X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand...

56
X- & γ-ray Instrumentation and everything else

Transcript of X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand...

Page 1: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

X- & γ-ray Instrumentation and everything else

Page 2: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The Dark Ages

Used nuclear physics detectors Proportional Counters Scintillators Simple collimators HEAO A1 & A2: 2 x 8 degree field of view Confusion limit is about 200 sources over whole sky Or more complex ones Modulation collimator, e.g. HEAO A3 – resolution of a few arcmin within a 4 degree field Coded masks

Page 3: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

X-ray instruments are strongly affected by the necessity to use grazing incidence reflection.

Imaging has been revolutionary

Page 4: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Wolter Telescopes provide the usual gains we expect from telescopes in the optical, infrared, and radio.

They consist of conic sections but operate at grazing incidence.

They are hopelessly in violation of the Abbe Sine Condition.

Page 5: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

On-axis they provide good images (this is for Chandra).

Page 6: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Corrective optics are not feasible, so the off-axis images degrade quickly as the field angle increases.

Page 7: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

AXAF CCD Imaging

Spectrometer (ACIS)

Ten 1024 X 1024 CCDs Frame transfer readout Read out every 41msec Quantum yield: 1 electron/3.6eV

The Basic Chandra Focal Plane Instrument

Page 8: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

CCDs give good results from about 0.6 to 10 keV. a = back illuminated, b = front illuminated,

c = deep depletion, d = pn CCD

Page 9: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The Galactic Center

Page 10: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The CCDs are capable of limited energy resolution.

These pre-launch predictions are a factor of 2 – 3 optimistic because of damage to the CCDs by cosmic rays on orbit.

Page 11: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Constructive interference for sin2dm

Bragg diffraction provides better spectral resolution. Uses the structure of a crystal as the diffraction grating

Therefore, for d = 2 X 10-4 mm, at 10 kev (1 X 10-4 mm), m = 1 = 15o

Page 12: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less
Page 13: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The High Energy Transmission Grating (HETG) for Chandra

Page 14: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The grating has a medium energy (outer rings) and a high energy section (inner rings). Each consists of a series of very tiny gold bars. The gold is partially transparent to the x-rays and has a refractive index < 1 so the arrangement induces phase shifts just as other gratings do. For spectroscopy, the grating is moved in front of the detector CCDs to disperse the light onto the ACIS-S array.

Page 15: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Some HETG parameters Spectral resolution: up to 1000 Grating period (HEG): 2 X 10-4 mm Collecting area: ~ 30 cm2, energy dependent Chandra ~ 500 cm2

Efficiency: ~ 5 - 10% To right, spectrum of NGC 3783

Page 16: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

For reflecting surfaces, Chandra and XMM-Newton used single materials (e.g., platinum, iridium, gold) in grazing incidence. This approach drops rapidly in efficiency (or equivalently works only at more and more grazing incidence) with increased energy and is not effective above about 10 kev. Higher energy photons can be reflected using the Bragg effect. Two layers alternate in material between high and low density, high and low index of refraction (e.g., tungsten or platinum for high, silicon or carbon for low). The stack (up to 200 layers) acts like a crystal lattice and reflects by constructive interference. With identical layers, the reflection would be over a restricted energy range; by grading the layers, broad ranges are reflected. The top layers have large spacing (d) and reflect the low energies, while lower layers have smaller d for higher energies. NuStar (launched June 13, 2012) uses this approach to make reflecting optics working up to 79eV. It will use a standard Wolter design with multilayer surfaces deposited on thin glass substrated, slumped to the correct shape. It has 130 reflecting shells, with a focal length of 10 meters. The telescope was deployed after launch so the spacecraft would fit within the launch constraints.

High Energy Reflecting Optics

Page 17: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

How the mirrors work in NuStar

Page 18: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Reflectivity of a graded layer surface.

Page 19: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

NuStar on orbit (artist’s concept)

Page 20: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Collecting area comparison:

Page 21: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

NuStar Parameters

Energy Range: 6 - 79 keV Angular Resolution: 46 arcsec (HPD) FOV: 12 x 12 arcmin Spectral Resolution: 1.25 KeV at 68 keV Timing Resolution: 1 ms ToO response: < 48 hours Launch date: June 13, 2012 Orbit: 550 km x 600 km, 6 degree inclination

Page 22: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Each of the two NuStar telescopes has four 32 X 32 CdZnTe detector arrays at its focus. These detectors can provide spectral resolution of about 100 through the

pulse height from a detected X-ray (similar to CCDs at smaller energies). The high atomic weight materials absorb x-rays effectively and by adjusting the relative amounts of Cd and Zn, the band gap can be tailored to the desired

operating temperature.

Each pixel is about 605mm, and each 32 X 32 pixel array is about 2 cm on a side. The readout uses a custom integrated circuit (ASIC). Each pixel is attached by flip chip hybridization (similar to the construction of an infrared direct hybrid array).

Page 23: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Energy resolution of a prototype NuStar detector array:

Page 24: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Background particles that do not pass through the telescope are detected by an active shield of CsI surrounding the focal plane. When it triggers, the

output of the focal plane array is rejected.

Page 25: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less
Page 26: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Microcalorimeters can provide high resolution X-ray spectra

Microcalorimeters: bolometers can be built to absorb X-rays. If the heat capacity is very low and the response fast, a single absorbed X-ray results in a "pulse" on the output, and the size of the pulse is proportional to the energy of the X-ray (remember, bolometers detect anything they absorb!). Figures below from Wollman et al., NIST:

Page 27: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Compared with other imaging detectors (e.g., CCDs), the spectral resolution is fantastic

Page 28: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Prototype microcalorimeter arrays demonstrate resolution equivalent to R = 1000 – 3000. This is achieved without grating inefficiencies and with full imaging information.

Page 29: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The International X-ray Observatory (IXO) was planned to make optimum use of hard X-ray optics and microcalorimeters

It got very ambitious ($$$$, complexity) and has been cancelled.

Page 30: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Prototyped IXO mirror development

Page 31: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Parameter Value Mirror Effective Area 3 m2 @ 1.25 keV 0.65 m2 @ 6 keV 150 cm2 @ 30 keV Spectral Resolution (FWHM), DE = 2.5 eV 2 arcmin 0.3– 7 keV FOV, bandpass DE = 10 eV 5 arcmin 0.3–10 keV DE = 150 eV 18 arcmin 0.1–15 keV E/DE = 3000 point src 0.3– 1 keV Angular Resolution 5 arcsec HPD 0.1– 7 keV 30 arcsec HPD 7–40 keV Instruments: XMS X-ray Microcalorimeter Spectrometer XPOL X-ray Polarimeter XGS X-ray Grating Spectrometer WFI/HXI Wide Field Imager similar to ACIS, but uses active pixel sensors, similar to CMOS or IR array readout architecture – amplifier for each pixel, so no damage to charge transfer efficiency. HXI is a Hard X-ray Imager based on CdTe detectors. HTRS High Time Resolution Spectrometer

International X-ray Observatory Parameters

Page 32: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

ATHENA • IXO has been resurrected as the Advanced Telescope for High Energy Astrophysics (ATHENA) by ESA. It has been selected as a second large mission of the ESA Cosmic Vision program. • Launch is planned for 2028 • X-IFU utilizes an array of cryogenically cooled microcalorimeter transition edge sensors operating over the range of 0.2-12 keV. The total field of view is 5 arcmin. •The Wide Field Imager (WFI) utilizes five arrays of p-channel field-effect transistors operating over a range of 0.1-15 keV. The central array has a 256 X 256 pixels and a field of view 7.5 arcmin. Four outer arrays have a format of 448 X 640 pixels and a field of view 40 arcmin.

