Ductile Iron Cement Lined - jindalsaw.com.au · AS/NZS 2040 or bituminous seal coat: 1. Ordinary...
Transcript of Ductile Iron Cement Lined - jindalsaw.com.au · AS/NZS 2040 or bituminous seal coat: 1. Ordinary...
Internal Lining External Coating End Connections
Cement Mortar with optional epoxy seal coat to AS/NZS 2040 or bituminous seal coat:
1. Ordinary Portland Cement (OPC)
2. Sulphate Resistant Cement (SRC)
3. Blast Furnace Slag Cement (BFSC)
4. High Alumina Cement (HAC)
1. Zn-Al primer (mean mass 400 gm/m2) + Blue/Red liquid epoxy (min. 80 μm DFT)
2. Zn primer (mean mass 200 gm/m2) + Blue/Red liquid epoxy (min. 80 μm DFT)
3. Zn primer (mean mass 200 gm/m2) + Polyurethane as per EN 15189
4. Zn primer (mean mass 200 gm/m2) + Bitumen coating
1. Socket Push-on joint (flexible jointing) with EPDM gasket
2. Flange To AS 4087 / AS 2129 / ANSI Class drillings
3. Patented JSAW-LOCK Double Socket Full Restraint joint ends with welded bead ring
Anti-Corrosion Fittings
External anti-corrosion options also available through tailored polyethylene sleeving or our innovative pre-insulated ductile iron pipe system
For the full range of AS/NZS 2280 certified fittings see our fittings catalogue
OPTIONS
DE
Size Range
DN225 – DN750
Nominal Pressure
PN20
Effective Length
5.5m as standard(custom lengths from 5 - 5.85m)
Fully Compliant and Certified
AS/NZS 2280
EDN
OUTSIDE DIAMETER (DE) PIPE WALL
THICKNESS, E (mm)
CEMENT MORTAR LINING
THICKNESS(mm)OD (mm) Tolerance (mm) PN20
225 259 +1, -2 4.5 5
250 286 +1, -2 4.6 5
300 345 +1, -2 4.6 5
375 426 ± 2 4.8 5
450 507 ± 2 5.4 5
500 560 ± 2 5.8 5
600 667 ± 2 6.7 5
750 826 ± 2 8.0 6
TECHNICAL DATA
Applied through a centrifugal process, cement mortar lining offers excellent resistance against corrosion while providing superior hydraulic performance. Ideal for potable and waste-water applications. The cement lining creates a smooth and dense internal surface. Ductile Iron Cement Lined (DICL) pipelines can be quickly and safely installed using automatic flexible joints. Due to their high angular deviation, there is the potential to reduce the number of fittings increasing the rate of installation, even in the case of land with irregular elevations. AS/NZS 2280 and ISO 2531/7186 certification.
AS/NZS 2280 PN20 – Pipeline and FittingsDuctile Iron Cement Lined