60845 ... 65 DN80 flanges TM3410.808

Page 506: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Control Valves, residential/industrial Page

Control Valves, industrial 22-2Control Valves, universal 22-17

Page 507: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-2

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Control Valves, industrial

The basic valves are used as shutoff valves. They may be controlled by the common medium or by an external medium using the integral control valve. A manual, electro-magnetic solenoid or float valve can be used as the control valve. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request

Spare Parts

Basic valve, BV300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow rate• Light weight and compact construction• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe

DN size Flow capacity Kvs Typemm

50 43 BV300-50A65 43 BV300-65A80 103 BV300-80A

100 167 BV300-100A150 407 BV300-150A200 676 BV300-200A250 1160 BV300-250A300 1600 BV300-300A350 1600 BV300-350A400 3300 BV300-400A450 3300 BV300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Page 508: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-3

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

DH300 pressure sustaining valves are regulators which control the pressure on the inlet side. They are used wherever a specific inlet pressure must not be exceeded, for example limiting the pressure in the inlet supply network or in transition links between supply networks and high demand large users. Their compact construction makes them ideally suited for applications where space is limited, for example in ducts. They can be used for commercial or industrial applications within the scope of their specification.

Flanges, PN 16, ISO 2084; PN 25, ISO 2441 on request

Spare Parts

Pressure sustaining valve, DH300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Pressure setpoint range 1 ... 12 bar

Additional description • High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves• Replaceable valve seat

DN size Flow capacity Kvs Typemm

50 43 DH300-50A65 43 DH300-65A80 103 DH300-80A

100 167 DH300-100A150 407 DH300-150A200 676 DH300-200A250 1160 DH300-250A300 1600 DH300-300A350 1600 DH300-350A400 3300 DH300-400A450 3300 DH300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-PS

Pressure gauge M07M-A16

Page 509: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-4

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure regulators of this type protect downstream installations against excessive supply pressure. Pressure regulators are used when the capacity of direct controlled pressure reducing valves are insufficient. Their compact construction makes them particularly suitable for installation in limited spaces, for example in ducts. By using a pressure regulator, pressurization damage is avoided and water consumption reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation.

Flanges, PN 16, ISO 2084

Pressure regulator, DR300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Pressure setpoint range 1 ... 12 bar

Additional description • High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves• No external energy required for operation

DN size Flow capacity Kvs Typemm

50 43 DR300-50A65 43 DR300-65A80 103 DR300-80A

100 167 DR300-100A150 407 DR300-150A200 676 DR300-200A250 1160 DR300-250A300 1600 DR300-300A350 1600 DR300-350A400 3300 DR300-400A450 3300 DR300-450A

Page 510: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-5

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

Flanges, PN 25, ISO 2084

Spare Parts

DN size Flow capacity Kvs Typemm

50 43 DR300-50B65 43 DR300-65B80 103 DR300-80B

100 167 DR300-100B150 407 DR300-150B200 676 DR300-200B250 1160 DR300-250B300 1600 DR300-300B350 1600 DR300-350B400 3300 DR300-400B450 3300 DR300-450B

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-PR

Pressure gauge M07K-A16

Page 511: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-6

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The FD300 attitude control valve controls the water level in, for example, water reservoirs without the need for using a float valve or other ancillary controls. The highly sensitive pilot valve and the main valve are installed outside the water reservoir and the pilot valve senses the hydrostatic water pressure from the water level in the reservoir. The main valve closes when the maximum set pressure for the pilot valve is reached and reopens when the water level corresponds to the lower set value on the pilot valve. The standard version permits filling of a water storage unit. A special version is also available on request which can be used for both filling and emptying water storage units.

Housing with flange, PN 16; PN 25 on request

Spare Parts

Attitude control valve, FD300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description Setting range 0.5 - 5 m water head (Standard version)• High flow rate• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 FD300-50A65 43 FD300-65A80 103 FD300-80A

100 167 FD300-100A150 407 FD300-150A200 676 FD300-200A250 1160 FD300-250A300 1600 FD300-300A350 1600 FD300-350A400 3300 FD300-400A450 3300 FD300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes 76-600

Page 512: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-7

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

The FV300 filling valve can be used in water supplies and for industrial and commercial applications for the filling of reservoirs, tanks and cisterns. It is controlled by the main storage medium via a float valve and impulse link pipework. The FV300 filling valve is prevented from filling constantly by the use of a pilot valve, which can be adjusted to provide varying fill level differentials for opening and closing the valve.

Housing with flange, PN 16; PN 25 on request

Spare Parts

Accessories

Filling valve, FV300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Additional description Switching level differential 5 - 160 cm with pilot float valve 70-550 or 5 - 40 cm with pilot float valve 70-610. Please order pilot float valves separately. Minimum inlet pressure 0.7 bar + pressure resulting from differential in physical height of the impulse link pipe.

• High flow capacity• Light weight and compact construction• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size (mm) Flow capacity Kvs Type50 43 FV300-50A65 43 FV300-65A80 103 FV300-80A

100 167 FV300-100A150 407 FV300-150A200 676 FV300-200A250 1160 FV300-250A300 1600 FV300-300A350 1600 FV300-350A400 3300 FV300-400A450 3300 FV300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Pilot float valve, level switching differential 5 - 160 cm, for all sizes 70-550

Pilot float valve, level switching differential 5 - 40 cm, for all sizes 70-610

Pilot float valve, level switching differential 5 - 160 cm, for all sizes 70-550

Pilot float valve, level switching differential 5 - 40 cm, for all sizes 70-610

Page 513: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-8

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Type MV300 magnetic solenoid valves are mainly used as shutoff valves. They are controlled by the integral magnetic solenoid operated valve. Their compact design makes them ideally suited where space is limited, for example in ducts. Within the scope of their specification they can be used on industrial and commercial applications.

Flanges, PN 16, ISO 2084, Magnetic solenoid pilot valve 230 V/50 Hz closed when electrical supply off; PN 25, ISO 2441 on request

Flanges, PN 16, ISO 2084, Magnetic solenoid pilot valve 230 V/50 Hz open when electrical supply off; PN 25, ISO 2441 on request

Magnetic solenoid valve, MV300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow capacity• Fitting of impulse link pipework is not necessary• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 MV300-50A65 43 MV300-65A80 103 MV300-80A

100 167 MV300-100A150 407 MV300-150A200 676 MV300-200A250 1160 MV300-250A300 1600 MV300-300A350 1600 MV300-350A400 3300 MV300-400A450 3300 MV300-450A

DN size Flow capacity Kvs Typemm

50 43 MV300-50AA65 43 MV300-65AA80 103 MV300-80AA

100 167 MV300-100AA150 407 MV300-150AA200 676 MV300-200AA250 1160 MV300-250AA300 1600 MV300-300AA350 1600 MV300-350AA400 3300 MV300-400AA450 3300 MV300-450AA

Page 514: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-9

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

Flanges, PN 16, ISO 2084, Magnetic solenoid pilot valve 24 V/50 Hz closed when electrical supply off; PN 25, ISO 2441 on request

Flanges, PN 16, ISO 2084, Magnetic solenoid pilot valve 24 V/50 Hz open when electrical supply off; PN 25, ISO 2441 on request

Spare Parts

DN size Flow capacity Kvs Typemm

50 43 MV300-50B65 43 MV300-65B80 103 MV300-80B

100 167 MV300-100B150 407 MV300-150B200 676 MV300-200B250 1160 MV300-250B300 1600 MV300-300B350 1600 MV300-350B400 3300 MV300-400B450 3300 MV300-450B

DN size Flow capacity Kvs Typemm

50 43 MV300-50BB65 43 MV300-65BB80 103 MV300-80BB

100 167 MV300-100BB150 407 MV300-150BB200 676 MV300-200BB250 1160 MV300-250BB300 1600 MV300-300BB350 1600 MV300-350BB400 3300 MV300-400BB450 3300 MV300-450BB

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement magnetic solenoid valve, 230 V/50 Hz, normally closed 0903761

Replacement magnetic solenoid valve, 24 V/50 Hz, normally closed 0903762

Page 515: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-10

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The PC300 surge anticipating valve for pumped systems is used for the prevention of negative pressure and water pressure shocks in long pumped pipework systems caused by sudden pump shut-off (e.g. from power failure).

Housing with flange, PN 16; PN 25 on request

Spare Parts

Surge anticipating valve, PC300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

65 43 PC300-65A80 103 PC300-80A

100 167 PC300-100A150 407 PC300-150A200 676 PC300-200A250 1160 PC300-250A300 1600 PC300-300A350 1600 PC300-350A400 3300 PC300-400A450 3300 PC300-450A

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes 66-300

Pressure gauge M39M-A16

Page 516: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-11

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

The PS300 valve is used as a protection valve in pressure boosting systems to provide a water hammer free shutdown and start-up of pumps.

Housing with flange, PN 16, ISO 7005, EN 1092-2; PN 25 on request

Spare Parts

Pump control valve, PS300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow capacity• Light weight and compact construction• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 PS300-50A65 43 PS300-65A80 103 PS300-80A

100 167 PS300-100A150 407 PS300-150A200 676 PS300-200A250 1160 PS300-250A300 1600 PS300-300A350 1600 PS300-350A400 3300 PS300-400A450 3300 PS300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement magnetic solenoid valve, 24 V AC, normally closed 0903763

End switch 0903764

Page 517: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-12

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The quick relief SV300 safety valve is controlled by the medium flowing through it via a pilot valve.It is preferably installed in branches of supply pipework and protects downstream parts of a system which are at risk from unacceptable excess pressure which can, for example, be caused by pumps. If the inlet pressure to the valve rises up to the set opening pressure, then the valve opens immediately to the maximum flow position. If the pressure falls to the set pressure, then the valve closes slowly to prevent pressure shock loads.

Housing with flange, PN 16, ISO 7005, EN 1092-2; PN 25 on request

Spare Parts

Safety valve, SV300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description Opening pressure 1 - 7 bar adjustable.• High flow capacity• Light weight and compact construction• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 SV300-50A65 43 SV300-65A80 103 SV300-80A

100 167 SV300-100A150 407 SV300-150A200 676 SV300-200A250 1160 SV300-250A300 1600 SV300-300A350 1600 SV300-350A400 3300 SV300-400A450 3300 SV300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-PS

Page 518: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-13

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

The protection valve for deep well pumping is used to permit pressure shock free starting and stopping of deep well pumps.

Housing with flange, PN 16, ISO 7005, EN 1092; PN 25 on request

Spare Parts

Protection valve for deep well pumping, TC300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow capacity• Light weight and compact construction• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 TC300-50A65 43 TC300-65A80 103 TC300-80A

100 167 TC300-100A150 407 TC300-150A200 676 TC300-200A250 1160 TC300-250A300 1600 TC300-300A350 1600 TC300-350A400 3300 TC300-400A450 3300 TC300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement magnetic solenoid valve, normally closed 0903765

Replacement magnetic solenoid valve, normally open 0903766

Page 519: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-14

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16A flow rate regulator, also called a flow rate limiting valve, controls to a fixed flow rate, independent of fluctuating operating pressures and take-off flow rates. It prevents, for example, pumps running at too high a performance or regulates the performance of whole installations and systems.

Housing with flange, PN 16, ISO 7005, EN 1092-2; PN 25 on request

Spare Parts

Flow rate regulator, VR300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description • High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 VR300-50A65 43 VR300-65A80 103 VR300-80A

100 167 VR300-100A150 407 VR300-150A200 676 VR300-200A250 1160 VR300-250A300 1600 VR300-300A350 1600 VR300-350A400 3300 VR300-400A450 3300 VR300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-FR

Page 520: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-15

Control Valves, industrial

16

17

18

19

20

21

22

24

23

25

26

27

28

VV300 priority valves are a combination between pressure regulating and pressure limiting valves. They are used to ensure priority drinking water supply to important systems. Ancillary systems are then supplied only when there is sufficient surplus drinking water available. In addition downstream installations are protected against excess supply pressures. The compact construction makes them particularly suitable for applications where space is limited, for example in ducts. The application of priority valves prevents pressure damage. The set pressure remains constant even when the inlet pressure fluctuates greatly.

Housing with flange, PN 16, ISO 7005, EN 1092-2; PN 25 on request

Spare Parts

Priority valve, VV300

Media Water

Body material spherulitic cast iron GGG40

Body finishing powder coating

Port connection flanges

Max. media temperature 80 oC

Pressure rating PN16

Minimum inlet pressure 0,7 bar

Additional description Opening pressure, pilot valve CX-PS 1 - 12 bar. Outlet pressure, pilot valve CX-PR 1 - 12 bar.

