Download - Innovative testing device for water hammer strength of … of Single Container Water Hammer Tester Specifications Precautions 1. Testable Glass Bottle Neck Diameter : MIN.Φ21mm MAX.Φ54mm

Transcript
Page 1: Innovative testing device for water hammer strength of … of Single Container Water Hammer Tester Specifications Precautions 1. Testable Glass Bottle Neck Diameter : MIN.Φ21mm MAX.Φ54mm

Specifications of Single Container Water Hammer Tester

Specifications

Precautions

1. Testable Glass Bottle

Neck Diameter : MIN.Φ21mm  MAX.Φ54mm

           **For use of any dimension out of these dimensions, a consultation is required.

Weight : MAX.1300g

(containing closure + liquid content + glass bottle)

Bottle Height : MAX.400mm

Body Diameter : MAX.Φ85mm (without antiscattering cover: MAX.Φ105mm)

2. Supply Energy

Compressed Air (0.2 ~ 0.3Mpa)

1. The user shall always wear safety protective equipments (full-face mask and gloves) when he uses the tester

for protection from scattering glass.

2. The user shall take measures to prevent the hammer from dropping when he sets a glass bottle on the tester

under the hammer.

3. The user shall pay attention to around the tester, where glass may scatter during operation of the tester.

Single Container Water Hammer

Tester

Innovative testing device for

water hammer strength of glass containers

JPN PAT.No 4523631

Copyright © 2015 Toyo Glass Co., Ltd.

Overseas Business Department Production and Technology DivisionTEL: +81-3-4514-2068 FAX: +81-3-4514-2085Email : [email protected]

URL : http://www.toyo-glass.co.jp

Osaki Forest Bldg., 2-18-1 Higashi-Gotanda, Shinagawa-ku, Tokyo 141-0022, Japan

http://www.toyo-glass.co.jp

Air cylinder for hammer lifting Hammer

gripper

Pressure reducing valve

Gripper opening/closing valve

Falling energy setting gauge

Hammer lifting button

Bottle finish clamper

Bottle jacket

Wheel

Level adjuster

Level

Hammer

Bottle top position adjustment

Weight: approx. 120kg