HOW DID OUR ANTIBODY PERFORM?
CUSTOMER REVIEW: GSK3β Polyclonal Antibody (STJ93447)
WHAT WAS USED?Primary antibody: STJ93447. GSK3β PolyclonalAntibody. 100µl
Provider: St John's Laboratory
Dilution ratio: 1:1000
Application: Western Blot.
Image: In HeLa cell line, the target band was detected by STJ93447. GSK3β Polyclonal Antibody. In A549 cell line, there was no target band detected by STJ93447 GSK3β Polyclonal Antibody.
WHAT WAS THE PROTOCOL?Treatment of materials: When cells were cultured to 70%-80% plating density, lysis buffer with protease inhibitors (Sigma) and equal volume of 2X loading buffer were added for 10 min water bath at 100˚C.Gel electrophoresis: 10% polyacrylamide gel, constant voltage 160 V, 60 min.Transfer: 0.45 nm PVDF membrane, 1 piece of gel (wet transfer), constant voltage 100 V 60 min.Blocking: 1X TBST with 5% skimmed milk powder for 2 hr.Primary antibody probing: primary antibody was added to the solution of 1X TBST with 5% skimmed milk powder, 4˚C for overnight.Membrane wash: 1X TBST wash for 3 times.Secondary antibody probing: secondary antibody was added to the solution of 1X TBST with 5% skimmed milk powder with 1:10000 dilution ratio, for 1.5 hr.Membrane wash: 1X TBST wash for 3 times.Visualization: ECL visualization for 5 min (the visualization time was determined by actual result. It was ensured that the visualization time was identical for the same antigen).
WHAT WAS THE PROTOCOL?
Gel electrophoresis information: 10% polyacrylamide gel, constant voltage 160 V, 60 min.Transfer information: 0.45 nm PVDF membrane, 1 piece of gel (wet transfer), constant voltage 100 V 60 min.
No. Antigen Loading amount
Primary antibody
Primary antibody dilution
ratio
Secondaryantibody dilution
ratio
Target band KD
Visualization time
1 HeLa lysate 10 µg St J93447. GSK3β
Polyclonal Antibody
1:1000
1:10000 47KD 30S
2 A549 lysate 10 µg 1:10000 47KD 30S
WHAT DID THE CUSTOMER THINK?
Testing results were provided by BPI laboratory. They stated that “In HeLa cell line, the target band was detected by GSK3β Polyclonal Antibody (STJ93447). In A549 cell line, there was no target band detected by GSK3β Polyclonal Antibody (STJ93447).”
“WE INVITE YOU TO TEST OUR PRODUCTS”
Our aim is to not only connect our customers with the best product, but to also give them the opportunity to test the product’s performance risk free.
Contact Us: [email protected]
1. Choose 5 Trial Size Samples from our free sample list 2. Complete the free sample application: http://www.stjohnslabs.com/free-sample3. Receive your antibody 4. Submit your review 5. Receive your 30% off your next order
Get Your Free Samples in 5 Easy Steps
Follow Us for Weekly Independent Validation Reviews
@StJohnsLabsSt John's Laboratory Ltd
St John's Laboratory Ltd St John's Laboratory Ltd
http://www.slideshare.net/stjohnslabs