• High flow capacity• High control accuracy• Powder coated inside and outside - Powder used is

physiologically and toxicologically safe• Integral control circuit and ball valves

DN size Flow capacity Kvs Typemm

50 43 VV300-50A65 43 VV300-65A80 103 VV300-80A

100 167 VV300-100A150 407 VV300-150A200 676 VV300-200A250 1160 VV300-250A300 1600 VV300-300A350 1600 VV300-350A400 3300 VV300-400A450 3300 VV300-450A

Seal Set for DN 50 0903750

Seal Set for DN 65 0903751

Seal Set for DN 80 0903752

Seal Set for DN 100 0903753

Seal Set for DN 150 0903754

Seal Set for DN 200 0903755

Seal Set for DN 250 0903756

Seal Set for DN 300 0903757

Seal Set for DN 350 0903758

Seal Set for DN 400 0903759

Seal Set for DN 450 0903760

Replacement pilot valve for all sizes CX-PR

Replacement pilot valve for all sizes CX-PS

Pressure gauge M07M-A16

Page 521: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-16

Control Valves, industrial

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16VR 170 float valves regulate a fluid level in vented open or closed storage vessels or can be used for filling of water supply storage tanks. Within the scope of their specification they can be used for industrial or commercial installations or also for public water supply systems. A soft seat seal provides positive shutoff, even with fluctuating supply pressure.

Standard version

Stainless steel float for VR 170

Plastic float for VR 170

Float valve for water storage tanks, VR 170

Media Water and neutral liquids

Additional description • Available with plastics or stainless steel floats• Float can be fitted horizontally or vertically• Open construction design• Seat seal and piston replaceable• Lever arm can be shortened where supply pressure is low

Body material Port connection Port diameter Max. media temperature Typeinch oC

brass external threads 1/2 – VR170-1/2Abrass external threads 3/4 – VR170-3/4Abrass external threads 1 – VR170-1Abrass external threads 1 1/4 – VR170-11/4Abrass external threads 1 1/2 – VR170-11/2Abrass external threads 2 – VR170-2A

red bronze RG5 external threads 2 1/2 – VR170-21/2A

Body material Port connection Port diameter Max. media temperature Typeinch oC

stainless steel – – 90 ZN170-1/2Astainless steel – – 90 ZN170-3/4Astainless steel – – 90 ZN170-1Astainless steel – – 90 ZN170-11/4Astainless steel – – 90 ZN170-11/2Astainless steel – – 90 ZN170-2Astainless steel – – 90 ZN170-21/2Astainless steel – – 90 ZN170-3A

Body material Port connection Port diameter Max. media temperature Typeinch oC

synthetic material – – 65 Z171T-1/2Asynthetic material – – 65 Z171T-11/4A

Page 522: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-17

Control Valves, universal

16

17

18

19

20

21

22

24

23

25

26

27

28

Control Valves, universal

Throttle and shut-off valve for potable water circulation loops for balancing according to DVGW worksheets W551 and W552. Retrofittable automatic temperature control with support of thermal disinfection. Draining support with adapter (accessory). Valve housing without side connections for easy insulation. Cavity-free insert with maintenance-free spindle sealing. Handwheel thread isolated from the flow. Visible digital pre-setting dial with concealed pre-setting ring. Very precise due to factory calibration.For potable water circulation systems.

Alwa-Kombi-4 with external threads

Alwa-Kombi-4 with internal threads

Alwa-Kombi-4 with fitted Mapress fittings

Alwa-Kombi-4 (V1800) Circulation throttle valve

Approvals DVGW approved, conforms with KTW requirements

Materials Valve housing and all parts with contact to the flow made of corrosion resistant red bronze

Body pattern Y-pattern

Pre-setting yes

Position indication Visible, digital pre-setting display with concealed pre-setting ring

Automatic balancing support

yes

Draining/filling support yes

Integrated non-return device

no

Max. media temperature 130 oC

Pressure rating PN16

Additional description Suitable connections see 'Connections for Alwa-valves'.

DN size Port diameter Connection size Port connection Kvs value Typemm inch mm

15 G3/4 – external threads 2,7 V1810X001520 G1 – external threads 6,4 V1810X002025 G1 1/4 – external threads 6,8 V1810X002532 G1 1/2 – external threads 16 V1810X003240 G1 3/4 – external threads 16 V1810X0040

DN size Port diameter Connection size Port connection Kvs value Typemm inch mm

15 R1/2 – internal threads 2,7 V1810Y001520 R3/4 – internal threads 6,4 V1810Y002025 R1 – internal threads 6,8 V1810Y002532 R1 1/4 – internal threads 16 V1810Y003240 R1 1/2 – internal threads 16 V1810Y0040

DN size Port diameter Connection size Port connection Kvs value Typemm inch mm

15 – 15 Mapress fittings 2,7 V1816Y001515 – 18 Mapress fittings 2,7 V1816Y001820 – 22 Mapress fittings 6,4 V1816Y002025 – 28 Mapress fittings 6,8 V1816Y002532 – 35 Mapress fittings 16 V1816Y003240 – 42 Mapress fittings 16 V1816Y0040

Page 523: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-18

Control Valves, universal

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16 Alwa-Kombi-4 with fitted Sanpress fittings

Accessories

The Alwa-KFR is used as shut-off valve with backflow preventer in potable water installations. The downstream installation is isolated by shutting off the valve with the handwheel. The integral backflow preventer with an opening pressure of <=10 mbar stops water from flowing back through the valve. The valve insert with integrated backflow preventer is available as spare part and fits into all valve housings with dimensions according to DVGW so that normal shut-off valves can be upgrated to shut-off valves with backflow preventer. Alwa-KFR valves are available with various pipe connections. Alwa-K-KFR valves are equipped with larger external threads specially suitable for pipe connections of various plastic pipes. Valves with draining facility allow draining of the system over the valve. For potable water systems.

Alwa-KFR with internal threads

DN size Port diameter Connection size Port connection Kvs value Typemm inch mm

15 – 15 Sanpress fittings 2,7 V1817Y001515 – 18 Sanpress fittings 2,7 V1817Y001820 – 22 Sanpress fittings 6,4 V1817Y002025 – 28 Sanpress fittings 6,8 V1817Y002532 – 35 Sanpress fittings 16 V1817Y003240 – 42 Sanpress fittings 16 V1817Y0040

Temperature-controlled actuator for 50...60 degree C (122...140 degree F) temperature range, conforms with DVGW, W551 and W552

VA2400A002

Temperature-controlled actuator for 40...65 degree C (104...149 degree F) temperature range

VA2400B002

Draining adapter VA3400A001

Thermometer TH07K

Insulation shells, for valves DN10 and DN15 VA2510C015

Insulation shells, for valves DN20 VA2510C020

Insulation shells, for valves DN25 VA2510C025

Insulation shells, for valves DN32 VA2510C032

Insulation shells, for valves DN40 VA2510C040

Insulation shells, for valves DN50 VA2510C050

Sampling valve. For all sizes. Only in conjunction with drain adapter VA3400A001 VA3400C001

Alwa-KFR (V4120) Shutoff valve with integrated backflow preventer

Approvals Alwa-KFR are DVGW-certified under registration-no. NW-6130AS2114 and low noise according to DIN 4109.

Materials All parts with contact to the flow made of corrosion resistant red bronze, stainless steel or plastic

Body pattern Y-pattern

Integrated non-return device

yes

Max. media temperature 90 oC

Pressure rating PN16

Additional description Suitable connections see 'Connections for Alwa-valves'.

DN size Port diameter Port connection Kvs value Typemm inch

15 R1/2 internal threads 5,1 V4120YY01520 R3/4 internal threads 10,6 V4120YY02025 R1 internal threads 17,1 V4120YY02532 R1 1/4 internal threads 29 V4120YY03240 R1 1/2 internal threads 35,1 V4120YY04050 R2 internal threads 64,5 V4120YY050

Page 524: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-19

Control Valves, universal

16

17

18

19

20

21

22

24

23

25

26

27

28

Alwa-KFR with external threads

Alwa-KFR with internal thread on inlet and external thread on outlet

Alwa-KFR draining valve with chain and cap

Alwa-K-KFR with external threads for plastic pipe

Alwa-F-KFR with flanges, DN15 to DN80 with blind plug, DN100 with closed valve body

DN size Port diameter Port connection Kvs value Typemm inch

15 G3/4 external threads 5,1 V4120XX01520 G1 external threads 10,6 V4120XX02025 G1 1/4 external threads 17,1 V4120XX02532 G1 1/2 external threads 29 V4120XX03240 G1 3/4 external threads 35,1 V4120XX04050 G2 3/8 external threads 64,5 V4120XX05065 G3 external threads 88,5 V4120XX06580 G3 1/2 external threads 129 V4120XX080

DN size Port diameter Port connection Kvs value Typemm inch

15 R1/2+G3/4 internal and external threads 5,1 V4120YX01520 R3/4+G1 internal and external threads 10,6 V4120YX02025 R1+G1 1/4 internal and external threads 17,1 V4120YX02532 R1 1/4+G1 1/2 internal and external threads 29 V4120YX03240 R1 1/2+G1 3/4 internal and external threads 35,1 V4120YX04050 R2+G2 3/8 internal and external threads 64,5 V4120YX050

DN size Port diameter Port connection Kvs value Typemm inch

15 R1/2 internal threads 5,1 V4119YX01520 R3/4 internal threads 10,6 V4119YX020

DN size Port diameter Port connection Kvs value Typemm inch

15 G1 external threads 5,1 V4120KK01520 G1 1/4 external threads 10,6 V4120KK02025 G1 1/2 external threads 17,1 V4120KK02532 G2 external threads 29 V4120KK03240 G2 1/4 external threads 35,1 V4120KK04050 G2 3/4 external threads 64,5 V4120KK050

DN size Port diameter Port connection Kvs value Typemm inch

15 – flanges 5,1 V4120FF01520 – flanges 10,6 V4120FF02025 – flanges 17,1 V4120FF02532 – flanges 29 V4120FF03240 – flanges 35,1 V4120FF04050 – flanges 64,5 V4120FF05065 – flanges 132 V4120FF06580 – flanges 193 V4120FF080

100 – flanges 251 V4120FF100

Page 525: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

22-20

Control Valves, universal

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Service parts

Accessories

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN15

VS1401B015

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN20

VS1401B020

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN25

VS1401B025

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN32

VS1401B032

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN40

VS1401B040

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN50

VS1401B050

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN65 (opening pressure 150 mbar)

VS1401A065

Valve insert with integrated backflow preventer for all valve housings to DVGW, for DN80 (opening pressure 150 mbar)

VS1401A080

Handwheel, red, for DN15 to DN20 VS2400B050

Handwheel, red, for DN25 to DN50 VS2400B080

Handwheel, red, for DN65 to DN80 VS2400B120

Draining valve, for DN15, DN20 and DN25 VA3401A008

Draining valve, for DN32, DN40, DN50, DN65 and DN80 VA3401A010

Insulation shells, for valves DN15 VA2510C015

Insulation shells, for valves DN20 VA2510C020

Insulation shells, for valves DN25 VA2510C025

Insulation shells, for valves DN32 VA2510C032

Insulation shells, for valves DN40 VA2510C040

Insulation shells, for valves DN50 VA2510C050

Sampling valve with connection size G1/4 for building valves up to DN25 VA4250A008

Sampling valve with connection size G3/8 for building valves from DN32 to DN80 VA4250A010

Page 526: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Thermostats Page

Electronic Thermostats 23-2Standard Thermostats 23-4Thermostats, component-tested 23-8Thermostats with ATEX approval 23-14

Page 527: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-2

Electronic Thermostats

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Electronic Thermostats

Electronic thermostats, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of heating elements, furnaces, heating units, and process temperatures, as well as for applications in the field of frost protection.Models available with the following output types:

• all models: switch output open collector; 15...36 Vdc, 250 mA• TST-series: transmitter output; 0...10 Vdc or 4...20 mA• TST...R-series: relay output with gold plated SPDT contact

Switch + Transmitter, TST...-models

Switch + Transmitter + Relay, TST...R-models

Electronic thermostats (SmartTemp)

Protection class IP65

Housing material polybutylene terephtalate (PBT)

Ambient temperature -20 ... 60 oC

Optional functions • Applicable parameter settings:• switching Set / Reset points• filters• analog output range• electrical drag indicator• Applicable configurations:• Max-Min, Window monitor• Analog output signal• Temperature unit• Simulation mode• Plugs have to be ordered separately !

Temp. setpoint range Immersion depth Model TypeoC mm

-50 ... 50 100 line length: built on TST050G12100-50 ... 50 250 line length: built on TST050G12250

-50 ... 200 100 line length: built-on neck-tube TST200G12100-50 ... 200 250 line length: built-on neck-tube TST200G12250-50 ... 200 – line length: external TST200EPT1K-50 ... 400 – line length: external TST400EPT1K

Temp. setpoint range Immersion depth Model TypeoC mm

-50 ... 50 100 line length: built on TST050G12100-R-50 ... 50 250 line length: built on TST050G12250-R

-50 ... 200 100 line length: built-on neck-tube TST200G12100-R-50 ... 200 250 line length: built-on neck-tube TST200G12250-R-50 ... 200 – line length: external TST200EPT1K-R-50 ... 400 – line length: external TST400EPT1K-R

Page 528: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-3

Electronic Thermostats

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4)

Accessories / Immersion Tubes

Accessories / Other

External Sensors

5-prong M12 plug connector, angled version ST12-5-A

5-prong M12 plug connector, straight version ST12-5-G

4-prong M12 plug connector, angled version ST12-4-A

4-prong M12 plug connector, straight version ST12-4-G

4-prong M12 plug connector, straight version with 2 m cable ST12-4-GK

4-prong M12 plug connector, angled version with 2 m cable ST12-4-AK

G1/2, cylindrical G12-100

G1/2, cylindrical G12-250

R1/2, conical R12-100

R1/2, conical R12-250

N1/2, conical NPT N12-100

N1/2, conical NPT N12-250

Wall mounting kit AST1

100 mm immersion depth P2-TVS12-400100

250 mm immersion depth P2-TVS12-400250

Page 529: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-4

Standard Thermostats

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Standard Thermostats

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.

Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.

Single-stage frost protection thermostat (FT69)

Housing material Polycarbonate and ABS

Ambient temperature -20 ... 55 oC

Switch function/capacity SPDT 24..250 Vac, 15(8)A

Thermostat application frost protection thermostat

Protection class IP65

Capillary tube length Mechanical lock/reset Typem

1,8 manual FT6960-18F3 manual FT6960-30F6 manual FT6960-60F

1,8 automatic FT6961-18F3 automatic FT6961-30F6 automatic FT6961-60F

Capillary tube length Mechanical lock/reset Typem

1,8 manual FT6960-183 manual FT6960-306 manual FT6960-60

1,8 automatic FT6961-183 automatic FT6961-306 automatic FT6961-60

Room thermostat, industrial, 1/2 stages (T6120)

Housing material glass fibre reinforced ABS

Setpoint device knob

Thermostat application room thermostat

Differential fixed 1 K

Additional description T6120B is dual stage, with 2..10 K difference between the stages.

Temp. setpoint range Switch function/capacity Protection class TypeoC

0 ... 60 SPDT 250Vac 10A (1,5A) IP54 T6120A1005-30 ... 30 SPDT 250Vac 15A (8A) IP65 T6120B1003

Page 530: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-5

Standard Thermostats

16

17

18

19

20

21

22

24

23

25

26

27

28

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.

Fixed switching difference

Adjustable switching difference

Accessories

Room thermostat for industrial permises (TRM)

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material die cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 70 oC

Switch function/capacity SPDT 250 Vac, 8(5) A

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -351: protection class IP65 and switching housing with surface

protection (chemical version)• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc,

100 mA, min. 5 Vdc, 2 mA, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Thermostat application room thermostat, industrial

Additional description Including mounting bracket typenumber H1.

Temp. setpoint range Differential fixed Differential setting range Max. perm. temp. at sensor TypeoC K K oC

-20 ... 20 1 – 70 TRM0220 ... 40 1 – 70 TRM40

10 ... 50 1 – 70 TRM150

Temp. setpoint range Differential fixed Differential setting range Max. perm. temp. at sensor TypeoC K K oC

0 ... 40 – 3 ... 10 70 TRMV4010 ... 50 – 3 ... 10 70 TRMV150

Cover for outdoor application S1

Sealing P2

Heat conducting compound WLP1

Page 531: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-6

Standard Thermostats

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes.

Immersion wells

Immersion tubes NPT

More Accessories

Capillary tube thermostat with sensing bulb (TAM)

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material die-cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 70 oC

Switch function/capacity SPDT 250 Vac, 8(5) A

Capillary tube length 1,5 m

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -351: protection class IP65 and switching housing with surface

protection (chemical version)• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc,

100 mA, min. 5 Vdc, 2 mA, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Thermostat application capillary tube thermostat

Temp. setpoint range Differential fixed Max. perm. temp. at sensor TypeoC K oC

-20 ... 20 1,5 110 TAM02210 ... 50 1,5 110 TAM15040 ... 90 2 125 TAM490

80 ... 130 2 150 TAM813

Red brass well G1/2" PN25, immersion/total length 135/151 mm R1/MS

Stainless steel well G1/2" PN63, immersion/total length 135/151 mm R1/Nst

Red brass well G1/2" PN25, immersion/total length 220/236 mm R2/MS

Stainless steel well G1/2" PN63, immersion/total length 220/236 mm R2/Nst

Red brass well G1/2" PN25, immersion/total length 500/516 mm R3/MS

Capillary tube bushing with 3 mm capillary tube screw in thread G1/2, not pressure-tight

R4

Capillary tube bushing, rubber plug for 3 mm capillary tube, bore diameter 10 mm, not pressure-tight

R5

Red brass well G1/2" NPT PN25, immersion/total length 135/151 mm RN1/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 135/151 mm RN1/NST

Red brass well G1/2" NPT PN25, immersion/total length 220/236 mm RN2/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 220/236 mm RN2/NST

Sealing P2

Heat conducting compound WLP1

Page 532: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-7

Standard Thermostats

16

17

18

19

20

21

22

24

23

25

26

27

28

Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application.

Immersion length 135 mm

Immersion length 220 mm

Accessories

Immersion wells

Immersion wells NPT

Immersion pipes for airducts

Rod thermostat for vessels (TX)

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material die cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 70 oC

Switch function/capacity SPDT 250 Vac, 8(5) A

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP 65• -351: protection class IP65 and switching housing with surface

protection (chemical version)• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc,

100 mA, min. 5 Vdc, 2 mA, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Thermostat application immersion rod thermostat

Temp. setpoint range (oC) Immersion depth (mm) Differential fixed (K) Max. perm. temp. at sensor (oC) Type-20 ... 30 135 1,5 110 TX02310 ... 50 135 1,5 110 TX15040 ... 90 135 2,5 125 TX490

80 ... 130 135 4 150 TX813

Temp. setpoint range (oC) Immersion depth (mm) Differential fixed (K) Max. perm. temp. at sensor (oC) Type-20 ... 30 220 1,5 110 TXB02310 ... 50 220 1,5 110 TXB15040 ... 90 220 2,5 125 TXB490

80 ... 130 220 4 150 TXB813

Cover for outdoor application S1

Sealing P2

Heat conducting compound WLP1

Red brass well G1/2" PN25, immersion/total length 135/151 mm R10/MS

Red brass well G1/2" PN25, immersion/total length 220/236 mm R20/MS

Stainless steel well G1/2" PN63, immersion/total length 135/151 mm R10/NST

Stainless steel well G1/2" PN63, immersion/total length 220/236 mm R20/NST

Red brass well 1/2"NPT PN25, immersion/total length 135/151 mm RN10/MS

Red brass well 1/2"NPT PN25, immersion/total length 220/236 mm RN20/MS

Stainless steel well 1/2"NPT PN63, immersion/total length 135/151 mm RN10/NST

Stainless steel well 1/2"NPT PN63, immersion/total length 220/236 mm RN20/NST

Immersion pipe, chrome plated steel, immersion/total length 25/40 mm R6

Immersion pipe, chrome plated steel, immersion/total length 117/132 mm R7

Page 533: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-8

Thermostats, component-tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Thermostats, component-tested

Sealing pipe thermostat with well.

Accessories

The STB Servies of universal strap-on thermostats are designed for floor heating applications. They are suitable for use as strap-on, wall-mounted, or (with optional immersion well) immersion thermostat.Devices of the STB Series likewise measure temperature. If the sensor temperature exceeds the set value, a snap-action switch opens, interrupting the electrical circuit, and remains open until reset manually. (Also, if the sensor temperatuire drops to below approx. - 20 degrees C, the snap-action switch opens, but closes again automatically after the temperature rises again.) To manually reset the device, the sensor temperature must drop by more than approx. 10 K.

Safety limiting thermostat, with hand reset (STB1)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity SPST 230 Vac, 10 A

Mechanical lock/reset mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval STB 89 507

Thermostat application immersion tube thermostat

Thermostat functions temp. setting inside, reset outside

Temp. setpoint range 60 ... 130 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

150 oC

TypeSTB1F

Steel well R1/2" x 150 mm T4NST

Steel well R1/2" x 150 mm T4NSTF

Safety strap-on thermostat (temperature limiter) for floor heating applications (STB)

Electrical connection M20x1,5

Protection class IP54

Housing material PA, ABS, PMMA

Ambient temperature 0 ... 80 oC

Switch function/capacity max: 230Vac, 12 (2,5) A / min: 24 Vac/dc, 100 mA

Mechanical lock/reset manual reset

Setpoint device knob

Certificates CE, UL, PED, DIN EN 14597

Thermostat application strap-on thermostat

Differential fixed 10 K

Temp. setpoint range TypeoC

20 ... 80 STB208070 ... 130 STB70130

Page 534: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-9

Thermostats, component-tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Accessories

Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Temp. setpoint range TypeoC

20 ... 80 STB2080F70 ... 130 STB70130F

Immersion Well, G1/2 STG12-100

Safety limiting thermostat with setpoint knob, shut-off (STBTR)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval TR / STB 90 007

Thermostat application immersion tube therm. + controller

Thermostat functions temp. setting inside + outside, reset outside

Temp. setpoint range 30 ... 110 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

130 oC

Additional description Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.

TypeSTB+TRF

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 535: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-10

Thermostats, component-tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Safety limiting thermostat, with shut-off (STBTW)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, with hand reset on outside of thermostat

Immersion depth 150 mm

Certificates TUEV-approval TW / STB 90 407

Thermostat application immersion tube therm. + monitor

Thermostat functions temp. setting inside, reset outside

Temp. setpoint range 30 ... 110 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

130 oC

Additional description Safety control switching differential approx. 3..4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.

TypeSTB+TWF

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 536: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-11

Thermostats, component-tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Sealing pipe thermostat with well.

Accessories

Safety limiting thermostat, hand reset, large range (STW1)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity SPDT 230 Vac, 10 A

Mechanical lock/reset no mechanical lock

Certificates TUEV-approval STW (STB)89 407 S

Thermostat application immersion tube thermostat

Thermostat functions temp. setting inside, reset inside

Temp. setpoint range 20 ... 150 oC

Mounting place in pipe

Immersion depth 150 mm

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

175 oC

Additional description Fixed switching differential approx. 4% of setpoint value.

TypeSTW1F

Steel well R1/2" x 150 mm T4NST

Steel well R1/2" x 150 mm T4NSTF

Page 537: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-12

Thermostats, component-tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The STW Servies of universal strap-on thermostats are designed for floor heating applications. They are suitable for use as strap-on, wall-mounted, or (with optional immersion well) immersion thermostat.Devices of the STW Series measure temperature. If the sensor temperature exceeds the set value, a snap-action switch opens, interrupting the electrical circuit. As soon as the sensor temperature drops by more than 10 K, the snap-action switch again closes automatically. (Also, if the sensor temperature drops to below approx. 20 degrees C, the snap-action switch opens, but closes again automatically after the temperature rises again.

Accessories

Accessories

Safety strap-on thermostat for floor heating applications (STW)

Electrical connection M20x1,5

Protection class IP54

Housing material PA, ABS, PMMA

Ambient temperature 0 ... 80 oC

Switch function/capacity max: 230Vac, 12 (2,5) A min: 24 Vad/dc, 100 mA

Mechanical lock/reset automatic reset

Setpoint device knob

Certificates CE, UL, PED, DIN EN 14597

Thermostat application strap-on thermostat

Differential fixed 10 K

Temp. setpoint range TypeoC

20 ... 80 STW208070 ... 130 STW70130

Temp. setpoint range TypeoC

20 ... 80 STW2080F70 ... 130 STW70130F

Immerson well, G1/2, 100 mm STG12-100

Immerson well, G1/2, 100 mm STG12-100F

Page 538: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-13

Thermostats, component-tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Sealing pipe thermostat with well.For safety temperature control, and in addition high temperature shut-off functionality.

Accessories

Safety limiting thermostat with setpoint knob, shut-off, automatic reset (STWTR)

Protection class IP54

Housing material Aluminium diecasting with plastic cover

Ambient temperature 0 ... 80 oC

Switch function/capacity safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A

Mechanical lock/reset shut-off mechanical lock, automatic reset

Immersion depth 150 mm

Certificates TUEV-approval TR / STW (STB)89 907 S

Thermostat application immersion tube therm. + controller

Thermostat functions temp. setting inside + outside, reset inside

Temp. setpoint range 20 ... 150 oC

Mounting place in pipe

Immersion well material red brass, nickel plated

Immersion well thread R1/2"

Max. perm. temp. at sensor

175 oC

Additional description Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 20..150 oC adjustable.

TypeSTW+TRF

Steel well R1/2" x 150 mm T5NST

Steel well R1/2" x 150 mm T5NSTF

Page 539: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-14

Thermostats with ATEX approval

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Thermostats with ATEX approval

Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses, also for monitoring the maximum temperature in switchgear cabinets and relay stations.Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db

Accessories

Room thermostat (Ex) for industrial permises (Ex-TRM)

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material die cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 60 oC

Switch function/capacity SPDT 250 Vac, 3(2) A

Certificates • SIL 2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Thermostat application room thermostat

Differential fixed 1 K

Max. perm. temp. at sensor

70 oC

Additional description Including mounting bracket typenumber H1.

