Heat pump combination heater Outdoor EVLQ08CAV3
Indoor EHYHBH08AAV3U
Indoor unit sound power (*) [dB(A)] 42.0Outdoor unit sound power (*) [dB(A)] 62.0
Water heating Declared load profile - XLEnergy efficiency class - A
Space heating Energy efficiency class 55°C (High temp. app.) -Average climate (Design temperature = –10°C)Water heating Water heating energy efficiency (ηwh) [kW] 95.8
Annual electricity consumption (AEC) [kWh] 0.00Space heating Prated (declared heating capacity) @ –10°C [kW] 6.40
Seasonal space heating efficiency (ηs) [%] 127
Annual energy consumption [kWh] 4,020off peak operation function integrated in Heat pump Y/NColder climate (Design temperature = –22°C)Water heating Water heating energy efficiency (ηwh) [kW] 95.8
Annual electricity consumption (AEC) [kWh] 0.00Space heating Prated (declared heating capacity) @ –22°C [kW] 6.90
Seasonal space heating efficiency (ηs) [%] 111
Annual energy consumption [kWh] 5,900Warmer climate (Design temperature = 2°C)Water heating Water heating energy efficiency (ηwh) [kW] 95.8
Annual electricity consumption (AEC) [kWh] 0.00Space heating Prated (declared heating capacity) @ –2°C [kW] 6.60
Seasonal space heating efficiency (ηs) [%] 157
Annual energy consumption [kWh] 2,130Ecodesign technical dataProduct description Air-to-water heat pump Y/N Yes
Water-to-water heat pump Y/N noBrine-to-water heat pump Y/N noLow-temperature heat pump Y/N noEquipped with a supplementary heater Y/N YesHeat pump combination heater Y/N Yes
Air to water unit Rated airflow (outdoor) [m3/h] 2,700
Brine/water to water unit Rated water/brine flow (outdoor H/E) [m3/h]
Other Capacity control - Inverter
Poff (Power consumption Off mode) [kW] 0.013
Pto (Power consumption Thermostat off mode) [kW] 0.006
Psb (Power consumption Standby mode) [kW] 0.013
PCK (Power crankcase heater model) [kW] 0.000
Qelec (Daily electricity consumption) [kWh] 0.00
Qfuel (Daily fuel consumption) [kWh] 19.9
Part load conditions space heating average climate(A) condition (-7°C) Pdh (declared heating capacity) [kW] 5.70
COPd (declared COP) - 2.38
Cdh (degradation coefficient) - 1.00(B) condition (2°C) Pdh (declared heating capacity) [kW] 3.40
COPd (declared COP) - 2.99
Cdh (degradation coefficient) - 1.00(C) condition (7°C) Pdh (declared heating capacity) [kW] 3.50
COPd (declared COP) - 4.20
Cdh (degradation coefficient) - 1.00(D) (D) condition (12°C) Pdh (declared heating capacity) [kW] 3.30
COPd (declared COP) - 5.82
Cdh (degradation coefficient) - 1.00(E) Tol (temperature operating limit) Tol (temperature operating limit) [°C] -10.0
Pdh (declared heating capacity) [kW] 6.20
COPd (declared COP) - 2.38
WTOL (Heating water Operation Limit) [°C] 55.0(F) Tbivalent temperature Tblv [°C] 2.00
Pdh (declared heating capacity) [kW] 3.40
COPd (declared COP) - 2.99
Capacity of the back-up heater integrated in the unit P back-up heater (@Tdesignh: –10°C) [kW] 27.0
Psup back-up heater (@Tdesignh: –10°C)
Supplementary capacity at P_design Psup (@Tdesignh: –10°C) [kW] 27.0
Productfiche Details and Precautions on installationProductfiche Energylabels and ProductfichesProduct Fiche DataAddress Line 1Address Line 2
EHYHBH08AAV3U /EVLQ08CAV3
XL
A++ A
6.90 kW6.40 kW
6.60 kW42 dB
62 dB
Model(s): EHYHBH08AAV3U / EVLQ08CAV3
Air-to-water heat pump: Yes
Water-to-water heat pump: no
Brine-to-water heat pump: no
Low-temperature heat pump: no
Equipped with a supplementary heater: Yes
Heat pump combination heater: Yes
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average, colder and warmer climate conditions.
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output (3) Prated 6.40 kW Seasonal space heating energyefficiency
ηs 127 %
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Declared coefficient of performance or primary energy ratio for part loadat indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7 °C Pdh 5.70 kW Tj = – 7 °C COPd orPERd
2.3895.2
– or %
Tj = + 2 °C Pdh 3.40 kW Tj = + 2 °C COPd orPERd
2.99120
– or %
Tj = + 7 °C Pdh 3.50 kW Tj = + 7 °C COPd orPERd
4.20168
– or %
Tj = + 12 °C Pdh 3.30 kW Tj = + 12 °C COPd orPERd
5.82233
– or %
Tj = bivalent temperature Pdh 3.40 kW Tj = bivalent temperature COPd orPERd
2.99120
– or %
Tj = operation limit temperature Pdh 6.20 kW Tj = operation limit temperature COPd orPERd
2.3895.2
– or %
For air-to-water heat pumps: Tj = – 15 °C(if TOL < – 20 °C)
Pdh kW For air-to-water heat pumps: Tj =– 15 °C (if TOL < – 20 °C)
COPd orPERd
– or %
Bivalent temperature Tbiv 2.00 °C For air-to-water heat pumps:Operation limit temperature
TOL -10.0 °C
Cycling interval capacity for heating Pcych kW Cycling interval efficiency COPcyc orPERcyc
– or %
Degradation co-efficient (4) Cdh 1.00 — Heating water operating limittemperature
WTOL 55.0 °C
Power consumption in modes other than active mode Supplementary heater
Off mode POFF 0.013 kW Rated heat output (4) Psup 27.0 kW
Thermostat-off mode PTO 0.006 kW Gas
Standby mode PSB 0.013 kW Type of energy input
Crankcase heater mode PCK 0.000 kW
Other items Inverter
Capacity control fixed/variable For air-to-water heat pumps:Rated air flow rate, outdoors
— 2,700 m3/h
Sound power level, indoors/outdoors LWA 62.0 /42.0
dB For water- or brine-to-water heatpumps: Rated brine or water flowrate, outdoor heat exchanger
— m3/h
Annual energy consumption QHE 4,0200.057
kWh orGJ
For heat pump combination heater:
Declared load profile XL Water heating energy efficiency ηwh %
Daily electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh
Annual electricity consumption AEC kWh Annual fuel consumption AFC GJ
Daikin Europe N.V. Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
(3) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of asupplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(4) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.