• p-channel FETs can be built so ionizing particles in the substrate create free electrons that collect close to the channel and therefore modulate the channel current.

Page 33: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

ATHENA mirror must meet demanding goals for collecting area. This requires a huge reduction in mass density of the mirror material while

retaining high accuracy for good imaging.

Page 34: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The solution is to make a standard Wolter telescope using thin plates of silicon (170mm thick), called “silicon pore optics”. Figure from Beijersbergen et al. (2004)

Page 35: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less
Page 36: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Gamma Ray Telescopes Based on detection of particle showers

The particles in the shower are highly relativistic

Page 37: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Fermi Gamma Ray Satellite

Page 38: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Fermi Large Area Telescope (LAT)

Covers about 20% of sky, angular resolution about 0.2o

Page 39: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Principle of Operation of the LAT

• There is a multi-layer stack of “converters” consisting of thin tungsten foils, and detectors • If the detectors are triggered and the veto counters are not, then the triggering particle does not have electrical charge and is most likely a gamma ray • It can produce electron-positron pairs in the converter foils, and their direction is measured by the detectors to determine the direction of the gamma ray • The gamma ray is absorbed in scintillators after the tracker, to determine its energy

Page 40: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

• The position-sensitive detectors are layers of silicon with electrode strips • An energetic charged particle ionizes some of the silicon and an electrical pulse is picked up by the strips

• The calorimeter is a stack of scintillator “bricks” that have high atomic number, hence are highly absorbing. • The absorbed energy produces light that is detected by photomultipliers

Page 41: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Tev Gamma Ray Telescopes Based on detection of air showers

The particles in the shower are highly relativistic and emit Cherenkov light as they penetrate the atmosphere. An optical receiver will detect a burst of light (about 3

nsec in width)

Page 42: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Here is the first such large receiver, on Mount Hopkins

Page 43: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Modern facilities use a number of such telescopes separated by 100m or so. This helps distinguish the gamma ray showers from the nuclear ones.

Page 44: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Two major facilities are in operation: HESS in Namibia (to right) and VERITAS in Arizona (below)

Page 45: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The breakthrough that has made this field successful is to use imaging focal planes and multiple telescopes to isolate the gamma-ray showers. Because the gamma rays

are less penetrating, their showers peak higher in the atmosphere than those of protons and other cosmic rays. Their images are therefore more confined, and

whereas local single muons also produce confined images they can be screened out because they are seen only by single telescopes. Each VERITAS telescope has an array

of 499 photomultipliers to image the showers. Gaps between the PMTs are filled with light cones. Here are some of the light cones shown over the full PMT array.

Page 46: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

An example: TeV variability of the Blazar Mrk 421

Page 47: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Imaging is relatively low resolution Color is HESS (gamma ray) and contours are ASCA (X-ray) of shell-type supernova

Page 48: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Laser Interferometer Gravitational Wave Observatory (LIGO)

Page 49: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less
Page 50: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

The first detection!!

Page 51: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Cosmic Rays: The Pierre Auger Observatory

Page 52: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

• An energetic cosmic ray produces an air shower of particles • They spread enough to be detected by multiple units on the ground • In addition, they excite fluorescence in the upper atmosphere • This is also detected by systems that look out over the ground-based detectors

Page 53: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Ice Cube Neutrino Detector Laboratory

Page 54: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less
Page 55: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

Portrait of “Ernie”, a 1015 eV Neutrino Ernie interacted with an atom in the ice and created a shower of particles. Since they are relativistic, they emit Cherenkov light as they pass through the ice. This light is detected by the DOMs and from the timing it is concluded that the particle responsible for them (Ernie) was moving upward, i.e., passed through the earth.

Page 56: X- & γ-ray Instrumentation and everything elseircamera.as.arizona.edu/Astr_518/xray_2016.pdfand multiple telescopes to isolate the gamma-ray showers. Because the gamma rays are less

End of Course!!