Temp. setpoint range TypeoC

-20 ... 20 EX-TRM0220 ... 40 EX-TRM40

10 ... 50 EX-TRM150

Cover for outdoor application S1

Sealing P2

Heat conducting compound WLP1

Page 540: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-15

Thermostats with ATEX approval

16

17

18

19

20

21

22

24

23

25

26

27

28

The sensor cartridge at the end of the capillary tube is the actual active (temperature sensitive) part of the sensor. Changes in temperature on the capillary tube have no effect on the switching point. Pressuretight installation of the sensor in pressure vessels of all kinds is possible with the aid of immersion tubes. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db

Immersion wells

Immersion tubes NPT

More Accessories

Capillary tube thermostat (Ex) with sensing bulb (Ex-TAM)

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material die-cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 60 oC

Switch function/capacity SPDT 250 Vac, 3(2) A

Capillary tube length 1,5 m

Certificates • SIL 2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Thermostat application capillary tube thermostat

Temp. setpoint range Differential fixed Max. perm. temp. at sensor TypeoC K oC

-20 ... 20 1,5 110 EX-TAM02210 ... 50 1,5 110 EX-TAM15040 ... 90 2 125 EX-TAM490

80 ... 130 2 150 EX-TAM813

Red brass well G1/2" PN25, immersion/total length 135/151 mm R1/MS

Stainless steel well G1/2" PN63, immersion/total length 135/151 mm R1/NST

Red brass well G1/2" PN25, immersion/total length 220/236 mm R2/MS

Stainless steel well G1/2" PN63, immersion/total length 220/236 mm R2/NST

Red brass well G1/2" PN25, immersion/total length 500/516 mm R3/MS

Capillary tube bushing with 3 mm capillary tube screw in thread G1/2, not pressure-tight

R4

Capillary tube bushing, rubber plug for 3 mm capillary tube, bore diameter 10 mm, not pressure-tight

R5

Red brass well G1/2" NPT PN25, immersion/total length 135/151 mm RN1/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 135/151 mm RN1/NST

Red brass well G1/2" NPT PN25, immersion/total length 220/236 mm RN2/MS

Stainless steel well G1/2" NPT PN63, immersion/total length 220/236 mm RN2/NST

Sealing P2

Heat conducting compound WLP1

Page 541: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

23-16

Thermostats with ATEX approval

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The suitable immersion tube has to be chosen according to the application. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 2D Ex tb IIIC T80 oC Db

Immersion length 135 mm

Immersion length 220 mm

Accessories

Immersion wells

Immersion wells NPT

Immersion pipes for airducts

Rod thermostat (Ex) for vessels (Ex-TX)

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material die cast metal GD Al Si 12 to DIN 1725

Ambient temperature -15 ... 60 oC

Switch function/capacity SPDT 250 Vac, 3(2) A

Certificates • SIL 2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Thermostat application immersion rod thermostat

Temp. setpoint range Immersion depth Differential fixed Max. perm. temp. at sensor TypeoC mm K oC

-20 ... 30 135 1,5 110 EX-TX02310 ... 50 135 1,5 110 EX-TX15040 ... 90 135 2,5 125 EX-TX490

Temp. setpoint range Immersion depth Differential fixed Max. perm. temp. at sensor TypeoC mm K oC

-20 ... 30 220 1,5 110 EX-TXB02310 ... 50 220 1,5 110 EX-TXB15040 ... 90 220 2,5 125 EX-TXB490

Cover for outdoor application S1

Sealing P2

Heat conducting compound WLP1

Red brass well G1/2" PN25, immersion/total length 135/151 mm R10/MS

Red brass well G1/2" PN25, immersion/total length 220/236 mm R20/MS

Stainless steel well G1/2" PN63, immersion/total length 135/151 mm R10/NST

Stainless steel well G1/2" PN63, immersion/total length 220/236 mm R20/NST

Red brass well 1/2"NPT PN25, immersion/total length 135/151 mm RN10/MS

Red brass well 1/2"NPT PN25, immersion/total length 220/236 mm RN20/MS

Stainless steel well 1/2"NPT PN63, immersion/total length 135/151 mm RN10/NST

Stainless steel well 1/2"NPT PN63, immersion/total length 220/236 mm RN20/NST

Immersion pipe, chrome plated steel, immersion/total length 25/40 mm R6

Immersion pipe, chrome plated steel, immersion/total length 117/132 mm R7

Page 542: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure switches Page

Electronic Pressure Switches 24-2Standard Pressure Switches 24-8Pressure Switches, component tested 24-15Pressure Switches with ATEX Approval 24-25Pressure Switches, component-tested with ATEX Approval 24-30Accessories 24-32

Page 543: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-2

Electronic Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Electronic Pressure Switches

Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.Models available with the following output types:

• all models: switch output open collector; 14..36 Vdc, 250 mA• PST -series: transmitter output; 0..10 Vdc or 4..20 mA• PST..R -series: relay output with gold plated SPDT contact

Switch + Transmitter, PST ...-models

Electronic Pressure switch for liquid, high viscosity/roiled liquid (SmartPress)

Protection class IP65

Housing material Polybutylene terephtalate (PBT)

Sensing element material 1.4571 + 1.4435

Media temp. -20 ... 100 oC

Media temp. limit Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)

Ambient temperature -20 ... 60 oC

Switch function/capacity PST-models: Open collector switch max. 250 mA dc at 14 ... 36 Vdc. PST..R-models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.

Additional description • Applicable parameter settings:• switching Set / Reset points• filters• analog output range• electrical drag indicator• Applicable configurations:• Max-Min, Window monitor• Analog output signal• Pressure unit• Simulation mode• Plugs have to be ordered separately !

Pressure range Max. pressure Kind of pressure Typebar bar

-1 ... 1 6 vacuum, relative PSTV01RG34F0 ... 0,25 1 overpressure, relative PSTM250RG34F0 ... 0,4 2 overpressure, relative PSTM400RG34F0 ... 0,6 2 overpressure, relative PSTM600RG34F

0 ... 1 6 overpressure, relative PST001RG34F0 ... 1,6 6 overpressure, relative PST002RG34F

0 ... 4 12 overpressure, relative PST004RG34F0 ... 10 30 overpressure, relative PST010RG34F0 ... 25 75 overpressure, relative PST025RG34F0 ... 2 6 absolute PST002AG34F

0 ... 10 30 absolute PST010AG34F

Page 544: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-3

Electronic Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

Switch + Transmitter + Relay output, PST..R -models

Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons

Pressure range Max. pressure Kind of pressure Typebar bar

-1 ... 1 6 vacuum, relative PSTV01RG34F-R0 ... 0,25 1 overpressure, relative PSTM250RG34F-R0 ... 0,4 2 overpressure, relative PSTM400RG34F-R0 ... 0,6 2 overpressure, relative PSTM600RG34F-R

0 ... 1 6 overpressure, relative PST001RG34F-R0 ... 1,6 6 overpressure, relative PST002RG34F-R

0 ... 4 12 overpressure, relative PST004RG34F-R0 ... 10 30 overpressure, relative PST010RG34F-R0 ... 25 75 overpressure, relative PST025RG34F-R0 ... 2 6 absolute PST002AG34F-R

0 ... 10 30 absolute PST010AG34F-R

5-prong M12 plug connector, angled version ST12-5-A

5-prong M12 plug connector, straight version ST12-5-G

4-prong M12 plug connector, angled version ST12-4-A

4-prong M12 plug connector, straight version ST12-4-G

4-prong M12 plug connector, straight version with 2 m cable ST12-4-GK

4-prong M12 plug connector, angled version with 2 m cable ST12-4-AK

Plug protection cap, IP65 STA12

Syphons for high temperature, steel, U-shape. For more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 545: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-4

Electronic Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.Models available with the following output types:

• all models: switch output open collector; 14..36 Vdc, 250 mA• PST -series: transmitter output; 0..10 Vdc or 4..20 mA• PST..R -series: relay output with gold plated SPDT contact

Switch + Transmitter output, PST-models

Electronic Pressure switch for gas, low viscosity liquid (SmartPress)

Protection class IP65

Housing material Polybutylene terephtalate (PBT)

Media temp. -20 ... 100 oC

Media temp. limit Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)

Ambient temperature -20 ... 60 oC

Switch function/capacity PST..R-models with relay contact output, 1 x SPDT, material silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA. With bigger loads, the gold layer will disappear, the capacity with the silver contacts is: 230 Vac 3(1) A.

Sensing element material 1.4571 + 1.4542

Additional description Applicable parameter settings:• switching Set / Reset points• filters• analog output range• electrical drag indicator• Applicable configurations:• Max-Min, Window monitor• Analog output-signal• Pressure unit• Simulation mode• Plugs have to be ordered separately !

Pressure range Max. pressure Output signal Kind of pressure Typebar bar

-1 ... 1 6 0..10Vdc / 4..20 mA + switch vacuum, relative PSTV01RG12S0 ... 0,25 1 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM250RG12S

0 ... 0,4 2 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM400RG12S0 ... 0,6 2 0..10Vdc / 4..20 mA + switch overpressure, relative PSTM600RG12S

0 ... 1 6 0..10Vdc / 4..20 mA + switch overpressure, relative PST001RG12S0 ... 1,6 6 0..10Vdc / 4..20 mA + switch overpressure, relative PST002RG12S

0 ... 4 12 0..10Vdc / 4..20 mA + switch overpressure, relative PST004RG12S0 ... 10 30 0..10Vdc / 4..20 mA + switch overpressure, relative PST010RG12S0 ... 25 75 0..10Vdc / 4..20 mA + switch overpressure, relative PST025RG12S0 ... 60 180 0..10Vdc / 4..20 mA + switch overpressure, relative PST060RG12S

0 ... 100 300 0..10Vdc / 4..20 mA + switch overpressure, relative PST100RG12S0 ... 250 500 0..10Vdc / 4..20 mA + switch overpressure, relative PST250RG12S0 ... 600 1000 0..10Vdc / 4..20 mA + switch overpressure, relative PST600RG12S

0 ... 2 6 0..10Vdc / 4..20 mA + switch absolute PST002AG12S0 ... 10 30 0..10Vdc / 4..20 mA + switch absolute PST010AG12S

Page 546: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-5

Electronic Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

Switch + Transmitter + Relay output, PST..R -models

Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons

Pressure range Max. pressure Output signal Kind of pressure Typebar bar

-1 ... 1 6 0..10Vdc / 4..20 mA + switch + relay vacuum, relative PSTV01RG12S-R0 ... 0,25 1 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM250RG12S-R

0 ... 0,4 2 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM400RG12S-R0 ... 0,6 2 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PSTM600RG12S-R

0 ... 1 6 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST001RG12S-R0 ... 1,6 6 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST002RG12S-R

0 ... 4 12 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST004RG12S-R0 ... 10 30 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST010RG12S-R0 ... 25 75 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST025RG12S-R0 ... 60 180 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST060RG12S-R

0 ... 100 300 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST100RG12S-R0 ... 250 500 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST250RG12S-R0 ... 600 1000 0..10Vdc / 4..20 mA + switch + relay overpressure, relative PST600RG12S-R

0 ... 2 6 0..10Vdc / 4..20 mA + switch + relay absolute PST002AG12S-R0 ... 10 30 0..10Vdc / 4..20 mA + switch + relay absolute PST010AG12S-R

5-prong M12 plug connector, angled version ST12-5-A

5-prong M12 plug connector, straight version ST12-5-G

4-prong M12 plug connector, angle version ST12-4-A

4-prong M12 plug connector, straight version ST12-4-G

4-prong M12 plug connector, straight version with 2 m cable ST12-4-GK

4-prong M12 plug connector, angled version with 2 m cable ST12-4-AK

Plug protection cap, IP65 STA12

Syphons for high temperature, steel, U-shape. for more accessories, see Accessories for Pressure Switches / Transmitters

U430B

Page 547: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-6

Electronic Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Electronic Pressure Switches are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring, and control of system pressure.Features:

• Open-collector• Configurable as min./max/window monitor• Adjustable drop-in/drop-out delay• Hysteresis defined by set-point and reset-point• Baclit LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software

Pressure Switch HMI

Accessory

Electronic Pressure switch for gas and liquid (Smart DCM)

Media temp. -20 ... 80 oC

Sensing element material 1.4571

Protection class IP65

Ambient temperature -20 ... 70 oC

Pressure range (bar) Max. pressure (bar) Type-1 ... 1 6 PSHRV10110 ... 1 3 PSHRB00110 ... 4 12 PSHRB0041

0 ... 10 30 PSHRB01010 ... 16 48 PSHRB01610 ... 25 50 PSHRB02510 ... 40 80 PSHRB0401

Field configuration tool CFT1

Page 548: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-7

Electronic Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

Electronic Differential Pressure Switches are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording, monitoring and control of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.Features:

• Open-collector• Configurable as min./max./window monitor• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o

• Self-monitoring electronics• Adjustable drop-in/drop-out delay

Pressure Swith HMI

Electronic Differential Pressure Switches for gas and liquid (Smart DCM DIFF)

Media temp. -20 ... 80 oC

Protection class IP65

Ambient temperature -20 ... 70 oC

Pressure range (bar) Max. pressure (bar) Type0 ... 0,1 0,9 PSHDM10020 ... 0,3 0,9 PSHDM3002

0 ... 1 3 PSHDB00120 ... 3 9 PSHDB00320 ... 6 21 PSHDB0062

0 ... 20 60 PSHDB0202

Page 549: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-8

Standard Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Standard Pressure Switches

For overpressure monitoring of non-aggressive liquids and gaseous media.

