SSeries SAP 50 Nylon air breather filter Dimensions · Nylon air breather filter SAP050 ... Nylon...

Post on 25-Apr-2018

230 views 10 download

Transcript of SSeries SAP 50 Nylon air breather filter Dimensions · Nylon air breather filter SAP050 ... Nylon...

Nylon air breather filter

SAP050 (Materials)

1 - Cover/Connection: Nylon

2 - Filter element: Impregnated paper

Polyurethane

3 - Pressurisation: Nylon

Galvanised steel

NBR

4 - Seal: NBR

Breather filter

Flow rate with Δp: 0,02 bar

Filtration lN/min

10 µm 204

Weights

SAP 050: 0,040 kg

1 2 3 4 5

SAP

Example: SAP50 G4 L10 A 0 P01

OOrrddeerr iinngg iinn ffoorrmmaatt iioonn

SSeerr iieess SSAAPP 5500

1

3

2

4

1

38

5 - Options

P01 MP Filtri standard

G 1/4”

G 3/8”

G 1/2”

G 3/4”

1/4” NPT

3/8” NPT

1/2” NPT

3/4” NPT

SAE 6

SAE 12

1 - Connection to reservoir

G1

G2

G3

G4

G5

G6

G7

G8

G9

G10

4 - Pressurisation valve

0 Without

1

2 - Filter element

L03 3 µm - Impregnated paper

LL10 10 µm - Polyurethane

3 - Seal

A NBR

Pressurisation valve 0,5 barOnly for connection : G2 - G3 - G4 - G6 G7 - G8 - G10

Quantity per packNumber of Parts

SAP50 10

Type SAP 50

Connection to reservoir “ A ”

G1

G 1/4”

G2

G 3/8”

G3

G 1/2”

G4

G 3/4”

G5

1/4” NPT

Dimensions

H1

12

14,5

H2

36

35

H3

48

50

Type SAP

50 G150 G250 G350 G450 G550 G650 G750 G850 G950 G10

D1

50,5

50,5

G6

3/8” NPT

G7

1/2” NPT

G8

3/4” NPT

G9

SAE 6

G10

SAE 12

DDiimmeennss iioonnssØ D1

A

H3

H2

H1

SAP 054

G 3/8”

G1/2”

-

1/2” NPT

-

SAP 075

G 1/2”

G 3/4”

-

1/2” NPT

3/4” NPT

H2

H3

H1

A

Ø D1

A/F

Type SAP

054075

Connection to reservoir “ A ”

Dimensions

G1

G 3/8”

G 1/2”

G2

G 1/2”

G 3/4”

G3

-

-

G4

1/2” NPT

1/2” NPT

G5

-

3/4” NPT

Type SAP

054 G1054 G2054 G4

075 G1075 G2075 G4075 G5

D1

54

75

H1

13,5

17

H2

51

64

H3

8

9

A/F (mm)

22

27

32

27

32

Nylon air breather filter

SAP 054 - 075 (Materials)

1 - Cover: Nylon

2 - Connection: Nylon

3 - Filter element: Impregnated paper

Flow rate with Δp: 0,02 bar

Filtration lN/min

SAP 054

3 µm 200

10 µm 250

SAP 075

3 µm 350

10 µm 400

1

2

3

SSeerr iieess SSAAPP 005544 -- 007755

DDiimmeennss iioonnss

OOrrddeerr iinngg ii nnffoorrmmaatt iioonn

SAP

Example: SAP 075 G4 L10 A P01

1 2 3Breather filter

4 - Seal

A NBR

3 - Filter element

L03 3 µm - Impregnated paper

L10 10 µm - Impregnated paper

5 - Options

P01 MP Filtri standard

4 5

Filter element

Example: A7 L10

1 3

Weights

SAP 054: 0,060 Kg

SAP 075: 0,150 Kg

2 - Connection to reservoir

39

1 - Size

Filter Filter element

054 A4

075 A7G1

G2

G3

G4

G5

H1

22

22

H1

H3

H2

AA/F

Ø 116

A/FA

VisualIndicator

VisualIndicator

Clogging indicator

Set pressure: - 0.062 bar ± 10%

Manual reset

Ø 116

Filtration lN/min lN/minSAP 115 1 SAP 115 2

Connection

2170

1830

2800

2800L10

A03

2330

1995

3000

3000L10

A03

G 1”M33x2

G 1 1/2”

Flow rate with Δp: 0,02 bar

Nylon air breather filter

SAP115 (Materials)

1 - Cover: Nylon

2 - Filter element: Microfibre

Impregnated paper

3 - Connection: Nylon

4 - Seals: NBR

FPM

SSeerr iieess SSAAPP 111155

DDiimmeennssiioonnss

Weight

SAP 115 1: 0,410 Kg

SAP 115 2: 0,525 Kg

4

1

2

3

SAP 115 1

SAP 115 2

40

Connection

ABC

A

G 1”

M33x2

G 1 1/2”

A/F

41

41

55

H1

171

171

176

H2

18

18

23

SAP 115 1 - Dimension

Connection

ABC

A

G 1”

M33x2

G 1 1/2”

A/F

41

41

55

H1

106

106

111

H2

18

18

23

H3

H2

H3

17

17

22

H3

17

17

22

SAP 115 2 - Dimension

1

2

3 a

3 b

3 c

3 d

OOrrddeerr iinngg ii nnffoorrmmaatt iioonn

SAP115

Example: SAP115 2 A A03 A 1 B P01

1 2 3 4 5

A115

Example: A115 2 A03 P01

1 3

6 - Clogging indicator

A Without

B Visual indicator

7 - Options

P01 MP Filtri standard

1 - Length

1

2

2 - Connection

A G 1”

B M33x2

C G 1 1/2”

4 - Seal

A NBR

V FPM

3 - Filter element

A03 3 µm - Microfibre

L10 10 µm - Impregnated paper

6 7

7

Item.

1

2

3

3a

3b

3c

3d

Q.ty

1

1

1

1

1

1

1

Description

Complete filler cap

Filter Element

Indicator kit

Visual indicator

Seal

Indicator securing screw

O-R indicator

TAP SAP 115 spare parts

Changing the filter element in SAP 115 series filler caps

1 Thoroughly clean the filler cap and

adjacent parts.

2 Unscrew and raise the cover.

3 Replace the filter element.

4 Screw the cover.

SSppaarr ee ppaarr ttss

Filler cap seriesSAP 115

See order table

See order tablee

NBR FPM

02005187 02005188

S62P01

O-R 3106 Ø 26,64 X 2,62

01022670

O-R 2112 Ø 28,3 x 1,78

Filter element

5 - Variants

0 Standard

1 With anti-splash feature

41

Breather filter