Download - HTKSHekw FE180/PH90 E90 - BK EESTI

Transcript
Page 1: HTKSHekw FE180/PH90 E90 - BK EESTI

HTKSHekw FE180/PH90 E90

®

Fire resistant, halogen-free telecommunication cable

Temperature range:Fixed installation: -25°C up to 70°CMin. instalation temp: -5°C Operating voltage: 225VTest voltage:AC 1500 VDC 2250 VInsulation resistance (minimum): 500MΩ*kmPair loop resistance at 20°C (maximum):0,8 mm - 75 Ω/km1,0 mm - 48 Ω/km1,4 mm - 26,6 Ω/km1,8 mm - 14,96 Ω/km2,3 mm - 9,6 Ω/km2,8 mm - 6,4 Ω/kmMutual capacitance of pair at 1kHz (maximum): 150 nF/kmInductance: 0,7 mH/kmMin. bending radius: 10 x Ø

Cores: solid copper conductor class 1, acc. to PN-EN 60228Insulation: mica tape wrapping and halogen-free compoundCore colors: acc. to PN -92/T-90321Core arrangement: core twisted in pairs, pairs twisted together Wrapping: polyester tapeScreen: aluminium backed polyester type with tinned copper drain wire 0,4mm diaOuter sheath: halogen-free polymer compoundOuter sheath color: red

Fire resistant, halogen-free telecommunication cables designed for emergency lighting installations, alarm- , signalling-, and teletransmission systems, in sound alarm systems as well as in fire warning systems, fire automation and other safety ensuring installations. Static screen (St) protects the cable against interferences of external magnetic fields. Under fire conditions those cables ensure proper operation of installations for at least 90 minutes (PH90) and durability of conductors insulation for 3h (FE180). During burning cables do not emit corrosive gases or dense smoke. Cables are suitable for fixed installations inside buildings. HTKSHekw FE180/PH90 (E90) cables have been tested in accordance with the requirements of DIN 4102 p.12 and can be installed in E90 cable support systems as their elements (installation on clamps located every 30cm and 60cm).

- fire resistant- halogen-free- flame retardant

- no corrosive gases (acidity pH ≥ 4,3; conductivity < 10 μS/mm)- low smoke emission (light transmittance over 60%)- increased insulation resistance (FE180)- fire integrity function (PH90)- installation on clamps located every 60cm in E90 systems- low fire load (calorific value)

EN 60332-1

Br F

Cl

halogen-freeEN 60754

low smoke emissionEN 61034

EN 60332-3internal application

Technical data: Construction:

E90FE180 PH 90

insulation resistance

to fire 180min

E90 fire integrity function

PH90 fire integrity function

Flame propagation test for a single insulated cable: EN 60332-1, IEC 60332-1, VDE 0482-332-1Flame propagation test for vertically-mounted bunched cables: EN 60332-3-24, IEC 60332-3-24,VDE 0482-332-3-24Test on corrosive gases emitted during burning: EN 602754-2, IEC 602754-2, VDE 0482-754-2Smoke density emission during burning: EN 61034-2, IEC 61034-2, VDE 0482-1034-2Insulation resistance to long term fire exposure FE180: PN-IEC 60331-21, IEC 60331-21, VDE 0472-814Fire integrity function of cable support system E90: VDE 4102-12Fire integrity function of cable installation (PH90): EN 50200

Fir

e r

esis

tan

t cab

les

RoHS 2011/65/EU

LVD 2014/35/EU

RoHS

warranty

2 years

Application:

Tests:

Cable characteristics:

B10100B10118B10101B10102B10103B10119B10129B10120B10149B10104

B10148B10105B10106B10107B10122B10123B10124B10108B10126B10109

1x2x0,81x4x0,82x2x0,83x2x0,84x2x0,85x2x0,87x2x0,8

10x2x0,820x2x0,8

1x2x1,0

1x4x1,02x2x1,03x2x1,04x2x1,05x2x1,07x2x1,0

10x2x1,01x2x1,41x4x1,42x2x1,4

7,38,19,5

10,311,612,613,715,819,8

8,0

9,110,811,713,314,515,818,7

9,210,512,7

577888

109133155194254451

70

100113142176207263368

97148163

10,920,520,530,139,849,468,797,7

194,116,3

31,331,346,461,576,6

106,7151,9

30,760,360,3

sprinklers zone

2n x mm Cu[kg/km]

Cu[kg/km]

Cat. no.Outer

diameter [mm]

Approximate cable weight

[kg/km]Cat. no.

Outerdiameter

[mm]

Approximate cable weight

[kg/km]

2n x mm

Page 2: HTKSHekw FE180/PH90 E90 - BK EESTI

HTKSHekw FE180/PH90 E90

B10127B10128B10116B10130B10131B10110B10133B10111B10134B10135B10136B10137

B10138B10112B10140B10113B10141B10142B10143B10144B10145B10150B10151B10152

3x2x1,44x2x1,45x2x1,47x2x1,4

10x2x1,41x2x1,81x4x1,82x2x1,83x2x1,84x2x1,85x2x1,87x2x1,8

10x2x1,81x2x2,31x4x2,32x2x2,33x2x2,34x2x2,35x2x2,37x2x2,3

10x2x2,31x2x2,81x4x2,82x2x2,8

13,915,917,319,522,610,011,514,015,317,619,621,6

25,611,413,216,117,720,922,925,630,412,614,618,5

212268320433582123194212282360451590

827166275296403538649884

1239216368410

89,8119,4148,9208,0296,6

50,098,998,9

147,7196,5245,4343,0

489,580,9

160,7160,7240,4320,1399,9559,3798,5119,4237,5237,5

®

Fir

e r

esis

tan

t cab

les

Fire resistant, halogen-free telecommunication cable

2n x mm Cu[kg/km]

Cu[kg/km]

Cat. no.Outer

diameter [mm]

Approximate cable weight

[kg/km]Cat. no.

Outerdiameter

[mm]

Approximate cable weight

[kg/km]

2n x mm

Cable Factory BITNER reserve the right to modify specifications without prior notificationNote: On customer's request other cross sections or number of cores can be produced