Fixed pressure hysteresis

Pressure switch for liquid, gas (DCM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65• -217: two microswitches, 1 plug, switching in succession,

adjustable switching interval• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL 2 according IEC 61508-2

Pressure adjustmentrange (bar)

Adjustable switchingdifferential (bar)

Switchingdifferential (bar)

Max.pressure (bar)

Sensing elementmaterial

Type

0,04 ... 0,25 – 0,03 6 Copper + Brass DCM0250,1 ... 0,6 – 0,04 6 Copper + Brass DCM060,2 ... 1,6 – 0,04 6 Copper + Brass DCM10,2 ... 2,5 – 0,1 16 1.4104 + 1.4571 DCM3

0,5 ... 6 – 0,15 16 1.4104 + 1.4571 DCM60,5 ... 6 – 0,25 25 1.4104 + 1.4571 DCM6251 ... 10 – 0,3 25 1.4104 + 1.4571 DCM103 ... 16 – 0,5 25 1.4104 + 1.4571 DCM164 ... 25 – 1 60 1.4104 + 1.4571 DCM258 ... 40 – 1,3 60 1.4104 + 1.4571 DCM40

16 ... 63 – 2 130 1.4104 + 1.4571 DCM630,04 ... 0,25 – 0,03 6 1.4104 + 1.4571 DNM025

Page 550: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-9

Standard Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

Adjustable pressure hysteresis

For overpressure monitoring of non-aggressive liquids and gaseous media.

Fixed pressure hysteresis

Pressure adjustmentrange (bar)

Adjustable switchingdifferential (bar)

Switchingdifferential (bar)

Max.pressure (bar)

Sensing elementmaterial

Type

0,04 ... 0,25 0,03 ... 0,4 – 6 Copper + Brass DCMV0250,1 ... 0,6 0,04 ... 0,5 – 6 Copper + Brass DCMV060,2 ... 1,6 0,07 ... 0,55 – 6 Copper + Brass DCMV10,2 ... 2,5 0,15 ... 1,5 – 16 1.4104 + 1.4571 DCMV3

0,5 ... 6 0,25 ... 2 – 16 1.4104 + 1.4571 DCMV61 ... 10 0,5 ... 2,8 – 25 1.4104 + 1.4571 DCMV103 ... 16 0,7 ... 3,5 – 25 1.4104 + 1.4571 DCMV164 ... 25 1,3 ... 6 – 60 1.4104 + 1.4571 DCMV258 ... 40 2,6 ... 6,6 – 60 1.4104 + 1.4571 DCMV40

16 ... 63 3 ... 10 – 130 1.4104 + 1.4571 DCMV63

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Pressure switch for liquid, gas, small range (DCM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Pressure adjustment range (mbar) Switching differential (mbar) Max. pressure (bar) Sensing element material Type1 ... 16 2 1 Perbunan + 1.4301 DCM40164 ... 25 2 1 Perbunan + 1.4301 DCM4025

10 ... 100 12 10 Perbunan + Brass DCM100015 ... 60 10 12 1.4104 + 1.4571 DCM506

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 551: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-10

Standard Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.

Pressure switch for aggressive liquid, gas (DNS)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65• -217: two microswitches, 1 plug, switching in succession,

adjustable switching interval• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Sensing element material 1.4571

Page 552: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-11

Standard Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

Fixed pressure hysteresis

Adjustable pressure hysteresis

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar bar bar bar

0,04 ... 0,25 – 0,03 6 DNS025-2010,1 ... 0,6 – 0,04 6 DNS06-2010,2 ... 1,6 – 0,06 6 DNS1-2010,2 ... 2,5 – 0,1 16 DNS3-201

0,5 ... 6 – 0,15 16 DNS6-2011 ... 10 – 0,3 16 DNS10-2013 ... 16 – 0,5 25 DNS16-201

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar bar bar bar

0,04 ... 0,25 0,06 ... 0,3 – 6 DNS025-2030,1 ... 0,6 0,08 ... 0,4 – 6 DNS06-2030,2 ... 1,6 0,1 ... 0,6 – 6 DNS1-2030,2 ... 2,5 0,15 ... 1,5 – 16 DNS3-203

0,5 ... 6 0,25 ... 2 – 16 DNS6-2031 ... 10 0,45 ... 2,5 – 16 DNS10-2033 ... 16 0,8 ... 3,5 – 25 DNS16-203

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 553: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-12

Standard Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.

Differential pressure switch for liquid, gas (DDCM)

Kind of pressure differential pressure, relative

Pressure connection internal thread G1/4

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -205: maximum limiter with reclosing lock-out, interlocking with

increasing pressure• -206: Minimum limiter with reclosing lock-out, interlocking with

falling pressure• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65 (with the exception of DDCM252, 662, 1602, 6002)

• -217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252, 662, 1602, 6002)

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Pressure adjustment range Switching differential Max. pressure Sensing element material Typebar bar bar

0,004 ... 0,025 0,002 0,5 Perbunan + Aluminium DDCM2520,01 ... 0,06 0,015 1,5 Perbunan + Aluminium DDCM6620,02 ... 0,16 0,02 3 Perbunan + Aluminium DDCM1602

0,1 ... 0,6 0,035 3 Perbunan + Aluminium DDCM6002-0,1 ... 0,4 0,15 15 1.4305 + 1.4571 DDCM0140,2 ... 1,6 0,13 15 1.4305 + 1.4571 DDCM1

1 ... 4 0,2 25 1.4305 + 1.4571 DDCM40,5 ... 6 0,2 15 1.4305 + 1.4571 DDCM63 ... 16 0,6 25 1.4305 + 1.4571 DDCM16

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 554: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-13

Standard Pressure Switches

16

17

18

19

20

21

22

24

23

25

26

27

28

For monitoring vacuum of non-aggressive liquids and gaseous media.

Fixed pressure hysteresis

Adjustable pressure hysteresis

Vacuum switch for liquid, gas (VCM)

Kind of pressure vacuum, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case (with the exception of VCM4156), IP65

• -217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of VCM4156)

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Pressure adjustmentrange

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Sensing elementmaterial

Type

bar bar mbar bar

-0,015 ... 0,006 – 2 1 Perbunan + 1.4301 VCM4156-0,25 ... 0,1 – 25 1,5 Copper + Brass VCM301-0,25 ... 0,1 – 45 3 1.4104 + 1.4571 VNM301

-1 ... 0,1 – 45 3 Copper + Brass VCM101-0,9 ... 0,5 – 50 3 Copper + Brass VCM095

-1 ... 0,1 – 50 6 1.4104 + 1.4571 VNM111

Pressure adjustmentrange

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Sensing elementmaterial

Type

bar bar mbar bar

-0,25 ... 0,1 0,03 ... 0,2 – 1,5 Copper + Brass VCMV301-0,25 ... 0,1 0,07 ... 0,5 – 3 1.4104 + 1.4571 VNMV301

-1 ... 0,1 0,08 ... 0,35 – 3 Copper + Brass VCMV101-0,9 ... 0,5 0,09 ... 0,4 – 3 Copper + Brass VCMV095

-1 ... 0,1 0,09 ... 0,65 – 6 1.4104 + 1.4571 VNMV111

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 555: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-14

Standard Pressure Switches

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For monitoring and controlling pressures in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored.

Fixed pressure hysteresis

Adjustable pressure hysteresis

Vacuum switch for aggressive liquid, gas (VNS)

Kind of pressure vacuum, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -301: terminal connection housing, IP65• -307: two microswitches, switching in parallel or in succession,

fixed switching interval, terminal connection case, IP65• -217: two microswitches, 1 plug, switching in succession,

adjustable switching interval• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100

mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -351: protection class IP65 and switching housing with surface protection (chemical version)

• -513: gold-plated contacts, switching differential permanent, IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

Certificates SIL2 according IEC 61508-2

Sensing element material 1.4571

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar mbar mbar bar

-0,25 ... 0,1 – 45 3 VNS301-201-1 ... 0,1 – 50 6 VNS111-201

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar mbar mbar bar

-0,25 ... 0,1 70 ... 300 – 3 VNS301-203-1 ... 0,1 90 ... 550 – 6 VNS111-203

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 556: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-15

Pressure Switches, component tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure Switches, component tested

For overpressure monitoring of fuel gases.

Fixed pressure hysteresis

Pressure monitor for fuel gases (DGM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -25 ... 60 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -513: Gold-plated contacts, single-pole switch-over. Switching

differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA; suitable isolating switching amplifier, degree of protection Ex-ia

• -574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

Certificates • NG-4346 AP 1011 according DIN EN 1854• CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN

EN 1854 (01.07.2006)• SIL2 according IEC 61508-2

Pressure adjustment range Switching differential Max. pressure Sensing element material Typebar mbar bar

0,015 ... 0,06 6 0,8 Copper + Brass DGM306A0,02 ... 0,1 7 0,8 Copper + Brass DGM310A

0,04 ... 0,25 10 0,8 Copper + Brass DGM325A0,1 ... 0,6 25 2 Copper + Brass DGM06A0,2 ... 1,6 40 3 Copper + Brass DGM1A

0,015 ... 0,06 8 5 1.4104 + 1.4571 DGM5060,04 ... 0,16 12 5 1.4104 + 1.4571 DGM516

0,1 ... 0,25 20 5 1.4104 + 1.4571 DGM525

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 557: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-16

Pressure Switches, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Maximum pressure monitor with selfmonitoring sensorfor steam and hot water

Maximum pressure monitor of 'special construction' (DA)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -20 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -20 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -513: Gold-plated contacts, single-pole switch-over. Switching

differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier, degree of protection Ex-ia

• -576: (only DWAM) Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -577: (only DWAM) Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

Certificates • TUEV-DW-04-132 for DWAM ...according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007

• 01 202 931-B-11-0001 according Directive 97/23 EC• SIL2 according IEC 61508-2

Page 558: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-17

Pressure Switches, component tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Fixed pressure hysteresis

Adjustable pressure hysteresis

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar bar bar bar

0,1 ... 0,6 – 0,04 5 DWAM060,2 ... 1,6 – 0,05 5 DWAM1

1,2 ... 6 – 0,2 10 DWAM61,2 ... 6 – 0,25 20 DWAM6253 ... 16 – 0,4 20 DWAM166 ... 32 – 1,2 45 DWAM32

Pressure adjustment range Adjustable switching differential Switching differential Max. pressure Typebar bar bar bar

0,2 ... 1,6 0,12 ... 0,6 – 5 DWAMV11,2 ... 6 0,4 ... 1,5 – 10 DWAMV63 ... 16 0,8 ... 2,5 – 20 DWAMV163 ... 32 2,5 ... 6 – 45 DWAMV32

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 559: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-18

Pressure Switches, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.

Pressure monitor for hot water, steam, gas, fuel (DWR)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Mechanical lock/reset with special function possible

Optional functions add the type numbers below to the listed type numbers for extra functionality as described

• -213: gold-plated contacts, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.

• -301: terminal connection housing, IP65• -513: Gold-plated contacts, single-pole switch-over. Switching

differential permanent. IP65. Switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier, degree of protection Ex-ia

• -574: Normally closed contact with resistance combination for minimum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing with surface protection (chemical version), IP66, degree of protection Ex-ia

• -576: Normally closed contact with resistance combination for maximum pressure monitoring. Gold-plated contacts. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

• -577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring. Housing with surface protection (chemical version), IP65, degree of protection Ex-ia

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• CE-0085CL0343 according to DIN EN 1854, Issue 07.2006• 01 202 931-B-11-0003 according Directive 97/23 EC• SIL2 according IEC 61508-2

Page 560: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-19

Pressure Switches, component tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Fixed pressure hysteresis

Adjustable pressure hysteresis

Pressure adjustmentrange

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Allowable max.gas-pressure

Type

bar bar bar bar bar

0,1 ... 0,6 – 0,04 6 6 DWR060,2 ... 1,6 – 0,06 6 6 DWR10,2 ... 2,5 – 0,1 16 10 DWR3

0,5 ... 6 – 0,2 16 10 DWR60,5 ... 6 – 0,25 25 20 DWR6253 ... 16 – 0,5 25 20 DWR164 ... 25 – 1 63 50 DWR258 ... 40 – 1,3 63 50 DWR40

Pressure adjustmentrange

Adjustable switchingdifferential

Switchingdifferential

Max. pressure Allowable max.gas-pressure

Type

bar bar bar bar bar

0,1 ... 0,6 0,08 ... 0,5 – 6 6 DWR06-2030,2 ... 1,6 0,15 ... 0,6 – 6 6 DWR1-2030,2 ... 2,5 0,17 ... 1,2 – 16 10 DWR3-203

0,5 ... 6 0,3 ... 1,4 – 16 10 DWR6-2030,5 ... 6 0,4 ... 2,5 – 25 20 DWR625-2033 ... 16 0,75 ... 3,15 – 25 20 DWR16-2034 ... 25 1,3 ... 6 – 63 50 DWR25-2038 ... 40 2,3 ... 6,6 – 63 50 DWR40-203

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 561: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-20

Pressure Switches, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For maximum-pressure detection of steam, hot water, burnable gases, liquid fuels.

