A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in...

18
A Precise Measurement of the Stark Shift in the 6P 1/2 ->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S. Charles Doret Previous work by Andrew Speck ’00, Paul Friedberg ’01, D.S. Richardson, PhD

Transcript of A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in...

Page 1: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

A Precise Measurement of the Stark Shift inthe 6P1/2->7S1/2 378 nm Transition in

Thallium

Final Thesis Talk

May 13, 2002

S. Charles Doret

Previous work by Andrew Speck ’00, Paul Friedberg ’01,

D.S. Richardson, PhD

Page 2: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

[Fow70]

[DeM94]kS

tark

kH

z/(k

V/c

m)2

PresentMeasurement

Year

Summary of Stark Shift Measurements

kStark = 103.34(37) kHz/(kV/cm)2

∆ν = kStarkE2

Page 3: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Why Bother?

- Low energy AMO physics can be used to set stringent limits onfundamental physical quantities

- Parity non-conservation measurements give both evidence for andtests of fundamental physics

- Of interest here: Qw , predicted by elementary particle theory

According to Atomic Physics:

EPNC = Qw * C(Z)

Group Element Experimental Precision

Atomic Theory Precision

Colorado '88 Cesium 2% 1% Oxford '91 Bismuth 2% 8%

UW '93 Lead 1.2% 8% Berkeley Ytterbium ongoing Isotopic ratios…UW '95 Thallium 1.2% 2.5% (new, 2001)

Colorado '97 Cesium 0.35% ~ 1% (or less)

Page 4: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Where does kStark come into play?- C(Z) based on an infinite sum of E1 matrix elements*

So, if your wavefunction approximations can accuratelycalculate kStark, they should be adequate for an accuratedetermination of C(Z) as well!

* details available upon request

- kStark calculable from an infinite sum over allwavefunctions

rdrevv 3

2*

1 ΨΨ�

Page 5: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

How to measure?

2nd order Perturbation Theory:

∆ν = kStarkE2

Electric Field Plate

CollimatedAtomic Beam

Transverse LaserProbe

Interaction Region: ?E 0

Page 6: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Optical System:

ρ = b/a

Cavity length

Frequency Stabilization:

Frequency Tuning:

1) Adjust 0 < ρ < 1 ~ 800 MHz range

-susceptible to mis-measurement of FSR, slow, manual

2) Acousto-Optic Modulator precisely shifts laser frequency at fixed ρ ~ 100 MHzrange

- synthesizer precision, instantaneous, computer control, steering problems

n λHeNe / 4 (n+1) λHeNe / 4m λdiode / 4

Page 7: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Optical Table

Interaction Region

Doubling Cavity

Page 8: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

AOM λ/4

wavemeter

Locking system

external cavity diode laser

755 nm, ~12 mW

opticalisolator PBS

RF frequencysynthesizer

(90-120 MHz)

external resonantfrequency-doubling (‘bowtie’ cavity)

f0+νAOM

(νAOM)

f 0+2

ν AO

Mf0

2f0+4νAOMTo Lock-ins

PMT 2

PMT 1

collimatorschoppingwheel Tl oven

high-vacuum

ATOMIC BEAM

378 nm, ~0.5 µWchopping wheel

E-field plates

Atomic Beam and Optical System Layout

Page 9: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Data Collection/Signal Processing

Chopping System:

- Laser Beam chopping rejects any noise with frequencycomponents other than the modulation frequency – 1400 Hz

- Atomic Beam chopping to correct for optical table drifts,beam density fluctuations, etc. – 1Hz

Division/Subtraction Schemes:

- Extra PMT for laser beam intensity normalization

- Interested in difference signal A-B

- Collect data in ABBA format to minimize the effects of lineardrifts

Page 10: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

- Sequentially lock the diode laser, calibrate “ρ”- Scan over single line of 205Tl. Fit data to Voigt transmission profile

ρ Frequency Scan:

Measurement Methods

kStark 2)/25(

63

cmkV

MHz=

= 101kHz/(kV/cm)2

Page 11: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

∆S

Ε2

+–0

(1) Lock laser to inflection point of transmission curve (dip), measure S = T/N (E = 0)

(3) Repeat sequence with altered Electric field values, but same ∆f.

(2) - Turn on Electric field (E = E0) - Shift AOM frequency by appropriate amount (∆f); - Determine S’ and ∆S = S’ - S

∆f fixed

(4) Find y-intercept of linear fit -- value of E2 which exactly matches ∆f

Transmission Change:

Page 12: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Statistical Analysis

Final Statistical Error: 0.20 kHz/(kV/cm)2 (0.19%)

Std. Error

Page 13: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Systematic Error Analysis

Doppler Shifts:

δf = f∗ v/c

= 4*1014(300 m/s / 3*108 m/s) * 10-3 rad

= 0.4 MHz (0.38%)

4*1014(300 m/s / 3*108 m/s) * 10-4 rad

40 kHz (0.04 %)

Page 14: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

Correlation Plots

- Concerns about linear fit used to extract kStark with TransmissionChange method

Simulation: Measured:

Symmetric data collection on both sides since opposite effect

Page 15: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

- Should be no relation between E and kStark, but wecheck anyhow . . .

Page 16: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

ρ Scan Errors

Fitting Errors:

Page 17: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

ConclusionsFinal Values:

ρ Scan: 103.23(57) kHz/(kV/cm)2

Transmission Change: 103.41(39) kHz/(kV/cm)2

Combined Value: 103.34(37) kHz/(kV/cm)2

-Modest amount of data required before submission for publication inJune

[Fow70]

[DeM94]kS

tark

kH

z/(k

V/c

m)2

PresentMeasurement

Year

Theory% Error

Page 18: A Precise Measurement of the Stark Shift in the 6P …A Precise Measurement of the Stark Shift in the 6P 1/2->7S 1/2 378 nm Transition in Thallium Final Thesis Talk May 13, 2002 S.

FutureStark Induced Amplitude at 1283 nm: