Download - termosystem tegola EN - termoisolanti tegola_EN.pdfTERMOSYSTEM TEGOLA Features Unit Code EPS 100 EPS 150 EPS 200 EPS 100 graphite Standard % DS(N) ± 5 ± 5 ± 5 ± 5 EN 1603 BS KPa

Transcript
Page 1: termosystem tegola EN - termoisolanti tegola_EN.pdfTERMOSYSTEM TEGOLA Features Unit Code EPS 100 EPS 150 EPS 200 EPS 100 graphite Standard % DS(N) ± 5 ± 5 ± 5 ± 5 EN 1603 BS KPa

TERMOSYSTEM TEGOLA

Features Unit Code EPS 100 EPS 150 EPS 200 EPS 100 graphite Standard

% DS(N) ± 5 ± 5 ± 5 ± 5 EN 1603

BS KPa 150 200 250 150 EN 12089

CS(10) KPa

CLASSIFICATION

100 150 200 100 EN 826

λD 0.036 0.034 0.034 0.031 EN 13163

E E E E EN 13501/1

MU µ 40-60 70-90 90-120 40-60 EN 12086

Dimensional stability inspecific temperature and humidity conditions

Bend resistance

Compression resistance at 10% crush risk

Factor of resistance to dimensionless water vapour diffusion

Thermal conductivity

Fire resistance European classification

Insulating waterproof system made up of the coupling of a sintered expanded polystyrene sheet in compliance with Standard EN 13163, specifically shaped to house planking suited to support the counterbatten to support the slate tiles, coupled with 3.5 kg/m2 sheathing, reinforced with polyester TNT and self-protected with slate components in compliance with Standard EN 13707. The panel is equipped with two continual overlapping selvages.DIMENSIONS: length 1,800 mm - width 1,000 mm - thickness from 40 to 120 mm

SINTERED EXPANDED POLYSTYRENE in compliance with EN 13163

ISOSYSTEM SRLVia dell’Artigianato, 25 - Ponte di Piave - Treviso - Italy

Tel. +39 0422 858070 - Fax +39 0422 759654www.termoisolanti.com - [email protected]

Classification F FFire performance

°C EN 1110 :1999°C UNI EN 1109 :1999

UNI EN 1928/B:2000

% EN 1107-1:1999

KPa

%

N50/mm UNI EN 12311-1:1999

UNI EN 12311-1:1999

N

110-5

± 0.3± 0.3

≥ 100

530

350

40

40

100

100

120-5

± 0.3± 0.3

≥ 200

550

400

40

40

100

100UNI EN 12310-1:1999

EN 13501-1 2005EN 11925-2

Flexibility when cool

Shape stability in presence of heat

Dimensional stabilityLongitudinalTransverse

Water resistance

Tensile strengthLongitudinal maximum load

Transverse maximum load

Elongation to ruptureLongitudinal

Transverse

Tear resistanceLongitudinal

Transverse

Description U. M.Polyester

STANDARDSmooth Aut. Min

TECHNICAL SPECIFICATIONS OF BITUMEN-BASEDELASTOPLASTOMERIC BEFORE COUPLING

Solid fir wood planks 50 x 40 x 1,000 mm placed with centre distance of 60 cm

WAR

NIN

GS:

The

info

rmat

ion

whi

ch fe

atur

es in

the

pres

ent t

echn

ical

spe

cific

atio

ns, p

rovi

des

a ge

nera

l des

crip

tion

of th

e pr

oduc

t. It

rem

ains

how

ever

the

role

and

res

pons

ibili

ty o

f the

use

r to

che

ck th

at th

e pr

oduc

t and

rel

ativ

e do

cum

enta

tion

are

suite

d to

the

part

icul

ar a

pplic

atio

n in

com

plia

nce

with

legi

slat

ion

and

stan

dard

s cu

rren

tly in

forc

e. IS

OSY

STEM

Srl

res

erve

s th

e ri

ght t

o, a

t an

any

mom

ent a

nd w

ithou

t for

ewar

ning

, mak

e an

y ty

pe o

f mod

ifica

tion,

incl

udin

g te

rmin

atio

n of

pro

duct

ion.

Sup

ply

is b

ased

upo

n ou

r pr

oduc

tion

capa

city

.