Maximum pressure limiter for hot water, steam, fuel, gas (DWR-B)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• TV-DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• ID 0000020756 according VdTUEV Memorandum Pressure 100, issue 04.83

• CE-0085CL0343 according DIN EN 1854, Issue 7.2006• 01 202 931-B-11-0003 according to Directive 97/23 EG• SIL2 according IEC 61508-2

Pressure interlock/Reset maximum press./button

Pressure adjustment range Max. pressure Allowable max. gas-pressure Typebar bar bar

0,1 ... 0,6 6 6 DWR06-2050,2 ... 1,6 6 6 DWR1-2050,2 ... 2,5 16 10 DWR3-205

0,5 ... 6 16 10 DWR6-2050,5 ... 6 25 20 DWR625-2053 ... 16 25 20 DWR16-2054 ... 25 63 50 DWR25-2058 ... 40 63 50 DWR40-205

Syphon for high temperature, steel, U-shape, for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 562: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-21

Pressure Switches, component tested

16

17

18

19

20

21

22

24

23

25

26

27

28

For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.

Minimum pressure limiter for hot water, steam, fuel, gas (DWR-B)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -25 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11:2007 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• ID 0000020757 according VdTUEV Memorandum Pressure 100, Issue 4.83

• CE-0085CL0343 according DIN EN 1854, Issue 7.2006• 01 202 931-B-11-0003 according to Directive 97/23 EG• SIL2 according IEC 61508-2

Pressure interlock/Reset minimum press./button

Pressure adjustment range Max. pressure Allowable max. gas-pressure Typebar bar bar

0,1 ... 0,6 6 6 DWR06-2060,2 ... 1,6 6 6 DWR1-2060,2 ... 2,5 16 10 DWR3-206

0,5 ... 6 16 10 DWR6-2060,5 ... 6 25 20 DWR625-2063 ... 16 25 20 DWR16-2064 ... 25 63 50 DWR25-2068 ... 40 63 50 DWR40-206

Syphon for high temperature, steel, U-shape, for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 563: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-22

Pressure Switches, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Maximum pressure limiter for liquid gas systems with safety function, degree of protection Ex-ia (only together with isolating switching amplifier).

For monitoring pressure of neutral and non-aggressive gases.

Maximum pressure limiter (FD)

Kind of pressure overpressure, relative

Pressure connection external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -25 ... 60 oC

Media temp. limit temperatures up to 60 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -25 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch with resistor combination for circuit- break and short-circuit

Certificates • ID 0000033127 according VdTUEV Memorandum Pressure 100/1, Issue 07.2006 and DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007

• 01 202 931-B-11-0002 according Directive 97/23/EC• SIL2 according IEC 61508-2

Pressure adjustment range 3 ... 16 bar

Max. pressure 40 bar

Sensing element material 1.4104 + 1.4571

Additional description Products only may be used in conjunction with isolating switching amplifier.

Switching differential Pressure interlock/Reset Typebar

0,5 maximum press./electrical FD16-3262,5 maximum press./button FD16-327

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Pressure switch for gas (HCD)

Kind of pressure differential pressure, relative

Pressure connection internal thread G1/4

Electrical connection PG13,5

Protection class IP40

Housing material aluminium die casting

Media temp. -15 ... 60 oC

Ambient temperature -15 ... 60 oC

Switch function/capacity SPDT Microswitch 240 Vac; capacity 2 A inductive, 10 A resistive

Certificates • E 3085/2 according gas appliance directive 90/396/EEC and pr EN 1854, issue 1995

Sensing element material Aluminium + Silicon

Page 564: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-23

Pressure Switches, component tested

16

17

18

19

20

21

22

24

23

25

26

27

28

Maximum pressure limiter with selfmonitoring sensor and internal relockFor steam and hot water.

Pressure adjustment range Max. pressure Typembar mbar

0,2 ... 3 100 HCD60031 ... 10 100 HCD60105 ... 50 200 HCD6050

15 ... 150 300 HCD6150

Maximum pressure limiter of 'special construction' (SDB)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection Plug DIN EN 175301

Protection class IP54

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Sensing element material 1.4104 + 1.4571

Media temp. -20 ... 70 oC

Media temp. limit temperatures up to 85 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -20 ... 70 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive

Certificates • TUEV-SDB-11-134 according VdTUEV Memorandum Pressure 100, Issue 07.2006, DIN EN 12952-11, Issue 09.2007 and DIN EN 12953-9, Issue 09.2007

• 01 202 931-B-11-0001 according to Directive 97/23/EC• SIL2 according IEC 61508

Pressure interlock/Reset maximum press./button

Pressure adjustment range Switching differential Max. pressure Typebar bar bar

0,2 ... 1,6 0,12 5 SDBAM10,4 ... 2,5 0,15 5 SDBAM2.5

1,2 ... 6 0,4 10 SDBAM61,2 ... 6 0,6 20 SDBAM6253 ... 16 0,8 20 SDBAM166 ... 32 3 45 SDBAM32

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 565: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-24

Pressure Switches, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.

Accessories

Differential pressure switch for air (DPS)

Kind of pressure overpressure, relative

Pressure connection plastic connection piece for 5 mm (internal) hose

Electrical connection AMP connector 6,3x0,8 (DIN 46244) or screw terminals

Protection class IP54

Sensing element material ABS + Silicon

Media temp. -20 ... 85 oC

Ambient temperature -20 ... 85 oC

Switch function/capacity SPDT switch 240 Vac; 1,5 A (0.4)A

Certificates CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854

Max. pressure 10 kPa

Additional description Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.

Pressure adjustment range Switching differential TypePa mbar

20 ... 200 0,1 DPS200F40 ... 400 0,2 DPS400F50 ... 500 0,2 DPS500F

200 ... 1000 1 DPS1000F500 ... 2500 1,5 DPS2500F

L-shaped bracket for installation turned by 90o, e.g. in the ceiling area DPSL

Page 566: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-25

Pressure Switches with ATEX Approval

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure Switches with ATEX Approval

Pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/DbFor overpressure monitoring of non-aggressive liquids and gaseous media.

Fixed pressure hysteresis

Pressure switch (Ex) for liquid, gas (Ex-DCM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch; capacity 2 A inductive, 3 A resistive

Certificates • SIL2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Pressure adjustment range Switching differential Max. pressure Sensing element material Typebar bar bar

0,001 ... 0,016 0,002 1 Perbunan + 1.4301 EX-DCM40160,004 ... 0,025 0,002 1 Perbunan + 1.4301 EX-DCM4025

1 ... 10 0,3 16 1.4104 + 1.4571 EX-DNM1016 ... 63 1 130 1.4104 + 1.4571 EX-DNM63

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 567: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-26

Pressure Switches with ATEX Approval

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db

Fixed pressure hysteresis

Pressure switch (Ex) for aggressive liquid, gas (Ex-DNS)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive

Certificates • IBExU12ATEX1040• SIL2 according IEC 61508-2

Sensing element material 1.4571

Pressure adjustment range Switching differential Max. pressure Typebar bar bar

0,04 ... 0,25 0,03 6 EX-DNS0250,1 ... 0,6 0,04 6 EX-DNS060,2 ... 1,6 0,06 6 EX-DNS10,2 ... 2,5 0,1 16 EX-DNS3

0,5 ... 6 0,15 16 EX-DNS61 ... 10 0,3 16 EX-DNS103 ... 16 0,5 25 EX-DNS16

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 568: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-27

Pressure Switches with ATEX Approval

16

17

18

19

20

21

22

24

23

25

26

27

28

Differential pressure switch for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/DbFor flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic checking of filter plant.

Differential pressure switch (Ex) for liquid, gas (Ex-DDCM)

Kind of pressure differential pressure, relative

Pressure connection internal thread G1/4

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch; capacity 2 A inductive, 3 A resistive

Certificates • SIL2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Pressure adjustment range Switching differential Max. pressure Sensing element material Typebar bar bar

0,004 ... 0,025 0,002 0,5 Perbunan + Aluminium EX-DDCM2520,01 ... 0,06 0,015 1,5 Perbunan + Aluminium EX-DDCM6620,02 ... 0,16 0,02 3 Perbunan + Aluminium EX-DDCM1602

0,1 ... 0,6 0,035 3 Perbunan + Aluminium EX-DDCM6002-0,1 ... 0,4 0,15 15 1.4305 + 1.4571 EX-DDCM0140,2 ... 1,6 0,13 15 1.4305 + 1.4571 EX-DDCM1

1 ... 4 0,2 25 1.4305 + 1.4571 EX-DDCM40,5 ... 6 0,2 15 1.4305 + 1.4571 EX-DDCM63 ... 16 0,6 25 1.4305 + 1.4571 EX-DDCM16

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 569: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-28

Pressure Switches with ATEX Approval

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Vacuum switches for Ex-applications. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/DbFor monitoring vacuum of non-aggressive liquids and gaseous media.

Vacuum switches (Ex) liquid, gas (Ex-VCM)

Kind of pressure vacuum, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive

Certificates • SIL2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Pressure adjustment range Switching differential Max. pressure Sensing element material Typembar mbar bar

-15 ... 6 2 1 Perbunan + 1.4301 EX-VCM4156-250 ... 100 25 1,5 Copper + Brass EX-VCM301-250 ... 100 45 3 1.4104 + 1.4571 EX-VNM301

-1000 ... 100 45 3 Copper + Brass EX-VCM101-900 ... 500 50 3 Copper + Brass EX-VCM095

-1000 ... 100 50 6 1.4104 + 1.4571 EX-VNM111

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 570: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-29

Pressure Switches with ATEX Approval

16

17

18

19

20

21

22

24

23

25

26

27

28

For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db

Fixed pressure hysteresis

Vacuum switch (Ex) for aggressive liquid, gas (Ex-VNS)

Kind of pressure vacuum, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12.

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive

Certificates • SIL2 according IEC 61508-2• IBExU12ATEX1040 according to ATEX 94/9/EC

Sensing element material 1.4571

Pressure adjustment range Switching differential Max. pressure Typembar mbar bar

-250 ... 100 45 3 EX-VNS301-1000 ... 100 50 6 EX-VNS111

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 571: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-30

Pressure Switches, component-tested with ATEX Approval

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Pressure Switches, component-tested with ATEX Approval

For overpressure monitoring in Ex-applications of fuel gases. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db

Pressure monitor (Ex) for burnable gas (Ex-DGM)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive

Certificates • NG-4346 AP 1011 according DIN EN 1854• CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and

DIN EN 1854 (01.07.2006)• IBExU12ATEX1040 according ATEX 94/9/EG• SIL2 according IEC 61508-2

Max. pressure 5 bar

Pressure adjustment range Switching differential Typembar mbar

15 ... 60 10 EX-DGM50640 ... 160 12 EX-DGM516

100 ... 250 20 EX-DGM525

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 572: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-31

Pressure Switches, component-tested with ATEX Approval

16

17

18

19

20

21

22

24

23

25

26

27

28

For overpressure monitoring in ex-applications of steam, hot water, burnable gases, liquid fuels. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb, Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db

Fixed pressure hysteresis

Pressure monitor (Ex) for hot water, steam, gas, fuel (Ex-DWR)

Kind of pressure overpressure, relative

Pressure connection internal thread G1/4, external thread G1/2

Electrical connection terminal connection M16x1,5

Protection class IP65

Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12

Sensing element material 1.4104 + 1.4571

Media temp. -15 ... 60 oC

Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters)

Ambient temperature -15 ... 60 oC

Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device

Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive

Certificates • ID 0000007042 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• TV.DWFS (SDBFS).12-281 according VdTUEV Memorandum Pressure 100, Issue 7.2006 and DIN EN 12952-11 and DIN EN 12953-9:2007

• ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2008

• CE-0085CL0343 according to DIN EN 1854, Issue 07.2006• 01 202 931-B-11-0003 according Directive 97/23 EC• IBExU12ATEX1040 according ATEX 94/9/EG• SIL2 according IEC 61508-02

Pressure adjustment range Switching differential Max. pressure Allowable max. gas-pressure Typebar bar bar bar

0,1 ... 0,6 0,04 6 6 EX-DWR060,2 ... 1,6 0,06 6 6 EX-DWR10,2 ... 2,5 0,1 16 10 EX-DWR3

0,5 ... 6 0,2 16 10 EX-DWR60,5 ... 6 0,25 25 20 EX-DWR6253 ... 16 0,5 25 20 EX-DWR164 ... 25 1 63 50 EX-DWR258 ... 40 1,3 63 50 EX-DWR40

Syphon for high temperature, steel, U-shape (for more accessories, see Accessories for Pressure Switches / Transmitters)

U430B

Page 573: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

24-32

Accessories

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Accessories

Flanged Pressure Mediators

Flanged Pressure Mediators, teflon surfaced

Flanged Pressure Mediators with 1 m pipeline

Flanged Pressure Mediators with 1 m pipeline, teflon surfaced

Pressure Mediator

Pressure Mediator, teflon surfaced

Screw-in Pressure Mediator

Syphons

Accessories

Accessories for Differential Switches / Transmitters

Accessories for Pressure Switches / Transmitters

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -40 ... 120 ZFV184-5080 0,15 -40 ... 120 ZFV184-80

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -40 ... 120 ZFV184-50PTFE80 0,15 -40 ... 120 ZFV184-80PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -30 ... 300 ZFV185-5080 0,15 -30 ... 300 ZFV185-80

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -30 ... 300 ZFV185-50PTFE80 0,15 -30 ... 300 ZFV185-80PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,4 -30 ... 120 ZFV162-50

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,4 -30 ... 120 ZFV162-50PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) TypeG1 0,5 -30 ... 120 ZFV749G1 0,5 -30 ... 120 ZFV749 - V191

Syphon for high temperature, steel, U-shape U430B

Syphon for high temperature, steinless steel, U-shape U480B

Syphon for high temperature, steel, circular K430D

Syphon for high temperature, stainless steel, circular K480D

Adapter NPT1

Pressure surge reducer DMW

Sealing P2

Shut-off valve combination, 3-venting valve VKD3

Shut-off valve combination, 5-venting valve VKD5

Male adapter union, O-ring NBR MAU8/MS

Male adapter union, O-ring FPM MAU8/NST

Page 574: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure transmitters Page

Electronic Pressure Transmitters 25-2Piezo-resistive transmitters 25-4Accessories 25-6

Page 575: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

25-2

Electronic Pressure Transmitters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Electronic Pressure Transmitters

Electronic Pressure Transmitters are microprocessor-controlled pressure measurement devices for relative pressures of -1 to +1 bar and 0 to 40 bar. They are suitable for an extremely wide range of applications, including the precision recordin and monitoring of system pressure.Features:

• Configurable as 0/2...10V or 0/4...20 mA (3-wire)• Adjustable attenuation filter• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software

Pressure Transmitter without HMI (2-wire, 4-20 mA)

Pressure Transmitter without HMI (3-wire, 0-10V)

Pressure Transmitter without HMI (3-wire, 4...20mA)

Pressure Transmitter with HMI (2-wire, 4-20 mA)

Electronic Pressure transmitter for gas and liquid (Smart SN)

Media temp. -20 ... 80 oC

Sensing element material 1.4571

Certificates All 2-wire versions are SIL2 approved according IEC 61508

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type-1 ... 1 6 IP67 -20 ... 80 PTSRV1011A20 ... 1 3 IP67 -20 ... 80 PTSRB0011A20 ... 4 12 IP67 -20 ... 80 PTSRB0041A2

0 ... 10 30 IP67 -20 ... 80 PTSRB0101A20 ... 16 48 IP67 -20 ... 80 PTSRB0161A20 ... 25 50 IP67 -20 ... 80 PTSRB0251A20 ... 40 80 IP67 -20 ... 80 PTSRB0401A2

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type-1 ... 1 6 IP67 -20 ... 80 PTSRV1011V30 ... 1 3 IP67 -20 ... 80 PTSRB0011V30 ... 4 12 IP67 -20 ... 80 PTSRB0041V3

0 ... 10 30 IP67 -20 ... 80 PTSRB0101V30 ... 16 48 IP67 -20 ... 80 PTSRB0161V30 ... 25 50 IP67 -20 ... 80 PTSRB0251V30 ... 40 80 IP67 -20 ... 80 PTSRB0401V3

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type-1 ... 1 6 IP67 -20 ... 80 PTSRV1011A30 ... 1 3 IP67 -20 ... 80 PTSRB0011A30 ... 4 12 IP67 -20 ... 80 PTSRB0041A3

0 ... 10 30 IP67 -20 ... 80 PTSRB0101A30 ... 16 48 IP67 -20 ... 80 PTSRB0161A30 ... 25 50 IP67 -20 ... 80 PTSRB0251A30 ... 40 80 IP67 -20 ... 80 PTSRB0401A3

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type-1 ... 1 6 IP65 -20 ... 70 PTHRV1011A20 ... 1 3 IP65 -20 ... 70 PTHRB0011A20 ... 4 12 IP65 -20 ... 70 PTHRB0041A2

0 ... 10 30 IP65 -20 ... 70 PTHRB0101A20 ... 16 48 IP65 -20 ... 70 PTHRB0161A20 ... 25 50 IP65 -20 ... 70 PTHRB0251A20 ... 40 80 IP65 -20 ... 70 PTHRB0401A2

Page 576: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

25-3

Electronic Pressure Transmitters

16

17

18

19

20

21

22

24

23

25

26

27

28

Pressure Transmitter with HMI (3-wire, 0-10 V)

Accessory

Electronic Differential Pressure Transmitters are microprocessor-controlled pressure measurement devices for a differential pressure range of 0 ... 20 bar. They are suitable for an extremely wide range of applications, including the precision recording and monitoring of system pressure. They come complete with an angled M12X1 plug and are mounted directly to the pipe via two G1/4" internal thread connections.Features:

• Configurable as 0/2...10V or 0/4...20 mA (3-wire)• Adjustable attenuation filter• LCD graphical display (Human-Machine-Interface models, only) can be swiveled for better

readability; display can be rotated in 90o steps by software for better readability; HMI can be freely swiveled 310o

• Self-monitoring electronics• Power supply 24 VAC/DC (3-wire models)• Power supply 18-35 V DC (2-wire models)

Pressure Transmitter with HMI (2-wire)

Pressure Transmitter without HMI (3-wire)

Pressure Transmitter with HMI (3-wire)

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type-1 ... 1 6 IP65 -20 ... 70 PTHRV1011V30 ... 1 3 IP65 -20 ... 70 PTHRB0011V30 ... 4 12 IP65 -20 ... 70 PTHRB0041V3

0 ... 10 30 IP65 -20 ... 70 PTHRB0101V30 ... 16 48 IP65 -20 ... 70 PTHRB0161V30 ... 25 50 IP65 -20 ... 70 PTHRB0251V30 ... 40 80 IP65 -20 ... 70 PTHRB0401V3

Field configuration tool CFT1

Electronic Differential Pressure transmitter for gas and liquid (Smart SN DIFF)

Media temp. -20 ... 80 oC

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type0 ... 0,1 0,9 IP65 -20 ... 70 PTHDM1002A20 ... 0,3 0,9 IP65 -20 ... 70 PTHDM3002A2

0 ... 1 3 IP65 -20 ... 70 PTHDB0012A20 ... 3 9 IP65 -20 ... 70 PTHDB0032A20 ... 6 21 IP65 -20 ... 70 PTHDB0062A2

0 ... 20 60 IP65 -20 ... 70 PTHDB0202A2

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type0 ... 0,1 0,9 IP67 -20 ... 80 PTSDM1002V30 ... 0,3 0,9 IP67 -20 ... 80 PTSDM3002V3

0 ... 1 3 IP67 -20 ... 80 PTSDB0012V30 ... 3 9 IP67 -20 ... 80 PTSDB0032V30 ... 6 21 IP67 -20 ... 80 PTSDB0062V3

0 ... 20 60 IP67 -20 ... 80 PTSDB0202V3

Pressure range (bar) Max. pressure (bar) Protection class Ambient temperature (oC) Type0 ... 0,1 0,9 IP65 -20 ... 70 PTHDM1002V30 ... 0,3 0,9 IP65 -20 ... 70 PTHDM3002V3

0 ... 1 3 IP65 -20 ... 70 PTHDB0012V30 ... 3 9 IP65 -20 ... 70 PTHDB0032V30 ... 6 21 IP65 -20 ... 70 PTHDB0062V3

0 ... 20 60 IP65 -20 ... 70 PTHDB0202V3

Page 577: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

25-4

Piezo-resistive transmitters

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Piezo-resistive transmitters

Double range differential pressure transmitter for air-conditioning/ventilation. For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental protection.

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz

Differential pressure transmitter for air (DPTM)

Kind of pressure differential pressure, relative

Pressure connection 6mm hose pipe

Electrical connection M20x1,5

Protection class IP54

Housing material ABS and POM

Sensing method piezoresistive

Sensing element material ABS + POM

Media temp. 0 ... 50 oC

Medium gaseous

Ambient temperature 0 ... 50 oC

Additional description Duct Kit DPSK included in delivery of single package.• Adjustable by jumper to the next higher pressure range.• Factory settings: see column "pressure range". Full scale

pressure range see data sheet

Pressure range Max. pressure TypePa kPa

-50 ... 50 20 DPTM50-100 ... 100 20 DPTM110-500 ... 500 20 DPTM550

-1000 ... 1000 20 DPTM11000 ... 100/250 20 DPTM1000 ... 250/500 20 DPTM250

0 ... 500/1000 20 DPTM5000 ... 1000/2500 40 DPTM1000

0 ... 5000/10000 60 DPTM5000

Page 578: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

25-5

Piezo-resistive transmitters

16

17

18

19

20

21

22

24

23

25

26

27

28

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc

Accessories

Pressure range Max. pressure TypePa kPa

-50 ... 50 20 DPTM50D-100 ... 100 20 DPTM110D-500 ... 500 20 DPTM550D

-1000 ... 1000 20 DPTM1100D0 ... 100/250 20 DPTM100D0 ... 250/500 20 DPTM250D

0 ... 500/1000 20 DPTM500D0 ... 1000/2500 40 DPTM1000D

0 ... 5000/10000 60 DPTM5000D

Pressure range Max. pressure TypePa kPa

-50 ... 50 20 DPTM52-100 ... 100 20 DPTM112-500 ... 500 20 DPTM552

-1000 ... 1000 20 DPTM11020 ... 100/250 20 DPTM1020 ... 250/500 20 DPTM252

0 ... 500/1000 20 DPTM5020 ... 1000/2500 40 DPTM1002

0 ... 5000/10000 60 DPTM5002

Duct Kit, including 2m silicone-hose and 2 joining pipes DPSJ with screws DPSK

Mounting brackets L-shaped DPSL

Page 579: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

25-6

Accessories

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Accessories

Flanged Pressure Mediators

Flanged Pressure Mediators, teflon surfaced

Flanged Pressure Mediators with 1 m pipeline

Flanged Pressure Mediators with 1 m pipeline, teflon surfaced

Pressure Mediator

Pressure Mediator, teflon surfaced

Screw-in Pressure Mediator

Syphons

Accessories

Accessories for Differential Switches / Transmitters

Accessories for Pressure Switches / Transmitters

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -40 ... 120 ZFV184-5080 0,15 -40 ... 120 ZFV184-80

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -40 ... 120 ZFV184-50PTFE80 0,15 -40 ... 120 ZFV184-80PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -30 ... 300 ZFV185-5080 0,15 -30 ... 300 ZFV185-80

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,3 -30 ... 300 ZFV185-50PTFE80 0,15 -30 ... 300 ZFV185-80PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,4 -30 ... 120 ZFV162-50

DN size (mm) Lowest pressure point (bar) Media temp. (oC) Type50 0,4 -30 ... 120 ZFV162-50PTFE

DN size (mm) Lowest pressure point (bar) Media temp. (oC) TypeG1 0,5 -30 ... 120 ZFV749G1 0,5 -30 ... 120 ZFV749 - V191

Syphon for high temperature, steel, U-shape U430B

Syphon for high temperature, steinless steel, U-shape U480B

Syphon for high temperature, steel, circular K430D

Syphon for high temperature, stainless steel, circular K480D

Adapter NPT1

Pressure surge reducer DMW

Sealing P2

Shut-off valve combination, 3-venting valve VKD3

Shut-off valve combination, 5-venting valve VKD5

Male adapter union, O-ring NBR MAU8/MS

Male adapter union, O-ring FPM MAU8/NST

Page 580: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Solenoid Valves Page

Standard Solenoid Valves 26-2Solenoid Valves, component tested 26-4

Page 581: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

26-2

Standard Solenoid Valves

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Standard Solenoid Valves

The 2/2-way valves of the AB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are suitable for neutral liquids, such as water, hydraulic oil, oils and fats without additives.

Plug

The 2/2-way valves of the GB-series are suitable for general applications and is not dependent operationally on a specific minimum differential pressure. They are ideal choice for installation in situations where differential pressure fluctuate greatly and are not possible to determine precisely in advance. They are also suitable for use in heating and cooling circuits.

Brass valve body, Sealings: Perbunan

Solenoid valves for liquid medium (AB)

Valve application liquid

Materials Casing: brass Internal parts: stainless steel Membrane: Perbunan

Media temp. -10 ... 90 oC

Ambient temperature -10 ... 55 oC

Operating mode normally closed

Power supply 230V 50Hz

Working range 0 ... 10 bar

DN size Kvs value Connections Typemm

10 1,8 G3/8 AB1013 3,5 G1/2 AB1320 8,6 G3/4 AB2025 11 G1 AB2525 11 G1 1/4 AB3240 30 G1 1/2 AB4040 30 G2 AB50

Device plug with LED-display for voltage 200V - 240 VAC/DC ST221

Solenoid valves for gaseous and liquid medium (GB)

Valve application gaseous/liquid

Materials Casing: (see below), either brass or stainless steel (1.4410) Internal parts: stainless steel

Media temp. -10 ... 90 oC

Ambient temperature -10 ... 55 oC

Operating mode normally closed

Power supply 230V 45..60Hz

Working range 0 ... 16 bar

DN size Kvs value Connections Typemm

12 2,8 G1/2 GB1220 5 G3/4 GB2025 10 G1 GB25

Page 582: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

26-3

Standard Solenoid Valves

16

17

18

19

20

21

22

24

23

25

26

27

28

Stainless steel 1.4410 valve body, Sealings: Viton(R)

Plug

The GK series piston-type solenoid valves are ideal for use as shutoff valves in heating and process engineering systems, e. g. hot water and steam. The valves require no minimum differential pressure.

Screwed version, material: brass

Flanged version, material: cast iron GG25

Plug

DN size Kvs value Connections Typemm

12 2,8 G1/2 GB12VA20 5 G3/4 GB20VA25 10 G1 GB25VA

Device plug with LED-display for voltage 200V - 240 VAC/DC ST221

Solenoid valves for media up to 180 degree (GK)

Valve application gaseous/liquid

Materials Casing: (see below), either brass or cast iron GG25, Membrane: viton and graphit

Media temp. 0 ... 180 oC

Ambient temperature 0 ... 55 oC

Operating mode normally closed

Power supply 230V 50Hz

Working range 0 ... 10 bar

DN size Kvs value Connections Typemm

13 3,7 G1/2 GK1320 5 G3/4 GK2025 10 G1 GK2532 16 G1 1/4 GK3240 16 G1 1/2 GK4050 36 G2 GK50

DN size Kvs value Connections Typemm

25 10 flange GK25F32 16 flange GK32F40 16 flange GK40F50 36 flange GK50F

Device plug with LED-display for voltage 200V - 240 VAC/DC ST221

Page 583: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

26-4

Solenoid Valves, component tested

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Solenoid Valves, component tested

The 2/2-way valves of the AT-series are suitable for potable water and is not dependent operationally on a specific minimum differential pressure, and right through to maximum pressure.

Plug

The 2/2-way valves of the AV-series are designed for safety function in liquid fuel supply systems. The valves prevent unintended draining of the system and storage tanks in case of malfunction of burner or filter.

Plug

Solenoid valves for potable water (AT)

Valve application liquid

Materials Casing: brass Internal parts: stainless steel Membrane: EPDM

Media temp. 0 ... 90 oC

Ambient temperature 0 ... 55 oC

Operating mode normally closed

Power supply 230V 50Hz

Certificates VDE-approval according EN 60730 up to 50 degree

Working range 0 ... 10 bar

DN size Kvs value Connections Typemm

10 1,8 G3/8 AT1013 3,5 G1/2 AT1320 8,6 G3/4 AT2025 11 G1 AT2525 11 G1 1/4 AT3240 30 G1 1/2 AT4040 30 G2 AT50

Device plug with LED-display for voltage 200V - 240 VAC/DC ST221

Solenoid valves for neutral liquid medium (AV)

Valve application fuel oil

Materials Casing: brass Internal parts: stainless steel Membrane: Viton

Media temp. 0 ... 90 oC

Ambient temperature 0 ... 55 oC

Operating mode normally closed

Power supply 230V 50Hz

Certificates 5S262 according to DIN EN ISO 23553-1:2009-10

DN size Kvs value Working range Connections Typemm bar

10 1,8 -0,6 ... 4 G3/8 AV102MS210 1,8 -0,6 ... 4 G1/2 AV103MS213 3,5 -0,6 ... 4 G1/2 AV131MS220 8,6 -0,6 ... 10 G3/4 AV201MS225 11 -0,6 ... 10 G1 AV251MS225 11 -0,6 ... 10 G1 1/4 AV252MS240 30 -0,6 ... 10 G1 1/2 AV401MS240 30 -0,6 ... 10 G2 AV402MS2

Device plug with LED-display for voltage 200V - 240 VAC/DC ST221

Page 584: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Temperature sensors/transmitters Page

Temperature sensors Pt100, industrial, stainless steel 27-2Temperature sensors, ABS housing 27-3

Page 585: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

27-2

Temperature sensors Pt100, industrial, stainless steel

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Temperature sensors Pt100, industrial, stainless steel

The temperature sensor consist completely of stainless steel.

Accessories

Immersion probe temperature sensor, stainless steel (P)

Protection class IP67

Temperature element Pt100

Temperature range -50 ... 400 oC

Mounting place in well

Additional description • Cable entry: M16X1.5• Immersion probe with screw-in thread G1/2"• Material: Tube: high-grade steel 1.4571

Immersion depth Typemm

100 P100-100150 P100-150200 P100-200250 P100-250

Immersion tube, G1/2, immersion length 100 mm G12-100

Immersion tube, R1/2, immersion length 100 mm R12-100

Immersion tube, 1/2 NPT, immersion length 100 mm N12-100

Immersion tube, G1/2, immersion length 150 mm G12-150

Immersion tube, R1/2, immersion length 150 mm R12-150

Immersion tube, 1/2 NPT, immersion length 150 mm N12-150

Immersion tube, G1/2, immersion length 200 mm G12-200

Immersion tube, R1/2, immersion length 200 mm R12-200

Immersion tube, 1/2 NPT, immersion length 200 mm N12-200

Immersion tube, G1/2, immersion length 250 mm G12-250

Immersion tube, R1/2, immersion length 250 mm R12-250

Immersion tube, 1/2 NPT, immersion length 250 mm N12-250

Page 586: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

27-3

Temperature sensors, ABS housing

16

17

18

19

20

21

22

24

23

25

26

27

28

Temperature sensors, ABS housing

The temperature sensors are designed for universal use in systems of machine construction, process control, HVAC, environmental and agricultural area.

The temperature sensors are designed for universal use in systems of machine construction, process control, HVAC, environmental and agricultural area.

The temperature sensors are designed for universal use in systems of machine construction, process control, HVAC, environmental and agricultural area.

Fast Temperature Sensor, Industrial/HVAC (STF)

Protection class IP65

Temperature range -20 ... 300 oC

Mounting place in pipe

Cable length 2,5 m

Additional description Material: Screw connection: Stainless steel 1.4571, Sensor well: Stainless steel 1.4571, Internal gasket: PTFE

Temperature element Immersion depth Sensing element (dia x L) Typemm mm; mm

Pt100 max. 75 4; 75 STF21-75Pt1000 max. 75 4; 75 STF31-75Pt100 max. 220 4; 220 STF21-220

Pt1000 max. 220 4; 220 STF31-220

Surface temperature sensor, Industrial/HVAC (ALF)

Protection class IP65

Temperature range -30 ... 110 oC

Mounting place strap on pipe

Temperature element TypePt100 ALF21Pt1000 ALF31

Immersion temperature sensor for Industrial, HVAC (TF)

Protection class IP65

Temperature range -30 ... 150 oC

Mounting place in pipe

Immersion depth max. 150 mm

Temperature element TypePt100 TF21Pt1000 TF31

Page 587: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

27-4

Temperature sensors, ABS housing

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16The temperature sensors are designed for universal use in systems of machine construction, process control, HVAC, environmental and agricultural area.

The temperature sensors are designed for universal use in systems of machine construction, process control, HVAC, environmental and agricultural area.

Air duct temperature sensor, Industrial/HVAC (KF)

Protection class IP65

Temperature range -30 ... 150 oC

Mounting place air duct

Immersion depth max. 250 mm

Temperature element TypePt100 KF21Pt1000 KF31

Room temperature sensor for Industrial, HVAC (RF)

Protection class IP65

Temperature range -50 ... 90 oC

Mounting place inside unit

Temperature element TypePt100 RF21Pt1000 RF31

Page 588: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

16

17

18

19

20

21

22

24

23

25

26

27

28

Hygrostats Page

Hygrostats 28-2

Page 589: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

28-2

Hygrostats

http://products.ecc.emea.honeywell.com/europe

16

17

18

19

20

21

22

23

24

25

26

27

28

16Hygrostats

Line voltage humidistats for (de)humidification 2-point control in air conditioning systems. Also applicable for swimming pools (dehumidification).

Room humidistat H6120

Duct humidistat H6045

Room and air duct humidistats (H)

R.H. setpoint range 35 ... 100 %rh

(De) Humidification application

D + H

Additional description Maximum air flow speed for ducts: 8 m/s.

R.H. hysteresisswitching point

Ambienttemperature

Mountingplace

Immersionepth

Switchfunction/capacity

Protectionclass

Type

%rh oC mm

4 0 ... 60 internal wall – SPDT 230Vac /5A (0,2A) IP30 H6120A1000

R.H. hysteresisswitching point

Ambienttemperature

Mountingplace

Immersionepth

Switchfunction/capacity

Protectionclass

Type

%rh oC mm

5 -10 ... 65 air duct 222 SPDT 250Vac/15A (8A) IP65 H6045A1002

Page 590: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

29

30

31

32

33

34

35

36

38

37

39

40

41

42

Flow monitors Page

Mechanical flow monitors 29-2Electronic flow monitors 29-3

Page 591: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

29-2

Mechanical flow monitors

http://products.ecc.emea.honeywell.com/europe

29

30

31

32

33

34

35

36

37

38

39

40

41

42

Mechanical flow monitors

The flow switches are designed for monitoring flow rates in pipes and ducts employed in HVAC applications.For monitoring flow of non-aggressive gases in air ducts of air conditioning systems and air treatment systems.

The flow switches are designed for monitoring flow rates in pipes employed in HVAC applications.For monitoring flow in water, oil, cooling circuits, and lubrication systems.

Liquid

Paddle flow switches for air (S6040)

Protection class IP65

Switch function/capacity SPDT, capacity 250Vac, (8)15 A

Setpoint device screw

Max. media temperature 85 oC

Setpoint range 2,5..9,2m/s

Max. pressure 0,25 bar

TypeS6040A1003

Paddle set PA1

Paddle flow switches for liquid (S6065)

Protection class IP65

Switch function/capacity SPDT, capacity 250Vac, (8)15 A

Setpoint device screw

Approvals TUEV-approval

Max. media temperature 120 oC

Setpoint range 0,6..165 m3/h pipe size dependent

Media Max. pressure Typebar

liquid non-aggressive 11 S6065A1003liquid aggressive 30 S6065A2001

Page 592: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

29-3

Electronic flow monitors

29

30

31

32

33

34

35

36

38

37

39

40

41

42

Electronic flow monitors

Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit type ASL...For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever flow processes in air or neutral gases have to be detected.

Sensor

Evaluation Unit

The high reliable compact electronic flow switch is designed for detecting air flow in ducts. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.

Process connection PG7 + mounting flange

Electronical air flow switch for air (ASL)

Protection class sensor: IP32

Output signal evaluation unit: relay SPST 8A, 250Vac, switch point adjustable from 0,1..20 m/s air speed

Additional description Media temperature at sensor: -20..100 oC.

Mounting place Immersion depth Power supply Typemm Vac; VA

air duct 150 –; – SLF15

Mounting place Immersion depth Power supply Typemm Vac; VA

universal – 24; 3 ASL453/24universal – 230; 3 ASL453

Electronic flow switches for air, compact version (KSL)

Protection class IP65

Switch function/capacity SPDT, capacity 250 Vac, 10(2) A

Immersion depth 115 mm

Setpoint range 0,1..30 m/s

Max. media temperature 80 oC

Max. pressure 10 bar

Additional description LED's available for indication of power supply and switch status.

Power supply TypeVac; VA

24; 10 KSL24230; 10 KSL230

Page 593: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

29-4

Electronic flow monitors

http://products.ecc.emea.honeywell.com/europe

29

30

31

32

33

34

35

36

37

38

39

40

41

42

Fluid flow monitor consisting of two parts: the sensor type SWF.. and the belonging evaluation unit type ASW...

Sensor

Evaluation unit

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.

Process connection G1/2"

Electronical flow switch for liquid (ASW)

Protection class sensor: IP65; evaluation unit: IP32

Output signal evaluation unit: relay SPST 8A, 250Vac, switch point adjustable, lowest 0,03 m/s fluid speed

Additional description For sensor:• media temperature 0..80 oC• sensing element steel

Power supply Mounting place Immersion depth Connection diameter TypeVac; VA mm inch

–; – in pipe 25 G1/4 SWF62–; – in pipe 45 G1/2 SWF62L

Power supply Mounting place Immersion depth Connection diameter TypeVac; VA mm inch

230; 3 universal – – ASW45424; 3 universal – – ASW454/24

Electronic flow switches for liquid, compact version (KSW)

Protection class IP65

Switch function/capacity SPDT, capacity 250 Vac, 10(2) A

Immersion depth 20 mm

Media liquid and air

Setpoint range 0,05..3 m/s

Max. media temperature 80 oC

Max. pressure 30 bar

Additional description LED's available for indication of power supply and switch status.

Power supply TypeVac; VA

24; 4 KSW24230; 4 KSW230

Page 594: Environmental Controls - UNICOM · 2013. 8. 30. · 0904033 20-19 0904034 20-19 0904052 20-21 0904053 20-21 0904054 20-21 0904055 20-21 0904056 20-21 0904057 20-21 0904058 20-21 0904059

Product catalog

Honeywell Srl ACS Environmental ControlsVia Philips, 1220052 MonzaTelefono: +39 039 2165.1Email: [email protected]

Honeywell ΕΠΕACS Environmental ControlsΠολυτεχενείου, 2514122, Νέο ΗράκλειοΤηλ.: +30 210 2848049Φαξ: +30 210 2848055

Honeywell Middle EastEnvironmental & Combustion ControlsEMAAR Business ParkSheik Zayed Road, Building 2,Level 2, Office 201, Dubai, U.A.E.Phone: +971 4 4505800 Fax: +971 4 4505900Email: [email protected]

UK3B-0007IT0H-R0713

Subject to change without notice - All rights reserved www.honeywell.com

AC

S E

nviro

nmen

tal C

ontr

ols

Pro

duc

t ca

talo

g